id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
9e17e099-e535-4316-b37b-31e604a8aeb8
tors”,inCAS - CERN Accelerator School: Beam Diagnostics, pp. 187–228, 2009. doi:10.5170/CERN-2009-005.187 [8]M.A.Rehman,et al.,“Developmentofarectangulardiagonal cut-plane BPM for the CSNS-II injection upgrade”,Proc. IBIC’25, Liverpool, UK, Sep 2025, pp. 645–649. doi:10.18429/JACoW-IBIC2025-WEPCO12 [9]CST, https://www....
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6621.pdf
3
6d5869b7-d175-48c9-9726-7b6d564ab4ec
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6621 MC6.T03: Beam Diagnostics and Instrumentation 469Monday: Poster session MOP6621 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6621.pdf
3
b675afca-7b8a-41b0-9e07-2f92e5b68979
SOFTWARE DEVELOPMENT OF BEAM DIAGNOSTICS READOUT SYSTEM BASED ON A MULTI -CHANNEL HIGH- SPEED DIGITIZER * Z. H. Xu1,2, L. Zeng1,2, F. Li1,2,M. Y . Liu1,2, M. A. Rehman1,2, R. Y . Qiu1,2,W. L. Huang1,2, Z. J. Lu1,2, C. J. Xie1,2, R. Yang1,2, R. J. Yang †,1,2 1Institute of High Energy Physics, Chinese Academy of Sci...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
0
62dd5750-225e-471d-aab4-6aab404dc27e
ilar multi -channel detectors typically utilize multiple PXIe acquisition cards to construct a PXIe -based signal acquisi- tion system, which suffers from high cost and limi ted flex- ibility. This paper presents an alternative signal readout so- lution using a multi -channel high- speed digitizer to replace the PXIe...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
0
1909a351-14d2-4b7c-851e-6fd2151c1248
INTRODUCTION In the upgraded accelerator complex of the China Spall- ation Neutron Source Phase II project, the beam diagnos-tics system employs various multi -channel detectors, such as the Ionization Profile Monitor and the Multi -Wire Pro- file Monitor. Traditionally at CS NS, signal acquisition for such detecto...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
0
d93dfc5b-5d47-40d5-bbf4-4f8b4f9af1d7
cation, eliminating the need for separate analog electronics. Its maximum sampling rate of 125 MS/s is sufficient for the beam pulse widths (80 ns to 500 ns) in the CSNS -II Rapid Cycling Synchrotron. The associated data acquisi-tion and control software, developed in C on the Linux platform and integrated with the E...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
0
b4d51ce8-3440-46d2-8ef9-fc0581626305
high-speed multifunction data acq uisition cards. Each card provides a limited number of analog input channels . To achieve the required channel count for detectors like the Multi -Wire Profile Monitor, multiple such cards are in- stalled within the same chassis[2]. Separate rack -mounted or custom -designed front ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
0
326ce429-4101-45ed-bbe4-9382a4a15048
diagram is shown in Fig . 1. CPUSlot1 DAQSlot2 DAQ DAQ DAQ DAQ DAQ ...PXIe Chassis Slot3Slot4 Slot5Slot6 SlotN Figure 1: PXIe hardware architecture diagram. Multi- Channel Digitizer System The core hardware of the new proposed system is the CAEN DT2745B digitizer. Its key specifications include 64 analog input...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
0
5cc05d67-933b-4d2a-9312-5387c02e8ec0
one compact device[3][4]. The multi -channel digitizer sys- tem diagram is shown in the Fig. 2. ________________________________ ___________ * Work Supported by National Natural Science Foundation of China (NO. 12305166) and the Natural Science Foundation of Guangdong Province, China , (NO. 2024A1515010016) ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
0
ff53268c-f6d1-4473-8e81-7fceab63e0db
CAEN DT 2745 IPCUSB Figure 2: Multi -channel digitizer system diagram. SOFTWARE ARCHITECTURE The software architecture is designed for high perfor- mance, reliability, and seamless integration with the EP- ICS-based control system at CSNS. It consists of three main layers: Driver & Library Layer This foundat...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
1
b7e5a702-cfca-4ac0-a6a7-df3a73a13333
source, gain, etc.), manage a continuous data acquisition loop, and process the incomi ng waveform data. The appli- cation employs producer -consumer threading to separate the data reading/processing logic from the user inter-face/command handling, achieving pseudo -asynchronous data readout [5]. EPICS Integration ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
1
20b1fb85-0a2d-4bbd-81e5-8a742c740b2d
the Fig. 3. EPICS DriverDAQ Figure 3: Software architecture. SOFTWARE COMPONENTS AND FUNC- TIONALITIES To enable multi -channel signal acquisition for multiple IPM, a specialized DAQ software suite has been imple-mented. Configured with a sampling rate of 125 MSPS, a record length of 600 μs, and 64 acquisition...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
1
67daf2f5-7132-40b7-8795-6a6f3f1e38ad
mation factor. Trigger Settings:the source can be set to external trigger, software trigger, or internal test pulse. The trigger level can be set NIM or TTL. Channel Settings: Enabling or disabling channels, setting DC offset, and critically, configuring the front -end ampli- fier gain . Multi- threaded Data A...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
1
79c63c37-01b6-4e83-80fd-dfcd304408f4
version: It reads the channel -specific conversion coeffi- cient and appli es it to the raw ADC data, translating counts into meaningful voltage values. Data Save : Processed waveform data can be saved to disk. The software supports saving all events to a single file with timestamps or saving each trigger event to...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
1
59edf330-4937-41e2-b3b4-5ddbf9f2f25a
The IOC is configured using a template and substitution file to instantiate 64 waveform records, one for each chan-nel. This design provides a standardized interface for the control system to access the high -speed acquisition data [6]. 17th International Particle Accelerator Conference, Deauville, France JACoW Publi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
1
6094a292-50b4-4cd7-a730-329881de12f9
SOFTWARE TEST The complete software system underwent extensive test- ing in the laboratory. Driver and Basic Communication: The CAEN_FELib li- brary and associated drivers were successfully installed and tested on an Ubuntu industrial PC. External and Internal Trigger Modes: The software was validated in both ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
2
d172830d-7bf3-43e8-9b9d-cd7ff1011b4d
simultaneously. The voltage waveform data published by the application was successfully monitored and retrieved in real -time using standard EPICS too ls like caget and Con- trol System Studio graphical operator interfaces. Embedded Operation:The application was cross -com- piled and run successfully on the digitize...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
2
a8654c7f-93d1-4f22-895c-52a110329fd8
A response time test was also conducted. For a trigger frequency of 25 Hz, the response time over a period is shown in Fig. 7. The figure indicates that the response time is consistently around 40 ms. Figure 7: The response time. CONCLUSION A new beam diagnostics readout system based on the CAEN DT2745B hig...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
2
633dd93c-3d0b-483e-a663-57dbb0dea537
time monitoring and data sharing. This system resolves the stability and openness limitations of the prior Lab-VIEW/Windows -based solution and has been validated as a reliable and effective platform for mul ti-channel beam diagnostics signal acquisition at CSNS -II. REFERENCES [1] W. Sheng et al. , “Introduction ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
2
4673435b-817f-4230-b1c2-f6a2f64adede
[6] EPICS, https://epics.anl.gov/ 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6623 472 MC6.T03: Beam Diagnostics and InstrumentationMOP6623 Monday: Poster session Content from this work may be used under ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6623.pdf
2
6778d8a2-9c84-4e33-b150-8eea15184a47
DEVELOPMENT OF ANALOG ELECTRONICS FOR THE BEAM LOSS MONITOR IN THE SUPERCONDUC TING SECTI ON OF THE CSNS II LINAC * L. Zeng1, 2, Z.J. Lu1, 2, R.Y. Qiu1, 2, F. Li1, 2, Z. H. Xu1, 2, W.L. Huang1, 2 M.Y. Liu1, 2, C.J. Xie1, 2, R.J. Yang†, 1, 2 1Institute of High Energy Physics, Chinese Academy of Sciences (CAS),...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
0
bf6368dd-e848-40dc-8d81-45d48b716d96
tection of the superconducting accelerator, the parallel - plate ionization chamber , which has been massively imple- mented to the Large Hadron Collider (LHC ), will be em- ployed. The beam loss monitor electronics is designed with an extremely wide measurement range (200 pA to 20uA ) and requires a machine protecti...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
0
cdf49366-ff56-453f-9932-519cc8b3243b
so the detection of beam loss can only be performed on the outer surface of the cryogeni c module. The overall layout of the CSNS -II linac [1] is presented in Fig. 1 . Due to the thick cavity, it has a significant shielding effect on the sec-ondary radiation generated by beam loss. On the other hand, the need for ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
0
1a36992c-4ee6-445f-aa24-926d1de441a2
will be installed in the CSNS -II linac superconducting sec- tion. Figure 2: Parallel -plate ionization chamber . The CSNS -II superconducting section BLM analog elec- tronics conditions BLM detector output signals and pro- vides interlock signals for machine protection, with detec-tor, current range and electroni...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
0
d91c6be5-7569-4b41-b2ba-5dd1e095e3f3
voltage/frequency signals. Mainstream international BLM front -end analog electronics fall into two types: ESS/SNS/FRIB’s "current -to-voltage" ( IV) conversion and LHC’s "current -to-frequency" (IF) conversion. IF CONVERSION The IF conversion front -end analog circuit is designed with reference to LHC’s beam lo...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
0
eff944fa-9a35-4db6-b26d-c796aec3df8c
which outputs a fixed- width pulse to control the reference current source to discharge the capacitor. The total beam loss charge detected by the ionization chamber is accumu- lated as Qt at intervals T. The Machine Protection System (MPS) is generated by comparing the pulse counter’s count with the calibrated unit-...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
0
3f4bb9cc-9c85-4512-a07e-498e86786018
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6627 MC6.T03: Beam Diagnostics and Instrumentation 473Monday: Poster session MOP6627 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
0
89890de2-296c-41a0-bd7e-d9461b18dca0
Figure 3: The block diagram of IF conversion. The current -to-frequency conversion circuit has the ad- vantages of ordinary integrating amplifier circuits. In addi- tion, since its output signal is a pulse frequency signal, it has better anti -interference ability than voltage signals, which is conducive to long -...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
1
4acd4b82-1a1c-4762-9ec3-3e647e89796d
Figure 4: Photograph of the IF analog electronics . IV CONVERSION The IV conversion front -end analog circuit is designed with reference to the beam loss electronics of the Spallation Neutron Source (SNS) [5]. The circuit is composed of a first-stage variable gain amplifier circuit, a threshold com- parison MPS ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
1
18236851-46f1-41d4-a453-e06f72192f61
requirements of small beam intensity and high beam loss resolution during beam tuning, while the 1 M Ω and other levels are used as a level for machine protection when the machine is in fo rmal operation and large beam loss occurs, which fully meets the response time requirements during machine operation. Figure...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
1
5b61ef14-803e-417b-b591-2fefd4ffe882
integral comparison circuits: the integration circuit broad- ens ring and RTBT hundred -nanosecond waveforms to meet ADC acquisition requirements, with a lower MPS protection threshold for better machine protection. A wave- form display circuit (5 -fold gain, 100 kHz filtering) is de- signed for real -time beam loss ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
1
5b50f381-1b5b-4c1c-8f36-1243e4eeaf9f
shown in Fig. 6. Figure 6: Photograph of the IV analog electronics . BEAM -ON OPERATION TEST To improve the sensitivity of the overall BLM system, the team is carrying out technological modification of the stacked ionization chamber and optimizing the selection of filling gas. In order to verify whether the p...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
1
c895eeea-c0ed-45d9-8b29-651335d9c3dd
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6627 474 MC6.T03: Beam Diagnostics and InstrumentationMOP6627 Monday: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
1
a98d03e3-ac74-47f4-b43b-cfa149c60534
beam loss signal can be clearly detected. The schematic di- agram of beam blocking is shown in Fig. 7 . Figure 7: Schematic diagram of beam interception by a wire. When the detection wire is placed at the beam center, the intercepted beam current is estimated to be approximately 0.1% of the total beam current. ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
2
b904ff0e-db90-4c7f-9e28-a390cab08c9b
After testing, it is found that when the wire is located at the beam center, the IF conversion electronics can identify two consecutive pulses within 20 μ s. The FPGA counts the number of pulses within the time window to determine and generate the MPS protection signal. The output waveform of the electronics is sh...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
2
e08417d5-2212-45a5-91a8-c2161743f557
ber is superior to that of the nitrogen ionization chamber. The output waveform of the electronics is shown in Fig. 10. Figure 10: The output waveform of the IV electronics . CONCLUSION This paper has addressed the critical requirements for the CSNS -II superconducting section by investigating BLM analog el...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
2
c93d1f4c-e558-4b0e-b509-df6fd8896171
detector optimization has been finalized with xenon se- lected as the fill gas for the ionization chambers, owing to its excel lent signal- to-noise ratio. REFERENCES [1] R. J. Yang et al., “Progress of the beam instrumentation de- velopment for the CSNS upgrade,” presented at ICFA Beam Dynamics Workshop (HB2025...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
2
50193b47-9ee8-45a6-b9c7-7e697688795b
[4] E. Effinger et al. , “The LHC beam loss monitoring system’s data acquisition card,” in Proc. 12th Workshop on Electronics for LHC and Future Experiments , Valencia, Spain, Sep. 2006. [5] R. Witkover et al ., “Preliminary Design of the Beam Loss Monitoring System for the SNS”, in Proc. 10th Beam Instruc- tion...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
2
1a5827df-8d99-4c3b-b53a-b4f9e6f9f260
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6627 MC6.T03: Beam Diagnostics and Instrumentation 475Monday: Poster session MOP6627 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6627.pdf
2
52d2fd0e-72fe-4611-838c-ae3b9335899d
APPLICATION OF WALL CURRENT MONITOR AT CSNS RAPID CYCLING SYNCHROTRON∗ F. Li1,2, T. G. Xu1,2, J. L. Sun3, W. L. Huang1,2, Z. J. Lu1,2, R. Y. Qiu1,2, M. A. Rehman1,2, W. W. Chen4, Z. H. Xu1,2, R. J. Yang†,1,2, L. Zeng1,2, C. J. Xie1,2 1Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing, China 2...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
0
d66aa9ce-9794-4d1f-b550-675429f78c48
WCMsystemdesign(probeandDAQ)andrecentbeammea- surement results, including bunch shape evolution, bunch length measurement, and RF frequency tracking during the acceleration cycle. INTRODUCTION TheChinaSpallationNeutronSource(CSNS)isalarge- scale scientific facility located in Dongguan, China [1]. Its accelerator comple...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
0
e80fd13a-6144-49b3-b99e-80e95bce3349
dynamicsstudies. Unlikecurrenttransformersthatonlypro- vide slowly varying beam current, the WCM captures the high-frequency bunch structure directly. TwosetsofWCMsareinstalledintheCSNS-RCS:one dedicatedtobeamdiagnosticsandanotherservingtheRF controlsystem. ThispaperpresentstheWCMsystemdesign, thecustomdataacquisitions...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
0
d5ce7a39-1394-463d-8196-a625201b023d
†yangrenjun@ihep.ac.cnmatched resistor across the gap, the wall current generates a measurable voltage signal proportional to the beam current: 𝑉WCM(𝑡)=𝑅·𝐼 wall(𝑡)≈𝑅·𝐼 beam(𝑡)(1) where𝑅is the matching resistance. Ferrite and nanocrys- tallinemagneticringsareplacedaroundthegaptoextend the low-frequency response...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
0
398647a8-1537-4a9b-96ef-f1b25093485b
(1K101, effective from 1kHz to 100MHz) and two nanocrystalline rings (1K107B, effective from 1kHz to 500kHz). Each ring has dimensions of 𝜙275×𝜙330×25mm. •Signal pickup:Four symmetric cables combined through a power combiner to cancel position depen- dence. The cutoff frequencies are: 𝑓ℎ=1 2𝜋𝑅𝐶gap, 𝑓𝑙=𝑅 2𝜋𝐿(...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
0
0aa7fda6-c8d4-4916-9fef-6d1912121f2a
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6629 476 MC6.T03: Beam Diagnostics and InstrumentationMOP6629 Monday: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
0
c4fc1339-7cfe-443c-a378-17c01c32e170
Table 1: WCM DAQ System Parameters Parameter Value Digitizer NI PXI-5124 Sampling rate 100MHz (max 200) Resolution 12-bit Storage depth 256MB Samples/cycle 2,500,000 Window 25ms Bandwidth (probe) 5kHz – 400MHz The256MBstoragedepthcaptures2,500,000datapointsper cycle, coveringthe full20ms accelerationperiod. Datais publ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
1
e5f39907-d5d6-4111-b3d4-8085f1cbd38a
completeacceleration cycle. The RFsystemis activefrom approximately 1ms to 22.5ms. The WCM signal clearly shows beam injection at ∼2.5ms, progressive amplitude increase during acceleration due to adiabatic bunch com- pression, and sharp drop at extraction (∼22.5ms). Figure 1: Simultaneously recorded signals over one RC...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
1
03e6ffdb-a5e5-4693-a1a1-4b9b74c02680
signalcapturedsimultaneouslywiththeWCMdata,thein-stantaneous RF frequency throughout the acceleration cycle was extracted (Fig. 2b). The measured RF frequency ramps from1.03MHzatinjectiontoapproximately2.44MHzat extraction, corresponding to a revolution frequency range of 0.52–1.22MHz (with ℎ=2). These values are consi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
1
44dd78a4-fa3d-4ecd-ae09-0383c86ad9f9
amplitudeincreaseswhiletemporalwidthdecreases. Near extraction, the bunches are narrow ( ∼120ns FWHM) and intense, with the double-bunch structure clearly resolved. Figure3: WCMsignalatthreeaccelerationphases: (a)in- jection, (b) mid-cycle, (c) near extraction. The mountain plot in Fig. 4 illustrates the continuous evo...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
1
f0a2bbe5-9bca-46ce-93b7-2b9844899675
beamfromthelinachasaninitialbunchlengthof ∼500nsde- terminedbythechopper. AfterRFcapture,thebunchlength increasesto∼290–330nsduringtheearlyaccelerationphase (3–7ms), exhibiting prominent oscillations associated with17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
1
213887d2-7c7d-4be1-9401-db895ede0d54
Figure 4: Mountain plot showing bunch shape evolution from injection (bottom) to extraction (top). synchrotron motion as the bunches undergo longitudinal filamentation. Afterapproximately8ms,thebunchlength decreases monotonically to ∼120ns near extraction, consis- tent with the design expectation [4]. The oscillation p...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
2
98e7e050-bde2-4661-895a-901e6024dfc9
the beamconditions and theWCM measurement system are highlystable. Thiscycle-to-cycleconsistencyvalidatesthe WCM asa reliablediagnostic for routinebeam monitoring and long-term trend analysis during machine studies. Figure6: Bunchlengthmeasurementfromthreeconsecutive acceleration cycles, demonstrating excellent reprodu...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
2
5e088e8a-68ec-4f41-9c4e-ed2b85a13016
two bunches as they undergo RF capture and phase-space filamentation. After 10ms the phase difference stabilizes, indicating that both bunches are well centered in their re- spective RF buckets. This measurement provides a direct diagnostic of double-bunch symmetry and can be used to identify RF imbalance or beam loadi...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
2
e2396197-ff8d-4dc2-b44a-15766162a459
bilities: tracking bunch shape evolution throughout the 20ms acceleration cycle, measuring bunch compression from∼500nsatinjectionto ∼120nsFWHMatextraction, andextractingtheRFfrequencyramp(1.03–2.44MHz)con- sistent with design values. The WCM data has also been successfully used for synchrotron tune extraction (deviati...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
2
df273a04-5790-463a-9b55-ed972b40c738
anddevelopingmulti-bunchresolvedanalysistechniquesfor the power upgrade toward 500kW. ACKNOWLEDGMENT Theauthorsthank theCSNSacceleratoroperationteam for their support during beam measurements.17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 d...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
2
af12bd73-ee18-434f-9888-aac1a9600b43
REFERENCES [1]S.Wang,et al.,“AnoverviewofdesignforCSNS/RCSand beam transport,”Sci. China Phys. Mech. Astron., vol. 54, no. s2, pp. 239–244, 2011. doi:10.1007/s11433-011-4564-x [2]J.L.Sun,F.Li,A.X.Wang,andT.G.Xu,“Designofthewall current monitor system at CSNS rapid cycling synchrotron,” High Power Laser Part. Beams, vol...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
3
7c1233b6-df0d-4a84-bbce-848d37b8c4e3
2019.doi:10.7538/yzk.2019.53.09.1537 [5]M.T.Li,Y.W.An,S.Y.Xu,F.Li,andT.G.Xu,“Application of WCM in beam commissioning of RCS in CSNS,” inProc. IPAC’19, Melbourne, Australia, May 2019, pp. 2545–2548. doi:10.18429/JACoW-IPAC2019-MOPRB02817th International Particle Accelerator Conference, Deauville, France JACoW Publishin...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6629.pdf
3
42580eb6-be63-468c-8256-b86c092a969d
DESIGN OF THE HIGH- SPEED, HIGH -PRECISION AVERAGE BEAM CURRENT AND LIFETIME MEASUREMENT SYSTEM An Wang1,2, X. Yang1, Y. Deng1, Y. Leng†,1 1University of Science and Technology of China, Hefei, China 2Suzhou Laboratory, Suzhou, China Abstract This paper presents a high -speed, high -precision system for mea...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
0
e3859a79-4cc9-4ef0-9b94-6f8598e3bc94
tem achieves measurement accuracy better than 1 μ A at a 1 Hz update rate and 2 μ A at 100 Hz. This high- speed, high- precision current measurement enables rapid and ac- curate lifetime determination. The system provides a criti-cal tool for real -time monitoring of injection efficiency and beam stability, and off ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
0
379ca6c5-ce1f-4c37-bc6d-84a60f072fbf
Beam lifetime is determined by mechanisms including the Touschek effect, residual gas scattering, and quantum diffusion[4]. In routine operation, beam lifetime measure- ment is typically limited to the decay cycle, with a blind spot during injection due to high frequency and short inter- vals. Touschek lifetime extr...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
0
8770533e-d5a1-4905-a112-f5001f0e3da4
2 MHz and μA-level accuracy at a 1 Hz output rate. System performance has been verified through beam experiments at HLS -II. MEASUREMENT SYSTEM SETUP HLS -II is a second -generation synchrotron radiation (SR) light source dedicated to VUV and soft X -ray production, consisting of an 800 MeV linear accelerator in- ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
0
1d2f2f02-96e2-4162-b473-6598f223a763
of both the beam current and beam lifetime can be achieved. System Architecture The overall hardware architecture of the beam current measurement system is shown in Fig. 1. A voltage signal induced by the beam is acquired using an NPCT sensor and conditioned by front -end electronics. The ADC board then sample...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
0
b2b34fd8-edd8-4ff7-8e4e-5c79dbbb278f
programmable logic receives the high -speed data stream, executes processing algorithms, computes the beam life- time. An EPICS IOC, running on the ARM processor under Linux. Figure 2: Signal acquisition processor . ________________________________ ____________ * Work supported by Large -Scale Scientific Fa...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
0
036f2f33-b673-477b-90a7-7190963e904f
The background noise of the processor was measured with the input channel shorted. The ADC operated at a fixed sampling rate of 2 MHz, and various effective data rates down to 1 Hz were obtained by block averaging con-secutive 2 MHz samples. The standard deviation of the out- put data at each eff ective data rate wa...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
1
b0e47f58-6a73-46af-af92-1071e006fcb2
urement. Below 20 kHz, the measured noise deviates sig- nificantly above the theoretical value; above 20 kHz, the two agree well. To investigate the low -frequency deviation, spectral analysis were performed on the measured noise data. Figure 4: Amplitude spectrum of background noise . Figure 4 show s that the n...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
1
0b88831b-f563-4f34-bbe6-2737522f9101
rectly interfaced with the dedicated electronics of the NPCT. Under zero -beam conditions, the complete system noise was presented in Fig. 5 . System noise decreases from 41 μA at a 2 MHz sam - pling rate to 0.9 μ A at 1 Hz. Above 10 kHz, the measured noise significantly exceeds the theoretical value; below 10 kHz...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
1
ef561b8d-0705-4792-8b81-201989650cfc
turbation of the stored beam by the injection system and the subsequent slow recovery of beam parameters can be observed. The stored beam exhibits significant instability, accompanied by sudden losses in beam current. The original low -speed beam current measurement sys- tem, limited by low bandwidth and low data r...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
1
a7144c01-9313-4c39-ab2f-6d53004f837a
Ideal Noise 100105 Frequency (Hz)10-810-610-410-2100102104 100102104106 Frequency (Hz)01020304050 Measured Noise Ideal Noise100105 Frequency (Hz)10-810-610-410-2100102104 4140 4160 4180 4200 Time (s)496.5497497.5498498.5499499.5500Beam current (mA)17th International Particle Accelerator Conference, Deauville, France JA...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
1
b42f2680-8a77-461e-bc57-744cbe30dc6b
Figure 7 clearly records each injection process and re- veals sudden drops in beam current during the decay phase. By performing correlation analysis with the historical da- tabase, the machine parameter variations responsible for these abrupt changes can be traced. BEAM LIFETIME MEASUREMENT The high- speed, high -...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
2
cb3b1b37-bff0-4e11-8ca6-c19fd2c8df32
Touschek lifetime is d ifficult to be reliably constrained under top- up mode. During routine maintenance at HLS - II, the beam is intentionally dumped and then re -injected, producing a wide current variation from zero to several hundred milliamperes. With the proposed system, lifetime measurements can be performe...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
2
36fe94db-7413-4927-9c28-9cdcdc193b05
(below 100 mA) is justified, as the relatively large lifetime values in this region, combined with the 1 s averaging win- dow, lead to proportionally higher measurement uncertain- ties. The fitting results are shown in Fig. 10 . Figure 10: Touschek factor and vacuum lifetime. Based on the fitting curve in Fig. 10 ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
2
9bdda657-5068-4d2c-9daa-2d5c6608c33e
lifetime. Figure 1 1: Beam lifetime during top -up decay cycles . Figure 11 shows the fast beam current measurement suc- cessfully captures the trend of the Touschek lifetime . This capability offers a valuable tool for future studies of the beam lifetime . CONCLUSION This work presents a high- speed, high -...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
2
02ab55af-f05d-4f96-8866-3bc7f919fd26
exploit system potential. REFERENCES [1] Y . B. Yang et al., “Beam lifetime measurement using beam position monitor in SSRF”, High Power Laser and Particle Beams , vol. 24, no. 1 pp. 189 -192, Jan. 2012 . doi:10.3788/hplpb20122401.0189 [2] X.-C. Ai, et al., “Conceptual design report of the Super Tau- Charm F...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
2
54432d4a-6612-407c-acac-33a72e032a95
Touschek lifetime17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6635 482 MC6.T03: Beam Diagnostics and InstrumentationMOP6635 Monday: Poster session Content from this work may be used under the terms of the C...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
2
7f06c937-336a-470c-91ff-08b4e8b3c22c
[3] Y. B. Leng et al ., “DCCT system design for SSRF storage ring”, Nucl. Tech , vol. 30, no. 6, 2007. [4] H. Wiedemann, et al. , “Particle Accelerator Physics ”, Springer, vol. 314, 2007 . [5] A. Wang et al. , “Design Optimization of the HALF Beam Lifetime Measurement System ”, IEEE Trans. Nucl. Sci., vol. 72...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
3
17b1babe-4166-4ab9-93db-1cc72ffe06ea
Processing Platform for Accelerator Beam Measurement and Control” † email address : lengyb@ustc.edu.cn< 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6635 MC6.T03: Beam Diagnostics and Instrumentation 483...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6635.pdf
3
d4cfc6e6-4d87-4660-9fb8-41893c2a506a
OSCILLOSCOPE- BASED TCSPC LONGITUDINAL BEAM DIAGNOSTICS AT HLS -II* Mingdong Ma, Xing Yang, Yongbin Leng† National Synchrotron Radiation Laboratory, University of Science and Technology of China , Hefei, China Abstract The longitudinal density distribution of electron bunches is a critical parameter for evalua...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
0
40b44aa4-b34f-41e5-afd7-22a8640ac905
gle-photon pulses from a Photomultiplier Tube (PMT). Ex- periments conducted at the HLS -II beamline successfully recovered the bunch fill pattern and reconstructed the pho-ton arrival time distribution. To address the measurement errors caused by amplitude fluctuations, a post -processing algorithm incorporating S...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
0
28a68966-990f-4bcd-a597-59106e49b66b
is a parameter of paramount importance for evaluating beam dynamics in storage rings [1]. For longitudinal diag- nostics, dual -sweep streak cameras are traditionally fa- vored due to their sub- picosecond time resolution [2, 3]. However, their inherent deflection scanning mechanisms and limited readout speeds ofte...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
0
b53752fe-f537-4faa-9429-038ef6648ad5
photodetectors paired with dedicated Time -to-Digital Con- verter (TDC) or Time -to-Amplitude Converter (TAC) modules [10]. While these hardware- centric systems pro- cess timestamps rapidly, they fundamentally discard the raw analog waveforms. This reliance on fixed, hardware- level signal discrimination restricts t...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
0
7441db5c-707e-4c3b-bdf8-50e50a77c432
scope for direct raw waveform acquisition, the proposed scheme shifts critical signal processing into the software domain. This "software -defined" architecture allows core algorithms, such as Constant Fraction Discrimination (CFD), to be executed dynamically, thereby circumventing the rigid constraints of traditio...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
0
2fe01954-7ea2-4075-aca8-cb913895e256
by the electron beam passing through the B8 bending mag-net. The extracted light is directed to an optical table via a series of high- reflectivity mirrors. To ensure high -fidelity imaging, two achromatic doublets with focal lengths of 1000 mm and 400 mm are employed to achieve 1:1 imag- ing of the radiation source...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
0
2ec28851-0b3c-4286-894e-9d6df98c7905
cathode precisely positioned at the 1:1 imaging point. To ensure the system operates withi n the single -photon ____________________________________________ † Corresponding author (email: mmd@mail.ustc.edu.cn ). 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-9545...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
0
31003af9-90e4-4abb-bfcd-c5bcbc98516a
counting regime and to optimize the signal -to-noise ratio, the following components are placed upstream of the PMT: Attenuation Module Includes two neutral density (ND) filters (ND 1.0 and ND 3.0) and a motorized six- po- sition filter wheel (Thorlabs FW103) to adjust input inten- sity based on the beam current....
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
1
f3b7f984-bef2-4ee9-a636-9cdd8a1c9854
nel 1 (CH1). For a stable time reference, the revolution fre-quency signal from the storage ring is processed by a digi-tal delay generator (SRS DG645) for phase adjustment and then fed into Channel 2 (CH2). Integrated Control A host computer manages the sys- tem via standard bus protocols. This includes remote con...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
1
155b0d85-6197-4d0b-a647-74a7e5b56bfa
short bunch train (2 bunches) . A total of 400 ms of PMT waveforms and reference signals were recorded for longi- tudinal profile reconstruction. Pulse Characteristics and Time Walk Effect Figure 4 illustrates four typical single -photon pulse waveforms captured by the Photomultiplier Tube (PMT). To provide a cle...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
1
fb98a31c-1f65-456b-8abd-afd721cdb05a
amplitude of the resulting electrical signals. In this context, employing the traditional fixed threshold method for time extraction would cause the relative time at which pulses of different heights cross a given threshold to shift, resulting in the "time walk effect." This artificial tim-ing jitter in troduced by...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
1
bb3d3a7d-b462-4e41-b20f-931bcf4f0a46
and times in CH1. Baseline calibration is performed using the pre -pulse region to obtain the true amplitude 𝑉𝑉𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝. Dynamic Thresholding A constant fraction k (e.g., 50%) is applied to each pulse to calculate a unique thresh- old (𝑉𝑉𝑡𝑡ℎ=𝑘𝑘∗𝑉𝑉𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝). Interpolation Linear interpola...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
1
cea0c6d8-d563-4819-a5ef-b0e20fb652d5
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6636 MC6.T03: Beam Diagnostics and Instrumentation 485Monday: Poster session MOP6636 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
1
03d81483-3b2e-435a-8e13-89893c1d9007
period to generate a high -resolution longitudinal distribu- tion histogram. Figure 5: Post-processing data flowchart . EXPERIMENTAL RESULTS AND DISCUSSIO Macroscopic Fill Pattern Recovery By accumulating single -photon events over 400 ms , the system successfully recovered the macroscopic fill pattern of ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
2
b58dc077-5e08-4627-9f88-a7f57e4ad5f7
At the microscopic level, the longitudinal density distri- bution of individual bunches was reconstructed using soft- ware CFD and time- folding techniques. Fig. 7 presents the longitudinal distribution of the first bunch within the short bunch train. By applying a Gaussian fit to the experimental data, a standard de...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
2
f1409e45-ba0a-4020-bf25-602c4f59b8ca
traction of the intrinsic bunch length. Figure 7: Measured microscopic bunch profile. CONCLUSION This study successfully implemented a cost -effective and flexible oscilloscope -based TCSPC longitudinal diag- nostics system at HLS -II. By utilizing high -speed direct waveform sampling, the system demonstrates ...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
2
60206785-05b3-4f98-9fb1-01f13352f4a2
REFERENCES [1] H.-S. Wang, X. Yang, Y .-B. Leng, Y .-M. Zhou, and J. -G. Wang, “Bunch-length measurement at a bunch -by-bunch rate based on time– frequency-domain joint analysis techniques and its application”, Nucl. Sci. Tech. , vol. 35, no. 4, 2024. doi:10.1007/s41365- 024- 01443- z [2] I.  V . Konoplev, G. Do...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
2
751c6a36-7ff8-4d6b-b6c6-2d79633ec08e
doi:10.1088/0957- 0233/12/11/314 [4] Y. K. Zhao et al. , “Method for solving bunch head-tail over- lapping in HLS -II using a new trigger scanning module of streak -camera measurement system”, ACS Meas. Sci. Au , vol. 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
2
74e3170d-c499-4bee-a28f-bb15536d1717
220, p. 113344, Oct. 2023. doi:10.1016/j.measurement.2023.113344 [5] Y . K. Zhao et al. , “Application and Development of the Streak Camera Measurement System at HLS -II”, in Proc. IP AC'21 , Campinas, Brazil, May 2021, pp. 1942- 1944. doi:10.18429/JACoW- IPAC2021- TUPAB222 [6] V . I. Shcheslavskiy, M. V . Sh...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
3
263c517d-f85c-4635-9b63-ba650fa7535d
Res., Sect. A , vol. 566, no. 2, pp. 762 –766, Oct. 2006. doi:10.1016/j.nima.2006.07.059 [9] M. Brosi, J. Schmand, J. Breunlin, and F. Curbis, “Time -Cor- related Single -Photon Counting for versatile longitudinal di- agnostics at the MAX IV Laboratory storage rings”, Journal of Instrumentation, vol. 20, no. 03, p....
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
3
aaedf18d-7c70-4e37-a394-09abe11cd29e
Trans. Nucl. Sci. , vol. 72, no. 10, pp. 3180– 3193, Oct. 2025. doi:10.1109/tns.2025.3611028 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6636 MC6.T03: Beam Diagnostics and Instrumentation 487Monday: Post...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6636.pdf
3
155b954e-0706-40d0-8e46-d0cece121389
DEVELOPMENT OF A SIMULATO R FOR RING ACCELERATOR ELECTRON BEAM SIGNALS H. Liu, Y . Deng, X. Gao, Y . Leng†, X. Yang, University of Science and Technology of China, Hefei, China D. Wang, National Synchrotron Radi ation Laboratory, Hefei, China Abstract Beam diagnostic systems are crucial for the Hefei Ad- van...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf
0
bea3366a-a9a4-4280-8af2-a7928085e84a
two input ports for feedback signals and four output ports with independently adjustable signal amplitudes and syn- chronous triggers. It integrates a simplified physics model to generate realistic, wideband beam signals with a pulse width of approximately 5 ns, enabling low-cost, repeatable testing without an actua...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf
0
5cde9b42-2cdf-424b-b1e8-5e6b055ab393
enabling previously impossible lab tests—such as evaluat- ing BbB algorithms and measuring FOFB latency/band-width—before the beam is ready. INTRODUCTION As a fourth-generation diffraction-limited storage ring synchrotron light source, HALF is currently under con-struction [1]. The associated beam diagnostic devices...
D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf
0