id
stringlengths
36
36
text
stringlengths
1
1k
source
stringlengths
42
191
page
int64
0
1.03k
41d7be54-b8fe-4821-9cb1-fe28533329a3
frequency and the uniform field profile. Tuning was per- formed with pushing and pulling on the stainless -steel tun- ing studs in both cells. The bead pull test was performed after each roun d of tuning until a balanced field profile was measured in the two cells. Final measured characteristics were in good agreemen...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
1
6bb95a84-50fd-4136-b7f3-45a95743275c
CERF -NM C -band high gradient testing facility at LANL. A photograph of the test setup inside of the lead box that provides radiation protection is shown in Fig. 5. The power to the cavity is supplied by a 50 MW C -band klystron from Scandinova Systems. The diagnostics on the test stand in- cludes the directional...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
1
6476aa7d-45c1-4e00-abcd-d6f581bd2d58
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7313 MC7.T06: Normal Conducting RF 1551TUP: Poster session TUP7313 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pu...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
1
11446933-0c0f-46a9-b57d-5d47f502e721
recorded at the beginning of May and the corresponding computed gradient and the peak fields in the cavity com- puted with the MATLAB script based on the measured in- put and reflected power. Table 2 summarizes the measured conditions and peak fields. At the time of writing this pa- per, the cavity was conditioned u...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
2
9ee2b481-03b7-4c87-9aa2-35e14ceffd62
Frequency 5.7119 GHz Ohmic Q 14274 Pulse length 700 ns Repetition rate 10 Hz Maximum input power 2.63 MW Achieved gradient 63.3 MV/m Peak electric field 170.8 MV/m Peak magnetic field 184.7 kA/m CONCLUSION In summary, this paper reported the status of the experi- ment that aimed to fabricate and...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
2
25aeee36-4170-40ac-82c4-140d514bedaf
downs and the pulse heating due to high electromagnetic fields. The cavity was designed, fabricated, cold -tested and tuned, and is currently installed at LANL’s CERF -NM C - band high -gradient structure testing facility for high -power testing. Upon the completion of high- gradient testing the cavity will be inspe...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
2
5bd370b7-d2e1-48cb-82aa-ac2a2add375c
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7313 1552 MC7.T06: Normal Conducting RFTUP7313 TUP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any dist...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
2
f294298c-2237-4c17-b365-f25fa50178c0
REFERENCES [1] E. Nanni et al. , “Status and future plans for C3 R&D ”, J. In- strum. , vol. 18, no. 9, p. 07053 , 202 3. doi:10.1088/1748- 0221/18/09/P09040 [2] W. H. Tan et al. , “Emittance preservation in the C3 main lin- ear accelerator ”, Nucl. Instrum. Methods Phys. Res. A , vol. 1080 , p. 170660, 202 5. ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
3
aae0399d-ee27-4192-902d-d2e3a701cd0f
Italy, May 2023, pp. 2053 -2056. doi:10.18429/JACoW- IPAC2023- TUPL136 [6] E A. Alexander et al. , “Update on the status of the C -band high gradient program at LANL”, in Proc. IP AC'23 , Venice, Italy, May 2023, pp. 2057 -2060. doi:10.18429/JACoW- IPAC2023- TUPL138 [7] H. Xu et al. , “Design of a two -cell...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7313.pdf
3
ef6a62fd-c595-4fde-ba7f-9f740e4783ab
STATUS OF THE CARIE HIGH GRADIENT PHOTOCATHODE TEST FACILITY AT LANL* E. I. Simakov†, W. Choi, W. B. Haynes, S. S. Kurennoy, V . Pavlenko, D. Rai, T. Tajima, H. Xu Los Alamos National Laboratory, Los Alamos, NM, United States Abstract This paper reports on the status of assembling and com- missioning of...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
0
933b5c1a-f282-41a0-bb53-0d82bea408d9
erating structures). The 50 MW 5.712 GHz Canon klystron powers the facility. The klystron was installed and condi- tioned in 202 3. The output of the klystron is connected to a circulator that was conditioned to operate for up to 12 MW of power. The WR187 waveguide line brings the power from the circulator into a c...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
0
4a1de582-1280-4992-b328-f812cc6cf761
power testing of the injector . INTRODUCTION At Los Alamos National Laboratory (LANL), we con- duct high gradient C -band accelerator studies motivated by multiple LANL projects and future mission needs. For ex- ample, LANL proposed a high gradient C -band upgrade to Los Alamos Neutron Science Center ’s (LANSCE) p...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
0
1f4d38d5-970c-402d-8295-40b3520ea07d
longer, multi -cell accelerating structures is also desired [4], which would result in production of energetic dark current that prevents testing these structures in a test stand with limited radiation protection such as LANL’s C -band Engi- neeri ng Research Facility in New Mexico (CERF -NM) [5]. The construction ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
0
10bcfcdd-92dc-462f-b150-e2388fb1d663
waveguide line. The photoinjector that is currently in-stalled at the end of the line has a non- removable copper photocathode. Commissioning the photoinjector to its full operational parameters will verify the operational function- ality of the constructed CARIE facility for testing of the high gradient structures. ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
0
d97556af-f5c6-4238-a4ef-72eb2c9c195c
was fully conditioned to the peak output power of approx- imately 30 MW with 30 Hz repetition rate limited by the ________________________________ ____________ * This work was supported by Los Alamos National Laboratory’s La- boratory Directed Research and Development (LDRD) Program. † smirnova @lanl.gov 17th...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
0
3c740d35-9e4e-4c5e-b845-2ca1b058a47c
cooling capacity of the available chiller. The waveguide line to the high -power circulator on the roof of the vault was assembled and conditioned in early 2024. The circula- tor was conditioned up to 12.5 MW of power, its operation limited by the SF6 pressure inside of the circulator that had to stay below 25 psi...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
1
a8c8b5fb-7c15-4210-8a31-5dc2124b4415
Filling time, 2 τ 665 ns Power for 100 MV/m cathode field 1.64 MW Power for 240 MV/m cathode field 9.45 MW Power for 240 MV/m cathode field in 1 µs long pulse 10.46 MW Final beam energy for 240 MV/m cathode field (lowest emittance) 6.67 MeV Emax/Ecath 1.28 Hmax*Z0/Ecath 0.882 The remaining waveguide l...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
1
5f6a65a0-abca-465b-b487-3f4affae387f
Operation of t he CARIE facility will be first tested with a 1.6-cell C -band high- gradient RF photoinjector . The goal Figure 3: A photograph of the RF injector installation at the end of the waveguide line (top); a photograph of the RF injector covered with the lead igloo for radiation protection (bottom). ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
1
14b5253a-9db9-4412-acca-ebc7b3dd2e3d
is required to operate this photoinjector at 240 MV/m cath- ode field at room temperature with a 1 µs pulse length . The CAD model of this RF injector and its cross -section is 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.1842...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
1
a456260f-c98a-499c-9723-081962af83d5
shown in Fig. 2. Its dimensions and computed electromag- netic characteristics are summarized in Table 1. The all-copper RF photoinjector was fabricated by Dy- menso, LLC and delivered to LANL in F all of 2023. The injector was cold -tested and tuned to achieve the correct coupling frequency and the uniform field...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
2
6ac3f1a7-32a0-414f-925c-fd61672dc208
was attached to the output beam port which included a movable YAG screen for imaging the dark current and the Faraday cup. Radiation safety simulations were conducted with MCNP code [9] for this configuration to ensure adequate radiation protection with the expected dark current pro-duced during the conditioning. ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
2
46be6a4b-44e3-4c30-b5de-ef844f75af21
neutrons was also considered for this operation due to the neutron generation threshol d in copper of approximately 5.7 MeV and found to have a negligible contribution to possible radiation doses. Two scenarios were model led with MCNP. In the first scenario, the injector was posi- tioned on the steel optical table...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
2
03adb5ee-68fb-415e-8f31-17f8acdecb9f
Simulations suggested that addition of the shielding lead igloo brought the dose rates throughout the experimental building to near background levels with the exception of the roof of the building and the roof of the CARIE vault. The highest dos es expected in both scenarios w ere found on the roof of the CARIE vau...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
2
a416ad66-f201-46f3-b5fa-4e04b917ce43
from the REDA, the lead igloo was constructed around the injector [Fig. 3 (bottom) ]. Conditioning of the injector is allowed to commence once the appropriate interlocks are implemented. Figure 4: 3D radiation dose map without shielding lead ig- loo in place (top); 3D radiation dose map with the shielding le...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
2
c72a5bb7-5c93-4bed-b713-b76cdc8cfe2b
Canon klystron, the RF circulator, the first all -copper pho- toinjector cavity, and multiple waveguides and vacuum pumps , are now installed at the facility . The last year was spent to sa tisfy various engineering and radiation safety re- quirements for CARIE operation. The high- power testing of the all- copper ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
2
5e618f47-5420-40cc-9e41-f5b359b59878
[2] M. Zuboraj et al. , “High -gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster”, Phys. Rev. Accel. Beams , vol. 27 , no. 2, p. 021001, Feb. 2024. doi:10.1103/PhysRevAccelBeams.27.021001 [3] J. Upadhyay and K. A. Bishofberger, “Summary of the w ork- shop on UED o ppor...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
2
b2599f25-27f7-4849-a8e3-3014ab83770e
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7314 1556 MC7.T06: Normal Conducting RFTUP7314 TUP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pu...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
2
2307ed1f-7caa-43c9-a999-1793fc845fb4
[5] E. Simakov et al. , “Update on the status of C -band high gra- dient program at LANL”, in Proc. IP AC’23 , Venice, Italy, May 2023, pp. 2057-2060. doi:10.18429/JACoW- IPAC2023- TUPL138 [6] E. I. Simakov et al. , “Status of the CARIE high gradient pho- tocathode test facility at Los Alamos National Laboratory...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
3
22a60c0d-ead3-4539-a633-3627b8588edd
ice, Italy, May 2023, pp. 2061-2063. doi:10.18429/JACoW- IPAC2023- TUPL139 [9] J. A. Kulesza , “MCNP User’s Manual – Code Version 6.3”, Los Alamos National Laboratory , Los Alamos, NM , USA, Rep. LA-UR-22-30006 , 202 2. 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7314.pdf
3
9779e8f1-b07d-493b-ba65-7d031fbfb3a2
PROGRESS ON UPGRADES TO CCL RESONANCE CONTROL AT LANSCE W. Hall†, M. Rodriguez, J. Valladares, J. Vega, Los Alamos National Laboratory, Los Alamos, United States Abstract The resonance control system for the cavity- coupled lin- ear accelerator (CCL) portion of the Los Alamos Neutron Science Center (LANSCE) ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
0
73350873-c07a-47da-9b22-7c3e49e012e8
or its ratio to forward power should be implemented to im- prove issues inherent to the present control system. These relevant data have been collected for several RF modules and analyzed. Additionally, the control of the va lve used to maintain water temperature is antiquated, and a commer-cially available off -the-...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
0
48b7546d-4900-4a92-a66b-1de25a623444
resonance control used for the CCL. The CCL operates at a frequency of 805 MHz with a peak power between 500 and 1200 kW, and with a pulse repetition rate of 120 Hz and a pulse width of about 1ms , there is about 50 to 140 kW average power that must be dissipated in the cooling system. The cooling system is also ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
0
5cf4e81d-3924-40e2-bfbe-c75b708c6d07
flaws that have resulted in beam downtime and extensive labor throughout the life of the CCL. The control system has four temperatures readings of the inlet and outlet going in two directions across the length of the CCL module , and the average of these readings is maintained at a temperature that is set by the meas...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
0
c195e507-febf-472e-ba56-1ad5d6344aff
system is in blue. This process is performed each year, and some of the is- sues that have occurred in the past several years include: bad thermistor contacts, improper RF attenuation due to changes in tuning, and shifts in required temperature or poor initial settings. These issues necessitate an upgrade to th...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
0
a2077c8c-06ca-409b-891b-1fc3e389d0ec
LEGACY SYSTEM MONITORING The FPGA is used to read both pulsed RF signals and DC signals that are output from the original resonance con- trol system. These signals have been used in the past to ___________________________________________ †twh@lanl.gov *Work was performed under the auspices of the US Department...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
0
637631d6-8163-43fb-93c8-42f3b2ce2be4
monitor and troubleshoot systems that are not operating correctly. A history of values is then stored in the real -time application for tracking trends while the system is being actively monitored, and these values can also be written to files for later analysis. Data C ollection The FPGA runs on a 15µs loop to ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
1
bcfef607-91fd-4aa3-ab1d-f177b0e88819
trol system. The four temperature probes are averaged in an analog circuit and output to the front panel, and this out- put voltage is 1V for every degree Fahrenheit above or be- low the nominal 0V at 80°F . An average power detector is also used, and a voltage is output to both the controller and the front panel. Th...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
1
299d9e6d-ae28-49e6-8d23-505dc8034240
control. Data was collected with repetition rates of 10 Hz and 60 Hz, and the temperature during control with RF had a range of about 1.2°F at 10 Hz and about 0.3°F at 60 Hz. The higher repetition rate will heat the water, which makes changes to the chilled water flow into the mix tank more responsive, explaining ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
1
71295f4d-cecc-48e3-9b2e-5234047ede68
sponse, so a timer was added to calculate the motor speed within the FPGA at this rate. The data collected by the Real -Time application at 1 s intervals was then used to determine what control signal would be calculated. The summations used in calculati ons add six blocks of variable numbers of data points , so ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
1
27c4590c-53aa-44aa-b33b-69b30a01024f
in the oscillations of temperature and return loss. This might indicate that a delay on the temperature is needed for control, but the control calculations also have a natural delay that might be sufficient. This data also shows the behavior that was expected with return loss minimized at some temperature (81.1...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
1
edfb2abf-144e-4867-b058-a839a27a290a
modern equipment that can be controlled by digital cRIO outputs. The output of the cRIO is controlled by one of sev- eral methods. A manual output was first used to test the chain from the cRIO to the stepper driver and ultimately the stepper motor valve assembly. This was first tested on the bench then at severa...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
1
ebb1292c-55f4-40a1-bedb-6cc59a01a068
totype also works well with 2 microsteps at half the speed. The next step was to see if the cRIO could maintain a fixed temperature. The temperature should remain at a con- stant level when there is no RF, and with RF relatively con- stant, there should also be little variation in temperature, so maintaining a t...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
1
f63d1131-1e42-4ce4-a1a6-d66f3b9f55cd
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7315 MC7.T06: Normal Conducting RF 1559TUP: Poster session TUP7315 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pu...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
1
858084ec-839c-41de-9cfd-76539016661c
summations of the sample number 𝑛𝑛𝑖𝑖 and the temperature 𝑇𝑇𝑛𝑛 over 𝑁𝑁 samples to get 𝑑𝑑𝑑𝑑 𝑑𝑑𝑛𝑛=𝑁𝑁∑𝑛𝑛𝑑𝑑𝑛𝑛 𝑁𝑁−1𝑛𝑛=0−∑𝑛𝑛𝑁𝑁−1𝑛𝑛=0 ∑𝑑𝑑𝑛𝑛 𝑁𝑁−1𝑛𝑛=0 𝑁𝑁∑𝑛𝑛2𝑁𝑁−1𝑛𝑛=0−�∑𝑛𝑛𝑁𝑁−1𝑛𝑛=0 �2 (1) This method was implemented with some success, but there was substantial noise...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
2
acbe4e1c-09a6-4285-91e2-e583e14af8ab
tem. Several gains used to control the system to 86°F are shown in Fig. 4 . The proportional and derivative gains (Kp and K d respectively) of 100 and 4000 maintained a temperature range of about 85.95 to 86.15°F, which is sim- ilar to the range of control with RF. The integral gain was always set to zero and i...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
2
58857cd5-6e77-455c-bcf1-8b8814726494
allow for direct control based on RF. The prototype system has a PID loop that can contr ol on phase between the for- ward power and reflected or cavity field signals, but this does require the phase to be set up well . A simple mixer could be used for the phase detection, or a 360° phase de- tector like that propos...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
2
9d7ac3c0-6597-4838-b534-b2427330935e
return loss to be found using N sets of data in an expression analogous to Eq. 1. The use of estimated motor position in place of the temperature is also proposed for investigation. This would eliminate the need for thermistors, which have been temperamental, but it is not clear if this method will be viable. ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
2
6968d0ed-af81-4632-913c-83f23390e2a8
driver could be changed in conjunction with the motor - valve assembly to add a radiation -hardened position meas- urement and a more linear valve. The control with RF will be tested . In addition to adjust- ments for control at start- up and nearly constant RF levels, water temperature should control to a certai...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
2
ad74bba6-74fa-4cd2-b9bc-627def234847
REFERENCES [1] J. M. Potter, “Novel RF Phase Detector for Accelerator Ap- plications”, in Proc. NAP AC'22 , Albuquerque, NM, USA, Aug. 2022, pp. 446-448. doi:10.18429/JACoW- NAPAC2022- TUPA43 [2] A. Scheinker , “Application of Extremum Seeking for Time - Varying Systems to Resonance Control of RF Cavities,” IE...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
2
cdb906b9-1a0f-4cba-bd92-ce283db13b30
[3] R. Leewe, “RF cavity tuning based on reflected power meas- urements”, Ph .D. thesis, School Mechatronic Syst. Eng., Si- mon Fraser University, 2017. 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7315 M...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7315.pdf
3
05589ab3-4d8f-4440-a1b9-04192837d6f5
CAVITY OPTIMIZATIONS AND BEAM DYNAMICS SIMULATIONS FOR LANSCE UPGRADES∗ M. Kaemingk†, P. M. Anisimov, L. Duffy, J. W. Lewellen, K. Shipman, B. Sims, H. Xu Los Alamos National Laboratory, Los Alamos, NM, United States Abstract The Distributed Drive Linear accelerators (DDLs), in whicheachacceleratingcellisindependentlyp...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
0
11087c85-24ae-43de-a98f-46c3f4c59bff
beinginvestigated. Herewereportresultsfromcellprofile optimizationsandbeamdynamicssimulationscarriedout tostudythepotentialadvantagesofaDDLarchitecturein the LANSCE accelerator. INTRODUCTION The Los Alamos NeutronScience Center (LANSCE) ac- celerator complex supports a wide variety of applications. Theseincludeapplicat...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
0
fd69b9a7-f969-4cb9-8a40-1c9fbef5146c
well as some preliminary beam dynamics simulations. CELL PROFILE OPTIMIZATION The desired resonant frequency of the cell is 𝑓0= 805MHz. The cell length is 8.0274cm and the bore radius is1.5875cm , matching the cell design described in Ref. [ 1]. ThiscelldesignisusedintheCCLModule5Tank1(M5T1) in LANSCE. The cell was as...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
0
6eaa746a-1b03-421f-b2ef-f5e02e6fc802
∗Work supported by U. S. Department of Energy through the Laboratory DirectedResearchandDevelopmentprogramofLosAlamosNational Laboratory,under project number 20260114ER. †kaemingk@lanl.govpower, and 𝑉acc= ∫𝐿/2 −𝐿/2𝐸𝑧(𝑧)cos(2𝜋𝑓0𝑧 𝛽𝑐)𝑑𝑧.𝐸𝑧is the on-axis longitudinal electric field, 𝐿is the cavity length, ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
0
d57c3d3b-6728-497f-b098-0c0948d309a2
these parameters are given by 𝑧𝑖= 𝑢𝑖𝑍, 𝑟𝑖= 𝑣𝑖(𝑅−𝑟)+𝑟, 𝑠𝑖= 𝑡𝑖𝑅/𝑍, with𝑅,𝑟,𝑍defined as shown in Fig. 1and the set of param- eters𝑢𝑖,𝑣𝑖,𝑡𝑖beingtheoptimizationvariables. Theranges of optimization variables are shown in Table 1. Figure 1: Reference figure for cell optimization parameters. 𝑅wasall...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
0
cbe8ad3c-bfc7-4b29-ae8c-3eda54d98dbd
Table 1: Cell Profile Parametersand Optimization Ranges Point 𝑢 𝑣 𝑡 1 0 1 0 2 1 − 0.7 1 0 3 1 0.4 − 0.9 -∞ 4 1 0.2 −0.5 -∞ 5 0.7 − 1 0.1 − 0.3 0 − 5 6 0.5−0.95 0.05 − 0.3 ∞ 7 0.6 − 1.1 0 0 8 𝐿/2𝑍 0 0 Figure 2: Pareto front showing the trade-off between 𝐸peak/𝐸accand𝑅s(𝛽)/𝐿inthesetofoptimizedcellprofiles. Give...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
1
0b4d9969-1fd7-4568-8974-ef9f8da4fd7d
this𝑅s(𝛽)/𝐿along with its electric field magnitude. Table2compares some of the cell parameters to the cor- responding ones of the M5T1 CCL cell reported in Ref. [ 1]. Werefertothecelloptimized inthisworkasthe DDLcell. Weseethatforasimilar 𝑅s(𝛽)/𝐿,𝐸peak/𝐸acchasbeensig- nificantlyreducedbyafactorof ≈ 46%,whichind...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
1
f988dc2a-70b7-44e3-8c17-0b4a30cd9ca4
themaximumallowedacceleratinggradientintheoptimized cellcanbeafactoroftwohigherthanachievableinaM5T1 CCL cell. PARTICLE TRACKING SIMULATIONS Wenowdiscusspreliminaryresultsobtainedfromparti- cle tracking simulations performed with the general particle tracer (GPT) code [ 5] tracking 10000macro-particles. The purpose of ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
1
b19fc87f-4f8e-4116-8cf5-925a85b3e57b
malized RMS beam emittances 𝜖𝑛,𝑥and𝜖𝑛,𝑦along with the beam energy spread and temporal length were obtained from simulations for LAMP reported in [ 6,7]. The beam size and transverse phase space correlations were optimized to minimize the beam size variation along the DDL. This was done by optimizing the radius an...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
1
6b0e4ad6-db63-4642-ab91-dd7654931593
𝑥and𝑦along the DDL. As stated earlier, the beam radius and𝛼𝑥,𝛼𝑦were optimized to minimize the variation in the beam size along the DDL. Specifically, theywereoptimized to minimize √Var(𝜎𝑥𝑦), where𝜎𝑥𝑦=√𝜎𝑥𝜎𝑦and𝜎𝑥,𝜎𝑦17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
1
b97b3153-c288-42e6-8be4-6ad306985285
Table 3: Beam parameters used in the particle tracking sim- ulations. Parameter Value Unit Bunch charge 128 pC RMS temporal length 38 ps Kinetic energy 100 MeV RMS energy spread 0.256 MeV 𝜖𝑛,𝑥 1.17 µm 𝜖𝑛,𝑦 0.91 µm Beam radius 5 mm 𝛼𝑥 0.55 - 𝛼𝑦 0.53 - Figure4: On-axiselectricfield and beamkinetic energyin DDL....
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
2
9c1671ef-93c2-4033-a771-1217cda3d4b6
Figure 6: TransverseRMS beam sizes along the DDL. CONCLUSION WeoptimizedthecellprofileforaDistributedDriveLinac (DDL)beingdesignedtoreplacethecurrentCoupled-Cavity Linac (CCL) in the Los Alamos Neutron Science Center (LANSCE)acceleratorcomplex. Thecellprofilewasopti- mizedtomaximizethetime-dependentshuntimpedanceand mi...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
2
82978b50-a12c-41b0-9c2b-15e5c8322d48
tance growth could be limited to less than 1mmand5% respectively. REFERENCES [1]S.Kurennoyand Y.Batygin,“Electromagneticandbeamdy- namicsmodelingoftheLANSCEcoupled-cavitylinacwith CST studio”, in Proc. IPAC’23 , Venice, Italy, May 2023, pp. 2209–2211. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt423-TUPM/zero.alt4/zero.al...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
2
2f1a6b56-26f0-488f-a025-f26c599fa5d8
studio-suite/ [5]S. B. van der Geer and M. J. de Loos, “Applications of the general particle tracer code”, in Proc. PAC’97 , Vancouver, B.C., Canada, May1997, paper 8P090, pp. 2577–2579. [6]J. W. Lewellen et al., “LANSCE accelerator modernization project conceptual design report”, Los Alamos National Labo- ratory,LosAl...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
2
98db6835-1c39-4773-a2e6-ffe3165947b0
[7]E.-C.HuangandJ.Upaydhyay,“PreliminarylookattheLBEG & MPEG beam transmissions between HPSim and operationdata”, Los Alamos National Laboratory, Los Alamos, NM, USA,Rep.LA-UR-25-24103, Jan. 2025.17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-53...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7317.pdf
3
8a901537-7bb8-4efe-8483-5e9e3818bbe4
CERAMIC ENHANCED ACCELERATING STRUCTURE (CEAS) OPTIMIZATION FOR IMPROVED SHUNT IMPEDANCE∗ B. Sims†, H. Xu, J. W. Lewellen, L. Duffy Los Alamos National Laboratory, Los Alamos, United States Abstract We present a COMSOL Multiphysics®–based workflow, using the Optimization Module, to increase RF cavity shunt impedance(𝑅...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
0
1587e54f-f436-4b34-9f6e-f93e91171a71
coneangle,gap,fillets). Thisoptimizationmaximizes 𝑅𝑠ℎ subjecttofrequencylockingandengineeringlimitsbased on the cavity geometry. Eigen-frequency studies are used as the primary optimization tool producing a field map of the desired TM020 mode as well as the power dissipated on thewallsandwithintheceramicmaterial. Pos...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
0
aae5906f-b821-45ef-b137-2edeec726356
to the beam axis [1–3]. CEAS Cavities operate in a TM020 mode, creating a TM010-like field pattern in the paraxial region. In a typical metallic TM010 cavity, RF currents in the metal are the dominant cause of ohmic losses. This is alleviated in a CEAS cavity as the ceramic insert is an insulator which leads to minimiz...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
0
669c2db5-ecf6-4ecb-9765-815015d72887
∗WorksupportedbyU.S.DepartmentofEnergythroughtheLaboratory DirectedResearchandDevelopmentprogramofLosAlamosNational Laboratory, under project numbers 20210083ER and 20240136ER. †sims@lanl.govpower control. In Fig. 1, the CEAS cavity length ( 𝐿cav= 40.27 mm )isnotsetbyaconstantphaseadvance; instead, it is chosen to max...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
0
6d7d607c-57f3-4fa7-af14-3ccda97d0ad2
COMSOLsimulationsusedTrans-TechD3500ceramic. The design also uses the nose cone gap to beta match the transit time of an ultra-relativistic beam. Table 1: Trans-Tech D3500 Material Properties Material𝜀 𝑟𝑡𝑎𝑛(𝛿) D3500 35.5 1.06×10−4 Figure 1: Optimizer parameters, black indicate fixed param- eters, red indicates pa...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
0
9da7b384-dc19-4b38-bcf5-23f6a15a1149
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7318 1566 MC7.T06: Normal Conducting RFTUP7318 TUP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pu...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
0
1f0c7dce-6374-4338-bdc1-51f46a23a7e0
maximizetheshuntimpedanceofthecavitywhilealsoensur- ing that the peak field in the cavity is reasonably minimized to mitigate risk of arcing. Specifically, the ratio between accelerating gradient and peak E-field was integrated in the FOM,asthisisacommonmetricwhendesigningcavities with strong reentrant designs that cou...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
1
c6afdcd2-c4f2-4b86-b524-a97f84d2364d
Figure2: Cavityelectricfieldmagnitudedistributions,(a) TM020 CEAS, (b) TM010 fully metallic. Table 2: Comparing CEAS and metallic cavity results CEAS Metallic TM020 TM010 Resonant freq. [GHz] 5.098 5.098 Q factor 18744.8 14580 Shunt imp. [MΩ] 0.9359 2.497 Ceramic Thickness and Shunt Impedance Duringoptimizationwesawast...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
1
3c71e20a-7d32-4466-a552-7b6f4146b989
the TM010 cavity. Previous experiments done at LANL haveshownthat2mmceramictubesarepracticalandcanbe used reliably. These results indicate that precisely ma- chinecustomthicknessceramicsshouldbetestedforfurther improvements. Figure 3: Shunt Impedance vs Ceramic Thickness. CONCLUSION CEASCavitiesareapromisingapproachtoc...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
1
2beb16f8-e102-47b3-9edb-93ea06bab393
viability of designing and fabricating such precise inserts. REFERENCES [1]H.Xuet al.,“High-efficiencytraveling-waveacceleratingstruc- ture with ceramic insertion”, inProc. IPAC’24, Nashville, TN, USA, May 2024, pp. 482–484. doi:10.18429/JACoW-IPAC2024-MOPR13 [2]J. Upadhyayet al., “Design of a ceramic enhanced normal c...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
1
04cb82a2-dc9f-4053-85cc-ffb9e41c3c97
mento, CA, USA, Aug. 2025, pp. 799–801. doi:10.18429/JACoW-NAPAC2025-WEP060 [5]Y. K. Batygin, “Beam dynamics in independent phased cavities”,Nucl. Instrum. Methods Phys. Res. A, vol. 1040, p. 167192, Oct. 2022. doi:10.1016/j.nima.2022.167192 [6]COMSOL Multiphysics v. 6.4,COMSOLAB,Stockholm,Swe- den, 2025.https://www.co...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7318.pdf
1
09a45741-0421-4338-bcab-bceadf8b7805
DESIGN AND TEST OF AN 𝑋-BAND CAVITY FOR SHORT-PULSE RF BREAKDOWN STUDIES G. Rijal∗, M. Shapiro, X. Lu† Northern Illinois University, DeKalb, IL 60115, United States G. Chen, S. Doran, J. Hlavenka, W. Liu, R. Margraf-O’Neal, A. Ody, P. Piot, J. Power, E. Wisniewski Argonne National Laboratory, Lemont, IL 60439, United ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
0
43442756-1eaa-43a4-a18f-687202d94f37
drivenelectrongrowthandreducefield-emission-induced Jouleheatingoncavitysurfaces. However,systematicexper- imental investigations of these effects remain limited. We present the design of a dedicated experiment using a single- cell high-gradient 𝑋-band cavity to be tested at the Argonne Wakefield Accelerator (AWA) for...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
0
2e32b681-7e90-4dac-afac-6cf1f75212da
limitedbyRFbreakdown,whichremainsacriticalconstraint in the development of compact accelerators. Breakdown processesare governedbya combination offield emission, multipacting,surfaceheating,andplasmaformation,among otherphenomena. Theironsetdependsonthecomplexin- terplayof multiple factors,including local field conditi...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
0
1f7ef400-f768-4c5c-ad56-cd385b5afaa2
multi-bunch train [ 5]. In this regime, the RF pulse duration becomes comparable to or shorter than the characteristic de- velopment time of breakdown-related processes, potentially ∗grijal1@niu.edu †Alsoat ArgonneNationalLaboratory,Lemont, IL 60439, United Statessuppressingelectronmultiplicationandlimitingsurfaceheat-...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
0
692a24ca-54cf-4704-83ae-0098eb349a67
alsoinfluencedarkcurrentemissionandbreakdownonset. Here,wepresentthedesignandplannedexperimentalstudy of a single-cell 𝑋-band cavity at 11.7 GHz, fabricated in two configurations: a mechanically clamped structure and a brazedstructure. Bothconfigurationssharethesameelec- tromagneticdesign. ThisenablesadetailstudyofRFp...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
0
d7b81fb2-a74d-4abb-9040-5ebfacd8580f
WR 90 Port(a) (b) Figure 1: Geometry of the single-cell 𝑋-band cavity operat- ingat11.7GHz. (a)Vacuummodelofthecavitywiththe WR90 waveguide coupler. (b) Normalized 𝐸𝑧field distribu- tion on the cavity midplane.17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-25...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
0
569a46c0-00e7-4016-bacd-0e78755bfa2a
RF Input Port IRF Output Port II (a) (b) (c) Matching WaveguideFigure2: Single-cell 𝑋-bandcavitydesignanditsshort-pulseRFresponse. (a)Normalized 𝐸𝑧fieldcontourplotonthe cavity midplane. (b) Simulated 𝑆11and𝑆21responses of the cavity. (c) Time-domain evolution of the accelerating gradient (red) and the input R...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
1
c4c11410-abb5-4860-a2b7-6b972233fc3b
to breakdown initiation and surface stress [ 1,2]. The nor- malized𝐸𝑧fielddistributionoftheoperatingmodeonthe cavitymidplaneisshowninFig. 1(b). Thecorresponding normalized 𝐸𝑧fieldcontourplotisshowninFig. 2(a),while the simulated 𝑆11and𝑆21responses in Fig. 2(b) confirm operationnearthetargetfrequencyof11.7 GHzandv...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
1
f3637afa-5157-409b-a32b-dc51561d775b
withinthepulse-lengthrangerelevanttotheplannedhigh- power experiment. Two cavities sharing the same electromagnetic design have been fabricated for the experimental campaign. In one configuration,thecavityhalvesaremechanicallyjoinedto formaclampedstructure,introducingaphysicalinterfaceat themidplane. Intheother,thetwoh...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
1
bc896142-7b25-438f-a107-bc4d30385774
DIAGNOSTICS The experimental study will be carried out at AWA using nanosecond-long RF pulses generated by the 𝑋-band power- extractionsystemdevelopedforhigh-fieldshort-pulseopera- tion [3,5]. Figure3shows the clamped cavity configuration usedfortheinitialinstallationandtesting,whileFig. 4shows theplanned vacuumassemb...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
1
2d018087-63d1-467e-8b0c-ced332a4565c
emitteddarkcurrent,providingdirectinformationonfield emission and possible electron multipacting. This diagnostic layout is designed to correlate RF and dark-currentmeasurementsduringhigh-gradientoperation. Earlierstudieshaveshownthattime-resolvedRFanddark- current signals are key observables for understanding break- F...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
1
c997f9f2-85d8-42ad-b749-410d1cf911f6
Transmitted rf pulse Vacuum chamber Faraday cup RF probeDC1 DC 2 Input rf pulseReflected rf pulseFigure4: Experimentalsetup forshort-pulse RF breakdown studiesinthesingle-cell 𝑋-bandcavity. The3DCADmodel shows the vacuum assembly of the cavitytogetherwith the maindiagnostics,includingthedirectionalcouplers(DC1 an...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
2
8a8b1781-ed10-4bf2-aa70-7cab39044b1d
design, we fabricated a structure prototype using additive manufacturing. preliminary low-power measurements were performed on a3D-printed prototype havingthe same cav- ity geometry as the present cavity. The prototype, shown in Fig.5(a), was fabricated by direct metal laser sintering (DMLS) using AlSi10Mg aluminum all...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
2
78c5abae-7c9a-42bd-82fc-2c4b93872ee8
CONCLUSION AND OUTLOOK A single-cell 𝑋-band cavity operating at 11.7 GHz has been designed for systematic studies of RF breakdown and dark current under nanosecond-scale short-pulse excitation. Theelectromagneticdesign,simulatedRFresponse,andpre- 3D printed structure (a)Figure5: Preliminarylow-powermicrowavemeasure...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
2
4ffd07e6-8279-4b29-b25f-10a971d1a9d4
on breakdownscaling laws and electron multiplication pro- cesses,ultimatelyinforming thedesign ofnext-generation, high-gradient compact accelerators. ACKNOWLEDGMENTS ThisresearchwassupportedbytheU.S.Departmentof Energy, Office of Science, Office of High Energy Physics under Award DE-SC0021928. REFERENCES [1]A. Grudiev,...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
2
5d5d2384-8ff9-43e3-86ad-a1daefd6a771
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7319 1570 MC7.T06: Normal Conducting RFTUP7319 TUP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pu...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
2
35b4cfdc-fff5-4970-b5ee-88bbbd4ab22c
[2]E.I.Simakov,V.A.Dolgashev,andS.G.Tantawi,“Advances inhighgradientnormalconductingacceleratorstructures”, Nucl. Instrum. Methods Phys. Res. A , vol. 907, pp. 221–230, 2018. doi:1/zero.alt4.1/zero.alt416/j.nima.2/zero.alt418./zero.alt42./zero.alt485 [3]W.H. Tan etal.,“Demonstrationof sub-GV/maccelerating fieldinaphoto...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
3
6b5d9385-517c-4bb8-9c49-edbd6c64b4ea
[5]M.Pengetal.,“GenerationofhighpowershortRFpulsesus- inganX-bandmetallicpowerextractordrivenbyhighcharge multi-bunch train”, in Proc. IPAC’19 , Melbourne, Australia, May 2019, pp. 734–737, 2019. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt419-MOPRB/zero.alt469 [6]S. Weatherly et al., “Standing wave dielectric disk accel...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
3
e7432d2a-3448-4b37-8c60-91649f06902f
studies of dark current in radiofrequency structures for short- pulsehigh-gradientacceleration”, Phys.Rev.Accel.Beams , vol.28, p. 111301, 2025. doi:1/zero.alt4.11/zero.alt43/w9mh-3klh [9]G. Rijal, M. Shapiro, X. Lu, S. Doran, and J. Power, “RF breakdownanddarkcurrentstudiesinshort-pulseaccelera- tion”,inProc.NAPAC’25 ...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
3
194a14ba-b1fa-4dd0-979b-34416671e9c9
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7319 MC7.T06: Normal Conducting RF 1571TUP: Poster session TUP7319 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, pu...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7319.pdf
3
9fc4cab7-345f-447e-b44a-e42dfd5c1a5d
A NOVEL APPROACH TO RF POWER COUPLING IN RADIO -FREQUENCY QUADRUPOLE ( RFQ) S TRUCTURES: BUILT- IN COAXIAL DOUBLE -LOOP CO UPLING PO RT* Sung- Woo Lee†, Haitao R en, George Toby, Timot hy M iner, J ohn Moss, Charles Peters, San g-ho Kim, Yoon W. Kang Oak Ridge National Laboratory (ORNL), Oak Ridge, TN, USA Ab...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7320.pdf
0
9805f4dd-905b-4877-821b-51fad7547b6f
novel RFQ power coupling concept: a single -input coaxial center -fed double -loop antenna built directly into the vane structure of an RFQ. The design integrates back -to-back loops into the RFQ vanes, fed by a TEM coaxial transmis- sion line with a standard 50- Ω characteristic impedance. The configuration enable...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7320.pdf
0
140e7247-ae69-434d-aefb-04ae221d76e8
ing vacuum integrity and field symmetry. Waveguide iris couplers accommodate high average power but have fixed geometry that limits retuning. Coaxial loop couplers pro-vide tunability but require a tapere d coaxial transition when the port area is small, constraining power handling and thermal performance. Loop coup...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7320.pdf
0
97aa461a-7697-4b13-a029-0ff5812f2f17
maintenance [2]. This paper proposes the coaxial double - loop coupler built- in to the cavity structure to address these issue s. The design integrates the coupler directly into the RFQ vane body, enabling a larger coaxial conductor cross -section, direct thermal coupling to the RFQ cooling infra- structure, and imp...
D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7320.pdf
0