instruction stringlengths 150 245 | output stringclasses 28
values |
|---|---|
Consider the scope on Replace/Scrap in the functional location CLV/FPSOH/WAT/WFLT /HU-TSV-51924, the given unit name of COARSE FILTER A OUTLET THERMAL SAF VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on DAL/6-PSV-21226B-Révision in the functional location DAL/FPSOT/GAS/FLARE/6-PSV-21226B, the given unit name of PRES. SAFETY VALVE, LP FLARE PUMP OUTLET, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOH/COF/CHEM /IPN-_HI-HU75-01-_03, the given unit name of Hydrate inhibitor piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Intrusive Major Insp. VII in the functional location CLV/FPSOT/OIL/SEP /TO-ES-2010B, the given unit name of CRUDE OIL HEATER/COOLER B, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on Non-Intrusive Major inspection in the functional location GIR/FPSOT/ELE/PWG /IPN-CW-_460-01-B561, the given unit name of PIPING GROUP POWER GENERATION, the corresponding item class discipline would be | Piping |
Consider the scope on PROD-LOOP-P80 - Int Pigging / 24M in the functional location GIR/SUB-R/EXT/EWELL/PROD-LOOP-P80, the given unit name of PRODUCTION LOOP, the corresponding item class discipline would be | Intelligent Pigging |
Consider the scope on Insp Group Line IPN-_FS-0621-38-B513 in the functional location DAL/FPSOT/GAS/FLARE/IPN-_FS-0621-38-B513, the given unit name of LINE GROUP,FLARE,FLARES,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/OIL/SEP /IPN-_HL-TO20-02-B03, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Major Non Intrusive Insp EC913 in the functional location GIR/FPSOT/COF/INWAT/EC913, the given unit name of UB919-OSMOSE WATER HEATER (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on DAL/6-PSV3-31122-Révision in the functional location DAL/FPSOT/EXT/TRANS/6-PSV3-31122, the given unit name of PRES. SAFETY VALVE, ON PROD. HEADER, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on FB203-Remote Int. Inspection_VIE in the functional location GIR/FPSOT/GAS/FLARE/FB203-FLARE-HP, the given unit name of TORCHE HP, the corresponding item class discipline would be | Flare TIP |
Consider the scope on FI Visual Inspection of complete struct. in the functional location CLV/FPSOT/HSG/STRUC/R147-SEC_STR, the given unit name of Secondary structure of R147 Piperack, the corresponding item class discipline would be | Structure |
Consider the scope on Non Intrusive Major Inspection_MNT in the functional location CLV/FPSOH/CRS/HVAC /HU-IF-092601, the given unit name of CIRCUIT 1 CARTRIDGE FILTER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on SCD + External damage major inspection in the functional location PAZ/FPSOT/GAS/TRANS/IPN-_HG-TO34-14-D49, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Overhaul in the functional location CLV/FPSOT/CRS/AIR /TO-PSV-07202B, the given unit name of INSTR. AIR RECEIVER B PRESS. SAF. VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Major Non Intrusive Insp DA895B in the functional location GIR/FPSOT/COF/INERT/DA895-B, the given unit name of NITROGEN STORAGE DRUM (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/EXT/EWELL/IPN-_NH-0630-95-F513, the given unit name of LINE GROUP,OIL RAW,OIL,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on TANKER CHAFFING CHAIN SB/WEAR MEASUR in the functional location DAL/BUOY /OIL/LOAD /SB CHAFF MOOR TANKER, the given unit name of SB CHAFFING MOORING TANKER SIDE, the corresponding item class discipline would be | FU Items |
Consider the scope on DAL/6-PSV-21801-Révision in the functional location DAL/FPSOT/GAS/FLARE/6-PSV-21801, the given unit name of PRES. SAF. VALVE, HULL GAS VENT BLOWER, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on CLASS PSV-GIR/41-PSV-0130-Révision in the functional location GIR/FPSOT/OIL/STORE/41-PSV0130, the given unit name of TA013 SOUPAPE DE SECURITE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Replace/Scrap in the functional location PAZ/FPSOH/COF/COOLW/HU-TSV-76106A, the given unit name of S.W OUTLET THERMAL SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Non-Intrusive Intermediate Inspection in the functional location PAZ/FPSOT/WAT/WFLT /TO-VF-5120B, the given unit name of CIP/EFM FILTER FILTER UNIT, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/OIL/SEP /IPN-_NW-0631-13-C513, the given unit name of LINE GROUP,OIL 1ST,WATER,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/WAT/WINJ /IPN-AV-_454-13-B630, the given unit name of PIPING GROUP WATER INJECTION, the corresponding item class discipline would be | Piping |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/COF/FG /IPN-_FG-TO70-07-D03, the given unit name of Fuel gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on VII in the functional location PAZ/FPSOT/OIL/OWAT /TO-VF-2712, the given unit name of O9 PRODUCED WATER DESANDING FILTER UNIT, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on Major Non Intrusive Inspection 6-DA-1910 in the functional location DAL/FPSOT/COF/CHEM /6-DA-1910, the given unit name of METHANOL STORAGE VESSEL, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/GAS/COMP /IPN-_HG-TO31-14-H21, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on External damage major inspection in the functional location CLV/FPSOT/EXT/EWELL/IPN-_HC-TO10-19-H03, the given unit name of Hydrocarbon Gas/Liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on SCD + External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-63-G600, the given unit name of LINE GROUP,HP GAS,GAS,SS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on M1-Visual inspection of tertiary struc in the functional location GIR/FPSOT/HSG/STRUC/MOD M1, the given unit name of STRUCTURAL MODULE M1, the corresponding item class discipline would be | Structure |
Consider the scope on UTC + External damage major inspection in the functional location CLV/FPSOT/CRS/FWAT /IPN-_FW-TO01-02-_92, the given unit name of Fire water piping group, the corresponding item class discipline would be | Piping |
Consider the scope on FPSO DECK/TEPA GVI in the functional location DAL/FPSOH/HSG/STRUC/DECK, the given unit name of DALIA FPSO-DECK, the corresponding item class discipline would be | FU Items |
Consider the scope on PAZ/BUOY COMPART_INTRUSIVE in the functional location PAZ/BUOY /HSG/STRUC/COMP-21, the given unit name of PAZ STRUTURAL COMPARTMENT, the corresponding item class discipline would be | FU Items |
Consider the scope on Non Intrusive Major Insp. in the functional location CLV/FPSOH/HSG/UPWAT/HU-VZ-8532A, the given unit name of BRACKISH WATER MEMBRANE VESSEL, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/FLARE/IPN-_FS-0621-29-B513, the given unit name of LINE GROUP,FLARE,FLARES,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/GAS/COMP /TO-PSV-31603A, the given unit name of GAS LIFT COOLER PRESS. SAFETY VALVE A, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on SCD + External damage major inspection in the functional location DAL/FPSOT/OIL/SEP /IPN-_GH-0631-04-C513, the given unit name of LINE GROUP,OIL 1ST,OILY EFLUENT,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on PSV-751542-Replace/Scrap PSV in the functional location PAZ/FPSOT/COF/CHEM /TO-PSV-751542, the given unit name of PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Intrusive Major Inspection in the functional location PAZ/FPSOT/CRS/AIR /TO-VA-0701A-1, the given unit name of DESICCANT VESSEL AIR INSTRUMENT CYLINDER, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0656-30-G513, the given unit name of LINE GROUP,GAS LIFT,GAS,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on Non Intrusive Major Inspection_MNT in the functional location CLV/FPSOT/OIL/OWAT /TO-EA-2711C2, the given unit name of P.W. BOOSTER PUMP C SEAL SYSTEM COOLER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on HU-TR-8632A2 FU/TEPA GVI Intermed. insp. in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8632A2, the given unit name of NO1 STBD FWD WATER BALLAST TANK_WBT 1SF, the corresponding item class discipline would be | FU Items |
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/GAS/FLARE/IPN-_FH-TO36-01-B23, the given unit name of High pressure flare piping group, the corresponding item class discipline would be | Piping |
Consider the scope on PAZ-FLOR_X-RAY YEARLY CAMPAIGN in the functional location PAZ/FPSOT, the given unit name of PAZFLOR Topsides, the corresponding item class discipline would be | Campaign |
Consider the scope on CLV/TO-V-35687 FLAME ARRESTOR in the functional location CLV/FPSOH/OIL/STORE/TO-V-35687, the given unit name of FLAME ARRESTOR, VENT COT_2P, HU-TR-2412, the corresponding item class discipline would be | Flame Arrestor |
Consider the scope on Replace/Scrap 6-TSV-41504B1 in the functional location DAL/FPSOT/COF/INWAT/6-TSV-41504B1, the given unit name of THERM. SAFETY VALVE, ON SAND ACCUMULATOR, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-50-D511, the given unit name of LINE GROUP,HP GAS,GAS,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on Non Intrusive Major Inspection in the functional location GIR/FPSOT/CRS/AIR /DS831C, the given unit name of KX830C-AIR/ WATER SEPARATOR (V), the corresponding item class discipline would be | Lifting |
Consider the scope on GIR-Visual Inspection and Function Test in the functional location GIR/FPSOT/COF/LIFT, the given unit name of LIFTING, the corresponding item class discipline would be | Lifting |
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOH/OIL/OWAT /IPN-_PW-HU27-01-B03, the given unit name of Produced water piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Intrusive major inspection in the functional location GIR/FPSOH/OIL/DRAIN/BILGE WELL AFT STBD, the given unit name of BILGE WELL MACHINERY SPACE TANK TOP, the corresponding item class discipline would be | FU Items |
Consider the scope on Major Non Intrusive Insp EC602B in the functional location GIR/FPSOT/GAS/DEHYD/EC602B, the given unit name of TEG COOLER (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Insp Group Line IPN-_DF-0637-56-F513 in the functional location DAL/FPSOT/OIL/DRAIN/IPN-_DF-0637-56-F513, the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on CLV/IPN-_HL-TO254 - External insp. + NDT in the functional location CLV/FPSOT/GAS/FLARE/IPN-_HL-TO36-32-B03, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Major Non Intrusive Insp + UTC in the functional location PAZ/FPSOH/CRS/AIR /HU-VA-0702, the given unit name of HULL INSTRUMENT AIR CYLINDER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/CRS/AIR /TO-PSV-079392, the given unit name of HP SUPPLY PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 5-TA-8170/FU Tank Intermediate Survey in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8170, the given unit name of NO.7 WATER BALLAST TANK (P), the corresponding item class discipline would be | FU Items |
Consider the scope on Non Intrusive Major Inspection_MNT in the functional location CLV/FPSOT/ELE/PWG /TO-VF-6011A1B, the given unit name of LIQUID FUEL FILTER 2A, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Inspection-DAL-DOUBLE-BOTTOM-TK-AFT in the functional location DAL/FPSOH/HSG/STRUC/DOUBLE-BOTTOM-TK-AFT, the given unit name of DOUBLE BOTTOM TANK, the corresponding item class discipline would be | FU Items |
Consider the scope on Major Non Intrusive Insp 6-DS-5201B in the functional location DAL/FPSOT/GAS/COMP /6-DS-5201B, the given unit name of SEAL GAS SCRUBBER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Non-Intrusive Major inspection in the functional location CLV/FPSOT/OIL/DRAIN/IPN-_CD-TO28-14-H23N, the given unit name of Closed drain piping group, the corresponding item class discipline would be | Piping |
Consider the scope on TA044/COR CP Measurement in the functional location GIR/FPSOH/HSG/STRUC/TA044, the given unit name of WATER BALLAST 6 STARBOARD (T), the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on BP_PS-FWD Visual insp.complete str*INAC* in the functional location PAZ/FPSOH/HSG/STRUC/BOATLANDING PORT FWD, the given unit name of BOATLANDING PLATFORM PORTSIDE FWD, the corresponding item class discipline would be | FU Items |
Consider the scope on TA049/FU Tank Class Survey in the functional location GIR/FPSOH/HSG/STRUC/TA049, the given unit name of WATER BALLAST 3 PORTSIDE (T), the corresponding item class discipline would be | FU Items |
Consider the scope on 5-PSV-17006D Replace/Scrap in the functional location DAL/FPSOH/CRS/FWAT /5-PSV-17006D, the given unit name of PRES. SAF. VALVE, ON GROSS TANK, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on CLV/TOVF5110C-Non Intrusive Major Insp in the functional location CLV/FPSOT/WAT/WFLT /TO-VF-5110C, the given unit name of SEA WATER COARSE FILTER C, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on FI Visual Inspection of complete struct. in the functional location CLV/FPSOT/HSG/STRUC/R142-SEC_STR, the given unit name of Secondary structure of R142 Piperack, the corresponding item class discipline would be | Structure |
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOH/OIL/OWAT /IPN-_TM-HU27-02-_03, the given unit name of Tank measuring piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Third Topside P11 Structure Inspection in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P11-PRM-STR, the given unit name of MODULE P11,TOPSIDE PRIMARY STRUCTURE, the corresponding item class discipline would be | Structure |
Consider the scope on BV tasks & intrusive major inspection in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8609B, the given unit name of PORT CENTRAL BALLAST 2P, the corresponding item class discipline would be | FU Items |
Consider the scope on DAL/Lifting Campaign in the functional location DAL/FPSOH/COF/LIFT, the given unit name of LIFTING EQUIPMENT, the corresponding item class discipline would be | Campaign |
Consider the scope on Overhaul in the functional location PAZ/FPSOT/COF/HEATL/TO-TSV-72012B, the given unit name of OUTLET TO DRIP PAN THERMAL SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/GAS/COMP /IPC-_HG-TO31-22-H21, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/OIL/SEP /IPN-GH-_420-09-B511, the given unit name of PIPING GROUP OIL SEPARATION, the corresponding item class discipline would be | Piping |
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/GAS/DEHYD/TO-PSV-30101A2, the given unit name of GLYCOL COOLER A PRESS. SAF. VALVE A2, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on SCD + External damage major inspection in the functional location GIR/FPSOT/GAS/COMP /IPN-NC-_431-55-E513S, the given unit name of PIPING GROUP GAS COMPRESSION, the corresponding item class discipline would be | Piping |
Consider the scope on Non intrusive major 2-DA-1003 in the functional location DAL/FPSOT/CRS/CONT /2-DA-1003, the given unit name of NITROGEN PRECHARGE ACCUMULATOR, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/OIL/DRAIN/IPN-_DF-0637-41-C513, the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-44-E511, the given unit name of LINE GROUP,HP GAS,GAS,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on Scrap/Replace 6-PSV-11508D in the functional location DAL/FPSOT/CRS/AIR /6-PSV-11508D, the given unit name of PRES. SAFETY VALVE, TO WET AIR RECEIVER, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Non-Intrusive Intermediate Inspection in the functional location PAZ/FPSOT/GAS/COMP /TO-VF-3170A2, the given unit name of ROOTS BLOWER A SILENCER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Overhaul in the functional location CLV/FPSOT/GAS/COMP /TO-PSV-31703B, the given unit name of PRESSURE SAFETY VALVE B, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on COR - WBFPTP - CP Measurement in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8100, the given unit name of FORE PEAK TANK (P), the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on Intrusive Major Inspection in the functional location PAZ/FPSOH/CRS/FWAT /HU-TZ-0121B, the given unit name of HIGH EXPANSION FOAM BLADDER TANK B, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on MACH SPACES DECK FLOOR GVI in the functional location DAL/FPSOH/HSG/STRUC/MACHINERY SPACES, the given unit name of MACHINERY SPACES/FU Class Survey, the corresponding item class discipline would be | FU Items |
Consider the scope on PSV-Replace/Scrap in the functional location PAZ/FPSOH/OIL/OWAT /HU-PSV-07271A, the given unit name of MR P/S BILGE WELLS PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Non Intrusive Major Inspection_MNT in the functional location CLV/FPSOH/CRS/SAFE /HU-TZ-0202C, the given unit name of HPU OIL TANK, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on CLV/FPSOT-12 Monthly DeadL Radio Survey in the functional location CLV/FPSOH, the given unit name of nan, the corresponding item class discipline would be | Campaign |
Consider the scope on FI Visual Inspection of complete struct. in the functional location CLV/FPSOA/HSG/STRUC/TELECOM_MAST-PRM_STR, the given unit name of Primary structure of TELECOM MAST, the corresponding item class discipline would be | Structure |
Consider the scope on Overhaul in the functional location PAZ/FPSOH/CRS/AIR /HU-PSV-07042, the given unit name of AIR GENERATION PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Overhaul in the functional location PAZ/FPSOT/OIL/STAB /TO-PSV4-21044B, the given unit name of TO LP FLARE PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Non-Intrusive Intermediate Inspection in the functional location PAZ/FPSOT/GAS/FLARE/TO-V_-3620, the given unit name of LP FLARE K.O. DRUM, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/COF/CHEM /IPN-_DF-0619-03-G580, the given unit name of LINE GROUP,METHANOL,DRAIN,SS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on GIR/41-PSV2-5077A-Echange Standard in the functional location GIR/FPSOT/GAS/COMP /41-PSV2-5077A, the given unit name of KY511A SOUPAPE SECURITE REFOUL., the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Non-Intrusive Intermediate Inspection in the functional location PAZ/FPSOH/COF/COOLW/HU-V_-7605, the given unit name of HULL C.W EXP DRUM, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Prim.& Sec. Topside P34 Structure Insp. in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P34, the given unit name of P34 Structural Module, the corresponding item class discipline would be | Structure |
Consider the scope on CLV/TOVC3020A - Non Intrusive Maj. Insp. in the functional location CLV/FPSOT/GAS/DEHYD/TO-VC-3020A, the given unit name of STILL COLUMN, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Major Non Intrusive Insp DA894A in the functional location GIR/FPSOT/COF/INERT/DA894-A, the given unit name of NITROGEN STORAGE DRUM (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Major Non-Intrusive Inspection + UTC in the functional location CLV/FPSOH/CRS/AIR /HU-TZ-0730B, the given unit name of COMPRESSOR A LUBE OIL RESERVOIR, the corresponding item class discipline would be | Non Structural Tank |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.