the bolt. We started with the assumption that an average of only 10% of the input would be going into preload; now we’ve lost a fifth of that. This bolt will, therefore, end up with only 80% as much preload as we expected it to. A 4% swing in friction has caused a 20% change in assembly preload, a very bad leverage sit...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
158
8001a99f-6a47-45eb-96e9-fe2c1873fb8c
versus the preload we create in the bolts and the presumably equal and opposite clamping force on the joint (see Figure 6.5). We then combine these force–deflection curves, plotting the preload on a common axis, as also shown in Figure 6.5. This creates what the bolting world calls a ‘‘joint diagram.’’ The pure of hear...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
158
e02be42d-dc6d-4a82-a4ef-a93da205d908
Torque TurnStored energy Thread friction loss Nut friction loss FIGURE 6.4 This diagram shows the approximate way in which the energy delivered to the fastener joint system is absorbed by it. About 50% of the input is lost as friction-generated heat between the face of the nut and the surface of the joint. Another 40% ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
158
04ba0a8d-6fea-436d-92e9-20aee99f96f3
These are proportional to the slopes of the two straight lines, and, as we saw in Chapter 5, can be computed as follows: KB¼FP=DL (6:1) KJ¼FP=DT (6:2) where FP¼preload in the bolt and joint (lb, N) DL¼deflection (stretch) of the bolt (in., mm) DT¼deflection (compression) of the joint (in., mm) KB¼stiffness of the bolt ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
159
8531cf83-2765-4cf4-bf6f-c80961b91cdf
now, however, we’re merely interested in using the joint diagram to illustrate the preloading of the bolts. Our boss, who has already read a previous edition of this book, uses Equation 7.4 in the next chapter to compute the average preload he expected us to get in this first bolt when we applied 225 lb-ft of torque to...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
159
665a06f0-d4bd-4193-9b9f-48f5133ea2c7
compressionor changeinthickness ( DT)ofthe joint. At this pointweassume thatthepreloadwill beequal to the clamping force. These two plots are shown at the top of this illustration. We then combine those two plots, as shown at the bottom of this illustration, to start constructing what we’ll call a joint diagram.Bickfor...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
159
b1dab1a5-84df-4ac1-8635-5d77f7e07e4a
Has this really created 9,600 lbs of clamping force between joint members? Our joint diagram assumes it has, but the correct answer is ‘‘probably not’’—at least as far as this first bolt is concerned. Remember that we had to tap some of those bolts into their holes? This implies that there was contact between the sides...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
160
ed41ecab-0629-4833-aba9-6a6f3c3a8d1e
process. 6.3 BOLT PRELOAD VERSUS CLAMPING FORCE ON THE JOINT The main purpose of the bolts is to clamp the joint members together. A common miscon- ception is that there is always an equal and opposite action–reaction relationship between the tension in the bolts in a joint and the thing we’re interested in, the clampi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
160
1e41258c-3c5e-4cf0-82fd-5c12358811ba
nut. Our goal is to clamp the joint members together. The hole in the upper joint member is undersized, so the stud is a press fit in this member. Thanks to frictional and embedment constraints between the sides of the bolt and the walls of the hole, it will take some positive force to pull the bolt through the hole, a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
160
f8b2991c-f1d0-4cae-addb-c6afe9dc80a4
The force is created, obviously, when we turn the nut, creating tension in the bolt. Thanks to hole interference, some of this tension will not end up as clamping force between joint members. Part of it will be lost as the bolt fights its way past the walls of the hole. I’m sure you can envision the extreme case in whi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
161
4120b739-544c-4b99-819d-cd87d03cc5dd
Hole interference is used on purpose by the airframe industry, for example, to reduce the possibility offatiguefailureof the shear-loadedjoints used inairframestructures.(Compressive stress built up in the walls of the bolt holes fights the formation or growth of fatigue cracks.) The holes are purposely drilled smaller...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
161
06d5bbf1-6d85-46cd-b45b-2971e42731e1
One airframe manufacturer recently measured the amount of force required to pull bolts of a given nominal diameter through holes drilled in plates of varying thickness. Some of the results are shown in Figures 6.7 and 6.8. The bolt and hole diameters used in the experiment varied through the full range of the manufactu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
161
6969c9a1-d375-4438-b221-b83d7253f8f1
0.5 1.0 1.5 2.0 2.5 3.0 Interference (in. /H11003 10−3)3.5 4.0 4.5 5.0 5.5 6.0 6.5Interference versus insertion force 2024 AL plate, WQ fastener516 = Plate34= Plate12+= Plate14 FIGURE 6.7 Chart showing the force required to push,5=16in. fasteners through interference fit holes in aluminum plates varyin...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
161
b82e6987-c778-45c1-b0c8-55ac586dafe9
counted on to pull all of the bolts through their holes, much less go on to develop any clamping force between joint members. In spite of this, the same torque is specified by the airframe manufacturer for all bolts of a given diameter, without regard to the amount of hole interference seen by a given bolt or the thick...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
162
4e09f2c8-0f6d-4cab-80e7-72fbaf693e1f
Another factor which can rob from the clamping force between joint members is shown in Figure 6.9. A heavy cover is being lifted up against a flange on a pressure vessel. As shown in the figure, the joint members have not yet been brought into contact, but we are turning the nut on the stud to bring them into contact. ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
162
3123d47c-28ce-4a37-baca-72a93e2cea40
Eventually the two joint members will be brought into contact. Further torque, at this point, will be required to create a clamping force between joint members to load the gasket. That torque should presumably be added to the torque required to pull the joint members together in the first place, but it rarely is in pra...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
162
dbc665a3-db8e-467a-8c71-74fca73d8e88
to thrust5=16in. fasteners through interference fit holes in aluminum plates of various thickness, summarizing some of the data shown in Figure 6.7. The three bars on the left side of the chart show the nominal preload which would be generated by5=16in. bolts if tightened to 50% of yield. Three bolt materials are shown...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
162
ca854b3e-f28c-49f6-9b75-fdc4d890a4a5
such situations. We learned of one situation in which large windmills are lowered to a horizontal position so that new, heavy blades could be attached. And these blades were raised by tightening the bolts, which fastened them to the structure. Although this kind of thing is rare, it is fairly common for large joint mem...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
163
3627770d-a724-4398-bd31-601356a68175
can’t. I have never seen anything in the literature on this subject either. Yet I’m convinced that this factor can seriously degrade the relationship between tension in the bolts and clamping force between joint members, especially in large joints, as one example. Warped or nonflat (e.g., wavy) joint members, incidenta...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
163
9efcfa66-40d0-4d8b-b28a-faa41888f4f6
etical calculations and conducted experiments to determine the forces, stresses, and moments in pipes and flanges when the flanges are misaligned. They used a hydraulic tensioner, for example (see Chapter 9), to measure the force required to pull misaligned flanges together, as shown in Figure 6.10. The chart in Figure...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
163
bac11395-504a-4332-ba01-0561f3a5e5b2
hanger or intersection with a larger pipe).Vessel Cover WeightGasket FIGURE 6.9 Heavy and misaligned or warped joint members can also affect the relationship between the torque applied to the fastener, the tension in the fastener, and the clamping force between joint members.Bickford/Introduction to the Design and Beha...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
163
4f1a16f2-08bb-4078-b0a2-892a44238241
As a result of these studies, Puget Sound developed some flange parallelism criteria, designed, as I understand it, to keep pipe stress below 3 ksi near any flange which is connected to turbines or other rotating equipment. Pipe stresses beside flanges located 50 or more pipe diameters away from rotating equipment were...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
164
08efbbc1-9b37-4569-9141-626079aa5210
function of the size of the ‘‘gap’’ shown here. 0.025 /H11033 0.020 /H11033 0.015 /H11033 1051015 2345 Pipe size (in.)Adjacent pipe stress (ksi) 678 FIGURE 6.11 A plot of the stress in the pipe adjacent to a misaligned flange versus the nominal diameter of the pipe, for misalignment gaps of 0.015, 0.020, and 0.025 in. ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
164
fdf8d408-6a18-48e5-b49e-37721cf4ec7e
6.4 CONTINUING THE SNUGGING PASS We’re now going to continue tightening the 16-bolt gasketed, flange joint we’re taking as an example in this chapter. We apply the snugging torque of 225 lb-ft to each of those bolts,following the cross-bolting pattern shown in Figure 6.2. We measure the preload, turn, anddeflection in ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
165
cdbdb9a6-6631-43b1-9e40-08affcd045fd
surfaces. Everyone’s happy, so we now go out and have lunch. When we come back from lunch we find our boss’s boss on the job site, reviewing our data. He wants to see how we managed to measure the tension or preload in these bolts, so weplug in our ultrasonic instrument and remeasure the preload in bolt number one, the...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
165
35a63fff-d846-4ee5-bddf-96b1f5f77639
which some people call ‘‘torque loss.’’ Here’s what he says. 6.5 SHORT-TERM RELAXATION OF INDIVIDUAL BOLTS Whether or not there’s a one-to-one relationship between bolt tension and interface clampingforce, there will often be some initial loss of tension in individual bolts after they are initiallytightened. Let’s call...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
165
c939bdfc-013b-4c6a-ac7e-1e196f1f574a
6.5.1 S OURCES OF SHORT-TERMRELAXATION Here are some things which can cause relatively short-term relaxation, starting with the mostcommon of all—embedment. The surfaces of the threads in the nut, the bolt, and the faying surfaces of the structural members, washers, etc. are never perfectly flat, even if such parts are...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
165
7e5ae4ab-a6a0-4555-a212-0e17534b94fc
Since initial contact areas are relatively small, the metal at the contact points cannot stand the pressures. Plastic deformation occurs until enough of the total thread surface has beenbrought into play to stabilize the situation and support the load without further deformation. The same thing happens in the faying su...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
165
66541396-e7c2-4317-80c4-0de738fd40b6
Many of these surface high spots are smoothed away during the tightening process [1]—at least they will be if the fasteners are torqued. Hydraulic tensioners don’t load the active threads,or even the joint surfaces underneath the nut or washer, until they let go off the bolt. As a result,there is often more embedment r...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
165
5c714c93-0c8c-4fb7-bb5f-0dc0e61a0963
Embedment is worse on new parts than on reused ones. In critical applications it can be minimized by tightening, loosening, and retightening the fasteners several times. This is done on camera mounts in space satellites, for example [2]. 6.5.1.1 Poor Thread Engagement If the bolt is undersized, or the nut oversized, th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
166
dbd035bc-d9e3-4b37-baeb-451051a9ea3b
6.5.1.2 Thread Engagement Too Short The length of thread engagement for steel fasteners should be at least 0.8 times the nominal diameter of the fastener. If the engagement length is too short (too few threads supportthe load), thread contact areas are again smaller than those intended by the fastenermanufacturer and e...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
166
7c4b2cdc-d544-4518-8d63-ea674f4211e2
into contact to stabilize the joint. The process is called embedment. FIGURE 6.13 Poor thread engagement may be a major source of plastic deformation and therefore joint relaxation.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 120 26.7.2007 1:37pm Compositor Name: VAmoudav...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
166
d4e85b41-cbd6-4890-9264-29efa91d79ba
6.5.1.3 Soft Parts If parts are softer than intended by the designer—perhaps because of improper heat treat or incorrect material—they may creep and relax substantially even if the geometry is correct andloads are normal. 6.5.1.4 Bending If the fastener is bent as it is tightened, it will see higher stresses along one ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
167
2bfad2ff-ed83-4583-af11-b2f483be5c5b
6.5.1.6 Fillets or Undersized Holes If the head-to-body fillet contacts the edge of the bolt hole as shown in Figure 6.14, the edge of the hole will break down under initial contact pressures. This may result in a complete loss of preload, since such effects are usually large compared to the amount by which the bolt wa...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
167
2b3d2779-dc74-4507-8325-3ca65ee1e711
increase relaxation appreciably [5]. 6.5.1.8 Conical Makeups Surface irregularities will exist on conical joint surfaces as well as flat ones. The effect on axial tension in the fastener, however, is magnified if the embedment occurs on conical surfaces. FIGURE 6.14 Oversized fillets and undersized holes may result in ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
167
d44c08fb-5ae6-48f9-85d3-7ff55bcb9595
A given amount of relaxation perpendicular to the surface may mean substantially greater relaxation in the axial direction, as suggested in Figure 6.16 and Equation 6.3. r¼e sinu(6:3) where e¼embedment relaxation perpendicular to the surface of a conical joint member (in., mm) r¼resulting relaxation parallel to the axi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
168
83729be2-b0bc-48c1-ac65-30b4bec7feaf
relaxation. Fastener centerline e r q FIGURE 6.16 Conical or tapered joints usually relax more than flat ones for reasons given in the text.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 122 26.7.2007 1:37pm Compositor Name: VAmoudavally 122 Introduction to the Design and B...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
168
1fc99705-f601-4446-9705-175fa5eac3a4
6.5.2.1 Bolt Length Long, thin bolts will relax by a smaller percentage than short, stubby ones. The total embed- ment relaxation or the like will be the same for a given initial preload, but that embedment will be a different percentage of the total length of the bolt and therefore will mean a different percentage los...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
169
6847ed68-c4b4-4ad8-ad1c-6e4fc3e301e7
embedment is to use Belleville washers, as also shown in Figure 6.17. These springs have a very flat rate, compared to the stiffness of either bolt or joint members. They will therefore determine (limit) the preload and clamping force in the system (see Figure 5.16). Because of their flat rate, a small deformation in t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
169
b9bc145b-2ba6-413c-b154-584b6d69dfde
now more high spots to embed and settle in together. Doubling the number of contact surfaces, for example, will almost double relaxation in many cases [6]. 6.5.2.4 Tightening Speed Creep and flow take time. Fasteners that are tightened very rapidly won’t have time to settle in together during the tightening process and...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
169
81b5150a-be2f-404e-b4bc-21aa3ad8a7e3
examined in Chapter 7. You tighten the fasteners with high-speed tools, but pause once or repeatedly to give the parts time to relax. Tightening bolts in a series of passes, rather than applying full torque on the first pass, allows time for relaxation. This procedure also pulls the joint together uniformly. For both o...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
170
c406d0e4-c2a9-49e8-8416-e5849be8228a
interactions between fasteners, discussed in Section 6.6 of this chapter, are almost certainly involved here as well. 6.5.2.6 Bent Joint Members If joint members are soft or warped or bent, tightening one fastener can cause relaxation (or additional stress) in other fasteners. This sort of ‘‘cross talk’’ between fasten...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
170
046c791b-0578-47fc-b249-0cf1a7a03c7c
some anticipated mean. In general, fasteners relax rapidly following initial tightening, then relax at a slower rate, following the pattern shown in Figure 6.18. The amount of relaxation varies greatly, depending on the condition of the parts, finishes, initial and local tension levels, fit of parts, and all of the oth...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
170
4a3f2a11-49e4-411c-ba6e-db765b6ca118
structural steel showed a loss of 2%–11% of preload immediately after tightening, followed by another 3.6% in the next 21 days, followed by another 2% in the next 11.4 years [5, p. 61].Bethlehem Steel reports that only 5% of the initial tension will be lost in structural bolts set byturn-of-nut techniques 5% over the t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
171
a16f964d-8d92-46f3-b03a-337f7a262d2b
variety of results on a variety of structural bolts, different types of bolt heads, different nuts, with and without washers, etc. [11]. As one example, an A325 bolt with a regular (not heavy)head, a flanged nut, and no washer relaxed 2.6% in the first minute after tightening (most ofthis in the first 15–20 s). It had ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
171
02f0dbfc-eadf-4345-aded-be9f7571a31d
in.-lb. This is not all embedment, as we’ll see in Section 6.6. Gasketed joints will relax substantially, whether the bolts are torqued or tensioned. This is especially true during preliminary passes, when loss of as much as 80%–100% of initial tensionis not at all uncommon for reasons to be discussed soon. Gaskets wil...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
171
4b6d90ac-eee9-44ef-8e39-10ffc39edc8d
6.5.4 T ORSIONAL RELAXATION We’ve been looking at preload or tension relaxation. This is of prime importance to us,because of the general importance of correct preload. We mustn’t forget, however, thattorsional stress is also built up in a fastener as it is tightened, and that this stress is alsosubject to varying amou...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
171
5b6a0e72-c043-4d46-b47e-87bb0efb8a7c
Figure 6.19 shows the tension and torsion relaxation we measured in an experiment with a 2 1=4–8/C212 B16 stud, which had been lubricated with moly. Torsion relaxed 50% when the wrench was removed; tension actually increased 1%–2% during this period. We have sub-sequently seen this phenomenon on many other types and si...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
171
d8ae3a1c-5c74-4fe0-9eb8-0f69e1df5256
the face of the nut. Sizable relaxation of tension, occurring as the torsional stress disappears, can, of course, mask this exchange of torsion for tension. Thus we’ve observed this exchange only on hardjoints. But it’s relatively easy to reproduce, and we think its common. Many bolts in large jointsmysteriously ‘‘grow...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
171
a01c1229-5f0c-4dbb-b4d2-829109a43488
A torque wrench appears to respond to torsional stress levels in the bolt as well as to preload levels. The torque required to restart a nut can be less than that required to tighten it in the firstplace,eveniftherehasbeennolossinpreloadinthemeantimeiftorsionalstresshasdisappearedor been reduced. Repeated‘‘torquerecove...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
171
54485fc3-4f9d-415c-a840-b316461c7c62
now relaxed to a stretch of only 0.001 in. We reapplied 150 lb-ft of torque, and the stretch returned to 0.0014 in. Incidentally, it took only 100 lb-ft to restart the nut. The bolt now relaxed again, was tightened again, relaxed some more, and so on, as shown in Figure 6.20. Final preload (stretch) was 33% greater tha...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
172
c8e77309-a030-43ac-9b6d-7efb72bbe9e3
applied repeatedly to this fastener, with a pause for relaxation between each pass. Final preload was 33% greater than that achieved on the first pass.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 126 26.7.2007 1:38pm Compositor Name: VAmoudavally 126 Introduction to the D...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
172
2b99d2c6-0020-4ea0-873a-5e44fe52ecab
even though we never applied more than the initial 150 lb-ft of torque. The final restarting torque was still only 87% of the rated torque. Many mechanics would conclude from this thatpreload was still 13% below the initial value. This possible interaction between torsional andtension stress further complicates the tas...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
173
c702e48d-e9a5-4d60-b710-740bed30225e
Let’s assume that we’re planning to tighten a circular, flanged joint that contains eight bolts. We’re going to use ganged hydraulic wrenches or hydraulic tensioners to tighten thesebolts two at a time. The bolts we tighten simultaneously, of course, will be opposite each other on the flange, 180 8apart. To explain the...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
173
1e7ff1a0-5c61-4e26-a013-185a98bdc7b8
The 20,000 lbs of force that these two bolts are creating on the joint partially compress the joint. We now go on to tighten bolts 3 and 4 located 90 8away from bolts 1 and 2. Again, our tools work magic for us and we create exactly 10,000 lbs of initial preload in bolts 3 and 4when they are tightened (Figure 6.22). We...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
173
e826c462-1ac2-4491-ae7b-91340c12f187
little as the joint is compressed by bolts 3 and 4. At this point in the process, therefore, bolts 1 and 2 have a slightly lower amount of preload in them than bolts 3 and 4—even though each of the four bolts started with the same FIGURE 6.21 A simulated model of a bolted joint, in which the joint members are represent...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
173
ce550dd5-8688-4e87-acba-32ffedf56260
initial tension of 10,000 lbs. When we now go on and tighten bolts 5 and 6 in a third step, bolts 3 and 4 will relax a little, and bolts 1 and 2 will relax further. Tightening bolts 7 and 8 to complete the assembly will create relaxation in each of the six bolts tightened earlier. The result is four different levels of...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
174
6483238b-26d9-4331-9454-8e2bae637cc7
gasketed joint with a spiral-wound, asbestos-filled gasket was tightened in three passes using a cross-bolting pattern and tightening one bolt located 180 8away from bolt 1. The third and fourth bolts tightened are halfway between bolts 1 and 2, etc. The difference between the ‘‘x’’s and solid line shows the loss of in...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
174
d1785097-e47a-4b88-8b24-6a70c798c7e1
horizontal axis show the location of the bolts, and the order in which they were tightened. The second bolt tightened, bolt 2, is located 180 8away from bolt l. The third and fourth bolts tightened are halfway between bolts 1 and 2, etc. The difference between the x’s and solid line shows the loss of initial preload in...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
174
23d2c8ed-7bc6-4bdf-95f2-f639c6e66f50
The isolated ‘‘x’’s show the initial change in length achieved in each bolt as it was tightened individually. This change in length, or stretch, is proportional to the tension in the bolt, as we saw in Chapter 5 (or will see at greater length in Chapter 9). The sawtooth line shows the pattern of residual preload (stret...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
175
5d9cace1-81a0-4306-9728-1fb251c646a9
in that bolt by the 100 ft-lb of torque. After all the bolts in the joint had been tightened, however, the tension in bolt 1 was remeasured, and it was found to have only about 1.5 mils of stretch. Bolt 3 started and ended about the same place. Bolt 6 started with about 2 mils, but lost all but 0.25 mil as the other bo...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
175
08d1a477-0c59-4f04-96c4-710f76f3f9e2
started to break up and become more erratic. Note, too, that at this point in the procedure the scatter between maximum and minimum residual tension in the bolts is nearly 20:1, ranging from less than 1 mil of stretch in the bolt tightened fourth to nearly 8 mils of stretch in the108 124 146 162 15 Order tightenedStret...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
175
fbe29f3f-0508-4732-a313-f2e217517577
eleventh bolt tightened, and this despite the fact that the scatter between maximum and minimum tensions created in individual bolts as they were first tightened is fairly normal. Inpass 1, for example, the scatter between applied torque and achieved initial preload wasroughly +30%, as anticipated for as-received steel...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
176
ae055916-5763-46c4-ad4b-8ab4de9202b3
The fact that we were using a torque wrench to tighten these bolts contributes somewhat to the initial bolt-to-bolt scatter in tension, of course. But the elastic interaction contributesfar more to the final scatter, and has nothing to do with the type of tool used. Figure 9.11, forexample, shows similar results obtain...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
176
b93139ee-da28-4f45-8252-e1c30a5a908a
be less significant in the gasketed joint because this joint has a ‘‘memory.’’ Its leak behavior depends as much upon the initial preload developed in its bolts as it does to the residualpreload. You’ll find a complete discussion of this in Volume 2 of this text. Is there any way to prevent or eliminate elastic interac...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
176
c10410e8-1abe-44ff-b8c5-9e99858982a5
single pass. One might, for example, apply 400 ft-lb of torque to bolts 1 and 2; 300 to bolts 3 and 4; 200 to bolts 5 and 6; and 100 to bolts 7 and 8. Bolts 1 and 2 relax three times; bolts 3 and4 relax twice; bolts 5 and 6 relax once; and all end up with the same amount of tension finallycreated in bolts 7 and 8. Seve...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
176
b5294f0d-4411-45c8-bffb-5de0a40d95a4
This is illustrated in Figure 6.26, which shows the results achieved in another experiment on the joint described in Figures 6.23 through 6.25. The bolts were tightened in three passes as before, but the final pattern of preload differs significantly from that shown in Figure 6.25. This time, in an experiment to reduce...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
176
55bcf5e1-e01e-4437-abb2-495d28dbefbb
way from the +30% often claimed for torque procedures in general. We’ve tried other torquing procedures to reduce final scatter. For example, we’ve tried making a final pass at 75% of final torque on the odd-numbered bolts only; tried using a largenumber of passes (15 or 20) at the final torque; tried making several pa...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
176
38f1f221-20c5-4d2a-80e2-f0325c2fc2db
what pattern or format is used. Scatter is reduced slowly as the number of passes increases. But scatter cannot be eliminated by any ‘‘torquing’’ procedure I know of. If ultrasonics or datum rods or load cells can be used to monitor results, a different torque can be applied to each bolt and scatter can then be reduced...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
177
cafb0ea6-cf1d-4945-b310-5b64ba4c2c35
tive engine heads, for example. The closer you can come to simultaneous tightening, the less elastic interaction effect you will get. For example, if you can tighten half the bolts in the joint simultaneously, you will see less interaction than if you tighten them individually or tighten one-quarter of them at a time. ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
177
b9ea3c83-b59d-4ba7-9d83-26053cf641b8
rather than a decrease in preload scatter, although both are sometimes required. We can now modify our joint diagram to show the loss in preload created by embedment and by the average elastic interaction effect, as in Figure 6.27. The dashed lines show the situation—bolt and joint forces and deflections—before relaxat...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
177
b1be5095-2810-48df-aba9-977ebf67e49d
scatter of only +2% or so, in large-diameter gasketed or ungasketed joints. (His tests involved flanges with diameters of 16 and 24 in.) Using a cross-bolting pattern, he first tightens the bolts to an arbitrary, experimental tension, which he monitors with strain gages or ultrasonics. During this pass he determines th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
177
cfccb15c-c444-44a0-bc84-397e852889b1
same torques and procedure used earlier. The solid line shows the change in pattern of residual tensions after a fourth and final pass in reverse order (the last bolt was tightened first).Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C006 Final Proof page 131 26.7.2007 1:38pm Compositor Name: V...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
177
67e30e3a-a1bb-4c4c-8f51-408b84894592
single, cross-bolting pass, determining the amount each is to be tightened by use of a matrix of interaction coefficients derived from the data taken during the experimental pass. Once again, tension and not torque is used to determine the initial preload developed in each bolt during this final pass. He believes that ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
178
73312587-9903-4b93-af02-5cfe19a3f713
He also reports that the elastic interactions in a given joint appear to be repeatable, and therefore predictable, which would suggest that the interaction coefficients would have to be determined only once for a given joint. Finally, he reports that the first bolt tightened in a cross pattern can be overloaded by up t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
178
86278225-41cd-40eb-b62e-df3be93f8a1a
amount of clamping force created on a multibolt joint when it’s tightened. We include a few things learned in earlier chapters or elsewhere; for example, the fact that some bolts will be bent slightly if tightened against nonparallel joint surfaces (as discussed in Chapter 2). We also include some minor factors not dis...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
178
7da1619f-1bbf-452f-a604-cabaac9e2e92
ment reduces the initial preload by an amount shown as A. The average loss in a group of bolts, caused by elastic interactions, is shown as loss B. We use the average loss instead of the individual loss because joint behavior will more likely be determined by average loss than by worse case. The final, average, residua...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
178
e3f5ec6c-2d3f-4c69-ba42-a6dec8d4a943
Apply input to bolting tool Torque on nut Which results in-Heat loss in tool Twist (torsion) of boltAxial force on boltHeat loss in threads and nut/joint interfaceBending moment on bolt (if surfaces not parallel)Elastic/plastic deformation of reaction and drive members Bending stress Initial clamping force on joint int...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
179
78c52325-8abe-4227-b654-d0bb7c3e149d
from joint members on bolts tightened earlierEmbedment and/or creep of gaskets, burrs, threads joint members reduces the “plastic reaction force” on all bolts with time Residual clamping force on joint interface Repeat all blocks after “torque on nut” above Working loads on the joint  Inertia  Pressure  Weight  Axi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
179
3418e681-2d18-4f19-97d6-7225c7205171
from assembly operations Which may be subsequently modified in service by Force on wrench handle  Hammer blow  Air or hydraulic pressure  Etc., creating In field maintenance operations-Resistance of joint members to being pulled into contact (if any) FIGURE 6.28 Block diagram showing most of the factors which affec...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
179
c808806f-b2c0-428d-a290-9b56fb13795f
Because of our interest in stored energy, we also list the many ways the input work we do on the nuts is absorbed by the bolts and joint members. The work .Heats the parts and tools .Enlarges interference fit holes .Bends and twists the bolts .Dilates the nuts (see Chapter 3) .Pulls the joint members together .Overcome...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
180
4659efa2-369b-4f4c-af5f-63ab3cb4ca55
as the parts embed and relax. We now realize why accurate control of the assembly process is so difficult. We would have to predict or control such unpredictable things as the friction forces between parts, theeffort required to pull the joint together, the amount of hole interference, and the elasticinteractions betwe...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
180
a9f5342f-cf38-4018-ab69-a6d7f4f01360
Regardless of the type of control we adopt, furthermore, there are a number of relatively simple things we can do to improve our chances of success during assembly operations. Infact, the things listed below can often make more improvement than the use of elaborate or expensive preload control equipment. As you can see...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
180
0cf024ec-6083-433f-af2f-1be9252bb1fc
3. Make sure the fasteners are in reasonable shape. Wire-brush the threads if they’re dirty and rusted. Use stainless steel bristles on alloy steel materials. Chase threads with a tapor die if they’re damaged. Or replace the bolts with new ones! 4. Use hardened washers between the turned element (nut or bolt head) and ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
180
dd58b0f4-a89c-4a62-b13b-67a5d69e0200
7. Hold wrenches perpendicular to the axes of the bolts. 8. Apply torque at a smooth and uniform rate. Avoid a stick-slip situation as you approach the final torque. If necessary, back the nut off a little so that the specifiedtorque can be reached with the wrench in motion. 9. If hydraulically powered wrenches are use...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
181
cb3bf040-bceb-41cb-be59-c166ca309e3e
rectangular (as in a structural steel joint). Work in a cross-bolting pattern on circularor oval joints. 12. Keep good records of the tools, operators, procedures, torques, and lubricants used. Bolting is an empirical ‘‘art’’ at present. If you record details of your ‘‘experiment’’you’ll have the information you need t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
181
8f4dbbd0-717e-4ada-8f67-b06ed9e7d335
an individual bolt? 3. Is the preload mentioned in question 2 above initial or residual preload? 4. What would be the result if we lubricated the bolts in a given joint for the first time and reduced the friction loss during tightening by 3%? 5. Why do individual bolts relax a bit when first tightened? 6. Name several ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
181
34321b08-5823-4e72-bb88-a8ce2f130aee
REFERENCES 1. Landt, R., Preload Loss and Vibration Loosening , SPS Technologies, Jenkintown, PA, 1979. 2. Conversation with Carl Osgood, Consultant, Cranbury, NJ, 1974. 3. Friesth, E.R., Performance characteristics of bolted joints in design and assembly, SME Technical Paper AD77-715, 1977. 4. High strength bolted joi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
181
e2a54c23-8d67-4272-b2dd-c3b8992bf206
8. Prodan, V.D., et al., More precise load-relief factor for tightened screw connections, Vest. Mashin. , vol. 54, no. 1, pp. 27–28, 1974. 9. Junker, G., Principles of the Calculation of High Duty Bolted Connections-Interpretation of Guideline VDI 2230 , VDI Berichte, no. 220, 1974, published as an Unbrako technical th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
182
159a482e-b0b8-40ea-8ca2-170dbd563672
January–February 1973. 13. Hardiman, R., Vibrational loosening-causes and cures, Presented at the Using Threaded Fasteners Seminar at the University of Wisconsin-Extension, Madison, May 8, 1978. 14. Investigation of threaded fastener structural integrity, Report prepared by Southwest Research Institute, San Antonio, Te...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
182
76d43749-1f47-4807-9dc5-ac73950a7b2b
applicable to high-pressure apparatus, Khimicheskoe i Neftyanoe Mashinostroenie , no. 2, pp. 3–5, February 1973. 18. Tripp, Owen S., and Earl D. Stevens, Flange parallelism criteria, presented to the PVRC Subcom- mittee on Bolted Flanged Connections, San Francisco, CA, January 1983. 19. Bibel, G. and R. Ezell, An impro...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
182
d3e2f824-a06a-4e17-8528-4ac1298ef71f
and elastic interaction effects, Fastener Technology International , February 17, 1994. 22. Bibel, G., ‘‘Tightening groups of fasteners in a structure and the resulting elastic interaction,’’ in Handbook of Bolts and Bolted Joints , John H. Bickford and Sayed Nassar (Eds.), Marcel Dekker, NY, 1998.Bickford/Introduction...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
182
e82f658b-29b0-4814-9171-9331f29c068c
7Torque Control of Preload We have now reviewed the assembly process and have seen why the control of that all-important clamping force on the joint is so difficult. During this review we assumedthat we were using the torque applied to the nut to control the tension or preload built-upwithin the bolt. Now we’re going t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
183
119c3773-4424-4f66-983e-050590935593
as a means of evaluating the residual preload in a bolt. In later chapters we’ll study other means of controlling assembly preloads. But make no mistake: at this point in time, torque is king. It’s by far the best-known, most common, andusually the least expensive way to control preload. It doesn’t do a perfect job, bu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
183
eac49680-6640-48c1-80fd-3b0d6b627c60
the other. During initial assembly of an individual bolt there’s a one-to-one relationship between the tension in a bolt and its preload. As we saw in the last chapter, however, the tensile load in a bolt will change as we tighten other bolts or put the joint in service, so the preload is an initialand short-lived affa...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
183
12a754d9-20ff-45a7-9274-75b8d1383eed
all bolts have been tightened. The tension in a bolt in service : We’re most interested in the last one on this list, the tension in the bolts while they’re in service, but in this and the next two chapters we’re going tofocus on the initial preload we get when we first tighten a bolt. This is the preload overwhich we ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
183
1f40b53c-4704-4e89-b9e7-05ae4ccdf477
7.1.1 P ROBLEMS CREATED BY INCORRECT PRELOAD We’ll take a closer look at these points in later chapters, but here’s an introduction to the problems created by incorrect preload. 1.Static failure of the fastener : If you apply too much preload, the body of the bolt will break or the threads will strip. 2.Static failure ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
184
5bc75587-6501-4c7b-a5c1-f578dbf4e837
5.Stress corrosion cracking : Stress corrosion cracking (SCC), like fatigue, can cause a bolt to break. Stresses in the bolt, created primarily by preload, will encourage SCC ifthey’re above a certain threshold level, as we’ll see in Chapter 16. 6.Joint separation : Proper preload prevents joint separation; this means ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
184
a9631bbe-9dcd-4f56-bb78-12a49667413a
8.Excessive weight : If we could always count on correct preload, we could use fewer and smaller fasteners, and often smaller joint members. This can have a significant effect on the weight of our products. 9.Excessive cost : The cost of many products is proportional to the number of assembly operations. Correct preloa...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
184
f4da1d14-dbf1-4b35-9f05-e9ff73ee9a58
7.1.2 H OWMUCHPRELOAD ? We always want the maximum possible preload, but in choosing this, we must consider: .Strength of the bolt and of the joint members under static and dynamic loads .Accuracy with which we expect to tighten the bolts .Importance of the joint, i.e., the factor of safety required .Operating environm...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
184