id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
84354a64-c9d4-414d-8edf-fb711960bcf0
Detroit Tool Industries Unbrako.com MacLean ThomasNet.com Gripco Prevailing Torque Nuts Longlok.com Emhart.com Omni-Lok Fasteners LockBolt Nylock.com Huck Fasteners Self-loosening of fasteners Vibration-resistant fastenersBickford/Introduction to the Design and Behavior of Bolted Joints 8176_C014 Final Proof page 304 2...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
350
69dae628-2d27-45f2-b30b-cd98b65bc2a6
The fastener, of course, is not a block on a table. It can better be modeled by the inclined plane and block shown in Figure 14.2. There is now a small force which wants to move the block down the plane—a force equal to Wsinu, where Wis the weight of the block and uis the angle of the plane on which the block is restin...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
351
01cda2f2-d990-4f09-99b1-35b88d95fc0b
the bolt, which creates the force which pushes the inclined plane of the nut out of the way when the vibration forces are broken. This is suggested in Figure 14.3. Note that the bolt in Figure 14.3 must be exerting a force on the nut—or the block in Figure 14.2 must be exerting a (gravitational) force on the inclined p...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
351
6595e2ae-3154-44b8-9cbf-ab957c910539
have been proposed [25,33]. We’ll look at one of these in a minute.qq q W cos qWW sin q FIGURE 14.2 Shaking the inclined plane in the direction shown by the double arrows would destroy frictional constraints between block and plane and allow force Wsinuto move the block to the foot of the plane. ( Wis the weight of the...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
351
d09f2852-1ab1-496b-a506-778eb86d8f58
One thing that has been agreed upon is that vibration is a far greater problem in a joint loaded in shear than in a joint loaded only in tension. Severe vibration parallel to the axis of the bolt, for example, might succeed in reducing preload by 30% or 40% over a long period of time. But it will usually not result in ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
352
13797947-4c0f-456a-bfda-8ae937f8ca34
with a pencil—in any direction—or bang it up and down, the block will slip to the foot of the plane just as readily as it would if I shake the plane back and forth in the direction shown by the arrows. In this case, therefore, the direction of vibration would be unimportant. In the bolt, of course, it’s easy to see how...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
352
a8f806a4-b983-494e-a0e7-4eb9ccdd33b0
Axial vibration would actually increase the contact forces and strains between parts during part of each cycle. In fact, at least one reference [3] says that axial vibration can sometimes tighten a bolt as well as loosen it. Severe axial vibration, however, can cause periodic dilation of the nut, creating the relative ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
352
19148364-07ad-4986-a589-efe89a24a772
All agree that a fastener subjected to shock or vibration or thermal cycles will not lose all preload immediately, but will first undergo a relatively slow loss of preload. No one knows for sure why this progressive loss occurs, but it has been well documented [1,12]. Most seem to think that cyclic forces applied to th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
352
bac69eac-b90b-4865-9cd9-11d94b327941
known is probably that of Gerhard Junker [1]. His work has been published in many forms,Center of rotation FIGURE 14.4 Vibration along the circular path will sometimes tighten, sometimes loosen, and some- times do ‘‘neither’’ to a fastener.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C014 Fina...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
352
7bc362ef-e925-4b32-8c6a-13aa1c4ee853
and has apparently been confirmed by experiments conducted on a ‘‘Junker machine,’’ which we’ll discuss later. Further confirmation comes from results obtained with special vibration- resistant fasteners whose designs have been based on his theories. His theory is, therefore, a reasonable starting point. Let’s look at ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
353
3bdc3daa-2b0d-4e15-8f30-da7d165acd5f
rapid beyond this point. (Modified from Junker, G.H., New Criteria for Self-Loosening of Fasteners under Vibration , October 1973, Reprinted from Trans. SAE , 78, 1969.) (A) (B) (D) (C) FIGURE 14.6 Illustration of the process by which fasteners loosen, according to Gerhardt Junker. See text for discussion.Bickford/Intr...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
353
85cdb150-869b-4e9f-bda7-327453a68181
The form of the equation I prefer, because I find it most descriptive, is a simplified version proposed by Nabil Motosh [21]: Tin¼FPP 2pþmtrt cosbþmnrn/C18/C19 (14:1) where Tin¼torque applied to the nut (in.-lb, N mm) FP¼preload in bolt (lb, mm) P¼thread pitch (in., mm) mt,mn¼coefficient of friction in thread and nut s...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
354
b2a07256-d7ac-44ab-b43a-ff836feec1f6
The long-form equation is believed to explain, correctly, the basic relationship between input and reaction torques in a threaded fastener. In practice, however, it is virtually useless as a means of predicting the exact relationship between applied torque and achieved preload in agiven fastener, since we never know wh...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
354
e56e02c2-5065-486d-a184-62626b967c70
concerned with the torque created by the elastic stretch of the bolt and the frictional reaction torques. Note that the elastic torque still wants to rotate the nut in a counterclockwise direction, as it did while the bolt was being tightened. The friction torque, however, hasnow reversed sign because it’s opposing the...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
354
ee204d8f-707c-4379-8370-c72245f8fa0c
As an example, in an ASTM A325 fastener, of 1 in. diameter with eight threads per inch tightened to proof load ( F P¼51,500 1bs), the coefficients of friction would have to drop to about 0.015 before there would be a net, internal off-torque to loosen the bolt. This isone-fifth to one-tenth of what we would expect the ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
354
7b003608-ce1b-42c0-b4ea-50d486314ea4
Some other factor must enter the picture if loosening is to occur. Junker attempts to explain this other factor. He suggests that (assuming that no locking or prevailing torquedevice is present) 1. The elastic stretch in a bolt will create a torque that attempts to loosen the nut, as suggested by the long-form equation...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
355
0a7c8f10-854e-4891-a133-88d15cf3b5e7
the system are great enough to overpower the friction or other forces which resist slipin the threads and between bolt and joint. 5. How much energy will be lost during each cycle depends on the ‘‘thread-slip distance’’ involved; the greater the thread clearance, the more energy will be lost each cyclebefore slip ends ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
355
51bb0baf-2cb3-431d-857c-9f14c6f4eb27
1. As a result of the previous cycle, the nut and bolt are in the relative positions suggested by Figure 14.6A—where thread clearance has been magnified for clarity. 2. Now the top joint member starts to move toward the right; the lower member moves left. 3. At first, the nut and bolt remain in the relative position sh...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
355
81e3fceb-d226-4047-bd8a-7b9f648d9727
held by friction forces (Figure 14.6C). 5. If conditions are severe enough, however, the head of the bolt also slips against the adjacent joint surface—after the bolt threads have started to slip over the nut threads.Under these conditions both ends of the bolt are momentarily free and it will rotateslightly, losing a ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
355
8e359541-49d5-441f-a7d8-d97c58cd8385
The loosening sequence described above has been supported by experiments made on a ‘‘Junker machine,’’ shown in Figure 14.8 and discussed in Section 14.5. Careful measurementsshow the brief instant during which slip occurs, as well as those portions of the cycle duringwhich the bolt is clamping the upper and lower join...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
356
afab859c-2377-47f5-b65e-124a45723489
14.4.5 O THERREASONS FOR SLIP Although Junker doesn’t mention it, slip can presumably be caused by factors other thanbending of the bolt. The bolts don’t necessarily bend during a MIL-STD-1312 test, forexample, but nuts loosen. Inertial forces presumably cause the slip there. There may beother situations where a combin...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
356
4de5cd44-b869-4e73-90ba-4e6fdb2a2361
by Nassar and Housari at the July 2005 Pressure Vessel and Piping (PVP) Conference [38] and by Wang et al. a year later at the PVP Conference in July, 2006 [33]. The authors describe atwo stage self-loosening sequence. The first stage involves plastic deformation of the threadsnear their roots. Some bolt tension is los...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
356
1bc19c15-b27e-4312-8ca6-4c90591e6265
14.5 TESTING FOR VIBRATION RESISTANCE In a moment we will look at many ways to improve the vibration resistance of a bolted joint. Since we can’t predict vibration loosening mathematically, the usefulness of such techniquesmust be determined experimentally, in a test machine. Experts warn that it is not sufficient to c...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
356
f0c9c4e7-0217-4c9c-8af6-f58cfafec05a
however. If possible you should always repeat the test on the actual joint: hopefully the one you are having trouble with—to be sure that you have really made a difference. Our knowledge of vibration loosening is entirely empirical, and there are many factors whichcan make a difference. Some experiments, in fact, have ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
356
a37c684b-8814-4ef9-a86f-15692e507e27
14.5.1 NAS T EST One popular way to test for vibration resistance is shown in Figure 14.7. The nut and bolt aretightened onto a small cylinder. This cylinder is placed in the slot of a test block. The cylinderBickford/Introduction to the Design and Behavior of Bolted Joints 8176_C014 Final Proof page 310 26.7.2007 1:20...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
356
c7453c0d-f602-4d56-9fe9-a4788c5bd56e
is longer than the block, and washers are used at both ends so that the cylinder is free to bang around in the slot without being able to fall out of it. The block is vibrated in a vertical direction, causing the fastener and its cylinder to bang back and forth between the top and bottom of the slot until the nut and b...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
357
9aebae8e-ecfa-47b8-8a60-4e261435d8f7
and reinstalled 3–5 times depending upon the fastener being tightened, before being subjected to the test. Counterclockwise rotation of the nut of more than 360 8constitutes failure. This is a very severe test procedure. Many types of vibration-resistant fasteners which survive a controlled Junker test loosen rapidly d...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
357
da3c38a1-01c3-4626-b967-08ec401dd2d3
The test machine shown in Figure 14.8 is called the Junker machine. An eccentric cam generates a controllable amount of transverse displacement on the joint under test. Force cellsShake table FIGURE 14.7 The NAS vibration test. The fastener under test is mounted in a cylinder which is free to bang up and down within th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
357
d6ca674a-a5d3-4897-a16a-835029ad9c0f
measure the actual transverse forces exerted on the joint. One can now determine the relation- ship between residual preload in the fastener under test and external vibratory forces created bythe test machine as a function of time. SPS used to make and sell Junker machines, but they nolonger do that. The SPS Laboratory...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
358
6ee639cd-6395-4a9e-a4e8-0fcda298eca8
purpose. Hess describes half a dozen or so alternates, for example [28]. Theoretically, when you test a fastener for vibration resistance, you would like to subject it to the vibration frequencies and magnitudes you expect the joint to encounter in yourapplication. Predicting the vibration environment a given product w...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
358
f5543432-880d-4b23-9239-872ee52af954
14.6 TO RESIST VIBRATION In Chapter 13 we learned that self-loosening will occur only if two essential conditions arepresent: cyclic, transverse loads, and relative slip between thread and joint surfaces. Junkerand several others suggest various ways in which these conditions might cause self-loosening.According to mos...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
358
b19aa65f-88a9-43b5-ba60-dd3479e3b376
1. Keep the friction forces in thread and joint surfaces from falling below the forces that are trying to loosen the nut. 2. Mechanically prevent slip between nut and bolt or nut and joint surfaces. 3. Provide a prevailing torque or locking action of some sort, which counters the back-off torque created by the inclined...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
358
9753573f-6cdd-4803-988d-f45ad2b604eb
It also helps to reduce the helix angle of threads to reduce the back-off torque component (Wsinuin Figure 14.2). Let’s look at some of the ways we can accomplish the three goals. 14.6.1 M AINTAINING PRELOAD AND FRICTION 14.6.1.1 Conventional Wisdom The least expensive and simplest way to fight self-loosening is often ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
359
e21ff251-efd9-4b65-865d-3805a2e45726
It is generally agreed that we want to tighten the fasteners to the threshold of yield if we need maximum vibration resistance [7,8]—always recognizing, however, that we may not be able to tighten them this much if external loads or safety factors make this much preload unwise. As far as vibration resistance alone is c...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
359
7457cc5d-a537-4d06-a835-38d2c9f687f1
Introducing some form of vibration damping can also help maintain friction, as men- tioned earlier, because it reduces the rate at which preload will relax under vibration. Nylon inserts in the bolt or nut threads are said to be an effective way to accomplish this [3]. They presumably also prevent side slip between mal...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
359
052cf21c-ffe1-442d-8c43-9f3378d4f75c
Preload (Percenta ge of ultimate stren gth)Cycles to failure 0 50 100 FIGURE 14.9 Vibration resistance of a Grade 5 fastener as a function of preload (expressed as a percentage of yield strength).Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C014 Final Proof page 313 26.7.2007 1:20pm Compositor...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
359
e2f87cdf-8e68-4c5e-9b36-822a517a3279
Anything else which reduces the amount and rate of relaxation will also be helpful. If possible, for example, you should avoid gaskets in a joint subjected to severe vibration. 14.6.2 P REVENTING RELATIVE SLIP BETWEEN SURFACES Providing and maintaining adequate bolt tension is probably the easiest and least expensive w...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
360
8efbf05f-8c24-432c-a62a-c03510fcd802
that bolt axes are parallel to the expected direction of vibration. Remember that axial vibration is far less of a problem than transverse vibration. In many cases a designer can shape the joint so that relative slip between joint members is prevented or at least minimized. Remember that there must be actual slip befor...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
360
39714aca-b30a-4e4c-b095-899084aba47a
Experiments have indicated that the nuts of long, thin fasteners won’t slip over joint surfaces under transverse vibration; instead, the fasteners bend. One knowledgeable source says that a length to diameter ratio of 6:1 provides optimum resistance to self-loosening [30]. Another authority says that if the length-to-d...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
360
bca4400c-8361-4cdb-aa99-66026dea1967
We can, however, reduce the off-torque by decreasing the helix angle. The only practical way to do this in most situations is to use a fine-pitch thread instead of a coarse-pitch thread. This can make a useful difference, as shown in Figure 14.11. Hess reports on an experiment in which fine pitch threads endured twice ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
360
288e39a7-0456-4ec6-ad7f-4ec6355d05cd
14.6.3 C OUNTERING BACK-OFFTORQUE When all else fails—and it often does—the only thing we can do to fight vibration loosening is to provide another source of torque to counter the back-off torque produced by the inclined planes of the threads. Now, even if vibration totally destroys all friction forces, some other mech...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
361
ff10016d-5015-43f2-811e-6c7d6e4dfdb7
threads to create interference, and (3) nuts with a collar or ring of nonmetallic material, again0020406080100 10 100 1000 Number of cyclesBolt tension (percentage of original preload) FIGURE 14.11 Reducing the helix angle of the threads by using a fine-pitch thread instead of a coarse- pitch thread can make a useful d...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
361
7ffa08db-90fd-4dcc-88c1-5646ab3e4ba0
to create interference with the mating bolt and, in this case, as discussed earlier, to dampen the resonant frequency vibrations of the fastener. Visit ESNA and GRIPCO on the Web fordetails of currently available products. Tests conducted by several groups suggest that nutswith nylon inserts provide unusually good resi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
362
9ec7cbdd-aa61-47fd-b3d1-7d82003e8919
Type of NutRelative Number of Cycles Required to Shake Nut from Bolt Nut with locking ring of nylon 100 Beam-type self-locking nut—aircraft 53 Castellated nut and spring pin 38 Distorted thread nut—aircraft 19Castellated nut and cotter key 18Beam-type self-locking nut—commercial 4–17 Distorted thread nut—commercial 1–1...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
362
e993687f-39e7-463a-933f-928eb70fc27f
Evaluation of Screw Thread Loosening in Bolted Joint with Some Parts for Preventing the Loosening Under Transverse Loading. Proceedingsof PVP2006-ICPVT-11, ASME Pressure Vessel and Piping Division Conference, Vancouver, BC, Canada, July 23–27, 2006. With Permission. Note: The tests were made in a Junker’s machine. Resu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
362
341f0771-68e2-4ef9-9b13-0647ba89995b
are those which would be acting to prevent ‘‘self-removal,’’ and so are also of interest. Prevailing torque nuts are covered in IFI Standard 100 =107. English and metric series bolts are covered in IFI 124 and 524, respectively [24]. Free-spinning lock nuts or bolts can be run down with normal (very little) torque. As ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
363
973edcdc-8d3f-4595-b03f-06d4a756d7f5
nut is tightened, the tips of the male thread are forced into interference fit with the ramps. This eliminates all clearance between male and female threads. The inventor of this thread form, Harold (Ace) Holmes of Detroit, is a firm believer in the Junker theory of vibration loosening. He designed the Spiralock thread...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
363
2f6cc83e-38f9-489e-8dea-36db8d4507ee
the root ramps of the female threads. Another feature: the Spiralock thread form creates a more uniform distribution of load and stress than does a standard thread form. For example, Nayak of MIT says that only 18% of the tensile load in the bolt is transferred to the first engaged thread versus 34% in a standard threa...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
363
91de95bd-7cfd-4052-88d7-1a6745868958
into joint surface and resist reverse rotation; serrated face nuts are also available); (C) spring head nut, which distorts inwardly to pinch bolt; and (D) spring arms on top of nut provide interference fit with bolt threads (called beam-type nut).Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
363
762e6b4e-7b68-4418-903a-13c8693a18f5
14.6.3.2 Nord-Lock Nuts and Washers The nuts and washers shown in Figure 14.14 are made by the Swedish company Nord-Lock AB [36]. They also used to be called Disk-Lock products, but that name is not currentlyfound on the Web so I assume those products are no longer available. The two piece Nord-Lock washer is, I think,...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
364
e5d55982-d2b7-4d46-a5a5-e123ad8e5e0a
Nord-Lock washer is, I think, more popular than the Nord-Lock nut but both work on the same principle. For example, mating surfaces on the two-piece washer have interposing,multitoothed cams; a series of short ramps whose angle exceeds the pitch angle of boltthreads. Sharp ridges on the other sides of the washer dig in...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
364
2500536e-7938-4929-b05c-763909bdeff9
to loosen. These washers resist self-loosening during a Junker test more effectively than manyother products [34]. They are available in ID’s ranging from about 1=8in. (3.4 mm) to about 5 in. (133.4 mm) and can be obtained from many different domestic and foreign suppliers asyou’ll see if you visit Nord-Lock on the Web...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
364
580d0674-6678-428b-8118-3dd1a3dc6af7
lead angle of the bolt threads, so any counterclockwise rotation of one half of the two piece washer, or of the two piece nut, can actually increase the tension in the bolt.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C014 Final Proof page 318 26.7.2007 1:20pm Compositor Name: VAmoudavally 318...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
364
2478bfed-95df-4659-93cc-32660cfa6525
.Operating temperature limits .Mating thread accommodation .Effect on mating parts (may damage or Brinell them) .Reusability .Type of installation tools required .Effect on the mechanical properties of mating parts (for example, does it reduce the fatigue life of another part by providing a ‘‘softness’’ in the joint or...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
365
23803d50-4722-483b-b623-e772eae72c76
then the outer nut is tightened, as in the conventional procedure. A wrench is then used to partially loosen the inner nut, presumably raising it into harder contact with the outer nut.Both nuts are then tightened together to complete the process [34]. 14.6.5 M ECHANICALLY LOCKED FASTENERS Sometimes it’s impossible to ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
365
2ec69940-6687-4939-91ab-394923257967
both new and old options in this category. 14.6.5.1 Lock Wires and Pins The earliest attempts to prevent self-loosening of a threaded fastener probably involved lock wires, keys, and cotter pins; and these still find a lot of use. A couple of examples are shown inFigure 14.15. These can effectively prevent total loss o...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
365
b49a8aac-1f8b-4475-96f2-f350fb286945
Nuts can be welded to bolts, at least if they’re large enough. The normal procedure is to tack weld the nut to the end of the bolt. Another procedure is to tack weld both the nut and the head of the bolt to joint surfaces. Either procedure makes removal of the nut (for maintenancepurposes, for example) very difficult a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
365
b4ec725e-6402-4de8-9c29-5eaf88923c19
14.6.5.3 Stage 8 Fastening System The Stage 8 fastening system, shown in Figure 14.17, fights loosening in still another way. The bolt and nut are conventional except for snap-ring grooves, as shown. Loosening is resisted byBickford/Introduction to the Design and Behavior of Bolted Joints 8176_C014 Final Proof page 319...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
365
fde9c613-9aa4-42fb-aa21-e1e247a7d9a4
a retaining arm which is slipped over the nut or bolt head. The far end of the arm butts up against an adjacent nut or other reaction surface to prevent counterclockwise rotation. The snap-ring prevents loss of the retaining arm. A wide variety of retaining arms, collars, rings, etc. are available, depending on the bol...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
366
68863320-8f46-4914-85bf-7fc74b7062b1
C6L LockBolt is designed especially to fight vibration. (See it on their Web site.) 14.6.5.5 Honeybee Robotics Honeybee Robotics has designed a vibration-resistant fastener under funding from NASA. Standard bolts are used with nuts whose threads have been modified. The nut threads haveFIGURE 14.15 Lock wires and cotter...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
366
3cfba874-8957-450e-b18b-08ba30a77711
flat ends and an included angle which differs from the standard. When tightened, the crest of the nut threads digs into the roots of the bolt threads, giving the fastener significant resistance to vibration. 14.6.5.6 A-Lock Bolt and Nut Shap, Inc. of Hacketstown, NJ, makes vibration-resistant bolts and nuts with unusua...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
367
e2f78f40-6bbe-4553-b17b-9f6185ceee5a
rotation of the nut or bolt. A variety of reaction arm configurations are available. FIGURE 14.18 The Shap, Inc. A-lock thread form. When tightened the threads wedge together to resist self-loosening.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C014 Final Proof page 321 26.7.2007 1:20pm Compos...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
367
503c6539-afa7-48b1-8935-c702c2483ea8
14.6.5.7 Omni-Lok Fasteners These fasteners are locked by one or more pins that are inserted parallel to the axis of the threads. The OD of the pins extends above the root diameter of the external threads, andbelow the minor diameter of the internal threads, eliminating self-loosening. The pins can be made of a wide va...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
368
766ec584-c81e-4310-8fb0-0190d109ac2e
small as well as large fasteners. Also contributing to their popularity, the chemicals cost little and can be used on standard fasteners. In many cases the chemicals are applied by the userbefore assembly; in other cases they’re applied by the manufacturer. Several chemicals are used,including acrylics, but I believe t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
368
a6768a1d-f421-4d79-9ec5-1a64d859a5a5
Petrochemical engineers often find rain helpful. 14.6.6.2 Anaerobic Adhesives One very good way to resist off-torques is to ‘‘cement’’ the nut and bolt together. The most common way to do this is with an anaerobic adhesive, a material which is activated (hardens) when subjected to high pressure in the presence of metal...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
368
75e9158a-cc3a-46a8-b74e-6dbcc98771cd
We learned earlier that it is important to know how much torque will be required to install a prevailing torque fastener, because that torque must be added to the torque required toachieve a desired preload. The same is true of fasteners coated with anaerobic adhesives orother chemicals. We’re also interested, of cours...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
368
e6e0074e-1bde-4bdb-a7f7-8c4e08ab1713
IFI-125 covers English series fasteners; IFI-525 covers metric series fasteners [24]. Locktite, the first company to provide anaerobic adhesives, says that the adhesive also fills the gap between male and female threads, preventing relative side slip and preventing moisture from corroding thread surfaces. This keeps th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
368
fc79447b-914f-4ea2-8fe3-18f909f3cb2d
fasteners have not been previously exposed to certain oils or cleaning solutions which prevent the adhesive from curing. The total length of the thread must be wetted. Properly applied anaerobics create a nut factor of 0.14–0.17 on steel, and so can serve as an assembly lubricant. They can be used at service temperatur...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
369
6951bcaf-b9ff-4fe3-b617-e40f4851ab4b
Obviously, almost all tension will have been lost in the bolt before the wave washer takes over. Its effectiveness must be questioned, to put it politely. One source says that wave, toothed, and fan washers are inadequate to prevent self-loosening in fastener of SAE Grade 5 (metric 8.8) or higher strength material [30]...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
369
0263c3cd-6e85-4d89-b98c-487b1e7ced6f
suggested in Figure 6.17. Smaller Bellevilles, used singly, are also called ‘‘plate spring washers,’’ and are quite effective in fighting self-loosening. They are available in sizes ranging down to about1=4in. (6 mm) ID. At least one source can also provide them up to 39 in. (1003 mm) in size [36]. 14.6.7.2 Toothed Was...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
369
4af47bad-9e38-47d6-b4a1-262205a639ab
some spring tension in the bolt after the nut has loosened; but I doubt if it’s of much help. The toothed washer (B) digs into both nut and joint surfaces and fights relative motion between them. The Belleville washer (C) is often used in stacks, on large fasteners in pressure vessel and similar applications. A stack p...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
369
0b869e1c-4822-4da6-80aa-bc4f6cfe6fcd
14.6.7.3 Helical Spring Washer At first glance the helical spring washer shown in Figure 14.20 would appear to be of as little value as the wave washer; unless the cut ends manage to bite into joint and nut and resist relative motion the way the toothed washer does. Research at the Lawrence Technological University in ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
370
5041e2a1-7faf-44d4-9dfe-5956e61abdb5
approach 65% of the spring rate of the fastener. That spring rate will dominate the behavior of the fastener under load, and will reduce the amount of preload lost under a given applied load. Retaining preload, of course, is an effective way to resist self-loosening. 14.6.7.4 Nord-Lock Washer To complete the list of wa...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
370
a870e4c7-a154-40ab-98de-4f1df524e14e
number of different possibilities from the point of view of one manufacturer (who provides all of the methods tabulated) and may or may not be pertinent for your own applications [17]. Table 14.3 rates others from the point of view of a different manufacturer [19]. Table 14.4 is the most recent comparison I’m aware of ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
370
8469c8ed-c2ab-4df7-b4e2-e374942dfba5
3. With reference to Equation 14.1, explain the terms FPP=2p,FPmtrt=cosb,a n d FPmnrn.Load Twist FIGURE 14.20 A helical spring lock washer would appear to be a fairly inefficient way to resist self- loosening; but recent research—described in the text—shows that this washer twists and rolls when it’s fully loaded. Sinc...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
370
75027299-5358-40b5-bcfa-8677287b4786
4. Does the well-accepted Junker theory explain all self-loosening phenomena? 5. Describe the MIL-STD-1312 (NAS) test.6. Name three generic ways to prevent or at least minimize self-loosening.7. Define prevailing torque. 8. A proper length-to-diameter ratio for the bolt can reduce or eliminate self-loosening. What L=Dr...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
371
c47d1713-8dc1-4634-b53a-b4c697ec73b5
September 1978. 3.Maintaining the Tightness of Threaded Fasteners , ESNA Division, Amerace Corporation, Union, NJ, 1976. 4. Shigley, J.E., Mechanical Engineering Design , 3rd ed., McGraw-Hill, New York, 1977, p. 244. 5. Landt, R.C., Vibration loosening—causes and cures, Presented at Using Threaded Fasteners Seminar, Un...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
371
8ef89eca-386a-46b9-b1cd-4c4b7895ce26
9. McKewan, J., The effects of plating on torque-tension relationships and vibration resistance, Paper no. 800452, Congress and Exposition of the SAE, Cobo Hall, Detroit, MI, February 19, 1980. 10. Hardiman, R., Vibration loosening—causes and cures. Presented at Using Threaded Fasteners Seminar, University of Wisconsin...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
371
0c350911-a001-4f21-b63e-801a885841c5
Technologies, Jenkintown. PC, published in Machine Design , April 1980. 15.Loctite1Technology , Loctite Corp., Newington, CT, 1979. 16. Ingenious locking concepts abound, Product Engineering , p. 39, March 1979. 17. Finkelston, R.F. and P.W. Wallace, Advances in high performance fastening, Paper no. 800451, Presented a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
371
2e56421b-b43c-4932-9f5e-a1f440d9ef06
May 1980. 21. Motosh, N., Development of design charts for bolts preloaded up to the plastic range. Journal of Engineering for Industry , August 1976. 22. Chambers, C., Spring rate of helical spring lock washers, Lawrence Technological University, Southfield, MI, 1991.Bickford/Introduction to the Design and Behavior of...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
371
debbda9c-823b-4e18-b96d-c6d017f7f134
23. From information furnished by the MacLean-Fogg Co., Fasteners and Assemblies Division, Mundelein, IL, 1994. 24. Standards published by the Industrial Fasteners Institute of Cleveland, Ohio, as listed below: IFI 100 =107, Prevailing-torque type steel hex and hex flange nuts, regular and light hex series, revised ver...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
372
5b673817-11c7-4eef-92b6-24f5ca94be66
25. Petras, J., Designing with locking fasteners, Fastener Technology International , pp. 48–49, December 1993. 26. Nayak, P.N., Spiralock: vibration resistance and stress distribution, prepared at MIT for the Chrysler Corporation, published by Spiralock, Detroit Tool Industries, Madison Heights, MI. 27. Harrel, A., II...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
372
4431d065-bd01-496f-aec8-630cd602731c
30.Loctite: Worldwide Design Handbook , 2nd ed., Loctite North America, Hartford, CT, 1998. 31. Information obtained on their Web site about the A-Lok fastener made by Shap, Inc., Hackerstown, NJ. 32. Information obtained on the Long-Lok Web site about their Omni-Lok vibration resistant fastener. 33. Wang, Z. and Y. Ji...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
372
ed0fe340-501d-40bf-9c77-7eedc6cf0efd
35. National Aerospace Standards: NAS 3350, Nuts, Self Locking, 450 8F and 800 8F High Quality and NAS3354, Fixture-Vibration Test—Self-Locking Nuts. 36. From the 2006 Web site of the Swedish company Nord-Lock AB.37. From the Web site of Key Belleville, Inc.38. Nassar, S.A. and B.A. Housari Self-Loosening of Threaded F...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
372
485448ce-fdb4-4a55-a60b-e73c09e36fc3
15Fatigue Failure A metallic part subjected to cyclic tensile loads can suddenly and unexpectedly fail—even if those loads are well below the yield strength of the material. The part has failed in fatigue.Note that the failure occurs under tensile loads. I’ve heard that fatigue failure under cycliccompressive loads is ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
373
ad158694-104f-4017-8a37-84d5314d7cbb
15.1 FATIGUE PROCESS 15.1.1 S EQUENCE OF A FATIGUE FAILURE We learned in Chapter 13 that fatigue will be a potential problem only if four ‘‘essential conditions’’ are present: cyclic tensile loads, stress levels above a threshold value (called theendurance limit), a susceptible material, and an initial flaw in that mat...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
373
4d237bcd-73a4-4ca9-b9e2-38216347c45c
15.1.1.1 Crack Initiation Many things can produce that first fatal flaw which starts the fatigue process. A tool mark can do it. So can a scratch produced when the part is mishandled. Improper heat treatmentcan leave cracks. Corrosion can initiate them. Inclusions in the material can do it. It isprobably safe to say, i...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
373
8f56929e-dd34-4d7f-bd65-96a76bfc6184
15.1.1.2 Crack Growth A tiny crack creates stress concentrations. When the part is subjected to cyclic tension loads, these stress concentrations yield and tear the material at the root of the crack. Since most of the bolt still remains undamaged to support the load, initial crack growth is fairly slow. 15.1.1.3 Crack ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
374
e6024fa1-8b05-4d5c-8f92-1c89f2c6c7a3
often no visible damage or change in the behavior of the bolt. Everything appears to be fine until suddenly, with a loud bang, the bolt breaks. The number of cycles required to break the bolt this way is called its fatigue life. Apparently identical bolts in apparently identical applications can have, of course, substa...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
374
58afd813-3c40-48d2-a53a-66e58bd3b87a
Fatigue failures are called high-cycle or low-cycle failures, depending on the number of load cycles required to break the part. High-cycle fatigue requires hundreds of thousands or even millions of cycles before rupture occurs. Low-cycle failure occurs in anything from one to a few ten thousand cycles. You can demonst...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
374
7591ef57-0144-41e2-ada5-15b6f4d271fc
the crack is so large that the next cycle of load breaks the bolt. The stages of failure are (1) initiation, (2) growth, (3) propagation, and (4) rupture. (Modified from Keith, G., Standco Industries, Inc., Houston, Texas, Personal communication, 1979.)Bickford/Introduction to the Design and Behavior of Bolted Joints 8...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
374
191d4a6f-5927-41d9-9a8a-8d5b6dd17bf5
In many applications the bolt can see some of each—lots of relatively mild loads interrupted once in a while by a sudden shock or larger load (perhaps when the tractor hits a rock). In many cases it’s difficult to know whether to characterize the failure as a low-cycle or a high-cycle failure. In most well-designed bol...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
375
9e8f2b45-c6f8-48f7-8a34-e7d8ff1e8659
rough surface. If the entire fastener fails suddenly during tightening or the like, the entire break surface will be rough; so these smooth ‘‘beach marks’’ seen on a fatigue surface can be used to distinguish fatigue breaks from breaks which occur under static load, see Figure 15.2. You may find more than one crack in ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
375
1177341d-ab9a-4b78-b1ff-ef1dfb6e4fc7
the thread run-out point, the first thread or two of engagement in the nut, and any place where there is a change in diameter of the body or shank. 15.2 WHAT DETERMINES FATIGUE LIFE? In general, the higher the cyclic loads seen by the bolt, the sooner it will fail. Whether or not, or how rapidly, a fastener will fail d...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
375
acb64b50-18ae-4b09-bdc9-5dcef1169e72
interest—in our case, on a bolt. Test results are usually presented in the form of S–N diagrams, where Sstands for stress level and Nfor number of cycles of applied load. An examination of these diagrams gives considerable insight into the fatigue process. 15.2.1 S–NDIAGRAMS Figure 15.3 shows one possible form of the S...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
376
6b99ef49-4b77-4d9c-8436-aa9b13e48bb8
necessary to test many coupons before plotting the results shown in Figure 15.3. The statistical deviations in life can also be determined by such tests. A more complete picture of the tests, therefore, would be shown by a diagram such as that given in Figure 15.4. Note that many of the test specimens will fail at some...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
376
dbf5c798-160d-4459-b790-577102386258
applied alternating stress levels are very high. As alternating stresses are reduced, cycle life increases. Below some stress level, in fact, the curve becomes essentially parallel to the hori- zontal axis, and fatigue life becomes very large. This stress level is called the ‘‘endurance limit’’ of the material, or part...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
376
ae7a0dbe-866c-4976-9b5e-ed269159fdda
104105106 Cycles to failure ( N)Stress amplitude (S) (in psi) 107108 FIGURE 15.3 The mean life of a group of test coupons subjected to fully alternating stress cycles. When stresses are ‘‘full alternating,’’ maximum tension stress equals maximum compression stress and the mean stress on the part is zero. (Modified from...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
376
d4dd2001-8f0c-4219-8e48-e73f75ab22b0
endurance limit. Aluminum alloys, for example, exhibit finite life even at very low cyclic stress levels [18]. We could now test another large number of test specimens, this time changing the mean tension while leaving the excursion (difference between maximum and minimum tension) the same as it was in the previous tes...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
377
2caf1ee6-b484-4b46-ba83-72a26bc0abd3
result of a particular stress pattern. Rather than show just the mean life results as in Figure 15.3, therefore, it is sometimes useful to plot the statistical deviations as well. (Modified from Wayne, D.M., Fatigue design considerations in bolted joints, presented at Using Threaded Fasteners Seminar, University of Wis...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
377