id stringlengths 36 36 | text stringlengths 1 1k | source stringlengths 42 191 | page int64 0 1.03k |
|---|---|---|---|
8dacc189-7285-4e5c-acab-f99f65a49987 | Behavior of the Joint Loaded in Tension: A Closer Look 275 | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 321 |
b5075d3d-c8ad-4715-8214-e172596f3ae6 | of the tools used in proximity to hot parts, etc. But a lubricant analysis should be a reasonable
way to get a rough estimate.
Beyond that, keep track of the torques used (and the temperatures involved). Experience
will show you whether those torques were ‘‘good’’ or ‘‘bad’’ for the next shutdown or repair.
11.5 JOINT ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 322 |
76afe8b3-927f-4717-a2a4-7cff0257dde4 | Remember, too, that the sign of the differential expansion force is not always the same. If
the joint expands more than the bolts, it’s positive; if the bolts expand more than the joint,however, there will be a loss of both clamping force and bolt tension, and the sign will benegative. With all that in mind, let’s rewr... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 322 |
19fb8c7f-ee92-4296-848b-127898bcd02b | In the three equations above,
FPa¼the average or target assembly preload (lb, N)
DFm¼the change in preload created by embedment relaxation (lb, N); Equation 10.5
showed us that DFm¼emFPa
em¼percentage of average, initial preload ( FPa) lost as a result of embedment, expressed
as a decimal
DFEI¼the reduction in average,... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 322 |
e9eb8f3f-8346-4f5c-a857-ccd342de9503 | same Dt(in., mm); see Equation 11.15
s ¼half the anticipated scatter in preload during assembly, expressed as a decimal
fraction of the average preload; see Equation 10.1
K00
J¼the stiffness of a joint in which both the axes of the bolts and the line of applicationof a tensile force are offset from the axis of gyration... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 322 |
93974ebb-d0bc-422d-93b8-6cdc8a985ca3 | tensile load is applied along loading planes located within the joint members (lb =in.,
N=mm); K0
Jis the reciprocal of the resilience of such a joint (see Figure 11.16)
Fen¼the load factor for the joint whose stiffness is K0
J(see Figure 11.16)
N ¼number of bolts in the joint
Again, these equations can be rewritten us... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 323 |
88169c28-2884-4439-b633-53ce87c8c681 | Assembly parameters:
s¼tool scatter ¼0.30
e
m¼0.1
eEI¼0.18
FPa¼target preload ¼50% of bolt yield
Service conditions:
Operating temperature ¼4008F
External load, LX¼0.25FPa
n¼decimal defining distance between loading planes ¼0.5
The joint: dimensions and properties (see Figures 5.11 and 11.12)
Material: mild steel
E¼27.... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 323 |
85770b18-9edb-43c4-88ec-81773b265a8b | AS¼tensile stress area of the threads ¼0.0775 in.2(Appendix F)
E¼30/C2106psi at 400 8F
KB¼2.124 /C2106lb=in., as computed in Section 5.2
Sy¼yield strength at 70 8F¼37/C2103psi
DB¼width across flats of the head of the bolt ¼0.5 in.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C011 Final Proof pa... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 323 |
e3aa8b1f-85eb-42ea-946d-d24b9a8effb9 | DH¼0.4 in.
rB¼coefficient of expansion ¼9.35/C210/C06in.=in.=8F
Now, using the data listed above, we need to compute several factors required for
Equations 11.21 through 11.23. First let’s compute the area of the joint ( AJ) and of the
equivalent cylinder of the joint ( AC). See Figures 5.10 and 5.11 for reference.
AJ¼... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 324 |
0214e729-8827-498f-a175-a78b9ec1c2f6 | (refer Figure 5.10).
rJ¼1=KJC¼0:328/C210/C06in:=lb
Next we need the factor l2(refer Figure 11.15)
l2¼s2AC
R2
GAJ¼0:22(0:11)
0:0437 (0:75)¼0:134
Now we can compute resiliencies r0
J,r00J,rB(reference Figure 11.15) and joint stiffness K00
J
r0
J¼rJ1þl2/C0/C1
¼0:328/C210/C06(1þ0:134)¼0:372/C210/C06in:=lb
r00J¼rJ1þal2
s/C1... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 324 |
fa4c5d3c-83bc-43c6-a59b-b0c2ee134e4a | DLJ¼rJ(LG)Dt¼8:3/C210/C06(1:0)330¼0:00274 in:
DLB¼rB(LG)Dt¼9:35/C210/C06(1:0)330¼0:00309 in:
Finally, let’s select an assembly preload, which becomes our target or average preload
(FPa). We said that we wanted FPato equal 50% of the bolt’s yield strength. That will be the
room temperature yield strength because assembl... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 325 |
8e555bdb-3583-4571-b31e-3da5e3d2af16 | Max assembly preload ¼(1þs)F
Pa¼(1þ0:3)1:43/C2103¼1:86/C2103lbs
Embedment loss ¼em¼FPa¼0:1(1:43/C2103)¼0:143/C2103lbs
Average elastic interaction loss ¼eEIFPa¼0:18(1:43/C2103)¼0:257/C2103lbs
Increase in bolt tension caused by the external load ¼FenLX¼Fen(FPa=4)¼0:247
(1:43/C2103=4)¼0:0883 /C2103lbs
Decrease in bolt ten... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 325 |
bd3a32da-4b58-4923-93cb-c44088aff901 | Now for minimum clamp force (Equation 11.22)Minimum assembly preload ¼(1/C0s)F
Pa¼0:70(1:43/C2103)¼1:00/C2103lbs
Embedment and elastic interaction losses are the same as computed above.
Loss in clamp created by the external load ¼(1/C0Fen)LX¼(1/C0Fen)(FP=4)¼(1/C00:247)
(1:43=4)103¼0:269/C2103lbs.
Loss in clamp caused b... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 325 |
e1cf3333-71b4-446f-8648-a8fe287b7e8c | Ratio ¼Max F P
Min per-bolt FJ¼1:86
0:123¼15:1Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C011 Final Proof page 279 26.7.2007 1:18pm Compositor Name: VAmoudavally
Behavior of the Joint Loaded in Tension: A Closer Look 279 | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 325 |
7046dad5-3e7b-4f98-b7f6-57fbb5a3a8cf | Once again we see that inability to control assembly preload, elastic interactions, and
embedment, plus the effects of external loads and differential expansion have forced a
significant overdesign of the joint. We could improve results by using bolt and joint materials
having similar coefficients of expansion or by us... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 326 |
28db57b8-d726-42db-bdc8-e34b69ecb130 | will be exposed to those effects. But will each joint see a full +30% scatter in the torque–
preload relationship? I very much doubt it. If we had placed this joint in production we could
assume that an occasional joint would see a full þ30% or a full /C030%; but I would suspect
never both. Also, if this joint was to b... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 326 |
4f0776ae-edc2-4ef1-b00d-9d1efe4453dd | used if our bolts are new and as-received (unlubed) but were all obtained at the same time
from the same source; and perhaps +5% for new, single-source, lubed bolts. Higher figures
would, of course, be used for old, reused bolts, especially if they show signs of handling or
are slightly rusty or something. For design p... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 326 |
0c162eed-bd79-4471-bf54-ef14100e3a07 | interactions (EI), differential expansion (th), and external tensile load on the joint. The resulting
maximum bolt load, which will define the size of the bolts, is 15 times the minimum per-bolt clamping
force we can count on from those bolts.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C011 F... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 326 |
748b859a-2e4a-4cf9-9be1-c35d46294a30 | EXERCISES AND PROBLEMS
1. Define prying action.
2. Sketch an alternative joint diagram showing the effects of prying action.3. Name at least two things the joint designer can do to reduce prying action.4. This and the following three questions are all in reference to a ductile iron joint whose
width ( D
J)¼1.625 in. Th... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 327 |
fba87f37-1f55-456e-9011-7a275c5be9aa | external load?
9. Now consider a second joint of the same material, width and thickness as the joint in
problem 4 above but eccentrically loaded. This time, however, the line of action of theexternal load is 0.563 in. removed from the centerline of the joint and the bolts are 0.2 in.removed from that centerline (i.e., ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 327 |
2e6a67ba-a3fa-49b3-ac39-ade5259e87be | reduce the clamping force on this joint?
13. What is the minimum preload required to prevent separation of this eccentric joint?14. The concentric joint of problem 4 is subjected to an increase in temperature of 100 8F.
Does this increase or decrease the tension in the bolts? By how much? (Assume that thecoefficient of... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 327 |
6d9b1ae2-d461-4524-9b12-06cfc86aac6b | February 1974.
3. Agerskov, H., Analysis of bolted connections subject to prying, Journal of the Structural Division ,
ASCE , vol. 103, no. ST11, November 1977.
4. Simon, M.W. and J.B. Hengehold, Finite element analysis of prying action in bolted joints, Paper
no. 770545, Society of Automotive Engineers, Earth Moving I... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 327 |
3df22785-41ee-4196-b5c0-364395392b06 | SAE, Warrendale, PA, February 25–29, 1980.
7. Grotewohl, A., Calculation of a Dynamically and Eccentrically Loaded Bolted Connecting Rod
Connection according to VDI 2230 , VDI Berichte no. 220, 1974.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C011 Final Proof page 281 26.7.2007 1:18pm Composi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 327 |
5fd8e6e8-ba77-42f4-ba09-ae0e337d1407 | 8. Pindera, J.T. and Y. Sze, Response to loads of flat faced flanged connections and reliability of some
design methods, University of Waterloo, Canada, CSME Transactions , March 1972.
9. Pindera, J.T. and Y. Sze, Influence of the bolt system on the response of the face-to-face flanged
connections, Reprints of the 2nd ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 328 |
01634e4f-6510-4825-9f39-17b41623b9ff | Research Report of the Industrial Fastener Institute, Cleveland, OH, April 4, 1986.
12. Halsey, N., J.R. Gieske, and L. Mordfin, Stress relaxation in aeronautical fasteners, National
Bureau of Standards Report no. NBS-9485, February 1967.
13. Markovets, M.P., Graphic analytic method of calculating the time to failure o... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 328 |
02789141-5ea8-4a4e-a0be-818a60e8e387 | 16. Criteria for design of elevated temperature Class 1 components in Section III, Division 1, of the
ASME Boiler and Pressure Vessel Code, ASME, New York, May 1976.
17. Kraus, H. and W. Rosenkrans, Creep of bolted flanged connections, Welding Research Council
Bulletin , no. 294, Welding Research Council, New York, May... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 328 |
01b68a89-5d4d-4459-a884-a4f281b9b9f3 | no. 363 (May 1991), no. 365 (July 1991), and no. 366 (August 1991).
21. Grosse, I.R. and L.D. Mitchell, Nonlinear axial stiffness characteristics of axisymmetric bolted
joint, available from the University of Massachusetts, Amherst, MA, or from the Virginia Poly-technic Institute and State University, Blacksburg, VA, 1... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 328 |
b2178e6d-5c68-40d1-b413-18f60f4967af | 12In-Service Behavior
of a Shear Joint
We’ve studied axial tension loads at length because they’re always present (since we preload—
tension—the bolts as we tighten them) and because they will often dominate the behavior ofthe joint even when other types of load are also present. Tension loads in general are also themo... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 329 |
52df9754-8418-4580-af7f-073be39b9119 | Design Criteria for Bolted and Riveted Joints [1,2], which I recommend.
Although we can’t examine them at length, it’s pertinent for us to take a brief look at shear
joints—enough to see why they’re different, and enough to know when to read another book!
12.1 BOLTED JOINTS LOADED IN AXIAL SHEAR
In a shear joint, the e... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 329 |
5975f148-93cb-446f-8cf7-69336e1da6c2 | runs through the centroid of the group of bolts, it’s called an axial shear load, as shown inFigure 12.2.
The strength of such a joint depends on (1) the friction developed between the joint
surfaces (called faying surfaces) and (2) the shearing strength of the bolts and plates. Untilrecently, joints loaded in shear we... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 329 |
05013c5a-5f4d-4b0f-b276-7ce606d62dd3 | field joints.
We’ll look at the field situation a little later, and at contemporary shear joint classifica-
tions. First, though, I think that the original definitions are still a useful place to start learningabout the design and behavior of shear joints. I also think that, although pure friction orbearing joints may ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 329 |
a664676b-da1e-42c8-9037-e1ae984d680b | possible in nonstructural applications, the main requirement being the ability to control joint
and hole geometry more closely than is possible in structural steel applications. So, let’s start
our review by looking at the classical friction-type and bearing-type joints. Then we’ll return
to the present structural stee... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 330 |
40ea7d97-6ad5-434e-b6e8-cef2867c20e6 | force clamping the two parts together, and to the coefficient of friction at the interface. In a
joint, the normal force is produced by the preload (axial tension load) in one or more bolts.
The total friction force developed in the joint is called the ‘‘slip resistance’’ of the joint (RS).
In Chapter 19 we’ll see how ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 330 |
56932a52-c49c-44af-ac87-f1c093f78e7b | these conditions, the bolt is loaded by the pure axial tension created when the nuts were
tightened. In other words, we’re back to the original joint diagram—with zero external loads
(Figure 12.4).
The elastic curve for the bolt will be that of a bolt under axial tension load—for example,
the curve shown in Figure 3.1—... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 330 |
4fdf121c-d0e3-4ac6-85e0-fd16a3fdacdb | The specifications recommend that the bolts in structural joints be set to a tension at least
equal to the proof load of the bolt—i.e., approximately equal to the yield strength of the bolt.
This is the minimum setting recommended. Through use of turn-of-nut procedures (described
in Chapter 8), or tension-indicating fa... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 331 |
0081d853-163b-40de-96d2-efa94d436cbe | As long as the joint doesn’t slip, the tension in one set of plates is transferred to the others as if
the joint were cut from a solid block. Lines of principal (tension) stress flow from one to the
other without interruption (neglecting for the moment the local stress concentrations caused
by the holes or by the clamp... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 331 |
8de22c83-7e2c-4b1d-94c4-23aa933df6f0 | It’s worth noting that the ultimate strength of all shear joints is determined by their
strength in bearing—not by their frictional slip resistance. Friction-type joints, however, are
often considered to have failed if they slip into bearing. Ultimate strength is rarely a good
measure of the design strength or useful s... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 331 |
bf5e6596-885d-403e-b25c-e0591e3706e2 | 12.1.3.1 Stresses in Bearing-Type Joints
The stress patterns in bearing-type joints are more complex than those in friction-type joints.
The tension in one set of plates is transmitted to the others in concentrated bundles throughthe bolts (Figure 12.7). What’s more, each row of bolts transmits a different amount of lo... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 332 |
93001678-81ff-4ab0-a9a0-db42e293e831 | As a result, the outer bolts in a joint see far more than the average stress level—some say
as much as five times the average—while the inner ones see less than average. The outer bolts,therefore, usually are loaded plastically rather than elastically. This results in plastic flow,
which helps to distribute the load mo... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 332 |
7dbc2425-843a-4a1e-9a3d-7f6ed1a3d66c | As far as bolt preload and clamping force are concerned, shear joints are affected by all of thefactors which affect those things in tensile joints.
Initial preloads will be scattered as a result of variations in geometry, lubricity, condition,
etc. of the parts involved, as well as variations in tools, operators, proc... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 332 |
5b1738e0-1f6f-4e76-8b9c-2b02fe959e3c | The bolts and joint members embed in shear joints, just as they do in tensile joints.
‘‘Elastic interactions’’ occur as a group of bolts are tightened in a shear joint.
Preloads and clamping forces in a shear joint will be altered by differential expansion if
the parts are made of different materials or are subjected t... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 333 |
219eb05d-c7df-4398-bae7-c28773784d76 | differential expansion.
We can draw a joint diagram for such a joint. It would look exactly like the diagram of
Figure 11.28 but without the external load effect shown at the bottom of that diagram. The
minimum, residual clamping force on the joint in that diagram, Min per-bolt FJ, will be the
clamp left after differen... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 333 |
0b813700-94b6-490a-b7e5-97c72c8fcfad | Figure 12.5).
1 2 3 4 5 6 7 8 9
1Shear
stress
23456789
FIGURE 12.8 Shear stress in individual bolts varies substantially, especially in long joints. (Modified
from Fisher, J.W. and Struik J.H.A., Guide to Design Criteria for Bolted and Riveted Joints , Wiley,
New York, 1974.)Bickford/Introduction to the Design and Beha... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 333 |
fdebbb6a-fdd3-4369-9a5c-e898a7029884 | 12.3 RESPONSE OF SHEAR JOINTS TO EXTERNAL LOADS
Figure 12.9 diagrams the way in which a shear joint responds to ever-increasing loads. The
figure shows the overall deformation and displacement of joint members as a function of
applied shear force. To start with (part 1 of Figure 12.9) there is linear, elastic deformati... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 334 |
69bba294-8ed6-45ab-81a3-76f1867bf760 | members are free to pull past each other, or the bolts tear out through the sides of the
joint members.
Clamping forces and bolt stress are changed when shear loads are applied to the joint.
Once the bolts have been brought into bearing, shear stress combines with the original tensile
stresses created when we tightened... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 334 |
64e14bb8-bbe0-41c6-8bf7-1ac6ac575824 | how they were originally preloaded [2, p. 49].
None of this, however, can be usefully shown in a joint diagram. The diagram of
Figure 10.4 still stands as our best representation of a joint loaded only in shear.
12.4 JOINTS LOADED IN BOTH SHEAR AND TENSION
There are joints that must support both shear and tensile loads... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 334 |
71e5ca78-113f-4ef4-9951-f7c1c85dc570 | The tendency of the joint to slip into bearing can be based on the resulting Min per-bolt Fs.12
34
5
DeformationForce
FIGURE 12.9 This chart illustrates the sequence by which a shear joint fails. See text for a discussion.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C012 Final Proof page 288 2... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 334 |
d443473b-a79b-4672-8ce8-36df88977a11 | The following equation can be used to determine how much shear stress the bolt can stand
if subjected to a given tensile stress, or vice versa [1, p. 69; 3, p. 14; 2, p. 51].
S2
T
G2þT2
T (12:1)
where
ST¼the ratio of shear stress in the shear plane(s) of the bolt to the ultimate tensile strength
of the bolt
TT¼the rati... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 335 |
45f5575f-e533-4273-9dde-46ad9f191265 | BD bolts. Similar curves can also be drawn for dynamic loads.
Note that Equation 11.1 does not compute the allowable stress limits for a given bolt. It
merely shows the relationship between tensile and shear stresses. However, a number of
authors have plotted and published solutions of the equation for stress levels th... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 335 |
5e0d8bb7-47d2-4003-ae88-9af940c64646 | loads on the thread stress area of ASTM A325 or A354 BD bolts. (Modified from Fisher, J.W. and
Struik, J.H.A., Guide to Design Criteria for Bolted and Riveted Joints , Wiley, New York, 1974.)Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C012 Final Proof page 289 26.7.2007 1:16pm Compositor Name... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 335 |
768d8003-d216-4e45-8884-1940f091708c | shear planes will pass through the shank of the bolt, others assume that shear planes will pass
through the threads, etc.
12.5 PRESENT DEFINITIONS—TYPES OF SHEAR JOINT
To this point in this chapter we’ve been using the descriptive but old-fashioned terms friction-type and bearing-type to analyze and discuss joints load... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 336 |
b71c7e74-a509-47a3-91c5-31d2165fa509 | 3. Slip-critical joints: those which resist shear loads with faying surface friction. They
would obviously be analyzed as friction-type joints.
Snug-tightened joints are only used where slip will not affect the serviceability of the structure.They are not allowed for applications involving A490 bolts. Such joints may b... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 336 |
d2ad9fc4-c622-4691-a4d1-2360e64d236d | will be subjected to varying tensile loads.
Pretensioned joints are required if called for by local code or spec, or if the joint will see
significant load reversals. They are also required if the joint would be subjected to nonrever-sing fatigue loads, or if the A325 or F1852 bolts are subjected to fatigue loads or if... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 336 |
cfb16767-34cf-4c50-8eaf-3a2173260bd3 | Slip-critical joints are required when slip could affect the serviceability, strength, perform-
ance, or stability of a structure, and when a joint will be subjected to load reversals andfatigue loads. They’re also required if a joint member has oversized or slotted bolt holes,unless the line of action of a shear load ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 336 |
75aa0112-e235-49fd-b689-579e05a88ea5 | 8. Should a slip-critical joint be analyzed as a friction-type or bearing-type joint?9. Describe some of the applications in which slip-critical joints are mandated.
10. What is the difference between a pretensioned and a slip-critical joint?11. Under what conditions is it acceptable to only snug-tighten the bolts in a... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 336 |
756439b3-5750-4c66-b1f9-f88afdfd5905 | REFERENCES
1. Fisher, J.W. and J.H.A. Struik, Guide to Design Criteria for Bolted and Riveted Joints , Wiley, New
York, 1974.
2. Kulak, G.L., J.W. Fisher, and J.H.A. Struik, Guide to Design Criteria for Bolted and Riveted Joints ,
2nd ed., Wiley, New York, 1987.
3.High Strength Bolting for Structural Joints , Booklet 2... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 337 |
a895064c-1c9c-44ca-b446-dd21c8973168 | Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C012 Final Proof page 292 26.7.2007 1:16pm Compositor Name: VAmoudavally | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 338 |
5bec6bf7-bb7e-4c7a-98c2-939730b16689 | 13Introduction to Joint Failure
One of our main goals in studying the design and behavior of bolted joints is to avoid joint
failure by proper design and through the use of effective assembly techniques. Now that wehave studied in some detail the assembly process and the effects of external loads on the joint,we are re... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 339 |
f99c6139-9bd4-4a8a-b243-a84b69bcd26a | More commonly, as we will see, joint failure will occur if the bolts provide too little
clamping force. In most such situations, the clamping force will probably be insufficientbecause of deficiencies in the assembly process. Remember that most of the factors includedin the block diagram of Figure 6.28 would result in ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 339 |
94513684-cce1-4f20-8378-96fcde03d408 | We are going to start with an overview of the whole subject of joint failure, then go on to a
closer study of the four principal types of failure: self-loosening, fatigue, corrosion, andleakage. But first, lets examine some of the ways in which a joint or bolt can fail.
13.1 MECHANICAL FAILURE OF BOLTS
Obviously, bolts... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 339 |
1032999c-cad2-4737-b8eb-53a4ca0896a3 | .Mechanical failure at elevated temperatures (bolt strength dropped as temperaturerose)
.Corrosion ate through the bolt
.Stress corrosion cracking
.Fatigue failure
We will look at corrosion, stress corrosion cracking (SCC), and fatigue in Chapters 15 and 16.These are relatively common causes of bolt failure. Mechanical... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 339 |
44cffcc0-54c9-4ae6-b615-f1fce4577dde | the fact that manufacturers of low-cost bolts had been using boron steel instead of medium
carbon steel for Grade 8 fasteners, and boron steel loses strength more rapidly than carbonsteel does as the temperature is raised.
There were also been recent reports that heads had snapped off low-cost bolts when they
were tigh... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 340 |
6c9ef9cc-b29b-4212-885b-c652c22a3f1d | 13.2 MISSING BOLTS
It’s also obvious that bolts won’t perform their clamping function properly if they’re missing.
Perhaps the most common reason for missing bolts is a phenomenon called self-loosening,
which we will look at in detail in Chapter 14. Self-loosening is most commonly caused byvibration, but can also be ca... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 340 |
95b0754a-3d24-4ca8-9840-f17a54af3aca | misalignment or the like. In other cases, only carelessness was involved. Because most bolted
joints are grossly overdesigned, most of them can get by with a few missing bolts, butobviously, we don’t want to do this in critical situations.
13.3 LOOSE BOLTS
Bolts that aren’t tight enough, i.e., bolts improperly preloade... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 340 |
44952cda-3b4a-4990-b0b0-8fc9ec356fbe | The relationship between loose bolts and self-loosening is a chicken-and-egg proposition.
If the bolts are too loose to start with (were improperly tightened during assembly, forexample), this will encourage self-loosening. Self-loosening, on the other hand, will progres-sively loosen the bolts. It’s often difficult to... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 340 |
7aafcc6d-d8ac-436f-ba44-1674f170d6f5 | 13.4 BOLTS TOO TIGHT
It’s less obvious and less common, but bolts that are too tight can also contribute to joint
failure. Excessive bolt loads can crush gaskets, for example, or damage (gall) joint surfaces.
Excessive bolt loads can also encourage SCC, as we will see in Chapter 16, or can reduce
fatigue life, as we wi... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 341 |
3c04d8d6-3f40-4321-a63c-85f864428b46 | 13.5 WHICH FAILURE MODES MUST WE WORRY ABOUT?
Which failure modes must the bolting engineer worry about? The answer depends on the jobbeing performed by the bolted joints, on the consequences of failure, on the environment thebolts are working in, and usually on the industry. The petrochemical industry, for example, is... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 341 |
91a240e6-6faa-4c6f-a091-e2723242fabd | is sometimes an issue, but usually of joint members rather than of the bolts. Self-looseningand leakage are never encountered. The aerospace industry would probably list fatigue first.
13.6 CONCEPT OF ESSENTIAL CONDITIONS
I think it’s useful to recognize that each type of failure is set up by a limited number of‘‘essen... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 341 |
c77a9710-a51c-43c2-9d23-1339b7d86f72 | listed below.
SCC requires:
.A susceptible material
.Stress levels above a threshold
.An electrolyte
.An initial flaw
Hydrogen embrittlement requires the same conditions as SCC, but with hydrogen instead ofan electrolyte.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C013 Final Proof page 295 26... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 341 |
3955bff4-063e-4dc8-ad9b-7dfb7bd230a4 | Fatigue failure requires:
.Cyclic tensile stress
.A susceptible material
.Stress levels above an endurance limit
.An initial flaw
Mechanical failure requires:
.Stress levels exceeding the static strength of the bolts or threads
Self-loosening of the fastener requires:
.Cyclic loads at right angles to the bolt axis
.Rel... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 342 |
0bf14b9a-c716-41e0-87e2-9083671c121b | hundreds—of secondary conditions can establish the essential conditions required for aparticular type of failure. We’ll look at some of these secondary c onditions when we study
corrosion, fatigue, self-loosening, etc. in detail in subsequent chapters. To give you anexample of the diversity of secondary conditions, how... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 342 |
746fa317-8050-4000-8673-0635c776368c | Tabulations were made of the factors, which had contributed to the potential problems
reported. These factors are what I have called secondary conditions, above.
Remember that, earlier, we said that the only essential condition for mechanical failure
was stress levels exceeding static strength. A total of 170 safety-re... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 342 |
aba71afe-6d02-441b-9b11-4dfaed5288d4 | .Poor fastener dimensions (e.g., poor thread fit)
.Elevated temperatures
.Construction procedures
It’s easy to think of additional things which might cause mechanical failure of bolts.
We’ve already discussed some of these things. The point is that the single ‘‘essential condi-tion’’ we’ve defined for mechanical failur... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 342 |
a7196c29-4d91-4262-ba5c-8d1e2a8d8c0a | In many cases, furthermore, altering the conditions that lead to one problem can merely
create conditions for another. For example, we know that more preload helps fight vibration
or other forms of self-loosening. Excessive bolt stress, however, can encourage SCC. If we areconcerned about both problems in a given appli... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 343 |
efeb6f1b-098e-43c4-9600-002e2358532d | 13.7.1 C ORROSION
Higher stress levels (higher preload) can make a material more anodic, more active in acorrosive environment. Insufficient preload can allow electrolytes to leak from pressure
vessels and piping systems, exposing the bolts to corrosion attack.
13.7.2 S TRESS CORROSION CRACKING
Excessive preload can ra... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 343 |
0a9ab7bf-12bc-4566-a308-d7e69408dede | 13.7.5 S ELF-LOOSENING OF FASTENER
Insufficient preload can allow transverse slip of the bolt and joint members, an essentialcondition for self-loosening. A major weapon against joint failure, therefore, is the correctclamping force on the joint. This, in turn of course, depends on the correct preload duringassembly an... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 343 |
45b0ad2a-95f5-4fae-8f52-5afdf87e0b10 | 13.8 LOAD INTENSIFIERS
A large number of factors can contribute to the failure of bolted joints. In fact, this whole
book could be called a discussion of such factors. It’s worthwhile listing some of them here,however, to emphasize their effect on joint integrity.
Parts fail when subjected to loads which exceed their s... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 344 |
4e590bc1-649f-4d2f-befd-3b06cacca192 | In Chapter 11, for example, we saw that bolt loads are increased by prying action if the
bolt and external load are not coaxial; and that the problem is magnified if joint membersaren’t stiff enough. Someone has discovered all this and opened our eyes to it, which is lucky,because this particular load intensifier is an... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 344 |
a5f1f031-b568-485e-b751-e5154aec94bd | Nonuniform preload in a group of bolts can cause a few of them to carry more than their
share of the total load placed on the system.
13.9 FAILURE OF JOINT MEMBERS
We’ve said that a joint fails when the bolts fail to provide a suitable clamping force, and we’velooked at several ways in which this may happen. What about... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 344 |
409533c1-0062-4c50-927c-6d20f78446e5 | shear loads in Chapter 3, for example, in Figure 3.18. If the bolt holes are too closely spaced,
TABLE 13.1Factors Which Increase the Stress Levels Produced in Bolts
or Joint by a Given External Load
Factor Reference Chapters
Prying action 11
Eccentric loads 19Bending 3Improper bolt =joint stiffness ratio 10,11,15
Shoc... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 344 |
4979c5dd-42ea-4bb6-9f76-20b71fe29205 | the joint can tear through the so-called net section, as in Figure 13.1B. If there are only a few
bolts, and they’re placed too near the edge of a plate, the bolts can pull their way through the
plate, shearing it, as in Figure 13.1A.
It won’t always be the plates which fail, however. In short joints with widely spaced... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 345 |
5ee0b9e0-5f77-409a-974a-e47e1f5b35ae | largest loads (see Figure 12.8). As the loads on the joint increase, relative slip between joint
members occurs first at the outer ends of the members. They’re stretching. This act will distort
the outer bolt holes and will eventually shear those bolts. Failure of these bolts can occur
before the innermost bolts have s... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 345 |
9ca612b3-d983-4900-8809-0dc2d8f3e12a | (B) Failure through the ‘‘net section’’.
FIGURE 13.2 In long joints the bolts will often fail first, starting with the outermost ones because these
see the greatest loads. (See Figure 12.8.)Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C013 Final Proof page 299 26.7.2007 1:50pm Compositor Name:... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 345 |
46161b94-f374-4426-a2b3-00cac8d8a38e | 13.10 GALLING
13.10.1 D ISCUSSION
We have now looked briefly at various ways in which a bolted joint can fail—in most cases
because the bolts have failed to clamp the joint members together properly. Before going onto a detailed look at some of the more important failure mechanisms, I think we should take abrief look a... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 346 |
3f329ff5-b03f-4bbb-a561-460bf5e15eba | stress, an atomic bond can form between them. If we try to loosen a bolt under these
conditions the thread surfaces can tear and gouge each other. They are said to be galled.
Galling is encouraged by such things as lack of lubrication, lack of oxide film on the metal,high contact pressure, and heat. Stainless steel bol... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 346 |
4d3c82c8-4ad1-425a-ac45-1fc0c6424f19 | for some people. These tips are listed in no particular order.
.Use coarse threads instead of fine; use a Class 2A fit.
.Use a good thread lubricant or antiseize compound. Here are some popular choices:
Moly disulfide works well if stresses are below 50% of yield and temperatures are
below 750 8F (400 8C).
FelPro C670 ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 346 |
bb21d91a-524f-4bda-8843-b32bfbaa133e | Grade 2 (pure) titanium fasteners work better than the higher-strength grades of
titanium.
ARMCO Nitronic 60 bolts work well with Nitronic 50 nuts—but not the other way
around, for some reason.
Carpenter Gall-Tough is a recently introduced austenitic stainless steel, which the
manufacturer claims provides good galling ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 346 |
53e2e4a9-de4d-4cb6-a726-f6f8a3a91959 | Iodine, another mild acid, has worked well for some.
In some piping situations, people have removed the entire flange from the system and
soaked it in a mild acid bath.
Note that, after removing a stud on which you have used these mild acids, you should
clean and relubricate the studs as soon as possible to prevent unn... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 347 |
deafdb8a-a5b2-4fea-b892-9939a790b7ff | If the nut or stud has been threaded into a blind hole and you can reach the bottom of the
hole (by drilling through the side of the flange, or block, or vessel, or whatever), drill such a
hole, then tap it for a pipe fitting. Pump penetrating oil under relatively high pressure—2000
psi has been suggested—into the blin... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 347 |
1d52d15c-408c-4695-9033-47c8b7ef9260 | small holes, and insert some pins to retain the collar (as shown in Figure 13.3), then replace
the bolts [3].
EXERCISES
1. Name at least three reasons why some bolts fail mechanically.
2. What is the most common cause of bolted joint misbehavior or failure?
3. Name at least two problems that can be caused by overtighte... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 347 |
7e5c365b-185e-48dc-91b5-e15ac304af82 | 9. Define galling.
Dowel pin “KEY”
Sleeve threaded
on ID and OD
FIGURE 13.3 I galling forces us to drill out a bolt, the hole in the joint can sometimes be repaired by
drilling and tapping a larger hole, then inserting a collar threaded on the ID to accept a new bolt of the
original diameter. Dowel pins can be used as... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 347 |
f3142cf4-5a06-49f3-9477-34e540ba16e2 | REFERENCES
1. Bickford, J.H., Nuclear bolting issues and programs, Pressure Vessel Components Design and
Analysis—PVP , Vol. 98-2, American Society of Mechanical Engineers, New York, 1985.
2. Kulak, G.L., J.W. Fisher, and J.H.A. Struik, Guide to Design Criteria for Bolted and Riveted Joints ,
2nd ed., Wiley, New York, ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 348 |
23130c84-ab4c-46f8-baf8-2d1631be0fb4 | 14Self-Loosening
14.1 THE PROBLEM
When we tighten a fastener, we pump energy into it: tension, torsion, and bending energy.
The fastener is a stiff spring, and we stretch, twist, and bend it.
After we let go, this energy is held in the fastener by friction constraints in the threads or
between contact faces of the nut ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 349 |
59b0cd3f-8fd4-47bb-acc7-44a79815ae9e | length with the inclined plane of the bolt threads pushing the inclined plane of the nut threadsout of the way.
Subjecting the bolted joint to vibration will do this. Under certain circumstances, all
preload in the fastener will be lost as a result. In fact, the fastener itself can shake loose andbe lost. This can be a... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 349 |
c8640c75-bc19-4d5f-99a9-0bc6d9cc273a | instability.’’ That force can be significantly reduced, or lost altogether, as a result of vibration.
It can also be lost by other forms of self-loosening, incidentally. Vibration may be the
most common, but transverse slip, flexing of joint members, thermal cycles, and other things
can also cause a joint to loosen. Th... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 349 |
6f68dda7-7323-4641-8f3f-8280f7b84772 | A few years ago an ASME committee attempted to establish a working group to resolve the
question. It was decided that a substantial amount of money would be required to finance thenecessary research; but the attempts to attract financial support drew a blank. The projectwas, therefore, abandoned.
We’ll examine one of t... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 349 |
ae295772-7cc7-45ab-95b6-ab58c7236324 | Everyone agrees that a threaded fastener will not loosen unless the friction forces existing
between male and female threads are either reduced or eliminated by some external mechanismacting on the bolt and joint. The disagreements concern the type of mechanism that does that.Before looking at these mechanisms, let’s e... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 349 |
0654ac83-889a-4c42-a077-6894bff93e58 | They are created, of course, by the preload or tension in the bolt, which creates a ‘‘normal
force’’ between male and female threads. The nut will turn with respect to the bolt only if
some ‘‘antifriction force’’ (or torque) exceeds the thread-to-thread friction force.
Note that it is not necessary for the antifriction... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 350 |
9619529f-daed-4ddf-b36b-69735e35d93e | the block) plus the small additional force required to accelerate the block (to get it moving).
If someone else were to apply a second force to the block in any other direction—for
example, force 2 in Figure 14.1—and if this second force were enough to overcome the
frictional restraint between block and table, then we ... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 350 |
deeea2e4-f423-490c-910d-7793f5aa8521 | force to move a relatively heavy block across the surface of a table—if those direction 2 vibration
forces were large enough to break most or all frictional restraint between block and table.
12B
A
FIGURE 14.1 If force 2 is large enough to overcome any frictional force which exists between the
block and the table, then... | d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf | 350 |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.