4486777b-1276-4112-8af8-345a8b6731d1
17th International Particle Accelerator Conference, Deauville, France JACoW Publishing ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6074 2726 MC6.T03: Beam Diagnostics and InstrumentationWEP6074 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (©...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6074.pdf
3
b1bc5709-bca9-4671-bac3-3ab690a9588b
THE QUADRUPOLAR COMPONENT OF THE ESS LINAC PROTON BEAM B. Bolling∗, N. Milas, European Spallation Source, Lund, Sweden J. Cederkäll, B. Meirose, Department of Physics, Lund University, Lund, Sweden Abstract BeamPositionandPhaseMonitors(BPMs)areusedas part of normal routines to measure the dipole component of a charged ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
0
ff8cbd90-7168-420c-a258-4b56db37a172
sis on the relation between pickup sensitivities and beam parameters,andacalibrationstrategybasedonmeasuring thequadrupolarsignalsensitivitywithrespecttothebeam centroid position. INTRODUCTION BPMsconstituteafundamentaldiagnostictoolinparticle accelerators,providinginformationonthedipolecomponent ofthebeamtodetermineit...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
0
a1cf174f-a2b8-4b02-9cab-be57f9a8a3c6
opportunity to exploit quadrupolar BPM signals for high- power proton beams. This paper develops the theoretical basis for quadrupolar signal formation, proposes a method- ology for calibration and validation, and outlines a mea- surementstrategyatESSusingBPMs. Figure 1illustrates the design of the BPMs in the Spoke (S...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
0
601890f3-21be-409c-be08-8626d69b99a7
quadrupole doublet. The quadrupolar component is defined as Ξ = 𝜎2𝑥−𝜎2𝑦+ ̄ 𝑥2− ̄ 𝑦2, (1) ∗benjamin.bolling@ess.eu Figure 1: SPK and elliptical (MBL, HBL, HEBT) LWU sections’ BPM design (left) and a SPK BPM photograph (right). where𝜎𝑥and𝜎𝑦arethermsbeamsizesinthetwotransverse planes, and ( ̄ 𝑥, ̄ 𝑦)are the be...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
0
e5f8df52-4768-4140-a907-d85ce9b44779
Δ𝑥=𝑈𝐿−𝑈𝑅 𝑈𝐿+𝑈𝑅, Δ 𝑦=𝑈𝑇−𝑈𝐵 𝑈𝑇+𝑈𝐵.(3) Duetotheunavailabilityduringthetimeofstudyofbeam invasivediagnosticinstrumentstodirectlymeasurethebeam profileatgivenlocations,thesensitivities 𝑆𝑄werecalculated based on BPM design parameters and through calibration. CALIBRATION AND DATA ANALYSIS Thecharacterizati...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
0
3e6f47b8-5d3e-454a-a2fd-8723a7e828b8
ally resulted in scans performed with a non-zero offset in the non-scanning plane (e.g., a vertical offset ̄ 𝑦0during a horizontalscan). Thisoffsetintroducesaparasiticshiftin the signal baseline. To recover the real geometric response, acorrectionprotocolwasimplementedto”align”thedata17th International Particle Accele...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
0
878e2423-85be-493e-bad1-e53b0db4206e
Figure 2: Calibration surfacesforselected BPMs points utilizing a fitting as a function of both the horizontal and vertical offset, i.e., ΞΔ/Σ= 𝑆𝑄( ̄ 𝑥2− ̄ 𝑦2)+𝑐 (4) where𝑐 = 𝑆𝑄(𝜎2𝑥−𝜎2𝑦)is considered to be constant. To visualize the fitting, two-dimensional surface fits of the quadrupole signal were employe...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
1
afc62419-7b79-489d-b61f-40c03322bed5
(SPK) and Medium-Beta (MBL) sections, accurately re- flecting the mechanical increase in beam pipe radius. Fur- thermore, the symmetry between horizontal and vertical extractions validates the geometric integrity of the BPM pick-up electrodes. Analysis of the fit coefficients reveals high consistency across the linac s...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
1
c6f3571a-03ce-4fee-ab32-e92b95613121
MBL 30.8 7.87 +/- 0.3 3.61 +/- 0.2 HBL 30.8 8.14 +/- 0.3 0.929 +/- 0.3 that the calibration is able to capture the mechanical scaling of the BPMs in the physical machine. This provides high confidence in the transfer of the calibration values to the analysisofthequadrupolarcomponentofthebeamutilizing the BPMs in the HE...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
1
91435905-0a26-4967-93a4-b4cc675b9614
and with no energy dependency given that the same results wereobtainedwithboththe90MeVandthe800MeVbeam. As the BPMs in the MBL, HBL and HEBT sections have identicalmechanicalgeometry,MBLcalibrationresultsas definedinTable 1weretransferredandimplementedaspart of the analysis of the measurement results in order to de- ri...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
1
c619901b-0bab-486d-88a0-ec60fcb7ec4e
confirms the localized nature of the beam envelope modula- tion, with high-amplitude oscillations observed downstream oftheperturbationsourceprovidingabenchmarkforthelat- ticephaseadvanceandhenceallowsfordetectionofgradient scaling errors in individual magnets’ magnetic fields. MODEL COMPARISON Toevaluatetheaccuracyofe...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
1
b507611e-d6ac-47c9-9098-c9df978fdb18
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6075 2728 MC6.T03: Beam Diagnostics and InstrumentationWEP6075 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
1
0ebb416c-d814-43ca-9b99-479aeb41f83d
Figure 3: Perturbation of a QH and QV pair situated in the HEBT-080 LWU (with the blue and red dotted lines annotating their respective location) and the resulting BPM responses. The top plots shows the beam quadrupolar component for the”Golden”setting(greenline)andperturbationsintheotherlines,whilstthebottomplotsshows...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
2
60e394c4-4c01-48da-99d9-2816b99809e3
parisonrevealsthatthereisadiscrepancybetweenthemodel andthemeasurementpriorandfollowingthelocationofthe perturbation attributed to initial beam mismatch, including unknown Twiss parameters at the HEBT section entrance. AnalysisofthebottomplotsofFig. 3,i.e.,the”Offsetfrom Golden”, the parasitic effects of the mismatched...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
2
45a510ae-6d2a-4bb7-a68d-f60cad0fd4d0
beam quadrupolar component using the standard BPM sys- temattheESSSCL.Theimplementationofa2Dsurface- fitting calibration decoupled geometric sensitivies from par- asitic beam drifts, establishing calibration factors that scaleaccuratelywiththemechanicalapertureoftheBPMspecies included in the study. While the ”Offset fr...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
2
eae10c47-9ec0-44c0-9ab6-fd01ec9f5f5b
physicalmachine. Thesedifferencessuggestthatthestudy iscurrentlylimitedbyuncertaintiesintheinitialbeamdis- tribution and potential systematic offsets in the absolute normalization of the quadrupolar signal. Futureworkincludesimprovingthequalitativeanalysis followed by •Furthertests: Requiredinorderto understandthedis- ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
2
d82c3d00-7f1b-4d08-919d-51fdf2757468
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6075 MC6.T03: Beam Diagnostics and Instrumentation 2729WEP: Poster session WEP6075 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
2
e84a7f23-f167-4850-a194-70ce47dddabd
ACKNOWLEDGMENTS The authors would like to thank R. Baron (ESS Beam DiagnosticsGroup)forprovidingthetechnicaldesignspeci- ficationsandmechanicalsensitivityconstantsforthevarious BPMspeciesatESS,aswellasthediagnostichardwareil- lustrations. We especially appreciate their continuous avail- ability for technical discussion...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
3
66858373-ecb3-4002-9558-828861533793
[3]D. Alves, M. G, and T. Lefèvre, “Analysis of Quadrupolar Measurements for Beam Size Determination in the LHC”, inProc. IBIC’19 , Malmö, Sweden, Sep. 2019, pp. 397–401, 2019. doi:1/zero.alt4.18429/JACoW-IBIC2/zero.alt419-TUPP/zero.alt434 [4]OpenXAL Collaboration, “Openxal: an open source accelera- torphysicssoftwarep...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6075.pdf
3
3ec7ab8a-3de7-4b2d-a10c-f376e1ebda84
OFF-RESONANCE LANDAU CAVITY FIELD PROBE CALIBRATION D. K. Olsson∗, Å. Andersson, MAX IV Laboratory, Lund, Sweden Abstract Higher harmonic RF cavities are used by synchrotron lightsourcesforlengtheningthebunchesinordertoimprove Touschek lifetime and increase incoherent synchrotron tune spread. The MAX IV 1.5GeVstorage r...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
0
b2b3d054-df22-4ee5-8dab-6ee875c8dcef
methodislessdependentontheaccuracyofthemodelshunt impedance. THE MAX IV 1.5 GEV STORAGE RING TheMAXIVlaboratoryhousestwoelectronstoragerings, the1.5GeVstoragering,andthe 3GeVstoragering. This paper will only treat the 1.5GeVring. Relevant parame- ters for this ring can be found in Tab. 1. The ring has two nominallyiden...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
0
4f1611ef-bbea-46c8-ac8a-1f4dde370c58
current, and 𝑅𝑠is the cavity shunt impedance. The probe loop calibration of the cavitycan be found by recordingtheprobeloopvoltageatanumberofcurrentsand fittingalinearfunctiontotheprobeloopvoltagevs. beam current. In the case of the passiveLandau cavitiesat MAX IV,𝑅𝑠/𝑄is found using Superfish [ 3], from which 𝑅𝑠...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
0
1c664568-3491-4772-bcbf-63593d93f467
OFF-RESONANCE CALIBRATION An alternative to the on-resonance probe loop calibra- tion is the off-resonance calibration. This method relies onapproximatingthetotalharmoniccavityfieldas asmall perturbation to the main cavity accelerating voltage and cal- culatingtheeffectthisperturbationhasonthesynchrotron frequency. Thi...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
0
31cf01f4-774d-490a-b6d3-9059f3e873bf
and𝑛passive harmonic cavities is 𝑉𝑅𝐹(𝜑) = 𝑉𝑀𝐶(𝜑)+∑ 𝑛𝑉𝐻𝐶,𝑛(𝜑). (4) The main cavity voltage is given by 𝑉𝑀𝐶(𝜑) = 𝑉𝑀𝐶0sin(𝜑+𝜑𝑠), (5) where𝜑𝑠is the synchronous phase, given by 𝜑𝑠= 𝜋−arcsin(𝑈𝑡𝑜𝑡𝑎𝑙 𝑒𝑉𝑀𝐶0). (6) Similarly, the harmonic cavity voltage is given by [ 2] 𝑉𝐻𝐶,𝑛(𝜑) = 𝑉𝐻...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
0
1ad3f722-cc42-4cf9-b403-17f0bb385f20
harmonicofthemaincavityfrequency, 𝜔𝑅𝐹,normalisedby the DC component [ 2]: ̃𝐹 = |̃𝐹|𝑒𝑖𝜑𝐹𝐹=ℱ[𝜌(𝜑)]𝜔=𝑁𝜔 𝑅𝐹 |ℱ[𝜌(𝜑)]𝜔=0|. (9) Theequilibriumbunchdensitydistributioncanbeexpressed as 𝜌(𝜑) ∝exp(𝑈(𝜑) 𝐸0ℎ𝛼𝜎2 𝐸2𝜋), (10) where𝐸0isthebeamenergy, ℎistheharmonicnumber, 𝛼is the momentum compaction fact...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
1
fc129184-f4d1-4c06-bae2-4be399e16039
thefollowingproportionalityofthesynchrotronfrequency holds [6] 𝑓2𝑠∝d𝑉𝑅𝐹 d𝜑∣ 𝜑𝑠. (13) Assuming one well-known synchrotron frequency, 𝑓𝑠0, andcorrespondingacceleratingvoltagegradientevaluated around the synchronous phased𝑉𝑅𝐹,0 d𝜑|𝜑𝑠, it is possible to calculatethesynchrotronfrequencyofaperturbedvoltage gr...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
1
aef0c953-1cc8-4564-83cc-a58f730d4957
suredsynchrotronfrequency, 𝑓𝑠,𝑚𝑒𝑎𝑠,toproducearesidual function𝑔(∑ 𝑛𝑉𝐻𝐶0) = (𝑓𝑠,𝑚𝑒𝑎𝑠−𝑓𝑠,1(∑ 𝑛𝑉𝐻𝐶0))2.(15) Forameasuredsynchrotronfrequency,thetotalharmonic cavity voltage can be found as the voltage which minimises Eq. (15). Measurement The probe loop calibration factor was found by recording the ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
1
f84235b0-3e2d-4f8e-a0c7-65672669d0b4
to the limited power of this feedback system, the maximum measurement current was 100mA, compared to the normal operational current of 500mA. Theoff-resonancecalibrationmethodisonlyabletomea- sure the total effective probe loop calibration of both har- moniccavitiesinthering. Thisresultsintheeffectiveprobe loop calibra...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
1
164c9bf2-9d61-49ab-8421-b001dfaa2bab
ing calculated harmonic cavity voltagevsthe sum of probe loopvoltagescanbeseeninFig. 1. Thismeasurementcor- respondstoanapproximatelyequalsignalamplitudefrom the probe loops of the two harmonic cavities. Inordertofindtheindividualprobeloopcalibrationfactor ofeachcavity,twoadditionalmeasurementsweredone. The ratio of Ca...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
1
17a8fde1-b12b-4d0f-92de-7b0362d91956
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6076 2732 MC6.T03: Beam Diagnostics and InstrumentationWEP6076 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
1
4fbadd46-838e-403c-a9ee-124c34f7a90e
0 10 20 30 40 50 60 70-1-0.500.511.522.5104 66006700680069007000710072007300Figure1: The measured 𝑓𝑠andcalculated ∑𝑛𝑉𝐻𝐶,𝑛vsthe sum of harmonic cavity probe loop voltage. The fields in Cavity A and B were approximately equal. 0 20 40 60 80 100-2-101234104 550060006500700075008000 Figure2: The measured 𝑓𝑠andcalc...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
2
33b83258-8d75-4e0e-95a1-5170d5d7d643
CF [V/mV] 95 % CI 𝐾𝑎 227.2 [211.8, 242.6] 𝐾𝑏 389.4 [370.6, 408.2] 𝐾𝑎,𝑜𝑛−𝑟𝑒𝑠 321.5 𝐾𝑏,𝑜𝑛−𝑟𝑒𝑠 406.5 Sensitivity Analysis The accuracy of the off-resonance probe loop calibration depends on the accuracy of the know quantities used in thecalculation. Inordertoestimatehowanerrorinavariable affects the resu...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
2
04d2f2f5-335d-4587-abca-3ba286a37576
loopcalibrationconstantwasfoundtobe 319.1V/mV,CI 95%[293.7,344.4], which is a reduction of 11.9%com- pared to the on-resonance calibration, 362.2V/mV. This reductionisinthesamedirectionandorderofmagnitudeas the one expected from previous measurements of the bunch profile [5]. The individual calibration factors, calcula...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
2
9d08d453-e4bc-4b4e-989b-1b32f9f63918
is significantly less dependent on an accurate value of 𝑅𝑠, making it useful in detecting potential errors in a modelled 𝑅𝑠. The method is reliant on an accurate measurement of 𝑓𝑠, which can generally be achieved to sufficient accuracy (order of 0.1%) by increasing the averaging. Its ability to findthecalibration...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
2
8451787e-6ac4-4304-9a90-a0f4d6e44662
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6076 MC6.T03: Beam Diagnostics and Instrumentation 2733WEP: Poster session WEP6076 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
2
f4fa30b7-c091-4c3d-8773-4fffe312b407
[2]P. F. Tavares, Å. Andersson, A. Hansson, and J. Breunlin, “Equilibriumbunchdensitydistributionwithpassiveharmonic cavities in a storage ring”, Physical Review Special Topics - Accelerators and Beams , vol. 17, p. 064401, 2014. doi:1/zero.alt4.11/zero.alt43/PhysRevSTAB.17./zero.alt4644/zero.alt41 [3]K. Halbach and R....
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
3
4227b104-b340-4ba7-9c32-6df41eae9b7b
2024. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt424-WEPR42 [6]H.Wiedemann, Particleacceleratorphysics .SpringerInterna- tional Publishing, 2019. [7]J.BreunlinandÅ.Andersson,“EmittanceDiagnosticsatthe MAX IV 3 GeV StorageRing”, in Proceedings of IPAC2016 , pp. 2908–2910, 2016. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt4...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6076.pdf
3
9bf63d38-9fdf-45ff-ab64-dac796ad23b7
A NEW ANALOGUE ACQUISITION FOR THE BPM OF CERN PS M. Bozzolan, European Organization for Nuclear Research, Geneva, Switzerland Abstract The bunch- by-bunch and turn- by-turn beam trajectory measurement system of the CERN PS accelerator has been in operation for several years. To ensure long- term reliabil- ity...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
0
976ec36f-8006-462c-ba41-fcab90edc5d3
creased dynamic range opens the possibility of measuring longer acceleration periods without gain switching and bet- ter resolution. Increased band width allows the measure- ment of more beam configuration, in particular with shorter bunch to bunch distance. However, improved perfor- mances come at the expense of pla...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
0
fc6623e1-bdc0-4aae-b1b3-7fbc20c47330
stream accelerators (SPS and AD) and to experimental ar-eas [1]. The bunch intensity range is from 5 ·10 9 to ~1013 charges per bunch with a minimum bunch to bunch spacing of 25ns . A versatile RF system allows complex bunch ma- nipulations like merging, compression, splitting and rota- tion. For the observat...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
0
a5f47f7a-8a32-46df-8124-c699e53fbe6d
a signal with amplitude proportional to the centr e of charge position [2]. Ideally the BPM system should measure the beam posi- tion of the individual bunches turn by turn, on every beam configuration and along all the beam cycle from injection to extraction , following the RF beam manipulations. This spe...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
0
8c43e632-4164-4b36-82d9-a4ff676dfcaf
ally allowing the acquisition of the full accelerating cycle without using gain switching that may cause the loss of bunch synchronization. The system in use can operate without gain switching on regions of the accelerating cycle (i.e. injection, extraction, etc.) but with limited performance if setup to acq...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
0
0184bd13-8e08-412e-815b-b5eff77dafbc
the system performances [3]. Low I mpedance (Low -Z) Architecture1 In the low impedance case ( below ~1kΩ loading imped- ance) , like the PS BPM system in operation (Fig. 2) with 200Ω loading impedance , the main advantage is a relative freedom in the location of the amplifier (e.g. low/free radi- ation zone ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
0
aa4d40fb-ab51-4a8b-86e7-4c22ae3ee803
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6079 MC6.T03: Beam Diagnostics and Instrumentation 2735WEP: Poster session WEP6079 Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
0
1dcca81b-4e33-4ea7-9479-cb3ebd091a14
The limitation comes from the high pass frequency re- sponse of the electrode with the cutoff (8MHz in the PS Low-Z BPM case) de fined by the capacitive source imped- ance and the resistive component of its load. The high pass response requires an active compensation to obtain , at the output of the analogue ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
1
c7dab08b-3e13-4a5e-9995-13645d03ff5e
For the consolidation of the PS BPM system a variant of the high impedance (hundreds of kΩ) architecture has been chosen to improve the system performance . However, be- cause a transmission line with impedance higher than few hundreds ohm is unfeasible, t he “basic ” Hi-Z configuration requires the amplifier ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
1
410bf6cc-5567-4534-b5af-dd686a56d7d6
bles for the connection (Fig. 3) . The frequency dependent impedance loading of the electrode is about 100kΩ at low frequency and 75Ω at high frequency thanks to the AC ter- mination needed to avoid the long line effect that would start from about 10MHz , well into the required system passband. Figure 3:...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
1
37f61f4f-5cf5-4ad5-adc8-8ee0fa57e292
the capacitive divider formed by the coaxial cable capaci- tance proportional to the cable length ( plus matching net- works and electronics input capacitances) and the pickup capacitance. The simulated time domain response to r aised cosine pulses of different amplitude 5ns long and 25ns spaced is also report...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
1
9bdc5a65-b15a-444f-9550-17613eb1ebc5
“White ’s” source follower [4]. Ahead of the buffer stage , a capacitive divider can be inserted using reed relays to at-tenuate signal of high intensity beams. Downstream of the buffer stage the hybrid coupler combines the signal s com- ing from the two opposite electrodes of one plane to pro- duce the sum and...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
1
f673b50c-3e06-4f77-ad39-3a0a79b18fa4
CERN mixed field radiation facility. JFET s and HBT have been tested unbiased up to 10kGy, with no impact on the final application, while a complete frontend has been irra- diated up to 3kGy without significant variation on the elec- trical measurements . This result should guarantee a life- time (considering only...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
1
ed85380a-c3c6-4aa3-91aa-9e4100cdf493
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6079 2736 MC6.T03: Beam Diagnostics and InstrumentationWEP6079 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
1
4aed5963-cfd6-4bdb-b789-34f30c78e068
plug- out/plug-in and a stock of spare s is foreseen for the replacement in case of failure. Reparation is also an option, when the activation of the module is not excessive. The bench measurements (Fig. 6) are obtained emulating the final tunnel setup (pickup assembly + 5ns cable + frontend electronics...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
2
8543b0fd-a17d-4eb3-9e15-98a7fe3f599d
Figure 6: Hi-Z frontend electronics frequency response . BEAM MEASUREMENTS The effect of the improved electrical performances is presented comparing a “TOF” high intensity single bunch proton beam acquired by two identical pickups located very close each other (~1m apart) in the PS ring . One pickup is equippe...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
2
7c6e7ea9-bac4-4ae2-b496-27b578785ab3
Dynamic R ange Since t he PS beam pickup (Fig. 1) has the combined plus and minus electrodes of each plane providing (almost ) 360 degrees radial coverage the sum signal integrated over the bunch length is proportional to the bunch intensity and independent on the beam position. The comparison of the BPM...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
2
02148ceb-f7ab-43d6-9c58-64d2c66edcde
(hatched) , while the Low-Z BPM (orange) is affected by the increasing charge density of the bunch starting at turn 261.3k when bunch rotation is applied . Position M easurement Finally, the position measurement (Fig. 9) of the Hi-Z BPM has better resolution and offset . The Low -Z BPM trace is affected b...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
2
e230ff8f-d78b-4214-acd7-4c0431370f55
signed frontend electronics is compatible with the radiation level expected on the foreseen amplifier locations . Three prototype system s are currently installed in the PS ring to further validate the reliability of the proposed im- plementation , and the installation is foreseen during the up- coming long shutdow...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
2
93abd7e3-5947-4d68-9829-11bd51583213
REFERENCES [1] E. Lopienska, “ The CERN accelerator complex layout in 2022” , CERN 2022 . https://cds.cern.ch/record/2800984/ [2] A.J. Sherwood , “Electrostatic induction electrode systems for beam -position detection ”, IEEE Trans. Nucl. Sci. , vol. 12, no. 3, pp. 925-928, 1965 . doi: 10.1109/ TNS.1965.432...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
3
1bb691a7-b328-460f-a48d-ac7f45eafe6d
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6079 2738 MC6.T03: Beam Diagnostics and InstrumentationWEP6079 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6079.pdf
3
7696cf68-9765-4ac8-910b-45a5aff462c0
NEW FINDINGS ON BPM CALIBRATION IN THE LHC J. Keintzel∗, M. Krupa, Y. Angelis, J. Dilly, V. Ferrentino, M. Le Garrec, J. Gray, D. Jacquet, K. Skoufaris, R. Tomás, J. Wenninger CERN, Geneva, Switzerland Abstract Accurate Beam-Position Monitor (BPM) calibration is essential for high-quality optics measurements and reli- ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
0
5085fb13-ef8f-4e2a-a413-b5a6ddedafe7
been fully understood. This contribution presents the in- vestigations that enabled the identification of the bias, open questions, and implications for future operation. INTRODUCTION TheLargeHadronCollider(LHC)[ 1]atCERNwithap- proximately 27kmcircumferenceiscurrentlyinhislastyear of operation for Run 3 and achieves b...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
0
b9e6434f-b016-4e4b-8a42-98354e6887c5
jection and top energy of, respectively 450GeVand up to 6.8TeV, taken between 2016 and 2022, with 𝛼𝑐, between 3.2 × 10−4and3.5 × 10−4[3,4]. Additionally, in 2022 a novel optics with a transverse phase advance of 60∘in the arc FODO cells, 30% lower compared to the nominal LHC optics which features roughly 90∘, and has...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
0
30bd7a44-5078-49e2-b75d-440948a4df46
re-analysed in early 2025. Consequently novel polynomials havebeenappliedatthestartof2025. Withthesenewset- tingsopticsmeasurementsareacquiredin2025and2026, at various configurations. Main findings are reported here. ∗jacqueline.keintzel@cern.ch60∘OPTICS MEASUREMENTS IN 2024 A60∘optics has been designed and measured in...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
0
5896918f-8250-49a1-b1bb-15f71311832d
performed usingomc3 [ 6]. Foroff-momentum optics mea- surements, RF-frequency shifts of ±50Hz,±100Hz, and ±150Hzareapplied. Globalopticscorrectionsarebasedon a response matrices including horizontal and vertical tunes, phaseadvancesandnormalizedhorizontaldispersion,and all available quadrupole circuits [ 1]. Correction...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
0
878a691d-338b-45e4-8703-7dcc6ab43bed
applyingglobalcorrections,thermshorizontaldispersion deviation is reduced from 64cmto16cmfor beam 1 and from66cmto30cmforbeam2. Verticallythermsdisper- sion is roughly 0.2m. This optics is hence considered to be sufficiency well corrected to analyse 𝛼𝑐and hence BPM calibration. Figure1: Beam1horizontal(top)andvertica...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
0
48f6fd2c-ced8-4c7c-8ca8-d40cc3960367
Figure2: Beam1horizontal(top)andvertical(bottom) 𝛽- beating before and after applying global corrections. Similar to [ 3] it is aimed to measure 𝛼𝑐by comparing therelativemomentumoffsetobtainedfromtheorbitdata in combination with the model dispersion, with the rel- ative momentum offset obtained using the RF-frequen...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
1
eb7e4d71-9062-4220-8cef-dd8b8e9a96b2
ItisshowninFig. 3. Theerrorbarreflectsthefittingerror using a least square fit technique. Since the same system- atic error is measured for optics measurements at various machine configurations for both beams it is attributed to an average arc BPM calibration error. Figure 3: Measured compared to model 𝛼𝑐for beam 1 (...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
1
6d715692-22c7-4e19-95bc-a870aed2b670
quasi-2DelectrostaticsimulationswithCSTMicrowaveStu- dio [7]. Upon verification of the 2014 CST model it is discovered that some of its dimensions do not correspond tothetruearcBPMdesign,mostnotablytheBPMbutton electrode was modelled 14% too large. In the typical arc BPM measurement range of up to ±5mm, this would resu...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
1
04bc55d2-d5fa-45dd-aae6-e34958ffe064
in Fig.4. Figure 4: Residual beam position measurement errors of arcBPMsintroducedbythe2014(top)and2025(bottom) polynomial. MEASUREMENTS IN 2025 AND 2026 Sincebothindependentanalyses,basedeitheronopticsor onCSThavefoundasystematicaveragearcBPMcalibration errorofroughly 2.5−3% ,thenewlyderivedpolynomials, seealso[8],hav...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
1
2ea84d38-c7b0-4456-aaac-408f25e50f88
Table 1: Relative Deviation Of 𝛼𝑐For Beam 1, Given In % Date Optics 𝐷𝑥 𝐷𝑥and𝐷(2)𝑥 11/04/25 11 m −3.36±0.40 −3.35±0.87 20/04/25 11 m −3.91±0.23 −3.62±0.17 26/02/26 11 m −3.40±0.38 −3.17±0.35 12/04/25 2 m −0.57±0.25 −0.48±0.21 13/04/25 60 cm −0.71±0.71 −0.09±0.88 13/04/25 1.2 m −0.45±0.30 −1.75±0.11 26/02/26 1.2 ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
2
ce2ac1d7-0a46-4d40-8185-4dea9b10e010
11/04/25 11 m −3.08±0.68 −2.08±0.74 20/04/25 11 m −3.47±0.33 −2.58±0.11 26/02/26 11 m −3.33±0.46 −2.11±0.74 12/04/25 2 m −0.43±0.16 −0.11±0.22 13/04/25 60 cm −0.64±0.63 −1.43±0.85 13/04/25 1.2 m −0.35±0.37 −0.34±0.49 26/02/26 1.2 m −0.31±0.74 0.10±0.47 DISCUSSION Whilemeasurements attop energyclearlyreflect theex- pect...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
2
fdc88d91-4559-4d19-8a7b-70a68b34abb9
ments, compared to injection energy, e.g. 1nscompared to up1.7nson measurements at 26/02/26, this is not expected to introduce a significant scaling error in the arc BPM read- ings. Detailed analysis is still ongoing, however, first results indicate that the scaling error due to the bunch length varia- tionisexpectedto...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
2
00db95ec-7dc7-43d7-b30a-3a8618db5f6f
which, however, reproduced the findings on 𝛼𝑐. Second-order Dispersion The relative momentum off- set from orbit is re-calculated by a least-square fit including modelhorizontallinearandsecond-orderdispersionandthe measured horizontal closed-orbit. Results are also given in Tables1and2. Themeanvaluesare,respectivelyf...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
2
72c839dc-a23a-4a56-8d57-9551d6645df4
analysedmeasurements at top-energythe horizontal action is smaller by up to roughly one order-of-magnitude as seen inFig.5. However,obtaining 𝛼𝑐directlyfromorbitreadings do not show a clear dependence on the action, shown in the samefigureat √2𝐽𝑥= 0,nevertheless,thisanalysissuggests that the deviation without kicks...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
2
b31bbe74-2b09-4c40-ba5a-10b6ea5fc673
surementsremainunchanged. Arangeofpossiblesources hasbeeninvestigatedfrombothbeamdynamicsandbeam instrumentationperspectives. However,currentlynoclear source of this discrepancy has been identified. REFERENCES [1]O. Brüning et al., “LHC design report”, CERN, Geneva, Switzerland,Rep.CERN-2004-003-V-1, 2004.17th Internat...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
2
439b1f3c-8753-4e9a-a399-3c8560aa6eae
[2]G.Apollinari,I.BéjarAlonso,O.Brüning,P.Fessia,M.La- mont, L. Rossiand L. Tavian, Eds., “High-Luminosity Large Hadron Collider (HL-LHC): technical design report V.0.1”, CERN, Geneva, Switzerland, Rep. CERN-2017-007-M, 2017. [3]J.Keintzel,L.MalinaandR.Tomás,“Momentumcompaction factormeasurementsintheLargeHadronCollide...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
3
bfee468d-7eb0-437e-8907-d9c3f6ff3695
in the Large Hadron Collider at CERN”, in Proc. IPAC’23 ,Venice, Italy, May 2023, pp. 571–574. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt423-MOPL/zero.alt426 [6]L. Malina etal., “OMC3”, Zenodo, 2022. doi:1/zero.alt4.5281/zenodo.57/zero.alt45625 [7]CSTMicrowaveStudio, CST Studio Suite , 2026. [8]M.Krupa,“Geometricalnon-...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
3
2869358b-29cd-4760-9f6a-dca83bc433ee
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6080 2742 MC6.T03: Beam Diagnostics and InstrumentationWEP6080 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6080.pdf
3
919c202a-d82a-4bd4-b868-aeb965e61931
ADVANCING BEAM QUALITY CONTROL IN THE CERN PROTON SYNCHROTRON M. Coly, A. Akroh, Z. Ansari, A. Beeckman, D. Cotte, J. Flowerdew, G. Imesch, A. Huschauer, A. Lasheen, R. Maillet, J. Mccarthy, K. Sabin, S. Sainz Pérez, M. Schenk, Y. Wu CERN, Geneva, Switzerland Abstract Over the past years, the beam quality delivered by ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
0
ae49c08d-64a1-4609-aa9c-42d386c80b06
To address these challenges, a new beam quality moni- toring framework has been developed, building on recent enhancementsindataacquisitionandonlineanalysiscapa- bilities. Thesystemdefineskeybeamqualitymetricsinreal time,enablingearlydetectionofdrifts,root-causefaultanal- ysis, and provides the foundation for automated...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
0
7d0aa82c-0580-4beb-8c2a-928dd7f9a001
of CERN’s experimental program. INTRODUCTION The CERN Proton Synchrotron (PS) is part of the CERN injectorchainprovidingbeamsbothforfixed-targetexper- imentsandfordownstreamacceleratorssuchastheSuper Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The PS must deliver beams with a wide range of intensities...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
0
1695c917-e967-4884-843f-f4581f743c18
indicators of beam quality. Figure1: ConceptualarchitectureoftheBQMframework. Signalsfrom beam instrumentation,notablyBeam Current Transformers(BCT),WallCurrentMonitors(WCM),and Low-LevelRadioFrequency(LLRF)systems,areprocessed onlinetoderivebeamqualitymetricsforseveraloperational purposes. BEAM QUALITY MONITORING FRAM...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
0
d78bd1f3-9c6b-4e42-af19-260fd2a31de8
intheCERNControlCentre(CCC)supportingbothroutine operation and machine development studies. BQM USE CASES IN PS OPERATION Tohelptheoperationsteam,BQMmetricsareexposedin differentways,dependingonoperationalneedsandusecases. The following subsections present representative examples. Machine-Learning Tools: MTE Efficiency...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
0
5e4cd837-b245-4e39-a2a3-7e666731ffb2
splitting efficiency, is defined as the average intensity in the islands divided by the total intensity: 𝜂MTE= ⟨𝐼islands⟩/𝐼total. (1) In case of quality drifts, the operations team can use a machine-learning-basedoptimisationalgorithmtoadjustPS17th International Particle Accelerator Conference, Deauville, France JAC...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
0
ebb9b326-0029-443f-aeb4-c7f674581a5d
Figure2: SignalacquiredfromaBCTinthePSdownstream transfer line, from which the intensities of the five MTE beamlets are measured over time. The core is greyed out in the figure. The blue trace corresponds to a balanced intensitydistributionacrossthefivebeamlets,yieldingan optimal splitting efficiency of 0.2, whereas th...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
1
1b0084c0-bd13-41fc-8c7c-56383758d2f6
feedback (CBFB) system. As described in Ref. [ 3], the CBFB acquisition system provides measurements of the longitudinal beam behaviour at different harmonics in the formofin-phase( 𝐼)andquadrature( 𝑄)components,from whichtheamplitudeofthecoupled-bunchmodesignalMis obtained as: 𝑀(𝑡) =√𝐼(𝑡)2+𝑄(𝑡)2. (2) For each ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
1
fea2670d-51a6-482b-9439-c54011ef12eb
Luminosity(HL)-LHCReliabilityRun[ 4],allowingrapid identificationofdipolarcoupled-bunchactivity. Thederived observableis then published through the control systemand monitored in an operational GUI shown in Fig. 4. Figure3: RepresentativeCBFBdiagnostics. Thefirstrow correspondstoastablebeam,whilethesecondrowshows an un...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
1
081e45ce-dddc-45a6-b3c1-e2cbc296fb2d
arevisiblethroughoutthecontrolroom. Theircontentisalso distributed via a CERN-wide video stream, allowingteams in the experimental areas to follow machine status in real time. One of these displays is dedicated to the performance of LHC-type beams in the PS, in particular bunch-by-bunch intensity and bunch length (see ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
1
98454f59-b90d-4baa-938b-54bcf6bc423e
represents the linear baseline. Thefitisusedtoextracttheintensityandlengthofeach bunch. These observables are required to remain stable over time and as uniform as possible across all bunches withinthetraininordertomaintainabalancedbunchpattern, which is particularly challenging for high-brightness beams. Displayingthe...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
1
6c84e88a-d093-4bb3-a410-239be41cb8cb
ISBN: 978-3-95450-252-3 ISSN: 2673-5350 doi: 10.18429/JACoW-IPAC2026-WEP6081 2744 MC6.T03: Beam Diagnostics and InstrumentationWEP6081 WEP: Poster session Content from this work may be used under the terms of the CC BY 4.0 licence (© 2026). Any distribution of this work must maintain attribution to the author(s), title...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
1
2e17f4b6-f761-4f8b-abfa-407a92b66f1e
Figure4: OperationalBQMinterfaceusedintheCCC.Beam quality indicators are colour-coded according to predefined thresholds (green: nominal, yellow: warning, red: fault). usedtomeasurethetransversebeamprofile,fromwhichthe BQM derives the horizontal and vertical beam sizes 𝜎hor and𝜎ver. Thebeamintensity(I)ismeasuredbyaBC...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
2
abcb9be5-4b93-4ed1-934d-4230547c9fba
INTERFACE The application-oriented metrics, forming a subset of the broader BQM metrics, are integrated into an operational interface used in the CCC, shown in Fig. 4. The interface provides a compact overview of critical metrics for each beamtype,includingMTEefficiency,CBFBinstabilityin- dicators, longitudinal splitti...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
2
01f976a3-fd23-439a-8189-9a6d71371d46
areeasilyadjustableviaconfigurationfiles,makingtheGUI adaptive to varying operational requirements. This unified overview allows operators to react quickly incaseofdrifts,correlatedegradationsacrosssubsystems, and supports reliability runs with consistent beam-quality supervision. CONCLUSION A BQM framework has been de...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
2
cfa917d0-b6fb-4c10-b198-bae7e90c4361
The system combines beam instrumentation data with online analysisalgorithms to derivecompact indicators de- scribingbeambehaviour. Theresultingapplication-oriented metric set supports, for example, machine-learning opti- misation of MTE, GUI-based CBFB diagnostics, VISTAR monitoring of longitudinal splitting, and beam...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
2
91739de5-7dd9-4100-95e8-eb3c5fa9664f
future automation efforts, as it is building a comprehensive databaseformachinelearning,enablingadvancedpredictive analytics and optimization of operational processes. In the future, the approach could be extended to other CERN accelerators and enriched with additional observ- ables, such as transverse emittance measur...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
2
a367ba58-ca55-4508-a6a4-f6a12c57c9a1
multi-turnextractiontuningattheCERNProtonSynchrotron”, inProc. IPAC’25 , Taipei, Taiwan, Jun. 2025, pp. 2703–2706. doi:1/zero.alt4.18429/JACoW-IPAC2/zero.alt425-THPM/zero.alt4/zero.alt49 [3]H. Damerau et al., “Longitudinal Coupled-Bunch Instabilities in the CERNPS”, in Proc.PAC’07 , Albuquerque,NM, USA, Jun. 2007, pape...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
2
fadbb118-7533-4a30-88b6-24b95a8c8c1d
[4]Sainzet al., “Results from the HL-LHC proton Reliability RunintheLHCinjectors”,presentedatIPAC’26,Deauville, France, May 2026, paper THP4009, this conference. [5]A. Beeckman et al., “Real-time Monitoring of Longitudinal BeamQuality across theCERN AcceleratorComplex,” Nucl. Instrum. Methods Phys. Res. A , vol. 1086, ...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
3
d00cde17-4dcf-4ead-974b-bccba049d81f
terlocking System: A Modular Operator-Driven Approach to Equipment and Beam Quality Su- pervision,” presented at WAO 2025 . Available at: https://event.fourwaves.com/wao2/zero.alt425/abstracts/ 5ebb76/zero.alt4e-65be-493/zero.alt4-b9c6-1ceabb9f/zero.alt439f .17th International Particle Accelerator Conference, Deauville...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6081.pdf
3
e5f47fa0-e348-4e71-955b-e55f80967a0b
STUDYING COHERENT TRANSITION RADIATION SPATIAL IMAGE FEATURES FOR BUNCH LENGTH DIAGNOSTICS A. Guisao-Betancur∗1,2, C. P. Welsch1,2, J. Wolfenden†1,2 1University of Liverpool, Liverpool, UK 2Cockcroft Institute, Daresbury, UK Abstract Coherenttransitionradiation(CTR)hasbeenwidelyused fordevelopingdiagnosticsofparticlebe...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6087.pdf
0
801d6afd-1f5a-44c0-8dc0-f9b80110a6c6
such as the image width, can be tied to the bunch length. However,amorein-depthimageanalysisisrequired. Inthis work,anattemptismadetomodelsomeofthebunchprofile features from the CTR spatial images using conventional imageanddataanalysistechniques. TheCTRspatialimages aresimulatedinAnsysZemaxOpticStudioforabroadrange of...
D:\Daily_ihep\Conferences\IPAC2026\WEP\WEP6087.pdf
0