5883b5c7-aea1-462f-9b68-2e81058d0ee6 | the bolt. We started with the assumption that an average of only 10% of the input would be
going into preload; now we’ve lost a fifth of that. This bolt will, therefore, end up with only
80% as much preload as we expected it to. A 4% swing in friction has caused a 20% change in
assembly preload, a very bad leverage sit... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 158 |
8001a99f-6a47-45eb-96e9-fe2c1873fb8c | versus the preload we create in the bolts and the presumably equal and opposite clamping
force on the joint (see Figure 6.5). We then combine these force–deflection curves, plotting the
preload on a common axis, as also shown in Figure 6.5. This creates what the bolting world
calls a ‘‘joint diagram.’’ The pure of hear... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 158 |
e02be42d-dc6d-4a82-a4ef-a93da205d908 | Torque
TurnStored energy
Thread friction
loss
Nut friction
loss
FIGURE 6.4 This diagram shows the approximate way in which the energy delivered to the fastener
joint system is absorbed by it. About 50% of the input is lost as friction-generated heat between
the face of the nut and the surface of the joint. Another 40% ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 158 |
04ba0a8d-6fea-436d-92e9-20aee99f96f3 | These are proportional to the slopes of the two straight lines, and, as we saw in Chapter 5, can
be computed as follows:
KB¼FP=DL (6:1)
KJ¼FP=DT (6:2)
where
FP¼preload in the bolt and joint (lb, N)
DL¼deflection (stretch) of the bolt (in., mm)
DT¼deflection (compression) of the joint (in., mm)
KB¼stiffness of the bolt ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 159 |
8531cf83-2765-4cf4-bf6f-c80961b91cdf | now, however, we’re merely interested in using the joint diagram to illustrate the preloading
of the bolts.
Our boss, who has already read a previous edition of this book, uses Equation 7.4 in the
next chapter to compute the average preload he expected us to get in this first bolt when we
applied 225 lb-ft of torque to... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 159 |
665a06f0-d4bd-4193-9b9f-48f5133ea2c7 | compressionor changeinthickness ( DT)ofthe joint. At this pointweassume thatthepreloadwill beequal
to the clamping force. These two plots are shown at the top of this illustration. We then combine those two
plots, as shown at the bottom of this illustration, to start constructing what we’ll call a joint diagram.Bickfor... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 159 |
b1dab1a5-84df-4ac1-8635-5d77f7e07e4a | Has this really created 9,600 lbs of clamping force between joint members? Our joint
diagram assumes it has, but the correct answer is ‘‘probably not’’—at least as far as this first
bolt is concerned. Remember that we had to tap some of those bolts into their holes? This
implies that there was contact between the sides... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 160 |
ed41ecab-0629-4833-aba9-6a6f3c3a8d1e | process.
6.3 BOLT PRELOAD VERSUS CLAMPING FORCE ON THE JOINT
The main purpose of the bolts is to clamp the joint members together. A common miscon-
ception is that there is always an equal and opposite action–reaction relationship between the
tension in the bolts in a joint and the thing we’re interested in, the clampi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 160 |
1e41258c-3c5e-4cf0-82fd-5c12358811ba | nut. Our goal is to clamp the joint members together. The hole in the upper joint member is
undersized, so the stud is a press fit in this member.
Thanks to frictional and embedment constraints between the sides of the bolt and the
walls of the hole, it will take some positive force to pull the bolt through the hole, a... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 160 |
f8b2991c-f1d0-4cae-addb-c6afe9dc80a4 | The force is created, obviously, when we turn the nut, creating tension in the bolt. Thanks
to hole interference, some of this tension will not end up as clamping force between joint
members. Part of it will be lost as the bolt fights its way past the walls of the hole.
I’m sure you can envision the extreme case in whi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 161 |
4120b739-544c-4b99-819d-cd87d03cc5dd | Hole interference is used on purpose by the airframe industry, for example, to reduce the
possibility offatiguefailureof the shear-loadedjoints used inairframestructures.(Compressive
stress built up in the walls of the bolt holes fights the formation or growth of fatigue cracks.)
The holes are purposely drilled smaller... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 161 |
06d5bbf1-6d85-46cd-b45b-2971e42731e1 | One airframe manufacturer recently measured the amount of force required to pull bolts
of a given nominal diameter through holes drilled in plates of varying thickness. Some of the
results are shown in Figures 6.7 and 6.8. The bolt and hole diameters used in the experiment
varied through the full range of the manufactu... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 161 |
6969c9a1-d375-4438-b221-b83d7253f8f1 | 0.5 1.0 1.5 2.0 2.5 3.0
Interference (in. /H11003 10−3)3.5 4.0 4.5 5.0 5.5 6.0 6.5Interference versus insertion force
2024 AL plate, WQ fastener516
= Plate34= Plate12+= Plate14
FIGURE 6.7 Chart showing the force required to push,5=16in. fasteners through interference fit holes in
aluminum plates varyin... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 161 |
b82e6987-c778-45c1-b0c8-55ac586dafe9 | counted on to pull all of the bolts through their holes, much less go on to develop any
clamping force between joint members. In spite of this, the same torque is specified by the
airframe manufacturer for all bolts of a given diameter, without regard to the amount of hole
interference seen by a given bolt or the thick... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 162 |
4e09f2c8-0f6d-4cab-80e7-72fbaf693e1f | Another factor which can rob from the clamping force between joint members is shown in
Figure 6.9. A heavy cover is being lifted up against a flange on a pressure vessel. As shown
in the figure, the joint members have not yet been brought into contact, but we are turning the
nut on the stud to bring them into contact. ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 162 |
3123d47c-28ce-4a37-baca-72a93e2cea40 | Eventually the two joint members will be brought into contact. Further torque, at this
point, will be required to create a clamping force between joint members to load the gasket.
That torque should presumably be added to the torque required to pull the joint members
together in the first place, but it rarely is in pra... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 162 |
dbc665a3-db8e-467a-8c71-74fca73d8e88 | to thrust5=16in. fasteners through interference fit holes in aluminum plates of various thickness,
summarizing some of the data shown in Figure 6.7. The three bars on the left side of the chart show
the nominal preload which would be generated by5=16in. bolts if tightened to 50% of yield. Three
bolt materials are shown... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 162 |
ca854b3e-f28c-49f6-9b75-fdc4d890a4a5 | such situations. We learned of one situation in which large windmills are lowered to a
horizontal position so that new, heavy blades could be attached. And these blades were raised
by tightening the bolts, which fastened them to the structure. Although this kind of thing is
rare, it is fairly common for large joint mem... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 163 |
3627770d-a724-4398-bd31-601356a68175 | can’t. I have never seen anything in the literature on this subject either. Yet I’m convinced that
this factor can seriously degrade the relationship between tension in the bolts and clamping
force between joint members, especially in large joints, as one example. Warped or nonflat
(e.g., wavy) joint members, incidenta... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 163 |
9efcfa66-40d0-4d8b-b28a-faa41888f4f6 | etical calculations and conducted experiments to determine the forces, stresses, and moments
in pipes and flanges when the flanges are misaligned. They used a hydraulic tensioner, for
example (see Chapter 9), to measure the force required to pull misaligned flanges together,
as shown in Figure 6.10. The chart in Figure... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 163 |
bac11395-504a-4332-ba01-0561f3a5e5b2 | hanger or intersection with a larger pipe).Vessel
Cover
WeightGasket
FIGURE 6.9 Heavy and misaligned or warped joint members can also affect the relationship between
the torque applied to the fastener, the tension in the fastener, and the clamping force between joint
members.Bickford/Introduction to the Design and Beha... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 163 |
4f1a16f2-08bb-4078-b0a2-892a44238241 | As a result of these studies, Puget Sound developed some flange parallelism criteria,
designed, as I understand it, to keep pipe stress below 3 ksi near any flange which is connected
to turbines or other rotating equipment. Pipe stresses beside flanges located 50 or more pipe
diameters away from rotating equipment were... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 164 |
08efbbc1-9b37-4569-9141-626079aa5210 | function of the size of the ‘‘gap’’ shown here.
0.025 /H11033
0.020 /H11033
0.015 /H11033
1051015
2345
Pipe size (in.)Adjacent pipe stress (ksi)
678
FIGURE 6.11 A plot of the stress in the pipe adjacent to a misaligned flange versus the nominal diameter
of the pipe, for misalignment gaps of 0.015, 0.020, and 0.025 in. ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 164 |
fdf8d408-6a18-48e5-b49e-37721cf4ec7e | 6.4 CONTINUING THE SNUGGING PASS
We’re now going to continue tightening the 16-bolt gasketed, flange joint we’re taking as an
example in this chapter. We apply the snugging torque of 225 lb-ft to each of those bolts,following the cross-bolting pattern shown in Figure 6.2. We measure the preload, turn, anddeflection in ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 165 |
cdbdb9a6-6631-43b1-9e40-08affcd045fd | surfaces. Everyone’s happy, so we now go out and have lunch.
When we come back from lunch we find our boss’s boss on the job site, reviewing our
data. He wants to see how we managed to measure the tension or preload in these bolts, so weplug in our ultrasonic instrument and remeasure the preload in bolt number one, the... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 165 |
35a63fff-d846-4ee5-bddf-96b1f5f77639 | which some people call ‘‘torque loss.’’ Here’s what he says.
6.5 SHORT-TERM RELAXATION OF INDIVIDUAL BOLTS
Whether or not there’s a one-to-one relationship between bolt tension and interface clampingforce, there will often be some initial loss of tension in individual bolts after they are initiallytightened. Let’s call... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 165 |
c939bdfc-013b-4c6a-ac7e-1e196f1f574a | 6.5.1 S OURCES OF SHORT-TERMRELAXATION
Here are some things which can cause relatively short-term relaxation, starting with the mostcommon of all—embedment.
The surfaces of the threads in the nut, the bolt, and the faying surfaces of the structural
members, washers, etc. are never perfectly flat, even if such parts are... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 165 |
7e5ae4ab-a6a0-4555-a212-0e17534b94fc | Since initial contact areas are relatively small, the metal at the contact points cannot stand
the pressures. Plastic deformation occurs until enough of the total thread surface has beenbrought into play to stabilize the situation and support the load without further deformation.
The same thing happens in the faying su... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 165 |
66541396-e7c2-4317-80c4-0de738fd40b6 | Many of these surface high spots are smoothed away during the tightening process [1]—at
least they will be if the fasteners are torqued. Hydraulic tensioners don’t load the active threads,or even the joint surfaces underneath the nut or washer, until they let go off the bolt. As a result,there is often more embedment r... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 165 |
5c714c93-0c8c-4fb7-bb5f-0dc0e61a0963 | Embedment is worse on new parts than on reused ones. In critical applications it can be
minimized by tightening, loosening, and retightening the fasteners several times. This is done
on camera mounts in space satellites, for example [2].
6.5.1.1 Poor Thread Engagement
If the bolt is undersized, or the nut oversized, th... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 166 |
dbd035bc-d9e3-4b37-baeb-451051a9ea3b | 6.5.1.2 Thread Engagement Too Short
The length of thread engagement for steel fasteners should be at least 0.8 times the nominal
diameter of the fastener. If the engagement length is too short (too few threads supportthe load), thread contact areas are again smaller than those intended by the fastenermanufacturer and e... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 166 |
7c4b2cdc-d544-4518-8d63-ea674f4211e2 | into contact to stabilize the joint. The process is called embedment.
FIGURE 6.13 Poor thread engagement may be a major source of plastic deformation and therefore joint
relaxation.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 120 26.7.2007 1:37pm Compositor Name: VAmoudav... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 166 |
d4e85b41-cbd6-4890-9264-29efa91d79ba | 6.5.1.3 Soft Parts
If parts are softer than intended by the designer—perhaps because of improper heat treat or
incorrect material—they may creep and relax substantially even if the geometry is correct andloads are normal.
6.5.1.4 Bending
If the fastener is bent as it is tightened, it will see higher stresses along one ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 167 |
2bfad2ff-ed83-4583-af11-b2f483be5c5b | 6.5.1.6 Fillets or Undersized Holes
If the head-to-body fillet contacts the edge of the bolt hole as shown in Figure 6.14, the edge
of the hole will break down under initial contact pressures. This may result in a complete loss
of preload, since such effects are usually large compared to the amount by which the bolt wa... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 167 |
2b3d2779-dc74-4507-8325-3ca65ee1e711 | increase relaxation appreciably [5].
6.5.1.8 Conical Makeups
Surface irregularities will exist on conical joint surfaces as well as flat ones. The effect on axial
tension in the fastener, however, is magnified if the embedment occurs on conical surfaces.
FIGURE 6.14 Oversized fillets and undersized holes may result in ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 167 |
d44c08fb-5ae6-48f9-85d3-7ff55bcb9595 | A given amount of relaxation perpendicular to the surface may mean substantially greater
relaxation in the axial direction, as suggested in Figure 6.16 and Equation 6.3.
r¼e
sinu(6:3)
where
e¼embedment relaxation perpendicular to the surface of a conical joint member (in., mm)
r¼resulting relaxation parallel to the axi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 168 |
83729be2-b0bc-48c1-ac65-30b4bec7feaf | relaxation.
Fastener
centerline
e
r
q
FIGURE 6.16 Conical or tapered joints usually relax more than flat ones for reasons given in the text.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 122 26.7.2007 1:37pm Compositor Name: VAmoudavally
122 Introduction to the Design and B... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 168 |
1fc99705-f601-4446-9705-175fa5eac3a4 | 6.5.2.1 Bolt Length
Long, thin bolts will relax by a smaller percentage than short, stubby ones. The total embed-
ment relaxation or the like will be the same for a given initial preload, but that embedment
will be a different percentage of the total length of the bolt and therefore will mean a different
percentage los... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 169 |
6847ed68-c4b4-4ad8-ad1c-6e4fc3e301e7 | embedment is to use Belleville washers, as also shown in Figure 6.17. These springs have a
very flat rate, compared to the stiffness of either bolt or joint members. They will therefore
determine (limit) the preload and clamping force in the system (see Figure 5.16). Because of
their flat rate, a small deformation in t... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 169 |
b9bc145b-2ba6-413c-b154-584b6d69dfde | now more high spots to embed and settle in together. Doubling the number of contact
surfaces, for example, will almost double relaxation in many cases [6].
6.5.2.4 Tightening Speed
Creep and flow take time. Fasteners that are tightened very rapidly won’t have time to settle
in together during the tightening process and... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 169 |
81b5150a-be2f-404e-b4bc-21aa3ad8a7e3 | examined in Chapter 7. You tighten the fasteners with high-speed tools, but pause once or
repeatedly to give the parts time to relax.
Tightening bolts in a series of passes, rather than applying full torque on the first pass,
allows time for relaxation. This procedure also pulls the joint together uniformly. For both o... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 170 |
c406d0e4-c2a9-49e8-8416-e5849be8228a | interactions between fasteners, discussed in Section 6.6 of this chapter, are almost certainly
involved here as well.
6.5.2.6 Bent Joint Members
If joint members are soft or warped or bent, tightening one fastener can cause relaxation (or
additional stress) in other fasteners. This sort of ‘‘cross talk’’ between fasten... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 170 |
046c791b-0578-47fc-b249-0cf1a7a03c7c | some anticipated mean.
In general, fasteners relax rapidly following initial tightening, then relax at a slower rate,
following the pattern shown in Figure 6.18. The amount of relaxation varies greatly, depending
on the condition of the parts, finishes, initial and local tension levels, fit of parts, and all of the
oth... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 170 |
4a3f2a11-49e4-411c-ba6e-db765b6ca118 | structural steel showed a loss of 2%–11% of preload immediately after tightening, followed by
another 3.6% in the next 21 days, followed by another 2% in the next 11.4 years [5, p. 61].Bethlehem Steel reports that only 5% of the initial tension will be lost in structural bolts set byturn-of-nut techniques 5% over the t... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 171 |
a16f964d-8d92-46f3-b03a-337f7a262d2b | variety of results on a variety of structural bolts, different types of bolt heads, different nuts,
with and without washers, etc. [11]. As one example, an A325 bolt with a regular (not heavy)head, a flanged nut, and no washer relaxed 2.6% in the first minute after tightening (most ofthis in the first 15–20 s). It had ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 171 |
02f0dbfc-eadf-4345-aded-be9f7571a31d | in.-lb. This is not all embedment, as we’ll see in Section 6.6.
Gasketed joints will relax substantially, whether the bolts are torqued or tensioned. This is
especially true during preliminary passes, when loss of as much as 80%–100% of initial tensionis not at all uncommon for reasons to be discussed soon. Gaskets wil... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 171 |
4b6d90ac-eee9-44ef-8e39-10ffc39edc8d | 6.5.4 T ORSIONAL RELAXATION
We’ve been looking at preload or tension relaxation. This is of prime importance to us,because of the general importance of correct preload. We mustn’t forget, however, thattorsional stress is also built up in a fastener as it is tightened, and that this stress is alsosubject to varying amou... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 171 |
5b6a0e72-c043-4d46-b47e-87bb0efb8a7c | Figure 6.19 shows the tension and torsion relaxation we measured in an experiment with a
2
1=4–8/C212 B16 stud, which had been lubricated with moly. Torsion relaxed 50% when the
wrench was removed; tension actually increased 1%–2% during this period. We have sub-sequently seen this phenomenon on many other types and si... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 171 |
d8ae3a1c-5c74-4fe0-9eb8-0f69e1df5256 | the face of the nut.
Sizable relaxation of tension, occurring as the torsional stress disappears, can, of course,
mask this exchange of torsion for tension. Thus we’ve observed this exchange only on hardjoints. But it’s relatively easy to reproduce, and we think its common. Many bolts in large jointsmysteriously ‘‘grow... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 171 |
a01c1229-5f0c-4dbb-b4d2-829109a43488 | A torque wrench appears to respond to torsional stress levels in the bolt as well as to preload
levels. The torque required to restart a nut can be less than that required to tighten it in the firstplace,eveniftherehasbeennolossinpreloadinthemeantimeiftorsionalstresshasdisappearedor been reduced. Repeated‘‘torquerecove... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 171 |
54485fc3-4f9d-415c-a840-b316461c7c62 | now relaxed to a stretch of only 0.001 in. We reapplied 150 lb-ft of torque, and the stretch
returned to 0.0014 in. Incidentally, it took only 100 lb-ft to restart the nut.
The bolt now relaxed again, was tightened again, relaxed some more, and so on, as shown
in Figure 6.20. Final preload (stretch) was 33% greater tha... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 172 |
c8e77309-a030-43ac-9b6d-7efb72bbe9e3 | applied repeatedly to this fastener, with a pause for relaxation between each pass. Final preload was 33%
greater than that achieved on the first pass.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 126 26.7.2007 1:38pm Compositor Name: VAmoudavally
126 Introduction to the D... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 172 |
2b99d2c6-0020-4ea0-873a-5e44fe52ecab | even though we never applied more than the initial 150 lb-ft of torque. The final restarting
torque was still only 87% of the rated torque. Many mechanics would conclude from this thatpreload was still 13% below the initial value. This possible interaction between torsional andtension stress further complicates the tas... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 173 |
c702e48d-e9a5-4d60-b710-740bed30225e | Let’s assume that we’re planning to tighten a circular, flanged joint that contains eight
bolts. We’re going to use ganged hydraulic wrenches or hydraulic tensioners to tighten thesebolts two at a time. The bolts we tighten simultaneously, of course, will be opposite each other
on the flange, 180 8apart.
To explain the... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 173 |
1e7ff1a0-5c61-4e26-a013-185a98bdc7b8 | The 20,000 lbs of force that these two bolts are creating on the joint partially compress the
joint. We now go on to tighten bolts 3 and 4 located 90 8away from bolts 1 and 2. Again, our
tools work magic for us and we create exactly 10,000 lbs of initial preload in bolts 3 and 4when they are tightened (Figure 6.22).
We... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 173 |
e826c462-1ac2-4491-ae7b-91340c12f187 | little as the joint is compressed by bolts 3 and 4.
At this point in the process, therefore, bolts 1 and 2 have a slightly lower amount of
preload in them than bolts 3 and 4—even though each of the four bolts started with the same
FIGURE 6.21 A simulated model of a bolted joint, in which the joint members are represent... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 173 |
ce550dd5-8688-4e87-acba-32ffedf56260 | initial tension of 10,000 lbs. When we now go on and tighten bolts 5 and 6 in a third step, bolts
3 and 4 will relax a little, and bolts 1 and 2 will relax further. Tightening bolts 7 and 8 to
complete the assembly will create relaxation in each of the six bolts tightened earlier.
The result is four different levels of... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 174 |
6483238b-26d9-4331-9454-8e2bae637cc7 | gasketed joint with a spiral-wound, asbestos-filled gasket was tightened in three passes
using a cross-bolting pattern and tightening one bolt located 180 8away from bolt 1. The
third and fourth bolts tightened are halfway between bolts 1 and 2, etc. The difference
between the ‘‘x’’s and solid line shows the loss of in... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 174 |
d1785097-e47a-4b88-8b24-6a70c798c7e1 | horizontal axis show the location of the bolts, and the order in which they were tightened. The second
bolt tightened, bolt 2, is located 180 8away from bolt l. The third and fourth bolts tightened are halfway
between bolts 1 and 2, etc. The difference between the x’s and solid line shows the loss of initial preload
in... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 174 |
23d2c8ed-7bc6-4bdf-95f2-f639c6e66f50 | The isolated ‘‘x’’s show the initial change in length achieved in each bolt as it was
tightened individually. This change in length, or stretch, is proportional to the tension in
the bolt, as we saw in Chapter 5 (or will see at greater length in Chapter 9). The sawtooth line
shows the pattern of residual preload (stret... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 175 |
5d9cace1-81a0-4306-9728-1fb251c646a9 | in that bolt by the 100 ft-lb of torque. After all the bolts in the joint had been tightened,
however, the tension in bolt 1 was remeasured, and it was found to have only about 1.5 mils
of stretch. Bolt 3 started and ended about the same place. Bolt 6 started with about 2 mils, but
lost all but 0.25 mil as the other bo... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 175 |
08d1a477-0c59-4f04-96c4-710f76f3f9e2 | started to break up and become more erratic. Note, too, that at this point in the procedure the
scatter between maximum and minimum residual tension in the bolts is nearly 20:1, ranging
from less than 1 mil of stretch in the bolt tightened fourth to nearly 8 mils of stretch in the108 124 146 162 15
Order tightenedStret... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 175 |
fbe29f3f-0508-4732-a313-f2e217517577 | eleventh bolt tightened, and this despite the fact that the scatter between maximum and
minimum tensions created in individual bolts as they were first tightened is fairly normal. Inpass 1, for example, the scatter between applied torque and achieved initial preload wasroughly +30%, as anticipated for as-received steel... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 176 |
ae055916-5763-46c4-ad4b-8ab4de9202b3 | The fact that we were using a torque wrench to tighten these bolts contributes somewhat
to the initial bolt-to-bolt scatter in tension, of course. But the elastic interaction contributesfar more to the final scatter, and has nothing to do with the type of tool used. Figure 9.11, forexample, shows similar results obtain... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 176 |
b93139ee-da28-4f45-8252-e1c30a5a908a | be less significant in the gasketed joint because this joint has a ‘‘memory.’’ Its leak behavior
depends as much upon the initial preload developed in its bolts as it does to the residualpreload. You’ll find a complete discussion of this in Volume 2 of this text.
Is there any way to prevent or eliminate elastic interac... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 176 |
c10410e8-1abe-44ff-b8c5-9e99858982a5 | single pass. One might, for example, apply 400 ft-lb of torque to bolts 1 and 2; 300 to bolts 3
and 4; 200 to bolts 5 and 6; and 100 to bolts 7 and 8. Bolts 1 and 2 relax three times; bolts 3 and4 relax twice; bolts 5 and 6 relax once; and all end up with the same amount of tension finallycreated in bolts 7 and 8.
Seve... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 176 |
b5294f0d-4411-45c8-bffb-5de0a40d95a4 | This is illustrated in Figure 6.26, which shows the results achieved in another experiment
on the joint described in Figures 6.23 through 6.25. The bolts were tightened in three passes as
before, but the final pattern of preload differs significantly from that shown in Figure 6.25.
This time, in an experiment to reduce... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 176 |
55bcf5e1-e01e-4437-abb2-495d28dbefbb | way from the +30% often claimed for torque procedures in general.
We’ve tried other torquing procedures to reduce final scatter. For example, we’ve tried
making a final pass at 75% of final torque on the odd-numbered bolts only; tried using a largenumber of passes (15 or 20) at the final torque; tried making several pa... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 176 |
38f1f221-20c5-4d2a-80e2-f0325c2fc2db | what pattern or format is used. Scatter is reduced slowly as the number of passes increases.
But scatter cannot be eliminated by any ‘‘torquing’’ procedure I know of. If ultrasonics or
datum rods or load cells can be used to monitor results, a different torque can be applied to
each bolt and scatter can then be reduced... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 177 |
cafb0ea6-cf1d-4945-b310-5b64ba4c2c35 | tive engine heads, for example. The closer you can come to simultaneous tightening, the less
elastic interaction effect you will get. For example, if you can tighten half the bolts in the joint
simultaneously, you will see less interaction than if you tighten them individually or tighten
one-quarter of them at a time.
... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 177 |
b9ea3c83-b59d-4ba7-9d83-26053cf641b8 | rather than a decrease in preload scatter, although both are sometimes required. We can now
modify our joint diagram to show the loss in preload created by embedment and by the
average elastic interaction effect, as in Figure 6.27. The dashed lines show the situation—bolt
and joint forces and deflections—before relaxat... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 177 |
b1be5095-2810-48df-aba9-977ebf67e49d | scatter of only +2% or so, in large-diameter gasketed or ungasketed joints. (His tests
involved flanges with diameters of 16 and 24 in.) Using a cross-bolting pattern, he first
tightens the bolts to an arbitrary, experimental tension, which he monitors with strain
gages or ultrasonics. During this pass he determines th... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 177 |
cfccb15c-c444-44a0-bc84-397e852889b1 | same torques and procedure used earlier. The solid line shows the change in pattern of residual tensions
after a fourth and final pass in reverse order (the last bolt was tightened first).Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 131 26.7.2007 1:38pm Compositor Name: V... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 177 |
67e30e3a-a1bb-4c4c-8f51-408b84894592 | single, cross-bolting pass, determining the amount each is to be tightened by use of a matrix of
interaction coefficients derived from the data taken during the experimental pass. Once again,
tension and not torque is used to determine the initial preload developed in each bolt during
this final pass. He believes that ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 178 |
73312587-9903-4b93-af02-5cfe19a3f713 | He also reports that the elastic interactions in a given joint appear to be repeatable, and
therefore predictable, which would suggest that the interaction coefficients would have to be
determined only once for a given joint. Finally, he reports that the first bolt tightened in a
cross pattern can be overloaded by up t... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 178 |
86278225-41cd-40eb-b62e-df3be93f8a1a | amount of clamping force created on a multibolt joint when it’s tightened. We include a few
things learned in earlier chapters or elsewhere; for example, the fact that some bolts will be
bent slightly if tightened against nonparallel joint surfaces (as discussed in Chapter 2). We
also include some minor factors not dis... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 178 |
7da1619f-1bbf-452f-a604-cabaac9e2e92 | ment reduces the initial preload by an amount shown as A. The average loss in a group of bolts, caused
by elastic interactions, is shown as loss B. We use the average loss instead of the individual loss because
joint behavior will more likely be determined by average loss than by worse case. The final, average,
residua... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 178 |
e3f5ec6c-2d3f-4c69-ba42-a6dec8d4a943 | Apply input to bolting tool
Torque
on nut
Which results in-Heat loss
in tool
Twist
(torsion)
of boltAxial
force
on boltHeat loss
in threads
and nut/joint
interfaceBending moment
on bolt (if
surfaces not
parallel)Elastic/plastic
deformation of
reaction and drive
members
Bending
stress
Initial clamping
force on joint
int... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 179 |
78c52325-8abe-4227-b654-d0bb7c3e149d | from joint members on
bolts tightened earlierEmbedment and/or creep
of gaskets, burrs, threads
joint members reduces the
“plastic reaction force”
on all bolts with time
Residual clamping
force on joint
interface
Repeat all
blocks after
“torque on nut”
above
Working loads on the joint
Inertia
Pressure
Weight
Axi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 179 |
3418e681-2d18-4f19-97d6-7225c7205171 | from assembly operations
Which may be subsequently modified in service by Force on wrench handle
Hammer blow
Air or hydraulic pressure
Etc., creating
In field maintenance
operations-Resistance of joint
members to being pulled
into contact (if any)
FIGURE 6.28 Block diagram showing most of the factors which affec... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 179 |
c808806f-b2c0-428d-a290-9b56fb13795f | Because of our interest in stored energy, we also list the many ways the input work we do
on the nuts is absorbed by the bolts and joint members. The work
.Heats the parts and tools
.Enlarges interference fit holes
.Bends and twists the bolts
.Dilates the nuts (see Chapter 3)
.Pulls the joint members together
.Overcome... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 180 |
4659efa2-369b-4f4c-af5f-63ab3cb4ca55 | as the parts embed and relax.
We now realize why accurate control of the assembly process is so difficult. We would
have to predict or control such unpredictable things as the friction forces between parts, theeffort required to pull the joint together, the amount of hole interference, and the elasticinteractions betwe... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 180 |
a9f5342f-cf38-4018-ab69-a6d7f4f01360 | Regardless of the type of control we adopt, furthermore, there are a number of relatively
simple things we can do to improve our chances of success during assembly operations. Infact, the things listed below can often make more improvement than the use of elaborate or
expensive preload control equipment. As you can see... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 180 |
0cf024ec-6083-433f-af2f-1be9252bb1fc | 3. Make sure the fasteners are in reasonable shape. Wire-brush the threads if they’re dirty
and rusted. Use stainless steel bristles on alloy steel materials. Chase threads with a tapor die if they’re damaged. Or replace the bolts with new ones!
4. Use hardened washers between the turned element (nut or bolt head) and ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 180 |
dd58b0f4-a89c-4a62-b13b-67a5d69e0200 | 7. Hold wrenches perpendicular to the axes of the bolts.
8. Apply torque at a smooth and uniform rate. Avoid a stick-slip situation as you
approach the final torque. If necessary, back the nut off a little so that the specifiedtorque can be reached with the wrench in motion.
9. If hydraulically powered wrenches are use... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 181 |
cb3bf040-bceb-41cb-be59-c166ca309e3e | rectangular (as in a structural steel joint). Work in a cross-bolting pattern on circularor oval joints.
12. Keep good records of the tools, operators, procedures, torques, and lubricants used.
Bolting is an empirical ‘‘art’’ at present. If you record details of your ‘‘experiment’’you’ll have the information you need t... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 181 |
8f4dbbd0-717e-4ada-8f67-b06ed9e7d335 | an individual bolt?
3. Is the preload mentioned in question 2 above initial or residual preload?
4. What would be the result if we lubricated the bolts in a given joint for the first time and
reduced the friction loss during tightening by 3%?
5. Why do individual bolts relax a bit when first tightened?
6. Name several ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 181 |
34321b08-5823-4e72-bb88-a8ce2f130aee | REFERENCES
1. Landt, R., Preload Loss and Vibration Loosening , SPS Technologies, Jenkintown, PA, 1979.
2. Conversation with Carl Osgood, Consultant, Cranbury, NJ, 1974.
3. Friesth, E.R., Performance characteristics of bolted joints in design and assembly, SME Technical
Paper AD77-715, 1977.
4. High strength bolted joi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 181 |
e2a54c23-8d67-4272-b2dd-c3b8992bf206 | 8. Prodan, V.D., et al., More precise load-relief factor for tightened screw connections, Vest. Mashin. ,
vol. 54, no. 1, pp. 27–28, 1974.
9. Junker, G., Principles of the Calculation of High Duty Bolted Connections-Interpretation of Guideline
VDI 2230 , VDI Berichte, no. 220, 1974, published as an Unbrako technical th... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 182 |
159a482e-b0b8-40ea-8ca2-170dbd563672 | January–February 1973.
13. Hardiman, R., Vibrational loosening-causes and cures, Presented at the Using Threaded Fasteners
Seminar at the University of Wisconsin-Extension, Madison, May 8, 1978.
14. Investigation of threaded fastener structural integrity, Report prepared by Southwest Research
Institute, San Antonio, Te... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 182 |
76d43749-1f47-4807-9dc5-ac73950a7b2b | applicable to high-pressure apparatus, Khimicheskoe i Neftyanoe Mashinostroenie , no. 2, pp. 3–5,
February 1973.
18. Tripp, Owen S., and Earl D. Stevens, Flange parallelism criteria, presented to the PVRC Subcom-
mittee on Bolted Flanged Connections, San Francisco, CA, January 1983.
19. Bibel, G. and R. Ezell, An impro... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 182 |
d3e2f824-a06a-4e17-8528-4ac1298ef71f | and elastic interaction effects, Fastener Technology International , February 17, 1994.
22. Bibel, G., ‘‘Tightening groups of fasteners in a structure and the resulting elastic interaction,’’ in
Handbook of Bolts and Bolted Joints , John H. Bickford and Sayed Nassar (Eds.), Marcel Dekker,
NY, 1998.Bickford/Introduction... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 182 |
e82f658b-29b0-4814-9171-9331f29c068c | 7Torque Control of Preload
We have now reviewed the assembly process and have seen why the control of that
all-important clamping force on the joint is so difficult. During this review we assumedthat we were using the torque applied to the nut to control the tension or preload built-upwithin the bolt. Now we’re going t... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 183 |
119c3773-4424-4f66-983e-050590935593 | as a means of evaluating the residual preload in a bolt.
In later chapters we’ll study other means of controlling assembly preloads. But make no
mistake: at this point in time, torque is king. It’s by far the best-known, most common, andusually the least expensive way to control preload. It doesn’t do a perfect job, bu... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 183 |
eac49680-6640-48c1-80fd-3b0d6b627c60 | the other.
During initial assembly of an individual bolt there’s a one-to-one relationship between the
tension in a bolt and its preload. As we saw in the last chapter, however, the tensile load in a
bolt will change as we tighten other bolts or put the joint in service, so the preload is an initialand short-lived affa... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 183 |
12a754d9-20ff-45a7-9274-75b8d1383eed | all bolts have been tightened.
The tension in a bolt in service : We’re most interested in the last one on this list, the tension
in the bolts while they’re in service, but in this and the next two chapters we’re going tofocus on the initial preload we get when we first tighten a bolt. This is the preload overwhich we ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 183 |
1f40b53c-4704-4e89-b9e7-05ae4ccdf477 | 7.1.1 P ROBLEMS CREATED BY INCORRECT PRELOAD
We’ll take a closer look at these points in later chapters, but here’s an introduction to the
problems created by incorrect preload.
1.Static failure of the fastener : If you apply too much preload, the body of the bolt will
break or the threads will strip.
2.Static failure ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 184 |
5bc75587-6501-4c7b-a5c1-f578dbf4e837 | 5.Stress corrosion cracking : Stress corrosion cracking (SCC), like fatigue, can cause a
bolt to break. Stresses in the bolt, created primarily by preload, will encourage SCC ifthey’re above a certain threshold level, as we’ll see in Chapter 16.
6.Joint separation : Proper preload prevents joint separation; this means ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 184 |
a9631bbe-9dcd-4f56-bb78-12a49667413a | 8.Excessive weight : If we could always count on correct preload, we could use fewer and
smaller fasteners, and often smaller joint members. This can have a significant effect
on the weight of our products.
9.Excessive cost : The cost of many products is proportional to the number of assembly
operations. Correct preloa... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 184 |
f4da1d14-dbf1-4b35-9f05-e9ff73ee9a58 | 7.1.2 H OWMUCHPRELOAD ?
We always want the maximum possible preload, but in choosing this, we must consider:
.Strength of the bolt and of the joint members under static and dynamic loads
.Accuracy with which we expect to tighten the bolts
.Importance of the joint, i.e., the factor of safety required
.Operating environm... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 184 |