instruction stringlengths 150 245 | output stringclasses 28 values |
|---|---|
Consider the scope on Overhaul Inspection 6-PSV1-51116 in the functional location DAL/FPSOT/GAS/COMP /6-PSV1-51116, the given unit name of PRES. SAF. VALVE, ON SUCTION SCRUBBER, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on SCD + External damage major inspection in the functional location PAZ/FPSOT/COF/CHEM /IPN-_XX-TO75-01-_50, the given unit name of Special chemical piping group, the corresponding item class discipline would be | Piping |
Consider the scope on UTC + External damage major inspection in the functional location CLV/FPSOT/OIL/SEP /IPN-_HL-TO20-04-B03, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on DAL/6-PSV-52531A-Replace/Scrap in the functional location DAL/FPSOT/GAS/COMP /6-PSV-52531A, the given unit name of PRES. SAFETY VALVE, ON FUEL GAS SCRUBBER, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on CLV/TOEP3131_2B-70-Sample Ext. Insp + UT in the functional location CLV/FPSOT/GAS/COMP /TO-EP-3131_2B-070, the given unit name of VSD COOLING WATER EXCHANGER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Complet. Topside P33 Structure Insp. in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P33, the given unit name of P33 Structural Module, the corresponding item class discipline would be | Structure |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/GAS/TRANS/IPN-_HG-TO34-16-H49, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/OIL/LOAD /IPN-_NH-0683-07-C513, the given unit name of LINE GROUP,OFFLOAD,OIL,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on Class-Overhaul Inspection 5-PSV-61009 in the functional location DAL/FPSOH/GAS/FLARE/5-PSV-61009, the given unit name of CLASS PSV, ON HULL VENT HEADER, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Overhaul in the functional location PAZ/FPSOT/GAS/COMP /TO-PSV2-31213, the given unit name of SUCTION SCRUBBER PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Major Intrusive Inspection 6-DA-4120B in the functional location DAL/FPSOT/COF/INWAT/6-DA-4120B, the given unit name of REJECT SURGE DRUM, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOH/GAS/FLARE/IPN-_VE-LQ36-02-_91, the given unit name of Vent piping group, the corresponding item class discipline would be | Piping |
Consider the scope on CLOV VISUAL INSPECTION BOATLANDING PSIDE in the functional location CLV/FPSOH/HSG/STRUC/BOATLANDING PORT AFT, the given unit name of Boat Landig Portside AFT, the corresponding item class discipline would be | FU Items |
Consider the scope on SCD + External damage major inspection in the functional location PAZ/FPSOT/GAS/COMP /IPC-_HG-TO31-17-D70, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on COR - APT_P_CP Measurement in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8629, the given unit name of PORT MAIN BUFFER TANK_BF P, the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on TA047/COR CP Measurement in the functional location GIR/FPSOH/HSG/STRUC/TA047, the given unit name of WATER BALLAST 4 PORTSIDE (T), the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on MACH SPACE LEVEL3/GVI in the functional location PAZ/FPSOH/HSG/STRUC/ MACH SPACE-LEVEL 3, the given unit name of Machinery space level -3, the corresponding item class discipline would be | FU Items |
Consider the scope on Non-Intrusive Major Inspection in the functional location PAZ/FPSOT/OIL/SEP /TO-VP-2025B, the given unit name of UM GAS LOOP P30 FLN 2 PIG TRAP B, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Major Non Intrusive Insp + UTC in the functional location PAZ/FPSOH/COF/COOLW/HU-V_-7606C, the given unit name of ESDGC C.W EXPANSION DRUM, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/OIL/METER/TO-TSV-26153C, the given unit name of FISCAL METERING PACK. TEMP. SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on CLV/INSP-BUOY QUICK RELEASE HOOK B in the functional location CLV/BUOY /HSG/STRUC/OB-JL-8660B, the given unit name of BUOY QUICK RELEASE HOOK B, the corresponding item class discipline would be | FU Items |
Consider the scope on PSD Replacement in the functional location CLV/FPSOH/CRS/FWAT /HU-PSV-01951B-DBL, the given unit name of FOAM STORAGE TANK B PRESS. SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Major Non-Intrusive Inspection in the functional location PAZ/FPSOT/COF/FG /TO-HE-7001B, the given unit name of HP FUEL GAS HEATER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Visual inspection of tertiary structure in the functional location PAZ/FPSOT/HSG/STRUC/P3, the given unit name of P3 Structural Module, the corresponding item class discipline would be | Structure |
Consider the scope on Major Non Intrusive Insp + UTC in the functional location PAZ/FPSOH/CRS/FWAT /HU-TA-0102A, the given unit name of FW SYSTEM JOCKEY PUMP A HEADER TANK, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on Overhaul in the functional location CLV/FPSOT/GAS/DEHYD/TO-PSV-30245B, the given unit name of CARBON FILTER INLET PRESS. SAFE. VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/OIL/TRANS/IPN-_HC-TO23-02-J70, the given unit name of Hydrocarbon G/L piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Non Intrusive Major Inspection in the functional location GIR/FPSOT/CRS/AIR /DS831A, the given unit name of KX830A-AIR/ WATER SEPARATOR (V), the corresponding item class discipline would be | Lifting |
Consider the scope on Second Topside P32 Structure Inspection in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P32-PRM-STR, the given unit name of MODULE P32,TOPSIDE PRIMARY STRUCTURE, the corresponding item class discipline would be | Structure |
Consider the scope on Overhaul in the functional location PAZ/FPSOT/OIL/METER/TO-PSV-26015, the given unit name of CRUDE OIL METERING PRESS.SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/OIL/STAB /IPN-_GH-0633-03-C513, the given unit name of LINE GROUP,OIL DESAL,OILY EFLUENT,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/OIL/STAB /IPC-_NW-0633-05-B513, the given unit name of LINE GROUP,OIL DESALT,WATER,CS,IPC, the corresponding item class discipline would be | Piping |
Consider the scope on GIR/41-PSV-7296B--Replace/Scrap in the functional location GIR/FPSOT/WAT/WINJ /41-PSV7296B, the given unit name of GX703B SOUPAPE DE SECURITE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/OIL/OWAT /IPN-_HL-TO27-01-B03, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Major Non Intrusive Insp 6-IF-6301D in the functional location DAL/FPSOT/OIL/METER/6-IF-6301D, the given unit name of FILTER, ON METER RUN LINE, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on PSV-Scrap/Replace in the functional location PAZ/FPSOH/CRS/AIR /HU-PSV-07104B, the given unit name of PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Major Non Intrusive Insp IF703H in the functional location GIR/FPSOT/WAT/WINJ /IF703H, the given unit name of MULTIMEDIA FILTER (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Overhaul in the functional location CLV/FPSOT/WAT/WINJ /TO-PSV-54206A2, the given unit name of TO-P_-5420A OUTLET PRESS SAFETY VALVE A2, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on MACH SPACE TANK TOP/GVI in the functional location PAZ/FPSOH/HSG/STRUC/ MACH SPACE-TANK TOP, the given unit name of Machinery space Tank top, the corresponding item class discipline would be | FU Items |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/OIL/SEP /IPN-_PW-TO20-02-D03, the given unit name of Produced water piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Inspection-TELECOM STRUCTURE in the functional location DAL/FPSOA/CRS/TELE, the given unit name of COMMUNICATION/TELECOM, the corresponding item class discipline would be | Structure |
Consider the scope on Major Non Intrusive Insp 6-DS-5210A in the functional location DAL/FPSOT/GAS/COMP /6-DS-5210A, the given unit name of SUCTION SCRUBBER, 1ST STAGE HP COMPRES., the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Non Intrusive Major Inspection in the functional location GIR/FPSOT/COF/INERT/IF97101A, the given unit name of NITROGEN FILTER (V), the corresponding item class discipline would be | Lifting |
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-05-D511, the given unit name of LINE GROUP,HP GAS,GAS,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on CLV/IPN-_HL-TO245 - External insp. + NDT in the functional location CLV/FPSOT/GAS/FLARE/IPN-_HL-TO36-23-D49, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on PAZ - Buoy Hull GVI in the functional location PAZ/BUOY /HSG/STRUC/HULL, the given unit name of HULL FOR OFFLOADING BUOY, the corresponding item class discipline would be | FU Items |
Consider the scope on Intrusive Major Inspection in the functional location PAZ/FPSOT/GAS/COMP /TO-V_-3160, the given unit name of HHP COMPRESSOR SUCTION SCRUBBER, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on External Major Inspection in the functional location PAZ/FPSOT/COF/FG /IPN-_FG-TO70-02-D01, the given unit name of Fuel gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on TO-PSV-315130-Replace/SCrap in the functional location PAZ/FPSOT/GAS/COMP /TO-PSV-315130, the given unit name of OUTLET HEATER PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on DAL/6-TSV-21101-Replace/Scrap in the functional location DAL/FPSOT/COF/CHEM /6-TSV-21101, the given unit name of THERMAL SAFETY VALVE, METHANOL - LOOP301, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Overhaul in the functional location PAZ/FPSOH/CRS/AIR /HU-PSV-07101A, the given unit name of 1ST STAGE OUTLET PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/OIL/SEP /TO-PSV-20251B1, the given unit name of TO-VB-2020B1A OUTLET PRESS SAFE VALVE B1, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on VII in the functional location GIR/FPSOT/GAS/COMP /EC513B, the given unit name of 5TH STAGE GAS CONDENSER TRAIN B (V), the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on Insp Group Line IPN-_NC-0634-01-B670 in the functional location DAL/FPSOT/OIL/SEP /IPN-_NC-0634-01-B670, the given unit name of LINE GROUP,OIL 2ND,RAW COND,SS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on Insp Group Line IPN-_FS-0621-42-B513 in the functional location DAL/FPSOT/GAS/FLARE/IPN-_FS-0621-42-B513, the given unit name of LINE GROUP,FLARE,FLARES,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/OIL/OWAT /IPN-_PW-TO27-18-B03, the given unit name of Produced water piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Non-Intrusive Intermediate Inspection in the functional location PAZ/FPSOT/OIL/STAB /TO-ES-2112B2, the given unit name of WATER-CRUDE HEATER B2, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Scrap/replace in the functional location PAZ/FPSOT/CRS/FWAT /TO-PSV-011201A, the given unit name of DOUBLE DELUGE/AFFF PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on SCD + External damage major inspection in the functional location GIR/FPSOT/EXT/EWELL/IPN-NH-_410-03-F720, the given unit name of PIPING GROUP EXTRACTION WELL, the corresponding item class discipline would be | Piping |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/GAS/FLARE/IPN-_FS-0621-20-B513, the given unit name of LINE GROUP,FLARE,FLARES,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on GIR/41-PSV-2072B-Révision in the functional location GIR/FPSOT/GAS/FLARE/41-PSV2072B, the given unit name of SOUPAPE DE SECURITE GAZ INERTE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on GIR/41-PSV-8451A-Replace/Scrap in the functional location GIR/FPSOT/COF/CHEM /41-PSV8451A, the given unit name of GX844A SOUPAPE DE SECURITE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on External damage major inspection in the functional location GIR/FPSOT/GAS/DEHYD/IPN-NW-_430-21-B670, the given unit name of PIPING GROUP GAS DEHYDRATION, the corresponding item class discipline would be | Piping |
Consider the scope on Replacement/Scrap in the functional location CLV/FPSOT/CRS/FWAT /TO-PSE-01368, the given unit name of INERGEN MANIFOLD RUPTURE DISC, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Visual inspection of tertiary struc in the functional location CLV/FPSOT/HSG/STRUC/M125, the given unit name of M125 STR Module LP1 & LP2 GAS COMP, the corresponding item class discipline would be | Structure |
Consider the scope on CLV/TO-TZ7502-Non Intrusive Interm. Insp in the functional location CLV/FPSOT/COF/CHEM /TO-TZ-7502, the given unit name of PROCESS ANTI-FOAM STORAGE TANK, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on P1-A_Visual inspection of tertiary struc in the functional location GIR/FPSOT/HSG/STRUC/MOD P1-A, the given unit name of STRUCTURAL MODULE P1-A Fr 52-56, the corresponding item class discipline would be | Structure |
Consider the scope on SCD + External damage major inspection in the functional location PAZ/FPSOT/COF/CHEM /IPN-_XX-TO75-03-_50, the given unit name of Special chemical piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Non-Intrusive Major inspection in the functional location CLV/FPSOH/OIL/STAB /IPN-_HG-HU21-32-B03, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Inspection - GIR - HELIDECK in the functional location GIR/FPSOT/HSG/STRUC/HELIDECK, the given unit name of HELIDECK DU FPSO GIRASSOL, the corresponding item class discipline would be | FU Items |
Consider the scope on PSV-Scrap/Replace in the functional location PAZ/FPSOT/WAT/WINJ /TO-TSV-54051B, the given unit name of WATER DISTRIB THERMAL SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on EXCHANGERS Visual insp of complet struct in the functional location GIR/FPSOT/HSG/STRUC/MOD EXCHANGERS, the given unit name of STRUCTURAL MODULE ECHANGERS fr 56-58, the corresponding item class discipline would be | Structure |
Consider the scope on BUOY HULL - Inspection Topside in the functional location DAL/BUOY /HSG/STRUC/HULL, the given unit name of DALIA BUOY HULL, the corresponding item class discipline would be | FU Items |
Consider the scope on UTC + External damage major inspection in the functional location PAZ/FPSOT/OIL/LOAD /IPN-_HL-TO25-04-D03P, the given unit name of Hydrocarbon liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOT/GAS/COMP /IPN-_HG-TO31-17-L23N, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/CRS/AIR /TO-PSV-079151, the given unit name of SUBSEA HPU PUMP 1 PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on PSD Replacement in the functional location CLV/BUOY /CRS/AIR /OB-PRV-07208, the given unit name of HYDRAULIC OIL SUPPLY PRESS. SAFE. VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Major Non Intrusive Insp 6-DA-00930B in the functional location DAL/FPSOT/WAT/WINJ /6-DA-00930B, the given unit name of ENG. CLEANING TANK, GT WATER INJT. PUMP, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/OIL/METER/TO-TSV-26153B, the given unit name of FISCAL METERING PACK. TEMP. SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Major Non Intrusive Insp IF703A in the functional location GIR/FPSOT/WAT/WINJ /IF703A, the given unit name of MULTIMEDIA FILTER (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Major Non Intrusive Insp 5-DA-1156A in the functional location DAL/FPSOH/ELE/PWG /5-DA-1156A, the given unit name of STARTING AIR VESSEL, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on Overhaul in the functional location PAZ/FPSOT/WAT/WDEOX/TO-PSV-530525C, the given unit name of OUTLET PUMP C PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Overhaul in the functional location PAZ/FPSOT/OIL/SEP /TO-PSV2-20145B, the given unit name of TO V-2011B PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on METH_Visual inspection of complet struct in the functional location GIR/FPSOT/HSG/STRUC/MOD METHANOL, the given unit name of STRUCTURAL MODULE METHANOL fr 52-56, the corresponding item class discipline would be | Structure |
Consider the scope on Major Non intrusive inspect 5-TA-1811 in the functional location DAL/FPSOH/COF/FO /5-TA-1811, the given unit name of EMERGENCY GENERATOR DAY TANK, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on External damage major inspection in the functional location DAL/FPSOT/COF/CHEM /IPN-_DF-0619-04-G580, the given unit name of LINE GROUP,METHANOL,DRAIN,SS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on PSV-Replace/Scrap in the functional location PAZ/FPSOT/COF/CHEM /TO-PSV-750544, the given unit name of PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on SCD + External damage major inspection in the functional location PAZ/FPSOT/HSG/UPWAT/IPN-_TW-TO85-01-B49, the given unit name of Demineralised water piping group, the corresponding item class discipline would be | Piping |
Consider the scope on Major Non Intrusive Insp 6-DS-5210B in the functional location DAL/FPSOT/GAS/COMP /6-DS-5210B, the given unit name of SUCTION SCRUBBER, 1ST STAGE HP COMPRES., the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on GIR/41-TSV-1784_Scrap/Change in the functional location GIR/FPSOT/COF/CHEM /41-TSV-1784, the given unit name of THERMAL SAFETY VALVE, METHANOL TUTU P70, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on SCD + External damage major inspection in the functional location DAL/FPSOT/OIL/SEP /IPN-_NH-0631-01-D48, the given unit name of LINE GROUP,OIL 1ST,OIL,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on Intrusive Major Inspection in the functional location PAZ/FPSOT/OIL/METER/TO-VZ-2601C, the given unit name of CRUDE OIL METERING FILTER, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on UTC + External damage major inspection in the functional location DAL/FPSOT/OIL/SEP /IPN-_NG-0631-07-B513, the given unit name of LINE GROUP,OIL 1ST,GAS,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on PAZ/ WEIGHT SCALE inspection/ Campaign in the functional location PAZ/FPSOT, the given unit name of PAZFLOR Topsides, the corresponding item class discipline would be | Campaign |
Consider the scope on Replace/Scrap in the functional location PAZ/FPSOT/WAT/WFLT /TO-PSV-512531A, the given unit name of DOSING SYSTEM PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Major Intrusive Major Inspection in the functional location CLV/FPSOT/GAS/COMP /TO-EM-3150B, the given unit name of HP3 COMPRESSOR DISCHARGE COOLER B, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on External damage major inspection in the functional location PAZ/FPSOH/HSG/STRUC/IPN-_AS-HU86-01-_03, the given unit name of Sounding piping group, the corresponding item class discipline would be | Piping |
Consider the scope on TA043/FU Tank Intermediate Survey in the functional location GIR/FPSOH/HSG/STRUC/TA043, the given unit name of WATER BALLAST 6 PORT (T), the corresponding item class discipline would be | FU Items |
Consider the scope on Intrusive Major Inspection in the functional location PAZ/FPSOT/WAT/WFLT /TO-VF-5110A, the given unit name of SEAWATER COARSE FILTRATION UNIT, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on Major Non Intrusive Insp TA971 in the functional location GIR/FPSOT/COF/INERT/TA971, the given unit name of DIESEL OIL TANK FOR GENERATION N2 (V), the corresponding item class discipline would be | Non Structural Tank |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.