Problem Statement: How do I model a piping network where the pipes themselves are known and the source and destination pressures are fixed, but flows are unknown? | Solution: The user must supply initial guesses for flowrates and vary them with design specifications. Solving the design specifications can be difficult, because the variables all interact and because if a flow is set too high, the pipe blocks will have trouble. (Once critical flow is encountered, the downstream press... |
Problem Statement: How can I retrieve Aspen Plus Error Messages with Visual Basic? | Solution: Aspen Plus error messages are stored in a folder called PER_ERROR below the objects which they reference. For example, the messages for the overall simulation are stored as a PER_ERROR collection under Results Summary/Run Status. The PER_ERROR message collection for convergence blocks can be found under the O... |
Problem Statement: What is the EB-Scripts option under Flowsheeting Options in the Aspen Plus 10.1 data browser? | Solution: EB (Equation-based) scripts is meant for users to enter scripts/commands for RT-Opt models. It was added for the RT-Opt 10.0 GUI and should have been removed from the Aspen Plus 10.1 GUI. It is not to be used for Aspen Plus simulations. It will be available in Aspen Plus 11.1 to be used for the dual-execution... |
Problem Statement: Simulation is under specified by 1 when you switch from local to rigorous properties. This occurs with a RADFRAC column in the flowsheet. | Solution: The column has subcooled reflux and liquid distillate and the equation to calculate the liquid mass density at the subcooled conditions is missing from the rigorous properties section of the property sub-model.
Workaround:
Add the missing equation in the Flowsheet Constraints section of the problem
To do thi... |
Problem Statement: How is the melting point of a polymer calculated in Aspen Plus? Is possible to modify it? | Solution: The Metal Transition Temperature (TM) of a polymer is calculated with the Van Krevelen Melt Transition Temperature Correlation (model TM0DVK).
Tm,A = Melt transition temperature for segment type A
nk = Number of occurrences of functional group k in the segment from the segment database or user-specified segme... |
Problem Statement:
New in Economic Suite V10.1 - MS Office 64 bit is supported | Solution:
The V10.1 Economic Suite (Aspen Capital Cost Estimator, Aspen In-Plant Cost Estimator, Aspen Process Economic Analyzer, Activated Economics) now supports MS Office 64 bit applications. Before V10.1 only MS Office 32 bit applications were supported. Starting with V10.1 both MS Office 32 bit and 64 bit appli... |
Problem Statement: Starting in version V7.1 of Aspen InfoPlus.21, 32 Bit; it is possible for Administrators to specify the type of license that is going to be used by a particular database. How to select the License Key Type in Aspen InfoPlus.21? There are four types: Standard - Embedded - Backup - Development.
NOTE: ... | Solution: In order to configure the proper Aspen InfoPlus.21 license type, follow these simple steps:
1. Shut down the database from the InfoPlus.21 Manager
2. From the Administrator tool, right-click on the database name and select "Set License Key Type"
3. Select the appropriate license type and cli... |
Problem Statement: Which switches are available for the AtRunUnattended.exe to perform silent installation | Solution: AspenTech provides a way to automatically deploy AspenTech software to multiple computers to ensure a consistent configuration of the software on all target computers. The aspenONE Installer provides a means to record user inputs using the built-in record option. The output of this recording can then be used ... |
Problem Statement: Why am I not able to locate my current usage reports on the AspenTech Support Center website? | Solution: Access is granted to usage reports based on individual server name and system name combination. If the server name or license system name has changed since the last time you accessed the reports, you will need to send a email request to CustomerCare@aspentech.com and include the new server or system name.
F... |
Problem Statement: How to use the SLM Test tool | Solution: 1. As of Aspen ONE V9, the executable should be at this location:
C:\Program Files (x86) \Common Files\AspenTech Shared\SLM Client Tools
If not, obtain and copy the executable (SLMTest.exe) to a location on the hard drive.
2. Ensure the server is set up via the SLM Configuration Wizard and pointing ... |
Problem Statement: When attempt to connect to the Aspen.Infoplus21_DA.1 of a 64-bit InfoPlus.21 server, the below error message is encountered. | Solution: This issue can be ensuring that the OPC Core Components Redistributable(x64).msi found in
<USB drive>:\aspenONE_V10_MSC_T\aspenonemscdvd\core\OPCCore_x64 is installed. To verify whether it is installed, check whether the folder C:\Program Files\Common Files\OPC Foundation\Bin can be found and that the followi... |
Problem Statement: Unable to find selection for OPC HDA when trying to configure OPC HDA as a data source in Aspen Mtell System Manager. | Solution: In order to configure OPC HDA as a data source for use in Mtell, the following steps need to be performed.
Launch Honeywell PHD Sensor Adapter Configuration.
Enter the server name of the machine which has OPC HDA server installed in textbox beside Server Name in Server Configuration tab.
Enter the OPC HDA ser... |
Problem Statement: After entering the server name and ProgID of OPC HDA server in Honeywell PHD Sensor Adapter Configuration, when testing for connection, below error message is encountered. | Solution: This error is due to the machine installed with Mtell does not have OPC Core Components Redistributable (x64) installed.\
A copy of OPC Core Components Redistributable (x64).msi can be found in <USB drive>:\aspenONE_V10.1_APM\aspenoneapms\core\OPCCore_x64 folder in the USB media.
Keywords: Connection Failed
U... |
Problem Statement: After configuring the adapter to OSIsoft PI for the Plant Historina, when attempting to get data using Quick SPC, error message such as below is encountered.
An error has occurred.","ExceptionMessage":"Method not found: 'Double OSIsoft.AF.Asset.AFValue.ValueAsDouble() | Solution: The Mtell server need to be installed with the PI AF client. Perform the following steps to check on the version of AF SDK installed.
Launch PI System Explorer.
Click on Help | About PI System Explorer....
Look for the line which mentioned AF SDK version.
As per OSIsoft documentation on OSIsoft.AF.Asset.AFVal... |
Problem Statement: "Error: The remote server returned an error: (401) Unauthorized" when launching Aspen Mtell System Manager
Detailed error when browsing http://localhost:80/AspenTech/AspenMtell/InteropServer/MIMOSA/
Error message 401.3: You do not have permission to view this directory or page using the credential... | Solution: This article outlines the instruction to address IIS Error message 401.3: You do not have permission to view this directory or page using the credentials you supplied (access denied due to Access Control Lists). Ask the Web server's administrator to give you access to 'C:\inetpub\wwwroot\AspenTech\AspenMtell\... |
Problem Statement: When launching Mtell View, the below error message is encountered.
Server Error in '/AspenTech/AspenMtell/MtellView' Application.
Could not load type 'System.ServiceModel.Activation.HttpModule' from assembly 'System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089'. | Solution: The error message is due to HTTP Activation not enabled for the .NET Framework. This can be resolved by performing as follow.
Launch Server Manager.
Click on Next button for "Before You Begin" screen.
Click on Next button for "Select installation type" screen leaving selection as "Role-based or feature-based ... |
Problem Statement: When launching aspenONE Credentials, below error message is displayed. | Solution: /Workaround
The Tomcat version might have been upgraded by following knowledge based article "Upgrading Tomcat to address Common Vulnerabilities and Exposures (CVE)".
However, the previous version of Tomcat folder was left in the directory and instead of copying the conf, webapps and appdata directories, th... |
Problem Statement: When issuing SQL query in SQLplus Web Service page, no data is returned even though the same SQL query is working in Aspen SQLplus using the same Windows account as shown in screenshot below from a V8.8 setup without patches applied.
In other version such as V10, Access Denied is returned even thou... | Solution: Aspen InfoPlus.21 is having database security implemented. Although the user had been assigned to a role with permission to read the record as determined in Aspen SQLplus, however, it is due to the authentication settings for SQLplus Web Service in Internet Information Services (IIS) Manager.
This issue can ... |
Problem Statement: What are the advantage and disadvantage of deploying and hosting a single vs. multiple license servers? | Solution: Number of SLM Server(s) Advantage Disadvantage
Single SLM Server · Lower maintenance costs.
· Can host both ENG and MSC Tokens (in separate buckets)
· Single log file for Token report generation.
· Simpler SLM client/server configuration and license file install.
· Greatest License efficiency (Tok... |
Problem Statement: How to configure AFW Security for SQLplus | Solution: 1. Open “AFW Security Manager” as an administrator
2. On the left panel highlight “Roles” à right click
3. Set the name of the “New Role” (create always a role for the Administrator) àOK(Description is optional)
4. Highlight the role à right click à Properties
5. Select "Members" tab à Add à Advanced... |
Problem Statement: After installing Aspen HYSYS, the Ejector/Eductor extension is not shown in the Aspen HYSYS Pallete. It is not listed under Customize / Register Extension / Registered Extensions and it doesn't appear in the installation folder C:\Program Files (x86)\AspenTech\Aspen HYSYS V10.0\Extensions | Solution: The Ejector extension was developed as a collaboration between AspenTech and Transvac Systems as a means of illustrating how liquid-liquid ejectors could be modelled in Aspen HYSYS using known correlations and data at that time (2009) from Transvac Systems. This Automation application was created as an exampl... |
Problem Statement: In some occasions, HYSYS may calculate and transfer to EDR a Vapor Fraction outside of the expected range from 0 to 1:
This will generate an error within EDR and will prevent the model to run.
Workaround
The reason for this behavior is, in most cases, due to a flash calculation problem. There ar... | Solution: Method from “Cubic EOS Analytical Method” to “Numerical Method”, under Properties Environment | Fluid Packages | Set Up
In the future, in case HYSYS calculates a vapor fraction outside the expected range, the values will be capped at the corresponding boundary before being transferred to EDR.
Fixed in ve... |
Problem Statement: Why am I getting input error 1802 when rigorously sizing a Heat Exchanger in Aspen Plus? | Solution: When trying to size a Rigorous Heat Exchanger in Aspen Plus, the following messages in the EDR Browser might pop up:
Input Error 1802: P18: Specific enthalpies for stream 1 do not increase with temperautre, (or only increase by an implausibly small amount). Stream data set number 1, at quality 0.
Even aft... |
Problem Statement: Is there any downside to using the IoLongTagGetDef transfer records, or IoLLTagGetDef transfer records in place of IoGetDef transfer records? | Solution: The long and LL transfer records add additional bytes to the Standard CimIO message. Long transfers add an extra 40 bytes per tag and LL records add 216 bytes per tag. This generally is not a concern and there is no other downside to using Long, or LL transfers for all gets and puts.
Additional details abo... |
Problem Statement: How to enable .NET Framework 3.5.1 within Windows | Solution: This solution provides instructions for installing .NET Framework 3.5.1 for Windows 8/8.1, Windows 10, Windows Server 2012 R2, and Windows Server 2008 R2.
Windows 8/8.1
· Microsoft .NET Framework 3.5 SP1 (3.5.1) in Windows is an optional "Windows Feature" on Windows 8/8.1. To install it, press th... |
Problem Statement: Why can’t I generate Detail Unit Rate Estimating (DURE) reports from Aspen Capital Cost Estimator? | Solution: In order to enable the generation of DURE reports, ACCE performs a check of the available Excel version on the user’s computer, if there is any problem with Excel installation, this can effectively stop ACCE from detecting it and as a result, the option to create these reports becomes grayed out.
If facing ... |
Problem Statement: How to use an Ad-Hoc calculation to calculate the maximum value for multiple tags. | Solution: The Aspen Calc max function allows for 2 tags Max(T1,T2). If the max for additional tags is required the base function can be combined using the following syntax.
2 tags =max(tag1,tag2)
4 tags =max((max(tag1,tag2)),(max(tag3,tag4)))
6 tags =max((max((max(tag1,tag2)),(max(tag3,tag4)))),(max(tag5,tag6... |
Problem Statement: Why is the Description field is grayed out in the Aspen Tag Browser? | Solution: Searching tags by the description field uses Aspen SQLPlus which must be installed on the desktop system and added to the ADSA datasource. Open the ADSA Client Config tool and verify the datasource has the Aspen SQLPlus service component added. Also, check that Aspen SQLPlus is installed on the desktop sys... |
Problem Statement: By default, commuting Aspen Capital Cost Estimator (ACCE) licenses will commute an 8 token license key that is not necessary to run the product. | Solution: Make sure to have this patch installed on the computer that uses ACCE (note: if you are not using the scheduling features of the ACCE, you can go to the next step):
V9: https://esupport.aspentech.com/apex/S_SoftwareDeliveryDetail?id=a0e0B00000DjWEzQAN
V9.1: https://esupport.aspentech.com/apex/S_SoftwareDelive... |
Problem Statement: What is Aspentech's recommendation for organizing Aspen CimIO transfer records? | Solution: When multiple PLC’s are connected to a Aspen CimIO Interface, Aspentech recommends organizing the transfer records by PLC. This configuration may improve the overall stability of the system and make get record maintenance easier. For example; if one PLC is offline the associated transfer record(s) can be tu... |
Problem Statement: Can I change the cost of bulk materials in Aspen Capital Cost Estimator (ACCE) without indexing the Codes of Accounts (COAs)? | Solution: Yes. The user has the option of entering bulks as quoted items, with user-specified prices. Alternatively, the user also has the option of adjusting bulk prices at the component level using the Options | Mat'l / Man-hours % Adj. & Vessel Tracing form.
Keywords: economics, estimate, piping, electrical, inst... |
Problem Statement: The Customized Set of Units (Set1, Set2, Set3) are not being correctly used on the Code Calculation report. | Solution: Internally, the program uses one of (3) sets of units: US Customary, SI or Metric. This is a requirement so all the formulas in the Code Calculation section are congruent (units will match).
For example, for Pressure, there will always be lb/in2, N/mm2 and kgf/mm2, or psi, MPa and Kgf/mm2.
For customized Se... |
Problem Statement: Attached is an example of a User Property Set to calculate the total Gibbs free energy of a stream | Solution: Attached is an example of a User Property Set to calculate the total Gibbs free energy of a stream. A Fortran compiler is needed to compile and run this example.
C
C
C Purpose: This routine is an example of a user-defined property
C that can be used within an ASPEN PLUS property set.
C... |
Problem Statement: Are the Setting Plans and Tubesheet Layouts displayed for non-TEMA type exchangers? | Solution: Both the Multitube Hairpin (M-type shell) and the Double Pipe (D-type shell) type exchangers are non TEMA type shells and thus are NOT supported for Setting Plans. As for the Tubesheet Layouts, only the layout for the M-type exchanger is displayed on EDR Shell & Tube Thermal.
If you try to change the model f... |
Problem Statement: If you have been given a SQL Server database file (filename.bak) and need to restore the database. | Solution: Please use below example script (modify where necessary):
USE master;
GO
ALTER DATABASE MTell_Test SET SINGLE_USER WITH ROLLBACK IMMEDIATE;
RESTORE DATABASE MTell_Test FROM DISK = 'C:\DB_backup\MtellSuite.bak' WITH REPLACE;
ALTER DATABASE MTell_Test SET MULTI_USER;
Keywords: None
References: None |
Problem Statement: What needs to be considered when performing upgrade or maintenance work on SLM License Server? | Solution: The process to follow:
1 – Local I.T. to perform full back up of physical SLM License Server or take snapshot of server if it is a virtual server
2 – Work to be done out of hours
3 – If applying a Microsoft patch or Fix to the SLM License server
4 – Not all Microsoft Patches have been tested by AspenTech so ... |
Problem Statement: Why are the temperature ranges I specify when importing an exchanger to EDR not working? | Solution: When importing a heat exchanger from an Aspen Plus simulation to Aspen EDR, the following window shows up:
Said window displays a table with editable values, so you can try and re-specify Lower and Upper Temperatures on each Pressure set, after which you can click on Import. Once the heat exchanger has be... |
Problem Statement: Why is there a “Stage 0” in a vacuum column? | Solution: In vacuum columns, the 1_Main Tower section shows specs for Stage 0 . The pressure specification shown for this so called "Stage 0" is the Vacuum Overhead Product Pressure (which is indeed, vapor).
Going inside the Column Environment may be more insightful. Stage 0 is merely representing the Prod P pre... |
Problem Statement: Why is EDR not giving tube velocities and displaying Error 5 when running? | Solution:
The following error may be encountered when running a Shell & Tube exchanger in EDR:
This occurs because EDR cannot detect overlapping tube passes and it can obtain a tube layout exchanger design with this characteristic:
The algorithm will be changed so that it kept better track of how many ro... |
Problem Statement: Is there a web version of the Aspen Golden Batch Profile Monitoring Plot? | Solution: Yes, there is a web version of the Aspen Golden Batch Profile Monitoring Plot. You can use aspenONE Process Explorer (A1PE) to create such a plot.
Open A1PE, navigate to Process Explorer, click the + button and select the Golden Profile on the Event Plots tab.
Keywords: None
References: None |
Problem Statement: What does Warning 1917 mean on Exchanger Design and Rating? | Solution:
The message (on EDR) Results Warning 1917 states: "In a reflux condenser the condensing range was 32.09F. Your input or calculated temperature-enthalpy relationship may not be valid with this condensing range and counter-current vapor-liquid flow."
This message basically says that the accuracy of the E... |
Problem Statement: How to include testing hours in ACCE N option | Solution: The attached document explais changes in N-Option for painting costs and coats of painting per component and pipe, instrument and electrical testing for areas.
Keywords: N-Option, Paint, AIPCE, ACCE
References: None |
Problem Statement: Sorry, Error Adding Aspen Calc server ‘SERVERNAME’
This error occurs when using a web browser on the same computer where the Aspen Calc web application is running (in the Microsoft Internet Information Service (IIS), and Enhanced Protection is enabled for the internet zone where the Aspen Calc web ap... | Solution: This error occurs because when using web browsers like Microsoft Internet Explorer, they are not allowed to invoke operations in IIS (on the same computer) that involve writing to objects like files or registry keys. This is part of the Enhanced Protection feature added to IE a while back. Apparently, actions... |
Problem Statement: What does Warning 1336 mean in EDR? | Solution: When working with a Shell & Tube model in Exchanger Design and Rating, an Operation Warning 1336 may show up.
"Operation Warning 1336: The optimum design to minimize surface area (or capital cost) results in a tight baffle pitch with a low crossflow fraction. Consider trying alternative designs with a larger... |
Problem Statement: How to add a new craft in the construction workforce project basis | Solution: Under Construction Workforce | Wage Rates display the Craft Wage Rates. Review the Craft code list and pick a number to avoid repeating the same code for the new craft. For example, craft code 55 doesn’t exist in the list below so let’s use that number.
Move to Craft Names and include the new code (i.e. 55) ... |
Problem Statement: Sorry, Aspen Calc server ‘SERVERNAME’ is not available
This error occurs when the web application fails to make a successful DCOM connection to a Calculation Scheduler either locally or remotely. This is typically due to insufficient DCOM access permissions on the computer where the Calculation Sched... | Solution: Aspen Calc Web Application Configuration
Aspen Calc’s web application allows users to connect to the Calculation Scheduler service on computers throughout a network. Once connected, users can manage the Calculation Scheduler using a web user interface instead of having to install the Aspen Calc thick client ... |
Problem Statement: Why do I see the Input Warning 1869: “The specified or implied heat load is above the maximum plausible value. It has been scaled by x.xx, to give this value as a first estimate for the Simulation calculation”? How do I prevent it? | Solution: When working on Simulation mode, you have to specify the exchanger geometry and process information defining a first estimate of the duty. However, if the specified/estimated heat load for either the hot/cold streams is above the largest possible heat load based on your inlet conditions, Aspen EDR will escala... |
Problem Statement: On the HTFS Resonance Analysis table, when tubes report a Turbulent Buffeting ratio (Ft/Fn) between 0.8 to 1.2, they are marked with an asterisk, as possible vibration problem. However, no Turbulent buffeting amplitude is reported. What is the reason for this? | Solution: When the natural frequency is high (i.e. grater than 88Hz) it yields zero amplitude according to the TEMA method calculation for Turbulent buffeting amplitude. When using the HTFS method, Aspen EDR does not report the zero amplitude value as it is not physical.
In the same way, the Resonance Analysis only rep... |
Problem Statement: When opening the MOC (Manufacturing Operations Control) you may get the message "Server watchdog Condition Detected" in the MOC Client? | Solution: This message will appear by default every 60 seconds if the Apache tomcat server is not running or cannot be reached. To resolve this issue check the following:
Check the server to ensure that the Apache Tomcat service is running.
On the server check the flags.m2r.cfg for the port number and ensure this is op... |
Problem Statement: What does the “Note 866: Designer elected to apply ASME VIII Div 1 UCS-68(c) MDMT temperature reduction” means? | Solution: Minimum Design Metal Temperatures (MDMT) are set based upon the lowest operating temperature the pressure vessel will encounter. Material specifications, impacting testing, and PWHT should be selected that will meet the MDMT requirements per the applicable design construction code.
The Note 866 means you have... |
Problem Statement: How PIMS AO calculates Nonlinear Ratio | Solution: PIMS AO uses nonlinearity ratio to represent the accuracy of the predicted change in the equation. If the equation is linear, the nonlinearity ratio will be 1.0, otherwise it indicates how nonlinear it is. A negative nonlinearity ratio indicates movement of variable value in the opposite direction. And a larg... |
Problem Statement: How can I determine which license keys are being used by an aspenONE V8.x application? | Solution: In versions prior to V8.0, this was displayed by selecting Help from the toolbar and then select About. In V8.0 and higher, this functionality is accomplished by selected to File, About, and then Licensing Information.
After clicking the License Information button, a display will show the license key(s) c... |
Problem Statement: Is there a way to change the nozzle locations for a Shell and Tube exchanger? | Solution:
You can set the locations for the nozzles in the EDR model. Just go to Exchanger Geometry | Nozzles | Nozzle Orientation and choose from the dropdown options for either Shell or Tube Side Nozzles.
Just be aware the nozzle orientation may not be acceptable by EDR. If you select a non-acceptable location ... |
Problem Statement: How to report Flooding Velocity for knockback condensers in EDR? | Solution: Currently, the program provides messages if the inlet velocity is close to the flooding velocity based on the following criteria:
Warning message if inlet velocity exceeds flooding velocity
Warning message if inlet velocity is 80% of the flooding velocity
Advisory message if inlet velocity is 50% of the flood... |
Problem Statement: How to model a Plate Fin Kettle exchanger in Aspen Exchanger Design and Rating? | Solution: The program Aspen Plate Fin Exchanger allows modelling these types of exchangers. The only calculation mode available is Stream by Stream simulation which uses the common wall temperature assumption. Other calculation modes such as Layer by Layer simulation, Rating and Design are not available for these types... |
Problem Statement: Where are the logs for Aspen Cloud Connect? | Solution: The logs for Aspen Cloud Connect are located in folder C:\Program Files\AspenTech\Aspen Connect\
ToolKit logs:
C:\Program Files\AspenTech\Aspen Connect\Toolkit\Logs
DataCollector logs:
C:\Program Files\AspenTech\Aspen Connect\Cloud Connect\DataCollector\Logs
DataSender logs:
C:\Program Files\AspenTech\A... |
Problem Statement: What inputs affect the pricing of a flow meter? I have made quite a few changes to my piping rates, viscosity, and density, line/loop specs etc. but the flow meter price stays the same. | Solution: Flow instruments are added at a unit cost and are independent of the piping rates, viscosity, and density, line/loop specs etc. You can view and modify the unit prices using the Aspen Capital Cost Estimator tool using the Unit Rate estimating feature. Attached is a screenshot showing the unit price for the fl... |
Problem Statement: I am getting an ERROR message when I run my scenario estimate. What does ERROR> 'PC - 4' CABLE TYPE TO OPERATOR CENTER IS INCORRECT mean and how do I fix it? | Solution: The PC-4 ERROR to refers an ERROR in the Process Control section of the Project Basis. The origin of the problem is the Control Center definintion.
If M is the option selected in the Cable type to Operator Center field, while DDCTL (Digital) is the specified Control Center type, this ERROR will occur.
The... |
Problem Statement: Why do I see the “Input Warning 1061: Based on the inlet and outlet conditions the cold stream is a liquid, but two-phase properties have been specified. The program may apply subcooled boiling calculations”? | Solution: Suppose the cold stream outlet temperature is just below the bubble point (so really the cold stream is single-phase liquid). It is quite possible that at some point along the tube, the local wall temperature may be above the bubble point, that may cause the fluid to locally boil, but later may re-condensate ... |
Problem Statement: The attached document describes how to set Property Table values using EDR’s Automation (COM) interface. This document also provides some related information that is useful when using EDR’s COM interface from Visual Basic or VBA in Microsoft Excel. Also see the section “The Aspen EDR .NET Automation ... | Solution: This guide covers:
How to identify variables
How to
Keywords: EDR, VBA, COM Interface, Properties, Variables, Automation.
References: the EDR COM interface
EDR COM interface
Setting Properties |
Problem Statement: When estimating the cost of a project that includes a HDPE High Density Polyethylene fusion bonded plant bulk pipe an error message saying SDR NOT AVAILABLE is thrown. Why is this happening? | Solution: The reason for the error message is due to the standard pipe availability recognized by Aspen Economic Evaluation for pipe diameter and SDR number.
For example, if a HDPE pipe with an SDR of 7 is defined with a 30 inch inner diameter (ID) pipe you will, the following message:
ERROR> 'PIP- 88' REQUESTE... |
Problem Statement: What does "Operation Warning 1920: Flame height is too large for the firebox" means, and how do I prevent it? | Solution: The flame length is used to determine the heat release pattern within the firebox. You can either specify a value, or leave it blank, to let the program determine a typical value given the fuel and burners specified. As the Operational Warning states, the flame height is too large for the Firebox; in Aspen Fi... |
Problem Statement: Why if I use EDR inside HYSYS to size a heat exchanger, the resulting heat exchanger has different geometry than the one I would get if I use EDR independently and import the properties from HYSYS? | Solution: These differences are probably caused by properties used during the design process, and are usually observed when there are two liquid phases present in at least one of the streams.
When EDR is used standalone and a HYSYS file is imported (containing two liquid phases in one of the streams), both liquid phas... |
Problem Statement: Security Alert: Information about Meltdown and Spectre fixes and AspenTech software | Solution: AspenTech is aware of recently disclosed research regarding side-channel analysis of speculative execution on modern computer processors. Several different vulnerabilities have been identified, which have been named Meltdown and Spectre by the researchers and are tracked as CVE-2017-5715, CVE-2017-5753, and C... |
Problem Statement: What does "Operation Warning 1918: Stack exit temperature is below the dew-point" mean, and how do I prevent it? | Solution: On gas fired heaters, the dew point of the flue gas is around 330 K (57°C) and the condensate is water made slightly acidic by dissolved CO2 and NOx. With sulfur-laden fuels a more serious problem arises in that dilute sulfuric acid is formed. The presence of this acid not only increases corrosion but raises ... |
Problem Statement: How can Aspen Plus Data Fit data be retrieved via Visual Basic COM? | Solution: An example, written in Visual Basic for Applications (VBA) in Excel97, on how to access data within an Aspen Plus Data Fit data set is attached. The Visual Basic code in this example can also be used in standalone Visual Basic projects.
The data is triple indexed. The first index is traditional. The second in... |
Problem Statement: Example of a User Property Set to calculate the solids concentration in a slurry based on g/L or wt. %
Both Aspen Plus 9 and 10 Fortran routines are attached. | Solution: C--THIS FILE HAS BEEN CONVERTED BY AP9TO10----
C Purpose: This routine is an example of a user-defined property
C that can be used within an ASPEN PLUS property set.
c
C Product
C Release: Release 10 of ASPEN PLUS
C
C Supporting
C Files: TESTSOL.INP
C
C Usage
C ... |
Problem Statement: In the Aspen Cim-IO Interface world, an ''Unsolicited'' request means that you would like the value sent :
from the Aspen Cim-IO Server,
to the CIM-IO Client (InfoPlus.21 Server),
ONLY when the value has changed (or changed by a certain amount).
In this case, what is the reason, meaning and impact of... | Solution: If you look in the Aspen Cim-IO User''s Guide for the description of IO_FREQUENCY for an IoUnsolDef record, you will see a lengthy explanation of the impact of using positive or negative numbers in that field.
The first thing to realize is that every Cim-IO Interface is unique and their capabilities depend on... |
Problem Statement: How to limit the maximum number of Tokens can be commuted from SLM License Server | Solution: A user can commute any number of tokens from a SLM License Server using the SLMCommute tool. This article will help you to add a token percentage cap on the SLM Server so that all the tokens will not be used by commuting users.
1. Login to the SLM License Server
2. Open the Environment Variables fro... |
Problem Statement: What are all the different worksheet with EIU Template and its purpose? | Solution: The different worksheets specify Settings, crude tank volume & properties, crude receipt events info, component run down info. & assay info.
Additionally, specifying for each sheet please refer below:
Worksheet names associated with data you are importing, must match the following:
Worksheet Name Descript... |
Problem Statement: What type of pressure Aspen Exchanger Design & Rating (EDR) uses? | Solution: All the pressures in Aspen EDR are absolute, unless it is specified otherwise. This is to maintain consistency with the literature references, in where is well accepted that all pressure is absolute, unless it is specified as gauge/relative.
Note: the specified design pressures used in the mechanical design... |
Problem Statement: Why do I see the Input Warning 1862: "In absence of adequate information to determine heat loads, it has been assumed that stream 1 condenses completely (…)”? How do I prevent it? | Solution: When working on Simulation mode, you have to specify the exchanger geometry and process information defining a first estimate of the duty. However, if the program does not have enough information to estimate this initial duty (for example, if you only defined the inlet conditions and flow rates of the hot and... |
Problem Statement: This article explains what the messages "The timestamp in one of the cache.dat files does not match that of the snapshot." and "Performing history synchronization." found in TSK_DBCLOCK.OUT mean. | Solution: Aspen InfoPlus.21 points are records that store history. A point has one or more history repeat areas. History repeat areas hold the most recent historical values for points. For example, a record defined by IP_AnalogDef has a history repeat area named IP_#_OF_TREND_VALUES which contains the most recent co... |
Problem Statement: How do I add a new sensor to an existing Equipment Set? | Solution: To add a new sensor role to an existing equipment set please follow the steps below.
1. Log into Aspen Mtell Agent Builder and click on the Machine Learning tab
2. Highlight the equipment set you would like to add a new sensor role to and click on the Sensor Roles tab
3. Click on the Add.. button
4. On t... |
Problem Statement: After creating a new KPI, the calculated values and the display on the right side of the Plot Area do not appear | Solution: If the KPI doesn’t bring any data but the tag is collecting information correctly, open InfoPlus.21 Administrator and look for the KPI created. On the fix area look for the IP_CONFIG_STATUS it must be on OK.
If is empty this means that the TSK_KPI has not been created or is not running.
If it’s not runni... |
Problem Statement: Why should I avoid to use COA300, 400 and X00s for accountings? | Solution: ACCE uses these COA as heading or title for sub-COA, so some of reports cannot report the cost rightly.
We don't recommend to use these COA for specific accumulation costs.
Keyword
COA, ACCE, Account
Keywords: None
References: None |
Problem Statement: What is the error message "Analysis failed. The correlation matrix is not a Positive Definite matrix." during the risk analysis? | Solution: ACCE uses the Monte-Carlo method which requires Positive definite matrix.
If user correlation matrix does not satisfy positive definite, ACCE will give you an error message as above.
About the definition of positive definite matrix, please see the below link.
https://en.wikipedia.org/wiki/Definiteness_of_a_... |
Problem Statement: How can I delete many tags at once? | Solution: Note: Before executing the query attached to this solution, save a copy of the database to a snapshot that can be used to restore the database in case the query yields unexpected results.
Attached to this solution is a query named DeleteTags.txt. Copy the contents of the text file into the Aspen SQLplus Qu... |
Problem Statement: How can I convert UNIX Epoch Time (i.e. number of seconds since 01-JAN-1970) to Aspen InfoPlus.21 format? | Solution: Attached to this solution is a file named UnixEpochTimeToIP21Time.txt. Copy the contents of this file to the Aspen SQLplus query writer and save the query as a record defined by ProcedureDef named UnixEpochTimeToIP21Time.
UnixEpochTimeToIP21Time has one calling parameter:
UnixEpochTime - Integer UNIX Epoch T... |
Problem Statement: How do I clone pure components in Aspen HYSYS? | Solution: Pure components in the HYSYS library can be cloned and the the properties can be modified. For example cloning of pure water can be done to represent salt water in the process.
Follow the steps given below to clone a library component:
1. Open the HYSYS case and Enter the properties page
2. Display the comp... |
Problem Statement: How can I display an integer value in Aspen InfoPlus.21 as binary? | Solution: Use the message display format code "UB 32" to display an integer value as binary.
Key Words
Binary
UB32
UB 32
Keywords: None
References: None |
Problem Statement: How to improve the publishing speed for a large SQL database in APS by cleaning up the publishing tables? | Solution: In V11, there is a new CONFIG keyword that users can set in order to potentially increase the publishing performance.
The keyword is SQLSERVER_DELETE_RESULT_TBL_W_TMPTBL. This can be set to Y in table CONFIG.
SQLSERVER_DELETE_RESULT_TBL_W_TMPTBL keyword has been added to improve publishing speed when working... |
Problem Statement: Encountered "Win32 error 1314" message when starting up the Aspen CIM-IO Manager service. Here is the sample error logged in the CIMIO_MSG.LOG file:
Logged by CIMIOManager on node xxxx: Win32 error 1314 logging on as xxxx for server xxxx
Logged by CIMIOManager on node xxxx: CIMIO_MGMT_SERVER_LOGON, ... | Solution: In order to resolve this issue, the local security policies need to be updated. Specifically, the account used to start CIM-IO Manager need to be added to the Local Policies for:
Act as part of the operating system
Log on as a batch job
Log on as a Service
Replace a process level token
Go into Control Panel ... |
Problem Statement: Having built a report on the Aspen SQLplus reporting website, you set the report format to Excel and test it interactively. Excel file is seen to be created successfully. You find when switching it to be automated, NO Excel file is generated when the report is activated by the trigger event. If you s... | Solution: Non-interactive use of server side office automation can be made to work but certain folders are expected to exist.
You need to make some changes to the Aspen InfoPlus.21 server / web server.
1. Use Windows Explorer to create two folders: (replace SysWOW64 with System32 depending on your use of x86 or x64 ... |
Problem Statement: In ACCE, how can I know how many piles there are for the building? | Solution: For buildings added, based on its rule, selection of foundation type for building will not affect its cost, this is for information only, so ACCE will not calculate the pile quantities.
But user can control pile specification in Area level civil specs form.
And then, adding number of piles manually for th... |
Problem Statement: Table Settings "FIXBAL" is not working correctly when define in case file and cause reporting problem in Full | Solution: .
This is a known issue in PIMS AO and occurring in PIMS V10 CP4.
Description:
User might want to set FIXBAL in Table Settings for certain case in case file. For this example, define in Case 8.
Run the case in AO and check on xmps000008.Xlp file. Row Type shown as LE instead of EQ.
We can also notice th... |
Problem Statement: Which property method should I use, when modeling Sour Water systems in Aspen HYSYS V11.0? | Solution: Aspen HYSYS V11 features a new Sour Water property package, which models the removal of H2S, NH3, and other contaminants from water.
Advantages of using Sour Water Property Package are:
Rigorous rate-based distillation
Enables the modeling of both reaction kinetics & mass transfer
Auto-generated Reaction Ch... |
Problem Statement: I notice that my strip chart does not display all the data that should have been stored. Why is this? | Solution: There are three main reasons why the strip chart would not be displaying data that you believe should have been recorded:
1. You have elapsed the maximum number of points available for the logger, i.e. the logger is now 'forgetting' the oldest points.
To solve this increase the number of logger points and/or... |
Problem Statement: License Commuting Troubleshooting Guide | Solution: This article contains a list of KB to help you troubleshoot SLM Commute issues:
Getting Error 77 while commuting a license
How do I prevent SLM Error 84 when commuting a license?
Are administrative privileges required to setup commuting on a client machine?
What information should be provided to AspenTech... |
Problem Statement: This knowledge base article describes how to limit the number of days for which a license can be commuted by an end user. The SLM Commute tool can commute the license keys for a maximum of 30 days, but the 30 day limit can be reduced. | Solution: 1. To launch Windows Registry Editor, open Windows start menu and type "regedit" into the search box, and then click the result "regedit"
NOTE: To make edits in the registry, you will need Administrative privileges.
2. Go to HKEY_LOCAL_MACHINE\SOFTWARE\Aspentech\SLM\Configuration
3. Right click on the the o... |
Problem Statement: How do I configure CIMIOOPCPUTLISTFREQUENCYINSECS for Aspen Cim-IO for OPC when using Aspen DMCplus controllers? | Solution: 1. Shutdown Aspen InfoPlus.21, Aspen DMCplus, or any other Aspen or third-party applications that use Cim-IO. Stop Aspen Cim-IO Manager and Aspen Cim-IO for OPC Interface services. Stop any other third-party services that use Aspen Cim-IO. Stop all Cim-IO processes (e.g. AsyncDlgp) if still running.
2. ... |
Problem Statement: Joule-Thomson-Coefficient-Calculator-with-ACM | Solution: ACM exported model to Aspen Plus to be used for JT coefficient calculation.
.
User need to install .ATMLZ file to operate the calculation. JT coefficient will be calculated as per the inlet stream information.
These files are compatible with V11.
Original code in ACM
Model JTCOEFF
Inlet as input molefra... |
Problem Statement: How do I install a license dongle? | Solution: Before connecting the dongle to the USB port, you will need to install the dongle drivers so Windows will detect the dongle.
You can either download the dongle driver through the View Attachments link below or install it from the aspenONE media.
To install the dongle drivers, follow these steps:
1) You wil... |
Problem Statement: Starting Aspen InfoPlus.21 results in loss of recent trend data after applying V11.0 CP1 ("Aspen MES V11 CP1 (V11.0.1) Cumulative Patches - November 2019").
This problem only occurs after applying V11.0 CP1.
When historical recordings are made, values are first written to the history repeat area ... | Solution: After installing "Aspen MES V11 CP1 (V11.0.1) Cumulative Patches - November 2019 ", you must install "Aspen_InfoPlus21_V11.0.1_ECR_00519220 for InfoPlus.21 V11.0.1 servers (32 or 64 bit)."
Key Words
Keywords: None
References: None |
Problem Statement: Why are the ASTM D86 results empty for a gas stream? | Solution: The results of D86 are empty if most compositions in this stream are light end components. In such a case, D86 curve is not applicable to characterize this stream. The D86 curve is converted from TBP curve by API 3A11 method. Users can search this method via API manual. You need the TBP curve in the valid r... |
Problem Statement: A and V frames are usually used for condensing duties where good condensate drainage is obtained. However, they can be used for single-phase cooling where plot area is at a premium. | Solution: When modeling an A or V frame, the following steps need to be followed:
- Select the Rating/Checking or the Design calculation mode (Input\Problem Definition\Application Options)
- On the Exchanger Geometry|Geometry Summary form for the Exchanger frame type, select 'A or V frame'
- Next, in the Fan confi... |
Problem Statement: Upon installation of Aspen IP.21 Process Browser (formerly Web.21), SUN Java is also installed. After this, systems may get the version of Java updated, and may experience problems when using Aspen InfoPlus.21 Process Browser. How to recover from this? | Solution: Customers have reported various degrees of success when using newer versions of Java in their system, but the recommendation is to always use the one supplied with the product, as this is the only one it was tested on.
In all cases, the product installation guide and release notes should always be consulted... |
Problem Statement: The functionality of graphics created in the Aspen IP.21 Browser Graphic Studio can be extended through the use of Java Script. Scripting is performed as a result of events, such as the onClick or onEnter event for a button or data field. As long as the syntax rules of Java Script are followed, users... | Solution: JAVA SCRIPT EVALUATION PAGE:
A Java Script evaluation page is available in each Aspen Graphic Studio installation. In the
C:\Program Files (x86)\AspenTech\Web21GraphicStudio\Tools
directory, there is a file called JSEval.htm. If you open this file in Internet Explorer, it offers a window from which you can ty... |
Problem Statement: Animation is a set of graphical states that define how the appearance of an object changes, depending on specified conditions. Aspen IP.21 Browser Graphic Studio allows custom animation schemes to be saved and reused within a project.
This Knowledge Base article answers the following question:
... | Solution: The schemes are saved in the project file (.prx) located in the C:\Users\<username>\Documents\Web21Graphics directory.
Keywords:
References: None |
Problem Statement: Which System, User, and Application Configuration Files should be Saved, Backed Up,
and/or Transferred when Upgrading to the aspenONE V11.0 Release on MES Web Servers
on which aspenONE Process Explorer is installed. | Solution: The KB Article content documented below is intended to help you identify the important A1PE (aspenONE Process Explorer)
Web Server Installation and/or Application and User Specific Files that need to be Saved and Backed Up during Upgrades,
and/or Transferred to the New Server / Client Machines when Migrating ... |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.