Problem Statement: When attempting to translate a steady state model in Aspen Plus to Aspen Plus Dynamics, I get the following error message:
Solution: If you have Polymers in your component list, go to the Properties Environment and use button reorder at Components > Specifications to make sure that the polymers and segments are placed in the first lines. Once you have changed the order of the component list, go back to the simulation environment, re...
Problem Statement: Swage is used in the Pipe segment in order to change the diameter of a Pipe segment taking into account accurate pressure drop an velocity change. However, in some occasions when reducing the diameter of the pipe segment the Swage gets ignored and you observe the following profile: As you can see,...
Solution: When using a Swage to reduce the diameter in a Pipe segment, what we see is that the reduction affects the velocity of the flow, increasing it abruptly and causing that the pressure decreases abruptly to compensate the kinetic energy increment. When the velocity of the flow increases until surpass the speed o...
Problem Statement: When launching Aspen Watch Maker, the following pop-up error message comes up: Run-time error ‘50003’: Unexpected error
Solution: This issue is caused by Microsoft Windows being outdated. Check your machine for any pending Windows updates and apply the most recent updates to resolve this error. Keywords: Watch, maker, run, time, error, 50003, ‘50003’, unexpected, error, windows, update References: None
Problem Statement: Why There is a Weird “SUL ppmw” Row in MBO HTML Reports?
Solution: First, the sulfur properties is usually defined as weight percentage (wt%). So why do we see this row in the HTML report of MBO that has “SUL ppmw” in it? “ppmw” stands for “Parts per Million Weight”. It is also a unit that measures towards weight. In MBO, if the SUL wt% is less than or equal to 0.01%, MBO...
Problem Statement: Why Do You See a Mismatch of Objective Function at the Top of the Full
Solution: Report and the Economic Summary Section? Solution The reason this is happening is because the top OBJFN is taken from the Matrix Analyzer and the OBJFN from Economic Summary is taken from the execution log. The solution to this is to uncheck “Use Tighter Bounds on Qualities”. The reason is because the mo...
Problem Statement: Why Sometimes You are Seeing Inconsistent Property Values in PRMAP and Final Matrix Analyzer?
Solution: The simple answer to this is the model has conflicting data. First, please check the execution log for W069s. AN example is as below: *** Warning. Property AAA for BBB in Table BLNALL Previously Defined What these warnings mean is the same data is defined in more than one place in the model and one has ov...
Problem Statement: The stream report in Aspen Plus from version V9 and on can be easily customized by selecting the properties to be displayed, adding properties and selecting the order of the displayed variables, and sometimes users need to use those reports in other simulations.
Solution: When the stream report is modified, the recommendation is saving this as a template, so you can use it for other streams. To save it as a template click on Save as a template, it will ask for a name, the description is optional. Then you can go to other stream reports and select this template to be used ...
Problem Statement: When modeling an Incinerator unit a Inlet Gas is required, as well as a Fuel Gas stream and an Air stream. However the only required flow is the Inlet Gas, for the other two only their composition, pressure and temperature are needed, how are those flows calculated?
Solution: The goal of the Incinerator unit is to convert the remaining particles of H2S in the tail gas clean up, thus the incinerator prioritizes the burning of the inlet gas stream. The incinerator does this using a fuel stream, since burning the acid gas stream requires energy, so the incinerator also needs a stream...
Problem Statement: After running the model, warning W617 “Property XXX in Row YYY Differs from ZZZ” is displaying in the Execution Log. How do I clear this message?
Solution: To clear this message check for any inconsistencies between the property in table ASSAYS and table INDEX or Property Calculation Formula. If you have verified there are no inconsistencies, but you are still getting the warning, check if the property giving the error is being calculated from two or more prope...
Problem Statement: How to stabilize recipes in Aspen MBO?
Solution: In blend operations, it is preferred to use similar recipes for a given product to reduce the complexity of blend execution. In Aspen MBO, there is a setting “Recipe Stabilization” to satisfy this requirement. Users could go to Settings>>Blend. Under Recipe Stabilization, enter a positive value for Deviation...
Problem Statement: It is common that users compare thermodynamic models between Aspen Plus and Aspen HYSYS such as NRTL and observe differences in VLE behavior of binary mixtures between both applications.
Solution: Aspen HYSYS and Aspen Plus have different databanks of components and have differences in the thermodynamic models used by them. NRTL model is exactly the same in both applications, however what is different is the form of calculating the parameters. NRTL equation is as follows: In order to match the VLE ...
Problem Statement: When entering the inputs of a stream, one of the flow options is Stdvol, which is standard liquid volume, but when looking at the stream summary the volume calculated is different even though it is at standard conditions.
Solution: The Standard Liquid Volume (Stdvol) basis uses the standard liquid volume property of a component (VLSTD) and its units are volume/mole, which is a property given at standard conditions, 1 atm and 60F, and it does not depend on temperature nor pressure, VLSTD property can be consulted in Methods|Parameters|...
Problem Statement: In occasions a simulation is running well and it converges, but after setting a Sensitivity Analysis and running again the simulation, it does no converge anymore.
Solution: This problem is not about the simulation but convergence, the Sensitivity analysis will run all the cases that has been indicated and, by default, it will run the base case at last, which means that if the manipulated variable has a large range of values, and the manipulated variable input in the base case ha...
Problem Statement: The incinerator is an adiabatic unit, so the real duty calculated using the heat flows of the streams is always zero, but when reviewing the Performance tab in the incinerator, it reports a Duty different from zero.
Solution: When modeling an Incinerator unit inside the Sulfur Recovery Unit, it requires an inlet gas feed, a fuel stream to burn it and an air stream for combustion. This unit is adiabatic and its duty is zero. The reported duty is different because the incinerator parts the process into two, it first calculates t...
Problem Statement: How to migrate Aspen Report Writer templates from old versions to V11 and beyond?
Solution: In V11, Aspen Report Writer is enhanced to support use of 64-bit Windows. The new function “Template Migration Tool” could be used to migrate old templates to new templates in newer versions, which mainly updates the directory path of RW functions from library AspenRpt.xlam. Template Migration Tool is located...
Problem Statement: How to copy a datasheet of one object from an existing datasheet of another similar object?
Solution: Often times a project may involve many equipment of the same type, it would be convenient to be able to use an existing equipment datasheet as leverage to create new datasheets of other equipment of that type. There is not a particular feature available to copy datasheet directly because this approach would c...
Problem Statement: When running cases in PIMS and using SQL server as an output database, no cases are running and the following error is showing: “The solution data was not written to the database. No reports will be created” This error has been registered when using “Microsoft OLE DB Driver for SQL Server” as the ...
Solution: To solve this error, go to General Model Settings > Output Database. Click the button with the three dots … next to “Connection String” field. In Data Link Properties window, go to All tab and check for any values in the Extended Propertied field. If there is something in this field delete it so it’s blank. ...
Problem Statement: How will MIN and MAX blank entries in process limit rows impact matrix L/G rows in V10 and beyond?
Solution: In Aspen PIMS, PROCLIM table is used to impose limits on process conditions and recursed properties in a submodel. ZLIMxxx and Zproxxx rows are used create process limits and in the matrix Z rows will be replaced by E, L and G rows. In V10 and later versions, if there is no entry for MIN or MAX of Z rows, the...
Problem Statement: Why am I getting Input Errors (like Error 1166) when running a Fired Heater? The specified flow sequence, through the convections banks and/or the firebox is inconsistent
Solution: Input Error 1166 concerns the flow history through the convection banks. For example, in the following screenshot the connections are then shown as in the second diagram. Stream 1 enters bank 3, then bank 1 and finally into the firebox. Stream 2 enters bank 2 only. The user will need to define the "Process ...
Problem Statement: How do I create a new Border Label?
Solution: See attached Word document for the procedure for creating new Border Label. You will find a "PPIDcustom" KB script that is ready to be use with "Example1" label file. Further instructions to compile "Example1" label and customize "PPIDcustom" script are provided in the attached document. Keywords: Border, Lab...
Problem Statement: Which license keys are required to use Datasheets within ABE V11?
Solution: The License keys used by the different ABE Servers when connecting from Simulator (Aspen Plus/Aspen HYSYS) are: Enterprise Server: License key - Aspen Zyqad when accessed from Datasheets button in Simulation or Safety Analysis environment (Aspen Plus and Aspen HYSYS). Local Server: License key - RN_EIE_ABE_...
Problem Statement: Is it possible to transfer data between heat exchanger design tools and ABE (Aspen Basic Engineering)?
Solution: Exchanger design is an important task and is typically done in tools such as EDR or HTRI. During the FEED phase, users may need to obtain process data either from the simulator or ABE and then store calculated results back to ABE workspace.The amount of information involved in this workflow is huge. Hence a...
Problem Statement: Project items cannot be claimed in Aspen Basic Engineering V11 Drawing Editor
Solution: In V11, to claim an item in the Drawing Editor, users will find that they cannot select the items in the drawing to perform claiming. To perform this function in V11, users will need to first claim the drawing to be either "Shared" or "Exclusive." This will make the drawing available to the project (claiming ...
Problem Statement: Stream Summary Datasheet does not populate stream data in the correct order.
Solution: There are two things to check when the user finds their stream summary datasheet not populating data in the expected order (skipping columns resulting in blank columns): 1. Verify the index set for the attribute. Open the stream summary datasheet in the Datasheet Definer and verify that the columns are set wi...
Problem Statement: Why are Dimension Set and Dimension Units options grayed out?
Solution: The Explorer interface provides the ability to change dimension set and dimension units for the entire workspace in Aspen Basic Engineering (ABE). Users, however, may find that these options are grayed out User likely does not have appropriate privilege in his role. Each user role is assigned a set of p...
Problem Statement: What are the different copy options in the Drawing Editor?
Solution: ABE has multiple options to copy an object. Below are descriptions of the available options: Copy: Users can create a copy of the existing object. This option will create a new object with attributes populated based on the original object. Data is only copied once. There is no live link between the two object...
Problem Statement: Why is ABE V11 Mapper Not Able to Transfer Second Liquid Phase Properties from HYSYS Simulation?
Solution: With ABE V11 and V10 Mapper integration inside HYSYS, users can selectively transfer desired stream properties (or referred to as attributes in ABE environment) to be used in their datasheets. However, users may find that properties for second liquid phase are not transferred even though the attributes are s...
Problem Statement: Name extension and limitations for the Workspace name in ABE.
Solution: The Workspace name has no extension limit for characters. The only characters not supported for names are the following: \ / : * ? < > | & Keywords: Workspace, Name, ABE References: None
Problem Statement: How to know if ABE V11 is installed in a user machine (Local Server)?
Solution: Since V11 for in Safety Analysis (for Aspen HYSYS and Aspen Plus) the Datasheets are now created with Aspen Basic Engineering (ABE). Please check the following article to know how: https://esupport.aspentech.com/S_Article?id=000065633 IMPORTANT: This information is to verify the installation of an ABE Local ...
Problem Statement: How to use KB scripts in ABE?
Solution: KB scripts are codes written in VB.NET programming language. KB scripts allow the user to access objects and data in the workspace database. The codes can be used to automate data editing process by applying prescribed rules. Below is the workflow to install and enable KB script for use in a workspace. It is ...
Problem Statement: Troubleshooting Offline-to-online task on Aspen Online projects
Solution: There are several ways offline-to-online task can fail, and each has its own troubleshooting workflows. If offline-to-online fails to load the model: Increase shared memory limit (see link) – once per machine. Use SQLExpress for APED – once per installation Fully initialize the simulator using the user accou...
Problem Statement: Why is the Plant Data feature not opening/working on my simulation?
Solution: The Plant Data feature is used to connect your simulation to plant data in a data historian and/or in an Excel workbook and schedule runs using the latest data to monitor plant performance. Plant Data achieves this by using another AspenTech product called Aspen OnLine. Aspen Online service must be running i...
Problem Statement: How does the CO2 Freezing Utility calculate its point?
Solution: Aspen HYSYS uses the selected property package (limited to Peng-Robinson and SRK) to calculate the fugacities of CO2 for different phases and equate them as a condition for the equilibrium. The triple point of CO2 is also used to compute the CO2 Freeze Out Temperature. Aspen HYSYS uses a modification of equ...
Problem Statement: What is the recommended procedure to migrate Aspen Basic Engineering from one version to another version?
Solution: The attached document explains the important steps that we recommend users to follow when migrating ABE to a newer version. Migration in ABE involves copying and re-compiling template files in the libraries folder. Users should use this document as a guideline to ensure template files are properly migrated. I...
Problem Statement: What is the scope of Rules and Global Methods? Do they apply to my sub-project workspaces?
Solution: When users create sub-projects in a master workspace. All KB scripts installed in the master workspace will be available for use in the sub-project. However, the scripts execution will be applied only to the currently logged in workspace. Sub-project is treated as a distinct workspace from its master workspac...
Problem Statement: For many pieces of equipment, very little (if any) data is transferred to the ABE equipment from the simulation. This is because the simulations are typically very conceptual. For example, in a simulation a drum may only be simulated as having one inlet stream. But in reality, it could easily have 3...
Solution: In the attachment, you will find a KB script that is used to run a Local Method on compressor objects. Install this KB script to your workspace before moving on. If you are not familiar with using KB script in ABE, please search for "How to use KB script in ABE?" article in our support site. One or more (pre...
Problem Statement: How do I improve performance in PIMS v11 when the model folder is on a network drive?
Solution: The xpress file format was changed to "full format" from compact in PIMS v11 due to random PIMS crashes that were due to an issue with the xpress compact format. The writing of the xpress basis files may cause the slower performance in PIMS v11 compared to PIMS v8.8 when a model folder is on a network drive. ...
Problem Statement: Organic Rankine Cycle example
Solution: The Organic Rankine Cycle or ORC unit is a system based on a closed-loop thermodynamic cycle for the generation of electric and thermal power, especially suitable for distributed generation. ORC systems can generate electric and thermal power exploiting multiple sources, such as renewables (biomass, geotherma...
Problem Statement: . The slug model concept is based on the principles from Bendikson (1984), where bubble/slug and mist flow models are implemented in the system.
Solution: . Transition from slug to mist flow is numerically considered as a limit of the bubble/slug model. When the Bendikson (1984) model option is selected, the C0 and U0 velocity parameters are calculated by HYSYS for the general form of the translational velocity Eq1. ...
Problem Statement: There are two different approaches that can be used to convert performance curves: 1. Convert operating point from off-design condition to reference condition, then calculate flow/head relation using the manufactory performance curves. 2. Convert manufactory provided performance curves from referenc...
Solution: Aspen HYSYS has always been intended to use approach 2, For V10 and newer versions, the equations are consistent with approach 2, which means that they convert manufactory provided performance curves from reference condition to off-design operation conditions. Derivation of the equation: We are considering...
Problem Statement: When modelling compressors and expanders, it is possible to link them to other compressors or expanders to represent that their shafts are physically connected, but doing this provokes that only one of the linked compressors gets mapped by APEA.
Solution: Linking compressors and expanders in HYSYS means that: 1. The speed of each linked unit operation is the same 2. The sum of the duties of each linked compressor or expander and the total power loss equals zero Linking compressors/expanders can be done in the Design tab, in the option Links, in the following...
Problem Statement: How to change the Mass and Molar Enthalpy sign?
Solution: It is possible to change the sign for the Mass and Mole Enthalpy values if the user needs to report in this form. Note: These steps are only for change the way Aspen HYSYS reports the value. This won’t affect the calculations. Please follow these steps: 1. Go to File | Options | Units Of Measure. 2. Copy ...
Problem Statement: What do I do if my Aspen Online interface doesn’t open?
Solution: If customer is having problems opening the Aspen Online Graphical User Interface (GUI), first review the services list to see if the service “Aspen OnLine V11.0” is running. Possible reasons for AOL service not running: Service startup type is set to Manual Service is set to Automatic, but the system is slow ...
Problem Statement: There is a yellow bar at the bottom while No error is found in Result | Message tab?
Solution: The yellow bar is due to the messages present in View | Error Messages: 'Networks where KO drums are present within a loop may not converge for multi-phase systems' In this case, it is saying multi-phase separators may not converge in looped systems. If the yellow bar is present, the user needs to verify ...
Problem Statement: When the user makes changes to a pipeline event, for example Crude Pipeline Shipment and clicks on Events -> Refresh, the event does not revert to its original state. For other type of events, clicking on Events-> Refresh brings them back to their previous state. Please refer to the attached document...
Solution: This is a known issue in APS and will be fixed in the upcoming patches in V10 and V11. Keywords: None References: None
Problem Statement: How to adjust indexes by location?
Solution: Location Indexing lets the user manipulate the costs of a Code of Account (COA) range to make the project prices more faithful to the project location data. To do Location indexing, follow the steps below: Right click in the Indexing form. Click Select. Any index files available are listed, select the on...
Problem Statement: . It is possible to import pre-build Flare models into a new Aspen Flare System Analyzer model, and there is no limit, but after trying to import more than 3 Flare models simulation crashes.
Solution: . Once you have imported the third model into AFSA follow the listed steps, to avoid crash issues: Save the file as new then. Close the new saved file. Open it again and import the missing models into the new one. NOTE: You must follow the pattern of saving a new file once you have imported a third model. T...
Problem Statement: When trying to convert the input file from PORII to HYSYS V11, I get a message below: Then no matter if I click “Cancel Selection” or “Continue with DBR Amines”, an error message pops out: "You cannot leave basic manager, please correct the issues manually and select OK to continue, cancel to stop ...
Solution: It's caused by the property package. Since DBRAmine was sunset in V11, we are now using Acid gas package as a replacement. To fix this, you can manually modify the inp. file by eliminating the highlighted line: After the converting finished, added it back in HYSYS manually. Key Words PROII to HYSYS Conv...
Problem Statement: When using Aspen Fidelis Reliability Flow Profiles and Pipe Flow Limits, once a pipe tries to go above a Pipe Flow Limit and then drops back to below the Pipe Flow Limit, Fidelis keeps a Unit Max Capacity value and applies it in the future when the Flow Profile continues to be dynamic.
Solution: This issue is present in AFR V11 CP2 (V11.0.2) and has been resolved in AFR V11 CP5 (V11.0.5). Please download the AFR V11 CP5 upgrade package using this link: https://esupport.aspentech.com/apex/S_SoftwareDeliveryDetail?id=a0e4P00000MI8bJQAT Keywords: None References: None
Problem Statement: How to resolve the error “Error starting service AZ370Broker. The service did not start due to a logon failure”?
Solution: When ABE Local Server is installed, by default an account is created to manage the Broker Service. If during the software installation the following message appears the broker service can be started manually right after the installation: The most common cause of this is an invalid password specified for t...
Problem Statement: Model vanishes when it is opened or saved with a very long filename.
Solution: There is a limit to the number of characters for the filename plus path of 240. This is a Windows issue not specific to Aspen Plus since Windows Explorer and other applications such as Notepad have the same issue. Fixed in Version In future releases, there will be a warning dialog upon saving indicating i...
Problem Statement: How to create a Workspace in a Local Server?
Solution: In the article https://esupport.aspentech.com/S_Article?id=000065633 shows how to create the Workspace from Aspen HYSYS and Aspen Plus web client to import PSV data and generate the Datasheets in V11. The next steps are to generate a Workspace with the ABE Administrator. These steps are applicable for V9, V1...
Problem Statement: How to add Boiling Point Curves to a Workbook?
Solution: The following steps explain how to add the Boiling Point Curves values to the Workbook. In Simulation environment, go to Workbook. Under “Workbook” tab, go to Setup. In the Setup page, add a new Workbook Tab. From the list navigate to Utility Objects, select Boiling Point Curves and click OK. ...
Problem Statement: There are cases that we need to control the rate of change of a certain variable in a dynamic simulation. Let’s say, for example, that a controlled heating system has a limitation (or a constraint) that prevents it from heating the fluid at a rate larger than 5°C/min. This type of constraint will imp...
Solution: 1. In the Model Palette, select the Transfer Function Block 2. Define your Process Variable Source (Optional) and your OP Target. 3. In the Parameters tab, configure the Maximum and Minimum Ranges allowed for your PV and OP. 4. Select the Rate Limiter Paramet...
Problem Statement: How to change the date format globally for the datasheet in Datasheet Editor?
Solution: A user can run this query in ABE Explorer by following the instructions. After the user runs the query, any current datasheets or the ones the user wants to issue in the future will have the same format as dd-mmm-yyyy. For setting other different date formats, please refer to the document How to change the sc...
Problem Statement: How to solve connection errors when running APS/MBO with TLS 1.2 enabled?
Solution: APS/MBO do support TLS 1.2 from V8.8 CP6 onwards. TLS 1.2 is supported when connecting to SQL Server in APS/MBO and there should be no impact on products, but correct updates to clients and servers should be applied. For V11 and later versions, APS/MBO are updating to .Net framework 4.7 so that problem with e...
Problem Statement: In real control processes, the response of the control system may not be immediate. To account for such time delays between the controller output signal and the process variable response, the concept of dead time (or time delay) will be used. How to consider this feature in Aspen HYSYS Dynamics?
Solution: s In Aspen HYSYS Dynamics, the time delay must be configured by using a Transfer Block located under the Dynamics & Control session of the Model Palette: Under the Parameters tab, configure the delay parameters (gain and dead time) with the desired values. Note: Do not forget to check t...
Problem Statement: How to add new discipline to ABE?
Solution: Discipline is a way to assign unique access to view and edit specific attributes in Aspen Basic Engineering. This feature allows multiple disciplines to collaborate together while preventing accidental cross-discipline data input. Follow the steps below to assign new discipline to your workspace: 1. Go to yo...
Problem Statement: In Aspen HYSYS each time the user opens a file that contains a custom unit set, this unit set will be stored in the Aspen HYSYS preferences file
Solution: To clean all the custom unit sets that have been stored in Aspen HYSYS please follow these steps: Open File Explorer/Windows Explorer Type %AppData% into the address bar and click enter Navigate to the AspenTech folder With Aspen HYSYS closed, delete the file Aspen HYSYS V#.PRF Keywords: Unit Set, Clean, Stor...
Problem Statement: Aspen HYSYS - OLGA compatibility
Solution: The HYSYS-OLGA Link Extension software enables you to combine an OLGA pipeline transient simulation with a Aspen HYSYS Dynamics process model. The OLGA Link is seamlessly added to the Aspen HYSYS flowsheet just like a standard unit operation. From within Aspen HYSYS, you then connect to an OLGA server, and lo...
Problem Statement: Based on UHX-12.5.9 in the ASME code the equation is: but Aspen Exchanger Design and Rating (EDR) Mechanical is showing: Why the Diameter is equal to the Do or DL instead of showing 4Ap/Cp?
Solution: Aspen EDR Mechanical calculates the Ap (Area enclosed by perimeter) and Cp (Perimeter of the tube layout based on the actual layout) but if for whatever reason the actual layout is not available to calculate this: Aspen EDR Mechanical will use Do. Otherwise it will use DL, the 4Ap/CP­ formula as shown above t...
Problem Statement: How do the RVP definitions in the Cold Properties Utility treat hypothetical components?
Solution: In Aspen HYSYS, the Cold Properties utility includes several methods to estimate the Reid Vapor Pressure as mentioned in the following article: RVP definitions in the Cold Properties Utility. Since the correlations are calculated flashing the fluid, it doesn't ignore hypothetical components. Keywords: Hypothe...
Problem Statement: How to create/modify a Datasheet Template in Datasheet Definer?
Solution: ABE includes several Datasheets templates in its Libraries. A user can modify an existing one or create one from scratch with the Datasheet Definer. To create or modify, follow the next steps: For modifying an existing Datasheet template, go to step 3. For creating a new Datasheet Template, first build a ...
Problem Statement: What is the implication of negative flow in a run?
Solution: The reason the flow rate is negative in a node is because the pipe segments are attached backwards. In Aspen Flare System Analyzer (AFSA), each pipe segment has two connection points: a red connection (upstream) and a blue connection (downstream); AFSA assumes a flow direction from upstream to downstream. So,...
Problem Statement: How to run collect in background using the task scheduler in windows.
Solution: The scheduled task approach can be performed with the following steps: Create a file in notepad and copy the lines below where "C:\collect" is the directory where your collect input files are stored and "exmpl" is the name of your collect input file (the one with no extension). call cd C:\collec...
Problem Statement: In Aspen HYSYS, the user can integrate different heat exchanger with Aspen Exchanger Design and Rating (EDR) to perfrom rigorous calculations. However, in some ocassions this option is not available inside the heat exchanger.
Solution: This could be caused as the Aspen HYSYS and Aspen EDR versions are not the same or Aspen EDR is not properly install in the machine. To solve this please follow these steps: 1. Ensure the default version for both products are the same by running the set version as shown in the following article How to run the...
Problem Statement: How to select language for Aspen Tech Engineering products in V11?
Solution: In version 11, users can select the desired language for Aspen Tech Engineering products. The translation concerns only the interface of the programs Hysys, Aspen Plus, Aspen Properties and does not apply to the Help menu. The following languages are currently available: English Japanese Chinese Russian The d...
Problem Statement: Description of changes to the Aspen PIMS-AO Run Execution Dialog box for V11
Solution: In Aspen PIMS V11, the Run Execution Dialog box has a few changes. Below is a screenshot of the updated dialog. There is now an indication of how many cases have been selected and will run (see red box) The Run Global Optimization option has been moved to the left (see blue box) There is a new feature to aut...
Problem Statement: While generating the code for a Fortran procedure, I get the following error: "No suitable C/C++ compiler was found - compilation aborted"
Solution: To use a Fortran procedure in ACM, the user is required to have the proper version of the Intel Fortran Compiler and Visual Studio installed on their machine. Starting in V7.x and similarly in all 8.x releases, we only support the Intel Fortran compiler, which does not include Visual Studio but it requires ...
Problem Statement: Sometimes you might see the following error message pop up after validating the matrix. What could be the cause of this?
Solution: This is because the user only generated the matrix but didn’t solve it. That’s why PIMS will pass the validation phase but not actually generate any results. Please make sure you have “Solve Matrix” option enabled in the run dialog box. Keywords: None References: None
Problem Statement: IP21 installation hangs up while performing the pre-install steps. Depending on your Windows operating system version and service pack revision, files downloaded from another computer may have their block property set as a preventive measure. The files must be unblocked prior to the AspenONE instal...
Solution: Unblocking of all the files may be achieved when the zip file itself is unblocked before its contents are extracted. If the installation zip file was extracted before the block property was checked then Delete all the AspenONE installation files and folders that were created when the zip file was extracted. ...
Problem Statement: How to Resolve the Data Results Pane Not Showing in the Results Window in PSCP?
Solution: Sometimes after you configure your input Excel tables correctly and run the model, the detailed data pane showing results including Supply, Demand, Inventory, etc doesn’t show up in the Results Window. This data is used to generate DPO_SOLUTION_BREAKOUT tables in the Access database and sometimes we’d like to...
Problem Statement: Sometimes if we open a PIMS model that has text column entries in a different language, we might see the characters changing to strings of messy code instead of regular language. How to avoid this?
Solution: First, make sure the Language Selector option is set to the language that you’d like to display. You can do a search in start for “Language Selector”. Then you’ll need to go to Control Panel -> Clock and Region -> Region. Change everything to the country of that language you are trying to display. Keywords...
Problem Statement: How to Display the Breakout Column Data from the Results Window to show in the Access Database?
Solution: 1. In Program Options in PSCP, go to General -> Check “Use Breakout Columns in Solution Output Tables”. This will make warning message 3160W go away if you are experiencing it. 2. In PSCP, go to Run -> Run Single Case -> Report Option -> Select Breakout Tables option. 3. Run the PSCP model. After it fin...
Problem Statement: Add or remove clients to an existing license reservation file.
Solution: To add or remove users from the reservation file, first, go to the following route on the license server: C:\Program Files (x86)\Common Files\AspenTech Shared\SLM Administration Tools And Execute the file: Wlsgrmgr.exe Once it opens, click on the File option, and then click on Open. Proceed to s...
Problem Statement: I have set up a SQL database for PIMS results - that works fine. However, the tool does not active when selected, either from the PIMS menu or by directly running DbMain.exe. The mouse pointer changes briefly and then nothing else happens. How to get it work?
Solution: The first thing you should check if you have privileges to create the folder "Pims Database Management" under the ProgramData folder. The full path is C:\ProgramData\Aspentech\Pims Database Management. This folder is where the settings for the Pims Database Management tool will be stored. The user will need...
Problem Statement: Unable to install .NET Framework 3.5 on Windows Server 2012. For Windows Server 2012, you need to use "Add or Remove Features" to install .NET Framework but encountered the following error. "Specify an alternate source path" Specifying alternate source via command line failed as welll. dism.exe /o...
Solution: 1.Start the Local Group Policy Editor (gpedit.msc) or Group Policy Management Console(gpmc.msc). 2.Expand Computer Configuration, expand Administrative Templates, and then select System. 3.Open the Specify settings for optional component installation and component repair Group Policy setting, and then select ...
Problem Statement: This knowledgebase solution documents common issues with installation and licenses.
Solution: 1. Ensure ports 5093 and 5094 UDP and TCP are open – The SLM server uses these ports to communicate over the network and without it, can cause installation issues. Often, we see complications with 3rd party software such as Symantec and MacAfee which despite being disabled locally will still operate a domain ...
Problem Statement: License Server can’t be running and the warning 85 is displayed on the event logs
Solution: License server is not running and there are the warning 85 in the Windows application logs as below. “Sentinel RMS License Manager was unable to initialize from the license code” Please check the License file as follows. Windows Start -[All Programs] - [AspenTech] - [AspenSLM] -[AspenOne SLM License Manger] ...
Problem Statement: What is the procedure for requesting an emergency license?
Solution: When your license server is down due to unforeseen circumstances, you can request an emergency license to use while you work on restoring your service: To request an emergency license, following the steps below: 1. Collect the information needed for AspenTech to generate the license: A) License System ...
Problem Statement: What difference between pressure drop calculation methods across the Orifice in Aspen Hydraulics?
Solution: There are several calculation methods for the pressure drop across the Orifice in Aspen Hydraulics: Static Pressure Balance: Assumes no pressure drop. Total Pressure Balance: Ignores frictional pressure drop. Includes accelerational pressure drop. Contraction / Expansion: Model the orifice as a contraction ...
Problem Statement: Is it possible to install Hysys V9.0 and PIMS V10.0 on one machine?
Solution: Different version of Engineering and MSC are not coexist on one machine due to DLL files sharing between them. Key words Different versions, installation, version compatibility, Engineering and MSC Keywords: None References: None
Problem Statement: How do I set my Stream Summary Template as the “default template” for my entire simulation in Aspen Plus?
Solution: In the new stream summary report (or stream results folder), you can set your own template to select only the properties you wish to see. In order to do that, please follow the steps below: 1. Open the simulation whose stream summary you would like to customize. 2. In the stream results summary page,...
Problem Statement: Is there a way to limit how long a license can be checked out?
Solution: AspenTech currently doesn’t provide a mechanism to restrict the usage of licenses to a certain time limit. Based on our experience, AspenTech recommends that such restrictions be managed through internal advisory policies and guidelines. Administrators can use aspenONE SLM License Manager or SLM License Profi...
Problem Statement: Some of the dependent variables are OFF in the DMC controller but the Control Weight column shows a non-zero weight for them. Are these Control Weight values just for display or do they actually have weight in the dynamic move plan calculation when the variables are turned off?
Solution: This control weight value you see is not just for display purposes and it is being used, just not directly within the dynamic move calculation. The weight is used to ensure the ECE tuning across all CVs remain consistent before going into the dynamic move plan. CVs that are Off are not actually included in th...
Problem Statement: Getting A1PE users list from Aspen Process Data Rest through SQLplus
Solution: Attached to this solution there are two text files that will be needed to perform this solution. Please follow the next steps. Download the the text file named “LicenseCall” and put it on Disk C, inside the folder named “temp” so the route to the file will be c:\temp\licensecall. Right click and Edit the file...
Problem Statement: Aspen IP.21 Configuration Excel Add-In can be used to create InfoPlus.21 tags as well as update/create Cim-IO transfer records with reference to the names of items in the Distributed control system. It does this with the assistance of SQLplus procedures stored in the database. KB 134444-2: How are th...
Solution: In detail, the latest procedures should fill in free occurrences in existing transfer records that have the exact required configuration you selected on the configuration panel in Excel. If there are insufficient free occurrences in such existing records then new transfer records will be created. If you do no...
Problem Statement: How to make Oligomer volatile when using equations of state method?
Solution: Equations of State method is using fugacity coefficient for flash calculation so the oligomer is volatile in default. Segment property is used for the calculation of oligomer. But the volatility may not be a correct because this model is purposely designed for high molecular polymer. User need to adjust follo...
Problem Statement: How to make Oligomer volatile when using activity coefficient method?
Solution: Activity Coefficient method is using PLXANT parameter for flash calculation. But the default PLXANT value for polymer (or oligomer) is set to low value to disable the vaporization. And most of polymer activity coefficient method (except PNRTL-IG) is using RK EOS for vapor fugacity calculation. User need to ad...
Problem Statement: Why am I not getting a warning message when my PSV line velocity exceeds the defined limit (set as percentage of sonic velocity)?
Solution: The velocity constraints are applied for single-phase (not homogeneous) line sizing. This line sizing method is only available for vapor and steam orifice sizing; direct integration orifice sizing will always use homogeneous line sizing regardless of the fluid phase. In V10 homogeneous line sizing, we don't c...
Problem Statement: Can I use an input solution generated in a previous case of the same PIMS run? For example, I run cases 1 and 2, but I want an input solution created from case 1 to be the input for case 2.
Solution: PIMS has Table CASE keywords that can be used to do this. Keyword SAVESOL tells PIMS to save an input solution file with the number designated in column B. For example, this entry tells PIMS to create input solution file 1 at the end of solving case 1. Once that input solution file is created, subsequent...
Problem Statement: Aspen Process Explorer and Process Data have been installed on a machine, however when Excel is opened, the Process Data Add-in does not load.
Solution: The error can be caused by: - Problem related to the registration of the new Excel Process Data Add-in. - Problem related to the installation of the VSTO (Visual Studio Tools). - Problem related to the installation of Microsoft Office Interop files. 1. For problems related to the re...
Problem Statement: How to simulate Polyurethane with Aspen Polymers Plus?
Solution: Polyurethanes are a family of polymers produced by pseudocondensation reactions involving diisocyanates. They are characterized by the presence of urethane (~NHCOO~) groups in the polymer backbone. These materials are used to produce adhesives, engineering plastics, and foam sheets. The attachment contains th...
Problem Statement: This example demonstrates how to estimate the solid enthalpy of formation (DHSFRM) and the solid Gibbs free energy of formation (DGSFRM) of a compound to match the temperature of sublimation and the enthalpy of sublimation.
Solution: For components of type "Solid" the reference state is defined through the solid enthalpy of formation (DHSFRM) and the solid Gibbs free energy of formation (DGSFRM). If these properties are not given, they can be estimated from the temperature of fusion/sublimation and the enthalpy of fusion or sublimation, r...
Problem Statement: Using RPlug with countercurrent coolant, Aspen Plus calculates the coolant inlet temperature and overwrites the temperature of the inlet stream. To confirm this calculation, the following message appears in the control panel: INFORMATION WHILE CHECKING INPUT SPECIFICATIONS BLOCK NAME: B2 MODEL NAME: ...
Solution: This is a known problem in Aspen Plus. The Aspen Plus simulator is sequential which means that information is supposed to always flow downstream. However, in some cases such as this one certain blocks push information backwards. The design specification checks that information is sampled that is actually depe...
Problem Statement: How is it possible to decant an aqueous - hydrocarbon mixture using the Free Water approach? Inconsistent temperature profiles occur when decanting a fluid through an adiabatic/isobaric Flash3 model using Vapor-Liquid-FreeWater for the global phase selection. Even though the flash specifications are ...
Solution: Most users intuitively use the Flash3 for decanting. This is a good choice for chemical systems where a rigorous two liquid flash is desired. However, for petroleum mixtures where the shortcut of using Free Water (assuming that the aqueous phase is pure water) is being used, a Flash2 with a Water Decant strea...
Problem Statement: Are there any application simulation examples delivered with Aspen Plus?
Solution: Application examples are delivered with Aspen Plus. These simulations are delivered as backup files with associated output formatting files within the Aspen Plus GUI directory in a sub-directory called app, e.g., C:\Program Files\AspenTech\Aspen Plus xxxx\Gui\App. Fortran files are also included for user subr...
Problem Statement: How is it possible to create non-databank ion, salt and a completely dissociated electrolyte?
Solution: Attached is an example on how to create non-databank ion, salt and a complete dissociated electrolyte. The values for the parameters entered in this example are all fictitious and meant for example only. The minimum number of parameters needed were entered. The parameters for the new salt and ions are entered...
Problem Statement: How to simulate the Claus process
Solution: The textbook version of the Claus Process is: 2 H2S + SO2 -> 3 S + 2 H2O (750 F, 25 psi) (1) User can use RGIBBS or REQUIL to simulate the process. REQUIL would be a good choice if user knows the distribution of different sulfur forms in the product streams so that the equilibrium reactions can be entered ac...
Problem Statement: An Example of Styrene Production from Ethylbenzene - Badger process
Solution: Attached is a rudimentary Aspen Plus model for styrene procuction by the Badger Process. The process information and conditions used in the model are based on Kirk-Othmer "Encyclopedia of Chemical Technology", 3rd Edition, John Wiley & Sons, New York, 1980. Vol 21, page 783. KeyWords: Styrene Ethylbenzene Ba...