id stringlengths 36 36 | text stringlengths 1 1k | source stringlengths 42 191 | page int64 0 1.03k |
|---|---|---|---|
1875db80-5c99-4e10-a926-d265ae01f0e9 | (ISO 4) cleanroom. After assembly, the cavities were slowly pumped and leak-checked. Then baking
at 120◦C for 48 hours was conducted followed by a final leak check preceding the vertical tests.
Figure 5. (a) Parts and components of the cavity. (b)-(g) Fabrication photos of the main components.
Toensuretheoperationofthe... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 7 |
b1597974-8f52-409a-b6ad-ed396c0002e6 | 2024 JINST 19 P10031The cavity fabrication process can be broken down into four primary stages as shown in figure 5:
deep-drawing cups, welding the SBP with the cup, welding the SBP groups with the cup, and
finally welding the components to form a complete cavity. Following the second stage, frequency
measurements, and... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 8 |
10e71b35-fd0c-4266-a906-1e2e75f29a74 | regions. Following the BCP of the first cavity, the measured frequency variation coefficient was found
to be−0.0013MHz/μm and updated in the calculation accordingly.
Inordertoestablishthetargetfrequencyunderstandardconditions,frequencycorrectionsresulting
from cooling down, preloading, and atmospheric factors were anal... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 8 |
5e86eeb0-5e86-4ca8-bf61-7e394799c87e | Theunloadedqualityfactor 𝑄0ofthebarecavitieswasmeasuredasafunctionoftheaccelerating
voltage𝑉𝑐,andthetestingresultsareshowninfigure13. Themaximumvoltageattainedwas4.35MV,
corresponding to a 𝑄0value of 1.3×109. All cavities achieved voltages exceeding 4MV with
associated𝑄0valuesgreaterthan 1.0×109. Nofieldemissionso... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 8 |
02986432-04d0-44de-85e7-d022b256ebdb | 2024 JINST 19 P100312.4 Higher order modes
Inastoragering,beaminstabilitiesinboththelongitudinalandtransversedirections,causedbythe
rfsystem,primarilyoriginatefromthecavitiesthemselves. TheHOMsexcitedbytheintensebeam
bunchesmustbeeffectivelydampedtopreventadditionalcryogeniclossandcoupled-bunchinstabilities
(CBI)[16]. ... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 9 |
24f34759-dd53-4711-ba6d-812eb636ab3b | An active rf cavity with a resonant frequency near a harmonic of the fundamental rf may enhance
Landaudampingofsynchrotronoscillations,increasingthebunchlength,therebysuppressingCBIand
extending the Touschek lifetime. Upon the installation of third harmonic cavities, the bunches in the
storageringwillbeelongated,thusal... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 9 |
b2ca6dff-46ab-4a0e-9e80-9b384a7f7f33 | HOMs effectively, a small ferrite absorber with a diameter of 220mm and a large absorber of 300mm
willbeinstalledoneachsideofthecavitybeampipes,asshowninfigure7. Theapertureatthetaperexits
is63mm. Thedampedresultsforalllongitudinalandtransversemodes,comparedwiththeimpedance
thresholds, are shown in figure 8. The simula... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 9 |
b013c0f5-de35-4df4-89c4-97955e17da8e | high-chargeoperationmode,thebeamiscomposedof63bunches,eachcarryingachargeof14.41nC,
and an average power loss of 5.7kW to HOMs.
2.5 Synchrotron light irradiation
Theilluminationofsynchrotronlightonthecavitystringneedstobeassessedtoavoiddirectirradiation
onsuperconductingcavitysurfacesandsensitive beamlinecomponentslike... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 9 |
e518fe06-c193-42cf-bb55-bf48caf91da0 | 2024 JINST 19 P10031
Figure 8. (a)Cavityimpedancecomparedwiththelongitudinalimpedancethresholdwithandwithoutharmonic
cavities. (b) Cavity impedance compared with the transverse impedance threshold. 𝑍𝑥,𝑦_𝑡ℎstands for the
transverse impedance threshold in the horizontal and vertical directions, respectively.
componen... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 10 |
cfeb36e8-1c78-4859-b536-4aaee4925ccf | power is 186W on a surface of 89.2mm2.
Figure 9. Synchrotron light irradiation on the 500MHz module at ID35.
3 Cryomodule assembly and integration
Thecryomoduleswereassembledandintegratedineightsteps. AftertheHPRofthecavityandthe
two thermal-break tubes, these three components were firstly assembled in a Class 10 clean... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 10 |
10e8ffa8-e67c-4bb5-a9cc-e83e7c8c81d6 | 2024 JINST 19 P10031the tank and also supported on both blind flanges from the bottom as shown in figure 10(b). The
modulewasthentransferredtoanothercleanroom,wheretheouterconductorofthepowercouplerwas
mounted on the cavity string. To ensure cleanliness during this step, an additional portable cleanroom
was installed o... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 11 |
39bbd126-44ce-4e65-b096-a9c3002f159a | thoroughly cleaned beforehand. The assembly procedures are detailed in figure 10(e)-(f). Baking
at120◦Cofbothtaperassemblieswasconductedforaminimumof48hours. Theassemblyofthe
tapers,vacuumvessel,andinnerconductorofthepowercouplerwasalsocarriedoutinthecleanroom,
as shown in figure 10(g). Following a final leak check of ... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 11 |
92f06565-c14d-4416-8a1a-40c6caf13c6d | temperature,thepowercouplerwashigh-powerconditionedwiththecavitydetunedatroomtemperature.
Themaximumoutputpoweroftheamplifierwaslimitedto160kW.Warmconditioningwascarried
out using the pulse-cw-alternate method and DC biasing [ 8,18]. The cw and pulse powers during
conditioning reached 160kW, respectively, while the bia... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 11 |
24b8562b-b985-43dc-82be-be8ef7d0710e | requirementsalsoappliedtothewarm-upprocess. Followingthecooldown,thefrequencyandthe
loadedqualityfactorofthecavityweremeasuredagain. Thefrequencyshiftsofthethreecryomodules
resulting from the cooldown process are shown in figure 6. The displacements of the beam pipes
during both cooldown and warm-up processes were meas... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 11 |
5fca8575-34ef-42e0-9f04-d6b81b44f256 | 2024 JINST 19 P10031
Figure 10. (a) Step 1: assembly of cavity and thermal break tubes. (b) Step 2: assembly of cavity string in
theliquidheliumtank. (c)Step3: installationoftheoutconductorofthepowercoupleronthecavitystring.
(d)Step4: installationofthecanforLN2shield,flangesforthevacuumvessel,andheliumvessel. (e)Step5:... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 12 |
e6298c0e-62a1-4d04-9887-611094cd7518 | module has the largest static heat load of 31W due to unsatisfactory wrapping of the multilayer
insulation,whichhasbeensignificantlyimprovedintheHEPSmodules. Asaresult,thestaticheat
load was reduced by one-third to 20–23W.
– 11 – | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 12 |
c19be5b1-e2a2-49ec-b208-57be824c977a | 2024 JINST 19 P10031
Figure 11. DisplacementsoftheLBPsandSBPsforallthreemodulesafterthecooldownandwarm-upprocess.
“Long”standsforlongitudinaland“Vert”standsforvertical. Thenegativedisplacementindicatesthatthecavity
stringshrinksinthelongitudinaldirectionandmovesverticallytowardthebottomofthecryomoduleduring
thecool-dow... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 13 |
e0664248-310d-43ae-ac03-48bbde22ec49 | 2024 JINST 19 P10031
Figure 13. Quality factor and radiation level of the cavities during horizontal tests, compared with vertical test
results. “VT” stands for vertical test, and “HT” stands for horizontal test.
where𝑄pu
extis the external quality factor of the cavity pickup and was measured before and after
cooldown... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 14 |
977c4dd4-9ff2-4d24-9175-638002fd4dcb | Figure13presents theunloadedqualityfactor 𝑄0andtheradiation levelofallthreemodules at
various accelerating voltage 𝑉𝑐measured during horizontal tests. These results are compared with
the vertical test results of the corresponding bare cavities. The results indicate that 𝑄0values of
all three modules at 1.75MV were ... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 14 |
de160cba-8eab-41da-bb13-82634da7d497 | intheavailablepoweroftheamplifier,themaximumacceleratingvoltagewasrestrictedto2.0MV,
withacorresponding 𝑄0valueof 2.4×109. Minimaldegradationwasobservedincavityperformance
from the vertical tests to the horizontal tests, and the radiation level remained low. The quality factors
ofthesemodulesrepresentthehighestvaluesa... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 14 |
f4197e83-1760-46bd-8968-d964326d2e42 | 2024 JINST 19 P10031Theresonantfrequenciesofallthreecavitiesweresuccessfullyadjustedto499.8MHzat4.2K
using tuners. The tuning sensitivity and tuning stiffness for these modules were measured, and the
results are summarized in table 2. Furthermore, the frequency tuning with respect to the piezo
voltage was also measured... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 15 |
6fa99801-8c70-48f2-bf52-570163eaf182 | Tuning accuracy Hz/V 18.9 16.7 7.5 -
Asuccessfulprocedureforfabrication,post-processing,cleanassembly,andintegrationforthe
499.8MHz cryomodule has been established.
5 Cryomodule transportation
Once the modules have completed their horizontal tests at the PAPS site, they will be transported
to the storage ring tunnel of... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 15 |
24117c79-0076-4382-b5fc-29634d1a385e | DESY, and LCLS-II cryomodules [ 28–30], modal and stress analysis under different accelerations for
sensitive components have been carried out. Road tests were performed with dummy loads of the
same weight as the cryomodule, with accelerometers installed to record shock events on strategic
locations during the road tes... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 15 |
f48c69a8-ff92-4246-aa86-422d326ce02c | and insulating vacuums must remain uncompromised, the physical deformation of components should
be minimized, and the cryomodule’s performance should not be degraded.
5.1 Modal frequencies and stress analysis
The natural frequencies of the FPC’s inner conductor under the boundary condition shown in
figure14(a)havebeena... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 15 |
d52da21d-327d-4b5d-8398-b01b1f7b9f18 | 2024 JINST 19 P10031
Figure 14. (a) Boundary condition: bottom flange of the FPC’s inner conductor is fixed. (b) The modal
frequencies of FPC inner conductor. (c) Mode 1. (d) Mode 3.
The subsequent analysis focused on the maximum stress and distribution on the ceramic window,
the thin-walled copper pipe at the welding ... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 16 |
24f8feba-2069-4e74-8159-a7e22d2a39dc | the outer surface. The bottom flange of the FPC window was fixed. A load of 1.1g was applied in the
𝑥and𝑦direction respectively, and 5.8g in the 𝑧direction (gravity). The simulation results are shown
infigure15. Thepeakstressisrecordedas23.5MPaattheweldingpointbetweentheceramicandthe
innerconductor. Sincetheflexural... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 16 |
c0776cc5-273a-41ab-9d50-f0ed856ee2cc | 0.7mm at the end of the antenna, and the maximum deformation of the welding between the ceramic
window and the outer conductor is 0.003mm, as shown in figure 16. The coupling changed by the
deformation of the inner conductor is about 5%, which is acceptable.
– 15 – | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 16 |
5088938c-21bd-455d-9cd2-4188781553d2 | 2024 JINST 19 P10031
Figure 15. Stress distribution on (a) the welding between the ceramic and the inner conductor, (b) the ceramic
window,(c)thethin-walledcopperpipe,and(d)theweldingbetweentheceramicandtheinnerconductor,when
1.1g acceleration added in 𝑥,𝑦direction and 5.8g in 𝑧direction.
Figure 16. Deformationon(a)... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 17 |
067e3737-6678-4036-8f08-34cb96ee77b1 | recorded in the axial, transverse, and vertical directions, respectively, on the blocks. No shock events
exceeding 0.6g were observed during thetests, indicatingthe readiness of the module transportation.
– 16 – | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 17 |
236be1ef-e49b-4cb1-930e-918e054ae33f | 2024 JINST 19 P10031The cryomodule was loaded onto a flatbed trailer without an air-ride suspension system. Six
accelerometerswerestrategicallymountedonvariouscomponentsofthemodule,asshowninfigure17.
The event recording threshold was set to 0.2g for all three directions, with a sampling rate of 1024Hz.
Peak acceleratio... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 18 |
44780b53-0542-4168-acd6-e580b7c565f4 | during module loading and unloading. The spectra of one such event are shown in figure 19. A
peak around 36Hz is evident for the two horizontal directions, consistent with simulation predictions
(figure 14), indicating a pendulum motion of the inner conductor. Prolonged movement under this
mode may pose a risk of damag... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 18 |
30a11825-8582-4e5a-939e-9ea20e6339d0 | compromised. The module was subsequently connected to the cryogenic system and cooled down to
4.2K.Evaluationofthecavityperformancerevealedaqualityfactorof 2.8×109at1.80MV,showing
no degradation compared to the value obtained from the horizontal test at PAPS before transportation
(2.7×109at 1.81MV). No increase in fiel... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 18 |
bfd99511-fa62-4760-85dc-80c973a9fab5 | 2024 JINST 19 P10031
Figure 18. (a) Horizontal and (b) vertical acceleration recorded for the transportation of HEPS cryomodule.
6 Conclusions
Amechanicallyimproved499.8MHzsuperconductingsingle-cellcavitydesignwasadoptedforthe
HEPS storage ring and BEPCII upgrade. To enhance cavity performance and prevent contamina-
ti... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 19 |
800a3fe9-0cb5-4616-b68c-a3ddafd8abd0 | 2024 JINST 19 P10031
Figure 19. Shock event with the highest horizontal acceleration recorded on FPC window (S1) during module
loading.
and their performance was comparable to that of the bare cavities during vertical tests. The static
heatloadofthecryomodulecanbereducedtoaslowas20Wafterimprovedmultilayerinsulation
wra... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 20 |
6e1378e9-561c-4555-a354-352d117e7037 | ondelicatecomponents. Thevacuumintegrityandperformanceofthemodulewerewellpreserved.
ThecryomodulehasbeenacceleratingelectronbeamssinceAugust2024fortheHEPScommissioning.
Acknowledgments
We would like to acknowledge Dr. Lin Guo for her help during cavity vertical tests. We would like to
thankourcolleaguesintheRFgroup,Cry... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 20 |
87655b2a-a247-4379-a8a0-2e3ab8df1f0a | 2024 JINST 19 P10031References
[1] Y. Jiao et al., The HEPS project ,J. Synchrotron Radiat. 25(2018) 1611.
[2] H. Xu et al., Equilibrium electron beam parameters of the High Energy Photon Source ,Radiat. Detect.
Technol. Methods 7(2023) 279.
[3] P. Zhang et al., Radio-frequency system of the high energy photon source ,... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 21 |
fd96ddc3-d346-493b-a8b8-a4899c6232af | [DOI:10.18429/JACoW-IPAC2018-THPMF052 ].
[6] N. Wang et al., Studies on Collective Instabilities in HEPS , in the proceedings of the 8thInternational
Particle Accelerator Conference , Copenhagen, Denmark, May 14–19 (2017)
[DOI:10.18429/JACoW-IPAC2017-THPAB030 ].
[7] K. Akai et al., RF systems for the KEK B factory ,Nuc... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 21 |
b2ccdf2a-45d3-4280-99f5-1ad076f65a0e | [DOI:10.18429/JACoW-IPAC2021-THPAB002 ].
[11] Z.Li, G.Wang, W.Pan, Y. Sun,S. Li,Q. Maet al., Fabrication and test of the 500 MHz SC modules for
the BEPCII , in proceedings of the 13thInternational Conference on RF Superconductivity , Beijing, China,
October 14–19 (2007), pp. 503–505, http://epaper.kek.jp/srf2007/PAPERS/... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 21 |
154645c5-069d-4fbe-99d3-6a8fb20146d6 | [14] H. Zheng et al., Development and vertical tests of 650 MHz 2-cell superconducting cavities with higher
order mode couplers ,Nucl. Instrum. Meth. A 995(2021) 165093.
[15] L. Guo et al., Development of a 166.6 MHz 𝛽=1higher-order-mode-damped superconducting cavity ,
Rev. Sci. Instrum. 95(2024) 074702.
[16] H. Padam... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 21 |
5862098e-43d2-4532-9259-e53cb5b19869 | 2024 JINST 19 P10031[19]B. Lin, L. Shao-Peng and L. Ya-Ping, Measurements of Static Heat Loss and Unloaded 𝑄0on the BEPCII
SRF Cavities ,Chin. Phys. C 32(2008) 166.
[20] B. Lin, L. Shao-Peng and Y. Huan, Static thermal load analysis of Beijing Electron-Positron Collider
Upgrade superconducting cavity cryostat ,Cryogeni... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 22 |
637a36de-5604-4b54-8ebb-6a23d30a5473 | the proceedings of the 6thInternational Particle Accelerator Conference , Richmond, U.S.A., May 03–08
(2015) [ DOI:10.18429/JACoW-IPAC2015-WEPWI052 ].
[23] M.R.F. Jensen et al., Status of the Diamond storage ring radio frequency system ,Conf. Proc. C 060626
(2006) 445.
[24] Z.M. Dai et al., Status of the SSRF Storage R... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 22 |
3517e32f-61b4-4af0-abed-d11e1f3920b2 | 23–27 (2013), pp. 263–265,
[27]M.H. Chang et al., Status and upgrades of radio frequency system at Taiwan Photon Source ,J. Phys. Conf.
Ser.2687(2024) 082008.
[28] C. Curtis et al., Shipping and Alignment for the SNS Cryomodule ,Conf. Proc. C 0106181 (2001) 1488.
[29] G. Sikler, Transportation of Cryomodules , Tech. Re... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 22 |
f853128c-30c6-4e3a-bc09-15d37cd4a2ac | [32] Mitsubishi Electric, BEPCII Superconducting Cavity , Tech. Rep., Vol. 2, (2005).
[33] From Morgan Technical Ceramics, Wesgo Ceramics.
[34] https://www.matweb.com/.
[35] M. Merio, Material Properties for Engineering Analyses of SRF Cavities , Fermilab Specification:
5500.000-ES-371110, Batavia, IL, U.S.A. (2011).
–... | d:\Zotero\sync\storage\ZR4XW3HG\Zheng 等 - 2024 - Development and tests of the 499.8 MHz srf cryomodules for HEPS.pdf | 22 |
e0cf339e-6121-43d7-8580-e912a8e207ff | Journal Pre-proof
Calibration of superconducting radio-frequency cavity forward and
reflected channels based on stored energy dynamics
Andrea Bellandi, Julien Branlard, Marco Diomede, Max Herrmann,
Sven Pfeiffer, Christian Schmidt
PII: S0168-9002(24)00751-4
DOI: https://doi.org/10.1016/j.nima.2024.169825
Reference: NIM... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 0 |
8aa66c94-9d22-4677-a530-f1bea5d83a03 | This is a PDF file of an article that has undergone enhancements after acceptance, such as the
addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive
version of record. This version will undergo additional copyediting, typesetting and review before it
is published in its... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 0 |
5b154fa6-fdfb-4d7f-a327-03572e479c92 | Journal Pre-proofJournal Pre-proof
Calibration of superconducting radio-frequency cavity 2
forward and reflected channels based on stored energy 3
dynamics 4
Andrea Bellandia,∗, Julien Branlarda, Marco Diomedea, Max Herrmanna, 5
Sven Pfeiffera, Christian Schmidta6
aDeutsches Elektronen-Synchrotron DESY, Notkestraße. 85... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 1 |
1440aa79-182c-40d5-a5c1-29318445c8ff | RF control systems. Past work proposed a compensation method employing
least-squares optimization. This method requires the directivity of the directional
couplers to be much higher than one. Additionally, the algorithm requires
a tuning parameter to optimize the calculated calibration. However, for
some accelerating s... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 1 |
ebbfaca6-41a4-4d3d-b7bb-695cf8bf5fe2 | factors of 4 .6·106and 2 .8·107.
Keywords: LLRF, Signal calibration, Superconducting RF, Accelerating 8
cavities 9
∗Corresponding author
Email address: andrea.bellandi@desy.de (Andrea Bellandi)
Preprint submitted to Elsevier August 13, 2024 | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 1 |
a058184b-ad23-4714-9beb-4fe1df3b5d20 | Journal Pre-proofJournal Pre-proof
1. INTRODUCTION 10
The task of continuously estimating the state of Superconducting 11
Radio-Frequency (SRF) cavities is essential for the efficient operation of linear 12
particle accelerators. The cavity unloaded quality factor or Q0is related to 13
the losses dissipated in the cryo... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 2 |
971b3419-654e-46ba-bc2b-81d2a20a42c5 | Assuming Qextto be constant during operations, the variations in cryogenic 21
heat losses can be estimated by measuring ω1/2. It is also assumed Q0≫Qext 22
during nominal operation. Therefore a cavity quench, that reduces Q0by 23
several orders of magnitude, makes ω1/2deviating from ≈ω0
2Qext. A protection 24
system ne... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 2 |
195fee71-fd27-461c-9acb-7ab4a28d3b9a | or pulsed machines with a duty factor of several ten percent, alternative 31
methods have to be used. 32
Another important parameter that needs to be estimated in real-time is 33
the cavity detuning ∆ ω. Such a parameter describes the difference between 34
the frequency of the high-power driving signal and the cavity r... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 2 |
aaf99105-3b5a-490d-b4fc-ecc3319690a7 | Journal Pre-proofJournal Pre-proof
Figure 1: S.P.A. FERRITE, WDHC 3-3A bi-directional coupler for 1.3 GHz waveguides.
The declared directivity is 40 dB
where r/Qis the shunt impedance and VP∈Cis the accelerating voltage or 38
calibrated probe signal andIbthe beam current. The real and imaginary parts 39
ofVPrepresent r... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 3 |
93fda2f9-433c-47c1-8f50-a80fae6be6a9 | are used. However, imperfections in the RF measurement chain result in 47
errors in the estimated states. One of the most important systematic error 48
in the measurements arises from waveguide directional couplers (Fig. 1) used 49
to sample the forward ( VF) RF signal sent from the RF high-power amplifier 50
and refle... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 3 |
e2158126-7741-4192-9f57-67d9c30fcd16 | Journal Pre-proofJournal Pre-proof
LLRFRF cavity
AmplifierWaveguide
couplerFigure 2: Simplified RF cavity-based accelerating system. A waveguide connects the
high-power amplifiers to the cavity. On the waveguide, a bidirectional coupler is used to
sample the forward VFand reflected VRRF components.
case, the isolation o... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 4 |
ec8e6a24-b455-42f1-885f-5e8eb5d452e8 | whole chain, it would be possible to estimate the parameters of (4) and (5). 64
However, in practice, this procedure might be excessively time-consuming, 65
error-prone, and affected by drifts like the humidity and temperature dependence 66
of RF cables. 67
2. DISCUSSION ON THE CURRENT METHODS FOR SIGNAL 68
CALIBRATION... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 4 |
de71c06f-9fd4-462b-81d1-a117943d8e10 | Journal Pre-proofJournal Pre-proof
VP(n) =VF(n) +VR(n)∀n∈N, (6)
where Nis the set of the indices of the recorded data samples. Equation 75
(6) states that the sum of the forward and reflected waves at the end of the 76
transmission line is equal to the voltage on the termination load which, in this 77
case, is the SRF ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 5 |
c5149a09-670a-41bc-a2d9-c40d73ac2ef8 | hold. 85
2.1. Diagonal calibration 86
If the effect of the finite directivity is negligible for the intended application, 87
the non-diagonal terms b, cof (4) and (5) can be set to zero and only a, dare 88
used. It is then possible to find the diagonal terms of the over-determined 89
system of (6) using a least square ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 5 |
ea4dbb26-a7a1-4fa6-a7fe-41acdf8e172e | pulse in the SRF resonator. The data is then divided into two parts 97
N=Npulse∪Ndecay, (7)
with Npulsethe set of the indices when the amplifier that excites the cavity is 98
generating an RF signal and Ndecaythe set of indices when the same amplifier 99
is switched off and the cavity field follows an unforced decay. T... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 5 |
43c22666-b6e0-47b7-b8f7-f888209c9076 | Journal Pre-proofJournal Pre-proof
Equations (8) and (9) state that the forward signal VFis equal to zero during 102
the decay period and, as a consequence of (6), the reflected signal VRis equal 103
to the probe signal. The above constraints turn out to be too strict, since the 104
measurement noise results in (6) to ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 6 |
5932726f-abe1-47ec-b98a-397ccfd6ecd5 | practical application in other facilities: 112
1. The suggested procedure is to evaluate the calibration with kadd= 1. 113
If the computed calibration is not satisfactory, the calibration should 114
be repeated at different values of the parameter. Then, the result that 115
minimizes the standard variation of the estim... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 6 |
e79016d0-6ad7-4e35-9877-7e2fa7529d09 | much smaller than unity. This might not be true for every facility. 123
3. Systems that show a significant reflection of VRback to the cavity 124
are not expected to fulfill (10). This may happen, for example, if a 125
mismatched RF element is present in the waveguide system. 126
2.3. Calibration from A. Brandt 127
Ano... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 6 |
08ebf7a7-6536-46eb-b446-20446c8900b5 | Journal Pre-proofJournal Pre-proof
The parameters xandyare respectively the adiagandddiagcalibration 130
coefficients determined using the diagonal method. zis the solution of the 131
over-determined linear system 132
z=a
b=−Vm
R(n)
Vm
F(n)∀n∈Ndecay. (14)
With (11),(12) and (13) only aneeds to be found. To calculate th... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 7 |
99516258-b95f-4096-8ee1-28842f262882 | until the convergence of ˆ atoa. 139
One possible limitation of Brandt’s method is that it depends on the 140
value of z. Therefore the precision of measurement of Vm
F(n) during the 141
decay phase has an impact on the final calibration. Since the magnitude of 142
Vm
F(n) during the decay is proportional to b, the sig... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 7 |
b82f5b0a-bb30-44dc-b8b6-e4f90990a2a2 | dVP(n)
dt≃0∀n∈N. (16)
Using the condition in (16) it is possible to derive the optimization problem 150
a= arg min
ˆa∑
n∈N⏐⏐⏐VF(n; ˆa)
VP(n)−1
2⏐⏐⏐ (17)
Since in this paper only calibration algorithms that require a pulsed RF 151
structure are compared, no further discussion will be done on the method of 152
Qiu et al.... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 7 |
7075812b-4754-4c40-8898-8aca67d73478 | Journal Pre-proofJournal Pre-proof
3. DERIVATION OF THE ENERGY-BASED CALIBRATION METHOD 154
To overcome the limitations of the above methods, we present a new 155
calibration procedure that is based on the superconducting cavity system 156
dynamics. Unlike Brandt’s method, the whole set of calibration parameters 157
(a... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 8 |
2c1334f9-37fe-43f7-a62e-482d06318346 | ∀n∈N.
From (19), the optimization problem of (15) can be derived by expressing 164
it in terms of aand minimizing the difference of its right and left side. Instead, 165
the non-differentiated terms of VPare substituted with (6) 166
1
2ω1/2d|VP(n)|2
dt=|VF(n)|2− |VR(n)|2∀n∈N. (20)
Since (20) depends only on the square ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 8 |
f00697c6-2c69-439f-bf38-24f86992dae2 | equations. However, it is found that not using (20) results in an insufficiently 173
constrained magnitude of the cross-coupling term of the reflected signal 174
and, as a consequence, decreases the accuracy of the calculated calibration 175
parameters. Therefore it is possible to formulate an optimization problem to 1... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 8 |
1a56c0c3-27ee-4e5c-9a94-050c26c03241 | Journal Pre-proofJournal Pre-proof
(a, b, c, d ) = arg min
ˆa,ˆb,ˆc,ˆd(∑
n∈N(|fprobe(n; ˆa,ˆb,ˆc,ˆd)|2+
|fC(n; ˆa,ˆb,ˆc,ˆd)|2+|fD(n; ˆa,ˆb)|2))
. (21)
The terms fprobe, fC, fDrepresent the errors given by subtracting the left and 178
right sides of (6), (20), and (19). These terms are defined as 179
fprobe(n; ˆa,ˆb,ˆc,... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 9 |
ec7a3e77-3e9d-465f-b42f-6be069203be5 | SciPy[13] is used to numerically find the minimum of (21). 185
4. SIMULATIONS 186
Multiple sets of simulations are performed to evaluate the performance of 187
the algorithm described in the previous section. The model for the simulations 188
is a 1.3 GHz TESLA-like[14] cavity with a half bandwidth ω1/2= 2π·141.3 Hz 18... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 9 |
4f20719c-0faf-4f35-8686-457624fb93a4 | Journal Pre-proofJournal Pre-proof
Time (s)0.02.55.07.510.012.515.0Voltage (MV)
Forward, from [7], k add= 1
Forward, energy based
Forward, model
Probe
0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00
Time (s) 1e 3
50
050100150200Detuning (Hz)
Detuning, from [7], k add= 1
Detuning, energy based
Detuning, model(a)
(b)Filling ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 10 |
fba2a22e-292b-4f31-929e-ab3d5e5c2062 | Journal Pre-proofJournal Pre-proof
Equation (18) is used to simulate the system with the chosen parameters with 197
a sample rate fs= 10 MHz. A Gaussian measurement noise with σn= 1 kV 198
is added to the simulated traces when evaluating the calibration algorithm. 199
A Gaussian actuator noise with σa= 10 kV is also ad... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 11 |
12ee880e-5831-44ef-8acc-5533aff1ed2f | optimization, it is decided to keep kadd= 1. This choice could result in an 207
unfair comparison with the other methods, but, on the other hand, it puts 208
all the algorithms roughly at the same level in terms of time for executing a 209
single calibration. Additionally, this algorithm is always run with kadd= 1 210
... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 11 |
40066371-2c25-40ce-9b31-01a40b01483f | by doing an exponential fit of |Vp(n)|on the decay period. To compute 217
d|VP(n)|
dtandd|VP(n)|2
dta Savitzky-Golay derivator routine from [13] is used. The 218
parameters used in savgol filter are a window length of 201 and a filter order 219
of 3. This results in a signal bandwidth approximately equal to 62 kHz [15]... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 11 |
7d2b5bce-dcbf-4994-afeb-e5350210feab | generated: 227
1.|Sab| ≈ − 40 dB :in this dataset it is assumed that the conditions of 228
the method from Pfeiffer et al. are fulfilled. A randomly distributed 229
contribution with σc= 0.01 is set on a, b, c, d in every simulation. The 230
average of a, disµa,d= 1, while, for b, c µ b,c= 0. 231
2.|Sab| ≈ − 20 dB :in ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 11 |
8058e9f7-f2b9-4768-9ac2-f593dde77480 | Journal Pre-proofJournal Pre-proof
dataset σc= 0.01. The cavity is simulated with an additional detuning 234
component, applied from the beginning of the pulse to its end, which is 235
normally distributed with σdet= 260 Hz through the different elements 236
of the dataset. 237
Method nRMSE( ωe
1/2) % nRMSE(∆ ωe) %
Non... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 12 |
ca37ff5e-f90e-4be3-97cb-6d568872d425 | |Sab| ≈ − 20 dB case.
Each dataset contains 1024 different cavity simulations. The calibration 238
algorithms are executed on each element of the datasets. Then, the computed 239
coefficients are used to calibrate the denoised cavity signals and estimate the 240
cavity half bandwidth ωe
1/2(n) and detuning ∆ ωe(n) trac... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 12 |
67fc82eb-a789-442b-b956-a385f7c052cf | Journal Pre-proofJournal Pre-proof
|a|
|b|
|c|
|d|
104
103
102
101
Calibration error (a.u.)Diagonal
From [7], kadd=1
A. BrandtEnergy
Energy constr.Figure 4: Average errors on the a, b, c, d parameters for the |Sab| ≈ − 40 dB dataset.
|a|
|b|
|c|
|d|
104
103
102
101
Calibration error (a.u.)Diagonal
From [7], kadd=1
A. B... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 13 |
f05d1bf7-9537-4708-aeb9-ed31bfe6ab79 | Journal Pre-proofJournal Pre-proof
Method nRMSE( ωe
1/2) % nRMSE(∆ ωe) %
None 7.98 8.37
Diagonal 7.69 8.27
From [7], kadd= 1 5.93 6.18
A. Brandt 3.23 8.36
Energy 0.05 33.89
Energy constr. 0.05 0.38
Table 3: Normalized RMSE bandwidth and detuning estimation errors over ω1/2for the
|Sab| ≈ − 40 dB with randomly distribut... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 14 |
2e949f2c-48ee-40c1-9dae-39ed6a0eddb5 | result in a significant nRMSE improvement. The energy calibration, even 250
if results in only a 0.07% nRMSE for the half bandwidth computation, 251
results in an error for the detuning twice as big as the uncorrected case. 252
Fig. 4 shows that for the energy calibration, the average error on the a, b, c, d 253
parame... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 14 |
3d7e8aab-34d9-4242-9580-8a1d6c23e751 | Journal Pre-proofJournal Pre-proof
from [7] is comparable to ω1/2and only slightly better than the uncorrected 258
case. This comes with no surprise since these methods are suited for small 259
to zero values for b, c. For the A. Brandt’s method, the nRMSE is 0.03% for 260
the bandwidth and 0.46% for the detuning. For ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 15 |
a356679e-5e55-439d-8078-326c4b96905e | a detuning trace that significantly deviates from the model in the filling and 268
flattop period but matches it in the decay period. A similar behaviour is 269
found in all the analyzed simulations. This finding motivates a modification 270
of the original version of the calibration algorithm. The constrain of (8) 271... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 15 |
abedc7b6-a30c-4072-93d7-70d9e9fe0635 | and bandwidth is similar or worse than the simple |Sab| ≈ − 40 dB case, 278
the energy-constrained method improves the estimations with respect to the 279
other cases (Fig. 6, Tab. 3). Even when compared to A. Brandt’s method, 280
the energy constrained method achieves more than an order of magnitude 281
higher in term... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 15 |
33573829-e1da-408d-b5c2-9b392f1ef517 | the systematic estimation errors on the bandwidth flatness. However, since 289
there might be other systematic errors on the measurement chain other than 290
the finite directivity of the waveguide couplers, the data analysis only gives a 291
lower bound on the precision of the algorithm. For the analysis, 1024 traces ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 15 |
a36515ba-edaa-4c43-9907-c9ec0a9644ab | Journal Pre-proofJournal Pre-proof
thea, b, c, d parameters. Then, the obtained parameters are used to calibrate 294
all the other measured traces. The estimated ωe
1/2is used to calculate the 295
normalized RMSE( ωe1/2) defined as 296
nRMSE( ωe1/2) =1
ω(0)
1/2√∑
n∈N(∑M
m=1ωe(m)
1/2(n)−ω(m)
1/2
M)2
|N|, (28)
where ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 16 |
f1be4f14-237b-48c9-8cea-0b186de0c95d | None 7.05 14.64
Diagonal 4.39 13.66
From [7], kadd= 1 2.04 13.90
A. Brandt 0.50 0.32
Energy constr. 0.75 0.31
Table 4: nRMSE of the estimated bandwidth with different calibrations at CMTB,
EuXFEL, and AMTF. CMTB and EuXFEL are equipped with 1 .3 GHz accelerating
cavities.
5.1. EuXFEL 303
The measurements at EuXFEL are ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 16 |
40c43c8b-e35d-4f43-9d15-99617a4ee0dd | Journal Pre-proofJournal Pre-proof
Time (s)050100150200250Detuning (Hz)Diagonal.
From [7], kadd=1
A. Brandt
Energy constr.
No correction
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
Time (s) 1e3
130135140145150155160Bandwidth (Hz)Figure 7: Detuning (a) and bandwidth (b) for the EuXFEL cavity, calculated with different
calibrati... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 17 |
c7236718-cead-4e4e-8744-5c338f6a1304 | to the uncorrected case by a factor of 10 and by a factor of 2.7 with respect to 317
Pfeiffer et al. When compared to A. Brandt’s method, the energy-constrained 318
method achieve a similar precision. 319
5.2. CMTB 320
As for the EuXFEL case, the measurements at CMTB are performed on 321
a TESLA cavity. QLis set to 2 .... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 17 |
006d58c0-3cb0-4d63-a847-9c643f9b014d | Journal Pre-proofJournal Pre-proof
Time (s)60
40
20
0204060Detuning (Hz)Diagonal
From [7], kadd=1
Energy constr.
No correction
0.25 0.50 0.75 1.00 1.25 1.50 1.75
Time (s) 1e2
1618202224Bandwidth (Hz)Figure 8: Detuning (a) and bandwidth (b) for the CMTB cavity, calculated with different
calibrations. The measurements ar... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 18 |
71e4e40b-f56e-4d2f-a8ce-9fc2f6d2b560 | Journal Pre-proofJournal Pre-proof
Evaluating the bandwidth with the uncorrected and diagonal methods gives 329
similar results in terms of achieved error. Contrary to this trend, the energy-constrained 330
algorithm performs even better than the EuXFEL case with an nRMSE of 331
0.31%. Also in this case, A. Brandt’s me... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 19 |
2a6cf8d6-524c-4fd3-8095-02da0773ffd2 | (21), the methods found in literature either use a constraint on the magnitude 340
of the cross-coupling parameters ((10) from [7]) or rewrite the b,c,dcoefficients 341
in function of ato perform a single complex variable optimization ((15) for the 342
algorithm from [8]). From the simulations and the experiments perfo... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 19 |
f247713b-310b-4e1d-b301-e4c121cbd6df | pulses. Therefore these results might open new possibilities in using model-based 350
techniques to reliably perform quench detection when a sufficiently low-noise, 351
low-drift LLRF measurement chain is used. Additionally, this technique is 352
particularly useful in high QLaccelerating systems that require an Hz-sca... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 19 |
b029d16a-0817-43f2-a594-308a717bb486 | appendix A). However, it has still to be seen what the consequences are 360
when this reflective element has time-changing properties. Such a situation 361
can occur, for example in Vector-Sum (VS) systems with poor isolation on 362
the circulators. In this case, all the other cavities can perform as variable 363
refle... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 19 |
75af288f-7281-4df3-ad77-2121a2a5d884 | Journal Pre-proofJournal Pre-proof
A. Brandt’s method performs similarly to the presented algorithm. However, 365
simulations suggest that A. Brandt’s method may perform poorly in cases 366
when the calibration is performed on detuned cavities. For the algorithm of 367
[7], the tuning parameter is kept as kadd= 1. Ther... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 20 |
a5878254-3e36-4e02-8c74-478adfe3d85a | and reproducible manner. In appendix B, a Python implementation of the 375
algorithm is given, along with a version of all the other algorithms used in 376
this study. 377
7. ACKNOWLEDGEMENTS 378
We want to thank B. Yildirim and V. Katalev for the information provided 379
for the 1 .3 GHz waveguide directional coupler.... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 20 |
0e7280d9-d8d1-4e02-8933-b0d5c02d4a3c | directivity and VF=Vm
FandVR=Vm
R. Also, the group delay τgof the 387
signal from the cavity power coupler is reflected back at Γ r∈Cis 388
τg≪1
ω1/2. (A.1)
With (A.1) the field inside the waveguide can be approximated as being in 389
steady state with respect to the accelerating field of the RF cavity. Therefore 390
i... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 20 |
122b5e6e-bcb5-4534-bafa-f8404d3b6329 | Journal Pre-proofJournal Pre-proof
r∈Crepresents the fraction and the phase of the field that comes from the 393
reflective element back to the cavity coupler. VF0is the part of the forward 394
signal that is generated by the RF amplifier. Using (A.2) with (6) 395
VF=VF0+r(VP−VF)→
VF=VPr
r+ 1+VF0
r+ 1. (A.4)
The forwar... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 21 |
63a2545c-3c0a-47b6-9cb8-009158a509cd | Therefore, if the system described in (A.6) is calibrated with the energy 402
constrained method, (6) requires 403
VP=VF+VR=V∗
F+V∗
R. (A.10)
Using (A.10) with (A.2) and (A.9) gives a linear transformation from the 404
original cavity signals to the equivalent cavity model which comprises the 405
effect of the reflecti... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 21 |
3787b16c-55f2-4bfd-a68b-83f8303ab4b0 | Journal Pre-proofJournal Pre-proof
{
V∗
F=q(VF−rVR),
V∗
F+V∗
R=VF+VR,→(A.11)
{
V∗
F=qVF−qrVR =a∗VF+b∗VR,
V∗
R= (1−q)VF+ (1 + rq)VR=c∗VF+d∗VR,(A.12)
with
q=ω1/2
ω∗
1/2(1 +r). (A.13)
Therefore (A.12) describes the calibration with parameters a∗, b∗, c∗, d∗of the 407
equivalent system with half bandwidth ω∗
1/2. 408
23 | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 22 |
d04bc004-ddc7-458a-8438-b2a5e6378e08 | Journal Pre-proofJournal Pre-proof
Appendix B. Implementation of the calibration methods in python 409
Here the code for the diagonal, energy methods, and the one from Pfeiffer et al. 410
used in the paper is given. The decay traces in the calibrate energy function 411
have to be assigned to use the energy-constrained ... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 23 |
55279f25-96a1-403d-93aa-6320c1d16fd3 | 9# conditions: 423
10 # 424
11 # The above copyright notice and this permission notice shall be included in all 425
12 # copies or substantial portions of the Software. 426
13 # 427
14 # THE SOFTWARE IS PROVIDED ”AS IS”, WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, 428
15 # INCLUDING BUT NOT LIMITED TO THE WARRANT... | d:\Zotero\sync\storage\ZRLWNT95\Bellandi 等 - 2024 - Calibration of superconducting radio-frequency cavity forward and reflected channels based on stored.pdf | 23 |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.