Consider the scope on SCD + External damage major inspection in the functional location PAZ/FPSOT/GAS/TRANS/IPN-_HG-TO34-12-H49P, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be
Piping
Consider the scope on DAL/BUOY COMPART_INTRUSIVE in the functional location DAL/BUOY /HSG/STRUC/COMP WBT2, the given unit name of BUOY TANK COMPARTMENT 02_WBT, the corresponding item class discipline would be
FU Items
Consider the scope on External damage major inspection in the functional location PAZ/FPSOH/COF/HTOIL/IPN-_LO-HU73-01-_03C, the given unit name of Lube oil piping group, the corresponding item class discipline would be
Piping
Consider the scope on VISUAL INSPECTION L2-BALCONY TER_STR in the functional location PAZ/FPSOH/HSG/STRUC/BALCONIES L2, the given unit name of STRUCTURE OF BALCONIES L2, the corresponding item class discipline would be
Structure
Consider the scope on First Topside-P21 Structure Inspection in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P21-PRM-STR, the given unit name of MODULE P21,TOPSIDE PRIMARY STRUCTURE, the corresponding item class discipline would be
Structure
Consider the scope on UTC + External damage major inspection in the functional location GIR/FPSOT/GAS/FLARE/IPN-NW-_436-19-B511, the given unit name of PIPING GROUP GAS FLARE, the corresponding item class discipline would be
Piping
Consider the scope on CLV/FPSOT/TO-JA-7830A/HYDR/6M in the functional location CLV/FPSOT/COF/LIFT /TO-JA-7830A, the given unit name of PEDESTAL CRANE, the corresponding item class discipline would be
Lifting
Consider the scope on DAL/6-PSV2-31122-Révision in the functional location DAL/FPSOT/EXT/TRANS/6-PSV2-31122, the given unit name of PRES. SAFETY VALVE, ON PROD. HEADER, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Visual inspection of tertiary struc in the functional location CLV/FPSOT/HSG/STRUC/M114, the given unit name of M114 STR Module PANCAKE FOR WELL FLUIDS, the corresponding item class discipline would be
Structure
Consider the scope on Scrap/Replace in the functional location PAZ/FPSOH/CRS/HVAC /HU-PSV-09002, the given unit name of HULL CHILLED WATER PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Non-Intrusive Major Inspection in the functional location PAZ/FPSOH/CRS/FWAT /HU-VB-0101B1, the given unit name of AIR START GAS VESSEL B1, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Overhaul in the functional location PAZ/FPSOT/OIL/SEP /TO-PSV-20182, the given unit name of TO HP WARM FLARE PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_DF-0637-98-E513, the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Replace/Scrap in the functional location CLV/FPSOH/OIL/OWAT /HU-PSV-27859A, the given unit name of SLOP WATER HEATER A PRESS. SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Major Non Intrusive Insp DA450 in the functional location GIR/FPSOT/OIL/OWAT /DA450, the given unit name of WATER BUFFER DEGASSING DRUM (V), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/EXT/EWELL/IPN-_NH-0630-22-D513, the given unit name of LINE GROUP,OIL RAW,OIL,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on BV tasks & intrusive major inspection in the functional location PAZ/FPSOH/OIL/DRAIN/HU-T_-2801B, the given unit name of STARBOARD SLOP TANK, the corresponding item class discipline would be
FU Items
Consider the scope on PROD-LOOP-P50 - Int Pigging / 36M in the functional location GIR/SUB-G/EXT/EWELL/PROD-LOOP-P50, the given unit name of PRODUCTION LOOP, the corresponding item class discipline would be
Intelligent Pigging
Consider the scope on Insp Group Line IPN-_DF-0637-92-D513 in the functional location DAL/FPSOT/GAS/COMP /IPN-_DF-0637-92-D513, the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/GAS/DEHYD/TO-PSV-30242B1, the given unit name of CART. FILTER B1 INLET PRESS. SAFE. VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on CLV/HULL_POTENTIAL MEASUREMENT in the functional location CLV/FPSOH/HSG/CATPR, the given unit name of Cathodic protection, the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on Insp Group Line IPN-_DF-0652-04-F513 in the functional location DAL/FPSOT/GAS/COMP /IPN-_DF-0652-04-F513, the given unit name of LINE GROUP,HP GAS,DRAIN,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on GIR/41-PSV-7772A-Replace/Scrap in the functional location GIR/FPSOT/OIL/OWAT /41-PSV7772A, the given unit name of SOUPAPE DE SURETE, SORTIE SANDCYCLONE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on COR - APT_P_CP Measurement in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8632D, the given unit name of NO4 STARBOARD WATER BALLAST TANK_WBT 4S, the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on Overhaul in the functional location CLV/FPSOT/WAT/WINJ /TO-PSV-54206B1, the given unit name of TO-P_-5420B OUTLET PRESS SAFETY VALVE B1, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Pre-Pop test, overhaul & recalibration in the functional location CLV/FPSOH/COF/CHEM /HU-PVSV-75111A, the given unit name of HU-TR-7550A PRESSURE VACUUM SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Major Non-Intrusive Inspection + UTC in the functional location CLV/FPSOT/GAS/COMP /TO-TZ-3140A-1, the given unit name of HP2/HP3 COMP. A LUBE OIL RESERVOIR, the corresponding item class discipline would be
Non Structural Tank
Consider the scope on TANKER MOORING HAWSER PS/WEAR MEASUR in the functional location DAL/BUOY /OIL/LOAD /MOOR Q REL HOOK PS, the given unit name of BUOY MOORING HAWSER Q RELEASE HOOK PS, the corresponding item class discipline would be
FU Items
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/COF/FG /IPN-_FG-TO70-15-F01, the given unit name of Fuel gas piping group, the corresponding item class discipline would be
Piping
Consider the scope on Major Non Intrusive Insp IF891B in the functional location GIR/FPSOT/COF/CHEM /IF891B, the given unit name of METHANOL SUBSEA FILTER (V), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/GAS/COMP /IPN-_HG-TO31-12-J21N, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be
Piping
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-27-F511, the given unit name of LINE GROUP,HP GAS,GAS,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Overhaul Inspection 5-PSV-19102 in the functional location DAL/FPSOH/GAS/FLARE/5-PSV-19102, the given unit name of PRES. SAFETY VALVE, ON HULL VENT HEADER, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on VII in the functional location PAZ/FPSOT/COF/FG /TO-V_-7001, the given unit name of HP FUEL GAS SCRUBBER, the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on MODTURBO COMP UA511Insp of 3rd structure in the functional location GIR/FPSOT/HSG/STRUC/MOD TURBO COMP UA511, the given unit name of STRUCTURAL MODULE TURBO COMP fr 72-78, the corresponding item class discipline would be
Structure
Consider the scope on PSV-Replace/Scrap in the functional location PAZ/FPSOT/COF/CHEM /TO-PSV-750545, the given unit name of PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on CLV/IPN-_HL-TO234 - External insp. + NDT in the functional location CLV/FPSOT/OIL/LOAD /IPN-_HL-TO25-12-B03, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be
Piping
Consider the scope on L1-Visual inspection of tertiary struc in the functional location PAZ/FPSOT/HSG/STRUC/L1, the given unit name of L1 Structural Module, the corresponding item class discipline would be
Structure
Consider the scope on External damage major inspection in the functional location PAZ/FPSOH/OIL/OWAT /IPN-_PW-HU27-02-D03, the given unit name of Produced water piping group, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location CLV/FPSOT/COF/FG /IPN-_FG-TO70-16-D23, the given unit name of Fuel gas piping group, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/OIL/SEP /IPN-NG-_420-13-B511, the given unit name of PIPING GROUP OIL SEPARATION, the corresponding item class discipline would be
Piping
Consider the scope on Replace/Scrap in the functional location CLV/FPSOH/OIL/OWAT /HU-PSV-27859B, the given unit name of SLOP WATER HEATER B PRESS. SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Replace/Scrap in the functional location PAZ/FPSOH/HSG/ACCOM/HU-PSV-820511A2, the given unit name of FAN UNIT PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Major Intrusive Insp DA603 in the functional location GIR/FPSOT/GAS/DEHYD/DA603, the given unit name of OVERHEAD DRUM (V), the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on BOATLANDING INSPECT. BALCONY BP STARBOAR in the functional location PAZ/FPSOH/HSG/STRUC/BOATLANDING STBD AFT, the given unit name of BOATLANDING PLATFORM STARBOARD AFT, the corresponding item class discipline would be
Structure
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/DEHYD/IPN-_DF-0655-03-F513, the given unit name of LINE GROUP,GAS DEHYD,DRAIN,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on BV tasks & intrusive major inspection in the functional location PAZ/FPSOH/OIL/STAB /HU-T_-2112A, the given unit name of DESALTING TANK 1P, the corresponding item class discipline would be
FU Items
Consider the scope on Non-Intrusive Inspection in the functional location PAZ/FPSOH/CRS/HVAC /HU-EL-0911C, the given unit name of MAIN CHW UNIT C CONDENSER COOLING C, the corresponding item class discipline would be
FU Items
Consider the scope on Major Non-Intrusive Inspection + UTC in the functional location CLV/FPSOT/ELE/PWG /TO-TZ-6019B, the given unit name of LUBE OIL RUNDOWN TANK FOR DE/NDE B, the corresponding item class discipline would be
Non Structural Tank
Consider the scope on Non-Intrusive Major Inspection in the functional location PAZ/FPSOT/COF/FG /TO-V_-7002, the given unit name of LP FUEL GAS SCRUBBER, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Overhaul Inspection 6-PSV-11506C in the functional location DAL/FPSOT/CRS/AIR /6-PSV-11506C, the given unit name of PRES. SAFETY VALVE, ON MOISTURE SEP., the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/OIL/OWAT /IPN-_PW-TO27-13-D03, the given unit name of Produced water piping group, the corresponding item class discipline would be
Piping
Consider the scope on Major Non intrusive inspection in the functional location PAZ/FPSOT/WAT/WDEOX/TO-VZ-5320C, the given unit name of SRU MEMBRANE HOUSING TRAIN 3, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on COR - APT_P_CP Measurement in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8631B, the given unit name of NO2 PORT WATER BALLAST TANK_WBT 2P, the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on Overhaul in the functional location CLV/FPSOT/GAS/COMP /TO-PSV-31318B1, the given unit name of HP1 COMP. B PRESS. SAFETY VALVE B1, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Overhaul in the functional location PAZ/FPSOT/GAS/COMP /TO-PSV2-31503, the given unit name of PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + External damage major inspection in the functional location GIR/FPSOT/EXT/EWELL/IPN-NH-_410-18-F511, the given unit name of PIPING GROUP EXTRACTION WELL, the corresponding item class discipline would be
Piping
Consider the scope on Non-Intrusive Major inspection in the functional location CLV/FPSOT/HSG/UPWAT/IPC-_BW-TO85-03-D49, the given unit name of Fresh water piping group, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/OIL/OWAT /IPN-_PW-TO27-06-D03, the given unit name of Produced water piping group, the corresponding item class discipline would be
Piping
Consider the scope on PSD Replacement in the functional location CLV/FPSOH/CRS/FWAT /HU-PSV-01951B, the given unit name of INSTR. AIR RESERVOIR PRESS. SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Overhaul in the functional location CLV/FPSOT/COF/CHEM /TO-PSV-75407A, the given unit name of TO-P_-7540A OUTLET PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on DAL/BUOY COMPARTMENT TURRET in the functional location DAL/BUOY /HSG/STRUC/TURRET, the given unit name of DALIA BUOY TURRET, the corresponding item class discipline would be
FU Items
Consider the scope on CLV/HUJE0202D- 12 Monthly Inspection in the functional location CLV/FPSOH/CRS/SAFE /HU-JE-0202D, the given unit name of FREE FALL LIFEBOAT DAVIT (NO4), the corresponding item class discipline would be
Lifting
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/OIL/TRANS/IPN-_HC-TO23-06-J03P, the given unit name of Hydrocarbon G/L piping group, the corresponding item class discipline would be
Piping
Consider the scope on Non intrusive major 2-DA-1007 in the functional location DAL/FPSOT/CRS/CONT /2-DA-1007, the given unit name of NITROGEN PRECHARGE ACCUMULATOR, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on CLV/BUOY COMPART_INTRUSIVE in the functional location CLV/BUOY /HSG/STRUC/COMP C9, the given unit name of BUOY COMPARTMENT, the corresponding item class discipline would be
FU Items
Consider the scope on 5-TA-6100/FU Tank Intermediate Survey in the functional location DAL/FPSOH/OIL/STORE/5-TA-6100, the given unit name of SLOP TANK PORT. CLEAN, the corresponding item class discipline would be
FU Items
Consider the scope on MOD.COMPUB512 Insp of tertiary structuct in the functional location GIR/FPSOT/HSG/STRUC/MOD GAS COMP UB512, the given unit name of STRUCTURAL MODULE GAS COMP fr 71-78, the corresponding item class discipline would be
Structure
Consider the scope on Major Non Intrusive Insp 6-DA-5202B in the functional location DAL/FPSOT/GAS/COMP /6-DA-5202B, the given unit name of OIL ACCUMULATOR, MINERAL OIL CIRCULATION, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/WAT/WINJ /IPN-DS-_454-19-B630, the given unit name of PIPING GROUP WATER INJECTION, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/WAT/WDEOX/IPN-_SW-TO53-11-H49, the given unit name of Sea water piping group, the corresponding item class discipline would be
Piping
Consider the scope on Overhaul in the functional location CLV/FPSOT/GAS/DEHYD/TO-PSV-30102B1, the given unit name of INLET SCRUBBER B PRESS. SAFETY VALVE B1, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Overhaul in the functional location PAZ/FPSOT/GAS/COMP /TO-PSV-31535, the given unit name of GAS INLET PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on COR - WBT1P - CP Measurement in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8110, the given unit name of NO.1 WATER BALLAST TANK (P), the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on Scrap/replace in the functional location GIR/FPSOT/WAT/WINJ /41-PSV7503M, the given unit name of IF703M SOUPAPE DE SECURITE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on GIR/ FU CHAIN LOCKER EMER Class Survey in the functional location GIR/FPSOH/HSG/STRUC/CHAIN-LOCKER-EMER, the given unit name of CHAIN LOCKER EMERGENCY, the corresponding item class discipline would be
FU Items
Consider the scope on Intrusive major inspection in the functional location GIR/FPSOH/OIL/DRAIN/BILGE WELL AFT PORT, the given unit name of BILGE WELL MACHINERY SPACE TANK TOP, the corresponding item class discipline would be
FU Items
Consider the scope on PAZ Gas Cylinders & Accumulators Campaig in the functional location PAZ/FPSOT/CRS/SAFE /GC-ACC, the given unit name of PAZ-GAS CYLINDERS & ACCUMULATORS, the corresponding item class discipline would be
Campaign
Consider the scope on Major Non Intrusive Insp TA942 in the functional location GIR/FPSOH/COF/COOLW/TA942, the given unit name of AUX COOLING FRESH WATER TANK (T), the corresponding item class discipline would be
FU Items
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/GAS/COMP /TO-PSV-3131_2A, the given unit name of VSD COOLING WATER PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Non-Intrusive Inspection in the functional location PAZ/FPSOH/HSG/UPWAT/HU-EP-8521B, the given unit name of CHILLED WATER HEAT EXCHANGER, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on VII in the functional location PAZ/FPSOT/COF/FG /TO-ES-7002, the given unit name of FUEL GAS START-UP COOLER, the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on PSD Replacement in the functional location CLV/FPSOH/HSG/ACCOM/HU-PSV-41001A, the given unit name of CONDENSER UNIT A PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + External damage major inspection in the functional location GIR/FPSOT/OIL/OWAT /IPN-NW-_427-03-B511, the given unit name of PIPING GROUP OILY WATER, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/WAT/WATLF/IPN-_SW-TO50-14-B90, the given unit name of Sea water piping group, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/FLARE/IPN-_FS-0621-11-B513, the given unit name of LINE GROUP,FLARE,FLARES,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Non-Intrusive Major inspection in the functional location GIR/FPSOT/COF/COOLW/IPN-CW-_476-05-B561, the given unit name of PIPING GROUP COOLING WATER, the corresponding item class discipline would be
Piping
Consider the scope on Major Non Intrusive Insp 6-DA-4120A in the functional location DAL/FPSOT/COF/INWAT/6-DA-4120A, the given unit name of REJECT SURGE DRUM, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Overhaul in the functional location CLV/FPSOT/OIL/SEP /TO-PSV-20116B, the given unit name of TUBE RUPTURE PRESS. SAF. VLV B, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on DAL/6-TSV-63500B-Replace/Scrap in the functional location DAL/FPSOT/OIL/METER/6-TSV-63500B, the given unit name of THERMAL SAFETY VALVE, ON METER RUN LINE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Insp-GIR-FPSOH/MOORING TENSIONER FWD SB in the functional location GIR/FPSOH/HSG/STRUC/FPSO-MT-FWD-PLAT SB, the given unit name of MOORING TENSIONER PLATEFORM FWD SB, the corresponding item class discipline would be
FU Items
Consider the scope on COR - WB3S - CP Measurement in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8612C, the given unit name of STARBOARD WING BALLAST 3S, the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on Major Non Intrusive Insp IF902F in the functional location GIR/FPSOT/COF/COOLW/IF902F, the given unit name of SEAWATER FILTER COOLING NETWORK (V), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/OIL/SEP /IPC-_GH-0632-12-C513, the given unit name of LINE GROUP,OIL HEAT,OILY EFLUENT,CS,IPC, the corresponding item class discipline would be
Piping
Consider the scope on GIR/41-TSV-1011-Replace/Scrap in the functional location GIR/FPSOT/EXT/EWELL/41-TSV1011, the given unit name of SOUPAPE THERMIQUE SECURITE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on FPSO-DECK/FU GVI in the functional location GIR/FPSOH/HSG/STRUC/DECK, the given unit name of GIRASSOL FPSO-DECK, the corresponding item class discipline would be
FU Items
Consider the scope on P1-B_Visual inspection of complet struct in the functional location GIR/FPSOT/HSG/STRUC/MOD P1-B, the given unit name of STRUCTURAL MODULE P1-B Fr 48-52, the corresponding item class discipline would be
Structure
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/CRS/AIR /TO-PSV-079163, the given unit name of HPU ACCUMULATOR PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/CRS/FWAT /TO-PSV-01532, the given unit name of AIR RESERVOIR OUTLET PRESS SAFE VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0631-02-B513, the given unit name of LINE GROUP,OIL 1ST,GAS,CS,IPN, the corresponding item class discipline would be
Piping