e410e22b-5a0d-4cad-8cde-c51bffae7bf7 | about both vertical and horizontal axes, consistent with
the magnet geometry and boundary conditions. The
maximum deformation is approximately −3 µm at the core
contact interfaces and −1.5 µm at the pole profile, remaining well within tolerance limits and indicating
sufficient me chanical rigidity to suppress unwan... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 1 |
2cd15d35-5538-4ade-9010-b0ad476257ef | systematic errors, with angular devia tions limited to below
7 mrad in pitch and yaw, and within 35 mrad in roll
"as
shown in Fig. 4.
Figure 4: Installation and alignment of quadruple pole
magnets type A and B .
The QD2 quadrupole magnet was operated at its
nominal current of 100 A, and field deviation... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 1 |
feaff361-38be-4804-acf7-846286cd1f36 | quadrupole magnet using a stretched wire system reveal
significant multipole field errors, including both normal
and skew components. The acceptance criterion was
defined as normalized multipole errors not exceeding 5×10⁻ 4 for all orders, excluding the second order term
corresponding to the main quadrupole field. ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 1 |
2959b389-0808-4697-8bbe-6d8f42943ce0 | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7655
1708 MC7.T38: Mechanical designTUP7655 TUP: Poster session
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publi... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 1 |
1403b67c-61a1-4aa0-bc52-6de22a06b0b3 | Figure 6: Normal multipole and Skew multipole of
quadruple pole magnets type B .
Magnetic field measurements in Fig. 6 of the QD2
Type‑B quadrupole magnet show that only a few normal
multipole components, specifically orders 5 and 13,
exceed the acceptance criteria, while all skew multipole
components remain... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 2 |
88004dc6-6650-4130-928c-7c60cf7447d9 | symmetry, elimination of pole disassembly and
reassembly, and improved pole positioning accuracy
effectively mitigate rotational asymmetry and assembly
related errors. Although a small number of higher order
normal multipole components remai n above tolerance,
their impact on beam dynamics is limited, confirming... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 2 |
b82e1c58-185f-4f69-8320-058b349bc802 | excitation to near the maximum specified current, in order to evaluate the consistency of the magnetic model under
various operating regimes. The comparison results show
that the magnetic flux density trends predicted by the sim-ulation are in good agreement with the experimental meas-
urements throughout the entire ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 2 |
b6728aa7-88a0-43fc-9f23-5eb1fa6c656c | in the SPS‑II storage ring.
CONCLUSION
Compared with the QD2 Type‑A magnet, which
exhibited multiple normal and skew multipole components
exceeding tolerance limits, the Type‑B magnet shows a
clear improvement in magnetic field quality. This
improvement is most notable in the significant reduction
of skew multi... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 2 |
c35c72e4-5b46-4b92-9837-19b31e5c2ff1 | accurate performance prediction and future SPS‑II design
optimization.
REFERENCES
[1] P. Sunwong, P. Klysubun, T. Phimsen, S. Prawanta, and P.
Sudmuang, “Magnet Design for Siam Photon Source II”, in
Proc. IP AC'19 , Melbourne, Australia, May 2019, pp. 4361-
4363. doi:10.18429/JACoW- IPAC2019- FRXXPLM2
[2] Tan... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 2 |
bf4ce2a0-3fc3-42c2-87fc-556105284fa1 | minimize field errors in quadrupole magnets," in IEEE Trans-
actions on Magnetics , vol. 24, no. 2, pp. 1369- 1372, March
1988. doi: 10.1109/20.11494
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7655
... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7655.pdf | 2 |
e5863641-878e-43e2-84d3-6873a27c851c | INFLUENCE OF CURRENT EXCITATION PROFILES ON
SCREENING-CURRENTEFFECTS IN REBCOBENDING MAGNETS FOR
THE HEFEI ADVANCED LIGHT FACILITY
J. Xia∗, Z. Bai, C. Chen, J. Xu, Z. Zhu, J. Zhao
University of Science and Technology of China, Hefei, China
Abstract
ReBCO coated conductors are promising for compact
high-field bending ma... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 0 |
18e4c997-35bd-404d-b072-caaddd4d0a84 | affects screening-current relaxation and the induced-field
distribution. Underthepresentconditions,finalholdingat
theoperatingcurrentismoreeffectivethanaslowfinalramp
or distributed intermediate holding, providing guidance for
optimizing charging schemes for future ReBCO bending
magnets.
INTRODUCTION
ReBCO coated condu... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 0 |
15543bdc-b5bb-43bf-9416-8fe2a81dc739 | during magnet excitation because of the large aspect ratio
of coated conductors [ 2,3]. The resulting screening-current-
induced field (SCIF) can affect the magnetic-field behavior
of the magnet and may lead to excitation-history-dependent
field deviations. This effect needs to be carefully consid-
eredforstorage-ringa... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 0 |
e06c5347-6e83-4374-b533-eafda643ca23 | mizing charging schemes for future HTS bending magnets.
∗waterx09@gmail.comMAGNET CONFIGURATION AND
SIMULATION SETUP
Magnet Configuration and Numerical Model
Figure1showsthetwo-dimensionalcross-sectionalmodel
of the HTS bending magnet, which consists of an iron core,
HTS coil regions, and an air domain. To reduce the c... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 0 |
1beae4c9-6b33-498d-80f8-78cb6089158c | Operating current, 𝐼op A 270
Estimated critical current, 𝐼c A 385
Perpendicular field on conductor, 𝐵⟂T 5
Peak on-axis magnetic field, 𝐵peak T 6
On-axis field integral, ∫𝐵𝑦𝑑𝑧 T⋅m 0.368
TheelectromagneticbehavioroftheHTSmagnetiscal-
culated using the 𝐻-formulation. The governing equation is
written as
∇×(𝜌∇× H... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 0 |
5679cb3a-68b8-44b1-8545-4c402e17963d | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7656
1710 MC7.T10: Superconducting MagnetsTUP7656 TUP: Poster session
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work,... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 0 |
066dbca7-6b01-484f-9260-81c5a213b282 | model. Thermaleffectsareneglectedbyassumingsufficient
temperature margin.
In the two-dimensional model, the total current density
in the HTS region is obtained as
𝐽 =𝜕𝐻𝑦
𝜕𝑥−𝜕𝐻𝑥
𝜕𝑦. (2)
The screening-current density is then evaluated by sub-
tracting the equivalent uniform transport-current density:
𝐽sc= 𝐽 ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 1 |
5df74c9f-9135-47cc-8949-ea568b9bac02 | Thecurrentexcitationprofilesconsideredinthisstudyare
shown in Fig. 2. In all cases, the transport current is kept at
0 A during the first 60 s, and the operating current is 270 A.
Figure 2: Current excitation profiles used in the simulations.
(a)Threeprofileswiththesamepreparationtimeof960s:
uniform ramp, fast ramp wit... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 1 |
33207d87-34b7-40fb-8703-4a54065721a8 | 400-sholdingstage. Thiscomparisonisusedtoexaminethe
influence of holding-time distribution on screening-current
relaxation.
RESULTS AND DISCUSSION
Figure3shows the temporal evolution of the normal-
ized screening-current density. In Fig. 3(a), the fast ramp
produces a large transient screening current, followed by
cont... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 1 |
8b6c70c6-aca8-4a6a-a5df-ad170211cc5f | thanthatobtainedwithfinalholding,suggestingthatholding
attheoperatingcurrentismoreeffectivethandistributing
the holding time during ramping.
Figure3: Temporalevolutionof 𝐽sc/𝐽cBunder different ex-
citation profiles. (a) Uniform ramp, fast ramp with final
holding,andfast-to-slowrampunderthesamepreparation
time of960s.... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 1 |
b60a1191-ed8c-4198-8a78-ab1f8407af15 | Figure4: Spatialdistributionof 𝐵SCIFalongthelongitudinal
direction. (a) Three 960sexcitationprofilesat 𝑡 = 2000 s.
(b)Finalholdingandstepwiseintermediateholdingat 𝑡 =
5000s.
Figure4shows the corresponding spatial distributions
of𝐵SCIF. The three profiles in Fig. 4(a) produce similar
distributions,withdifferencesmai... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 2 |
40a5546e-7feb-48ab-b39f-09bdfd5888df | distributionforthe 0.3A/sexcitationprofile. From 𝑡 = 960s
to𝑡 = 5000 s,thescreeningcurrentdecreasesbutremains
non-uniform,illustratingitsgradualrelaxationintheReBCO
conductor.
Overall, the results show that the screening-current be-
havior depends strongly on the charging history. Under the
presentconditions, finalho... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 2 |
c9e6bb6a-9a6a-49ee-b73e-6f52a06598c4 | currentdependsstronglyontheexcitationprofile. Aholding
stage at the operating current promotes screening-current
relaxation, whereas a slow final ramp or distributed inter-
mediate holding stages do not show a clear advantage under
the present conditions. These findings provide guidance
for optimizing charging schemes ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 2 |
b76a20f0-5bb8-4bff-8ca6-1da5a14985d4 | p. 171044, 2026. doi:1/zero.alt4.1/zero.alt416/j.nima.2/zero.alt425.171/zero.alt444
[2]K.L.Kim etal.,“Studyoneliminationofscreening-current-
inducedfieldinpancake-typenon-insulatedhtscoil”, Super-
cond. Sci. Technol. , vol. 29, no. 3, p. 035009, Feb. 2016.
doi:1/zero.alt4.1/zero.alt488//zero.alt4953-2/zero.alt448/29/3/... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 2 |
cf134dcf-178b-4060-9fea-3dc0ce3bc9c3 | doi:1/zero.alt4.1/zero.alt488//zero.alt4953-2/zero.alt448/27/4//zero.alt444/zero.alt425
[5]J.Parketal.,“Estimationofscreeningcurrentinducedfield
onshortperiodplanarhtsundulator”, IEEETrans.Appl.Su-
percond., 2023. doi:1/zero.alt4.11/zero.alt49/tasc.2/zero.alt423.326261617th International Particle Accelerator Conference... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7656.pdf | 2 |
df721ace-1aae-405f-a41f-5a8593205a3f | DESIGN AND CONSTRUCTION OF THE TWIN -APERTURE
SUPERCONDUCTING QUADRUPOLE FULL -SIZE PROTOTYPE FOR THE
STCF IRSM *
W. Ma †,1, S. W ei2, L. G ao2, M. L iu1, J. Zhang3, Y. Zhu3, X. Wu1, J. T ang†,4
1High Magnetic Field Laboratory, Chinese Academy of Sciences , Hefei, China
2Institute of Plasma Physics, Chinese Academ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 0 |
1040526d-5b7a-45f7-a14d-d0d61b414eeb | ing quench and exhibit good field quality. In this paper , de-
tails of QD1 design, construction and test are reported.
INTRODUCTION
The super tau -charm facility (STCF) is a symmetric,
third -generation electron -positron collider under design
which is proposed by the University of Science and Tech-
nology of ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 0 |
add18481-4452-4cfb-899d-eef1096bdbb8 | nical challenging systems for the STCF accelerator, there-
fore, it is decided that the first stage of key technology R&D activity is to prototype a full-size QD1 coil, as the
QD1 has the highest field gradient and is closest to the IP
(thus , it has the least allowable design space).
IRSM QD1 MAGNET DESIGN
IRS... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 0 |
12f51657-66d8-4bd2-9e56-366a0d40dbb4 | 60 mrad (2θ). Orbit corrector coils, such as a1, b1, a2, a3,
b4, etc., are required to compensate for field errors and im-prove beam optics dynamics. The whole IRSMs are operated inside the solenoid field of the detector magnet with a central field of 1.0 Tesla [2].
Figure 1: IRSM schematic layout (QD1RP - QD1 quad... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 0 |
787afb94-a222-428d-b4c0-5afb1ffa96bd | distance mm 900 1800 na
The key parameters of QD1 and QF2 are listed in
Table 1 . The beam pipe is de signed to be room temperature
and as a component of the cryostat. The beam pipe has a n
inner diameter of 30 mm and 50 mm for QD1 and QF2, respectively. Given the L* of 900 mm and beam crossing angle of 60 mr... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 0 |
0207d341-e833-48ea-89e0-98d425eb6a0b | ___________________________________________
* Work supported in part by the National Key Research and Development
Program of China (Grant No. 2023YFA1607302 ), in part by the National
Natural Science Foundation of China ( Grant No. 12341501). We thank
the Hefei Comprehensive National Science Center for their str... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 0 |
49757613-4a76-4439-91ef-d137a4cefab6 | termination box. It has two formers, has inner radius of 20
mm and outer radius of 26.8 mm. The winding uses canting
angle of 60 °, and in total 80 turns, at 602 A operating cur-
rent, it can produce 50 T/m field gradient over 400 mm
magnetic length. The coil itself has physical length of 460
mm. The maximum field... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 1 |
b7d9601c-f284-48dd-b1ef-3720a5f8894c | Groove size mm 1.9*1.9
Coil inner radius mm 20.0
Coil outer radius mm 26.8
Magnetic length mm 400
Physical length mm 460
Twin -aperture QD1 quadrupole is distributed side -by-
side at angle of 60 mrad and 0.9 m away from the interac-tion point. It is common to have cross -talk issue s which
will introduce... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 1 |
1af32b42-9ae7-4f0e-9345-35b408d46c4c | in Table 1 .
Figure 3: Normal h armonics of the e+ beam at 10 mm refe-
rence radius after local edge correction .
QD1 PROTOTYPE
In the R&D stage, a full size twin -aperture QD1 quadru-
poles prototype has been proposed to study and master key
technologies, such as CNC machining and deformation control of delica... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 1 |
acd8bda9-2853-41f9-91af-8bcf1d1b2a8f | aluminum CNC machined former . After winding the twin
aperture coils and assembled them onto baseplate, the as-
sembly was vacuum impregnated with paraf fin wax. After
impregnation, the coils were de- tooled, jointed and te rmi-
nated . Figure 5 (b) shows the finished QD1 prototype coil
with its joint cups and quenc... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 1 |
5ef55c84-a119-489d-b364-8463595363f4 | the assembled test coil before loading into bucket dewar.
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7657
1714 MC7.T10: Superconducting MagnetsTUP7657 TUP: Poster session
Content from this work may be us... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 1 |
52b9cfaa-b18b-410f-b33c-7a630647cec6 | The rotating coil has effective measurement length of 800
mm to integral cover the coil field profile.
The dewar is filled with helium and directly cooled to
4.2 K, no liquid nitrogen pre -cooling process was used, as
the prototype coil has very limited cold weight. Figure 7
shows the coil top and bottom temperat... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 2 |
1f8c59c1-c83e-4b97-a73d-2419d31f2a35 | No training is observed during the test. Magnet was suc-cessfully ramped to 610A without training quench at slow
ramp rate; another 610A ramping was performed shortly .
After running down to zero, t he magnet ramped to 650A
afterwards at fast ramp rate. Figure 8 shows QD1 prototype
coil’s current and power suppl... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 2 |
ffee7d92-976b-4249-a9b9-31cadb7cad55 | Figure 9 shows the QD1 coil high order normal and skew
harmonics at 605 A operating current. The magnitude of
undesired high-order harmonics are all below 10 units,
which has 3.77 units and 3.06 units of b3 and a3, - 6.53 units
and 6.66 units of b4 and a4. It has negligible harmonics
higher than 5
th order . Al... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 2 |
3d082d18-3117-413e-9cc2-8ae4b98065b7 | wax is designed, built and tested. The magnet exhibits no
training behavior and reaches 50A more than its design cur-
rent. The field quality is excellent. Full scale IRSM system
will be prototyped in the next R&D stage.
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 2 |
fb4ab972-3688-45b3-8b2c-2aa9d39f1104 | REFERENCES
[1] Ai, XC., An, LP., An, SZ. et al. , “Conceptual design report
of the Super Tau -Charm Facility: the accelerator ”, Nucl. S
ci. Tech., vol. 36, no. 242, 2025.
doi:10.1007/s41365- 025-01833-x
[2] W. MA, et al. , "Development of Interaction Region Super
conducting Magnet Twin-Aperture Final Focus Qua... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 3 |
5e4acb4f-dcbf-4dcd-993e-c29b3ee94e02 | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7657
1716 MC7.T10: Superconducting MagnetsTUP7657 TUP: Poster session
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work,... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7657.pdf | 3 |
ce43f954-03d4-4553-98c4-b5c79d579942 | CHARACTERIZATION OF WET -WOUND INSULATED
2G-HTS TAPE IN A DEWAR *
J. C. Jan†, C. C. Tsai, F. Y . Lin, C. K. Yang and T. Y . Chung
National Synchrotron Radiation Research Center, Hsinchu, Taiwan.
Abstract
The second -generation high- temperature superconduc-
tor is under consideration for accelerator applicatio... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 0 |
784e5568-303f-4094-8920-a855a7382ac2 | perimentally investigated. A simple liquid -helium -free test
dewar is also presented.
INTRODUCTION
Second -generation high-temperature superconducting
tape (2G -HTS tape) is a promising option for winding ac-
celerator magnets, offering high current density and excel-
lent performance under strong magnetic fiel... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 0 |
a82c8893-79a2-4b0b-bc60-6f1c7129c0ec | ied to understand HTS behavior after winding. NI winding
suffers from charging delays and shielding current effects; however, its excellent thermal stability enables self -protec-
tion during a quench [1, 2]. MI winding has disadvantages
including low packing factor, charging delay, contact re-
sistance instability, ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 0 |
5ef2f360-d8eb-4435-9348-9ab373d14699 | generate a 3.5 T magnetic field using 12 mm 2G -HTS tape
operating at 20 K in a cryogen -free dewar [4]. Considering
the relatively low magnetic field requirement and operat-
ing current, the insulated (INS) winding method was se-
lected to fabricate a prototype, referred to as HTS -P1-5t. In this study, insulated 2G... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 0 |
5279c217-1652-48d8-bc49-7feb996252cb | lap. The final average width and thickness of the insulated
2G-HTS tape are 12.04 mm and 0.169 mm, respectively.
Figure 1(a) shows the HTS -P1-5t and the return yoke,
with a magnified view of the joint (red box) presented in Fig. 1 (b). The pole and return yoke are fabricated from
DT4E pure iron, and a 1 mm thick ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 0 |
c337b46f-94f0-4b9d-a460-939a191db0bd | HTS tape was wet -wound onto the Cu -spacer. The 2G-HTS
tape layers were bonded together using a cryogenic epoxy
prepared from GY285 and HY5922. The tension applied
during 2G-HTS winding is approximately 2 kgf. In addi-
tion, each 2G -HTS extended lead is overlapped with three
2G-HTS tap es to improve mechanical ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 0 |
618039a2-3d4d-412a-a7c5-da09151f8fee | DT4E, copper, polyimide film, Hastelloy and cryogenic
epoxy. Figure 2 illustrates the material contact arrangement and corresponding thickness within the HTS -P1-5t wind-
ing. Table 1 lists the integrated thermal contraction (
∆L/L)
of these materials [5 -8]. The thermal contraction of the
Hastelloy was approximated... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 0 |
3a9af4ac-ae37-470f-9409-55aea0186140 | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7661
MC7.T10: Superconducting Magnets 1717TUP: Poster session TUP7661
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work,... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 0 |
70fb62fa-bc9d-4a74-97de-e369693fcc02 | Figure 1: Photographs of (a) HTS -P1-5t prototype , (b) a
magnified view of the joint, and (c) the cooling housing.
Figure 2: Material contact arrangement and thickness in the
HTS -P1-5t winding.
Table 1: Integrated Thermal Contraction of Materials
∆L/L
(x10-3) 300-200
(K) 300-100
(K) 300-20
(K)
DT4E ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 1 |
852b3edc-fb54-4a13-8a06-7135708c7e42 | cool the HTS -P1-5t and the 1G -HTS leads, respectively. The power feedthroughs have a current capacity of 600
A at room temperature, while the 1G -HTS leads have a
maximum current capacity of 900 A at 77 K. The 1G -HTS
leads prevent j oule heating and conductive heat loads from
being transferred to the HTS -P1-5t... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 1 |
27735e48-863a-411e-95d0-1cf674e90408 | performance of the HTS -P1-5t and the 2G -HTS extend
leads. In addition, a copper radiation shield was installed
to reduce heat radiation from the dewar wall.
Figure 3: (a) Schematic of the thermal sensor and voltage
signal measurement setup, and (b) photograph of the
LHFD.
17th International Particle Ac... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 1 |
e69d6f83-9197-4bb1-a8ed-146375747b38 | COOL DOWN AND CHARGE
Figure s 4(a) and (b) present the total resistance and tem-
perature profiles during the cool -down process . The HTS -
P1-5t was cooled down to 50 K within 23 hrs. The steady -
state temperatures of T4 ( first-stage), T9 ( second -stage),
T10 (copper plate), T13 (HTS -P1-5t tape), and T14 (HTS ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 2 |
4757d1b8-0361-46ce-b5a4-02f80089e028 | fied using a two- wire resistance measurement. In addition,
the resistance across b -c of the HTS -P1-5t was accurately
measured using the four -wire resistance measurement
method, yielding values of 0.046 Ω at 300 K a nd 400 nΩ
at 53 K. This measurement includes the contact resistance
of one bolted joint. Figure... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 2 |
86933500-c5e6-40e2-a2ce-0a7f5ce1d979 | istics of the overall circuit, the HTS -P1-5t circuit, the 1G -
HTS lead circuit, and the corresponding Hall sensor signal after two thermal cycles. Figure 5(a) shows the current -
voltage characteristics of the overall system during three
charging processes, with the signals measured at the power
supply. Figure 5(b)... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 2 |
d59dcfae-0bfe-4a89-8210-a5b4f8dbdc62 | through the HTS -P1-5t tape during the three charging pro-
cesses. This indicates that the HTS -P1-5t is operating nor-
mally . Based on these results, the abnormal system voltage
observed in Fig. 5(a) was not associated with the HTS -P1-
5t tape and is instead attributed to insufficient heat dissipa-
tion in other co... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 2 |
ff4b16ac-0e99-417a-8037-1ce9604716c1 | in the temperature range of 80 -95 K. In addition, the four -
wire resistance measurement of HTS -P1-5t at 53 K yielded
a low resistance of 400 n Ω, including the contact resistance
of one bolted joint. Furthermore, charging tests verified by Hall sensor signals demonstrated that the excitation current was applied to... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 2 |
bdef842a-a725-4d42-a7e1-7ff01236f792 | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7661
MC7.T10: Superconducting Magnets 1719TUP: Poster session TUP7661
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work,... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 2 |
525508b5-008f-458e-9a17-234a05706287 | REFERENCES
[1] B. G. Koshy, M. Ainslie, Y . Sun, B. P. P. Mallett, and Z. Jiang,
“Numerical study of dynamic resistance and total loss in in-
sulated and non-insulated HTS REBCO double -pancake coils
at 77 K” , Superconductivity , vol. 16, no. 100216 , 2025.
doi:10.1016/j.supcon.2025.100216
[2] H. Song, D. Hazel... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 3 |
0a4838e2-4f87-41c3-8ef3-545afb2b788d | Supercond. , vol. 31, no. 2, no. 9285175, Mar 2021.
doi:10.1109/TASC.2020.3042829 [4] J. C. Jan, C. C. Tsai, P. K. Wang, and F. Y . Lin, “Magnetic
circuit design and consideration for HTSW using 12 mm HTS tape”, in Proc. IP AC’2 5, Taipei, Taiwan, Jun. 2025, pp.1822-
1825.
doi:10.18429/JACoW- IPAC2025- WEPB... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 3 |
d7ccfaa9-64e8-4355-b47e-b88f484206df | tures , Springer -Verlag Berlin Heidelberg, 2013 .
doi:10.1007/978- 3-642- 35335- 2_2 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7661
1720 MC7.T10: Superconducting MagnetsTUP7661 TUP: Poster session
Con... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7661.pdf | 3 |
b85315ad-5d0d-4b32-8451-2afd39dbeeaa | DEVELOPMENT OF A FAST -FEEDBACK DEFLECTOR MAGNET POWER
SUPPLY FOR THE NEXT GENERATION HEAVY ION THERAPY*
K. Okamura†, K. Takayama, High Energy Accelerator Research Organization, Tsukuba, Japan
H. Kamezaki, Pulsed Power Japan Laboratory Ltd., Kusatsu, Shiga, Japan
Abstr act
Application of a 10 Hz fast -cyclin... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 0 |
b0177233-d902-48d3-b546-ffaf42774e74 | France. To enable precise targeting, the final deflector magnet must adjust the beam on its irradiation position ac-
curately by varying the polarity and peak current value for
each pulse with the excitation pattern of the main magnet system. The developed power supply for the final deflector
magnet makes this possi... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 0 |
93f91aa5-62d5-4a18-b00a-e5e43dba509d | induction synchrotron ( IS) [1, 2] with these features. Its
driver is the rapid -cycling IS that is operated at 10 Hz . In
the ESCORT system, the beam extracted from the accelerator ring is scanned not only across the entire 2D
cross- section of th e irradiation target, but is also swept in
depth; for this purpose... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 0 |
aaf72072-2f76-4364-b0a2-892e0d450771 | cancer target; we refer to this as the fast feedback deflector
system ( FFDS). This paper describes the magnet power
supply in the FFDS that can provide the peak current am-
plitude and polarity in response t o the command values
varying each acceleration cycle.
EXPERIMENT WITH A PROTOTYPE
POWER SUPPLY
Cir... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 0 |
6b7b7595-3b74-45bb-9d80-fdcc0394038d | Figure 1: Conceptual diagram of the E SCORT .
________________________________ ___________
* This study is supported by by Grant -In-Aid for Scientific Research (B)
(KAKENHI No. 23H03666
†katsuya.okamura@j -parc.jp 17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN:... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 0 |
957d6f4f-c82c-4f2f-86b2-da9eff5d9e93 | Figure 2: Schematic diagram of the prototype power supply .
Experiment
Experimental Setup Figure 3 shows the experimental
setup. The digital pulse generator generates a pattern start
signal for the arbitrary waveform generator and a gate en-
able signal for the prototype power supply.
Figure 3: Experimental s... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 1 |
36046e74-09b3-4d41-8254-2d75078e3d57 | start and end of the setup pattern. The measurement was
executed 5 times at each setup current. Figure 6 show s the
dependance of the current tracking accuracy on the setup
current . The fact that there is a deviation even when the
command value is 0 A is due to the above -mentioned offset .
Figure 4: Singl... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 1 |
e0159ef2-01d9-4b3a-aab7-1b4bf617bbb0 | magnet made from thin laminated steel plates was used as
a deflector magnet to minimize eddy current effects . Spec-
ifications of the magnet is shown in Table 1.
Table 1: Specifications of the Steering Magnet
Item Value
Gap Length 160 (mm)
Pole Length 210 (mm)
Inductance 4.3 (H)
Resistance 11 (Ω)
T... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 1 |
65391d13-aa26-40df-baea-0d9ee681b70c | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7666
1722 MC7.T11: Power SuppliesTUP7666 TUP: Poster session
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publishe... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 1 |
644a089d-f5a7-4c6a-93e0-f63e549062d9 | pulse pattern measurements were performed to investigate
the effect of magnetization induced by the preceding pulse
on the subsequent pulse. In the double -pulse pattern, the
peak of the first pulse was fixed at 3 A, while the peak of
the second pulse was varied from 3 A to - 3 A. Two exam-
ples of the double puls... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 2 |
042bb21a-0158-49b8-ba64-340445eb7c5d | Figure 10: Magnetic field vs. current .
Figure 11: Magnetic field difference between single pulse
and double pulse .
Figure 10 compares the magnetic field measurement re-
sults obtained using a single pulse with those obtained us-ing a double pulse. There is little difference between the two sets of results. Figur... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 2 |
ce5f4038-25aa-4012-b196-c9f4872a96bf | error on beam deflection error. Figure 12 shows the geo-
metric assumptions.
Figure 12: Geometric assumptions for discussing deflection
errors .
As can be seen from Figure 1 2, the relationship between
the magnet length L₁ , bending radius 𝜌𝜌 and the deflection
angle θ is expressed as follows.
𝐿𝐿1=𝜌𝜌∙... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 2 |
175639fd-e8ce-496d-b494-162dde4ba507 | fore the deflection length with the field error is
𝑦𝑦=𝐿𝐿1∙𝐿𝐿2
𝜌𝜌0∙(1+𝜀𝜀)=𝑦𝑦0(1+𝜀𝜀) . (4)
It is concluded that the error in deflection is compa-
rable to that in the magnetic field. According to the re-
sults of this experiment, the error in the magnetic field
depends almost entirely on the current tra... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 2 |
ba71d152-76a0-4a4d-a0d2-7971bb45c48f | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7666
MC7.T11: Power Supplies 1723TUP: Poster session TUP7666
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publishe... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 2 |
00ca54f5-5334-491b-8e8b-183b795630bf | REFERENCES
[1] L. K. Wah, T. Monma , T. Adachi, T. Kawakubo, T. Dixit, and
K. Takayama, “Compact hadron driver for cancer therapies
using continuous energy sweep scanning,” Phys. Rev. Accel.
Beams , vol. 19, no. 4, Apr. 2016.
doi:10.1103/physrevaccelbeams.19.042802
[2] K. Takayama, T. Kawakubo, T. Adachi, T. ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 3 |
6995b2a1-b2eb-4fdf-a4d6-c8090ba93c74 | ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7666
1724 MC7.T11: Power SuppliesTUP7666 TUP: Poster session
Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title of the work, publishe... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7666.pdf | 3 |
314cffba-67b4-4e21-b1bc-c7bcf2af253c | DEVELOPMENT AND EXPERIMENTAL VALIDATION OF A MODULAR
MAGNET POWER SUPPLY FOR THE KOREA -4GSR STORAGE RING
Hyeonjun Jang, Wi -Min Kim, Min -Kyu Choi, Yoon Geol Choi, Garam Hahn, Min- Jae Kim
Pohang Accelerator Laboratory , Pohang, South Korea
Abstract
The Korea 4th Generation Synchrotron Radiation (Ko-
rea-4GSR)... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 0 |
d5629d95-368a-4198-bd84-1fbfbfee29a3 | MPS) rated at 140 A, designed with master –slave parallel
operation capability to expand the rated output current to
280 A through two -unit parallel configuration. Operating -
condition -dependent calibration methods are appli ed to
satisfy the performance requirements over the entire oper-
ating range. Experimenta... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 0 |
5a2056a3-9f37-49a6-91b8-0334e13e80b5 | currents of 140 A or 280 A with a current accuracy below 100 ppm and stability below 10 ppm to ensure beam sta-bility and low -emittance operation. A modular 140 A -rated
unit featuring master –slave parallel operation was devel-
oped to cover both current ratings with a single MPS type ,
enabling expansion to 280 A ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 0 |
0a88481a-9e05-4119-a499-62bfe67a01b6 | switched -mode power supply (SMPS) and converted to DC to form the DC- link voltage. This DC -link voltage is
supplied to a full -bridge inverter based on SiC MOSFETs
operating at a switching frequency of 100 kHz. The high -
frequency ripples generated by the inverter are attenuated via an LC –LC–RC output filter , d... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 0 |
4b51ca44-9e3b-431d-b01b-951c3f7a9cb6 | slave feedback (current, status, and faults).
Figure 2: Power stage of the SR Modular MPS.
ACCURACY IMPROVEMENT
VIA CALIBRATION
Offset Calibration
Offset calibration is implemented to reduce the fixed de-
viation between the command current and the measured output current. The rated current range (1 –140 A)... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 0 |
ec077289-60e3-4c5c-bb36-91b0ab356176 | term operation. A thermocouple is mounted on the sensor
board housing the analog- to-digital converter (ADC) to ac-
quire real -time temperature data. The MPS is operated at
the rated current of 140 A over an extended period, and the
resulting temperature –current correlation is used to derive
temperature -dependen... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 0 |
4983047f-c97b-4505-918e-80d7947cf66c | Figure 3: Offset and temperature calibration of SR Modu-
lar MPS.
EXPERIMENTAL RESULTS
The main parameters of the SR Modular MPS are sum-
marized in Table 1. Two units of the SR Modular MPS pro-
totype were fabricated, and offset and temperature calibra-
tions were applied as described above. The performance was e... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 1 |
3c0f414c-5371-44ff-9bfa-2de2953f9614 | while the parallel operation (280 A) achieved an accuracy
of 45.88 ppm and a stability of 5.1 ppm. Both configura-tions satisfy the target specificati ons of 100 ppm accuracy
and 10 ppm stability, confirming the feasibility of the pro-posed modular design for the Korea -4GSR storage ring.
Table 1: Main Parameters o... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 1 |
82c42a2b-0dce-4fef-8fc6-80cf6192d21c | racy in parallel operation.
CONCLUSION
A storage ring modular magnet power supply rated at
140 A was developed for the Korea -4GSR storage ring.
The modular design with master –slave parallel operation
capability enables the rated output current to be expanded
to 280 A through two -unit parallel c onfiguration, ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 1 |
ea5f72d8-e2dd-4c9b-bed2-88be7dda0eb7 | maintenance efficiency. Offset and temperature cal ibration
methods were implemented to satisfy the stringent current
accuracy and stability requirements. Experimental re-
sults showed an accuracy of 45.79 ppm and a stability of
2.28 ppm in single -unit operation, while parallel operation
yielded 45.88 ppm and ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7668.pdf | 2 |
64ac03ec-3534-4357-b5c7-8a69148c2698 | DEVELOPMENT OF A Ga N-FET- BASED FAST CORRECTOR MAGNET
POWER SUPPLY FOR THE TPS
B. S. Wang, K. B. Liu, and Y . S. Wong
NSRRC, Hsinchu, Taiwan
Abstract
A modular GaN -FET-based fast corrector magnet power
supply has been developed for the Taiwan Photon Source
(TPS). The high switching speed of GaN devices enab... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 0 |
36639251-65d6-4143-b9d6-cb214d4e20f1 | rent re solution by optimizing the internal turn ratio of the
DC current transformer (DCCT). A digital control archi-
tecture is implemented, integrating an ADC interface, in-
terlock protection, and a PI controller, and is fully compat-ible with the TPS control system . With a switching fre-
quency of 250 kHz, the pr... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 0 |
5da6b6f1-e2ec-4ac2-b6ec-cb13455b2cc6 | suppressing rapid orbit disturbances .
The TPS storage ring consists of 24 sectors, each
equipped with bending, quadrupole, and sextupole mag-
nets, as well as seven beam position monitors (BPMs) as
shown in F ig. 1 [1].
Figure 1: Distribution of BPMs and f ast CMPS .
The FOFB system relies on fast corrector ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 0 |
88c31ac0-f578-4ef2-baaa-8d35c7a8d6bb | ture. Experimental results demonstrate enhanced band-width and current stability, validating the proposed system .
DESIGN OF THE DFCMPS
To increase the control bandwidth of the FOFB system
at TPS, a DFCMPS has been developed based on the archi-tecture of the existing TPS Corrector Magnet Power Sup-
ply (CMPS). The ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 0 |
8efc5873-fc3d-41cc-b8c6-ca89fa79b0c8 | closed -loop current regulation [3].
For current feedback measurement, a high -precision
DCCT is used. A LEM ITN -12-P DCCT operates in a
shunt -type configuration. By modifying the primary wind-
ing turns ratio, the current measurement range is reduced from 12.5 A to 6.25 A, thereby improving the current
measurem... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 0 |
3cf102a3-54af-429d-be44-ae157ad3bf43 | mance. The modular half -bridge design also simplifies sys-
tem debugging and facilitates future upgrades of the power
devices.
Figure 2: Architecture of DFCMPS.
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 0 |
f08719b2-0929-44bc-9105-f799add932c7 | GAN-BASED HALF -BRIDGE POWER
STAGE DESIGN
This study investigates power converters based on GaN
MOSFET switching devices. Several GaN devices with
different packaging types and driving characteristics were
evaluated. Corresponding isolated gate -driver circuits
were designed to implement modular half -bridge pow... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 1 |
0b05ed63-4c42-4e1c-a033-fce982608b01 | high- speed layout guidelines provided in the device
datasheets to minimize parasitic inductance and switching noise. The module dimension is 52.85 mm × 44 mm,
which is defined as the standard footprint for all GaN power modules developed in this work.
Based on this standardized design, several half -bridge
power... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 1 |
8f48e1cb-b96a-4f63-8d51-51430f7172da | creased from four to eight, which doubles the magnetic
flux generated by the measured current. Consequently, the measurable current range is reduced from 12.5 A to 6.25 A,
improving the sensitivity and resolution of the current
feedback s ignal. This modification enhances the accuracy
of closed -loop current regula... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 1 |
03e6b64a-7499-4cf2-8f23-c71c731d3261 | 25 μs, providing about 4000 CPU clock cycles at a
150 MHz DSP clock, which is sufficient for floating -point
computation. However, when the switching frequency in-
creases to 250 kHz, the interrupt period decreases to 4 μs,
leaving only about 600 CPU cycles available. Under this
condition, floating- point calcula... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 1 |
94fd130c-53f9-4c93-af4a-8337e0f8f292 | computation, while PWM2 and PWM3 maintained normal modulation. In contrast, with floating -point computation,
the interrupt frequency decreased to 406 kHz, and the
PWM signals could not operate correctly.
Figure 5: Timing differences in DSP algorithm .
EXPERIMENTAL RESULT S
Several experiments were conducted ... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 1 |
611bf9a8-72b6-4c3e-89d5-e43065a2a8a0 | compatible with the current TPS CMPS system.
Figure 6: Hardware of the DFCMPS with GaN modules.
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-TUP7669
MC7.T11: Power Supplies 1729TUP: Poster session TUP766... | D:\Daily_ihep\Conferences\IPAC2026\TUP\TUP7669.pdf | 1 |