id stringlengths 36 36 | text stringlengths 1 1k | source stringlengths 42 191 | page int64 0 1.03k |
|---|---|---|---|
73c3c3a0-575c-40d6-b3ab-798612184cd3 | current and complex geometry of the cavity and cathode. Currently, cavity electropolishing
machines do not employ a reference electrode and instead only set a fixed voltage between
the anode and cathode. This means that cathode losses and ohmic losses in the electrolyte
can significantly alter the polishing potential a... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 12 |
6de968eb-7f34-451b-af2e-504883e47231 | information can be used to tweak the EP parameters such as voltage and temperature to
ensure that the cavity is in an optimal polishing regime. This technique may be useful when
electropolishing complex cavity geometries such as quarter-wave and half-wave geometries.
13 | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 12 |
e16f8d26-8787-4094-974d-7d21418e9d05 | Figure 5: The Distribution of relaxation times calculated from the EIS impedance data
for each of the measured potentials. The current-voltage curve is shown in the graph on
the left. The left DRT plot shows eigenvalues that are less than zero, which correspond to
stable eigenvalues. The right DRT plot shows eigenvalue... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 13 |
17e02221-d556-4e37-8b88-0cd12974b657 | NbS0NbOS1
k10k01
Nb2O5
S2k21k12 NbsolS3k13
k23
Figure 6: Proposed mechanism for niobium electropolishing in HF-containing electrolyte by
a two step oxidation reaction.
Figure 7: The surface height maps of Nb samples electropolished at different voltages and
temperatures.
15 | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 14 |
1708afc5-b136-44c6-9c6e-1f1317726826 | 5 Conclusion
In this study we find evidence that the etching phenomenon seen in electropolished SRF
cavities is caused by insufficient polishing voltage and investigate the mechanism behind it.
Niobium polished below a critical voltage will experience etching whereas niobium polished
above this voltage will experience ... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 15 |
4a9995fa-c0de-41ef-a12e-97d11da16f72 | most likely caused by the oxide film which forms when HF is depleted near the niobium
surface and the oxidation rate exceeds the rate of dissolution by HF.
6 Acknowledgements
The authors would like to thank Dr. Noam Eliaz and Dr. Eyal Sabatani for their insightful
discussions and recommendations during the authoring of... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 15 |
51f70310-5aa9-4783-b0ee-57f280f0aec4 | merical techniques used in this paper including the derivation of the first order and higher or-
der impedance response of linear systems and the derivation of the generalized DRT method.
The details of calculating the DRT of Nb EP to produce figure 5, such as chosing the basis
functions and normalization parameters, i... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 15 |
944ffccf-9bad-48f0-a1a3-2419163caac3 | For a system that satisfies the above mentioned stability condition, the non-linear system
of equations can be linearized near its stable point using a first order Taylor expansion,
written in matrix notation as shown below.
⃗P=⃗P0+δ⃗P (13)
E=E0+δE (14)
I=I0+δI (15)
dδ⃗P
dt=Aδ⃗P+BδE (16)
δI=Cδ⃗P+DδE (17)
(A)i,j≡Ai,j=∂... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 16 |
7b57d78d-5d20-444f-8ba0-4a3784121d6e | potential in the Laplace domain.
eX≡L(X) (22)
sδeP=AδeP+BδeE (23)
δeP= (sI−A)−1BδeE (24)
δeI=CδeP+DδeE (25)
δeI=C(sI−A)−1BδeE+DδeE (26)
Z(s)≡δeI
δeE=C(sI−A)−1B+D (27)
In the case that the matrix Ais diagonalizable, finding the inverse of sI−Ais a case of
matrix diagonalization. Let Λbe the diagonal matrix similar to A.... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 16 |
c6eeff53-0e72-4338-9418-3ddadc90c06a | A=PΛP−1(28)
(sI−A)−1=
sI−PΛP−1−1(29)
=
P(sI−Λ)P−1−1(30)
=P(sI−Λ)−1P−1(31)
Pluging this expression into the impedance equation, we can see that the impedance of a
system with a diagonalizable connection matrix takes the form of a sum of voigt-like terms,
a circuit containing a resistor and capacitor.
Z(s) =CP(sI−Λ)−1P... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 17 |
12ed7e42-b0e7-41d1-bd05-b502146b4762 | with the correct choice of inductors, capacitors, and resistors, achieve the same impedance
characteristics.
From this derivation it is clear that the EIS measurement provides information about the
eigenvalues of the underlying system dynamics. If the impedance data can be fit to a model
consisting of voigt elements, w... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 17 |
4571448f-5e15-42b2-92d6-732cdd0d15de | share the same eigenvalues. Therefore, EIS, on its own, cannot be used to determine the
reaction mechanism of an arbitrary electrochemical system. EIS can be used to place limits
on a proposed reaction mechanism, or provide information about an already known reaction
mechanism.
7.2 Impedance Characteristics of Systems ... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 17 |
9b267f78-ee9c-4378-9ade-30b39fa22084 | Jordan canonical form, which is an upper triangular matrix consisting of so-called Jordan
blocks along it’s diagonal. The Jordan normal form of a matrix and it’s pseudo eigen vectors
is written like
A=PJP−1(36)
J=diag(Jλ1,n1, . . . ,Jλr,nr) (37)
Jλi,ni=λiI+Nni (38)
HereNniis the upper shift matrix of dimension ni, a ma... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 18 |
75430089-56bf-4359-937e-14d9536766fe | j+k(44)
Then the total impedance is then the sum of the impedance contribution from each
Jordan block.
Z(s) =rX
i=0ni−1X
k=0Ωi,k
(s−λi)k+1(45)
7.3 The Impedance of a System With Imaginary Eigenvalues
The previous derivation generalizes to imaginary eigenvalues. For a connection matrix con-
taining only real coefficient... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 18 |
81bda9b0-bea1-4a2b-b523-790a398ef72c | Zi(s) =Ω+
s−αi−jβi+Ω−
s−αi+jβi(46)
=Ω+(s−αi+jβi) + Ω −(s−αi−jβi)
(s−αi−jβi) (s−αi+jβi)(47)
=(Ω++ Ω−) (s−αi) + (Ω +−Ω−)jβi
(s−αi)2+β2
i(48)
=Ωre(s−αi) + Ω imjβi
s2−2sαi+α2
i+β2
i(49)
This impedance response is equivalent to an RLC circuit, a circuit containing a resistor,
capacitor, and inductor connected in parallel.
7... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 19 |
c95a1ec1-2516-40e1-9a4a-c00ff0528690 | frequencies. However, this is challenging when using the generalized DRT model, since the
integral over ω0in equation 3 spans both positive and negative values. To solve this problem
we must separate the integral into the sum of two integrals each integrating over one half of
the real axis. After a change of variables ... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 19 |
a5f101a3-a8ef-41b0-9cd0-4789b3dba5be | γ±(lnω0)≈NX
n=1x±
nϕn(lnω0) (54)
ZgDRT =Rt+Z∞
−∞NX
n=1x+
nϕn(lnω0)dlnω0
1 +jω
ω0+NX
n=1x−
nϕn(lnω0)dlnω0
1−jω
ω0(55)
Using algebraic manipulation and a change of variables, the integral can be separated
into a real part and an imaginary part.
xre
n=x+
n+x−
n (56)
xim
n=x+
n−x−
n (57)
ZgDRT =Rs+NX
n=1xre
nZ∞
−∞ϕn(lnω0)d... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 20 |
0da1cdeb-4201-453e-bc8b-275ca9a85c45 | nandxim
nusing linear regression.
min
xre,xim∥ZgDRT−Zexp∥= min
xre,xim
∥xreAre−Re(Zexp)∥+∥ximAim−Im(Zexp)∥
(62)
7.5 Normalized Linear Fitting
When finding the DRT function from experimental data, a normalization method is required
to prevent overfitting. In this study we use a modified Tikhonov regularization, based o... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 20 |
fe63d278-a04f-4e1a-9263-3445fb585edc | min
xre,xim
∥xreAre−Re(Zexp)∥+∥ximAim−Im(Zexp)∥+xreMxreT+ximMximT
(63)
The matrix Mis calculated by integrating the square of the derivatives of the test func-
tions, ϕn(ω0). Calculating the zeroth derivative, i.e. the function itself, is equivalent to
standard Tikhonov regularization. The strength of the regularizat... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 21 |
1a114420-2326-4692-9b33-dc69191174c4 | 7.6 Basis Function Selection
The choice of basis function is quite arbitrary as long as the resulting function space is large
enough to approximate the exact solution for the DRT function. However, in practice the
basis function has a large impact on the number of parameters required and the level of
regularization req... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 21 |
c7c88502-3776-4002-8773-e89fad1cfb2a | (66)
Combining this test function with equation 60 and 61 gives the following expressions for
the matrices AreandAim.
Are
n,m=1
σ√
2πZ∞
−∞e−lnω0−lnωn
σ√
22
dlnω0
1 +e2(lnωm−lnω0)(67)
Aim
n,m=1
σ√
2πZ∞
−∞elnωm−lnω0e−lnω0−lnωn
σ√
22
dlnω0
1 +e2(lnωm−lnω0)(68)
These integrals are calculated numerically and used to fin... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 21 |
2624691d-829e-4b39-8027-6773d4d9f0b4 | References
[1] Vijay Chouhan et al. “Study on electropolishing conditions for 650 MHz niobium SRF
cavity”. In: arXiv preprint arXiv:2208.04424 (2022).
[2] Eric Viklund et al. Studies on the Fundamental Mechanisms of Niobium Electropolish-
ing. Tech. rep. Fermi National Accelerator Lab.(FNAL), Batavia, IL (United States... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 22 |
96b7dd61-cc0a-4d74-bebc-8b85e9b63829 | Sulfuric Acid Electrolyte”. In: Journal of The Electrochemical Society 155.9 (July
2008), p. D563. doi:10.1149/1.2945913 .url:https://dx.doi.org/10.1149/1.
2945913 .
[6] Hui Tian et al. Novel characterization of the electropolishing of niobium with sulfu-
ric and hydrofluoric acid mixtures . Tech. rep. Thomas Jefferson... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 22 |
30b9b935-401c-4f86-8095-20edd9d5b585 | _1745355.pdf .url:https://doi.org/10.1063/1.1745355 .
[9] Ting Hei Wan et al. “Influence of the discretization methods on the distribution of
relaxation times deconvolution: implementing radial basis functions with DRTtools”.
In:Electrochimica Acta 184 (2015), pp. 483–499.
[10] Yanxiang Zhang et al. “Reconstruction of ... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 22 |
e555c755-da20-4a62-9080-5aa67aacbc15 | trodes”. In: Journal of The Electrochemical Society 155.7 (May 2008), B675. doi:
10.1149/1.2908860 .url:https://dx.doi.org/10.1149/1.2908860 .
[12] Helge Schichlein et al. “Deconvolution of electrochemical impedance spectra for the
identification of electrode reaction mechanisms in solid oxide fuel cells”. In: Journal ... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 22 |
eefb9cf7-6c63-4747-b6a4-1bb6ef262f40 | [13] A. Leonide et al. “Evaluation and Modeling of the Cell Resistance in Anode-Supported
Solid Oxide Fuel Cells”. In: Journal of The Electrochemical Society 155.1 (Nov. 2007),
B36. doi:10.1149/1.2801372 .url:https://dx.doi.org/10.1149/1.2801372 .
[14] Jan Philipp Schmidt et al. “The distribution of relaxation times as... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 23 |
25d33bd1-1fc2-4d3a-b4e8-31f1639ec158 | 2313-0105. doi:10.3390/batteries5020043 .url:https://www.mdpi.com/2313-
0105/5/2/43 .
[16] Roby Soni et al. “Lithium-sulfur battery diagnostics through distribution of relaxation
times analysis”. In: Energy Storage Materials 51 (2022), pp. 97–107. issn: 2405-8297.
doi:https : / / doi . org / 10 . 1016 / j . ensm . 2022... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 23 |
b2e3b1f0-00f4-4f69-9546-5c0928d780d4 | the electropolishing of niobium”. In: Physical Review Special Topics—Accelerators and
Beams 13.8 (2010), p. 083502.
[19] NW Khun, M Sumption, and GS Frankel. “Smoothening of niobium by electropolish-
ing”. In: Journal of Applied Electrochemistry 43 (2013), pp. 829–838.
[20] Noam Eliaz and Eliezer Gileadi. Physical elec... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 23 |
23da0721-0afc-46db-a97a-6f35050c018c | der electrochemical reaction control”. In: Journal of the Electrochemical Society 146.5
(1999), p. 1847.
[23] Bernard A. Boukamp and Aur´ elie Rolle. “Analysis and Application of Distribution
of Relaxation Times in Solid State Ionics”. In: Solid State Ionics 302 (2017). ISS-
FIT12., pp. 12–18. issn: 0167-2738. doi:http... | d:\Zotero\sync\storage\ZQHWFPKE\Viklund 等 - 2025 - Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method.pdf | 23 |
63638161-a3bf-4a24-afc0-3beb9c6d8c13 | Journal Pre-proof
Design and development of Resonant ring test setup at 325 MHz for high power
testing of RF couplers used in accelerator
Sonal Sharma, Mentes Jose, Gireesh Singh, Rajesh Kumar
PII: S0168-9002(24)00955-0
DOI: https://doi.org/10.1016/j.nima.2024.170029
Reference: NIMA 170029
To appear in: Nuclear Inst. a... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 0 |
35c3cbbf-bc5a-4c03-a2ba-98f7367add98 | of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of
record. This version will undergo additional copyediting, typesetting and review before it is published
in its final form, but we are providing this version to give early visibility of the article. Please note that... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 0 |
60e78286-4dd4-417f-bbd1-51ba0d4c20d6 | 1
Title: Design and development of Resonant ring test setup at 325 MHz for high power 1
testing of RF couplers used in accelerator 2
3
Authors and affiliation: Sonal Sharma*, Mentes Jose, Gireesh Singh, Rajesh Kumar 4
*Ph(O):+91 -22-25591475, email id: sonal@barc.gov.in 5
6
Ion Accelerator Development Di... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 1 |
c4905806-6cc8-43c8-9a04-de160b5e6d31 | design, RF simulations and characterization of the entire ring , along with the high power test results , are 14
presented in this paper . 15
16
Keywords : RF couplers, resonant ring , high power, travelling wave, RF s imulation, Directional coupler , 17
waveguides. 18
19
1. Introduction 20
21
The desi... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 1 |
cf5fa7ae-52b6-4eb2-857b-dfb465e16156 | proton accelerator consisting of a normal conducting 3 MeV radio frequency quadrupole (RFQ) , 10 MeV 27
Drift tube Linac (DTL) and a series of superconducting Single Spoke R esonators (SSR) to reach the final 28
energy of 40 MeV. A number of coaxial RF couplers [4,5 ] at frequency of 325 MHz are being fabricated to... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 1 |
42a08686-a1fe-4904-bbf8-f0aad0d4862a | source and amplify it with certain gain [7,8,9 ,10]. It is also known as a traveling wave resonator in which 35
high power builds up in the ring under certain operating condition s. In this resonant ring , the input power is 36
fed into the ring via a directional coupler [6] continuously leading to development of ... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 1 |
c63f48be-8ae5-4907-b5cb-20f496b100d2 | 2
NASA [11 ], ILC [ 12], e2V microwave technology center [13], IPR [14 ], IHEP [15], CERN [16], KEK [17] 41
etc. 42
The resonant ring developed at BARC is a WR 2300 half height waveguide based closed structure . The 43
design and simulation of the ring was carried out using CST studio suite [18]. The basic ... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 2 |
d40b9c90-80d2-4307-b7e6-b4d00f5ca3fd | 50
2.1 Layout and gain of the resonant ring: 51
52
Fig. 1 shows the basic layout of a resonant ring [7,8]. A r esonant ring consists of a primary line and a 53
secondary loop or ring. A part of the power generated from the RF source in the primary line is coupled to 54
the secondary loop/ring with the help of ... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 2 |
f3d23213-e07d-4725-b17d-e74c6cb140d2 | directional coupler , return loss , attenuation in the ring , transmission coefficient and electrical length of the 76
ring [7,8,9]. Once the components of the ring are identified, the insertion loss or attenuation of the ring can 77
be determined by calcu lating losses of all the components . Based on this at... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 2 |
5724c266-6983-49fd-9f17-c72495ede543 | 3
In Fig.1, a directional coupler couples power from input to the ring. It is represented as a four port network 80
with ports 1 -4. Port 1 is input port, port 2 is the through port, port 3 is the coupled port and port 4 is the 81
isolated port. The forward wave is represented as ‘a n’ and the reverse wave is re... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 3 |
afd2a85e-7b61-4428-8665-4d8e523407b4 | 87
where, C is the voltage coupling coefficient of the directional coupler [1 9,20] which couples power from 88
main line to the ring (C is the ratio of voltage at the coupled port to the voltage at the input port and it is not 89
in dB ), γ is the propagation constant ( γ =α+jβ), α is the attenuation constant, ... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 3 |
33840373-f082-472a-aaa2-08f43304c744 | |1−Te−jβl √(1−C2)|2 −−−−(4) 97
where, T is the transmission coefficient (it is not in dB) and accounts for the attenuation in the circuit 98
(attenuation = e−αl ). When the ring is in resonance, βl will be an integral number of 2π and the e−jβl phase 99
shift term will d... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 3 |
e593b2f9-4efa-4369-aa1e-2a2214e2e4b0 | a3=T2∗r∗b3+√(1−r2)∗T∗b4 −−−−(7) 105
b4=√(1−C2)∗a3 −−−−(8) 106
a4=T2∗r∗b4+√(1−r2)∗T∗b3 −−−−(9) 107
Rearranging equati... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 3 |
7b832714-582b-4368-8f3b-4dfc0b288959 | 4
It is evide nt from equations 4 and 10 that in order to maximize the gain, attenuation and reflections should 112
be kept to minimum. All the components of the ring structure are designed accordingly. Theoretically 113
calculated attenuation for aluminium WR 2300 waveguides used in our ring is 0.0 7 dB in one t... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 4 |
1eab253d-bfe1-4e58-994e-0cd02250e6f2 | (assuming there are no reflection s in the ring ). It is observed that for 0.4 dB attenuation ( with couplers ), the 119
gain is maximum at coupling of about 11 dB (corresponding to this power gain is 11.3 times) . For 13 dB 120
coupling , the gain obtained is very close to this value (10.45 times). Practically,... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 4 |
7f8ad2c2-4ca9-4208-a3d1-19d49514fe46 | considerable power gain . 130
131
132 05101520253035
8 10 11 12 13 14 15 16 18 20 22Power gain
Coupling (dB)attenuation 0.14 dB attenuation 0.4 dB
05101520253035
0.001 0.002 0.005 0.01 0.02 0.05Power gain
reflection coefficient (r)Fig. 2: Variation of ring g ain with coupling coefficient
Fig. 3: Variation of ri... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 4 |
691eb969-9cfb-4691-8c28-a015cf5586ec | 5
2.2 Power buildup in the ring: 133
134
The p ower buildup in the ring is illustrated in Fig. 4. Four stages are shown in this Figure. Fig. 4(a) shows 135
the input power , marked as red arrow , incident on the input port of directional coupler . Fig. 4(b) shows that 136
a part of this power is coupled to the ... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 5 |
d70d788b-01ad-4cba-9772-6c7c9ac10232 | as green arrows in Fig. 4(d). The b igger green arrow in the resonant ring indicates increase in power and 142
smaller green arrow at the load indicates reduction in power at the load. 143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 5 |
c3312086-ac38-4f71-8cdc-543d72671a89 | 6
Fig. 5 shows the transient behavior of the ring . In th is figure, Vin is the input voltage and Vring is the 173
voltage in the ring . The voltage inside the resonant ring increases with time due to phase addition of the 174
waves. This process continues till the steady state is reached. At steady state , th... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 6 |
c193a956-af36-4def-8833-b68b769ec1b2 | both the cases and the filling equations of the cavity will apply to the resonant ring structure. If the steady 184
state voltage in the ring is Vo, the equation representing the transient behavior of the ring is given as , 185
Vring =Vo (1−e−t
τ) ... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 6 |
e71bf4e8-431b-49ef-9fa1-8340254e0b40 | QL=fo
∆𝑓 −−−−(13) 193
194
where, Δf is the 3 dB bandwidth of the resonant ring , which can be determined from gain vs frequency 195
plot of the ring. 196
197
198
199 00.511.522.533.544.555.566.577.5
0 2 4 6 8 10 12 14 16 18 20 22 24Voltage (V)
time μsVin... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 6 |
aa3ae3ea-f3ee-4d77-84bb-b5b07fab4674 | 7
3. Design details of the ring setup 200
201
The design of the resonant ring depends on the required power gain , frequency of operation, power level etc . 202
It requires a number of components for its operation. The actual ring setup in our lab consists of a RF source 203
of 3 kW @325 MHz [21], primary ... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 7 |
2fdfb5fb-13b4-476f-ab15-c46d6962a5de | done without RF couplers . Later on , two RF couplers with a cavity will be added for testing. This cavity will 210
act as a transmission cavity between both the couplers. 211
212
213
214
215
216
217
218
219
220
221
222
223
2... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 7 |
99386656-09bd-4d25-83f9-227f006f4679 | 8
3.1 Directional coupler (13 dB): 239
240
This dual directional coupler is required to coupler RF power from primary line (waveguide section with 241
ports 1 and 2) to the secondary line (waveguide section with ports 3 and 4). The secondary line will be part 242
of the resonant ring. As discussed in section... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 8 |
a25b78c5-214c-461f-99bd-cd91a81d527a | practically achievable. The theory of this directional coupler is based on two hole couplers parted at a distance 248
of λg/4. The CST model of the coupler and its cut plane view are given in Fig. 7(a) and 7( b) respectively . 249
250
251
252
253
254
255
256
257
258
259
260
261
262
26... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 8 |
72e3dad9-c4e7-421b-8faf-41170dff9c3a | changing these values. Once coupling is finalized , the radius of holes is kept constant and the parameter ‘s’ 273
is varied to get maximum isolation and directivity. The effect of changing the paramet er ‘s’ to obtain best 274
isolation ( which is determined by S31) for a fixed frequency is shown in F ig. 8. Maxi... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 8 |
1b59f9e7-ee4d-4038-8afe-1ff73b511765 | 9
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
Fabricated directional coupler is shown in Fig . 9. Low level characterization of the directional coupler 295
was done on vector network analyser ( VNA ). The comparison of the designed, simulated and measured 296... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 9 |
d41cd4f1-0de3-4293-987e-9458cceb3267 | value ( dB) Measured value
(dB)
1 Return loss S11 >25 57 26.2
2 Insertion loss S21 < 0.5 0.19 0.3
3 Coupling (C) S31 13 13.5 13.1
4 Isolation (I) S41 > 38 68 38.1
5 Directivity (D =I -C)) S34 > 25 54.5 25.3 Table 1 : Parameters of 13 dB directional coupler
Port 2
Port 1
Port 3... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 9 |
fc5ca89b-3708-4b96-a8b9-ce7f5895e38a | 10
The RF power coupled in the resonant ring increases to the desired level in short time. To monitor this power 305
a half height waveguide based loop type of directional coupler [22] was developed providing coupling of 50 306
dB and directivity better than 30 dB. This directional coupler is part of the seco... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 10 |
339113c6-6acc-4c72-9577-9b0bb898ca99 | 318
319
320
321
3.3. Waveguide tuners and H bends 322
323
For resonance at desired frequency, it is required that the total length of the ring should be integral multiple 324
of guided wavelength. In order to have frequency tuning, waveguide tuners [4] are used in the ring . The 325
tuners are cylindr... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 10 |
9d73707e-f14c-469f-b118-697fdb691cfa | S.n
o Parameter S-parameter Designed value
(dB) CST simulation
value ( dB) Measured value
(dB)
1 Return loss S11 >25 53 28.2
2 Insertion loss S21 < 0.05 0.0005 0.02
3 Coupling (C) S31 50 51.5 50.5
4 Isolation (I) S41 > 75 86 80.6
5 Directivity (D =I -C)) S34 > 25 34.5 30.5
Table 2: Par... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 10 |
33628302-6590-416b-a08a-26274dd0d680 | 11
The secondary line of resonant ring structure needs to be in closed . This is required so that the wave can 331
travel back to the directional couple r and gets added in phase with the incoming wave for amplification. To 332
get the closed loop s tructure four waveguide H bends (90 degree) have been fabricat... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 11 |
81301586-7ca3-48b0-a3ec-e470a3941973 | These are matched individually to get very low reflection in the ring . 345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
Fig. 12: CST model of resonant ring
Waveguide bend
Loop type
directional coupler
Primary line directional
coupler
W... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 11 |
53979185-ae3b-46c9-ad00-3dc39e127c51 | 12
4.1 Gain and travelling wave in the ring 365
366
The tuner lengths in the resonant ring were varied to get the resonance at 325 MHz . The S 31 parameter , with 367
port 1 at input of 13 dB directional coupler and port 3 at the coupled port of loop type directional coupler in 368
the ring, gives the info... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 12 |
d64e278c-5fcc-42a6-9450-705e689fede6 | round is about 0.02 dB. As ideal components are taken for simulation, these loses are low as compared to the 377
estimated value obtained in section 2.1. The theoretical power gain obtained from equation 3 (for coupling 378
value of 13 dB and attenuation of 0.02 dB) is about 65.7 times, which is close to the gain ob... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 12 |
cd13d701-3eab-426a-afa6-d05923d897e3 | 12 and 13, the time constant obtained is 2.27μs. 389
During simulation , the e lectric field in the ring was also monitored. The 3 D electric field run show ed that 390
the field is continuously moving in one direction, indicating the travelling wave characteristic of the r esonant 391
ring. 392
393 -80-70-60-5... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 12 |
4f531ef4-0046-475f-92df-00b859a89ade | 13
RF Characterization and high power testing 394
395
Presently, RF power coupler development is going on at BARC. In order to study the resonant ring behavior, 396
it was closed with WR 2300 half height waveguide lines (without RF couplers ) and characterized using a 397
VNA . High power testing of the ring h... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 13 |
846b1bc6-a6f2-4931-b52c-cb7e3efb84d8 | ring was connected to the other port of VNA. The parameter S 31 gave information about the gain in the ring. 406
The tuners were optimized to get maximum gain at 325 MHz. S 31 obtained on VNA was -36 dB indicating a 407
gain of 14.5 dB (50.5 dB-36 dB) at 325 MHz. 408
The comparison between the simulated and mea... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 13 |
416add33-9269-475b-8e6f-a4025e6ad7f9 | 14
421
(a) (b) 422
423
424
From S31 vs frequency plot of Fig. 15 (b) (measured), the 3 dB bandwidth obtained is Δf=0.18 MHz. So, 425
the loaded quality factor from equation 13 is: 426
QL=fo
∆f=325
0.18 427
QL=1805 428
So... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 14 |
61cfe0fd-1758-42c9-9e33-d11e5b95fc74 | used between the signal generator and the ring to observe the input signal on one of the channels of the 442
oscilloscope. T he output signal from the loop type directional coupler was observed on the other channel of 443
the oscilloscope . This is shown in Fig. 16. 444
445 -70-65-60-55-50-45-40-35-30-25
300
30... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 14 |
808bbada-1431-48d4-a439-cb270df437e8 | 15
446
447
448
In Fig. 16, Vring is the voltage in the ring and V in is the input voltage. At t=20 μs, the input was switched 449
off. The time constant is the time taken by the ring to reduce to 1/e of its stead y state voltag e. In this case it 450
is 1.9 μs. Comparison of the simulated and measured value... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 15 |
536eb156-f637-4675-b0b8-ec3419b18ab9 | amplifier against any reflections from the ring. Water cooling has been provided to the circulator load and 461
the RF load connected at port 2 of 13 dB directional coupler. Temperature sensors have been used at these 462
two loads to monitor the temperatures during full power operation. 463 0123456
01234567891... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 15 |
65e0025e-a20d-4664-a1d4-9fde5f4ec04f | 16
464
465
466
After full integration of all components, the input power was slowly increased and the output power was 467
observed from the secondary loop type directional coupler in the ring. After optimization, the final power of 468
30.5 kW was obtained in the ring with the input of 1.1 kW. 469
All the ... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 16 |
81593e3e-7300-446f-8f61-bfb076a8a64a | 481
482
483
484
485
486
487
488
S no parameter value
1 Input power 1.1 kW
2 Power in the ring 30.5 kW
3 Resonant f requency of the
ring 325.12 MHz
4 Gain 14.4 dB
5 Bandwidth 200 kHz Fig. 17: Resonant ring setup for high power testing
Circulator
Coaxial
transmission line
Pr... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 16 |
4ebfb30e-bb2d-4632-aa96-c0431fda3f81 | 17
489
490
491
492
6. Conclusion 493
494
A travelling wave resonant ring has been set up at BARC for testing high power RF couplers. Design 495
simulations of the individual RF components and the entire ring was carried out using CST Microwave 496
Studio. After fabrication , RF components were i... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 17 |
7c300086-b795-4bf8-beb6-d5c047758f9c | with RF power couplers in future. It is also planned to raise the ring power by increasing the input power for 502
testing other waveguide components (like waveguide windows, ridge waveguide couplers etc.). 503
504
7.Acknowledgement 505
506
The authors would like to acknowledge the support for ring assembly... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 17 |
144953dd-dd8e-4dcb-844b-4df4bef64d39 | 18
[2] Abhishek Pathak, Shweta Roy, SVLS Rao, and Srinivas Krishnagopal, “Design study for medium 515
energy high intensity proton accelerator”, Phys. Rev. Accel. Beams 23, 090101< 516
https://journals.aps.org/prab/abstract/10.1103/PhysRevAccelBeams.23.090101 >. 517
[3] U. D. Malshe, “Low Energy High Intensity Pr... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 18 |
8a5b763c-8399-45e3-bbb2-db1ac9c700ca | [7] H. Buttig et.al. , “Study of the ELBE RF -couplers with a new 1.3 GHz RF -coupler test bench driven 525
by a resonant ring”, Nuclear Instruments and Methods A 612 (2010) 427 -437, 526
<https://doi.org/10.1016/j.nima.2009.10. 148>. 527
[8] V. Veshcherevich, Resonant Ring for high power test of RF Couplers”, htt... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 18 |
27d1a58a-35a1-4a63-abbd-16108474fe3c | March 1988. 535
[12] B.T. DU et.al. , “L-band Resonant Ring for Testing RF Windows for ILC ”, http://www - 536
linac.kek.jp/linac -paper/2 018/linac18 -du-resonantring.pdf . 537
[13] Keith Newsome et. al., “Resonant ring structures for testing high power low loss components ”, 538
https://www.armms.org/media/up... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 18 |
f7b70f6a-294e-40ff-9a5b-bc7ca8115557 | [16] U. Iriso,1 F. Caspers,1 J -M. Laurent,1 and A. Mostacci2, “Traveling wave resonant ring for electron 545
cloud studies”, DOI: 10.1103/PhysRevSTAB.7.073501. 546
[17] B.T. DU et.al., “High power operation of an L-band resonant ring” , Proceedings of the 16th Annual 547
Meeting of Particle Accelerator Society o... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 18 |
d93c3816-2f56-4f37-8674-4f850a35d77d | 19
[21] Patel Niranjan et. al., “Design and development of tetrode based 325 MHz, 3 KW radio frequency 554
(RF) system (pulsed and CW) for ring resonator”, Proceedings of the eighth DAE -BRNS Indian 555
particle accelerator conference -2018 , p. 996 -998. 556
[22] R.F. Schwarf et . al., “Criteria for the design of... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 19 |
fa122ff0-7fc0-4dc4-9ad3-30a50448c7f9 | Declaration of interests
☒ The authors declare that they have no known competing financial interests or personal relationships
that could have appeared to influence the work reported in this paper.
☐ The authors declare the following financial interests/personal relationships which may be considered
as pote... | d:\Zotero\sync\storage\ZQZVYX67\Sharma 等 - 2024 - Design and development of Resonant ring test setup at 325 MHz for high power testing of RF couplers.pdf | 20 |
0f4ca082-ca5d-4759-be54-59d90c10e884 | Journal of
Instrumentation
PAPER
Development and tests of the 499.8 MHz srf
cryomodules for HEPS
To cite this article: Hongjuan Zheng et al 2024 JINST 19 P10031
View the article online for updates and enhancements. You may also like
The high level applications for the HEPS
Linac
Y.-L. Zhao, H.-F. Ji, X.-H.... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 0 |
51e1d298-3a3c-47bd-8afc-fd59084e2b26 | 2024 JINST 19 P10031
P/u.sc/b.sc/l.sc/i.sc/s.sc/h.sc/e.sc/d.sc /b.sc/y.sc IOP P/u.sc/b.sc/l.sc/i.sc/s.sc/h.sc/i.sc/n.sc/g.sc /f.sc/o.sc/r.sc S/i.sc/s.sc/s.sc/a.sc M/e.sc/d.sc/i.sc/a.sc/l.sc/a.sc/b.scReceived: September 29, 2024
Accepted: October 9, 2024
Published: October 29, 2024
Development and tests of the 499.8 MHz... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 1 |
0c4325b6-e6b9-423a-a3f7-36105c14d019 | 19B Yuquan Road, Beijing 100049, China
𝑐School of Nuclear Sciences and Technology, University of Chinese Academy of Sciences,
19B Yuquan Road, Beijing 100049, China
E-mail: zhangpei@ihep.ac.cn, maqiang@ihep.ac.cn
Abstract: A 499.8MHz single-cell superconducting cavity has been proposed as the active third-
harmonic cavi... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 1 |
ee85b2f2-a8d9-4be3-a1ed-97a9d7a7ec5f | clean-assembly procedure was developed, resulting in excellent rf performance maintained from
verticalteststohorizontaltestsatcryogenictemperatures. Theunloadedqualityfactorsofallthree
modules exceeded 2.45×109at 1.75MV, significantly surpassing the design goal. No field emissions
wereobservedthroughoutthetests. Thesea... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 1 |
41e9bc06-2a46-49f3-a8ce-165518d14056 | presents the design, fabrication, assembly, cryogenic tests, and transportation of the mechanically
improved 499.8MHz single-cell srf cryomodule.
Keywords: Acceleration cavities and superconducting magnets (high-temperature superconductor,
radiation hardened magnets, normal-conducting, permanent magnet devices, wiggler... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 1 |
6fe18416-a5eb-428f-a934-5e2b0497c656 | 2024 JINST 19 P10031Contents
1 Introduction 1
2 Cavity system 3
2.1 RF design 3
2.2 Mechanical design 4
2.3 Cavity fabrication, surface preparation and rf testing 5
2.4 Higher order modes 8
2.5 Synchrotron light irradiation 8
3 Cryomodule assembly and integration 9
4 Horizontal tests 10
4.1 Warm conditioning 10
4.2 Coo... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 2 |
0273e5c8-0a1f-4e88-b8b7-6a8af7ec8481 | of34pm·rad,promisingaradiationbrightnessof 5×1022photons/s/mm2/mrad2/(0.1%bandwidth)
inthetypicalhardX-rayregime. Thestoragering,withacircumferenceof1360.4m,operatesata
beamcurrentof200mA.Adouble-frequencyradiofrequency(rf)systemwasemployedtoenablea
novelbeaminjectionschemeknownason-axisaccumulationinjection,initiallyd... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 2 |
25df8372-7bf4-437d-8dee-65f9a7995efd | shown in figure 1. It is important to note that the third-harmonic rf is active rather than passive.
HEPSrequiresheavydampingofhigherordermodes(HOMs),leadingtotheadoptionofasingle-
cell cavity design with beam-pipe absorbers [ 6]. The established KEKB-type single-cell elliptical
geometrywasselected[ 7]. The499.8MHzcavi... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 2 |
31f70818-95e9-4e03-b91e-bef7132460ae | 2024 JINST 19 P10031
Figure 1. Layout of the HEPS rf system.
reinforcement schemewas developed, incorporatingincreased cavitywall thickness andtwo on-cell
stiffeningringstoensurecompliancewithpressurevesselcodesunderdifferentworkingconditions.
As a synergy between HEPS and BEPCII Upgrade (BII-U) [ 10], the cryomodule d... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 3 |
d3807c47-325a-4b13-8047-92c6c81db1b2 | a maximum of 3.5MV rf voltage and 400kW of beam power, with an rf voltage of 0.91MV required
for bunch lengthening, absorbing 104.3kW of power from the beam. The substantial margin in the rf
parameters is reserved for future implementation of the on-axis accumulation injection scheme.
Figure 2. Cryomodules of HEPS and ... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 3 |
7d7c30b2-b883-4084-ba4d-f0fabbea1293 | 2024 JINST 19 P10031Three 499.8MHz cryomodules were developed, with two designated for HEPS and one for
BEPCII-U, and underwent high-power testing at the horizontal test stand at the Platform of Advanced
Photon Source Technology R&D (PAPS). All three modules demonstrated excellent performance.
Subsequently,onemodulewas... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 4 |
e1343655-7e8e-4501-b93b-31ffc49fa900 | process. Thevacuumlevelandcryogenicperformancewerenicelymaintainedfollowingtherelocation.
The module has been accelerating the electron beam at HEPS since August 2024.
Thispaperdetailsthedesign,integration,andperformancetestingofthe499.8MHzcryomodules.
Additionally, the transportation oftwo modules, over short andlong ... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 4 |
7adff110-2c4c-4a4b-a213-f877ae69839a | onbothendswerechosentoallowallHOMstoexitthecellandsubsequentlybeattenuatedbythe
beam-line absorbers at room temperature [ 12]. The main parameters of the cavity are listed in table 1.
Figure 3. (a) Cavity rf geometry, (b) electric and (c) magnetic field distributions of the accelerating mode
(normalized to a stored ene... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 4 |
e507819a-e77b-4dbd-89e3-5c1756c27e1d | 2024 JINST 19 P10031Table 1.Main parameters of the 499.8MHz cavity. “LBP” stands for large beam pipe, “SBP” stands for small
beam pipe, “VT” stands for vertical test.
Parameter Value Unit
Resonant frequency 499.8 MHz
Cavity length (flange to flange) 961 mm
Accelerating gap 266.5 mm
Iris diameter 220 mm
LBP diameter 300... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 5 |
e7d8db13-5938-42c2-b17f-45d57f527822 | Lorentz coefficient Hz/(MV/m)2−5.4
Buckling critical factor - 30.2
2.2 Mechanical design
TheoriginalKEKBcavitywasmadeofpureniobiumsheetsof2.5mm,witharesidualresistanceratio
(RRR) of 200 [ 7]. The cavity was fabricated by using the spinning method, and the wall thickness
variedfrom1.8to2.7mm. However,thislimitedtheopera... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 5 |
e8e9512a-a363-4801-8516-bc467ecd0bba | wasspecifiedas2baratroomtemperature(293K).Apairofstiffeningringswereaddedtothecell
to prevent collapse due to buckling under various working loads.
The peak stress reads 76MPa located on the iris of the dressed cavity, which marginally exceeds
thepermissiblevalueof 70.5MPa fordiscontinuitiesunderMAWPatroomtemperature. ... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 5 |
cbe10b8b-66ea-428f-b3e6-fe1dca4ae176 | 2024 JINST 19 P10031
Figure 4. (a) Stress and (b) deformation of the dressed cavity under 2bar external pressure.
Thecavity’stuningsensitivityis346.1kHz/mm,withastiffnessof12.5kN/mm. Thetuningrange,
determined by the allowed peak stress, is ±219kHz at room temperature. The pressure sensitivity
is−4.2Hz/mbar with both b... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 6 |
a26608d5-09e2-4982-b64f-6a205b7714bb | Mechanical resonances induced by external vibrations in the cavities of a cryomodule can
impacttheresonantfrequency,leadingtoinstabilities. Amodalanalysiswasperformedtoexamine
the cavity’s natural vibration, revealing that longitudinal modes pose the greatest risk of causing
frequency detuning. The frequency of the low... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 6 |
62f5e065-46ef-4bc6-af32-34ba88a4ebde | 2024 JINST 19 P10031largebeamtubeandthetransitionpipe. Theinnersurfacesofthecavitieswerecarefullyinspectedand
ground,ifnecessary,beforeeachweldingsteptopreventdefects. Followingfabrication,astandard
post-processingprocedureforsuperconductingcavitieswasfollowed[ 14,15]. Thecavitieswerefirstly
degreased in an ultrasonic ... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 7 |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.