id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
73c3c3a0-575c-40d6-b3ab-798612184cd3
current and complex geometry of the cavity and cathode. Currently, cavity electropolishing machines do not employ a reference electrode and instead only set a fixed voltage between the anode and cathode. This means that cathode losses and ohmic losses in the electrolyte can significantly alter the polishing potential a...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
12
6de968eb-7f34-451b-af2e-504883e47231
information can be used to tweak the EP parameters such as voltage and temperature to ensure that the cavity is in an optimal polishing regime. This technique may be useful when electropolishing complex cavity geometries such as quarter-wave and half-wave geometries. 13
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
12
e16f8d26-8787-4094-974d-7d21418e9d05
Figure 5: The Distribution of relaxation times calculated from the EIS impedance data for each of the measured potentials. The current-voltage curve is shown in the graph on the left. The left DRT plot shows eigenvalues that are less than zero, which correspond to stable eigenvalues. The right DRT plot shows eigenvalue...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
13
17e02221-d556-4e37-8b88-0cd12974b657
NbS0NbOS1 k10k01 Nb2O5 S2k21k12 NbsolS3k13 k23 Figure 6: Proposed mechanism for niobium electropolishing in HF-containing electrolyte by a two step oxidation reaction. Figure 7: The surface height maps of Nb samples electropolished at different voltages and temperatures. 15
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
14
1708afc5-b136-44c6-9c6e-1f1317726826
5 Conclusion In this study we find evidence that the etching phenomenon seen in electropolished SRF cavities is caused by insufficient polishing voltage and investigate the mechanism behind it. Niobium polished below a critical voltage will experience etching whereas niobium polished above this voltage will experience ...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
15
4a9995fa-c0de-41ef-a12e-97d11da16f72
most likely caused by the oxide film which forms when HF is depleted near the niobium surface and the oxidation rate exceeds the rate of dissolution by HF. 6 Acknowledgements The authors would like to thank Dr. Noam Eliaz and Dr. Eyal Sabatani for their insightful discussions and recommendations during the authoring of...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
15
51f70310-5aa9-4783-b0ee-57f280f0aec4
merical techniques used in this paper including the derivation of the first order and higher or- der impedance response of linear systems and the derivation of the generalized DRT method. The details of calculating the DRT of Nb EP to produce figure 5, such as chosing the basis functions and normalization parameters, i...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
15
944ffccf-9bad-48f0-a1a3-2419163caac3
For a system that satisfies the above mentioned stability condition, the non-linear system of equations can be linearized near its stable point using a first order Taylor expansion, written in matrix notation as shown below. ⃗P=⃗P0+δ⃗P (13) E=E0+δE (14) I=I0+δI (15) dδ⃗P dt=Aδ⃗P+BδE (16) δI=Cδ⃗P+DδE (17) (A)i,j≡Ai,j=∂...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
16
7b57d78d-5d20-444f-8ba0-4a3784121d6e
potential in the Laplace domain. eX≡L(X) (22) sδeP=AδeP+BδeE (23) δeP= (sI−A)−1BδeE (24) δeI=CδeP+DδeE (25) δeI=C(sI−A)−1BδeE+DδeE (26) Z(s)≡δeI δeE=C(sI−A)−1B+D (27) In the case that the matrix Ais diagonalizable, finding the inverse of sI−Ais a case of matrix diagonalization. Let Λbe the diagonal matrix similar to A....
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
16
c6eeff53-0e72-4338-9418-3ddadc90c06a
A=PΛP−1(28) (sI−A)−1= sI−PΛP−1−1(29) = P(sI−Λ)P−1−1(30) =P(sI−Λ)−1P−1(31) Pluging this expression into the impedance equation, we can see that the impedance of a system with a diagonalizable connection matrix takes the form of a sum of voigt-like terms, a circuit containing a resistor and capacitor. Z(s) =CP(sI−Λ)−1P...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
17
12ed7e42-b0e7-41d1-bd05-b502146b4762
with the correct choice of inductors, capacitors, and resistors, achieve the same impedance characteristics. From this derivation it is clear that the EIS measurement provides information about the eigenvalues of the underlying system dynamics. If the impedance data can be fit to a model consisting of voigt elements, w...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
17
4571448f-5e15-42b2-92d6-732cdd0d15de
share the same eigenvalues. Therefore, EIS, on its own, cannot be used to determine the reaction mechanism of an arbitrary electrochemical system. EIS can be used to place limits on a proposed reaction mechanism, or provide information about an already known reaction mechanism. 7.2 Impedance Characteristics of Systems ...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
17
9b267f78-ee9c-4378-9ade-30b39fa22084
Jordan canonical form, which is an upper triangular matrix consisting of so-called Jordan blocks along it’s diagonal. The Jordan normal form of a matrix and it’s pseudo eigen vectors is written like A=PJP−1(36) J=diag(Jλ1,n1, . . . ,Jλr,nr) (37) Jλi,ni=λiI+Nni (38) HereNniis the upper shift matrix of dimension ni, a ma...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
18
75430089-56bf-4359-937e-14d9536766fe
j+k(44) Then the total impedance is then the sum of the impedance contribution from each Jordan block. Z(s) =rX i=0ni−1X k=0Ωi,k (s−λi)k+1(45) 7.3 The Impedance of a System With Imaginary Eigenvalues The previous derivation generalizes to imaginary eigenvalues. For a connection matrix con- taining only real coefficient...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
18
81bda9b0-bea1-4a2b-b523-790a398ef72c
Zi(s) =Ω+ s−αi−jβi+Ω− s−αi+jβi(46) =Ω+(s−αi+jβi) + Ω −(s−αi−jβi) (s−αi−jβi) (s−αi+jβi)(47) =(Ω++ Ω−) (s−αi) + (Ω +−Ω−)jβi (s−αi)2+β2 i(48) =Ωre(s−αi) + Ω imjβi s2−2sαi+α2 i+β2 i(49) This impedance response is equivalent to an RLC circuit, a circuit containing a resistor, capacitor, and inductor connected in parallel. 7...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
19
c95a1ec1-2516-40e1-9a4a-c00ff0528690
frequencies. However, this is challenging when using the generalized DRT model, since the integral over ω0in equation 3 spans both positive and negative values. To solve this problem we must separate the integral into the sum of two integrals each integrating over one half of the real axis. After a change of variables ...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
19
a5f101a3-a8ef-41b0-9cd0-4789b3dba5be
γ±(lnω0)≈NX n=1x± nϕn(lnω0) (54) ZgDRT =Rt+Z∞ −∞NX n=1x+ nϕn(lnω0)dlnω0 1 +jω ω0+NX n=1x− nϕn(lnω0)dlnω0 1−jω ω0(55) Using algebraic manipulation and a change of variables, the integral can be separated into a real part and an imaginary part. xre n=x+ n+x− n (56) xim n=x+ n−x− n (57) ZgDRT =Rs+NX n=1xre nZ∞ −∞ϕn(lnω0)d...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
20
0da1cdeb-4201-453e-bc8b-275ca9a85c45
nandxim nusing linear regression. min xre,xim∥ZgDRT−Zexp∥= min xre,xim ∥xreAre−Re(Zexp)∥+∥ximAim−Im(Zexp)∥ (62) 7.5 Normalized Linear Fitting When finding the DRT function from experimental data, a normalization method is required to prevent overfitting. In this study we use a modified Tikhonov regularization, based o...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
20
fe63d278-a04f-4e1a-9263-3445fb585edc
min xre,xim ∥xreAre−Re(Zexp)∥+∥ximAim−Im(Zexp)∥+xreMxreT+ximMximT (63) The matrix Mis calculated by integrating the square of the derivatives of the test func- tions, ϕn(ω0). Calculating the zeroth derivative, i.e. the function itself, is equivalent to standard Tikhonov regularization. The strength of the regularizat...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
21
1a114420-2326-4692-9b33-dc69191174c4
7.6 Basis Function Selection The choice of basis function is quite arbitrary as long as the resulting function space is large enough to approximate the exact solution for the DRT function. However, in practice the basis function has a large impact on the number of parameters required and the level of regularization req...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
21
c7c88502-3776-4002-8773-e89fad1cfb2a
(66) Combining this test function with equation 60 and 61 gives the following expressions for the matrices AreandAim. Are n,m=1 σ√ 2πZ∞ −∞e−lnω0−lnωn σ√ 22 dlnω0 1 +e2(lnωm−lnω0)(67) Aim n,m=1 σ√ 2πZ∞ −∞elnωm−lnω0e−lnω0−lnωn σ√ 22 dlnω0 1 +e2(lnωm−lnω0)(68) These integrals are calculated numerically and used to fin...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
21
2624691d-829e-4b39-8027-6773d4d9f0b4
References [1] Vijay Chouhan et al. “Study on electropolishing conditions for 650 MHz niobium SRF cavity”. In: arXiv preprint arXiv:2208.04424 (2022). [2] Eric Viklund et al. Studies on the Fundamental Mechanisms of Niobium Electropolish- ing. Tech. rep. Fermi National Accelerator Lab.(FNAL), Batavia, IL (United States...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
22
96b7dd61-cc0a-4d74-bebc-8b85e9b63829
Sulfuric Acid Electrolyte”. In: Journal of The Electrochemical Society 155.9 (July 2008), p. D563. doi:10.1149/1.2945913 .url:https://dx.doi.org/10.1149/1. 2945913 . [6] Hui Tian et al. Novel characterization of the electropolishing of niobium with sulfu- ric and hydrofluoric acid mixtures . Tech. rep. Thomas Jefferson...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
22
30b9b935-401c-4f86-8095-20edd9d5b585
_1745355.pdf .url:https://doi.org/10.1063/1.1745355 . [9] Ting Hei Wan et al. “Influence of the discretization methods on the distribution of relaxation times deconvolution: implementing radial basis functions with DRTtools”. In:Electrochimica Acta 184 (2015), pp. 483–499. [10] Yanxiang Zhang et al. “Reconstruction of ...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
22
e555c755-da20-4a62-9080-5aa67aacbc15
trodes”. In: Journal of The Electrochemical Society 155.7 (May 2008), B675. doi: 10.1149/1.2908860 .url:https://dx.doi.org/10.1149/1.2908860 . [12] Helge Schichlein et al. “Deconvolution of electrochemical impedance spectra for the identification of electrode reaction mechanisms in solid oxide fuel cells”. In: Journal ...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
22
eefb9cf7-6c63-4747-b6a4-1bb6ef262f40
[13] A. Leonide et al. “Evaluation and Modeling of the Cell Resistance in Anode-Supported Solid Oxide Fuel Cells”. In: Journal of The Electrochemical Society 155.1 (Nov. 2007), B36. doi:10.1149/1.2801372 .url:https://dx.doi.org/10.1149/1.2801372 . [14] Jan Philipp Schmidt et al. “The distribution of relaxation times as...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
23
25d33bd1-1fc2-4d3a-b4e8-31f1639ec158
2313-0105. doi:10.3390/batteries5020043 .url:https://www.mdpi.com/2313- 0105/5/2/43 . [16] Roby Soni et al. “Lithium-sulfur battery diagnostics through distribution of relaxation times analysis”. In: Energy Storage Materials 51 (2022), pp. 97–107. issn: 2405-8297. doi:https : / / doi . org / 10 . 1016 / j . ensm . 2022...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
23
b2e3b1f0-00f4-4f69-9546-5c0928d780d4
the electropolishing of niobium”. In: Physical Review Special Topics—Accelerators and Beams 13.8 (2010), p. 083502. [19] NW Khun, M Sumption, and GS Frankel. “Smoothening of niobium by electropolish- ing”. In: Journal of Applied Electrochemistry 43 (2013), pp. 829–838. [20] Noam Eliaz and Eliezer Gileadi. Physical elec...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
23
23da0721-0afc-46db-a97a-6f35050c018c
der electrochemical reaction control”. In: Journal of the Electrochemical Society 146.5 (1999), p. 1847. [23] Bernard A. Boukamp and Aur´ elie Rolle. “Analysis and Application of Distribution of Relaxation Times in Solid State Ionics”. In: Solid State Ionics 302 (2017). ISS- FIT12., pp. 12–18. issn: 0167-2738. doi:http...
d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf
23
63638161-a3bf-4a24-afc0-3beb9c6d8c13
Journal Pre-proof Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers used in accelerator Sonal Sharma, Mentes Jose, Gireesh Singh, Rajesh Kumar PII: S0168-9002(24)00955-0 DOI: https://doi.org/10.1016/j.nima.2024.170029 Reference: NIMA 170029 To appear in: Nuclear Inst. a...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
0
35c3cbbf-bc5a-4c03-a2ba-98f7367add98
of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
0
60e78286-4dd4-417f-bbd1-51ba0d4c20d6
1 Title: Design and development of Resonant ring test setup at 325 MHz for high power 1 testing of RF couplers used in accelerator 2 3 Authors and affiliation: Sonal Sharma*, Mentes Jose, Gireesh Singh, Rajesh Kumar 4 *Ph(O):+91 -22-25591475, email id: sonal@barc.gov.in 5 6 Ion Accelerator Development Di...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
1
c4905806-6cc8-43c8-9a04-de160b5e6d31
design, RF simulations and characterization of the entire ring , along with the high power test results , are 14 presented in this paper . 15 16 Keywords : RF couplers, resonant ring , high power, travelling wave, RF s imulation, Directional coupler , 17 waveguides. 18 19 1. Introduction 20 21 The desi...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
1
cf5fa7ae-52b6-4eb2-857b-dfb465e16156
proton accelerator consisting of a normal conducting 3 MeV radio frequency quadrupole (RFQ) , 10 MeV 27 Drift tube Linac (DTL) and a series of superconducting Single Spoke R esonators (SSR) to reach the final 28 energy of 40 MeV. A number of coaxial RF couplers [4,5 ] at frequency of 325 MHz are being fabricated to...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
1
42a08686-a1fe-4904-bbf8-f0aad0d4862a
source and amplify it with certain gain [7,8,9 ,10]. It is also known as a traveling wave resonator in which 35 high power builds up in the ring under certain operating condition s. In this resonant ring , the input power is 36 fed into the ring via a directional coupler [6] continuously leading to development of ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
1
c63f48be-8ae5-4907-b5cb-20f496b100d2
2 NASA [11 ], ILC [ 12], e2V microwave technology center [13], IPR [14 ], IHEP [15], CERN [16], KEK [17] 41 etc. 42 The resonant ring developed at BARC is a WR 2300 half height waveguide based closed structure . The 43 design and simulation of the ring was carried out using CST studio suite [18]. The basic ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
2
d40b9c90-80d2-4307-b7e6-b4d00f5ca3fd
50 2.1 Layout and gain of the resonant ring: 51 52 Fig. 1 shows the basic layout of a resonant ring [7,8]. A r esonant ring consists of a primary line and a 53 secondary loop or ring. A part of the power generated from the RF source in the primary line is coupled to 54 the secondary loop/ring with the help of ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
2
f3d23213-e07d-4725-b17d-e74c6cb140d2
directional coupler , return loss , attenuation in the ring , transmission coefficient and electrical length of the 76 ring [7,8,9]. Once the components of the ring are identified, the insertion loss or attenuation of the ring can 77 be determined by calcu lating losses of all the components . Based on this at...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
2
5724c266-6983-49fd-9f17-c72495ede543
3 In Fig.1, a directional coupler couples power from input to the ring. It is represented as a four port network 80 with ports 1 -4. Port 1 is input port, port 2 is the through port, port 3 is the coupled port and port 4 is the 81 isolated port. The forward wave is represented as ‘a n’ and the reverse wave is re...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
3
afd2a85e-7b61-4428-8665-4d8e523407b4
87 where, C is the voltage coupling coefficient of the directional coupler [1 9,20] which couples power from 88 main line to the ring (C is the ratio of voltage at the coupled port to the voltage at the input port and it is not 89 in dB ), γ is the propagation constant ( γ =α+jβ), α is the attenuation constant, ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
3
33840373-f082-472a-aaa2-08f43304c744
|1−Te−jβl √(1−C2)|2 −−−−(4) 97 where, T is the transmission coefficient (it is not in dB) and accounts for the attenuation in the circuit 98 (attenuation = e−αl ). When the ring is in resonance, βl will be an integral number of 2π and the e−jβl phase 99 shift term will d...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
3
e593b2f9-4efa-4369-aa1e-2a2214e2e4b0
a3=T2∗r∗b3+√(1−r2)∗T∗b4 −−−−(7) 105 b4=√(1−C2)∗a3 −−−−(8) 106 a4=T2∗r∗b4+√(1−r2)∗T∗b3 −−−−(9) 107 Rearranging equati...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
3
7b832714-582b-4368-8f3b-4dfc0b288959
4 It is evide nt from equations 4 and 10 that in order to maximize the gain, attenuation and reflections should 112 be kept to minimum. All the components of the ring structure are designed accordingly. Theoretically 113 calculated attenuation for aluminium WR 2300 waveguides used in our ring is 0.0 7 dB in one t...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
4
1eab253d-bfe1-4e58-994e-0cd02250e6f2
(assuming there are no reflection s in the ring ). It is observed that for 0.4 dB attenuation ( with couplers ), the 119 gain is maximum at coupling of about 11 dB (corresponding to this power gain is 11.3 times) . For 13 dB 120 coupling , the gain obtained is very close to this value (10.45 times). Practically,...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
4
7f8ad2c2-4ca9-4208-a3d1-19d49514fe46
considerable power gain . 130 131 132 05101520253035 8 10 11 12 13 14 15 16 18 20 22Power gain Coupling (dB)attenuation 0.14 dB attenuation 0.4 dB 05101520253035 0.001 0.002 0.005 0.01 0.02 0.05Power gain reflection coefficient (r)Fig. 2: Variation of ring g ain with coupling coefficient Fig. 3: Variation of ri...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
4
691eb969-9cfb-4691-8c28-a015cf5586ec
5 2.2 Power buildup in the ring: 133 134 The p ower buildup in the ring is illustrated in Fig. 4. Four stages are shown in this Figure. Fig. 4(a) shows 135 the input power , marked as red arrow , incident on the input port of directional coupler . Fig. 4(b) shows that 136 a part of this power is coupled to the ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
5
d70d788b-01ad-4cba-9772-6c7c9ac10232
as green arrows in Fig. 4(d). The b igger green arrow in the resonant ring indicates increase in power and 142 smaller green arrow at the load indicates reduction in power at the load. 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
5
c3312086-ac38-4f71-8cdc-543d72671a89
6 Fig. 5 shows the transient behavior of the ring . In th is figure, Vin is the input voltage and Vring is the 173 voltage in the ring . The voltage inside the resonant ring increases with time due to phase addition of the 174 waves. This process continues till the steady state is reached. At steady state , th...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
6
c193a956-af36-4def-8833-b68b769ec1b2
both the cases and the filling equations of the cavity will apply to the resonant ring structure. If the steady 184 state voltage in the ring is Vo, the equation representing the transient behavior of the ring is given as , 185 Vring =Vo (1−e−t τ) ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
6
e71bf4e8-431b-49ef-9fa1-8340254e0b40
QL=fo ∆𝑓 −−−−(13) 193 194 where, Δf is the 3 dB bandwidth of the resonant ring , which can be determined from gain vs frequency 195 plot of the ring. 196 197 198 199 00.511.522.533.544.555.566.577.5 0 2 4 6 8 10 12 14 16 18 20 22 24Voltage (V) time μsVin...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
6
aa3ae3ea-f3ee-4d77-84bb-b5b07fab4674
7 3. Design details of the ring setup 200 201 The design of the resonant ring depends on the required power gain , frequency of operation, power level etc . 202 It requires a number of components for its operation. The actual ring setup in our lab consists of a RF source 203 of 3 kW @325 MHz [21], primary ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
7
2fdfb5fb-13b4-476f-ab15-c46d6962a5de
done without RF couplers . Later on , two RF couplers with a cavity will be added for testing. This cavity will 210 act as a transmission cavity between both the couplers. 211 212 213 214 215 216 217 218 219 220 221 222 223 2...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
7
99386656-09bd-4d25-83f9-227f006f4679
8 3.1 Directional coupler (13 dB): 239 240 This dual directional coupler is required to coupler RF power from primary line (waveguide section with 241 ports 1 and 2) to the secondary line (waveguide section with ports 3 and 4). The secondary line will be part 242 of the resonant ring. As discussed in section...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
8
a25b78c5-214c-461f-99bd-cd91a81d527a
practically achievable. The theory of this directional coupler is based on two hole couplers parted at a distance 248 of λg/4. The CST model of the coupler and its cut plane view are given in Fig. 7(a) and 7( b) respectively . 249 250 251 252 253 254 255 256 257 258 259 260 261 262 26...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
8
72e3dad9-c4e7-421b-8faf-41170dff9c3a
changing these values. Once coupling is finalized , the radius of holes is kept constant and the parameter ‘s’ 273 is varied to get maximum isolation and directivity. The effect of changing the paramet er ‘s’ to obtain best 274 isolation ( which is determined by S31) for a fixed frequency is shown in F ig. 8. Maxi...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
8
1b59f9e7-ee4d-4038-8afe-1ff73b511765
9 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 Fabricated directional coupler is shown in Fig . 9. Low level characterization of the directional coupler 295 was done on vector network analyser ( VNA ). The comparison of the designed, simulated and measured 296...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
9
d41cd4f1-0de3-4293-987e-9458cceb3267
value ( dB) Measured value (dB) 1 Return loss S11 >25 57 26.2 2 Insertion loss S21 < 0.5 0.19 0.3 3 Coupling (C) S31 13 13.5 13.1 4 Isolation (I) S41 > 38 68 38.1 5 Directivity (D =I -C)) S34 > 25 54.5 25.3 Table 1 : Parameters of 13 dB directional coupler Port 2 Port 1 Port 3...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
9
fc5ca89b-3708-4b96-a8b9-ce7f5895e38a
10 The RF power coupled in the resonant ring increases to the desired level in short time. To monitor this power 305 a half height waveguide based loop type of directional coupler [22] was developed providing coupling of 50 306 dB and directivity better than 30 dB. This directional coupler is part of the seco...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
10
339113c6-6acc-4c72-9577-9b0bb898ca99
318 319 320 321 3.3. Waveguide tuners and H bends 322 323 For resonance at desired frequency, it is required that the total length of the ring should be integral multiple 324 of guided wavelength. In order to have frequency tuning, waveguide tuners [4] are used in the ring . The 325 tuners are cylindr...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
10
9d73707e-f14c-469f-b118-697fdb691cfa
S.n o Parameter S-parameter Designed value (dB) CST simulation value ( dB) Measured value (dB) 1 Return loss S11 >25 53 28.2 2 Insertion loss S21 < 0.05 0.0005 0.02 3 Coupling (C) S31 50 51.5 50.5 4 Isolation (I) S41 > 75 86 80.6 5 Directivity (D =I -C)) S34 > 25 34.5 30.5 Table 2: Par...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
10
33628302-6590-416b-a08a-26274dd0d680
11 The secondary line of resonant ring structure needs to be in closed . This is required so that the wave can 331 travel back to the directional couple r and gets added in phase with the incoming wave for amplification. To 332 get the closed loop s tructure four waveguide H bends (90 degree) have been fabricat...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
11
81301586-7ca3-48b0-a3ec-e470a3941973
These are matched individually to get very low reflection in the ring . 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 Fig. 12: CST model of resonant ring Waveguide bend Loop type directional coupler Primary line directional coupler W...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
11
53979185-ae3b-46c9-ad00-3dc39e127c51
12 4.1 Gain and travelling wave in the ring 365 366 The tuner lengths in the resonant ring were varied to get the resonance at 325 MHz . The S 31 parameter , with 367 port 1 at input of 13 dB directional coupler and port 3 at the coupled port of loop type directional coupler in 368 the ring, gives the info...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
12
d64e278c-5fcc-42a6-9450-705e689fede6
round is about 0.02 dB. As ideal components are taken for simulation, these loses are low as compared to the 377 estimated value obtained in section 2.1. The theoretical power gain obtained from equation 3 (for coupling 378 value of 13 dB and attenuation of 0.02 dB) is about 65.7 times, which is close to the gain ob...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
12
cd13d701-3eab-426a-afa6-d05923d897e3
12 and 13, the time constant obtained is 2.27μs. 389 During simulation , the e lectric field in the ring was also monitored. The 3 D electric field run show ed that 390 the field is continuously moving in one direction, indicating the travelling wave characteristic of the r esonant 391 ring. 392 393 -80-70-60-5...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
12
4f531ef4-0046-475f-92df-00b859a89ade
13 RF Characterization and high power testing 394 395 Presently, RF power coupler development is going on at BARC. In order to study the resonant ring behavior, 396 it was closed with WR 2300 half height waveguide lines (without RF couplers ) and characterized using a 397 VNA . High power testing of the ring h...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
13
846b1bc6-a6f2-4931-b52c-cb7e3efb84d8
ring was connected to the other port of VNA. The parameter S 31 gave information about the gain in the ring. 406 The tuners were optimized to get maximum gain at 325 MHz. S 31 obtained on VNA was -36 dB indicating a 407 gain of 14.5 dB (50.5 dB-36 dB) at 325 MHz. 408 The comparison between the simulated and mea...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
13
416add33-9269-475b-8e6f-a4025e6ad7f9
14 421 (a) (b) 422 423 424 From S31 vs frequency plot of Fig. 15 (b) (measured), the 3 dB bandwidth obtained is Δf=0.18 MHz. So, 425 the loaded quality factor from equation 13 is: 426 QL=fo ∆f=325 0.18 427 QL=1805 428 So...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
14
61cfe0fd-1758-42c9-9e33-d11e5b95fc74
used between the signal generator and the ring to observe the input signal on one of the channels of the 442 oscilloscope. T he output signal from the loop type directional coupler was observed on the other channel of 443 the oscilloscope . This is shown in Fig. 16. 444 445 -70-65-60-55-50-45-40-35-30-25 300 30...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
14
808bbada-1431-48d4-a439-cb270df437e8
15 446 447 448 In Fig. 16, Vring is the voltage in the ring and V in is the input voltage. At t=20 μs, the input was switched 449 off. The time constant is the time taken by the ring to reduce to 1/e of its stead y state voltag e. In this case it 450 is 1.9 μs. Comparison of the simulated and measured value...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
15
536eb156-f637-4675-b0b8-ec3419b18ab9
amplifier against any reflections from the ring. Water cooling has been provided to the circulator load and 461 the RF load connected at port 2 of 13 dB directional coupler. Temperature sensors have been used at these 462 two loads to monitor the temperatures during full power operation. 463 0123456 01234567891...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
15
65e0025e-a20d-4664-a1d4-9fde5f4ec04f
16 464 465 466 After full integration of all components, the input power was slowly increased and the output power was 467 observed from the secondary loop type directional coupler in the ring. After optimization, the final power of 468 30.5 kW was obtained in the ring with the input of 1.1 kW. 469 All the ...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
16
81593e3e-7300-446f-8f61-bfb076a8a64a
481 482 483 484 485 486 487 488 S no parameter value 1 Input power 1.1 kW 2 Power in the ring 30.5 kW 3 Resonant f requency of the ring 325.12 MHz 4 Gain 14.4 dB 5 Bandwidth 200 kHz Fig. 17: Resonant ring setup for high power testing Circulator Coaxial transmission line Pr...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
16
4ebfb30e-bb2d-4632-aa96-c0431fda3f81
17 489 490 491 492 6. Conclusion 493 494 A travelling wave resonant ring has been set up at BARC for testing high power RF couplers. Design 495 simulations of the individual RF components and the entire ring was carried out using CST Microwave 496 Studio. After fabrication , RF components were i...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
17
7c300086-b795-4bf8-beb6-d5c047758f9c
with RF power couplers in future. It is also planned to raise the ring power by increasing the input power for 502 testing other waveguide components (like waveguide windows, ridge waveguide couplers etc.). 503 504 7.Acknowledgement 505 506 The authors would like to acknowledge the support for ring assembly...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
17
144953dd-dd8e-4dcb-844b-4df4bef64d39
18 [2] Abhishek Pathak, Shweta Roy, SVLS Rao, and Srinivas Krishnagopal, “Design study for medium 515 energy high intensity proton accelerator”, Phys. Rev. Accel. Beams 23, 090101< 516 https://journals.aps.org/prab/abstract/10.1103/PhysRevAccelBeams.23.090101 >. 517 [3] U. D. Malshe, “Low Energy High Intensity Pr...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
18
8a5b763c-8399-45e3-bbb2-db1ac9c700ca
[7] H. Buttig et.al. , “Study of the ELBE RF -couplers with a new 1.3 GHz RF -coupler test bench driven 525 by a resonant ring”, Nuclear Instruments and Methods A 612 (2010) 427 -437, 526 <https://doi.org/10.1016/j.nima.2009.10. 148>. 527 [8] V. Veshcherevich, Resonant Ring for high power test of RF Couplers”, htt...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
18
27d1a58a-35a1-4a63-abbd-16108474fe3c
March 1988. 535 [12] B.T. DU et.al. , “L-band Resonant Ring for Testing RF Windows for ILC ”, http://www - 536 linac.kek.jp/linac -paper/2 018/linac18 -du-resonantring.pdf . 537 [13] Keith Newsome et. al., “Resonant ring structures for testing high power low loss components ”, 538 https://www.armms.org/media/up...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
18
f7b70f6a-294e-40ff-9a5b-bc7ca8115557
[16] U. Iriso,1 F. Caspers,1 J -M. Laurent,1 and A. Mostacci2, “Traveling wave resonant ring for electron 545 cloud studies”, DOI: 10.1103/PhysRevSTAB.7.073501. 546 [17] B.T. DU et.al., “High power operation of an L-band resonant ring” , Proceedings of the 16th Annual 547 Meeting of Particle Accelerator Society o...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
18
d93c3816-2f56-4f37-8674-4f850a35d77d
19 [21] Patel Niranjan et. al., “Design and development of tetrode based 325 MHz, 3 KW radio frequency 554 (RF) system (pulsed and CW) for ring resonator”, Proceedings of the eighth DAE -BRNS Indian 555 particle accelerator conference -2018 , p. 996 -998. 556 [22] R.F. Schwarf et . al., “Criteria for the design of...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
19
fa122ff0-7fc0-4dc4-9ad3-30a50448c7f9
Declaration of interests ☒ The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. ☐ The authors declare the following financial interests/personal relationships which may be considered as pote...
d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf
20
0f4ca082-ca5d-4759-be54-59d90c10e884
Journal of Instrumentation       PAPER Development and tests of the 499.8 MHz srf cryomodules for HEPS To cite this article: Hongjuan Zheng et al 2024 JINST 19 P10031   View the article online for updates and enhancements. You may also like The high level applications for the HEPS Linac Y.-L. Zhao, H.-F. Ji, X.-H....
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
0
51e1d298-3a3c-47bd-8afc-fd59084e2b26
2024 JINST 19 P10031 P/u.sc/b.sc/l.sc/i.sc/s.sc/h.sc/e.sc/d.sc /b.sc/y.sc IOP P/u.sc/b.sc/l.sc/i.sc/s.sc/h.sc/i.sc/n.sc/g.sc /f.sc/o.sc/r.sc S/i.sc/s.sc/s.sc/a.sc M/e.sc/d.sc/i.sc/a.sc/l.sc/a.sc/b.scReceived: September 29, 2024 Accepted: October 9, 2024 Published: October 29, 2024 Development and tests of the 499.8 MHz...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
1
0c4325b6-e6b9-423a-a3f7-36105c14d019
19B Yuquan Road, Beijing 100049, China 𝑐School of Nuclear Sciences and Technology, University of Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, China E-mail: zhangpei@ihep.ac.cn, maqiang@ihep.ac.cn Abstract: A 499.8MHz single-cell superconducting cavity has been proposed as the active third- harmonic cavi...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
1
ee85b2f2-a8d9-4be3-a1ed-97a9d7a7ec5f
clean-assembly procedure was developed, resulting in excellent rf performance maintained from verticalteststohorizontaltestsatcryogenictemperatures. Theunloadedqualityfactorsofallthree modules exceeded 2.45×109at 1.75MV, significantly surpassing the design goal. No field emissions wereobservedthroughoutthetests. Thesea...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
1
41e9bc06-2a46-49f3-a8ce-165518d14056
presents the design, fabrication, assembly, cryogenic tests, and transportation of the mechanically improved 499.8MHz single-cell srf cryomodule. Keywords: Acceleration cavities and superconducting magnets (high-temperature superconductor, radiation hardened magnets, normal-conducting, permanent magnet devices, wiggler...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
1
6fe18416-a5eb-428f-a934-5e2b0497c656
2024 JINST 19 P10031Contents 1 Introduction 1 2 Cavity system 3 2.1 RF design 3 2.2 Mechanical design 4 2.3 Cavity fabrication, surface preparation and rf testing 5 2.4 Higher order modes 8 2.5 Synchrotron light irradiation 8 3 Cryomodule assembly and integration 9 4 Horizontal tests 10 4.1 Warm conditioning 10 4.2 Coo...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
2
0273e5c8-0a1f-4e88-b8b7-6a8af7ec8481
of34pm·rad,promisingaradiationbrightnessof 5×1022photons/s/mm2/mrad2/(0.1%bandwidth) inthetypicalhardX-rayregime. Thestoragering,withacircumferenceof1360.4m,operatesata beamcurrentof200mA.Adouble-frequencyradiofrequency(rf)systemwasemployedtoenablea novelbeaminjectionschemeknownason-axisaccumulationinjection,initiallyd...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
2
25df8372-7bf4-437d-8dee-65f9a7995efd
shown in figure 1. It is important to note that the third-harmonic rf is active rather than passive. HEPSrequiresheavydampingofhigherordermodes(HOMs),leadingtotheadoptionofasingle- cell cavity design with beam-pipe absorbers [ 6]. The established KEKB-type single-cell elliptical geometrywasselected[ 7]. The499.8MHzcavi...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
2
31f70818-95e9-4e03-b91e-bef7132460ae
2024 JINST 19 P10031 Figure 1. Layout of the HEPS rf system. reinforcement schemewas developed, incorporatingincreased cavitywall thickness andtwo on-cell stiffeningringstoensurecompliancewithpressurevesselcodesunderdifferentworkingconditions. As a synergy between HEPS and BEPCII Upgrade (BII-U) [ 10], the cryomodule d...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
3
d3807c47-325a-4b13-8047-92c6c81db1b2
a maximum of 3.5MV rf voltage and 400kW of beam power, with an rf voltage of 0.91MV required for bunch lengthening, absorbing 104.3kW of power from the beam. The substantial margin in the rf parameters is reserved for future implementation of the on-axis accumulation injection scheme. Figure 2. Cryomodules of HEPS and ...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
3
7d7c30b2-b883-4084-ba4d-f0fabbea1293
2024 JINST 19 P10031Three 499.8MHz cryomodules were developed, with two designated for HEPS and one for BEPCII-U, and underwent high-power testing at the horizontal test stand at the Platform of Advanced Photon Source Technology R&D (PAPS). All three modules demonstrated excellent performance. Subsequently,onemodulewas...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
4
e1343655-7e8e-4501-b93b-31ffc49fa900
process. Thevacuumlevelandcryogenicperformancewerenicelymaintainedfollowingtherelocation. The module has been accelerating the electron beam at HEPS since August 2024. Thispaperdetailsthedesign,integration,andperformancetestingofthe499.8MHzcryomodules. Additionally, the transportation oftwo modules, over short andlong ...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
4
7adff110-2c4c-4a4b-a213-f877ae69839a
onbothendswerechosentoallowallHOMstoexitthecellandsubsequentlybeattenuatedbythe beam-line absorbers at room temperature [ 12]. The main parameters of the cavity are listed in table 1. Figure 3. (a) Cavity rf geometry, (b) electric and (c) magnetic field distributions of the accelerating mode (normalized to a stored ene...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
4
e507819a-e77b-4dbd-89e3-5c1756c27e1d
2024 JINST 19 P10031Table 1.Main parameters of the 499.8MHz cavity. “LBP” stands for large beam pipe, “SBP” stands for small beam pipe, “VT” stands for vertical test. Parameter Value Unit Resonant frequency 499.8 MHz Cavity length (flange to flange) 961 mm Accelerating gap 266.5 mm Iris diameter 220 mm LBP diameter 300...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
5
e7d8db13-5938-42c2-b17f-45d57f527822
Lorentz coefficient Hz/(MV/m)2−5.4 Buckling critical factor - 30.2 2.2 Mechanical design TheoriginalKEKBcavitywasmadeofpureniobiumsheetsof2.5mm,witharesidualresistanceratio (RRR) of 200 [ 7]. The cavity was fabricated by using the spinning method, and the wall thickness variedfrom1.8to2.7mm. However,thislimitedtheopera...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
5
e8e9512a-a363-4801-8516-bc467ecd0bba
wasspecifiedas2baratroomtemperature(293K).Apairofstiffeningringswereaddedtothecell to prevent collapse due to buckling under various working loads. The peak stress reads 76MPa located on the iris of the dressed cavity, which marginally exceeds thepermissiblevalueof 70.5MPa fordiscontinuitiesunderMAWPatroomtemperature. ...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
5
cbe10b8b-66ea-428f-b3e6-fe1dca4ae176
2024 JINST 19 P10031 Figure 4. (a) Stress and (b) deformation of the dressed cavity under 2bar external pressure. Thecavity’stuningsensitivityis346.1kHz/mm,withastiffnessof12.5kN/mm. Thetuningrange, determined by the allowed peak stress, is ±219kHz at room temperature. The pressure sensitivity is−4.2Hz/mbar with both b...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
6
a26608d5-09e2-4982-b64f-6a205b7714bb
Mechanical resonances induced by external vibrations in the cavities of a cryomodule can impacttheresonantfrequency,leadingtoinstabilities. Amodalanalysiswasperformedtoexamine the cavity’s natural vibration, revealing that longitudinal modes pose the greatest risk of causing frequency detuning. The frequency of the low...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
6
62f5e065-46ef-4bc6-af32-34ba88a4ebde
2024 JINST 19 P10031largebeamtubeandthetransitionpipe. Theinnersurfacesofthecavitieswerecarefullyinspectedand ground,ifnecessary,beforeeachweldingsteptopreventdefects. Followingfabrication,astandard post-processingprocedureforsuperconductingcavitieswasfollowed[ 14,15]. Thecavitieswerefirstly degreased in an ultrasonic ...
d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf
7