id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
7e957e11-df68-4ff1-9faf-9bb46caf6be9
We use Equation 4.1 to compute the theoretical force required to strip the threads of the bolt. FSt¼Su/C2ATS where Su¼96 ksi ATS¼0.891/C2(0.547/0.625) ¼0.780 in.2 FSt¼78,000 /C20.780 ¼60,825 lbs Now we apply the strength reduction factors as follows: SR1¼strength reduction factor for nut dilation for a 1.45:1 ratio ¼0....
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
124
0c4aa8b5-de8b-46eb-8a3d-5205524d909f
FIGURE 4.5 Strength reduction factor for thread bending. The horizontal axis gives the ratio of nut strength to bolt strength. (Modified from Alexander, E.M., Design and strength of screw threads, Transactions of Conference on Metric Mechanical Fasteners co-sponsored by ANSI, ASME, ASTM, and SAE, presented at American ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
124
9ba3c906-656c-4750-8e9d-2eac8c601238
The reduced estimate for the strength of our threads is now: FSt0¼FSt/C2SR1/C2SR2/C2SR3/C2SR4 FSt0¼60,825 /C20.8/C20.975/C20.85/C20.95¼38,311 lbs A significant difference! As we saw, the bolt has an FTenof 29,380 lbs so the bolt would presumably break before these threads stripped, which is desirable. Not much margin f...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
125
8ba767ec-f0f3-4434-9156-86fd8ab44034
4.9.2 W HICHISUSUALLY STRONGER —N UT OR BOLT? We have considered this issue several times, but it is important enough to elaborate. You will find that the proof strength of a standard nut is generally greater than the proof strength ofthe fastener with which it is supposed to be used. Designers would prefer bolt failur...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
125
0c6ad508-1af4-4fb0-aef0-ea8b814b3234
stripping occurred. The increased torque indicates an increase in tension or preload in the bolt, when, in fact, all preload is lost when the thread fails. On the other hand, there’s nochance of misreading the situation when the body of a bolt breaks; that’s obvious. In anapparent contradiction, nuts are made of weaker...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
125
517cbef1-b911-4c30-b893-c4db5f66aeb7
3.1 and 4.1) can be used to achieve this result. Most people will use this procedure, or its equivalent in ANSI =ASME B1.1, only to find the thread length of tapped holes. They won’t design nuts. Note that standard nuts come in several configurations. As far as hex nuts are concerned, a regular hex nut has a thread len...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
125
dffccf69-1708-453e-a201-ebd50e3f25eb
give stress areas and thread-stripping areas. The stripping areas for internal threads are1.3–1.5 times those shown in Table 4.6. Remember, we always want the bolt, not the nut,to fail. As mentioned earlier, a more complete table of tensile stress areas will be found in Appendix E. The thread-stripping areas given abov...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
125
132b972d-3f56-4d25-8757-f7e611bf5ca2
TaperedOut-of-round Drunken FIGURE 4.6 Tapered out-of-round or drunken threads all reduce thread-stripping strength. FIGURE 4.7 If the pitch of the male threads differs significantly from that of the female threads, they may be in contact for only part of the length of engagement. FIGURE 4.8 Incorrect tooth angles can ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
126
d5a4d84d-8f27-4e02-83b7-48b63d5020ad
4.10 OTHER FACTORS AFFECTING STRENGTH So much for the conventional wisdom concerning thread strength. The formulas we’ve looked at were all based on the assumption that the threads would be manufactured within tolerancesspecified by ANSI =ASME B1.1 or equivalent. Recent aerospace and other experience has suggested that...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
127
2f3c1da7-4f3b-4aab-b6e6-a9a385a57d12
4.10.1 P ITCHDIAMETER If thread geometry gets too far away from that defined by the ASME B1.1 standard, theequations of this chapter may no longer work [19]. And small differences in thread dimen- sions, angle, etc. may make a significant difference in thread strength [20]. The pitch diameter of a 0.625–18UNF-3A =3B th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
127
b15ecb76-0bc1-4aec-b94a-68794fb2f688
nut having nominal PD. A similar loss of strength occurs if the pitch diameter of the nut is greater than nominal. If both nut and bolt are wrong—the nut being too large and the bolt too small—the loss of strength can be almost complete. 4.10.2 O THERTHREAD PARAMETERS Pitch diameter is not the only geometrical factor w...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
127
b2aea56d-5532-4123-9690-44d69070ef80
Pitch diameter is not the only geometrical factor we must be concerned about. Anything which reduces the amount of contact between male and female threads will affect their strength. If the bolt or nut is slightly tapered, for example, the threads will be partiallydisengaged at one end of the engagement length. If the ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
127
99413548-2141-4a2e-af2c-275160cb87fa
through 4.8. All of them, again, may cause a significant loss of strength in the threads: but studies are needed to confirm this. It has also been suggested that improper thread profilessuch as those shown in these figures can reduce the resistance of a fastener to shock orvibration and therefore will encourage self-lo...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
127
599f480f-310f-4b92-b91b-6325aab7d695
EXERCISES AND PROBLEMS 1. A thread is defined as1=2–13UNC 3B (21). What does that tell us about the thread? 2. Another thread is defined as M8 /C21.25 6H. What does that tell us? 3. We have a1=4–20 Class 2A thread on an ASTM A325 bolt. How much force would be required to break the bolt? (refer Section 2.5.2, Table 4.4,...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
128
d22c6af8-9071-43c4-88eb-55871a893016
7. We are planning to use a special nut on the bolt described in #3 above. Here are the parameters of the nut: Material: 6061 T6 aluminum Across the flats dimension: 0.4 in. The nut will be lubricated. It will be tightened with a hand wrench.How much force would be required to strip the threads of this nut? (refer Sect...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
128
fc0360b3-835b-4b68-baba-12ba50bf2dbe
2. Unified Inch Screw Threads UN and UNR Thread Forms, ASME Standard B 1.1-1989, ASME, New York, 1989. 3. Screw Thread Standards for Federal Services—Section 2, Unified Inch Screw Threads—UN and UNR Forms, FED-STD-H28 =2B, Federal Supply Services, General Services Administration, Philadelphia, August 20, 1991. 4. Screw...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
128
442d45fe-7f50-435d-a458-9cbc713667f1
Reaffirmed 1992, ASME, New York, 1992. 8. Thread forms and torque systems boost reliability of bolted joints, Product Engineering , December 1977, p. 37. 9. Waltermire, W.G., A fresh look at a basic question: coarse or fine threads? Machine Design , March 17, 1960. 10. Comments made by Richard T. Barrett of NASA Lewis ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
128
1c2a6521-5a3a-4e6c-bcda-b729deb94358
by Sweden-Bultfabrike, AB, 1975. 14. Alexander, E.M., Design and strength of screw threads, Transactions of Conference on Metric Mechanical Fasteners co-sponsored by ANSI, ASME, ASTM, and SAE, Presented at AmericanNational Metric Council Conference, Washington, DC, 1975.Bickford/Introduction to the Design and Behavior ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
128
f135ab00-b4bb-40bd-9e2d-c66ed23a6b56
15. Gill, P., The Static Strength of Screw Threads , G.K.N., U.K. 16. Parisen, J.D., Length of Thread Engagement in Nodular Iron , General Motors Corp., Warren, MI, 1969. 17. Wiegand, H. and K.H. Illgner, Boltbarkeit von Schraebenuer-bindungen mit ISO , Gewindeprofil, Konstruktion, 1967. 18. Blake, A., What Every Engin...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
129
be5a0a98-dda1-44aa-8914-2f9d44e865af
1989. 21. Metric Screw Threads for Commercial Mechanical Fasteners—Boundary Profile Defined, ANSI B1.18M-1982 (Reaffirmed 1987), ASME, New York, 1987. 22. Screw Thread Gaging Systems for Dimensional Acceptability—Inch and Metric Screw Threads (UN, UNR, UNJ, M, and MJ), ANSI =ASME B1.3M-1986, ASME, New York, 1986. 23.Ma...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
129
a2f32ee1-cb13-4072-9e44-de2287b8c7d2
New York, 1998. 27. Shigley, J.E. and C. Mischke, Fastening, Joining and Connecting , reprinted from The Mechanical Designers Workbook , McGraw Hill, NY, 1990. 28. Barron, J., ‘‘Where to Use Heavy Hex Nuts,’’ Newport News Naval Shipyard, March 2006.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
129
647bed34-aff0-4bff-9835-922f297733ed
Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C004 Final Proof page 84 26.7.2007 12:24pm Compositor Name: VAmoudavally
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
130
26b6d123-9b27-4918-a325-a1e049167984
5Stiffness and Strain Considerations As we learned in Chapter 1, both bolt and joint members are, in effect, stiff springs. They deflect under load. They relax when the load is removed. They store potential energy and cancreate an appropriate clamping force—and therefore function as an effective joint—only aslong as th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
131
c0d7cf47-492c-4668-81dc-7e717d34ab08
Let’s look in detail, then, at this concept of stiffness and at the related deflection of or strain in the bolt and joint members. We’ll start with the bolt, then examine the joint, and thentake a brief look at the stiffness ratio. 5.1 BOLT DEFLECTION 5.1.1 B ASICCONCEPTS Let’s apply equal and opposite forces to the en...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
131
3350fc08-1e07-4708-b5dd-4a9af66969d7
DL¼FL EA(5:2) where DL¼change in length (in., mm) A¼cross-sectional area (in.2,m m2) L¼length of the section (in., mm) E¼modulus of elasticity (psi, GPa) F¼applied tensile force (lb, N)Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C005 Final Proof page 85 26.7.2007 6:03pm Compositor Name: BMani...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
131
a07d2945-21f6-42bc-b6b7-db108342c752
Since the various sections are connected in series, they each see the same force, so we can combine Equations 5.1 and 5.2 above and write DLC¼FL1 EA1þL2 EA2þL3 EA3/C18/C19 (5:3) Now, the spring constant of a body is defined as K¼F DL(5:4) where K¼spring constant or stiffness (lb =in., N =mm) DL¼change in length of the ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
132
68fb263a-96ee-4260-8769-f873b1b91c22
stretch or change in length of a group of bodies, we see that 1 KT/C18/C19 ¼L1 EA1þL2 EA2þL3 EA3(5:7)F F 12 3F F FIGURE 5.1 Rod of nonuniform diameter, loaded in tension, and equivalent spring model.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C005 Final Proof page 86 26.7.2007 6:03pm Composit...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
132
88f79e46-db42-4f6e-bd9f-0be9cb0d8a62
Note that the stiffness of either a plain or complex body is very much a function of the ratio between length and cross-sectional area—it’s a function, in other words, of the ‘‘shape’’ of body just as much as it is a function of the material from which the body is made. If we take one piece of alloy steel and make two ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
133
46d4380e-60ca-4a77-8e61-ad73787d5fcb
compute the deflection under load. There is some ambiguity, however, about each of these factors when we’re dealing with bolts. We’ll take a closer look. First, though, note that I included the modulus of elasticity in the list of things we’ll need to know. We have not needed that material property until now. Most engi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
133
ccef5a4c-0be0-4395-8f18-ef127d53f1b1
Tensile loads are not applied to bolts ‘‘from end to end’’; they’re applied between the inner face of the nut and the undersurface of the head. The entire bolt is not loaded, therefore, the way the test rods are. There is zero tensile stress in the free ends, for example. There is, however, some stress in portions of b...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
133
9a4815aa-c552-4ed6-a1c4-3e4bfa427673
We know from Chapter 3 that tensile stress in a bolt is maximum near the inner faces of the head and nut, and that tensile stress is zero at the outboard faces of the nut and head. Assuming that there is a uniform decrease in stress from inboard to outboard faces of thehead, as suggested by Figure 3.4, we can make the ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
134
f3113942-ba0e-4c84-89c2-450f31db3698
E) of the fastener is equal to the length of the body ( LB) plus one-half the thickness of the head ( TH) added to the length of the exposed threads ( LT) plus one-half the thickness of the nut ( TN), as suggested by Figure 5.3 or by LE¼LBþTH=2 ðÞ þ LTþTN=2 ðÞ (5:7a) Compare the actual stress levels sketched in Figure ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
134
dffe5e25-47e8-46ee-a1e2-a7e249cb354c
6psi) Bolt Materials Modulus Ref. ASTM A193 B5 30.9 [13] B7 29.7 [13] B8-Cl 1 28.3 [13]B16 29.7 [13] ASTM A325 29.5 [14] ASTM A354 29.3 [13] ASTM A490 29.3 [13]H-11 30.6 [14]Inconel 600 31.4 [14] Ti 6Al-4V 16.5 [14] Metric SAE J1199 [17] 4.6=4.8=5.8 29.5 8.8=9.8=10.9 29.3 Joint materialsSteels low carbon 29.5 [15] Medi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
134
026cad20-8659-4062-8031-ab8e70882b29
because the bulk of the fastener is stressed at, or near, the levels we have assumed. It is only the surfaces of the fastener that exhibit the maximum deviations from these averages. At least that’s true as far as long, thin bolts are concerned. As the length-to-diameter ratio of the bolt decreases, and the bolt become...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
135
628645ee-5f4c-43c4-9251-445648ef1068
each [2]; or nothing for the head and 0.6 /C2D for the nut [3]. The thickness of a standard heavy hex nut, incidentally, is equal to the nominal diameter, so the correction I have suggested is equal to 0.5 /C2Dfor a heavy hex nut and a little more for a light nut. 5.1.2.2 Cross-Sectional Areas of the Bolt We also have ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
135
64b49538-7a2f-4c0e-87b1-db36f4bc7cf0
DLC¼FPLbe EA BþLse EA S/C18/C19 (5:8) where Lbe¼the effective length of the body (true body length plus one-half the thickness of the head of the bolt) (in., mm) (see Appendix F) Lse¼the effective length of the threads (length of exposed threads plus one-half the thickness of the nut) (in., mm) (see Appendix F) DLC¼com...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
135
ab022e8b-69a2-4df3-8f86-37f5a33ce4cc
E¼the modulus of elasticity (psi, N =mm2) (Table 5.1) FP¼tension in bolt (lb, N) If the fastener has a more complex shape, as shown in Figure 5.4, then additional sections must be computed, but there is otherwise no change in the procedure. The change in length for the fastener shown in Figure 5.4, for example, would b...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
136
2c350dd0-aefc-4745-a864-a0474605074f
5.2.2 E XAMPLE Let’s compute the stiffness and change in length of a3=8–16/C21=2SAE, Grade 8 hex bolt (shown in Figure 5.5) in a joint having a 1 in. grip length ( Lg). We can get the nominal dimensions we’ll need by measuring a sample bolt, or, more safely, by referring to the pertinent specifications, or to the data ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
136
0d3f55bd-fc24-4d49-9eeb-8219d516e21c
(D)¼0.375 in. and nominal shank length ( L)¼1.500 in.L1L2 L3 L4L5L6(5.9) ∆LC = FP +++++L1 EA1L2 EA2L3 EA3L4 EA4L5 EA5L6 EA6 FIGURE 5.4 Each cross section of a complex fastener must be computed separately.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C005 Final Proof page 90 26.7.2007 6:03pm Com...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
136
c2336dae-66e8-4f17-bbdc-1723ca806c65
AB¼pD2 4¼p(0:375)2 4¼0:1104 in:2 We must now compute the nominal cross-sectional area ( AB), the nominal length of the body ( LB), LB¼L/C0Lt¼1:5/C01:0¼0:5in: and the effective lengths of body and threaded sections, remembering that we’re interested only in the threads that are actively engaged in carrying load: Lbe¼LBþ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
137
8169e21b-2dc0-414a-9d5a-5e5c30fd4c0d
Chapter 2.) To convert this desired stress level to axial force, we multiply the stress value by the tensile stress area of the threads: FP¼SY/C2AS¼78,000 /C20:0775¼6045 lbs We can now compute the change in length, which this tensile force would create in this bolt in this joint, DLC¼FP1 KB/C18/C19 ¼6045/C20:4708/C210/...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
137
6ad2cc71-c73f-434d-bef7-103df016605d
5.2.3 A CTUAL VERSUS COMPUTED STRETCH AND STIFFNESS The equations we have given are widely used, but the stretch and stiffness they predict can be quite inaccurate. The exact dimensions of a given bolt won’t be the nominal dimensions inmost cases, because of manufacturing variations. The modulus of elasticity will vary...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
138
77275dc3-b02a-43d0-973d-ba4954a3c282
bolt, however; it’s clamped by a bolt-and-nut system—or by a bolt–nut–washer system. The stiffness of this combination of parts is found by 1 KT¼1 KBþ1 KNþ1 KW(5:11) where KT¼total stiffness of the system (lb =in., N =mm) KB¼stiffness of the bolt (lb =in., N =mm) KN¼stiffness of the nut (lb =in., N =mm) Kw¼stiffness of...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
138
f9eb1f41-9bff-4014-8586-99c562cde88a
None of this is taken into consideration in classical joint design, however, which assumes linear, elastic behavior, and which assumes that the stiffness of the clamping element will be that of the bolt alone. We’ll know better by the time we study Chapter 11. Before leaving the subject of washers we should note that t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
138
1dd43de8-db8f-43fb-919c-4660d83751fc
the design and behavior of the bolted joint. 5.2.5 A LTERNATIVE EXPRESSION FOR BOLTSTIFFNESS Although the procedure we’ve used to compute bolt stiffness is correct and emphasizes the all- important deflection or change in length of the bolt, it’s cumbersome. If we’re interested in the stiffness of a conventional bolt w...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
138
bbe385d9-39af-4698-aeae-3e2c392e41b5
Hooke’s law E¼(FP=AS)=(/C1L=Le) Rewriting it, FP¼EA sDL L Substituting this expression for Fpin Equation 5.10 gives us KB¼EA s Le(5:12) where E¼modulus of elasticity of the bolt (psi, GPa) AS¼tensile stress area of the bolt (in.2,m m2) Le¼effective length of the bolt (in., mm) This equation assumes that the stiffness o...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
139
12817203-7fbb-4fcf-b49a-c8f109e43ee3
complicated than Equation 5.12, it’s still easy to use and gives us a far more accurate estimate ofK Bthan does the more common Equation 5.12. 5.2.6 E NERGY STORED IN THE BOLT Lest we forget!—we’re interested in the bolt as an energy storage device. It can create that all- important clamping force on the joint only as ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
139
277240d8-86c5-4e70-adc0-6864a2ce97b5
PE B¼DL/C2FB=2 (5:13) where FB¼tension in the bolt (lb, N) DL¼deflection in the bolt (in., mm) PEB¼the potential energy stored in the bolt (in.-lb, mm-N) Note that if we were to plot the tension in the bolt versus its deflection as we tightened the nut,we’d generate a curve like that shown in Figure 5.6: a straight lin...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
139
960e47db-2ba1-4193-95d0-5d476b7426fe
Equation 5.13 is good only for the straight-line portion of the curve; it defines the area under that curve. We’d have to use graphical techniques, calculus, or a computer to estimate the energy stored in a bolt that had deformed plastically—but this would still be equal to the area under the FB–ALcurve. 5.3 THE JOINT ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
140
ba7e78a6-ece4-41c2-9efc-33ffc5591bdc
line as long as the bolt deforms elastically. When it yields, the line becomes a curve as shown. The energy stored in the bolt is equal to the area under the curve. FFT1 T2KJ = F ∆TJ 1 K+1 K1=1 K2+T2 EA1T2 EA2=where(5.15) (5.16) FIGURE 5.7 Two blocks in compression.Bickford/Introduction to the Design and Behavior of B...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
140
43ceac8e-8909-4257-8fcc-406f811c2293
DTJ¼DT1þDT2¼FT1 EA1þT2 EA2/C18/C19 (5:14) and KJ¼F DTJ(5:15) where 1 K¼1 K1þ1 K2¼T2 EA1þT2 EA2(5:16) Theoretically, the relationship between applied compressive force and deflection for our pair of blocks should be linear as long as the force stays within the elastic limit of the material. In practice, however, we will...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
141
359f8342-b9ac-4016-8bb5-c8305c7cf036
as a basis for more complex theories. They’re also good enough for many applications. So let’s take a look at them now. 5.3.2 C OMPUTING JOINTSTIFFNESS We assumed a simplified, equivalent body shape for a bolt, to make routine calculations of stiffness and deflection less complicated. We have to do the same sort of thi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
141
91e1fbe0-9a34-4a88-a996-092456425c89
have substituted an ‘‘equivalent barrel’’ for the joint [4], but more common substitutions are hollow cylinders [1] or a pair of frustum cones [5] as in Figure 5.9. 5.3.2.1 Stiffness of Concentric Joints A discussion of eight proposed ways to estimate the stiffness of a hard (non-gasketed) joint is given by Motosh [4]....
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
142
cfa5f098-b239-43a8-bf7b-5aac33035c0e
Your own experience, I’m sure, will tell you that limitations 2 and 3 are substantial ones and mean that these equations and recommendations may not apply—at least not very accurately—to many of the joints with which we will be dealing. They’re our only choice at the present state of the art, however, except as noted b...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
142
5747ffc9-0dd9-460e-a66e-36ce28d8f938
2,m m2) T¼total thickness of joint or grip length (in., mm) Note the similarity of this equation to Equation 5.12. The big difficulty here is AC, the cross- sectional area of the equivalent cylinder. The equations we’ll use for ACare summarized in Figure 5.10. Note that there are three different equations, depending on...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
142
3d1bdc48-5691-465a-9b26-d2eeeb22cc4b
outside diameter of the joint ( DJ) [1,7]. If the joint has a square or rectangular cross section, its diameter is the length of one side (or of the shortest side of the rectangle). DHis the diameter of the hole. 5.3.2.2 Stiffness of Eccentric Joints Most bolts don’t run through the centerline of the joint or external ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
143
18f56322-2dc5-4c92-a78c-b1c82f63d772
than the contact area between bolt (or nut or washer) and joint [7]. With reference to Figure 5.11, the area we assume to be loaded by the bolt is AJ. The stiffness equations which follow assume that AJ¼b/C2W ifW/C20DBþTmin ðÞ (5:18a) AJ¼b/C2DBþTmin ðÞ ifW>Z>uþTmin ðÞ (5:18b) TDJ DJ DJDB if then thenif thenDB DJ≥ DB < ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
143
0f728313-d0f2-4b9e-9de1-8d6437e0a97d
In each case b¼tift/C20(DBþTmin) b¼DBþTmin ðÞ ift>DBþTmin ðÞ where W,t,b, andTminare illustrated in Figure 5.11 (all in in., mm) DB¼diameter of contact between bolt head (or washer) and the joint (in., mm) DH¼diameter of the bolt hole (in., mm) If joint dimensions exceed the limits suggested above (for W), the equation...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
144
2d23b3e8-7502-4379-9723-ba67b13bf898
(5.18b) FIGURE 5.11 Sketch of an eccentric joint. The shaded are, b/C2W, can be considered that portion of the joint interface which is loaded by a single bolt. See text for the equations used to estimate this area, AJ.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C005 Final Proof page 98 26.7....
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
144
14e45a9c-2f70-48b6-8fad-2bd85d4e6376
where CJ¼centerline of joint LX¼external load (lb, N) A¼distance between external load and joint centerline (in., mm) s¼distance between bolt axis and joint centerline (in., mm) AC¼cross-sectional area of equivalent concentric cylinder (see Figure 5.10) (in.2,m m2) kjc¼stiffness of equivalent concentric cylinder (see F...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
145
500133e3-578d-4a91-8c62-22c9d716a7ed
RG¼0:289d (5:24) where d¼length of one side.LX LXCJLXCJ CJa s LXa = s (A) (B)whereKJ = 1 rJ/H11033whereKJ = 1 rJ/H11032 rJ/H110331 KJc+1 =s a AC RG2AJrJ/H110321 KJc+1 =s 2AC RG2AJ(5.22) (5.23) FIGURE 5.12 Equations used to compute the stiffness of eccentric joints when the line of action of the external load ( LX) coi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
145
78814ec0-7b8a-4b37-9ce3-c0324a034557
For a rectangular cross section it is RG¼0:289d (5:25) where d¼length of the longer side. For a circular cross section it is RG¼0:25d (5:26) where d¼diameter of the circle. 5.3.3 S TIFFNESS IN PRACTICE Experience shows that the stiffness of a ‘‘typical’’ joint (whatever that may be) is about five times the stiffness of...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
146
72dbc2f6-146a-4caa-9e11-4a5981155fd2
Here’s another way to use Motosh and VDI data to estimate the stiffness of a non-gasketed steel joint. Both sources have published charts on which are plotted the joint-to-bolt stiffnessratio ( K J=KB) as a function of the bolt’s slenderness ratio L=D, where L¼the effective length of the bolt and D¼nominal diameter. Fi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
146
8cb411c6-1aa7-4454-bb34-090fc409d67d
These curves can be used to estimate joint stiffness as follows: 1. Use Equation 5.10 or 5.12 or a version thereof to compute the stiffness of your bolts ( K B). 2. Compute the L=Dratio of your bolt, using the effective length ( LbeþLse) forL. 3. Use Figures 5.14 or 5.15 with your L=Dratio and find the corresponding KJ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
146
b23a98ab-b528-49af-8c4a-261ed4ef66a1
where KJ¼stiffness of a steel joint as estimated from the procedure above (lb =in., N =mm) KJ0¼stiffness of the same joint, but made from an alternate material (lb =in., N =mm) Em¼modulus of elasticity of the alternate material (psi, MPa) Esteel¼modulus of the steel joint material (psi, MPa) 5.4 GASKETED JOINTS We’ve a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
147
24e72dae-4a47-4bd9-a913-7146649cd8e7
Stiffness and Strain Considerations 101
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
147
a20ef9e3-f9e6-4f50-bbf4-9f667a7ea936
the ‘‘soft’’ one will dominate the behavior of the group. Minor changes in the stiffness of springs A and C in Figure 5.16, for example, won’t have much influence on the overall deflection of the train of springs under applied load F. By the same token, changes in the applied force will create a much larger change in t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
148
d6e66be0-a652-49ac-8879-dfe2094b084d
51 0 1 5 FIGURE 5.14 Plots of experimentally determined joint-to-bolt stiffness ratio. Slenderness ratio ( L /D)Stiffness ratio (KJ/KB) 0.200.51.01.5VDI Motosh2.02.53.0 0.4 0.6 0.8 1.0 1.2 1.4 FIGURE 5.15 Plot of stiffness ratio versus slenderness ratio for thin joints. These data, like those shown in Figure 5.14 can b...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
148
3d99cece-3dd9-4a9e-bac1-c8f65f89da43
see in later chapters. And this is true, incidentally, even if the deformation of the gasket is basically plastic, rather than elastic, as is often the case. The force-deflection behavior of a gasket is strongly nonlinear and irreversible (the gasket exhibits hysteresis and creep). Its stiffness, therefore, varies as i...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
149
f8acd17c-bacc-4e31-9e27-5c599da852ad
be determined in an experiment that measures the torque applied to the nut and the angle through which the nut turns as it is being tightened through the straight-line portion of the torque–turn curve shown in Figure 5.10, 6.3, or 8.1. The equation they have derived is KJ¼(DT=Du)=[(KDPK B=360)/C0(DT=Du)] ( 5:28) where ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
149
670d02b7-70c3-42d1-87ab-4d7e079f1b49
straight line. A change in torque ( DT) along this straight line, and the corresponding change in angle (Du), can be used to estimate the stiffness of the joint, as explained in the text.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C005 Final Proof page 103 26.7.2007 6:03pm Compositor Name: BM...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
149
ce1ed26b-2423-4601-9340-2ad529fc66b3
I’ll give the derivation of this equation in Chapter 8, where we’ll take a close look at the torque–turn behavior of the joint during assembly. 5.6 JOINT STIFFNESS RATIO OR LOAD FACTOR Now that we know how to compute or estimate the stiffness of the bolts and of the joint members we’re ready to use this data to compute...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
150
97efe39a-c727-48d2-a167-f8b86a51c12b
KB¼stiffness of the bolt (lb =in., N =mm) KJ¼stiffness of the joint material around a bolt (lb =in., N =mm) In other places, for example, in the German VDI Directive 2230 [10], the stiffness ratio, called a ‘‘load factor,’’ is expressed in terms of the resilience of the parts. Resilience is thereciprocal of stiffness (...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
150
318e92c3-e97b-4f15-ba5f-1788546ede91
joint and the clamping force on it, as in Figure 5.17; and once again the energy stored inthis ‘‘spring’’ is equal to the area under the curve. Theoretically that curve will consist of a straight line with a curve at the upper end if the joint members—or gasket—start to deform
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
150
959b3afe-df9b-4b8e-bfc1-ad7f89f0bbb1
straight line with a curve at the upper end if the joint members—or gasket—start to deform plastically. As suggested in Figure 5.8 and as we’ll see in more detail in Chapters 11 and 16,this picture is a very much simplified illustration of the actual behavior of the joint spring,especially if this is a gasketed joint; ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
150
a2e1b56e-8ff3-4298-8b9e-d269e56f6583
So now—in Figures 5.6 and 5.17—we have pictures of the energy stored in both bolts and joint members. How do we use this information? The answer: we use it only to remind ourselves that stiffness is an important design consideration—because it affects the amount of energy stored in the bolt–joint system. The more energ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
151
88ce5cad-ccb9-47cf-8570-435b2d937b35
bolt having a larger diameter. Let’s tighten the new bolt to the same preload as we tightened the old one. Because the larger bolt is stiffer than the old one, it will deflect less than the old did. Its preload-deflection curve will be steeper—‘‘more vertical’’ if you will see. This means that the area under the curve,...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
151
ffe584c9-37c7-4bc7-b510-a99f793dc029
sensitive to the changes mentioned above. If we couldn’t take a thinner bolt to this preload we might achieve the same effect by using two thin bolts in place of the original fat one, or by using a longer bolt of the original diameter. More length means less stiffness as suggested by Equation 5.12. As an example, consi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
151
b999ff4c-ae67-4c6a-ae05-b177e6c91319
starts to build up, then becomes nonlinear when the joint yields and starts to deform plastically. This assumption is often used for design purposes but doesn’t reflect the fact that the true deformation curve of the joint is nonlinear throughout, especially if the joint contains a gasket.Bickford/Introduction to the D...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
151
dc10f1c8-41a6-4004-883b-269d7bd52e3e
those thicknesses. As we’ll see in Table 9.2, these bolts will have been stretched approxi- mately 0.003 in. per inch of grip length, when taken to proof load (just under yield). So theshort bolt has stretched 0.0015 in., and the longer bolt 0.0023 in. If any of the variousrelaxation effects reduces the deflection of t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
152
60a263c3-ce98-4187-8587-cdc89ed13586
What about the joint? Do we want it to be as resilient as possible? Probably not. First of all, the bolt, being less stiff, will almost always store much more energy than the joint. You might think of the bolt as the active element in the system, with the joint as the passive or resistive element. Second, and more impo...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
152
13f64ba4-3027-4a2b-bc76-6945e32eddf4
EXERCISES AND PROBLEMS 1. Compute the change in length of a medium carbon steel rod of uniform cross section, 0.5 in. diameter, and 4 in. long, when subjected to a tensile force of 10,000 lbs (refer Equation5.2 and Table 5.1). 2. Compute the change in length of a medium carbon steel rod 4 in. long, subjected to a force...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
152
0f93aa2a-0a3a-4cd4-b0dc-131a2c61a0c4
where the grip length is 4.25 in. (refer Table 5.1, Figure 5.3, and Section 2.5.2). 4. Compute the stiffness of the bolt used in example 3 above using Equations 5.10 and 5.12. If the results obtained with these two equations differ, which is more accurate and why? 5. What is the resilience of the example 3 bolt?6. Assu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
152
f1a65f0e-c4d8-4010-8ce6-901290b066aa
REFERENCES 1. Meyer, G. and D. Strelow, Simple diagrams aid in analyzing forces in bolted joints, Assembly Engineering , January 1972. 2.Fastener Preload Concepts , Contract no. F33615-76-C-5251, for Air Force Materials Laboratory, Air Force Systems Command, WPAFB, Dayton, Ohio, by General Dynamics, Fort Worth, June 15...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
153
b067c8fd-3e1e-4657-9dca-194b9f867b44
connections, Reprints of the 2nd International Conference on Structural Mechanics in ReactorTechnology, Berlin, Germany, September 10–14, 1973, vol. Ill, part G-H. 7. Junker, G.H., Principle of the Calculation of High-Duty Bolted Joints: Interpretation of Directive VDI 2230, Unbrako technical thesis, published by SPS, ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
153
b4d56f6e-9eef-4b96-87e2-00a9513dd321
Farmington Hills, MI, 1991 or 1992. 12. Nau, B.S., On the design of gasketed joint, 12th International Conference on Fluid Sealing, Brighton, U.K., May 10–12, 1989. 13. ASME Boiler and Pressure Vessel Code, Section III-Div. 1, 1983 ed., Tables 1–6.0 and 1–7.3, ASME, New York, 1983. 14.1984 SAE Handbook , Vol. 1, Materi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
153
627c71d2-dcfb-4290-81a2-facca0a4ff3a
Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C005 Final Proof page 108 26.7.2007 6:03pm Compositor Name: BMani
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
154
f2a20beb-8d33-41ba-8e28-de6604e75821
6Introduction to Assembly That all-important clamping force which holds the joint together—and without which there would be no joint—is not created by a good joint designer, or by high-quality parts. It iscreated by the mechanic on the assembly line or job site, using the tools, procedures, andworking conditions we hav...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
155
7229ba08-246c-4847-aba6-072596a1e83c
Because of this, the next four chapters will be devoted to assembly, starting, in this chapter, with an overview of the process. How do the bolts and the joint members respondas we tighten the bolts? We’ll see that the behavior of the parts, during assembly, is complex.We’ll take a close look at several unseen, difficu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
155
0cdaa23c-241c-4a1d-b33e-cb2ca9f24d81
In the following three chapters, we’ll look at the many options we have for control of the bolt-tightening process, starting with relatively simple, crude methods and proceeding on toever more elaborate and accurate ones. Our knowledge of the behavior of the bolts and jointduring assembly will help us evaluate the meri...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
155
8a34fc4a-5cc5-456a-b67a-e4436d21740a
6.1 INITIAL VERSUS RESIDUAL PRELOAD The clamping force a bolt exerts on the joint is usually called or equated to the so-calledpreload in the bolt. This term is used in general in most of the literature on bolting to describethe tension in the bolt at any time, but this, in my opinion, is a mistake. I like to think of ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
155
f820843b-2cdc-4ba3-ac49-18a3ff225287
individual fasteners still further. This could be called ‘‘in-service tension in the bolts.’’ Each of these preloads or tensions is directly proportional to the amount of potential energy stored in the bolt, as it is first tightened, or after relaxation occurs, or in service.Bickford/Introduction to the Design and Beha...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
155
4701378a-4ec4-4c89-a834-12a7d6466b97
In most cases these preloads or tensions will also be directly proportional to the clamping force between joint members; but there are exceptions, as we’ll see. But—now that we have these definitions under our belt—let’s get on with it. What happens during assembly? 6.2 STARTING THE ASSEMBLY PROCESS We’re going to asse...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
156
877620c0-7106-4223-bc33-99afc6bedff5
simpler example. Most of the discussion would apply to joints in general. We’re also going to measure the torque we apply to the nuts to control the buildup of initial preload in these bolts. This is the most common, and one of the simplest, types ofcontrol. It will be the subject of Chapter 7, so we won’t go into a lo...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
156
3106d809-188d-4e28-b40f-edd06c45dcd4
6.2.2 T IGHTENING THE FIRSTBOLT To load the joint (and gasket) evenly, we’ll apply the snugging torque in a cross or star pattern,as shown in Figure 6.2. We’d use a similar pattern on a square or rectangular joint if the boltswere all around the edge. In a rectangular, structural joint pattern, with several rows of bol...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
156
f8f5e30c-0ac4-4bf5-8e0f-7cb689a7d59c
FIGURE 6.1 This is a sketch of the large-diameter, pressure vessel joint used as an example in this chapter. We see what happens when we install and tighten the bolts.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 110 26.7.2007 1:37pm Compositor Name: VAmoudavally 110 Intro...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
156
cfcbe5ed-d893-4392-a97e-2c3b14324e92
we’re following basically a two-step procedure: pull the joint together and then tighten it. Because this is a learning experiment we’ll use ultrasonic equipment (Chapter 9) to measure the preload in each bolt as we tighten it. We’ll also measure the angle through which the nut turns after it contacts the surface of th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
157
d7c761b0-5772-4cf8-8b7c-32ffab60dc41
the bolt and in those portions of the joint members which surround it. If that were the case, all of the work we do on this fastener would end up contributing to the clamping force. Unfortunately and unavoidably, most of our input work is lost. Typically, about 90% of the work we do on a nut is converted to heat, thank...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
157
164aa237-c68f-476b-9575-2591b32946d5
We’ll use three passes, at one-third, two-thirds, and final torque, following the same sequence on each pass. Input work Turn Torque TorqueInitial preload FIGURE 6.3 As we tighten the first bolt in our example joint we plot the buildup of initial preload versus applied torque (left-hand diagram) and applied torque vers...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
157
bad9b560-c744-4b53-86ea-a13bb908022f
We’d like to apply a given torque to each bolt and create a given amount of initial preload (the same amount) in each bolt. But the fact that most of the work we do on the nuts is converted to heat makes this virtually impossible, because these frictional losses are extremely difficult to predict or control. Let’s assu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
158