instruction
stringlengths
150
245
output
stringclasses
28 values
Consider the scope on Major Non Intrusive Insp 6-DASBDV-12001C in the functional location DAL/FPSOT/ELE/PWG /6-DASBDV-12001C, the given unit name of AIR CAPACITY, FUEL GAS SCRUBBER, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on HELIPAD TEPA GVI in the functional location CLV/FPSOH/HSG/STRUC/HELID-DECK-PRM_STR, the given unit name of Primary structure of HELIDECK module, the corresponding item class discipline would be
Structure
Consider the scope on UTC + External Major Inspection in the functional location DAL/FPSOT/COF/INWAT/IPN-_NW-0641-08-B513, the given unit name of LINE GROUP,H2O TREAT,WATER,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/GAS/DEHYD/TO-PSV-30252B2, the given unit name of TEG CIRC. PUMP 2 OUTLET PRESS SAFE VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Non-Intrusive Major Inspection in the functional location PAZ/FPSOH/CRS/FWAT /HU-VB-0101A3, the given unit name of AIR START GAS VESSEL A3, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on DAL/BUOY COMPART_INTRUSIVE in the functional location DAL/BUOY /HSG/STRUC/COMP 13, the given unit name of BUOY TANK COMPARTMENT, the corresponding item class discipline would be
FU Items
Consider the scope on Non intrusive inspection 5-EC-1230B in the functional location DAL/FPSOH/ELE/PWG /5-EC-1230B, the given unit name of ESSENTIAL HEAT EXCHANGER, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on 5-TA-8155/FU Tank GVI in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8155, the given unit name of NO.5 WATER BALLAST TANK (S), the corresponding item class discipline would be
FU Items
Consider the scope on COR - WB1S - CP Measurement in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8612A, the given unit name of STARBOARD WING BALLAST 1S, the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on UTC + External Major Inspection in the functional location DAL/FPSOT/COF/INWAT/IPN-_NW-0641-10-B513, the given unit name of LINE GROUP,H2O TREAT,WATER,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/GAS/FLARE/IPN-NG-_436-34-D661, the given unit name of PIPING GROUP GAS FLARE, the corresponding item class discipline would be
Piping
Consider the scope on CLV/BUOY/OB-JZ-8660B_Tanker Side in the functional location CLV/BUOY /HSG/STRUC/OB-JZ-8660B, the given unit name of BUOY MOORING HAWSER ASSEMBLY, the corresponding item class discipline would be
FU Items
Consider the scope on First Topside P52 Structure Inspection in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P52-PRM-STR, the given unit name of MODULE P52,TOPSIDE PRIMARY STRUCTURE, the corresponding item class discipline would be
Structure
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/GAS/COMP /TO-PSV-31861A, the given unit name of TO HP FLARE PRESS. SAFETY VALVE A, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Air Cylinder Campaign in the functional location PAZ/FPSOT/ELE/PWG /TO-VA-7201E, the given unit name of DAMPER SEALING AIR RESERVOIR, the corresponding item class discipline would be
Campaign
Consider the scope on Insp Group Line IPN-_NG-0654-07-D670 in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0654-07-D670, the given unit name of LINE GROUP,GAS COMP,GAS,SS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Non Intrusive Major Inspection_MNT in the functional location CLV/FPSOT/WAT/WATLF/TO-VF-5011C, the given unit name of FILTER NO2, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Overhaul Inspection 6-PSV1-41502B1 in the functional location DAL/FPSOT/COF/INWAT/6-PSV1-41502B1, the given unit name of PRES. SAFETY VALVE, ON HYDROCYCLONE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Major Non Intrusive Insp TA911B in the functional location GIR/FPSOH/HSG/UPWAT/TA911B, the given unit name of PERMEATE TANK (T), the corresponding item class discipline would be
Non Structural Tank
Consider the scope on Non-Intrusive Major inspection in the functional location CLV/FPSOT/OIL/DRAIN/IPN-_CD-TO28-20-D49, the given unit name of Closed drain piping group, the corresponding item class discipline would be
Piping
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/OIL/TRANS/IPN-_HC-TO23-05-J03, the given unit name of Hydrocarbon G/L piping group, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0656-04-F513, the given unit name of LINE GROUP,GAS LIFT,GAS,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Overhaul Inspection 6-PSV3-34004A in the functional location DAL/FPSOT/OIL/SEP /6-PSV3-34004A, the given unit name of PRES. SAF. VALVE, ON 2ND STAGE SEPARATOR, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on RB_PS-visual inspection of tertiary stru in the functional location PAZ/FPSOH/HSG/STRUC/RISER BALCONY PS, the given unit name of RISER BALCONY PORTSIDE, the corresponding item class discipline would be
Structure
Consider the scope on Overhaul in the functional location CLV/FPSOT/ELE/PWG /TO-PSV-60158C, the given unit name of TO HP FLARE PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Visual inspection of tertiary structure in the functional location PAZ/FPSOT/HSG/STRUC/R8, the given unit name of R8 Structural Module, the corresponding item class discipline would be
Structure
Consider the scope on Intrusive major 2-DA-1001 in the functional location DAL/FPSOT/CRS/CONT /2-DA-1001, the given unit name of NITROGEN PRECHARGE ACCUMULATOR, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on HU-TR-8632F1 FU/TEPA GVI Intermed. insp. in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8632F1, the given unit name of NO6 STBD AFT WATER BALLAST TANK_WBT 6SA, the corresponding item class discipline would be
FU Items
Consider the scope on CLV/IPN-_HL-TO241 - External insp. + NDT in the functional location CLV/FPSOT/OIL/LOAD /IPN-_HL-TO25-19-B03, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be
Piping
Consider the scope on Non-Intrusive Inspection in the functional location PAZ/FPSOH/CRS/HVAC /HU-EW-0911C, the given unit name of MAIN CHILLED WATER UNIT C EVAPORATOR C, the corresponding item class discipline would be
FU Items
Consider the scope on COR - WBT1P - CP Measurement in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8110, the given unit name of NO.1 WATER BALLAST TANK (P), the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/GAS/DEHYD/TO-PSV-30252B1, the given unit name of TEG CIRC. PUMP 1 OUTLET PRESS SAFE VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOH/OIL/SDS /IPN-_HL-HU29-01-B03, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be
Piping
Consider the scope on Insp Group Line IPN-_FS-0621-06-B663 in the functional location DAL/FPSOT/GAS/FLARE/IPN-_FS-0621-06-B663, the given unit name of LINE GROUP,FLARE,FLARES,LTCS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Non-Intrusive Inspection in the functional location PAZ/FPSOH/CRS/HVAC /HU-EW-0911B, the given unit name of MAIN CHILLED WATER UNIT B EVAPORATOR B, the corresponding item class discipline would be
Non Structural Tank
Consider the scope on Major Non Intrusive Insp EC517B1 in the functional location GIR/FPSOT/GAS/COMP /EC517B1-EXCH, the given unit name of YD511B-EXCHANGER WATER/OIL (E), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Non intrusive inspection 5-EC-1230A in the functional location DAL/FPSOH/ELE/PWG /5-EC-1230A, the given unit name of ESSENTIAL HEAT EXCHANGER, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on CLV/TO-VP-1030-Non Intrusive Maj. Insp. in the functional location CLV/FPSOT/EXT/EWELL/TO-VP-1030, the given unit name of O11W & OV CENTRAL LOOP LEFT BR. PIG TRAP, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Replace/Scrap 5-PSV-96002 in the functional location DAL/FPSOH/CRS/HVAC /5-PSV-96002, the given unit name of PRESSURE SAFETY VALVE, EXPANSION TANK, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on PSD Replacement in the functional location CLV/FPSOH/CRS/HVAC /HU-PSV-093705, the given unit name of FWD ACU B1 PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on VII in the functional location DAL/FPSOT/OIL/STAB /6-IF-7801, the given unit name of CARTRIDGE FILTER FOR CIP WWP, the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on Major Intrusive Insp DA7543A in the functional location GIR/FPSOT/WAT/WINJ /DA754-3A, the given unit name of UB754-5A FUEL GAS SCRUBBER (V), the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-20-D710, the given unit name of LINE GROUP,HP GAS,GAS,DUPLEX,IPN, the corresponding item class discipline would be
Piping
Consider the scope on MACH SPACE LEVEL5/GVI in the functional location PAZ/FPSOH/HSG/STRUC/ MACH SPACE-LEVEL-5, the given unit name of Machinery space level -5, the corresponding item class discipline would be
FU Items
Consider the scope on CLV/TOEP31312A70-Sample Ext. Insp + UT in the functional location CLV/FPSOT/GAS/COMP /TO-EP-3131_2A-070, the given unit name of VSD COOLING WATER EXCHANGER, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Scrap/Replace in the functional location CLV/FPSOT/COF/CHEM /TO-PSV-75571A2, the given unit name of DEMULS. PUMP A2 OUTLET PRESS SAFE. VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + External damage major inspection in the functional location GIR/FPSOT/COF/FG /IPC-FG-_470-08-C511, the given unit name of PIPING GROUP FUEL GAS, the corresponding item class discipline would be
Piping
Consider the scope on Major Non Intru Insp 6-DANROV2-P61451 in the functional location DAL/FPSOT/CRS/FWAT /6-DANROV2-P61451, the given unit name of AIR CAPACITY FLOOD/CARGO DECK 1-P, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/CRS/AIR /TO-PSV-079157, the given unit name of HPU ACCUMULATOR PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on SCD + External damage major inspection in the functional location PAZ/FPSOT/GAS/DEHYD/IPN-_HL-TO30-01-G49, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be
Piping
Consider the scope on Insp Group Line IPN-_GH-0634-02-B513 in the functional location DAL/FPSOT/OIL/SEP /IPN-_GH-0634-02-B513, the given unit name of LINE GROUP,OIL 2ND,OILY EFLUENT,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on CLV/IPN-_CD-TO352 - External insp. + NDT in the functional location CLV/FPSOT/OIL/DRAIN/IPN-_CD-TO28-29-J01, the given unit name of Closed drain piping group, the corresponding item class discipline would be
Piping
Consider the scope on VII in the functional location CLV/FPSOT/COF/INERT/TO-VZ-7421, the given unit name of DECK WATER SEAL, the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on CLV/ WEIGHT SCALE inspection VIE in the functional location CLV/FPSOT, the given unit name of CLOV - TOPSIDES, the corresponding item class discipline would be
Campaign
Consider the scope on Insp Group Line IPN-_NG-0651-05-B513 in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0651-05-B513, the given unit name of LINE GROUP,LP GAS,GAS,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on Complet. Topside P13 Structure Insp. in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P13, the given unit name of P13 Structural Module, the corresponding item class discipline would be
Structure
Consider the scope on Insp Group Line IPN-_DF-0637-11-F513 in the functional location DAL/FPSOT/GAS/COMP /IPN-_DF-0637-11-F513, the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on External Inspection in the functional location DAL/FPSOH/HSG/UPWAT/5-DA-9310, the given unit name of DOMESTIC FRESH WATER HYDROPHORE TANK, the corresponding item class discipline would be
FU Items
Consider the scope on GIR/41-TSV-90202C-Replace/Scrap in the functional location GIR/FPSOT/COF/COOLW/41-TSV90202C, the given unit name of EC941C SOUPAPE THERM. SECURITE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on TA054/COR CP Measurement in the functional location GIR/FPSOH/HSG/STRUC/TA054, the given unit name of WATER BALLAST 1 STARBOARD (T), the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on MOD.E&I BLD.Visual insp of complet struc in the functional location GIR/FPSOT/HSG/STRUC/MOD E_I BUILDING, the given unit name of STRUCTURAL MODULE E&I BUILDING fr 50-56, the corresponding item class discipline would be
Structure
Consider the scope on Overhaul in the functional location CLV/FPSOT/EXT/EWELL/TO-PSV-10212, the given unit name of PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on VII in the functional location PAZ/FPSOT/COF/COOLW/TO-V_-7602, the given unit name of TOPSIDES CW EXPANSION DRUM, the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on External damage major inspection in the functional location PAZ/FPSOH/CRS/HVAC /IPC-_CH-HU09-01-_01, the given unit name of Chilled water piping group, the corresponding item class discipline would be
Piping
Consider the scope on 5-TA-8100/FU Tank Class Survey in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8100, the given unit name of FORE PEAK TANK (P), the corresponding item class discipline would be
FU Items
Consider the scope on 41-TSV-8505 INSPECTION in the functional location GIR/FPSOT/COF/CHEM /41-TSV-8505, the given unit name of SOUPAPE DE SECURITE RETOUR METHANOL TA89, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Insp Group Line IPN-_DF-0637-77-F513 in the functional location DAL/FPSOT/OIL/DRAIN/IPN-_DF-0637-77-F513, the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on DAL/6-TSV-19009-Replace/Scrap in the functional location DAL/FPSOT/COF/CHEM /6-TSV-19009, the given unit name of THERMAL SAFETY VALVE, METHANOL RETURN, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 06 MONTHLY INSPECTION CAMPAIGN in the functional location PAZ/FPSOH/COF/LIFT, the given unit name of Lifting equipment, the corresponding item class discipline would be
Campaign
Consider the scope on Overhaul in the functional location CLV/FPSOT/WAT/WDEOX/TO-PSV-53253, the given unit name of DEOX. VESSEL OUTLET PRESS. SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Major Non Intrusive Insp DA973 in the functional location GIR/FPSOT/COF/INERT/DA973, the given unit name of KX973 NITROGEN DRUM (V), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Remote Int. Inspection-TO-FL-3620 in the functional location PAZ/FPSOT/GAS/FLARE/TO-FL-3620, the given unit name of LP FLARE TIP, the corresponding item class discipline would be
Flare TIP
Consider the scope on Major Non Intrusive Insp 6-DASBDV-31210 in the functional location DAL/FPSOT/EXT/TRANS/6-DASBDV-31210, the given unit name of AIR CAPACITY, ON PROD. HEADER, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/COF/CHEM /IPN-_XX-0636-12-G580, the given unit name of LINE GROUP,CHEM INJECT°,CHEMICAL,SS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on COR - WBT2P - CP Measurement in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8120, the given unit name of NO.2 WATER BALLAST TANK (P), the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on COR - APT_P_CP Measurement in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8621, the given unit name of AFT PORT BALLAST WATER TANK_WBT AP, the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on Overhaul in the functional location CLV/FPSOT/GAS/COMP /TO-PSV-31418B2, the given unit name of HP2 COMP. B PRESS. SAFETY VALVE B2, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on CLV-CRANES/L3/TO-JA-7830A/ME-EL/1Y in the functional location CLV/FPSOT/COF/LIFT /TO-JA-7830A, the given unit name of PEDESTAL CRANE, the corresponding item class discipline would be
Lifting
Consider the scope on Major Non-Intrusive Inspection + UTC in the functional location CLV/FPSOT/ELE/PWG /TO-TZ-6019C, the given unit name of LUBE OIL RUNDOWN TANK FOR DE/NDE C, the corresponding item class discipline would be
Non Structural Tank
Consider the scope on MACH SPACE STRINGER DECK/FU GVI in the functional location GIR/FPSOH/HSG/STRUC/MACH-STRINGER DECK, the given unit name of GIRASSOL MACH SPACES STRINGER DECK, the corresponding item class discipline would be
FU Items
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/EXT/EWELL/IPN-_NH-0630-58-F513, the given unit name of LINE GROUP,OIL RAW,OIL,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on VDP0019/FU Cofferdam Class Survey in the functional location DAL/FPSOH/HSG/STRUC/5-VOID-P-FR-00_19, the given unit name of VOID PORTSIDE FRAME 0-19, the corresponding item class discipline would be
FU Items
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/GAS/COMP /IPN-GT-_431-20-E513S, the given unit name of PIPING GROUP GAS COMPRESSION, the corresponding item class discipline would be
Piping
Consider the scope on VII in the functional location CLV/FPSOT/OIL/OWAT /TO-UF-2720A, the given unit name of PRODUCED WATER CYCLONIC DESANDER A, the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on PSV-Replace/Scrap in the functional location PAZ/FPSOT/COF/CHEM /TO-PSV-750540, the given unit name of BIOCIDE 3 PUMP PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Non-Intrusive Major inspection in the functional location CLV/FPSOT/OIL/DRAIN/IPN-_CD-TO28-08-B03, the given unit name of Closed drain piping group, the corresponding item class discipline would be
Piping
Consider the scope on Non-Intrusive Intermediate Inspection in the functional location PAZ/FPSOH/COF/FO /HU-TZ-7151C, the given unit name of 4 REEL STATION HYDRAULIC TANK, the corresponding item class discipline would be
Non Structural Tank
Consider the scope on GIR/41-PSV-8461A-Replace/Scrap in the functional location GIR/FPSOT/COF/CHEM /41-PSV8461A, the given unit name of GX845A SOUPAPE DE SECURITE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on GIR/41-PSV1-3115-Révision in the functional location GIR/FPSOT/OIL/SEP /41-PSV1-3115, the given unit name of DS304 SOUPAPE DE SECURITE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/OIL/LOAD /IPN-_HL-TO25-02-D03, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be
Piping
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/GAS/COMP /TO-TSV-31860A, the given unit name of GAS HEATER A OUTLET THERM. SAFE. VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Insp Group Line IPN-_NC-0652-12-D670 in the functional location DAL/FPSOT/GAS/COMP /IPN-_NC-0652-12-D670, the given unit name of LINE GROUP,HP GAS,RAW COND,SS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on CLV/IPN-_HH-HU058 - External insp. + NDT in the functional location CLV/FPSOH/CRS/AIR /IPN-_HH-HU07-01-_49, the given unit name of Hydraulic fluid piping group, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/OIL/SEP /IPN-_GH-0631-19-B513, the given unit name of LINE GROUP,OIL 1ST,OILY EFLUENT,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/WAT/WINJ /IPN-XX-_454-09-B630, the given unit name of PIPING GROUP WATER INJECTION, the corresponding item class discipline would be
Piping
Consider the scope on Major Non Intrusive Insp IF703C in the functional location GIR/FPSOT/WAT/WINJ /IF703C, the given unit name of MULTIMEDIA FILTER (V), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on UTC + External damage major inspection in the functional location GIR/FPSOT/EXT/EWELL/IPN-NH-_410-16-F511, the given unit name of PIPING GROUP EXTRACTION WELL, the corresponding item class discipline would be
Piping
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/COF/CHEM /IPN-XX-_475-22-B580, the given unit name of PIPING GROUP CHEMICAL INJECTION, the corresponding item class discipline would be
Piping
Consider the scope on Non Intrusive Major Inspection_MNT in the functional location CLV/FPSOH/COF/LIFT /HU-TZ-7811A, the given unit name of PORT RPS HPU DIESEL TANK, the corresponding item class discipline would be
Non Structural Tank
Consider the scope on Major Intrusive Inspection 6-EC-5700 in the functional location DAL/FPSOT/GAS/COMP /6-EC-5700, the given unit name of GAS EXPORT DEPRESSURISATION HEATER, the corresponding item class discipline would be
Pressure Vessel (VII)