db35cbd7349c-1
screen shows the breakpoint intercept at label RETURN_TO_OPSYS: CAMRPLI ---------- CA InterTest Batch UNCOND BEFORE Intercept --------------- COMMAND ===> SCROLL ===> CUR TRACE=> 000058 000142 000235 000234 000233 000239 000237 000232 000231 000239 0 U---> ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5e4ccc7f774c-0
InterTest™ and SymDump ® 11.0 5688-235 IBM PL/I for MVS & VM CAMRPLI: PROC OPTIONS (MAIN); STMT LEV NT CALL ISPLINK ( DSPLY, PLIDP...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5e4ccc7f774c-1
U---> 58 1 0 RETURN_TO_OPSYS: . . . . . . . . . . . . . . . . . . . . . . . . . . SYSVIEW 11.5 CA11 ----------------- Output ----------------- 05/02/14 18:01:17 Command ====> Scroll *===> C...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
4934460053b0-0
InterTest™ and SymDump ® 11.0 000047 0001 |* 000048 0001 |* 000049 0001 |* 000050 ---- | ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
4934460053b0-1
000234 0017 |* 000235 0001 |* 000236 ---- | 000237 0034 |* ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
41cece0e57de-0
InterTest™ and SymDump ® 11.0 CAMRPLI ---------- CA InterTest Batch UNCOND BEFORE Intercept --------------- COMMAND ===> SCROLL ===> CUR TRACE=> 000058 000142 000235 000234 000233 000239 000237 000232 000231 000239 0 RETURN ( I + 1 );...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
41cece0e57de-1
changes, or wait until you complete the review of the histogram report. Now return to the current statement in the CAMRPLI program. Follow these steps: 1.Type the CS command and press Enter. The application displays the Program Exit Intercept panel. 2.To continue the advanced demo, enter the command go options and pres...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
098aa02ab589-0
InterTest™ and SymDump ® 11.0 InterTest for CICS Quick Reference for All Users 636
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
b4ff9b57879b-0
InterTest™ and SymDump ® 11.0 Using Use InterTest and SymDump for debugging capabilities and fault management InterTest Use the InterTest debugging capabilities to quickly and easily identify and correct errors in: •Batch and IBM ® CICS ® COBOL •Assembler and PL/I programs •IBM IMS/DC applications •IBM DB2 stored proce...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
b4ff9b57879b-1
database information for abending IMS, DB2, and IDMS/DB applications. SymDump Batch is automatically available to every user once installed. Command Syntax The following notation conventions are used throughout the documentation to illustrate application commands: •Uppercase letters and special characters are display...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8cbb57d6bf86-0
InterTest™ and SymDump ® 11.0 Batch Debugging This section describes how to use InterTest Batch to test a program using application batch commands and panels. The application is supported with HELP panels and an online tutorial which describe the application options and commands. You can use this product to test the fo...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8cbb57d6bf86-1
with these environments need little or no training to use this product. During a test session using the ISPF dialog manager, programmers can use the following features to test efficiently: •Split the screen to access other ISPF options, such as EDIT. •Print to the ISPF listing data set. •Enter ISPF or TSO commands from...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
883472068f2a-0
InterTest™ and SymDump ® 11.0 As a result, the breakpoint intercept might not occur, or the wrong sequence of statements appears to be executed while single-stepping. Also, the debugger might appear to highlight the wrong statement at a breakpoint intercept. These unexpected displays do not indicate that a program is b...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
883472068f2a-1
Assembler Offsets Use the statement number in an Assembler program to set breakpoints, as in COBOL programs, or by using the offset. When using an offset, you must prefix the offset with the + sign. For example, enter AT +78 in the Command area of the Intercept panel to set a breakpoint at offset 78. You can also enter...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
e0aa1a98bae2-0
InterTest™ and SymDump ® 11.0 •Current line number (in BROWSE) •Notice of successful completion of a processing function •Notice of an error condition (accompanied by an audible alarm, if one is installed on the terminal) •A frequency count in response to an Info line command Line two, the prompt or input area, is used...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
e0aa1a98bae2-1
Primary Option Menu The following list shows the features available from the Primary Option Menu. Availability of individual options depends on whether you are using ISPF or Roscoe . Option 1 Foreground Use this option to set up and control a test execution of a program. Option 2 Core Use this option to display virtual...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
e73b61676b7b-0
InterTest™ and SymDump ® 11.0 Option 5 Batch Use this option to set up and test a program to be executed in Batch. Option K Keys Use this option to set up and control a test execution of a program. Option K Keys Roscoe users can set their PF keys for InterTest Batch. Type over the default assignments on the PF Key Def...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
b1292e68a827-0
InterTest™ and SymDump ® 11.0 ISPF-HelpHelp Display the Tutorial Table of Contents from the Primary Option Menu. The tutorial summarizes the features and commands. You can page through the tutorial or select a subject from the Tutorial Table of Contents. The Primary Option Menu for Roscoe users is displayed when you s...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
b1292e68a827-1
When Condition Display This panel displays the when conditions set by the line mode COND command, or by the When Control panel. Equate This panel allows data items to be equated to symbolic names. You can then refer to the variable using the data item or the symbolic name. Equate Display This panel displays the equate ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
e14a73758af2-0
InterTest™ and SymDump ® 11.0 Records Display This panel shows a formatted display of the records that are defined under the FILE SECTION in COBOL format. This display is only available for COBOL programs. File Status Panel This panel shows the allocation for each FILE DESCRIPTION by ddname and dsname, and the DCB info...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
e14a73758af2-1
PARM Specifies and overrides the execution parameter to pass to the main program. NOTE PARM is mutually exclusive with the Number of Linkage Parameters field. Number of Linkage Parameters Specifies the number of linkage parameters expected by the main program when there is more than one. (For a COBOL program, this numb...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5ae49264eaf6-0
InterTest™ and SymDump ® 11.0 NOTE For customers with multiple Endevor C1DEFLTS: If you want to use the dynamic symbolic support feature and you have chosen to run the debugging session as if you have a single C1DEFLTS (for example, if you have not defined your Endevor site IDs in IN25SITE table), define the fully qu...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5ae49264eaf6-1
PROTSYM file in this section. Dynamic Symbolic Support Dynamic symbolic support dynamically retrieves the compiler or assembler listing of the monitored program from a listing data set managed by Endevor and loads the listing into the designated PROTSYM file. For this feature to work, the load module library where the...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
9487edefbdbd-0
InterTest™ and SymDump ® 11.0 Dynamic Symbolic Support Return Codes Dynamic symbolic support provides an integrated service using API calls that deploy various proven components including The following: •Endevor •PROTSYM post processors •z/OS dynamic allocation •CSVQUERY •Binder services The following table provides a ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
9487edefbdbd-1
Endevor 32 15 Endevor encountered critical error and cannot continue. NDSB 4 0 Compressed footprint in IDRU invalid. NIDR 2 0 GETMAIN failed. NIDR 32 0 IN25NDSB load failed. NSRV 8 NSRV Listing server ABORTed or failed. 645
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
d20a63a8f1c3-0
InterTest™ and SymDump ® 11.0 0000 12 0000 Incorrect C1DEFLTS used. Intercept Panel The Intercept panel is the point where execution of the test program is controlled. The Intercept panel has the following attributes: •The monitor name of the program that is intercepted is displayed in the upper left corner of the pane...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
d20a63a8f1c3-1
This intercept is displayed upon entry into the first program that you have asked to monitor. To have the application stop upon entry to all programs, enter AT ALL ENTRY on the command line at this intercept. UNCOND BEFORE and UNCOND AFTER INTERCEPT This intercept is displayed when the program reaches an executable sta...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
f0268cc27f6b-0
InterTest™ and SymDump ® 11.0 The STEP command specifies the number of statements to be executed each time the GO command is issued. The STEP COUNT Intercept panel is displayed after each execution. NEXT BEFORE and NEXT AFTER INTERCEPT This intercept is displayed when the next count (set by the NEXT command) is exceede...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
f0268cc27f6b-1
This article describes the breakpoint panels that are accessed from Option 1 on the main menu. When you use a conditional or unconditional breakpoint command, but do not specify operands, the application displays a series of panels to collect the information that is required to define the breakpoint. NOTE You can also ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
ab4af2e6bf92-0
InterTest™ and SymDump ® 11.0 Use the AFTER field to indicate whether to stop the execution before this statement is executed (N), or after the statement is executed (Y). R Deletes a breakpoint. You must enter the statement number. To delete a breakpoint for another program, enter the program name. L Displays the Break...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
ab4af2e6bf92-1
EXEC Shows the number of times the breakpoint has been executed. B/A/T Indicates whether execution stops before the statement (B), after the statement (A), or at a temporary breakpoint (T). Note: If there is a temporary breakpoint, the execution stops before the statement. COMMANDS TO BE EXECUTED Application commands ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
4012ea68b162-0
InterTest™ and SymDump ® 11.0 You can use all SCROLL keys and SCROLL variables in this display. When (or COND) Panel Use the When panel to set, reset (delete), or list conditional breakpoints. Access this panel by entering either COND (or WHEN) or OFFWN, without operands, in the Command field of the Intercept panel. Yo...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
4012ea68b162-1
L Displays the When Conditions Display panel. This panel lists all conditional breakpoints in the program. Field Descriptions WHEN NAME A 1-8 character name that is assigned to the test or program statement number. DATA-AREA-1 The data-name to be tested. OPERATOR Condition which DATA-AREA-1 and DATA-AREA-2 must meet fo...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
c7c7932af773-0
InterTest™ and SymDump ® 11.0 Execute commands at a conditional breakpoint by entering the commands (separated by semicolons) in the COMMANDS TO BE EXECUTED AT WHEN CONDITION field. At the breakpoint, commands execute sequentially until the program resumes execution through the GO command, or until there is a request f...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
c7c7932af773-1
You can use all SCROLL keys and SCROLL variables in this display. Equate Panel Use the Equate panel to set, drop (delete), or list equated variable names. You can equate a data item with a symbolic name and then refer to by either the symbolic name or the data name. An unlimited number of equates can be set. To access ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5131d52c2716-0
InterTest™ and SymDump ® 11.0 Equate Display Panel The Equate Display panel lists the equate name and actual name for all equates currently set. You can use all SCROLL keys and SCROLL variables in this display. Data Display Panels You view or alter data values in a monitored program using data display panels. Enter one...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
1d34d30e7b70-0
InterTest™ and SymDump ® 11.0 •Alphabetic •AN Alphanumeric •AN-V Varying alphanumeric •ANE Alphanumeric edited •BF Binary floating point •BIT Bit •BIT-V Varying bit •Display (Sterling nonreport) •DE Display edited (Sterling report) •DBC Graphic or DBCS •DBC-V Varying graphic •Floating point (COMP-1/COMP-2) •FD Floating...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
1d34d30e7b70-1
greater than 18 bytes. These fields will be displayed with the message 'TOO BIG TO DISPLAY' in the value. To view or change the actual value of the field, use the CORE command. Alter data by typing over the value field. The application truncates data if you attempt to modify a data item with a value larger than the siz...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5444bd75a9cb-0
InterTest™ and SymDump ® 11.0 For assembler programs, when an access register or 64-bit address is requested for display, an additional line shows the access register or “high half” value, as shown in the following panels: -------------- CA InterTest Batch ASSEMBLER DATA DISPLAY --------------------- COMMAND ===> ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5444bd75a9cb-1
For more information on Assembler indirect addressing, see Control Commands. Invoke the panel by entering the Display command, with or without operands, from an Intercept panel. For assembler and PL/I programs, operands are required. Linkage Panel To invoke the Linkage panel, enter the LInkage command with or without o...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8aa30822f04a-0
InterTest™ and SymDump ® 11.0 COMMAND ===> SCROLL ===> PAGE FD-NAME------------------------DDNAME---DSNAME------------------------------------- INPUT-FILE SYSUT1 INTC.SOME.DATAS OPEN INPUT DSORG=PS RECFM=FB BLK...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8aa30822f04a-1
•Enter the TSO ALLOCATE command on the command line of the current ISPF screen. •Invoke another session and select Option 3 to allocate the file. •Suspend the session and perform the allocation under Roscoe , for Roscoe users. Then resume the ETSO session to resume your InterTest Batch session. NOTE Batch Link users m...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a1c063c12186-0
InterTest™ and SymDump ® 11.0 050400 CAMRCOBB 050200 CAMRCOBB 049800 CAMRCOBB 0200-THESE-ARE-PARAGRAPH-NAMES 049700 CAMRCOBB ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a1c063c12186-1
000947 CAMRCOBB IF P-OPT = '2' 000945 CAMRCOBB IF P-OPT = '1' 000942 CAMRCOBB IF S-AID = 'PF3 ' OR 'PF15' 000939 CAMRCOBB IF RETURN-CODE NOT EQUAL ZERO ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a1c063c12186-2
•Type an address over the primary address field, or an offset from the primary address can be typed over the primary offset field. The primary offset fields are and the display scrolled to that part of memory. 655
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
9b6c0bce849a-0
InterTest™ and SymDump ® 11.0 You can also use the following PF keys: PF10 Restore the address that was previously displayed. PF11 The address indicated by the cursor position appears in the primary address field and the display is scrollable to that part of memory. NOTE If you enter the CORE command from an Intercept ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
9b6c0bce849a-1
Syntax FX string < NEXT|FIRST|LAST|PREV> string Specify a search argument of one to eight hexadecimal characters. 656
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a6814cf92413-0
InterTest™ and SymDump ® 11.0 NEXT Search for the next occurrence of string starting at the beginning of the first address displayed. FIRST Scroll to location zero, and then process the FIND NEXT operation. LAST Start the scan at address X'FFFFFF' (16,777,215) and move backwards to find the last occurrence of string. P...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
3dc0ebaf48fd-0
InterTest™ and SymDump ® 11.0 ID The ID number for each TCB listed Level The hierarchical representation of the TCB Program The program the TCB is assigned to Status The state of the TCB NDISP The format Use the following commands to control what TCB information the Region Map Display panel shows. ID task number Set th...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
f2015819f7f4-0
InterTest™ and SymDump ® 11.0 Control and line commands direct the test session and you enter them only in the Intercept panel. Line commands are shorter versions of some control commands. Report commands generate reports to be printed and analyzed offline. Only enter report commands in the Intercept panel. Display Co...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
f27ea53dec64-0
InterTest™ and SymDump ® 11.0 Specifies the last column of a range of columns to search for string. If col2 is greater than the record length, the record length is used. •NEXT Causes a search for the next occurrence of string starting at the beginning of the first line displayed after the cursor location. The default i...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
12c49132cd7e-0
InterTest™ and SymDump ® 11.0 statement-number Specifies a statement number in the currently qualified program. Cursor Sensitive Find If a data name is displayed and you wish to locate its definition, place the cursor over the data name and press Enter. The application repositions the display at the definition of the ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
12c49132cd7e-1
immediately above the first line of the program listing. The KSIZE command lets you control the maximum depth of the keep window and whether the window should be fixed or variable in size. Syntax Use the following syntax for KSIZE: KSIZE depth F|V 661
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
fe5940873cd1-0
InterTest™ and SymDump ® 11.0 Enter this command in its abbreviated form: KS. Variables Use the following variables with the KSIZE command: depth The maximum number of lines of data to be displayed in the window at one time. F Specify F for a fixed window size. V Specify V for a variable sized window. Usage Notes You c...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
fe5940873cd1-1
KSIZE command. If the window is not scrollable, the KUP command is not functional. If no argument is specified, the default scroll amount is used. The default scroll amount is defined in the upper right corner of the Intercept panel. 662
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8f8f697103aa-0
InterTest™ and SymDump ® 11.0 LOCATE Command Use the LOCATE command to scroll to a specified line or a user-defined symbolic label in the program. Syntax Use the following syntax for LOCATE: LOCATE nnnnnn|.label You can enter this command in its abbreviated form: L. Variables Use the following variables with the LOCATE...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8f8f697103aa-1
other commands that change the display, also cause the specified line commands to be processed. This article describes the following commands: 663
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
39150e1219d0-0
InterTest™ and SymDump ® 11.0 The following table is an overview of the Line commands, the corresponding Control Commands, and their function. The following pages provide a more complete description of each command. Note that some commands have synonyms, such as A and U, which are fully interchangeable. Use whichever o...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
e887b619965a-0
InterTest™ and SymDump ® 11.0 H KEEPX LDIX LDXThe data items on the line where the H is placed are listed at the top of the Intercept panel in a keep window and shown in Hex format. For assembler, the operands for the current instruction in register notation are added to the keep window. Cursor-sensitive KEEPX - if H i...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
e887b619965a-1
I data items on the line are written to the session log for later printing. For assembler, the operands for the current instruction in register notation are written to the session log for later printing. R REMOVE LDIAn RDI, reset data item, is done for each of the data items on the line to remove entries in the keep wi...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
7219f630ce85-0
InterTest™ and SymDump ® 11.0 V COND WHENA variable change breakpoint is set at the specified line. The breakpoint is triggered before the line is executed when the application determines that the value of a variable in the line changes. Cursor-sensitive variable change breakpoint - If you enter V and the cursor is pla...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
7219f630ce85-1
size of the screen. If you press Enter or the scroll keys, it sets the breakpoints. You can type other commands over the U. Reset breakpoints using the OFF, O, X, or blank line commands. The following panel shows "before" breakpoints being set on lines 13100, 13400, and 13736 of the program: CAMRCOB2 ---------- CA Int...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
d27d212f9be4-0
InterTest™ and SymDump ® 11.0 ---> 013200 MOVE MASK1 TO BIN1. ---> 013300 MOVE ZERO TO MASK1. u---> 013400 MOVE MASK1 TO BIN1 013410 BIN...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
d27d212f9be4-1
---> 012900 PERFORM WRITE-LINE. U---> 013100 FORCING-THE-ABEND. ---> 013200 MOVE MASK1 TO BIN1. ---> 013300 MOVE ZERO TO MASK1. U---> 013400 ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
2a8fe44bf11b-0
InterTest™ and SymDump ® 11.0 . CAMRCOB2 000541 0000 0000 B SOURCE LINE: PAY-CALC. . CAMRCOB2 000659 0000 0000 B SOURCE LINE: ORDER-CALC. ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
2a8fe44bf11b-1
0001 001144 PERFORM TOTAL-ORDER THRU TOTAL-ORDER-EX 001145 UNTIL SUB-6 EQUAL 5. U---> 001146 ORDER-CALC-EX. ---> 001147 GO TO OPTIONS. 010...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a236690eb24e-0
InterTest™ and SymDump ® 11.0 You may type multiple D line commands on different lines, but to display the Display panel from each line in succession, press the END (PF3 or PF15) key. If D is specified on four lines, the Display panel appears for the data items on the first line. When END is pressed, the Display panel ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a236690eb24e-1
0001 012300 PROCEDURE DIVISION USING PARMS TEST-THREE TEST-FOUR PASS- 0001 012400 DEMO-BEGIN. ---> 012500 GO TO DEMO-INIT. 0001 012600 DEMO-INIT. ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a236690eb24e-2
during execution. If multiple GT commands are entered, the execution is resumed until the first GT line is reached and other GT commands are treated as temporary breakpoints. 669
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
15a25c6b66c6-0
InterTest™ and SymDump ® 11.0 To reset a temporary breakpoint that was created by a GT command, use the OFF, O, X, or blank line commands. CAMRCOB ---------- CA-InterTest Batch TEMP BP Intercept --------------------- COMMAND ===> SCROLL ===> CUR 0001 000886 ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
15a25c6b66c6-1
000907 ELSE ---> 000908 MOVE 'H' TO R1498-STATUS. ---> 000909 TIME-EDIT-EX. ---> 000910 EXIT. H Command (Display Hex Data) For COBOL or PL/I programs,...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
15a25c6b66c6-2
COMMAND ===> SCROLL===> PAGE TRACE=> 013200 013100 020100 020000 012900 012800 012700 012600 012500 012400 7 CAMRCOB2 15.49.31 JUN 30,2014 0001 012300 PROCEDURE DIVISION USING PARMS TEST-THREE TEST-FOUR PASS- 670
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
51fb9b96c9db-0
InterTest™ and SymDump ® 11.0 0001 012400 DEMO-BEGIN. 0001 012500 GO TO DEMO-INIT. 0001 012600 DEMO-INIT. 0001 012700 OPEN OUTPUT OUTPUT01. 0001 ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
51fb9b96c9db-1
COMMAND ===> SCROLL===> PAGE TRACE=> 013200 013100 020100 020000 012900 012800 012700 012600 012500 012400 ------------------------------------------------------------------------ 00243DA0 AN 004000 03 MASK1 ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
51fb9b96c9db-2
U---> 013400 MOVE MASK1 TO BIN1 For assembler programs, if you use the H line command within the keep window, the high half of the 64bit register is displayed in a short message at the top of the screen. The following panel shows the short message displayed when the H c...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
2500476bcef9-0
InterTest™ and SymDump ® 11.0 MEMTEST ---------- CA InterTest Batch *INITIAL* Inte- High Half = 00000001 COMMAND ===> SCROLL ===> CSR TRACE=> 000060 000059 000058 000056 000055 000050 000049 000048 000047 000046 0 --------------------------------------------...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
2500476bcef9-1
U0001 001141 ORDER-CALC. 0001 001142 MOVE CUSTOMER-VALUES TO CUSTOMER-ORDER. 0001 001143 MOVE ZEROES TO ORDER-SUB-TOTAL, SUB-6, LOOP-O 0001 001144 PERFORM TOTAL-ORDER THRU TOTAL-ORDER-EX ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
2500476bcef9-2
COMMAND ===> SCROLL ===> CSR TRACE=> 000060 000059 000058 000056 000055 000050 000049 000048 000047 000046 0 ------------------------------------------------------------------------- 00000000 HX 000000 02 R1 000000000000000000....
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5418220ea78f-0
InterTest™ and SymDump ® 11.0 commands, see the LDI (or KEEP) command in the Control Commands section that follows. The number of L's you can specify is limited only by the number of data items displayed because of the screen size. Cursor-sensitive keep: If you enter L or K and the cursor is placed on a COBOL or PL/I d...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5418220ea78f-1
0001 012600 DEMO-INIT. 0001 012700 OPEN OUTPUT OUTPUT01. 0001 012800 MOVE HD1 TO LINE-OUT. 0001 012900 PERFORM WRITE-LINE. ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
5418220ea78f-2
00204DBA NB-S 004800 03 BIN3 +00000032. 00204DBE NB-S 004900 03 BIN4 +00000077. ------------------------------------------------------------------------ 7 CAMRCOB2 15.49.31 JUN 30,2014 0001 ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
dab9f370e394-0
InterTest™ and SymDump ® 11.0 0001 012800 MOVE HD1 TO LINE-OUT. 0001 012900 PERFORM WRITE-LINE. U0001 013100 FORCING-THE-ABEND. 0001 013200 MOVE MASK1 TO BIN1. 0001 ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
dab9f370e394-1
7 CAMRCOB2 15.49.31 JUN 30,2014 0001 012300 PROCEDURE DIVISION USING PARMS TEST-THREE TEST-FOUR PASS- 0001 012400 DEMO-BEGIN. 0001 012500 GO TO DEMO-INIT. ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
dab9f370e394-2
7 CAMRCOB2 15.49.31 JUN 30,2014 0001 012300 PROCEDURE DIVISION USING PARMS TEST-THREE TEST-FOUR PASS- 0001 012400 DEMO-BEGIN. 674
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
b76a9d8715b6-0
InterTest™ and SymDump ® 11.0 0001 012500 GO TO DEMO-INIT. 0001 012600 DEMO-INIT. 0001 012700 OPEN OUTPUT OUTPUT01. 0001 012800 MOVE HD1 TO LINE...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
b76a9d8715b6-1
For further description and a sample of the session log, see Session Log Facility (Review Debugging Session) at the end of this section. R Command (Reset Data Item Display) The R line command resets a data item display from an LDI command, an L line command, an LDX command, or an H line command. Place the R line comman...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
b76a9d8715b6-2
NUMERICS 0000 ------------------------------------------------------------------------ 7 CAMRCOB2 15.49.31 JUN 30,2014 0001 012300 PROCEDURE DIVISION USING PARMS TEST-THREE TEST-FOUR PASS- 675
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
734c330ba4c6-0
InterTest™ and SymDump ® 11.0 0001 012400 DEMO-BEGIN. 0001 012500 GO TO DEMO-INIT. 0001 012600 DEMO-INIT. 0001 012700 OPEN OUTPUT OUTP...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
734c330ba4c6-1
0001 012500 GO TO DEMO-INIT. 0001 012600 DEMO-INIT. 0001 012700 OPEN OUTPUT OUTPUT01. 0001 012800 MOVE HD1 TO LINE-OUT. ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a84e0dbdc8cf-0
InterTest™ and SymDump ® 11.0 The last statement in the program •The last statement in a performed paragraph •Immediately followed by an ELSE statement For more details, see the SKIP Command (Skip a Statement). The following panel shows a skip breakpoint being set at statement 21010. The S causes the call to the progra...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
a84e0dbdc8cf-1
021700 BIN3 021800 BIN4. *--> 021900 IF BIN1 = BIN2 022000 NEXT SENTENCE. The f...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8acfffa47b39-0
InterTest™ and SymDump ® 11.0 ---> 021310 DISPLAY MASK1 BIN1 BIN2 BIN3 BIN4. ---> 021400 MOVE ZERO TO MASK1. ---> 021500 MOVE MASK1 TO BIN1 021600 BIN2...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8acfffa47b39-1
U0001 001141 ORDER-CALC. 0001 001142 MOVE CUSTOMER-VALUES TO CUSTOMER-ORDER. 0001 001143 MOVE ZEROES TO ORDER-SUB-TOTAL, SUB-6, LOOP-O 0001 001144 PERFORM TOTAL-ORDER THRU TOTAL-ORDER-EX ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
8acfffa47b39-2
show you where breakpoints have been set. The ) line command is only valid on executable lines of the program listing. Executable lines contain a frequency counter number or arrow. There is no limit other than the size of the screen. If you press Enter or the scroll keys, it sets the breakpoints. You can type other com...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
552b2bda1fd6-0
InterTest™ and SymDump ® 11.0 COMMAND ===> SCROLL===> PAGE TRACE= 012400 012300 7 CAMRCOB2 15.49.31 JUN 30,2014 0001 012300 PROCEDURE DIVISION US...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
552b2bda1fd6-1
column to show you where it is. CAMRCOB2 ---------- CA InterTest Batch NEXT BEFORE Intercept ----------------- COMMAND ===> SCROLL===> PAGE TRACE=> 012400 012300 7 CAMRCOB2 15.49.31 ...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
c12d2332a156-0
InterTest™ and SymDump ® 11.0 You can also use the LISTAT command to show the Breakpoints panel as follows: -------------------- CA InterTest Batch BREAKPOINTS PANEL --------------------- COMMAND ===> SCROLL ===> CUR *************************** Top of Data ******...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
c12d2332a156-1
command is only valid for COBOL or PL/I programs. The following panel shows a data display for WA-T1-3A(BIN1,4,1) of WA-TABLE-1 of WA-LEVEL1. Currently, WA- T1-3A(2,4,1) is displayed. Note the address and the value. The first subscript (BIN1) and the third subscript are incremented by the value of 2. CAMRCOB2 ---------...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
459e3eb8e2f3-0
InterTest™ and SymDump ® 11.0 0001 022100 TABLE-MOVE. 0001 022200 MOVE TABLE-FILL TO WA-TABLE-1 OF WA-LEVEL1. U---> 022300 NUM-EDITED-TEST. ---> 022310 MOVE 'XP' TO ED-A...
/Users/ilidiolopes/Documents/ca-intertest-and-ca-symdump-11-01.pdf
459e3eb8e2f3-1
0001 021500 MOVE MASK1 TO BIN1 021600 BIN2 021700 BIN3 021800 BIN4. ...