id stringlengths 36 36 | text stringlengths 1 1k | source stringlengths 42 191 | page int64 0 1.03k |
|---|---|---|---|
d09d2286-4a14-4474-9e91-bf05b1db4aee | closed-loop characteristics of feedback systems require on-
beam measurements inside the storage ring, together with
specific bunch filling modes provided by accelerator facil-
ities, which is extremely inefficient and inconvenient. To address this issue, a beam simulation algorithm is de-
veloped based on a four-outp... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 0 |
4a14a5ca-b193-487e-af8d-48a42e055116 | bunch, the induced voltage on button electrodes can be ex-pressed as [5]:
𝑉
ሺ𝑡ሻൌగమ
ଶగଵ
ఉ∙𝑍∙௧ି௧బ
ఙమ∙𝐼ሺ𝑡ሻ∙మିఋమ
మାఋమିଶఋ௦ఏ , (1)
𝐼(𝑡)ൌொ
√ଶగఙeି(షబ)మ
మమ. (2)
Figure 2 shows the parameters involved, and 𝑄 is the
bunch charge, 𝜎 is the bunch length, 𝛽𝑐 is the beam veloc... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 0 |
dc366118-e1ba-4796-b028-289b8aa517a0 | ___________________________________________
† lengyb@ustc.edu.cn 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6637
488 MC6.T03: Beam Diagnostics and InstrumentationMOP6637 Monday: Poster session
Content f... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 0 |
d264814b-5e40-460f-94a7-62a561d46ea1 | equilibrium orbit. The actual transverse beam position can
be described as [6]:
𝑥ൌ𝑥ఉ𝑥ఌ𝑥 , (3)
𝑦ൌ𝑦ఉ𝑦 , (4)
where 𝑥/𝑦ఉ(𝑠)ൌ𝑎ට𝛽௫/௬(𝑠)cos(𝜑௫/௬𝜑)are dis-
placements due to beta oscillations, 𝑥ఌ is the radial offset
caused by e... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 1 |
97eec0ab-0d59-4369-bb9f-bc8fbab28118 | zero-crossing of the bunch signal is mainly used to charac-
terize the longitudinal position.
Figure 3 illustrates Turn-by-Turn (TbT) transverse and
longitudinal oscillations acquired by oscilloscope during
normal operation of the Hefei Light Source. Once these data are obtained, they are quantized into four-chan... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 1 |
866213f8-9e49-4872-82c5-56fa7787fbe0 | Figure 4 illustrates the dataflow implemented on FPGA
hardware for generating beam simulation parameters. Var-
ious input parameters (e.g., bunch charge, bunch length,
time offsets etc.) are fed into several multipliers and divid-ers and a Floating ‑point IP core (configured to perform ex-
ponential operations). The ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 1 |
caed04e3-2d0e-4834-b2e2-9410eae45d20 | is as follows:
The beam signal is sampled by a high ‑sampling‑rate
oscilloscope, quantized into a 16-bit data array, and
stored in the FPGA’s ROM.
Considering that longitudinal oscillation is realized by
adjusting the read start address of the data, special handling
of the stored data length is required when ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 1 |
d9403466-7c35-40b8-bad5-b37e5323bcdd | 𝑘
,,,ൌ𝑘(േ𝑥േ𝑦 ), (5)
where 𝑘 is a parameter related to the storage ring and pick-
up structure.
The simulation of longitudinal oscillation is achieved by
the “read address offset me thod”. The original bunch
waveform data is stored sequentially in ROM. During nor-
mal output, reading... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 1 |
83fc4ad1-dd0d-4c45-8b74-f984c38b07b8 | SIMULATION AND TEST
Pre-Simulation
Turn-by-turn Oscillation Simulation Pre-simulation
verification of the beam simulation algorithm was com-
pleted on the Vivado platform. A single-trigger output
mode of 16 bunches was used, with the transverse position of each bunch varyin g according to a preset oscillation
curv... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 1 |
e2337b3e-4943-450e-bd74-528b88c2de96 | Comparison of the exported FPGA simulation results with
reference data shows consistency, verifying the correctness
of the transverse oscillation logic.
Figure 6: Simulation for the Transverse Oscillation Algo-
rithm.
The simulation verification of longitudinal oscillation
focuses on the control accuracy of the ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 2 |
b33e5951-3c62-413d-9056-7e89fe99414b | gorithm.
Four-channel Coefficient Joint Simulation Apply-
ing the transverse oscillation amplitude factors and longi-
tudinal oscillation address offsets simultaneously to all
four channels, the simulation outputs a set of four-channel
waveforms containing 16 bunches. Figure 8 shows the transverse oscillation data u... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 2 |
9b8e6dc8-ad6e-4c2c-b5eb-9edfa51b5dd6 | on waveform analysis, the transverse position sequence re-
covered from the amplitude values of the four channels can
match the preset transverse oscillation curve. As shown in
Fig. 8, the result verifies the correctness of the four-channel coupled output, proving that the simulation algorithm can
generate beam sign... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 2 |
e172ed7f-c39b-4ef7-85ca-12e521680050 | was generated instead of 499.8 MHz (that of HALF).
Figure 9: Test platform and preliminary test result.
CONCLUSION
In this paper, we have developed an FPGA-based beam
signal simulator to address the lack of laboratory testing
capabilities for beam diagnostic and feedback systems at
HALF. Two algorithmic approac... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 2 |
3c90eb0a-12c1-4160-a327-097b321d2324 | both transverse and longitudinal oscillations under a single trigger, achieving a longitudi nal time-shift precision of
50 ps. Four-channel coupled outputs were validated to be
consistent with the mathematical model of beam oscilla-tions. Preliminary laboratory tests using a 1Gsps DAC suc-
cessfully generated a conti... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 2 |
30bd3de6-c4f7-449d-9ef0-ea5eea8b3e89 | latency/bandwidth measurements. Future work will focus on implementing higher-speed DACs and RF amplifiers to
achieve a wider range of amplitude adjustment for a
499.8 MHz output signal for HALF, supporting more fill-ing patterns, and integrating ADC feedback to enable full
closed-loop parameter optimization of the ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 2 |
df04f60a-3609-4c9d-903d-13de7a950f65 | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6637
490 MC6.T03: Beam Diagnostics and InstrumentationMOP6637 Monday: Poster session
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 2 |
74380826-8065-4931-a5cc-1ddb6e6b2b59 | [2] L. Zhan, L. Zhao, J. Liu, S. Liu, and Q. An, “Design and test-
ing of a bunch-by-bunch beam position transverse feedback processor”, Nucl. Instrum. Methods Phys. Res., Sect. A , vol.
902, pp. 62–69, Sep. 2018.
doi:10.1016/j.nima.2018.06.026
[3] D. Zhou et al. , “Development of a BPM signal generator for
FOFB ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 3 |
317608f2-9dfb-4a68-90ee-c3f87e98601f | electron storage ring bunch-by- bunch beam diagnostic tech-
niques”, Nuclear Techniques , vol. 47, no. 10, p. 100201, 2024.
doi:10.11889/j.0253-3219.2024.hjs.47.100201
[6] R. Wu, “Measurement and analysis of bunch-by-bunch three-
dimensional positions and transver se profiles in electron stor-
age ring”, Ph.D thesi... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6637.pdf | 3 |
0d9bf1ae-ee0c-4df1-9e2e-711c13f7f7ef | DEVELOPMENT OF A BUNCH-BY -BUNCH BPM MEASUREMENT
SYSTEM AT SSRF BASED ON MACHINE LEARNING
J. L. Pan1,2, L. W. Lai†,3, Y. M. Zhou3, Y. B. Yan3, C. L. Wang1,2, Y. X. Han1,2
1Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, China
2University of Chinese Academy of Sciences, Beijing, Chi... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 0 |
d6dc692f-9c16-460e-b728-82d0084330e3 | BPM electrode signals with high -speed ADCs at a sam-
pling rate of five times the storage ring RF frequency. By
deploying neural network models within the FPGA, the system simultaneously achieves real -time measurement of
the transverse position and longitudinal phase with low la-tency. Beam experiments were conduc... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 0 |
0c2f89e6-08cd-44b6-8aaa-b534b1b27c90 | online real -time measurements of the storage ring's bunch-
by-bunch transverse position and longitudinal phase are re-
quired.
Current mainstream online real -time measurement sys-
tems are primarily based on digital boards. Data acquired by ADCs, with sampling clocks synchronized to the accel-erator machine clock, ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 0 |
eaf26f12-abe4-4515-8377-e5625ab64cf0 | Current bunch- by-bunch transverse feedback systems,
such as the iGp -12 and Libera Bunch- by-Bunch, all adopt this scheme [2]. The issue with this scheme lies in the need
for precise adjustment of the sampling delay, which hin-ders its application in large -scale engineering projects. Fur-
thermore, beam longitudin... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 0 |
2c1a8182-7c33-49b1-96fd-5b08d21a6955 | respectively. The weights and biases are then deployed on
the Programmable Logic (PL) side of the processor FPGA.
The input layer consists of N consecutive sampling
points belonging to the same bunch. The network under-goes offline training using a large dataset of real beam sig-nals to learn the complex mapping f... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 0 |
5ac5c2dd-42dd-421e-9ea5-8ec61bfc80a6 | results demonstrate that the system achieves a bunch -by-
bunch phase resolution of 0.4 ps.
THEORETICAL BASIS
When a bunch passes through a BPM, signals correlated
with the bunch parameters are induced on the button elec-
trodes. The signal on the BPM electrode is given by:
( )( ) ( )( )2
00
2 3exp ,2 2Z S Q tt ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 0 |
135b4884-5356-43c7-885c-cf19a40d867b | ( ) ( )2
00
2 34exp2 2SZ S Q tt ttV
Lc σ π βσ−−= −
(2)
And the transverse position is obtained by performing a
difference -over-sum calculation on the amplitudes of the
four electrode signals: ________________________________ ___________
* Work supported by The National Science Foundation ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 0 |
1d159e40-7aaf-43b0-a2e9-503d1b3b56d0 | ( ) ( )
( ) ( )/
/X AD BC S
Y AB CD SXK VV VV V
YK VV VV V= +−+
= +−+ (3)
Where KX and KY are the horizontal and vertical calibra-
tion coefficients of the BPM, respectively.
HARDWARE OF THE BUNCH -BY-BUNCH
MEASUREMENT SYSTEM
Figure 1 shows the hardware block diagram of the
bunch -by-bunch p... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 1 |
c6b52c37-fe74-47a1-81ea-70e8a148e96f | The full oscillation information is contained within a
bandwidth of ±1/2 RF frequency centered at the storage ring RF frequency. Taking into account both the maximum
ADC sampling rate and the RF frequency, a low -pass filter
with a cutoff frequency of 780 M Hz was selected. The
ADC sampling rate of the system is s... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 1 |
e4560440-0de7-47db-a02c-822a49a03b7c | BUNCH -BY-BUNCH POSITION AND
PHASE MEASUREMENT ALGORITHM
The data processing flow of the system algorithm is il-
lustrated in Fig. 3 . On one hand, the sampling data from the
four electrodes (A, B, C, and D) of the same bunch are fed into a Fully Connected Neural Network (FCNN) to predict the peak amplitude of each... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 1 |
4dac6672-6790-4db2-bfe5-66a6f7029d95 | dinal phase of the bunch. ADC DataFCNN
A+B+C+D FCNNLongitudinal
PhaseTransverse
PositionΔ/Σ
Figure 3: System Algorithm Flowchart.
The block diagram of the FCNN is shown in Fig. 4 . The
network architecture consists of two hidden layers with 10 and 5 neurons, respectively. This design balances model
expressiven... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 1 |
3cf63adb-ef6d-42ac-b7f0-28d637433d68 | ( ) ( ) ( ) ( ) ( )( )( ) 3 2 11 1 2tanh tanh= ++s W Ws B B (4)
( ) ( ) ( )33 3zb= +Ws (5)
Where V is the column vector of sampling data after nor-
malization preprocessin . W(1), W(2), W(3) are the weight
matrices, while B(1), B(2), b(3) are the bias parameters.
To acquire a lar... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 1 |
240f5227-c312-4462-a7b7-f429af03c37e | of phase, it is possible to reconstruct waveform data with an equivalent sampling rate of 1000 GHz.
Furthermore, the BPM four -electrode signals and sum
signals for each bunch were extracted. The waveforms of each bunch were then randomly shifted along the time axis. In this way, a large number of bunch signals with... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 1 |
a65ada86-a163-4db0-90ff-bc25b6694cbd | the origin, t o ensure the output stability of the FCNN at
critical sampling phases, we set the random shifting range
of the signal along the time axis to ±250 ps when acquiring the sample dataset.
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 1 |
003f8e65-8c11-48c6-a3c6-0f45d3235a04 | The performance of the FCNN for predicting bunch- by-
bunch phase on the validation set is shown in Fig. 5. Within
the range of ±250 ps, the mean phase prediction error is
0.5127 ps, and R2 reaches 0.9999.
Figure 5: Prediction error distribution for Phase.
Figure 6 show the performance of the amplitude predic... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 2 |
e2f03c6f-6b76-4686-889a-1bee088e1a50 | at SSRF. The measurement latency is within 1 μs, which is less than the revolution period of SSRF storage ring (1.44 μs). As shown in Fig. 7 and Fig. 8, the turn- by-turn phase
oscillation of a single bunch and its normalized spectrum
are presented.
Figure 7: Turn -by-turn phase variation of a single bunch.
Fig... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 2 |
48eec486-1cdb-4d3a-a4c6-40f1bea7f68c | system for bunch- by-bunch transverse position and longi-
tudinal phase based on machine learning. Beam experi-ments at the SSRF demonstrate that the system achieves a
bunch -by-bunch phase resolution better than 0.4 ps. Future
work will focus on completing beam experiments for the transverse position algorithm, aimi... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 2 |
7dded01a-d76f-4dee-bfd3-1849594eb07b | System in the TLS”, in Proc. IP AC'11 , San Sebastian, Spain,
Sep. 2011, paper MOPO015, pp. 514 -516.
[3] Xu, X.; Leng, Y.; Zhou, Y.; Gao, B.; Chen, J.; Cao, S.,
“Bunch-by -Bunch Three -Dimensional Position and Charge
Measurement in a Storage Ring ”, Phys. Rev. Accel. Beams ,
vol. 24, issue 3, p. 032802 , 2021 ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 2 |
07cf11ff-51f4-42da-bc64-0da8aa34b090 | [4] J, Pan et al., “The development of bunch-by -bunch transverse
feedback system at SSRF based on RF direct sampling ”. In
Proc. IBIC2024 , Beijing, China, Sep. 2024, paper WEP39 ,
pp. 363- 366. doi:10.18429/JACoW- IBIC2024- WEP396
17th International Particle Accelerator Conference, Deauville, France JACoW Pu... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6641.pdf | 3 |
52900041-3f5e-4147-8250-1aeeb78a3a8f | BEAM DIAGNOSTICS SYSTEM FOR HALF STORAGE RING
Y. Leng†, B. Sun, X. Yang, Y. Deng, C. Wang, D. Wang, J. Wang, Q. Wang, X. Ma, T. Zhou,
Q. Luo, A. Wang, L. Tang, University of Science and Technology of China, Hefei, China
Abstract
The Hefei Advanced Light Facility (HALF) is a fourth -
generation, low -energy diffrac... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 0 |
291239de-cdf6-4fcf-beab-6bf0b816578e | HALF storage ring beam diagnostics system, focusing on
the latest development progress of the high -resolution,
high-stability beam orbit measurement and feedback sys-
tem, and the bunch -by-bunch mu lti-parameter diagnostic
system.
SYSTEM OVERVIEW
The Beam Instrumentation system is one of the critical
subsystem... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 0 |
8d666f52-a0c7-476f-9048-dfc7a0dee134 | these requirements, the BI system must be capable of real -
time measurement of key parameters, including beam po-
sition, beam current, lifetime, filling pattern, tune, beam
profile/emittance, bunch length, and beam loss. Further-more, to effectively guarantee the stability of the orbit and
the beam, the system must... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 0 |
4b84a306-ccce-40d6-88c6-e7208147f9bb | FOFB BW 500 Hz 1
MBFB BW 250 MHz 1 Table 1 shows the primary specification of the all sub-
systems. Figure 1 shows the layout of all diagnostics sen-
sors around the entire ring.
The layout of beam instrumentation probes around the
entire ring is shown in the figure below:
Figure 1: The layout of beam instrume... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 0 |
f30e745c-ffe4-4560-bb00-dbedbb0c40b0 | resolution of the fast feedback data (with a sampling
frequency of 20 kHz) must be better than 200 nm; and the
resolution of the turn- by-turn data must be better than
1 μm [1].
To meet the above requirements, a custom designed
DBPM processor using dual pilot tones and high
oversampling ratio technologies have ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 0 |
2d6e4800-0a97-47c3-b600-a7cd9e856318 | †lengyb@ustc.edu.cn 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6643
496 MC6.T03: Beam Diagnostics and InstrumentationMOP6643 Monday: Poster session
Content from this work may be used under the terms of t... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 0 |
d93fb32b-69ed-4705-bc8e-6fb8d4f298db | (right) acquired during the beam injection process, proving
that the measurement results of this prototype can
accurately reflect the actual physical processes and fully
meet the requirements for beam tuning and operation at
HALF.
Figure 3: TBT data (left) and cor responding FFT (right) ac-
quired during the b... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 1 |
48a4919b-947e-471c-b008-5608b89ef5c4 | accumulation during the first day of storage ring tuning and
the early stages.
BEAM CURRENT M ONITOR
Average current monitor adopts Bergoz's in- flange DC
Current Transformer (DCCT) probes, equipped with a customized high -speed (with a maximum sampling rate of
2 MHz) and high- precision (24 -bits) ADC . It can... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 1 |
5382de40-cc1e-4038-be6d-eafe4a79b778 | two times RF freqeuncy) . The system employs a two -point
phase -separated sampling compensation technology to
achieve precise extraction of signal amplitude, completing
the measurement of the charge per bunch and the bunch-
by-bunch lifetime. The relative resolution of the bunch- by-
bunch charge is required to be ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 1 |
c3af2c7e-64fc-4c49-88af-0aebec14ec08 | time within the FPGA. A physical photograph of the
processor is shown in Figure 4 .
TUNE M ONITOR
Two methods for tune measurement are selected ,
including the frequency sweep method and the harmonic
analysis method based on BPM turn -by-turn position data.
It publishes tune measurement results in real time to... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 1 |
096c7b81-fbf0-4bc4-9f11-0943d5b1d8b3 | measurement during non- injection cycles, dedicated strip
electrodes and a differ ential RF front -end are used to
monitor the residual oscillation signal of the beam position,
achieving high- sensitivity, non -intrusive real -time tune
measurement. This scheme avoids interference with the
beam. The resolution of ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 1 |
08266a0d-3d59-4ab1-a9bd-bc89b6759c60 | imaging of the beam profile and acc urate measurement of
the profile size, and is mainly used during the machine
acceptance test phase and the machine study phase.
Figure 5 shows the side view of Xray imaging beamline.
Figure 5: Side view of Xray focusing imaging system
based on Fresnel zone plates .
The seco... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 1 |
f913ab50-da2d-4a6e-8a87-002c184dd283 | simple structure and are easy to debug. They are mainly
used in the early stage of facility beam tuning as 0 5000 10000 15000
turn index-0.500.5horizontal position (mm)
0.1 0.2 0.3 0.4 0.5
normalized frequency0246amplitude (a.u.)
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
IS... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 1 |
6b807936-74c1-4ddc-b131-cf6f1ad97522 | convenient tools for quick monitoring and diagnosis of the
beam's transverse distribution, ensuring that there are
sufficient observation means during beam tuning. The
streak camera is mainly used for the precise measurement
of bunch length and the observa tion and analysis of
longitudinal beam instabilities. It i... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 2 |
57ed2e38-118e-4186-8956-fd664980c3eb | transverse and longitudinal oscillation amplitudes and
calculate the feedback control valu es. A broadband
amplifier amplifies the feedback signals. Two stripline
kickers serve as the transverse feedback actuator, and a cavity kicker serves as the longitudinal feedback actuator,
forming a complete feedback link to ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 2 |
2c97e02b-a1b8-430f-b6da-851922f99c5a | architecture of MBFB system [3].
Figure 7: Architecture of MBFB system .
FAST ORBIT FEEDBACK
Among the 240 BPMs used for closed -orbit
measurement around the ring, 80 high -stability ID BPM
probes located at both ends of the straight sections are selected exclusively for fast orbit feedback to ensure real -
ti... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 2 |
b33ffc48-0577-4398-b171-a7e1e11fe84b | are interconnected via a redundant dual -ring topology to
form a dedicated network for data exchange around the
ring. All orbit correction values are indep endently
calculated within the feedback controllers. The total delay of the entire system is less than 160 μs, and the feedback
data refresh rate is 20 kHz, ens... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 2 |
ccac13e7-9b94-4276-a483-89117f83c5e3 | troubleshooting of beam loss, and ensuring the safe
operation of the storage ring.
CONCLUSION
All engineering designs for the HALF storage ring beam
diagnostics system have been completed, and batch manu-facturing of the equipment has commenced. The installa-
tion and commissioning are scheduled to be finished by ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 2 |
3919d13b-4648-44e5-9dd8-a5417bfe625c | Measurement System”, presented at the IPAC'26, Deauville, France, May 2026, paper MOP6635, this conference.
[3] X. Yang, Y. Leng , and Y. Deng , “R&D of the Bunch-by-
Bunch Feedback Processor Prototype for HALF ”, presented
at the IPAC'26, Deauville, France, May 2026, paper
MOP6682, this conference.
17th Inter... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 2 |
834534d9-d4dd-438a-bf52-9518032bd9c9 | [4] D. Wang , Y. Leng , Y. Deng , et al. , Research and Development
of Fast Orbit Feedback System at HALF storage ring, pre-
sented at the IPAC'26, Deauville, France, May 2026, paper
WEP6606, this conference.
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6643.pdf | 3 |
c084562c-76a6-4bd9-9e7d-738e71da96d5 | THZ-DRIVEN DEFLECTION OF ULTRASHORT ELECTRON BUNCH
Li Sun∗, Chengzhe Wang, Zhicheng Huang, Yelong Wei
National SynchrotronRadiation Laboratory,
University of Scienceand Technologyof China,Hefei,China
Abstract
Accurate characterization of longitudinal properties in
ultrashort electron bunches constitutes a fundamental p... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 0 |
77f14a65-325b-44d7-aca7-75f0969107b7 | velocity andwavevelocitytogenerate sustainedtransverse
deflectionforces. Thismethodsuccessfullyreconcilesthe
inherent constraints of optical laser bunch length and radio-
frequencyinputpower,whileachievingscalabletemporal
resolutionfrom10femtosecondstotheattosecondregime.
Simulation results validate that the proposed s... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 0 |
307fc254-5b9a-433e-92b3-fff43c57db9e | laser (FEL), dielectric laser accelerator (DLA), laser-driven
(LWFA) and bunch-driven plasma wakefield accelerator
(PWFA) [1–6]. The X-band (11.4 GHz) TDS with compact
design have demonstrated its ability to achieve femtosecond
and sub-femtosecond longitudinal resolution , the recent
experimentsevenshowthatsub-femtosec... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 0 |
45d2cdfe-bc75-4cfd-9dde-221f34bcaa52 | tudinal information of an ultrashort electron bunch which
canbeintegratedonchip. Thoughaccuratecontroloftwo
incident THz laser pulses’ phase shift to 180 degree, the
bunch channel constructed by symmetric dual prisms can
generate a continuous synchronized deflecting force. In a
∗sunli27@ustc.edu.cntwo-dimensional model... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 0 |
235cd91f-8d0e-454b-983b-431aa67c2c62 | STRUCTURE DESIGN
The schematic diagram of the proposed THz-driven elec-
tronbunchdeflectingschemeisshowninFig. 1. Thedesign
leveragestheuniqueadvantagesoftheTHzregime,which
bridges radio frequency and optical domains, to achieve
both extended linear interaction lengths and higher than
femtosecond-leveltemporalresolutio... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 0 |
3fa3c4b0-56cb-4a45-9ccb-727c5141e222 | 180°, which causes the longitudinal acceleration electric
fields (𝐸𝑧) along the axis to cancel each other out, while
the transverse deflection electric fields ( 𝐸𝑥) are superim-
posed. Phase-matching between the electron velocity 𝛽𝑏
and surface wavephase velocity 𝛽𝑝is achievedbyoptimiz-
ing the prism refractive... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 0 |
d1af74ee-d9ce-4572-9cff-221f3ae9e14e | thetimedelay,and 𝜔0thecentralangularfrequency. Figure.
2(a) shows the temporal profile of the THz pulse, with a
pulse duration of 2 ps, while Fig. 2b shows its frequency
spectrumcentered at0.25 THz(bandwidth: 0.22THz).
The electron bunch with Gaussian distributions in both
transverse and longitudinal directions is emp... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 0 |
d663d0e2-900c-4877-8ec4-cdb5d8a1667c | Figure 1: Schematic diagram of the proposed THz-driven electron bunch deflecting scheme. Key components include:
(i) lithium niobate (LN) crystals for THz generation; (ii) symmetric silicon prisms with a 300 𝜇m bunch channel (iii)
180°phase-shifted, parallel-polarized (P) THz pulses. Here, 𝑘and𝑛𝑘denote the vacuum a... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 1 |
4523a13f-685f-41d6-a0d8-95a748c5c8da | together withthe particlesource, aregiven inTable1.
SIMULATION AND RESULT
Thedistributionofdeflectionfieldinthechanneliscalcu-
lated by FDTD algorithm. In the simulation, the transverse
distribution of the THz pulse is set to be uniform, ensur-
Table1: Drivenopticalsourceandparticlesourcesimula-
tion parameters.
Physic... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 1 |
2f272ceb-f363-4c6d-bf4a-23e7d23bd1a4 | propagating in the channel at two moments.(b1, b2) Field
maps of the𝐸𝑥field in the bunch channels at two moments.
(c1,c2)Distributionof 𝐹𝑥/𝑞fieldsalongthez-axisattwo
moments.
Figure3capturestheTHzpulseevolutionat 𝑡1=10.985
ps and𝑡2= 22.076 ps. The electric field magnitude (Fig. 3a)
exhibitsconfinementwithinthepr... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 1 |
b01a42c5-9cef-45e9-9199-a13aa14139ec | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6644
MC6.T03: Beam Diagnostics and Instrumentation 501Monday: Poster session MOP6644
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 1 |
3dfb5a8d-eaa6-447d-afb1-46511da167e4 | �� 0 100
z (μm)-500�x (μm)(a1)
�� 0 100
z (μm)-500�x (μm)(a2)
�� 0 100
z (μm)��0100x (μm)(a3)
�� 0 100
z (μm)��0100x (μm)(a4)
�� 0 100
z (μm)��0200x (μm)(a5)
-50 0 �
x (μm)��00.2x0 (mrad)(b1)
-50 0 �
x (μm)�01x0 (mrad)(b2)
�� 0 100
x (μm)�01x0 (mrad)(b3)
0
x (μm)�01x0 (mrad)(b4)
�� 0 200
x (μm)�01x0 (mrad)(b5)
0.10.20.... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 2 |
1a495488-5042-492b-b997-c516f3b31eab | MeV bunch velocity 𝛽𝑏=0.941within 0.1 %error. The
linearregion( 𝜆/4≈300 µm)aroundthezero-phasepoint
enables uniform deflectionfor 60 µm bunch length.
Figure. 4 tracks the bunch’s phase space evolution at five
timeslices. Thelongitudinalprofileoftheelectronbunch
is observed to exhibit negligible variation. Meanwhile,... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 2 |
9ef57799-0f64-42f9-9012-82c7fd805680 | tribution(𝜎𝑥5=76.66µm)isdirect. WhentheTDSisoff,
the bunch transverse size and longitudinal length is 11.03
µm and 59.40 µm, respectively. Under this condition, the
temporal resolution of the THz-driven dielectric deflector
canbe estimatedto ≈16fs.
CONCLUSION
In conclusion, we propose a particle deflecting scheme
usi... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 2 |
b3ea8f81-922e-4962-8ee2-04f75997c52b | incidentlaser. ThisTHz-driven dielectric particledeflector
is significant not only for femtosecond-level bunch diagnos-
ticsbutalsospatiotemporalshapingofelectronwavepackets,
withwideapplicationsinultrafastelectrondiffractionand
attosecond science.
REFERENCES
[1]L. Sunet al., “GV m-1on-chip particle accelerator driven ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 2 |
99f0476f-67c4-4dbd-99b7-96884292eb56 | deflectionstructure”, ScientificReports,vol.11,no.1,p.3560,
Feb. 2021. doi:10.1038/s41598-021-82687-2
[4]P. Craievich et al., “Novel 𝑋-band transverse deflection struc-
ture with variable polarization”, Phys. Rev. Accel. Beams,
vol. 23, no. 11, p. 112001, Nov. 2020.
doi:10.1103/PhysRevAccelBeams.23.112001
[5]S.P.Jamis... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 2 |
f7dbe24b-e586-4eab-b3f9-7a75b6657717 | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6644
502 MC6.T03: Beam Diagnostics and InstrumentationMOP6644 Monday: Poster session
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6644.pdf | 2 |
46b7ef2a-2c94-40e6-9c57-77ee16ea0e7a | EXPERIMENTAL VERIFICATION OF ENERGY DEPENDENCE IN A CNT
WIRE MONITOR FOR BEAM PROFILE MEASUREMENTS IN THE J -
PARC LINAC*
T. Miyao, KEK Accelerator Laboratory, Tsukuba, Japan
A. Miura, K. Moriya, Japan Proton Accelerator Research Complex, Tōkai Mura, Japan
Y. Liu†, High Energy Accelerator Research Organizatio... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 0 |
6e7a3682-d29e-43a7-8886-9cffbb39fcdb | they have operated without replacement due to beam -in-
duced damage, demonstrating excellent durability. In this
study, we report beam profile measurements obtained with
the CNT WSM at various beam energies.
INTRODUCTION
The J-PARC consists of three accelerators (Linac, 3 -GeV
Synchrotron (RCS), and 50 -GeV... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 0 |
2b067143-3c00-487c-90f0-093fe7d49ae2 | reaches 50 mA. Beam tuning is indispensable for realizing
high -intensity beam operation with minimal beam loss. A
wire scanner monitor (WSM) is one of the most important
diagnostic devices because it is used to determine a current
settings of quadrupole magnets (QMs) for optimizing a
transverse beam profile. A WS... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 0 |
3b9a5158-eff6-4569-89f5-2978ca18ac5f | measurements using the CNT wire in the J -PARC Linac.
WSMS FOR PERFORMANCE
EV ALUATION
In the J -P ARC Linac, three beam dumps, shown in Fig ure
1, are used for high -intensity beam tuning. The 0 -degree
dump has a limited beam power capacity of 0.6 kW;
however, because it is installed on the straight beamli... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 0 |
7f0147f9-ee6e-4f9a-b553-d736b21700a7 | 0-degree dump beamline and has been investigating its
energy dependence. However, because the accelerator is primarily used for user operation, it is difficult to secure
sufficient beam time for dedicated beam tests.
Figure 1: Layout of the J -PARC Linac .
For the development of beam diagnostic devices for
h... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 0 |
c23c8da7-66a4-4aa7-a248-70b3fe73b8ff | _______________________________________
* miyao@post.j -parc.jp
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6650
MC6.T03: Beam Diagnostics and Instrumentation 503Monday: Poster session MOP6650
Content... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 0 |
e4ff406e-fbe0-4533-9960-f5bc6b39cb64 | RFQ and the chamber, a WSM, three beam position moni-
tors, and a current transformer (SCT) are located.
Therefore, detailed measurements with the 3 MeV H⁻
beam using the CNT wire were carried out with the WSM installed at the RFQ -TS, while the beam -energy -depend-
ence measurements were performed with the WSM in... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 1 |
ef6c5c9f-92f6-4fce-a927-b84dc974d00a | the WSM signals obtained for beam pulse widths from 50
to 500 µs.
Figure 3: WSM signals at 10mA beam pulse 50 -500µs.
Up to a macropulse width of 200 µs, the acquir ed
waveform simply becomes longer. However, for pulse widths of 250 µs and above, the signal, which had
previously been negative, increases in ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 1 |
6669b0c4-c3a9-4e22-a752-37ea633cc280 | is carried out using beam pulse widths in the range of 50 –
100 µs. By scanning the wire position, the transverse beam profiles shown in Fig ure 5 were obtained. For the 3 MeV
beam, the beam profile was measured as a negative signal.
Figure 4: SCT signals at 10mA beam pulse 50 -500µs.
Figure 5: Beam profile m... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 1 |
6cf352e4-5b40-4185-abe1-ef6936c41841 | the RFQ -TS study, a beam pulse width was limited to 50
µs; therefore, signal inversion due to thermionic emission did not occur. This suggests that the mechanism of current
induced in the CNT differs between the low -energy and
high -energy regions.
Figure 6: Beam profile measurement at 76 and 400 MeV .
17th I... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 1 |
22f51545-a521-4cd4-9275-6058fab0f53b | Energy Dependence
Figure 7 shows integrated beam -profile signals at each
beam energy. For comparison, integrated WSM signals ob-
tained using a 50 -µm-diameter tungsten wire are also pre-
sented. For a tungsten wire, a consistently negative signal
was obtained regardless of beam energy. In contrast, for a
CNT wir... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 2 |
87f78829-2cad-4e8c-b934-eeb23e527bc4 | electron stripping easily , and the number of stripped elec-
trons exceeds that of emitted secondary electrons [5].
Consequently, the WSM current signal becomes negative.
In the energy range of 171 –181 MeV , the numbers of
stripped electrons and emitted secondary electrons are
comparable. Above 181 MeV , the nu... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 2 |
fe982477-4105-4611-8875-2c3f7d39a467 | wire consistently produced a negative signal, the CNT wire exhibited a signal inversion around 171 –181 MeV . Further -
more, because the signal becomes nearly zero in the 171 –
181 MeV region, it was found that a WSM using a CNT
wire cannot be used f or beam -profile measurements.
REFERENCES
[1] “ Accelerator... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 2 |
9316b44d-7560-4891-943e-d6ba6c4aeebc | bon Nanotube Wire for Beam Profile Measurement of Neg-ative Hydrogen Ion Beam”, in Proc. IPAC'18, V ancouver,
Canada, Apr.-May 2018, pp. 5022-5025.
doi:10.18429/JACoW -IPAC2018- FRXGBD3
[4] Y . Kondo, T. Morishita, Y . Sawabe, S. Y amazaki, T. Hori,
and A. Takagi, “Beam Test of a New RFQ for the J-PARC Linac”, in ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 2 |
fd422df6-0c6f-4712-b409-a6e9a59813bf | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-MOP6650
MC6.T03: Beam Diagnostics and Instrumentation 505Monday: Poster session MOP6650
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), tit... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6650.pdf | 2 |
1ef7c094-3dfc-4f51-a9b6-8d9bf862dcb7 | DEVELOPMENT OF NON-DESTRUCTIVE EMITTANCE TUNING
SYSTEM UTILIZING SYNCHROTRON RADIATION MONITORS
Y. Seimiya∗, N. Iida, T. Mori, High Energy Accelerator Research Organization, Tsukuba, Japan
Abstract
In SuperKEKB, the emittance of the injected beam is an
essential parameter that significantly affects the injection
rate. ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 0 |
93870dc4-08d1-4a5d-ac4b-ff3279465358 | to emittance drift, deteriorating injection rate. To address
this issue, we have developed a non-destructive emittance
tuning system utilizing Synchrotron Radiation Monitors.
INTRODUCTION
SuperKEKB is e-/e+ collider for high energy particle
physics in KEK. Recent operation is as described in the
following report [ 1,2]... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 0 |
e2c78b43-18bf-4a3d-bad2-3614170795e1 | qualitybeamtothemainringwithoutemittancedegradation
as far as possible. Otherwise, the injection rate would be
worse and the luminosity would not be able to reach the
target value.
Figure1: Requiredandaveragedmeasuredbeamparameters
at BT1 in April 2026 for SuperKEKB injector LINAC. The
energy spread value is the value ... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 0 |
f7cd2222-d759-40dc-beee-43800576003f | extractedfromtheendofSector2totheLTRlineat1.1GeV
andinjectedtotheDR.AftertwocyclesoftheLINACpulse,
thedampedbeamis,throughtheRTLline,resumedtothe
startofSector3intheLINAC.Positronbeamisaccelerated
upto4GeVandtransportedthroughthepositronBTlineand
finallyreachesthelowenergyring(LER).Lowemittance
electron beam is acceler... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 0 |
6cac91a3-fe14-4af9-9e0c-22b0284d783c | emittance. The emittance growth in the LINAC cause a
reduction of injection efficiency. Since beam lifetime of
SuperKEKBringis muchshorter thanKEKB, injection ef-
ficiency affects total beam current of the ring. Therefore,
emittance fluctuation sometimes causes reduction of the Su-
perKEKB performance, luminosity. Main... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 0 |
ed556de0-c542-4d3c-901d-23b79e3dd117 | fix the orbit at the region completely.
Asanexample,orbitdriftsoftwonearbyBPMswasfound
attheentranceofJ-ARC.Theorbitaldifferenceshiftedby
about 0.1 mm to 0.2 mm over a few days. To verify the
effect of this orbital difference on emittance, we reproduced
this orbital difference by changing the upstream steering
magnetdu... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 0 |
0418327a-91d9-43f9-a2d0-d56871932091 | the 0.1 mm orbital difference causes emittance growth of
approximately 70 𝜇m, which is non-negligible value.
As an interesting example, we present a phenomenon
inwhichthebeamhasdoublepeaktransverselyevenona
straightsectionwheredispersionnormallydoesnotoccur,
due to a wake field generated by the orbit. As the beam
char... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 1 |
de1c21e0-53cd-40e7-bd49-66536232e728 | On the other hand, Fig. 3shows not only that a double peak
isobserved,butalsothatthereisaz- 𝛿dependenceinwhich
energypeaks appear at the head and tail of the beam. Mean-
while, the beam is kicked by transverse wake field, which
makesx-zdependency. Thedependenciesonbothz- 𝛿and
x-zeventuallyleadtotheemergenceofadepende... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 1 |
f2b1a9c5-5aa8-4ad9-a779-e5669d37b2fd | shown in Fig. 5. The double peak beam phenomenon
disappeared by only the orbit tuning, and the emittance was
alsosignificantlyimproved. Inprinciple,thisdoublepeak
beam issue can be mitigated using the energy spread tuning
by changing the RF phase; however, this does not provide a
fundamentalsolution. SinceRFphasesareke... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 1 |
f5cb0898-cf9b-42eb-9013-09493a327cc6 | differenttransversepositionandtransversemomentumfrom
the beam head. As a result, emittance growth occurs for the
wholebeam. Conversely,ifwecanfindasteeringmagnet
parameters set which minimize the beam sizes at the SRMs,
this is equivalent to minimizing the difference in position
and momentum between the beam head and t... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 1 |
3966b8a3-0978-4896-9f86-cc650647e1f0 | vergence rate. Recently, the downhill simplex method is
selected for stable injection. The objective function is as
follows:
Σ𝑖𝜎2
𝑥,𝑖/𝛽𝑥,𝑖+wΣ𝑖𝜎2
𝑦,𝑖/𝛽𝑦,𝑖
𝑄2
Linacend/𝑄2
RF gun, (1)
where𝜎isbeamsize, 𝛽is𝛽function,𝑖 = 0,1corresponded
to SRM0 and SRM1, 𝑄is bunch charge, and w is weight.
Since vertical... | D:\Daily_ihep\Conferences\IPAC2026\MOP\MOP6653.pdf | 1 |
Subsets and Splits