{ "ToolName": "デジタルテスター", "Size": "", "ToolOther": "", "WorkName": "電源電圧測定", "WorkItems": [ "■1. 下記個所の電圧を測定する" ], "WorkPoints": [ "判定基準 T111/T112/T113 : 24.5~25.0V T121 : 48.0~49.0V", "T111", "プラス", "マイナス", "T112", "T121", "プラス",...
{ "QualityItem": "電圧確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "T111:24.0~25.0VT112:24.0~25.0VT121:48.0~49.0V", "Method": "デジタルテスター", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "周辺機器確認", "WorkItems": [ "■1. 設備電源ON時にFAN吹き出し方向の確認をする" ], "WorkPoints": [ "手をかざして確認する", "架台下に手をかざして確認する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "内部吸気 方向 G112", "内部吸気...
{ "QualityItem": "方向確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りの排気方向に噴出している事", "Method": "手感", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "キーボード", "Size": "", "ToolOther": "", "WorkName": "SDカードリーダードライブ確認①", "WorkItems": [ "2. 設備電源をONし、ブートローダが起動に失敗した画面で 停止 していることを確認する", "6. 《Floppy Disk Drive》 が(A:)ドライブの場合は「SD-EJM8EH2-009」初期セットアップ作業を実施する (A:)以外のドライブが設定されている場合は「SD-EJM8EH2-008」SDカードリーダードライブ確認②を実施する"...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "キーボード", "Size": "", "ToolOther": "", "WorkName": "SDカードリーダードライブ確認②", "WorkItems": [ "1. ↑・↓を押し、《Local Disk (C:) 》 を選択して、Enterを押す", "2. ↑・↓を押し、フォルダー 《pfsc》 を選択して、Enterを押す", "3. ↑・↓を押し、ファイル 《chgbdtoa.bat》 を選択して、Enterを押す", "4. Back Spaceを2回押して、最初の表示に戻す", "5. 《F...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定する事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "キーボードセットアップ用SD", "Size": "", "ToolOther": "", "WorkName": "初期セットアップ(システムアップデート)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B01" ] }
{ "QualityItem": "セットアップ確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスクセットアップ用SD", "Size": "", "ToolOther": "", "WorkName": "ソフトアップデート(ファームウェアアップデート)", "WorkItems": [ "1. 設備を立ち上げ下記メッセージが表示されたら、㉖をSDドライブに挿入し確認を押す", "2. ソフトアップデート画面に遷移するので環境バックアップを押す", "3. SDを㉖から㉗に入替えてアップデートを押す", "5. アップデート完了後、画面指示に従い設備を再起動する", "4. 全てのフ...
{ "QualityItem": "アップデート確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りアップデートする事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスクソフトライセンス用SD", "Size": "", "ToolOther": "", "WorkName": "ソフトライセンス登録", "WorkItems": [ "1. ㉖を挿入し、サービスエンジニアに切替える", "2. 設定変更メッセージ確認後、画面指示に従い設備を再起動する" ], "WorkPoints": [ "①スクロールして 《全体》 を選択", "③ ㉖を抜いて㉗を挿入後《SD》を押す", "②スクロールして 《ライセンス》 を選択" ], "Tolks": [...
{ "QualityItem": "登録・表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り登録・表示されている事", "Method": "目視", "RecordMethod": "WETE-G002-A03", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスク", "Size": "", "ToolOther": "", "WorkName": "ソフトバージョンマッチング確認", "WorkItems": [ "1. ㉖を挿入し、《ソフトバージョン情報》 画面にて、別紙検査表通りであるか確認する" ], "WorkPoints": [ "※別紙検査表「出荷システム組み合わせ検査表」にて確認すること", "①スクロールして 《システム》 を選択", "②スクロールして 《ソフトバージョン情報》 を選択" ], "Tolks": [], ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "逆相電源ケーブル", "Size": "", "ToolOther": "FM-2884", "WorkName": "1次電源位相接続状態確認", "WorkItems": [ "1. 逆相電源ケーブルが接続されていることを確認する", "2. 入出力画面アドレス0001 ビット5がOFFしていることを確認する", "4. 設備電源をONし、入出力画面アドレス0001 ビット5がONしていることを確認する", "3. 設備電源をOFFし、逆相電源ケーブルを取外す" ], "WorkPoints": [ ...
{ "QualityItem": "接続確認", "ToolManageNo": "FM-2884", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "1次電源位相接続状態確認", "WorkItems": [ "1. 逆相電源ケーブルが接続されていることを確認する", "2. 入出力画面アドレス0001 ビット5がOFFしていることを確認する", "4. 設備電源をONし、入出力画面アドレス0001 ビット5がONしていることを確認する", "3. 設備電源をOFFし、逆相電源ケーブルを取外す" ], "WorkPoints": [ "①スクロールして 《調...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前後タッチパネル確認", "WorkItems": [ "2. 前後のタッチパネル操作時にズレが無いことを確認する(ズレ発生時は下記手順でキャリブを実施する)", "1. 前後のタッチパネルにノイズ・色モレ等無いことを目視確認する" ], "WorkPoints": [ "初期画面に戻る" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [],...
{ "QualityItem": "外観確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "ノイズ・色モレ無き事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前後タッチパネル確認", "WorkItems": [ "2. 前後のタッチパネル操作時にズレが無いことを確認する(ズレ発生時は下記手順でキャリブを実施する)", "1. 前後のタッチパネルにノイズ・色モレ等無いことを目視確認する" ], "WorkPoints": [ "初期画面に戻る" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [],...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側タッチパネルカラー調整", "WorkItems": [ "1. 後側タッチパネルのカラー調整を実施する" ], "WorkPoints": [ "後側のみ実施すること", "③ カラー調整を自動で実施", "初期画面に戻る" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "① 《\u002B...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前後タッチパネル操作確認", "WorkItems": [ "2. エンジニアモードへの切替が可能なことを確認する", "3. 前側点灯時、後側タッチパネル操作が無効であることを確認する", "5. 後側タッチパネルを押下し、手順1~4を実施する", "4. オペレーターモードに戻す", "1. 前側タッチパネルの Selected View ランプが点灯していることを確認する(点灯無時はタッチパネルを押下する)"...
{ "QualityItem": "点灯確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "SelectedViewランプが点灯する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前後タッチパネル操作確認", "WorkItems": [ "2. エンジニアモードへの切替が可能なことを確認する", "3. 前側点灯時、後側タッチパネル操作が無効であることを確認する", "5. 後側タッチパネルを押下し、手順1~4を実施する", "4. オペレーターモードに戻す", "1. 前側タッチパネルの Selected View ランプが点灯していることを確認する(点灯無時はタッチパネルを押下する)"...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "モード切替が正常に動作する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスク", "Size": "", "ToolOther": "", "WorkName": "時刻合わせ", "WorkItems": [ "2. 画面印刷SD出力を《ON》設定する", "3. 任意の時刻・日付に設定する", "1. ㉖を挿入し、サービスエンジニアに切替える" ], "WorkPoints": [ "③スクロールして 《動作スイッチ》 を選択", "②スクロールして 《全体》 を選択", "①スクロールして 《モニター表示》 を選択" ], "Tolks": [...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定し指示通り表示されている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスク", "Size": "", "ToolOther": "", "WorkName": "下受けピン自動交換ソフトスイッチ確認(オプション)", "WorkItems": [ "2. データ保存終了後、画面指示に従い設備を再起動する", "1. ㉖を挿入し、サービスエンジニアに切替える" ], "WorkPoints": [ "《サービスエンジニア》 を選択", "② 《下矢印》 を押し次頁へ", "① 《ホーム》 を選択", "《下受けピン自動交換》の《ON》 を選択" ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定する事", "Method": "目視", "RecordMethod": "WETE-G002-A03", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マシンシリアル入力・立ち上げ日確認", "WorkItems": [ "1. マシンシリアル番号を入力し、立ち上げ日が変更されていることを確認する" ], "WorkPoints": [ "②スクロールして 《ソフトバージョン情報》 を選択" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "①スクロールして 《システ...
{ "QualityItem": "入力・表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定し指示通り表示されている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "本体構成データ設定", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B01" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "各ボード電圧・温度表示確認", "WorkItems": [ "1. 画面表示された温度・電圧値を確認する" ], "WorkPoints": [ "電圧値・温度表示を確認し、検査書にレチェックを記入する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "①スクロールして 《全体》 を選択", "第 2 階...
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り表示されている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "メイン圧力スイッチ設定①", "WorkItems": [ "1. メイン圧力SWの初期設定を行う" ], "WorkPoints": [ "メイン圧力SW", "1秒間表示", "1秒間表示", "応答時間設定", "1秒間表示", "表示色設定", "動作設定", "NO/NC設定", "1秒間表示", "初期表示に戻る", "初期表示に戻る", ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定する事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "メイン圧力スイッチ設定②", "WorkItems": [ "1. メイン圧力SWの初期設定を行う", "2. メイン圧用のレギュレータで規格値内の圧力に調整する" ], "WorkPoints": [ "1秒間表示", "1秒間表示", "1秒間表示", "1秒間表示", "初期表示に戻る", "キーロック設定", "しきい値設定", "設定完了", "調整後...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "0.5~0.51MPa", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "真空破壊圧デジタルゲージ設定①", "WorkItems": [ "1. 真空破壊圧デジタルゲージの初期設定を行う" ], "WorkPoints": [ "1秒間表示", "NO/NC設定", "1秒間表示", "1秒間表示", "応答時間設定", "1秒間表示", "表示色設定", "初期表示に戻る", "設定完了", "動作設定", ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定する事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "真空破壊圧デジタルゲージ設定②", "WorkItems": [ "1. 真空破壊圧デジタルゲージの初期設定を行う" ], "WorkPoints": [ "しきい値設定", "1秒間表示", "1秒間表示", "キーロック設定", "1秒間表示", "1秒間表示", "初期表示に戻る", "設定完了" ], "Tolks": [], "Inspec...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "レギュレータ調整", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B01" ] }
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "8~12KPa0.13~0.14MPa0.4MPa", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "XYエンコーダ誤接続確認", "WorkItems": [ "1. フロント側のX軸を右へ、Y軸を奥へ移動させた時、現在位置が\u002B方向へ増加するか確認する", "2. リア側に切替え同様に確認する" ], "WorkPoints": [ "X軸確認", "Y軸確認", "① 《Front》 を選択" ], "Tolks": [], "InspectionNo": "", "Inspecti...
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り表示されている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "真空ポンプ動作確認", "WorkItems": [ "2. 真空ポンプを動作させたまま、パワーユニットのサーマルスイッチのアクリルカバーを開け白ボタンをマイナスドライバー等で左にスライドさせた時、 真空ポンプが停止し、入出力画面アドレス0044 ビット6がONすることを確認する", "1. 真空ポンプを入出力画面アドレス0024 ビット6にてONさせて、リークが無いことを確認する。又、ゲージにて真空圧を目視確認する", ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "-87~-100kPa", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "真空ポンプ動作確認", "WorkItems": [ "2. 真空ポンプを動作させたまま、パワーユニットのサーマルスイッチのアクリルカバーを開け白ボタンをマイナスドライバー等で左にスライドさせた時、 真空ポンプが停止し、入出力画面アドレス0044 ビット6がONすることを確認する", "1. 真空ポンプを入出力画面アドレス0024 ビット6にてONさせて、リークが無いことを確認する。又、ゲージにて真空圧を目視確認する", ...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "認識カメラLED確認", "WorkItems": [ "1. ヘッドカメラのLED照明が点灯し、カメラの画像が指示通り表示されることを確認する", "2. ヘッド基板カメラを熱補正認識マークが映る位置に移動する", "3. リア側に切替え、同様に確認する" ], "WorkPoints": [ "②\uF075押す→ 《NORM》 → 《FINE》 に変更", "①▼押す→ 《ANSWER》 に変更 (左に〇が移動)...
{ "QualityItem": "点灯・表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り点灯・表示する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "文字認識カメラLED確認①(オプション)", "WorkItems": [ "1. 構成情報表示確認" ], "WorkPoints": [ "仕様ヘッド側にヘッドカメラ照明(文字認識)が表示されているか確認する" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "① 《全体》 を選択", "② 《構成情報...
{ "QualityItem": "表示確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り表示されている事", "Method": "目視", "RecordMethod": "WETE-G002-A03", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "文字認識カメラLED確認②(オプション)", "WorkItems": [ "1. 文字認識用LED照明の点灯確認を行う", "2. リア側仕様有時は画面切替えし、同様に確認する" ], "WorkPoints": [ "ACTIVATION SW", "②各ランプ(LAMP 5種)の輝度数値(0 (暗) ~255 (明) )を順に切替え点灯状態が変化することを確認する", "①ランプ切替(LAMP 5種)し、カメラ...
{ "QualityItem": "点灯確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り点灯する事", "Method": "目視", "RecordMethod": "WETE-G002-A03", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスクI/O自動化用SD", "Size": "", "ToolOther": "", "WorkName": "I/O自動化用システムアップデート", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [] }
{ "QualityItem": "アップデート確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りアップデートする事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "REX-BT60RS232C通信/連結信号確認ケーブル", "Size": "", "ToolOther": "", "WorkName": "設備へのセッティング", "WorkItems": [ "接続構成", "1. 設備と㉖㉗接続", "2. ㉘を接続" ], "WorkPoints": [ "CNDUP接続", "CNDUS接続", "-XP接続", "-XS接続" ], "Tolks": [], "InspectionNo": "", "Inspecti...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続する事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ノートPC", "Size": "", "ToolOther": "", "WorkName": "自動化ツール立ち上げ", "WorkItems": [ "1. 電子版検査書を開き、 他 → I/O自動検査をクリック", "2. IOチェックの項目選択", "3. デフォルト状態チェック" ], "WorkPoints": [ "※電子版検査書を立ち上げる前に、 REX-BT60 の電源ONを確認のこと", "GW", "2F", "GW" ], "To...
{ "QualityItem": "セットアップ確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "表示灯・ブザー関連チェック", "WorkItems": [ "1. ①をタッチ", "2. 状態変化の目視確認実施", "3. 全項目にて目視確認実施後OKをタッチ、全項目のOK表示を確認後、①をタッチ" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "初期状態チェック中",...
{ "QualityItem": "出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前側確認①", "WorkItems": [ "3. 状態変化を手動にて実施", "1. ①をタッチ", "4. 入力OKで下記メッセージを表示するので①をタッチ", "2. 下記メッセージを表示するので①をタッチ", "5. 状態変化の目視確認実施" ], "WorkPoints": [ "FRONT" ], "Tolks": [], "InspectionNo": "", "Ins...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前側確認②", "WorkItems": [ "1. 状態変化を手動にて実施", "3. 入力OKで下記メッセージを表示するので①をタッチ", "2. 状態変化を手動にて実施", "4. 状態変化の目視確認実施" ], "WorkPoints": [ "FRONT" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Wor...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前側確認③", "WorkItems": [ "2. 入力OKで下記メッセージを表示するので①をタッチ", "1. 状態変化を手動にて実施", "4. 状態変化を手動にて実施", "3. 状態変化の目視確認実施" ], "WorkPoints": [ "FRONT" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Wor...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前側確認④", "WorkItems": [ "3. 状態変化を手動にて実施", "1. 状態変化を手動にて実施", "F 安全カバーを開ける", "搬送開口部センサ(左)を画面変化する迄遮光 →OKで搬送開口部センサ(右)を画面変化する迄遮光", "2. 状態変化を手動にて実施" ], "WorkPoints": [ "FRONT", "F 安全カバー" ], "Tolks":...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前側確認⑤", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前側確認⑥", "WorkItems": [ "2. 最終項目入力OK確認後、①をタッチ", "1. 状態変化を手動にて実施" ], "WorkPoints": [ "F2(右側)", "F2(右側)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "1S3711P", "FRONT", ...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "F1(左側)交換台車対応ユニット有無検出確認", "WorkItems": [ "4. 入力OK確認後、①をタッチ", "1. ①をタッチ", "2. 下記メッセージを表示するので①をタッチ", "3. 状態変化を手動にて実施" ], "WorkPoints": [ "F1(左側)", "※トレイ固定仕様時は確認無", "F1(左側)", "トレイ固定仕様時" ], "Tolks...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ILK及び台車ショートコネクタ", "Size": "", "ToolOther": "FE-0319FM-2962", "WorkName": "F1(左側)供給部ILK確認", "WorkItems": [ "F1 台車接続部に㉖を挿入", "2. 状態変化を手動にて実施", "1. ①をタッチ", "3. 入力OK確認後、①をタッチ" ], "WorkPoints": [ "17・34連仕様", "F1:台車接続", "F2:台車接続", "F1:台車接続", "※ト...
{ "QualityItem": "入力確認", "ToolManageNo": "FE-0319FM-2962", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ILK及び台車ショートコネクタ", "Size": "", "ToolOther": "FE-0319FM-2962", "WorkName": "F2(右側)供給部ILK確認", "WorkItems": [ "F2 台車接続部に㉖を挿入", "2. 状態変化を手動にて実施", "1. ①をタッチ", "3. 入力OK確認後、①をタッチ" ], "WorkPoints": [ "17・34連仕様", "F1:台車接続", "F2:台車接続", "※30・60連仕様時は確認無", ...
{ "QualityItem": "入力確認", "ToolManageNo": "FE-0319FM-2962", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ILK及び台車ショートコネクタ", "Size": "", "ToolOther": "FE-0319FM-2962", "WorkName": "F1(左側)台車確認", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入出力確認", "ToolManageNo": "FE-0319FM-2962", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ILK及び台車ショートコネクタ", "Size": "", "ToolOther": "FE-0319FM-2962", "WorkName": "F2(右側)台車確認", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入出力確認", "ToolManageNo": "FE-0319FM-2962", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "Fチェンジャ入力確認", "WorkItems": [ "2. ①をタッチ", "3. 状態変化を手動にて実施", "4. 入力OK確認後、①をタッチ", "1. F側のノズルチェンジャを外す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "初期状態チェック中",...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "Fチェンジャ出力確認", "WorkItems": [ "このメッセージにて再初期状態確認中", "上昇・下降動作の入力信号も自動検査する", "開閉動作の入力信号も自動検査する", "2. 状態変化の目視確認実施", "3. 状態変化の目視確認実施", "4. 全項目のOK表示確認後、①をタッチ", "5. Fチェンジャ出力迄の完了表示確認", "1. ①をタッチ", "自動検査実行中"...
{ "QualityItem": "出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "搬送用基板240×216", "Size": "", "ToolOther": "", "WorkName": "L1/L2搬送確認①", "WorkItems": [ "初期動作実行中", "1. L1/L2選択→①をタッチ", "2. ①をタッチ", "3. 下記メッセージを表示するので①をタッチ", "4. 搬送用基板を投入", "自動検査が始まる" ], "WorkPoints": [ "※シングルコンベア仕様時は1枚にて実施", "※シングルコンベア仕様時は L1...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "搬送用基板240×216", "Size": "", "ToolOther": "", "WorkName": "L1/L2搬送確認②", "WorkItems": [ "2. 全項目のOK表示確認後、基板を取除き①をタッチ", "3. 完了表示確認", "1. 状態変化の確認", "自動検査実行中", "自動検査実行中", "自動検査実行中", "L1/2(♯1/2) 共に基板下受けが自動で上昇/下降することを目視確認", "L1/2 基板検出センサ2 (右待機/右延...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "SIG1/2確認", "WorkItems": [ "1. SIG1/SIG2選択→①をタッチ", "2. ①をタッチ", "3. 状態変化の確認", "4. 全項目のOK表示確認後、①をタッチ", "5. 完了表示確認", "自動検査実行中", "自動検査実行中", "自動検査実行中" ], "WorkPoints": [ "※画像はデュアルコンベア仕様時", "※シ...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "瞬停リセット確認", "WorkItems": [ "入力信号も自動検査する", "1. 瞬停リセット選択→①をタッチ", "2. ①をタッチ", "3. 状態変化の確認", "5. 全項目のOK表示確認後、①をタッチ", "4. 状態変化の確認" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側確認①", "WorkItems": [ "2. 下記メッセージを表示するので①をタッチ", "1. ①をタッチ", "4. 状態変化を手動にて実施", "5. 状態変化を手動にて実施", "3. 状態変化の確認", "確認済なので OK をタッチ", "6. SD-EJM2FH2-049-1に進む" ], "WorkPoints": [ "REAR", "FRONT" ...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側確認②", "WorkItems": [ "4. 状態変化を手動にて実施", "2. 状態変化の目視確認実施", "3. 状態変化を手動にて実施", "5. 入力OKで下記メッセージを表示するので①をタッチ", "6. 状態変化の目視確認実施", "1. SD-EJM2FH2-051-6の続き:入力OKで下記メッセージを表示するので①をタッチ" ], "WorkPoints": [ "REAR"...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側確認③", "WorkItems": [ "1. 状態変化を手動にて実施", "2. 入力OKで下記メッセージを表示するので①をタッチ", "3. 状態変化の目視確認実施", "4. 状態変化を手動にて実施" ], "WorkPoints": [ "REAR" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Word...
{ "QualityItem": "入出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側確認④", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側確認⑤", "WorkItems": [ "1. 状態変化を手動にて実施", "2. 状態変化を手動にて実施" ], "WorkPoints": [ "R2(右側)", "R2(右側)" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "検査表①:I/Oチェックリスト", "取外し", ...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側確認⑥", "WorkItems": [ "1. 状態変化を手動にて実施", "2. 状態変化を手動にて実施", "5. 状態変化を手動にて実施", "6. 状態変化を手動にて実施", "3. 状態変化を手動にて実施", "4. 状態変化を手動にて実施" ], "WorkPoints": [ "※左からFAN A/B/C/D/E/F" ], "Tolks": [], "Inspec...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側確認⑦", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "後側確認⑧", "WorkItems": [ "1. 状態変化を手動にて実施", "2. 最終項目入力OK確認後、①をタッチ" ], "WorkPoints": [ "REAR" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "R サーボ SW", "R サーボ SWをON→OFF 画...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "R1(左側)交換台車対応ユニット有無検出確認", "WorkItems": [ "4. 入力OK確認後、①をタッチ", "1. ①をタッチ", "2. 下記メッセージを表示するので①をタッチ", "3. 状態変化を手動にて実施" ], "WorkPoints": [ "R1(左側)", "※トレイ固定仕様時は確認無", "R1(左側)", "トレイ固定仕様時" ], "Tolks...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ILK及び台車ショートコネクタ", "Size": "", "ToolOther": "FE-0319FM-2962", "WorkName": "R1(左側)供給部ILK確認", "WorkItems": [ "R1 台車接続部に㉖を挿入", "2. 状態変化を手動にて実施", "1. ①をタッチ", "3. 入力OK確認後、①をタッチ" ], "WorkPoints": [ "17・34連仕様", "R1:台車接続", "R2:台車接続", "R1:台車接続", "※ト...
{ "QualityItem": "入力確認", "ToolManageNo": "FE-0319FM-2962", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ILK及び台車ショートコネクタ", "Size": "", "ToolOther": "FE-0319FM-2962", "WorkName": "R2(右側)供給部ILK確認", "WorkItems": [ "2. 状態変化を手動にて実施", "1. ①をタッチ", "3. 入力OK確認後、①をタッチ", "R2 台車接続部に㉖を挿入" ], "WorkPoints": [ "17・34連仕様", "R1:台車接続", "R2:台車接続", "※30・60連仕様時は確認無", ...
{ "QualityItem": "入力確認", "ToolManageNo": "FE-0319FM-2962", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ILK及び台車ショートコネクタ", "Size": "", "ToolOther": "FE-0319FM-2962", "WorkName": "R1(左側)台車確認", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入出力確認", "ToolManageNo": "FE-0319FM-2962", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ILK及び台車ショートコネクタ", "Size": "", "ToolOther": "FE-0319FM-2962", "WorkName": "R2(右側)台車確認", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入出力確認", "ToolManageNo": "FE-0319FM-2962", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "Rチェンジャ入力確認", "WorkItems": [ "2. ①をタッチ", "3. 状態変化を手動にて実施", "4. 入力OK確認後、①をタッチ", "1. F側のノズルチェンジャを外す" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "初期状態チェック中",...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "Rチェンジャ出力確認", "WorkItems": [ "2. 状態変化の目視確認実施", "3. 状態変化の目視確認実施", "4. 全項目のOK表示確認後、①をタッチ", "5. 全ての完了表示確認後、①をタッチ", "1. ①をタッチ", "上昇・下降動作の入力信号も自動検査する", "このメッセージにて再初期状態確認中", "開閉動作の入力信号も自動検査する", "自動検査実行中",...
{ "QualityItem": "出力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り作業出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスクセットアップ用SD", "Size": "", "ToolOther": "", "WorkName": "標準システムアップデート", "WorkItems": [ "2. アップデート完了後、画面指示に従い設備を再起動する", "1. 標準システムをアップデートする" ], "WorkPoints": [ "㉖を挿入後 《ログオン》 を押す", "サービスエンジニアに切り替える", "㉗を挿入後 《SD》 を押す" ], "Tolks": [], "Ins...
{ "QualityItem": "アップデート確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通りアップデートする事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスクカッター部開口確認治具", "Size": "", "ToolOther": "FM-3226", "WorkName": "F1テープカッタ(17・34連台車仕様)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "出力確認", "ToolManageNo": "FM-3226", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "カッター部開口確認治具", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "カッター部開口確認治具", "Size": "", "ToolOther": "FM-3226", "WorkName": "F2テープカッタ(17・34連台車仕様)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "出力確認", "ToolManageNo": "FM-3226", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "カッター部開口確認治具", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスクカッター部開口確認治具", "Size": "", "ToolOther": "FM-3226", "WorkName": "Fテープカッター①(30・60連台車仕様)", "WorkItems": [ "2. 台車を挿入する", "1. ショートコネクタを外す", "3. 操作パネル左の 《EXCHANGE》 を長押しし、台車を接続する", "7. 台車に治具を挿入し、下記状態になることを確認する", "4. ㉖を挿入し、サービスエンジニアに切替える", "6. を押しながら入出力画面アドレ...
{ "QualityItem": "出力確認", "ToolManageNo": "FM-3226", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "カッター部開口確認治具", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "カッター部開口確認治具", "Size": "", "ToolOther": "FM-3226", "WorkName": "Fテープカッター②(30・60連台車仕様)", "WorkItems": [ "4. を押しながら入出力画面アドレス00A0 ビット1をOFFにする", "5. を押しながら入出力画面アドレス01E0 ビット1をOFFにする", "3. 台車に治具を挿入し、下記状態になることを確認する", "1. アドレス00A0 ビット1はON状態のままアドレス01E0 ビット1を表示させる",...
{ "QualityItem": "出力確認", "ToolManageNo": "FM-3226", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "カッター部開口確認治具", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "カッター部開口確認治具", "Size": "", "ToolOther": "FM-3226", "WorkName": "R1テープカッタ(17・34連台車仕様)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "出力確認", "ToolManageNo": "FM-3226", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "カッター部開口確認治具", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "カッター部開口確認治具", "Size": "", "ToolOther": "FM-3226", "WorkName": "R2テープカッタ(17・34連台車仕様)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "出力確認", "ToolManageNo": "FM-3226", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "カッター部開口確認治具", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "カッター部開口確認治具", "Size": "", "ToolOther": "FM-3226", "WorkName": "Rテープカッター①(30・60連台車仕様)", "WorkItems": [ "2. 台車を挿入する", "1. ショートコネクタを外す", "3. 操作パネル左の 《EXCHANGE》 を長押しし、台車を接続する", "5. を押しながら入出力画面アドレス00A0 ビット5をONにする", "6. 台車に治具を挿入し、下記状態になることを確認する", "4. 番号順に選択し...
{ "QualityItem": "出力確認", "ToolManageNo": "FM-3226", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "カッター部開口確認治具", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "カッター部開口確認治具", "Size": "", "ToolOther": "FM-3226", "WorkName": "Rテープカッター②(30・60連台車仕様)", "WorkItems": [ "4. を押しながら入出力画面アドレス00A0 ビット5をOFFにする", "3. 台車に治具を挿入し、下記状態になることを確認する", "1. アドレス00A0 ビット5はON状態のままアドレス01E0 ビット5を表示させる", "2. を押しながら入出力画面アドレス01E0 ビット5をONにする", "...
{ "QualityItem": "出力確認", "ToolManageNo": "FM-3226", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "カッター部開口確認治具", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ラインSWBOX", "Size": "", "ToolOther": "FM-2460", "WorkName": "隣接装置安全入力確認", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入力確認", "ToolManageNo": "FM-2460", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "基板ホルダ高さ検出センサ動作確認治具", "Size": "", "ToolOther": "FM-6723", "WorkName": "基板ホルダ位置検出①", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入力確認", "ToolManageNo": "FM-6723", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "基板ホルダ高さ検出センサ動作確認治具", "Size": "", "ToolOther": "FM-6723", "WorkName": "基板ホルダ位置検出②", "WorkItems": [ "1. 入出力画面アドレス0041 ビット5のON/OFFを確認", "2. 入出力画面アドレス0084 ビット3のON/OFFを確認", "3. 入出力画面アドレス01C3 ビット2のON/OFFを確認", "4. 入出力画面アドレス01C3 ビット4のON/OFFを確認", "5. 入出力画面アドレス01C...
{ "QualityItem": "入力確認", "ToolManageNo": "FM-6723", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "真空ポンプ冷却ファン回転パルス", "WorkItems": [ "1. 調整画面にて番号順に選択し確認するアドレスを表示させる", "2. 入出力画面アドレス0043 ビット6のON/OFFを確認" ], "WorkPoints": [ "※真空ポンプ冷却ファン回転パルス信号用コネクタ箇所参考図", "① 《全体》 を選択", "③ 《ch1》 を選択", "④アドレス0043 ビット6を...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスクシリンダロッド戻り防止治具", "Size": "", "ToolOther": "FM-6751", "WorkName": "L1/L2(L/R)搬送レールクランプ解除検出(オプション:延長コンベア)①", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入出力確認", "ToolManageNo": "FM-6751", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "シリンダロッド戻り防止治具", "Size": "", "ToolOther": "FM-6751", "WorkName": "L1/L2(L/R)搬送レールクランプ解除検出(オプション:延長コンベア)②", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入出力確認", "ToolManageNo": "FM-6751", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスク基板検出センサ遮光治具", "Size": "", "ToolOther": "FM-3324", "WorkName": "L1/L2基板検出センサ1・2(実装位置♯2)(オプション:スライド搬送)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入力確認", "ToolManageNo": "FM-3324", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスク", "Size": "", "ToolOther": "", "WorkName": "F1/R1フィーダ安全カバーSW(台車ドッグ識別bit2)(オプション:切替仕様)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "F1/R1トレイ/台車切替ユニット有無(オプション:切替仕様)", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B02" ] }
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスク", "Size": "", "ToolOther": "", "WorkName": "ビーム干渉センサ確認", "WorkItems": [ "5. F/Rのビームを干渉させる", "6. 入出力画面アドレス2C51 ビット4がOFFになることを確認する", "1. ㉖を挿入し、サービスエンジニアに切替える", "3. F/Rのビームを干渉位置から離す", "4. 入出力画面アドレス2C51 ビット4がONになることを確認する", "2. 番号順に選択しアドレス表示させる" ...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B02", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "搬送流れ方向識別確認", "WorkItems": [ "6. 設備電源をOFFする", "1. 設備電源をONし、入出力確認画面にてアドレス0044 ビット2・3の 《搬送流れ方向識別》 が仕様通りになっているか確認する", "2. 設備電源をOFFする", "3. パワーユニットのSIO基板のコネクタを入替える", "4. 設備の電源をONする", "5. 入出力確認画面アドレス0044 ビット2・3の 《搬送...
{ "QualityItem": "入力確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り確認する事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "Fドライバー接続", "WorkItems": [ "1. 設備の電源をOFFし、フロント側X・Y軸ドライバーにパワー線を接続する" ], "WorkPoints": [ "FXドライバー", "CNP3(K501)", "FYドライバー", "CNP3A(K502)", "CNP3B(K502)", "CHARGEランプ点灯中はパワー線の接続は行わないこと" ], "...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続する事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "", "Size": "", "ToolOther": "", "WorkName": "Rドライバー接続", "WorkItems": [ "1. 設備の電源をOFFし、リア側X・Y軸ドライバーにパワー線を接続する" ], "WorkPoints": [ "CNP3(K503)", "CNP3A(K504)", "CNP3B(K504)", "RXドライバー", "RYドライバー", "CHARGEランプ点灯中はパワー線の接続は行わないこと" ], "Tol...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続する事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスク", "Size": "", "ToolOther": "", "WorkName": "原点復帰確認", "WorkItems": [], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "WETE-G002-B01" ] }
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "KEYディスク", "Size": "", "ToolOther": "", "WorkName": "安全テスト(サーボSW)①", "WorkItems": [ "■2. を押しながら開始を押下し原点復帰を実施すると、自己診断異常表示にて動作ができないことを確認する", "1. F側 サーボSWをOFFにする", "■3. R側のサーボSWも同様に確認する" ], "WorkPoints": [ "サーボスイッチオフの表示を確認する", "OFF" ], "Tolks": []...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "安全テスト(交換台車)", "WorkItems": [ "1. F1側の台車ショートコネクタを取外す", "■4. R1側も同様に確認する", "■2. を押しながら開始を押下し原点復帰を実施すると、自己診断異常表示にて動作ができないことを確認する", "■3. F2側も同様に確認する", "■5. R2側も同様に確認する" ], "WorkPoints": [ "発生位置と供給部接続エラーの表示を確...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "安全テスト(開閉カバー)①", "WorkItems": [ "■2. を押しながら開始を押下し原点復帰を実施すると、自己診断異常表示にて動作ができないことを確認する", "1. F側の開閉カバーを開ける", "■3. R側の開閉カバーも同様に確認する" ], "WorkPoints": [ "発生位置とカバーオープンの表示を確認する" ], "Tolks": [], "InspectionNo...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "安全テスト(非常停止)", "WorkItems": [ "■1. を押しながら開始を押下し原点復帰中にF側非常停SWを押すと、設備が即停止\u0026エラー表示されることを確認する", "■2. R側の非常停止SWも同様に確認する" ], "WorkPoints": [ "非常停止スイッチON表示を確認する", "原点復帰中に押す" ], "Tolks": [], "InspectionNo": "",...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "安全テスト(開閉カバー)②", "WorkItems": [ "■1. を押しながら開始を押下し原点復帰中にF側開閉カバーを開けると、設備が即停止\u0026エラー表示されることを確認する", "■2. R側の開閉カバーも同様に確認する" ], "WorkPoints": [ "カバーオープン(発生位置)の表示を確認する" ], "Tolks": [], "InspectionNo": "", "I...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "安全テスト(サーボSW)②", "WorkItems": [ "■1. を押しながら開始を押下し原点復帰中にF側サーボSWをOFFにすると、設備が即停止\u0026エラー表示されることを確認する", "■2. R側のサーボSWも同様に確認する" ], "WorkPoints": [ "サーボスイッチオフ表示を確認する", "OFF", "原点復帰中にOFFにする" ], "Tolks": []...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "安全テスト(フィーダ開口部センサ)", "WorkItems": [ "■1. を押しながら開始を押下し原点復帰中にF側のフィーダ゙開口部センサを遮光すると、 F側設備が即停止\u0026エラー表示されることを確認する", "■2. R側のフィーダ開口部センサも同様に確認する" ], "WorkPoints": [ "※センサ1エラー時の表示(各センサに対応した数字が表示される)", "フィーダ開口...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "ショートコネクタ", "Size": "CNEXR-S", "ToolOther": "FM-2701", "WorkName": "安全テスト(搬送開口部センサ)", "WorkItems": [ "■2. を押しながら開始を押下し原点復帰中に左側搬送開口部センサを遮光すると、設備が即停止\u0026エラー表示されることを確認する", "1. ショートコネクタCNEXLとCNEXRが接続されている事を確認する", "■3. 右側の搬送開口センサも同様に確認する" ], "WorkPoints": [ "延長コン...
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2701", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "ショートコネクタ", "Size": "CNEXR-S", "ToolOther": "FM-2700", "WorkName": "安全テスト(搬送開口部センサ)", "WorkItems": [ "■2. を押しながら開始を押下し原点復帰中に左側搬送開口部センサを遮光すると、設備が即停止\u0026エラー表示されることを確認する", "1. ショートコネクタCNEXLとCNEXRが接続されている事を確認する", "■3. 右側の搬送開口センサも同様に確認する" ], "WorkPoints": [ "延長コン...
{ "QualityItem": "動作確認", "ToolManageNo": "FM-2700", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "下受けピン(長・短)", "Size": "", "ToolOther": "", "WorkName": "安全テスト(下受けピン検出)シングルコンベア仕様", "WorkItems": [ "3. エラー停止後下受けピンを立て換え、レールとピン間に隙間がある事を確認する", "■2. サポートプレートに下受けピンを立て、幅寄せを行った時、検出センサにて即停止することを確認する", "1. サポートプレートに下受けピンを立て手動で幅寄せを行い 検出センサがOFF(緑のみ点灯)することを確認する" ], "...
{ "QualityItem": "動作確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り動作出来ている事", "Method": "目視", "RecordMethod": "WETE-G002-B01", "Other": "-", "ProcessName": "安全工程" }
information_extraction