{ "ToolName": "トルクドライバー", "Size": "No.2", "ToolOther": "80cN・m", "WorkName": "電源部取付", "WorkItems": [ "1. に を挿入しSCREW で取付ける" ], "WorkPoints": [ "・板金と電源の端を合わせる事 ・ネジを真っ直ぐ入れ、無理に締めこま無い事", "挿入", "板金と電源部の端を必ず合わせる事" ], "Tolks": [ "締付トルク 80cN・m" ], "InspectionNo": "...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "80cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.2", "ToolOther": "80cN・m", "WorkName": "フィルタブラケット取付", "WorkItems": [], "WorkPoints": [ "確実に締結されている事" ], "Tolks": [ "締付トルク 80cN・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "80cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "フィルター取付", "WorkItems": [ "1. の間にFILTER を挟み込む", "2. の指定箇所に、1の完成品を挿入する" ], "WorkPoints": [ "・奥まで確実に挿入する事 ・収縮チューブを手前にする事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "PANEL取付", "WorkItems": [ "1. 電源部のP2・CN4コネクタを、 の穴に挿入し取付ける(2箇所)", "2. 電源部ネジ穴と、 の穴位置を確認し、SCREW 締付固定する(5箇所)", "3. 青マーキングをする(5箇所)" ], "WorkPoints": [ "・カチッというまで確実に押し込む事 ・ の取付方向に注意する事", "・ はBOXに対し真っ直ぐ取付ける事 ・無理矢理ネ...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.2", "ToolOther": "80cN・m", "WorkName": "PANEL取付", "WorkItems": [], "WorkPoints": [], "Tolks": [ "締付トルク 80cN・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "80cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "電源配線の接続", "WorkItems": [ "1. の裏面を手前にする", "3. 青マーキングする(2箇所)", "2. の電源ユニットからのP1、J2を、それぞれ指定箇所に差込む" ], "WorkPoints": [ "・指定箇所は写真参照 ・J2配線をP1配線の内側を通すこと ・カチッと音がするまで確実に差込む事" ], "Tolks": [], "InspectionNo": "", ...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.2", "ToolOther": "80cN・m", "WorkName": "COVER取付", "WorkItems": [ "1. の裏面にCOVER をセットし、穴位置を合わせ、SCREW で締付固定する" ], "WorkPoints": [], "Tolks": [ "締付トルク 80cN・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "80cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.2", "ToolOther": "120cN・m", "WorkName": "FAN取付", "WorkItems": [], "WorkPoints": [], "Tolks": [ "締付トルク 120cN・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "120cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "FANコネクタ接続", "WorkItems": [ "1. の指定箇所に、FANコネクタを接続する", "2. 青マーキングをする(1箇所)", "3. 2完成品にCONNECTOR-ACCESSORIES を取付ける" ], "WorkPoints": [ "・指定箇所は写真参照 ・ロックが確実にかかっている事", "取付け向きに注意する事" ], "Tolks": [], "Inspecti...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "FANコネクタ接続", "WorkItems": [ "1. の指定箇所に、FANコネクタを接続する", "2. 青マーキングをする(1箇所)", "3. 2完成品にCONNECTOR-ACCESSORIES を取付ける" ], "WorkPoints": [ "・指定箇所は写真参照 ・ロックが確実にかかっている事", "取付け向きに注意する事" ], "Tolks": [], "Inspecti...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "耐圧試験用治具", "Size": "", "ToolOther": "", "WorkName": "接地抵抗試験", "WorkItems": [ "■8. 同様に接地抵抗試験機のテストプローブを の下記B、Cにも当て6、7の項目を実施する", "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップを治具の黒線側に接続し㉖の電源をONする", "3. の電源をONする", "4. 接地抵抗試験機の『MAIN』ボタンを押し、MAINボタンが点灯している事を確認する", "5. 接地抵...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "単体として出荷する場合実施", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "接地抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "接地抵抗試験", "WorkItems": [ "■8. 同様に接地抵抗試験機のテストプローブを の下記B、Cにも当て6、7の項目を実施する", "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップを治具の黒線側に接続し㉖の電源をONする", "3. の電源をONする", "4. 接地抵抗試験機の『MAIN』ボタンを押し、MAINボタンが点灯している事を確認する", "5. 接地抵...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "単体として出荷する場合実施", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "接地抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "接地抵抗試験", "WorkItems": [ "■8. 同様に接地抵抗試験機のテストプローブを の下記B、Cにも当て6、7の項目を実施する", "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップを治具の黒線側に接続し㉖の電源をONする", "3. の電源をONする", "4. 接地抵抗試験機の『MAIN』ボタンを押し、MAINボタンが点灯している事を確認する", "5. 接地抵...
{ "QualityItem": "接地抵抗確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "10A・10秒間・0.1Ω以下", "Method": "接地抵抗試験機", "RecordMethod": "2LC-JG-15023", "Other": "単体として出荷する場合実施", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐圧試験用治具", "Size": "", "ToolOther": "", "WorkName": "絶縁抵抗試験", "WorkItems": [ "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップ黒を治具の黒線側にクリップ赤を赤線側に接続し㉖の電源をONする", "3. の電源をONする", "4. 耐電圧試験機の『IR』ボタンを押し、IRボタンが点灯している事を確認する", "5. 『STOP』ボタンを押す", "■6. 耐電圧試験機の両端の 『START』ボタンを同...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "単体として出荷する場合実施", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁抵抗試験", "WorkItems": [ "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップ黒を治具の黒線側にクリップ赤を赤線側に接続し㉖の電源をONする", "3. の電源をONする", "4. 耐電圧試験機の『IR』ボタンを押し、IRボタンが点灯している事を確認する", "5. 『STOP』ボタンを押す", "■6. 耐電圧試験機の両端の 『START』ボタ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "単体として出荷する場合実施", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁抵抗試験", "WorkItems": [ "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップ黒を治具の黒線側にクリップ赤を赤線側に接続し㉖の電源をONする", "3. の電源をONする", "4. 耐電圧試験機の『IR』ボタンを押し、IRボタンが点灯している事を確認する", "5. 『STOP』ボタンを押す", "■6. 耐電圧試験機の両端の 『START』ボタ...
{ "QualityItem": "絶縁抵抗確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "DC500V・60秒・20MΩ以上", "Method": "耐電圧絶縁抵抗試験機", "RecordMethod": "2LC-JG-15023", "Other": "20MΩ以上になった時点で打ち切り可", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁耐圧試験", "WorkItems": [ "1. 耐電圧試験機の『ACW』ボタンを押し、ACWボタンが点灯している事を確認する", "2. 『STOP』ボタンを押す", "■3. 耐電圧試験機の両端の 『START』ボタンを同時に押し 測定する", "■4. 正常終了するとブザーが1回 鳴り表示部右上に『PASS』 表示が一瞬出る事を確認する", "■5. 結果を検査書に...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "単体として出荷する場合実施", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁耐圧試験", "WorkItems": [ "1. 耐電圧試験機の『ACW』ボタンを押し、ACWボタンが点灯している事を確認する", "2. 『STOP』ボタンを押す", "■3. 耐電圧試験機の両端の 『START』ボタンを同時に押し 測定する", "■4. 正常終了するとブザーが1回 鳴り表示部右上に『PASS』 表示が一瞬出る事を確認する", "■5. 結果を検査書に...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "ブザー音", "Method": "聴覚", "RecordMethod": "-", "Other": "単体として出荷する場合実施", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁耐圧試験", "WorkItems": [ "1. 耐電圧試験機の『ACW』ボタンを押し、ACWボタンが点灯している事を確認する", "2. 『STOP』ボタンを押す", "■3. 耐電圧試験機の両端の 『START』ボタンを同時に押し 測定する", "■4. 正常終了するとブザーが1回 鳴り表示部右上に『PASS』 表示が一瞬出る事を確認する", "■5. 結果を検査書に...
{ "QualityItem": "絶縁耐圧確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "AC1400V・2秒間・20mA以下", "Method": "耐電圧絶縁抵抗試験機", "RecordMethod": "2LC-JG-15023", "Other": "単体として出荷する場合実施", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "治具ボード", "Size": "", "ToolOther": "", "WorkName": "FANアラーム出力・取付け方向確認", "WorkItems": [ "2. ㉖を のFANに挿入し、羽が回転しない様にする", "1. に㉗を差込み、㉘のプローブを㉗の任意の箇所に接続する" ], "WorkPoints": [ "差込み箇所は一番左側、プローブ接続箇所は写真参照" ], "Tolks": [], "InspectionNo": "", "InspectionItems": []...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "オシロスコープ", "Size": "", "ToolOther": "", "WorkName": "FANアラーム出力・取付け方向確認", "WorkItems": [ "2. ㉖を のFANに挿入し、羽が回転しない様にする", "1. に㉗を差込み、㉘のプローブを㉗の任意の箇所に接続する" ], "WorkPoints": [ "差込み箇所は一番左側、プローブ接続箇所は写真参照" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [...
{ "QualityItem": "出力確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "パルス幅3.0±0.75ms停止時:Highレベル", "Method": "オシロスコープ", "RecordMethod": "2LC-JG-15023", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "FANアラーム出力・取付け方向確認", "WorkItems": [ "2. ㉖を のFANに挿入し、羽が回転しない様にする", "3. の電源をONする", "4. オシロスコープの波形にて 出力がHighレベルである事を確認する", "5. ㉖を抜く", "6. FANの風向きが排気方向に なっているか確認する", "1. に㉗を差込み、㉘のプローブを㉗の任意の箇所に接続する" ], "Wor...
{ "QualityItem": "方向確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り排気されている事", "Method": "目視", "RecordMethod": "2LC-JG-15023", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "出力電圧確認用治具", "Size": "", "ToolOther": "", "WorkName": "出力電圧・バックプレーン電圧確認", "WorkItems": [ "1. のP2コネクタに㉗を接続する", "2. 電源ケーブルを接続し、タッチパネルの電源をOFFする", "3. ㉖のファンクションスイッチを電圧に合わせる", "4. ㉖のプローブを㉗のNo.1、3に当てる", "5. 電圧を測定する", "6. 同様に㉖のプローブを㉗のNo.4(黒)、6(赤)に当て電圧を測定する", ...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "テスター", "Size": "", "ToolOther": "", "WorkName": "出力電圧・バックプレーン電圧確認", "WorkItems": [ "1. のP2コネクタに㉗を接続する", "2. 電源ケーブルを接続し、タッチパネルの電源をOFFする", "3. ㉖のファンクションスイッチを電圧に合わせる", "4. ㉖のプローブを㉗のNo.1、3に当てる", "5. 電圧を測定する", "6. 同様に㉖のプローブを㉗のNo.4(黒)、6(赤)に当て電圧を測定する" ], ...
{ "QualityItem": "出力電圧確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "11.4V~12.6V以内", "Method": "テスター", "RecordMethod": "2LC-JG-15023", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "テスター", "Size": "", "ToolOther": "", "WorkName": "出力電圧・バックプレーン電圧確認", "WorkItems": [ "1. のP2コネクタに㉗を接続する", "2. 電源ケーブルを接続し、タッチパネルの電源をOFFする", "3. ㉖のファンクションスイッチを電圧に合わせる", "4. ㉖のプローブを㉗のNo.1、3に当てる", "5. 電圧を測定する", "6. 同様に㉖のプローブを㉗のNo.4(黒)、6(赤)に当て電圧を測定する" ], ...
{ "QualityItem": "バックプレーン電圧確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "指示電圧各±5%", "Method": "テスター", "RecordMethod": "2LC-JG-15023", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "CPU銘板貼付治具", "Size": "", "ToolOther": "FM-4723", "WorkName": "銘板貼付", "WorkItems": [ "1. の左側面を手前にし、指定箇所に㉖をセットする", "■2. 治具に沿って、LABEL を貼付ける", "■3. 治具に沿って、 を貼付ける", "■4. CPU-BOXシリアルNO、検査書有無を確認し 検査表に記入する" ], "WorkPoints": [ "左側面", "指定箇所は絵参照", "FANの上部...
{ "QualityItem": "貼付け確認", "ToolManageNo": "FM-4723", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り貼付けられている事", "Method": "目視", "RecordMethod": "2LC-JG-15023", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "銘板貼付", "WorkItems": [ "1. の左側面を手前にし、指定箇所に㉖をセットする", "■2. 治具に沿って、LABEL を貼付ける", "■3. 治具に沿って、 を貼付ける", "■4. CPU-BOXシリアルNO、検査書有無を確認し 検査表に記入する" ], "WorkPoints": [ "左側面", "指定箇所は絵参照", "FANの上部と板金の端に合わせる事", ...
{ "QualityItem": "製造番号記録", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "製造番号転記", "Method": "目視", "RecordMethod": "2LC-JG-20005", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "基板の差込", "WorkItems": [ "1. のa部に を、b部に ゙を挿入する" ], "WorkPoints": [ "・入りにくい時は強引に挿入し無い事 ・基板のフックが確実にかかっている事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "検査表 :3.目視検査 各ボード,及びブランクパネ...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "2LC-JG-20005", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.1", "ToolOther": "26cN・m", "WorkName": "基板の締付", "WorkItems": [ "1. の各基板の付属ネジを締付固定する(6箇所)" ], "WorkPoints": [ "青マーキングはし無い事" ], "Tolks": [ "締付トルク 26cN・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [ "検査表 :3.目...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "26cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "セットアップ", "WorkItems": [ "1. の指定箇所に、(CRT、キーボード、マウス、カードリーダー)を接続する", "2. に接続したカードリーダーに、SDカードを挿入する" ], "WorkPoints": [ "・指定箇所は写真参照 ・コネクタは緩まないように固定する事", "CRT", "カードリーダー", "マウス", "キーボード", ...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "手順書2LC-JF-19007", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "カーネルインストール(TYPE-10)", "WorkItems": [ "1. 手順書【2LC-JF-19007】を参照し、カーネルインストールを行う" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "検査表 :3.BIOS・ソフト確認 カーネルバージョン確認 ②CAMIF...
{ "QualityItem": "カーネルバージョン確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "OSのVerが一致する事", "Method": "目視", "RecordMethod": "2LC-JG-20004", "Other": "書込み仕様2LC-JR-23013", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "カーネルインストール(TYPE-10)", "WorkItems": [ "1. 手順書【2LC-JF-19007】を参照し、カーネルインストールを行う" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "検査表 :3.BIOS・ソフト確認 カーネルバージョン確認 ②CAMIF...
{ "QualityItem": "CAMIF2・NCIO2の確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "PCIPNFCADPCIPPREAB", "Method": "目視", "RecordMethod": "2LC-JG-20004", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "カーネルインストール(TYPE-10)", "WorkItems": [ "1. 手順書【2LC-JF-19007】を参照し、カーネルインストールを行う" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "検査表 :3.BIOS・ソフト確認 カーネルバージョン確認 ②CAMIF...
{ "QualityItem": "USB設定の確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "Disabled", "Method": "目視", "RecordMethod": "2LC-JG-20004", "Other": "手順書2LC-JF-19007", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "スケール", "Size": "150㎜", "ToolOther": "", "WorkName": "ライセンスシール貼付け", "WorkItems": [ "1. の指定個所にSOFTWARE-LICENSE SOFTWARE-LICENSE SOFTWARE-LICENSE SOFTWARE-LICENSE を貼付ける" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "10mm"...
{ "QualityItem": "貼付確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示寸法各±0.5㎜", "Method": "スケール", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "耐圧試験用治具", "Size": "", "ToolOther": "", "WorkName": "接地抵抗試験", "WorkItems": [ "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップを治具の黒線側に接続し㉖の電源をONする", "4. の電源をONする", "3. 接地抵抗試験機の『MAIN』ボタンを押し、MAINボタンが点灯している事を確認する", "5. 接地抵抗試験機のテストプローブをAに当てる", "■6. 接地抵抗試験機のSTARTボタンを押し続け測...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "接地抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "接地抵抗試験", "WorkItems": [ "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップを治具の黒線側に接続し㉖の電源をONする", "4. の電源をONする", "3. 接地抵抗試験機の『MAIN』ボタンを押し、MAINボタンが点灯している事を確認する", "5. 接地抵抗試験機のテストプローブをAに当てる", "■6. 接地抵抗試験機のSTARTボタンを押し続け測...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "接地抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "接地抵抗試験", "WorkItems": [ "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップを治具の黒線側に接続し㉖の電源をONする", "4. の電源をONする", "3. 接地抵抗試験機の『MAIN』ボタンを押し、MAINボタンが点灯している事を確認する", "5. 接地抵抗試験機のテストプローブをAに当てる", "■6. 接地抵抗試験機のSTARTボタンを押し続け測...
{ "QualityItem": "接地抵抗確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "10A・10秒間・0.1Ω以下", "Method": "接地抵抗試験機", "RecordMethod": "2LC-JG-20005", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐圧試験用治具", "Size": "", "ToolOther": "", "WorkName": "絶縁抵抗試験", "WorkItems": [], "WorkPoints": [ "接続写真参照", "接続写真", "写真A", "写真A参照" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "■安全作業" ] }
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁抵抗試験", "WorkItems": [ "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップ黒を治具の黒線側にクリップ赤を赤線側に接続し㉖の電源をONする", "4. の電源をONする", "3. 耐電圧試験機の『IR』ボタンを押し、IRボタンが点灯している事を 確認する", "5. 『STOP』ボタンを押す", "■6. 耐電圧試験機の両端の『START』ボタ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁抵抗試験", "WorkItems": [ "1. の指定箇所に、㉗を接続する", "2. テスト用ワニ口クリップ黒を治具の黒線側にクリップ赤を赤線側に接続し㉖の電源をONする", "4. の電源をONする", "3. 耐電圧試験機の『IR』ボタンを押し、IRボタンが点灯している事を 確認する", "5. 『STOP』ボタンを押す", "■6. 耐電圧試験機の両端の『START』ボタ...
{ "QualityItem": "絶縁抵抗確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "DC500V・60秒・20MΩ以上", "Method": "耐電圧絶縁抵抗試験機", "RecordMethod": "2LC-JG-20005", "Other": "20MΩ以上になった時点で打ち切り可", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁耐圧試験", "WorkItems": [ "1. 耐電圧試験機の『ACW』ボタンを押し、ACWボタンが点灯している事を確認する", "2. 『STOP』ボタンを押す", "■3. 耐電圧試験機の両端の 『START』ボタンを 同時に押し測定する", "■4. 正常終了するとブザーが1回鳴り表示部右上 に『PASS』表示が一瞬出る事を確認する", "■5. 結果を検査書に記入する", ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁耐圧試験", "WorkItems": [ "1. 耐電圧試験機の『ACW』ボタンを押し、ACWボタンが点灯している事を確認する", "2. 『STOP』ボタンを押す", "■3. 耐電圧試験機の両端の 『START』ボタンを 同時に押し測定する", "■4. 正常終了するとブザーが1回鳴り表示部右上 に『PASS』表示が一瞬出る事を確認する", "■5. 結果を検査書に記入する", ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "ブザー音", "Method": "聴覚", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "耐電圧絶縁抵抗試験機", "Size": "", "ToolOther": "", "WorkName": "絶縁耐圧試験", "WorkItems": [ "1. 耐電圧試験機の『ACW』ボタンを押し、ACWボタンが点灯している事を確認する", "2. 『STOP』ボタンを押す", "■3. 耐電圧試験機の両端の 『START』ボタンを 同時に押し測定する", "■4. 正常終了するとブザーが1回鳴り表示部右上 に『PASS』表示が一瞬出る事を確認する", "■5. 結果を検査書に記入する", ...
{ "QualityItem": "絶縁耐圧確認", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "日常点検表", "StdVal": "AC1400V・2秒間・20mA以下", "Method": "耐電圧絶縁抵抗試験機", "RecordMethod": "2LC-JG-20005", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エージング試験", "WorkItems": [ "1. に㉖を接続する", "2. Computer - Local Disk(C:) - pfsc - copy Kensa を実行する", "5. エージングを実施する", "3. 電源をOFFする" ], "WorkPoints": [ "電源 OFF", "P10出荷検査ソフト操作手順書(2LC-MN-15001)に準ずる。" ], ...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "エージング試験", "WorkItems": [ "1. に㉖を接続する", "2. Computer - Local Disk(C:) - pfsc - copy Kensa を実行する", "5. エージングを実施する", "3. 電源をOFFする" ], "WorkPoints": [ "電源 OFF", "P10出荷検査ソフト操作手順書(2LC-MN-15001)に準ずる。" ], ...
{ "QualityItem": "設定確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り設定されている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "恒温槽", "Size": "", "ToolOther": "", "WorkName": "エージング試験", "WorkItems": [ "1. に㉖を接続する", "2. Computer - Local Disk(C:) - pfsc - copy Kensa を実行する" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "2LC-JG-20005" ] }
{ "QualityItem": "温度エージング確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "ソフト手順書通りの事50℃/90分", "Method": "目視", "RecordMethod": "2LC-JG-20005", "Other": "ソフト手順書2LC-MN-15001", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "恒温槽", "Size": "", "ToolOther": "", "WorkName": "エージング試験", "WorkItems": [ "1. に㉖を接続する", "2. Computer - Local Disk(C:) - pfsc - copy Kensa を実行する" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "2LC-JG-20005" ] }
{ "QualityItem": "ON/OFFエージング確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "ソフト手順書通りの事50回", "Method": "目視", "RecordMethod": "2LC-JG-20005", "Other": "ソフト手順書2LC-MN-15001", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "基板ホルダ(F)配線・配管接続", "WorkItems": [ "1. 架台下から上がってきた配線・配管をグロメットに通す", "2. コネクタブラケットにホルダー用配線を接続", "3. コネクタ配線の結束" ], "WorkPoints": [ "グロメットに通す際にコネクタの爪の破損に注意", "コネクタ名称 1B1233R", "ピンの破損、抜け等の確認", "配線・配管に負荷がか...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-058", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "3㎜", "ToolOther": "3.2N・m", "WorkName": "開口部センサ取付(前部左)", "WorkItems": [ "1. Y軸フレーム(前側)に①をBOLT WASHER で取付" ], "WorkPoints": [], "Tolks": [ "締付トルク 3.2N・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [ "前側", "後側", "現在の...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.2N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "3㎜", "ToolOther": "3.2N・m", "WorkName": "開口部センサ取付(前部左)", "WorkItems": [ "1. Y軸フレーム(前側)に①をBOLT WASHER で取付" ], "WorkPoints": [], "Tolks": [ "締付トルク 3.2N・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [ "前側", "後側", "現在の...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.2N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "3㎜", "ToolOther": "3.2N・m", "WorkName": "開口部センサ取付・配線(前部右)", "WorkItems": [ "1. Y軸フレーム(前側右)に①をBOLT WASHER で固定" ], "WorkPoints": [], "Tolks": [ "締付トルク 3.2N・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [ "前側", "後側", ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.2N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "3㎜", "ToolOther": "3.2N・m", "WorkName": "開口部センサ取付・配線(前部右)", "WorkItems": [ "1. Y軸フレーム(前側右)に①をBOLT WASHER で固定" ], "WorkPoints": [], "Tolks": [ "締付トルク 3.2N・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [ "前側", "後側", ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.2N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前部右配線", "WorkItems": [ "2. コネクタブラケットに開口部センサ配線", "3. 開口部センサ配線をテープ浮きセンサ配線にインシュロックで固定", "1. テープ浮きセンサブラケットに開口部センサ配線をインシュロックで固定" ], "WorkPoints": [ "配線はテープ浮きブラケットの裏側に引き回す", "コネクタ名称 B1021R", "ピンの破損、抜け等の確認", ...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-058", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前部左配線", "WorkItems": [ "1. テープ浮きセンサブラケットに開口部センサ配線をインシュロックにて固定", "2. コネクタブラケットに開口部センサ配線", "3. 開口部センサ配線をテープ浮きセンサ配線にインシュロックで固定" ], "WorkPoints": [ "配線はテープ浮きブラケットの裏側を引き回すこと", "コネクタ名称 B1020TR", "ピンの破損、抜け等の確...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-058", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "部品廃棄BOXポール取付(F側)", "WorkItems": [ "1. 架台に①を取付" ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "現在の作業位置", "後側", "前側" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "5㎜", "ToolOther": "9.8N・m", "WorkName": "原点ポール取付(F側)", "WorkItems": [], "WorkPoints": [ "ネジ穴センターにて取付" ], "Tolks": [ "締付トルク 9.8N・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [ "前側", "前側" ] }
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "9.8N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "5㎜", "ToolOther": "9.8N・m", "WorkName": "部品廃棄BOXブラケット取付(F側)", "WorkItems": [ "1. 部品廃棄BOXポールに①をBOLT WASHER で取付", "2. 各ポールに部品廃棄BOXセンサ配線をインシュロックにて固定", "3. ①に②を取付" ], "WorkPoints": [ "F側用のセンサ取付け(コネクタ名称 B1212)", "取付けの際、原点ポールとの干渉注意", "配管の...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "9.8N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "部品廃棄BOXブラケット取付(F側)", "WorkItems": [ "1. 部品廃棄BOXポールに①をBOLT WASHER で取付", "2. 各ポールに部品廃棄BOXセンサ配線をインシュロックにて固定", "3. ①に②を取付" ], "WorkPoints": [ "ポールの左側に配線し結束", "F側用のセンサ取付け(コネクタ名称 B1212)", "取付けの際、原点ポールとの干渉注意", ...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-058", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ヘッド部マグネットスタンド取付治具", "Size": "", "ToolOther": "FM-2898", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整①[OP]", "WorkItems": [], "WorkPoints": [ "自動ピン交換仕様時作業", "コンベアレールのガイドに取付", "熱補正ポールに当付け", "自動ピン交換仕様時作業", "コンベアレールのガイドに取付", "熱補正ポールに当付け" ], "Tolks": ...
{ "QualityItem": "設置確認", "ToolManageNo": "FM-2898", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示箇所に設置出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "自動ピン交換仕様", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "てこ式ダイヤルゲージ", "Size": "1/100", "ToolOther": "", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整①[OP]", "WorkItems": [], "WorkPoints": [ "自動ピン交換仕様時作業", "コンベアレールのガイドに取付", "熱補正ポールに当付け", "自動ピン交換仕様時作業", "コンベアレールのガイドに取付", "熱補正ポールに当付け", "自動ピン交換仕様時作業", ...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "1回/半年", "ToolRecord": "校正成績書", "StdVal": "レール上面との段差:±0.25㎜", "Method": "てこ式ダイヤルゲージ", "RecordMethod": "WEBS-F013-103", "Other": "自動ピン交換仕様", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ノズルチェンジャー位置決め治具", "Size": "", "ToolOther": "FM-3333", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整①[OP]", "WorkItems": [], "WorkPoints": [ "自動ピン交換仕様時作業", "コンベアレールのガイドに取付", "熱補正ポールに当付け" ], "Tolks": [ "締付トルク 95cN・m", "締付トルク 95cN・m" ], "InspectionNo": ""...
{ "QualityItem": "取付確認", "ToolManageNo": "FM-3333", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "自動ピン交換仕様", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ノズルチェンジャー位置決め治具", "Size": "", "ToolOther": "FM-4707", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整①[OP]", "WorkItems": [], "WorkPoints": [ "自動ピン交換仕様時作業", "コンベアレールのガイドに取付", "熱補正ポールに当付け" ], "Tolks": [ "締付トルク 95cN・m", "締付トルク 95cN・m" ], "InspectionNo": ""...
{ "QualityItem": "取付確認", "ToolManageNo": "FM-4707", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "260㎜対応", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "2.5㎜", "ToolOther": "95cN・m", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整①[OP]", "WorkItems": [], "WorkPoints": [ "自動ピン交換仕様時作業", "コンベアレールのガイドに取付", "熱補正ポールに当付け", "自動ピン交換仕様時作業", "コンベアレールのガイドに取付", "熱補正ポールに当付け" ], "Tolks": [ ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "95cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ヘッド部マグネットスタンド取付治具", "Size": "", "ToolOther": "FM-2898", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整②[OP]", "WorkItems": [ "1. 取付平面度調整", "2. 取付位置調整" ], "WorkPoints": [ "平面度が変わっていないかもう一度確認する事", "①~④のポイントで平面度測定規格値:0.05㎜以内", "取付位置確認規格値:A=16.5±0.2㎜ B=11±1.0㎜(260...
{ "QualityItem": "設置確認", "ToolManageNo": "FM-2898", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示箇所に設置出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "自動ピン交換仕様", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "てこ式ダイヤルゲージ", "Size": "1/100", "ToolOther": "", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整②[OP]", "WorkItems": [ "1. 取付平面度調整", "2. 取付位置調整" ], "WorkPoints": [ "①~④のポイントで平面度測定規格値:0.05㎜以内", "平面度が変わっていないかもう一度確認する事", "取付位置確認規格値:A=16.5±0.2㎜ B=11±1.0㎜(260㎜仕様時:68±1...
{ "QualityItem": "平面度確認", "ToolManageNo": "-", "ToolCycle": "1回/半年", "ToolRecord": "校正成績書", "StdVal": "平面度:0.05㎜以内", "Method": "てこ式ダイヤルゲージ", "RecordMethod": "WEBS-F013-103", "Other": "自動ピン交換仕様", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ノズルチェンジャー位置決め治具", "Size": "", "ToolOther": "FM-3333", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整②[OP]", "WorkItems": [ "2. 取付位置調整" ], "WorkPoints": [ "平面度が変わっていないかもう一度確認する事", "取付位置確認規格値:A=16.5±0.2㎜ B=11±1.0㎜(260㎜仕様時:68±1.0㎜)", "上面のネジで調整", "自動ピン交換仕様時作業" ...
{ "QualityItem": "取付確認", "ToolManageNo": "FM-3333", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "自動ピン交換仕様", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ノズルチェンジャー位置決め治具", "Size": "", "ToolOther": "FM-4707", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整②[OP]", "WorkItems": [ "2. 取付位置調整" ], "WorkPoints": [ "平面度が変わっていないかもう一度確認する事", "取付位置確認規格値:A=16.5±0.2㎜ B=11±1.0㎜(260㎜仕様時:68±1.0㎜)", "上面のネジで調整", "自動ピン交換仕様時作業" ...
{ "QualityItem": "取付確認", "ToolManageNo": "FM-4707", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "260㎜対応", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "", "ToolOther": "", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整②[OP]", "WorkItems": [ "1. 取付平面度調整", "2. 取付位置調整" ], "WorkPoints": [ "平面度が変わっていないかもう一度確認する事", "①~④のポイントで平面度測定規格値:0.05㎜以内", "取付位置確認規格値:A=16.5±0.2㎜ B=11±1.0㎜(260㎜仕様時:68±1.0㎜)", ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "95cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "", "ToolOther": "", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整②[OP]", "WorkItems": [ "1. 取付平面度調整", "2. 取付位置調整" ], "WorkPoints": [ "平面度が変わっていないかもう一度確認する事", "①~④のポイントで平面度測定規格値:0.05㎜以内", "取付位置確認規格値:A=16.5±0.2㎜ B=11±1.0㎜(260㎜仕様時:68±1.0㎜)", ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "1.5N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ノギス", "Size": "150㎜", "ToolOther": "", "WorkName": "自動ピン交換用ノズルチェンジャー取付調整②[OP]", "WorkItems": [ "2. 取付位置調整" ], "WorkPoints": [ "平面度が変わっていないかもう一度確認する事", "取付位置確認規格値:A=16.5±0.2㎜ B=11±1.0㎜(260㎜仕様時:68±1.0㎜)", "上面のネジで調整", "自動ピン交換仕様時作業" ], "Tolks": [...
{ "QualityItem": "隙間確認", "ToolManageNo": "-", "ToolCycle": "1回/年", "ToolRecord": "校正成績書", "StdVal": "隙間:16.5±0.2㎜11±1.0㎜", "Method": "ノギス", "RecordMethod": "WEBS-F013-103", "Other": "自動ピン交換仕様", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ノズルチェンジャーポール取付(F)", "WorkItems": [ "1. 架台に①を取付." ], "WorkPoints": [], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "現在の作業位置", "後側", "前側" ] }
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "3㎜", "ToolOther": "3.2N・m", "WorkName": "ノズルチェンジャーコネクタブラケット取付(F)", "WorkItems": [ "1. ブラケットに架台下からのノズルチェンジャー用配線のコネクタを挿入する", "2. ブラケットにノズルチェンジヤー用配線と配管をインシュロックにて結束", "3. BRACKET を架台にBOLT WASHER で取付" ], "WorkPoints": [ "前側用のBRACKET を取付けること コ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.2N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ヘッド部マグネットスタンド取付治具", "Size": "", "ToolOther": "FM-2898", "WorkName": "ノズルチェンジャー駆動部取付・調整(F)①", "WorkItems": [ "1. ノズルチェンジャーポールに①をBOLT にて仮取付", "2. XY軸を測定位置へ移動させる", "3. ヘッドプレートに㉘を取付け" ], "WorkPoints": [ "X軸:ヘットカメラの中心とヘットオプション駆動ユニットの中心を合わせる" ], "Tolks": ...
{ "QualityItem": "設置確認", "ToolManageNo": "FM-2898", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示箇所に設置出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ヘッドオプション駆動部位置決め治具", "Size": "", "ToolOther": "FM-3700", "WorkName": "ノズルチェンジャー駆動部取付・調整(F)①", "WorkItems": [], "WorkPoints": [ "治具を入れ平行調整支点にする", "Y軸:Y軸LMガイドレール取付け穴の3番目に合わせる", "SD-EJM1EH1-021にて締結" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], ...
{ "QualityItem": "設置確認", "ToolManageNo": "FM-3700", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示箇所に設置出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "8㎜", "ToolOther": "40N・m", "WorkName": "ノズルチェンジャー駆動部取付・調整(F)②", "WorkItems": [], "WorkPoints": [ "平行調整後、治具を取外し、固定用ボルトを取付", "規格値:0.03㎜以下" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "検査表①:ヘッドオプション駆動ユニット取付" ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "40N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "ヘッド部マグネットスタンド取付治具", "Size": "", "ToolOther": "FM-2898", "WorkName": "ノズルチェンジャー駆動部取付・調整(F)②", "WorkItems": [ "1. ㉙に㉚を取付後、測定位置に当てる", "2. ダイヤルゲージの目盛を『0』に設定", "3. X軸を移動させて規格値内になる様にヘッドオプション駆動ユニットを平行調整", "4. ヘッドプレートから㉙㉚を外す", "2. ダイヤルゲージの目盛を『0』に設定", "3. ...
{ "QualityItem": "設置確認", "ToolManageNo": "FM-2898", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示箇所に設置出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "てこ式ダイヤルゲージ", "Size": "1/100", "ToolOther": "", "WorkName": "ノズルチェンジャー駆動部取付・調整(F)②", "WorkItems": [ "1. ㉙に㉚を取付後、測定位置に当てる", "2. ダイヤルゲージの目盛を『0』に設定", "3. X軸を移動させて規格値内になる様にヘッドオプション駆動ユニットを平行調整", "4. ヘッドプレートから㉙㉚を外す", "2. ダイヤルゲージの目盛を『0』に設定", "3. X軸を移動させて規...
{ "QualityItem": "平行度確認", "ToolManageNo": "-", "ToolCycle": "1回/半年", "ToolRecord": "校正成績書", "StdVal": "平行度:0.03㎜以下", "Method": "てこ式ダイヤルゲージ", "RecordMethod": "WEBS-F013-101", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ノズルチェンジャー取付(F)", "WorkItems": [ "1. ヘッドオプション駆動ユニット①②を仕様に合わせて取付" ], "WorkPoints": [ "マシンの仕様を確認後、取付の事", "ヘッドオプション駆動ユニットにガタ無い事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ノズルチェンジャー接続1(F)", "WorkItems": [ "1. ブラケットに架台下からのノズルチェンジャー用配線のコネクタを挿入する", "2. バルブに架台下からのノズルチェンジャー用配管を挿入する", "3. ブラケットにノズルチェンジヤー用配線・配管をインシュロックにて結束" ], "WorkPoints": [ "配管の折れ曲りに注意すること", "配線は収縮チューブ周辺で縛り付...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-101", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "ノズルチェンジャー接続2(F)", "WorkItems": [ "1. バルブにノズルチェンジャー用配線を接続しポストにインシュロックにて結束", "2. ブラケットにノズルチェンジャー用配線を接続しポストにインシュロックにて結束" ], "WorkPoints": [ "配線に負荷がかからないように注意すること", "コネクタ名称:R01", "配線に負荷がかからないように注意すること", ...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-058", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "No.2", "ToolOther": "180cN・m", "WorkName": "マルチ認識カメラ接続(F)", "WorkItems": [], "WorkPoints": [ "トレイ仕様 M6ボルト 4本", "17連交換台車仕様 M6ボルト 2本", "切替仕様 M6ボルト 4本" ], "Tolks": [ "締付トルク: 180cN・m" ], "InspectionNo": "", "InspectionItems": [], ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "180cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "認識カメラ浮かせ治具", "Size": "", "ToolOther": "FM-4041", "WorkName": "マルチ認識カメラ接続(F)", "WorkItems": [], "WorkPoints": [ "トレイ仕様 M6ボルト 4本", "17連交換台車仕様 M6ボルト 2本", "切替仕様 M6ボルト 4本" ], "Tolks": [ "締付トルク: 180cN・m" ], "InspectionNo": "", "InspectionItems": [], "W...
{ "QualityItem": "設置確認", "ToolManageNo": "FM-4041", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示箇所に設置出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マルチ認識カメラ接続(F)", "WorkItems": [ "1. ドロアコネクタを取外す", "2. CAMERAケーブルをマルチ認識カメラに接続し、⑥をSCREW で締結" ], "WorkPoints": [ "架台に㉛治具を置き、治具の上にマルチカメラをセットし配線する", "接続完了後、㉛治具を取外す事", "ドロアを固定しているボルトを取外す", "トレイ仕様 M6ボルト 4本", ...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-058", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "5㎜", "ToolOther": "9.8N・m", "WorkName": "マルチ認識カメラ取付(F)", "WorkItems": [ "■1. 架台に①をBOLT WASHER で取付", "2. マルチ認識カメラに保護カバーを取付" ], "WorkPoints": [ "架台取付け面にアルカンサス砥石を軽くかけバリ等無い事確認する", "カメラタイプを確認し取付ける事" ], "Tolks": [], "InspectionNo": "", "...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "9.8N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "保護カバー", "Size": "", "ToolOther": "FM-3999", "WorkName": "マルチ認識カメラ取付(F)", "WorkItems": [ "■3. 検査書に①のシリアルNo.を記入する" ], "WorkPoints": [ "架台部ピンに①を挿入する", "ピンに挿入する" ], "Tolks": [ "・締付トルク 9.8N・m" ], "InspectionNo": "", "InspectionItems": [], "Words": ...
{ "QualityItem": "取付確認", "ToolManageNo": "FM-3999", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "マルチ認識カメラ取付(F)", "WorkItems": [ "■1. 架台に①をBOLT WASHER で取付", "2. マルチ認識カメラに保護カバーを取付", "■3. 検査書に①のシリアルNo.を記入する" ], "WorkPoints": [ "架台取付け面にアルカンサス砥石を軽くかけバリ等無い事確認する", "カメラタイプを確認し取付ける事", "架台部ピンに①を挿入する", "ピ...
{ "QualityItem": "製造番号記録", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "製造番号転記", "Method": "目視", "RecordMethod": "WEBS-F013-101", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前側ロードセル本体取付(装着荷重)", "WorkItems": [ "1. にSPACER を挿入し架台に取付", "2. ロードセル取付ブロック位置だし", "3. ロードセルのコネクタ接続" ], "WorkPoints": [ "キャップを外して を取付", "SPACER を挿入しスパナで締結", "傾きなく、コンベアレールと平行にになるよう取付", "台座固定ボルトを緩める...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-103", "Other": "装着荷重測定ユニットオプション", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "3㎜", "ToolOther": "3.2N・m", "WorkName": "前側ロードセル本体取付(装着荷重)", "WorkItems": [ "1. にSPACER を挿入し架台に取付", "2. ロードセル取付ブロック位置だし" ], "WorkPoints": [ "傾きなく、コンベアレールと平行にになるよう取付", "台座固定ボルトを緩める", " のロードセル部を外す" ], "Tolks": [], "InspectionNo...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.2N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "2.5㎜", "ToolOther": "150cN・m", "WorkName": "前側ロードセル本体取付(装着荷重)", "WorkItems": [ "1. にSPACER を挿入し架台に取付", "2. ロードセル取付ブロック位置だし" ], "WorkPoints": [ "傾きなく、コンベアレールと平行にになるよう取付", "台座固定ボルトを緩める", " のロードセル部を外す" ], "Tolks": [], "Inspe...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "150cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前面本体配線接続①(装着荷重)", "WorkItems": [ "1. ロードセルの配線を引き回し固定する" ], "WorkPoints": [ "配線・配管束の後ろへ引き回す", "ケーブルはグロメットに通す", "ケーブルが屈折により負荷がかからないように注意する事" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "...
{ "QualityItem": "引き回確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り引き回が出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "装着荷重測定ユニットオプション", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "前面本体配線接続②(装着荷重)", "WorkItems": [ "1. ロードセルの配線を引き回し接続" ], "WorkPoints": [ "リアからの配線を前面へ引き回す", "上からの配線", "CPU背面からの配線" ], "Tolks": [], "InspectionNo": "", "InspectionItems": [], "Words": [ "B2005R", ...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-103", "Other": "装着荷重測定ユニットオプション", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "5㎜", "ToolOther": "9.8N・m", "WorkName": "やぐらユニット取付(F)", "WorkItems": [ "1. ①をBOLT WASHER で取付" ], "WorkPoints": [ "やぐら右手前はY方向のみPIN当て", "やぐら右奥部はピンなし", "左側(基準側)を締結後、締結作業を実施する事" ], "Tolks": [ "締付トルク 9.8N・m" ], "InspectionNo": "", ...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "9.8N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "トルクドライバー", "Size": "T-20", "ToolOther": "60cN・m", "WorkName": "やぐらユニット取付(F)", "WorkItems": [ "■2. ヒンジ安全SWをやぐらにBOLT WASHER で取付" ], "WorkPoints": [], "Tolks": [ "締付トルク 60cN・m" ], "InspectionNo": "", "InspectionItems": [], "Words": [ "フロント側", "フロント側...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "60cN・m±10%", "Method": "トルクドライバー", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "やぐらユニット取付(F)", "WorkItems": [ "1. ①をBOLT WASHER で取付", "■2. ヒンジ安全SWをやぐらにBOLT WASHER で取付" ], "WorkPoints": [ "やぐら右手前はY方向のみPIN当て", "やぐら右奥部はピンなし", "左側(基準側)を締結後、締結作業を実施する事" ], "Tolks": [ "締付トルク 9.8N・m", ...
{ "QualityItem": "取付確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "安全工程" }
information_extraction
0
null
{ "ToolName": "開閉カバー高さ出し治具", "Size": "", "ToolOther": "FM-3337", "WorkName": "開閉カバー仮付", "WorkItems": [], "WorkPoints": [ "ヒンジ部がダンパーの力で曲がる恐れがあるため、ヒンジ部は長穴の中心で取付", "SD-EJM1EH1-095にて締結", "Y軸固定子を保護して作業を行うこと" ], "Tolks": [ "締付トルク 3.2N・m" ], "InspectionNo": "", "Inspe...
{ "QualityItem": "取付確認", "ToolManageNo": "FM-3337", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り取付出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "トルクレンチ", "Size": "3㎜", "ToolOther": "3.2N・m", "WorkName": "開閉カバー仮付", "WorkItems": [], "WorkPoints": [ "ヒンジ部がダンパーの力で曲がる恐れがあるため、ヒンジ部は長穴の中心で取付", "SD-EJM1EH1-095にて締結", "Y軸固定子を保護して作業を行うこと" ], "Tolks": [ "締付トルク 3.2N・m" ], "InspectionNo": "", "Inspection...
{ "QualityItem": "締付トルク", "ToolManageNo": "-", "ToolCycle": "日常点検(1回/日)", "ToolRecord": "トルクチェック台帳", "StdVal": "3.2N・m±10%", "Method": "トルクレンチ", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "スケール", "Size": "150㎜", "ToolOther": "", "WorkName": "やぐらユニット配線(F)", "WorkItems": [ "1. スイッチにヒンジ安全SW配線を接続し、タイマウントに配線をインシュロックにて固定" ], "WorkPoints": [ "コネクタ名称:S303R", "ピンの破損、抜け等の確認をすること", "コネクタ名称:B2001P/1S104P/G103P", "配線に負荷がかからないように注意すること", "Y軸固定子を保護して作業...
{ "QualityItem": "寸法確認", "ToolManageNo": "-", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "作業指示の寸法である事", "Method": "スケール", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "-", "Size": "", "ToolOther": "", "WorkName": "やぐらユニット配線(F)", "WorkItems": [ "1. スイッチにヒンジ安全SW配線を接続し、タイマウントに配線をインシュロックにて固定" ], "WorkPoints": [ "コネクタ名称:S303R", "ピンの破損、抜け等の確認をすること", "コネクタ名称:B2001P/1S104P/G103P", "配線に負荷がかからないように注意すること", "Y軸固定子を保護して作業を行うこと" ...
{ "QualityItem": "接続確認", "ToolManageNo": "-", "ToolCycle": "-", "ToolRecord": "-", "StdVal": "指示通り接続出来ている事", "Method": "目視", "RecordMethod": "WEBS-F013-058", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "カバー位置出し治具", "Size": "", "ToolOther": "FM-3139", "WorkName": "右側面中央上部カバー取付", "WorkItems": [ "1. 架台にカバー位置出し治具を取付け、①をSCREW で仮固定", "2. 手前側に19㎜、奥側に7㎜の高さ合わせ治具を挿入", "3. 内側からBOLT WASHER で固定" ], "WorkPoints": [ "締付順序 外側 SCREW 5ケ⇒内側カバー側面 BOLT WASHER 1ケ⇒内側カバー上部 BOLT WAS...
{ "QualityItem": "設置確認", "ToolManageNo": "FM-3139", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "指示通り設置出来ている事", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null
{ "ToolName": "カバー高さ合わせ治具", "Size": "19㎜", "ToolOther": "FM-3120", "WorkName": "右側面中央上部カバー取付", "WorkItems": [ "1. 架台にカバー位置出し治具を取付け、①をSCREW で仮固定", "2. 手前側に19㎜、奥側に7㎜の高さ合わせ治具を挿入", "3. 内側からBOLT WASHER で固定" ], "WorkPoints": [ "締付順序 外側 SCREW 5ケ⇒内側カバー側面 BOLT WASHER 1ケ⇒内側カバー上部 BOLT...
{ "QualityItem": "取付確認", "ToolManageNo": "FM-3120", "ToolCycle": "校正対象外", "ToolRecord": "-", "StdVal": "隙間:19㎜", "Method": "目視", "RecordMethod": "-", "Other": "-", "ProcessName": "-" }
information_extraction
0
null