question stringlengths 19 6.88k | answer stringlengths 38 33.3k |
|---|---|
Problem Statement: Customers who do not have a token license agreement should not install the 64-bit version of Aspen software. | Solution: Aspen InfoPlus.21 (IP.21) release version 8.5 is available both in the 32-bit and 64-bit version. The V8.5 installation media, both DVD 2 and DVD 2T, lets you install either 32-bit InfoPlus.21 or 64-bit InfoPlus.21. However, the 64-bit version of Aspen InfoPlus.21 is only available to token customers. As ther... |
Problem Statement: How many user databanks can be added? | Solution: There was a limit of 30 databanks before version 12. In 12.1.3 and higher, there is a limit of 200.
Fixed in Version
12.1.3 and 2004 and higher
Keywords: user databank
References: None |
Problem Statement: When opening an .apw file, Aspen Plus gets the components mixed up (i.e., it starts to use physical property parameters for the wrong components). If an .inp file is exported, I get this for components:
COMPONENTS
N2 C10H16-D2 /
ETHANOL C6H12O-E1 /
PROPANOL C5H8O-D1 /
WATER C5H4O2 /
P-XYLENE C8H10-... | Solution: This problem occurs when an old .apw file is used after the user interface has been customized to add a user or inhouse databank. When the user interface is customized, the system definition file (recdef) will change. The recdef contains pointers to the components which will point to new places after the cust... |
Problem Statement: Where are the TBS files used to customize Aspen Plus and Aspen Properties?
In the Aspen Plus System Management Guide, it states that the TBS tables are stored in a compressed file format. To decompress the source data, use the extr_tbs command from the Aspen Physical Property System utilities direc... | Solution: Go to the Engine\utl (e.g. C:\Program Files\AspenTech\AprSystem 2004.1\Engine\utl) directory and run the extr_tbs.exe file.
Fixed in Version
CQ00228210: The documentation has been corrected for version 2006.
Keywords: lcd
table building system
References: None |
Problem Statement: Aspen Plus V8.4 now thinks that Equation Oriented (EO) input is incomplete if the physical type is not specified. Earlier versions accepted EO Input without a physical type. | Solution: Starting in V8.4, the EO Input form now requires physical type and units to be specified for each variable. This ensures that the value and bounds specifications are interpreted correctly if the global unit set is changed. It was always possible to specify these units, but it was not required, so simulations ... |
Problem Statement: Files with the .scr extension which Windows 7 takes to be screensaver files are impossible to delete. Therefore, if Aspen Plus crashes, I'm left with a file I can't delete. In addition, a file FORT.32 has been created in the local working directory. | Solution: The inability to delete a .scr file (this is the accounting file unit 32) is caused by use of anti-virus software for Windows, McAfee VirusScan Enterprise. Apparently the software tries to protect the system registry by preventing the user (even an administrator) from moving or deleting a .scr file. Temporar... |
Problem Statement: Is it possible to specify the reaction in the condenser and reflux drum?  | Solution: Reactions in the reflux drum and condenser cannot be modeled in Aspen Batch Modeler.
This is not as clear as you might expect when selecting option "reaction occur in all stages" that condenser and the reflux drum (if available in the column) will be also taken into account.
When specifying in the simulation ... |
Problem Statement: The current methodology of optimizer tuning faces several challenges:
· Generally the preferred optimization direction of variables is known. LP tuning is then developed to match these objectives
· Cost factors are not readily available and therefore are set by trial and error to achi... | Solution: Smart Tune is a new multi-objective, steady-state solver algorithm that sequentially optimizes Manipulated Variables (MVs) based on priorities available in Aspen DMC3 software. Smart Tune allows the user to:
· Specify controller objectives using priorities instead of LP cost factors
· Utilize ... |
Problem Statement: Aspen Desktop Applications installation procedure in Japanese.
日本語版Aspen Desktop Applications 設置手順書です。 | Solution: See Attached.
添付設置手順書を参照下さい。
Keywords: Aspen Process Explorer, Japanese, 日本文
References: None |
Problem Statement: When I try to import an .mtl file by going to Data | Pure Components | Import Material... | Select Source, the Source Materials pane is empty. How can I resolve this? | Solution: Every .mtl file is associated with a .prj file. This issue occurs when the .prj and .mtl files were created in a version earlier than V8.8. There is an upward compatibility issue that causes the .mtl file to be unreadable when the user imports it into V8.8.
The workaround is to open .prj file associated with ... |
Problem Statement: How do I manually install the Aspen Cim-IO for OPC service? | Solution: There are times when the Aspen CIMIO for OPC either does not get installed with the usual installation or the service has disappeared from services panel.
This article describes the procedure to manually install Aspen Cim-IO for OPC.
1. Open DOS prompt (cmd) using “run as admin�.
2. Speci... |
Problem Statement: What do I do with environment Variable LSHOST when there is more than one server? | Solution: The LSHost environment variable is used to tell the application to search for one or more license servers. When using multiple server names on the same line you need to separate the names, in both the environment variable string and ?lshost? file, with a colon (:).
When this variable is set, the application... |
Problem Statement: Does Aspen Shell & Tube Mechanical have a mechanical design method based on China GB code? | Solution: Shell&Tube Mechanical does not have the Chinese GB code. ASME code is accepted in China by many users because the GB code is based on the ASME code and TEMA.
The mechanical design methods available in Shell&Tube Mechanical are:
ASME (American)
CODAP (French)
AD-Merkblatter (German)
EN 13445 (European)
Keywor... |
Problem Statement: Can I add stiffening rings to pressure vessels in Aspen Shell & Tube Mechanical? | Solution: Yes, the option is available. The first thing needed is to setup the pressure vessel option under Problem Definition|Description|Headings/Applications.
Then to see the stiffening rings option navigate to Exchanger Geometry|Shell|Shell Cylinder. The program will add stiffening rings automatically if option is ... |
Problem Statement: Opening the Aspen AFW Security Manager program causes the error:
Could not connect to AFW Security Server "system_name" via HTTP with the URL:
http://<system_name>/AspenTech/AFW/Security/pfwauthz.aspx
Opening the page:
http://<system_name>/AspenTech/AFW/Security/pfwauthz.aspx
in Internet Expl... | Solution: Verify the Aspen Security Pool in Internet Information Services (IIS) Manager is configured to use .NET CLR version 4.0.30319.
Keywords: AFW Security Manager, connect, pfwauthz.aspx
References: None |
Problem Statement: How can we limit the percentage of a crude in the mix of crudes fed to a logical crude unit in Aspen PIMS? | Solution: Several methods are available to limit the percentage of a crude in a mixture:
? Method 1: Create a deferred cut for the crude pool and use PROCLIM to limit the target crude percentage
? Method 2: Define constraint rows in Tables ASSAYS and ROWS
Method 1: Create a deferred cut for the crude ... |
Problem Statement: How can I change the extension for the spreadsheets that are output by PIMS? For example, I want to change the output spreadsheet extension from ".wk1" to ".xls". | Solution: This setting is accessed by right-clicking on the PIMS model icon and selecting "Output Spreadsheet Extension."
Please see the figure below.
Keywords:
References: None |
Problem Statement: How to review blending information from a central location, instead of using the input tables BLENDS, BLNMIX, BLNSPEC and BLNPROP? | Solution: To review blending data from a central location, the Blending Data Assistant or the Blend Options and Specifications section in the data validation report can be used.
Blending Data Assistant
The Blending Data Assistant can be used to review blending information through a more comprehensive interface that a... |
Problem Statement: Why do I receive the error:
"Export error: The maximum number of columns in an excel worksheet with the current format is 256"
Is there a workaround? | Solution: In Aspen Flare System Analyzer (AFSA), when you run into this 256 columns limit issue, most likely you have too many fittings inside a pipe or too many components. Older versions of Excel used to have the limit of 256 columns. Consequently, lots of components, like the Infragistics that AFSA uses to write to ... |
Problem Statement: Aspen Flare System Analyzer stops without converging and returns the message "failed due to a local minimum." | Solution: You can try the following:
1. In Calculation | Options | Solver page try tightening the tolerance for unit operation & loop pressure
2. If necessary try loosening the tolerance for loop mass balance
3. If above two recommendations does not work try change the loop solver method.
4. Supply esti... |
Problem Statement: Is there any pan option for the Process Flowsheet in Aspen Flare System Analyzer? | Solution: Unfortunately the pan option is not available in the program. However, there are a few options that would help to manipulate the flowsheet view. These are listed below:Â
- Process Flowsheet tab | Zoom section
- Zoom bar
Another option is to use the Locate object function (right click on an empty space... |
Problem Statement: In Aspen Flare System Analyzer V8.8, the Beggs & Brill Liquid Holdup has been added in Methods tab. What is the significance of Beggs & Brill Liquid Holdup and when should it be used and which option to select (original or Payne 1979) | Solution: The option Beggs & Brill Liquid Holdup applies only when you are using either one of the following multiphase pressure drop method:
· Beggs & Brill
· Beggs & Brill No Acc
· Beggs & Brill Homogeneous
The significance of Beggs & Brill liquid holdup is give user an option to either use... |
Problem Statement: Why do I get this error "XML document must have a top level element " when importing sources from HYSYS Relief Valve Sources? | Solution: When importing sources information from Aspen HYSYS Relief Valves, this error warning may show up because the set version for this Aspen HYSYS import file is not same as the Aspen Flare System Analyzer version.
For example, Aspen Flare System Analyzer V8.8 is being used for importing sources from Aspen HYSYS ... |
Problem Statement: When "Rated flow for Node Attached to Tailpipes' option should use in pressure drop calculation? | Solution: The "Rated Flow for Node Attached to Tailpipes" means that, the velocities from the rated flow are used in the pressure drop calculations for any node attached to a tailpipe.
Note that this option affects the nodes pressure drop calculation attached to the tail pipe such as connector, orifice plate, tee, etc.... |
Problem Statement: The "Default" value of the PIPESIM registry key is a version of PIPESIM that is installed (e.g. 2010.1 or 2011.1), and that value is a subkey to the PIPESIM registry key. When Aspen HYSYS fails to find the subkey for the version written to "(Default)" it issues an error message and fails. | Solution: The key should be under either HKEY_LOCAL_MACHINE or HKEY_CURRENT_USER (depending on if the program was installed "for all users" or "current user" option on the computer). The location is Software\Schlumberger\PIPESIM. The subkeys to this key should be the versions of PIPESIM installed, and the "Default" va... |
Problem Statement: APC nonlinear controller frequently loses communication with the Web Interface and freezes | Solution: This issue is typically seen in APC nonlinear controllers deployed through the APC Builder interface (RTE Environment). When this issue occurs, the controller application would turn red on the Web interface and would have a triangle with an exclamation mark signifying loss of communication between the APC eng... |
Problem Statement: How to get rid of below error message while performing Knock-Out drum calculations?
"Not enough data is there to calculate design. Please solve the Rating at least once with the option of saving phase properties" | Solution: Sizing calculations of knockout drum are function of the flow rate upstream of the drum, conditions in the drum (P, T and vapor fraction) and physical properties of the fluid. So before calculating the diameter, you must make sure that phase properties are calculated. Otherwise the above error message will ap... |
Problem Statement: What could cause the error, 'Unable to Load Simulation Case' when an Aspen Plus or Aspen HYSYS file is being imported in Aspen Flare System Analyzer? | Solution: In some cases, when importing Aspen Plus file using the Import Sources/Aspen Plus/HYSYS Relief Valve Sources (as shown below) in Aspen Flare System Analyzer (AFSA or Flarenet) an error will be detected 'Unable to Load Simulation Case'.
One of the reasons could be that the Aspen Plus/HYSYS cases contains the c... |
Problem Statement: After exporting Tray Sizing results to "*.sulcol" file in Aspen HYSYS, why I cannot open this file using SulCol v3.2? | Solution: This is due to a version issue between the exported file from Aspen HYSYS and the current SulCol software. The "*.sulcol" file generated from Aspen HYSYS is currently a lower version (version 2). Between Sulcol v2 and v3, major changes have been done in Sulzer, therefore the file cannot be opened directly fro... |
Problem Statement: How to find the wall temperature of a pipe segment. | Solution: Unfortunately there is no way to see these variables in the Aspen HYSYS pipe segment. The only way to get these temperature values is to do a manual calculation using the reported heat transfer coefficients. The other option is to use the Aspen Hydraulics pipe segment. With heat transfer in Hydraulics, the in... |
Problem Statement: In Aspen Flare System Analyzer, when configuring a Relief Valve, I have to enter a value for the Mass flow and a different value for the Rated flow. What is each one of these being use for? | Solution: By default, Aspen Flare System Analyzer will use the Mass Flow value to calculate pressure drop along all the models in the simulation.
However, the user has the option to configure the flow type that will be used for pressure calculations in some of the simulation objects.
Going to Home | Options | General i... |
Problem Statement: In Aspen HYSYS, you can add compressor curves and create adiabatic plots for values of efficiency and head. The efficiency and head for a specified speed then can be plotted against the capacity of the Centrifugal Compressor.
But if your data is different from the requested by Aspen HYSYS, you must t... | Solution: In this example, we will convert the discharge pressure and power data, to an adiabatic efficiency and head values, by following the next steps:
1. Transform the discharge pressure units to psia/kPa
2. Calculate the adiabatic head using the following equation:
In US units
Had = Adiabatic head, ft*lbf/... |
Problem Statement: How is the Olefin % and Bromine number calculated in Hydrocracker? | Solution: The Hydrocracker will always look at the Bromine number specified for the feed on the Reactor Section | Feed page.
Bromine number is function of the neutral nitrogen, sulfidic sulfur, polynuclear aromatics (3 and 4 ring aromatics) and olefins. When the user enters a bromine number for a feed, the contribution... |
Problem Statement: In the model we apply some bias to some properties (eg. RON). These properties are correctly calculated in the final blend, but when looking at the UBML derived properties (eg. RONE, RON with ethanol) the bias doesn't affect the calculation of the derived property in the final blend. | Solution: As UBML derived properties are very complex, it is highly probable that the property calculation of the blend comes from the components (eg. RON from component 1, RON from component 2,...). The value of bias is applied to the heel, so it will only affect the final blend. As the properties of the final blend a... |
Problem Statement: How do you define the effect of temperature contribution and user supplied DT Contribution overwriting Global dTmin values? | Solution: The Global contribution is defined as (+/-)dTMin/2 for Cold (+)/Hot(-) streams. If you delete ‘Global’ from the Process or Util data DT Cont column then the number entered for that stream (process or utility) replaces the value Global dTMin value ‘Global’.
As an example for a cold stream if Global dTM... |
Problem Statement: How to deploy APC controllers in systems with Trend Micro Virus Scanner? | Solution: The Trend Micro Virus scanner installs the listening service (TMLISTEN.EXE) on port 12345 using HTTP protocol. This conflicts with the RTE service which needs 12345 for the online server.
Symptoms:
· The RTE service appears to start without error but there is no communication from the PCWS to the on... |
Problem Statement: Controller redeploy through APC Builder fails with the following error message in the Event Viewer logs-
AspenTech.ACP.RTE.Remoting.AppAdditionException: Failed to add application to node Online@localhost. ---> System.ApplicationException: Exception caught while adding application data to Node. ---> ... | Solution: One of the most common cause of this issue if that the context/memory regions of the currently deployed application (with the same name) has been corrupted. In such a case, even deleting the application does not clear the online context. The can be confirmed by checking if there are any files referencing the ... |
Problem Statement: Is it possible to import a PIPESIM simulation into HYSYS? | Solution: The Design | Model page in the PIPESIM Enhanced Link block allows the user to import, export, and edit a PIPESIM model.
Clicking the Import button opens the standard Windows file picker property view that allows model selection. Only single branch models identified by the *.bps extension can be selected.
The ... |
Problem Statement: How to edit the performance results table for stream analysis tools. | Solution: The performance results tables for stream analysis tools like Boiling Point Curves, Cold Properties, Envelope Analysis,Petroleum Assay and Property Table can be tailored to the required columns by the user.
Follow the steps below to edit the table columns.
1. Add a Stream Analysis. (In the screen shot bel... |
Problem Statement: When using the PIPE model and another program, very different K factor losses are calculated. For what K factors are Aspen Plus calculating in each section of a pipe? | Solution: Aspen Plus doesn't calculate a loss K factor for the pipe length. Aspen Plus integrates down the length of the pipe to calculate the pressure drop.
For most of the fittings, (gate valves, butterfly valves, Large 90 degree elbows, Straight tees, Branched tees) we do not calculate a K-Value in Aspen Plus. The... |
Problem Statement: In Aspen Air Cooled Exchanger, what is the input “velocity heads for perforated plate pressure drop�, found under Program Options | Methods/Correlations | Tube side tab | Solution: This input item is used for entering the average number of velocity heads lost through each perforated plate in the headers. This Number of velocity heads is used for calculating the pressure drop across the perforated pass partition plates.
Perforated pass plates are usually fitted to strengthen the header i... |
Problem Statement: How to save the simulation and close it, and still be able to review the results later? | Solution: You can get the previous history on opening a simulation doing the following steps:
1. In the Snapshot manager, check the option "Load latest snapshot on opening this simulation"
2. In the Snapshot Manager, on the "Create" tab, select "File saved" to ensure that a new snapshot is created immediatel... |
Problem Statement: When trying to export a model from Aspen Custom Modeler using Visual Studio 2010, the following error message is reported and the export fails.
LNK1123: failure during conversion to COFF: file invalid or corrupt | Solution: This may be due to a problem in Microsoft Visual Studio. See http://msdn.microsoft.com/en-us/library/7dz62kfh.aspx.
To export a model from Aspen Custom Modeler V8.4, you should use Visual Studio 2010 professional edition. There is however a problem if more recent versions of Visual Studio are installed, e.g... |
Problem Statement: How do I un-hide the stream names or the block names for the whole flowsheet?
If you are hiding the labels of all objects, you will not be able to un-hide them using the individual stream setting without un-hiding labels on all objects first. | Solution: There are two visibility settings for labels:
1. Individual settings for each stream and block.
2. Setting for all objects on the flowsheet.
To un-hide labels on all objects, right click the mouse on some empty part of the flowsheet and you will see the command "Hide Labels".
Uncheck that option first, and ... |
Problem Statement: After removing lots of object data from workspace, we are getting the warning ?Unable to resolve trigger dependency?
constantly being logged on journal.log file upon workspace loading.
<<<< ---- End ---- >>>>
<<<< Warning Message[12/02/2013 10:01:31] User='EDP200310G\Administrator' Computer='EDP200... | Solution: Add the below line to the Library Configuration file (cfg).
Journal::defaultReportLevel=Errors
Then proceed to Reset All demons from Rules Editor/ Tools.
?Reset All Demons? rebuilds the triggers by running all defined demon patterns.
There is no danger on running this.
Keywords: Workspace integrity, R... |
Problem Statement: What is the difference between Primary, Secondary, Instrument, Unit Op and Utility connections in the Drawing Editor? | Solution: Connections are links between database objects that represent flows between the objects. The default connections are:
· Primary connection: Line representing the main streams used by the process. It could be identify as the process line.
· Secondary connection: Line not always used by the nor... |
Problem Statement: Tracking memory leak issues effectively. How to export information from Task manager into Excel to track the usage of memory by a particular service. | Solution: When tracking suspected memory leak problems it is common to create excel sheet records with the memory consumed by the services used on the system. Manually entering the memory consumed could be a taxing process since it involves matching the correct PID number for the task and then performing data entry to ... |
Problem Statement: I draw a PFD with some equipment. Now I want to draw some of the PFD equipment into PPID.
For instance, I draw a pump, X-101 in the PFD. When I try to drag this item from the Stock file in order to use it in the PPID, I receive the message "Diagram Type and Symbol doesn't match" and cannot add it. Ho... | Solution: First, it’s necessary to configure the symbol map before being able to drag the symbol on the PPID. Here is the procedure:
1. Right-click on the symbol in the stockpile and select Symbol Map...
2. In the Select Symbol for Diagram Conversion from PFD window, display the PPID library folder in o... |
Problem Statement: Is there a quick and efficient way to stop all Aspen services on APC servers? | Solution: When applying an APC software cumulative patch or emergency patch to an APC online system there is a requirement to stop all online applications and stop all Aspen services from the Services window. Manually stopping the services could be time consuming since this involves selecting each service from the Serv... |
Problem Statement: When you install Aspen Basic Engineering Server, then the installer ask for SQL Server 2012 Express
How to work around this? | Solution: Below is the workaround:
1. There will be a setup.xml file on the installation folders. Please open the setup.xml file.
2. Search for the following text:
Name="Aspen Basic Engineering Server"
3. There will be two instances of this seen.
4. Carefully remove just the following line fro... |
Problem Statement: Is it possible to recover a single diagram from the Drawing Editor if it was deleted from workspace? | Solution: There is no way to recover a single diagram from the Drawing Editor if it was deleted from workspace.
If it was backed up, you may be able to recover it by importing it to the workspace, or if it was exported before using the package.
Keywords: Restore, Drawing Editor, back up
References: None |
Problem Statement: How do I change the label units inside the Drawing Editor? | Solution: Inside the Drawing Editor Menu, go to Labels and select Change Unit Set…:
The select Unit Set window will be displayed and then you can select the units you want to have on your labels (Metric, SI, Imperial, and so on):
Keywords: Change Unit Set, V8.4, Drawing Editor
References: None |
Problem Statement: Radio Buttons in Excel Datasheet editor doesn't work with "Cross" and "Check" options. Why? | Solution: The Excel datasheet editor does not support radio buttons with "Cross" and "Check", only with "Fill". It is not feasible due to constraints within Excel. This is already noted down as an enhancement in our system and will be addressed in the future.Â
Keywords: Radio, fill, cross, check, excel, datasheet
Refer... |
Problem Statement: Clicking Radio buttons gave users an error "Cannot run the macro A3183177.VBAMacro_Field895. The macro may not be available in this workbook or all macros may be disabled." in Excel Datasheet Editor. How can users solve this problem? | Solution: The problem might be because users did not save the datasheet definition file extension as *.xls in V 8.8. If you did not save the file extension to the required standard, it will cause problem when generating the ztx template. Hence, the radio button will be disabled when opening the datasheet in the Excel D... |
Problem Statement: Is it possible to configure DMCplus such that the controller will run for some time based on its internal prediction for non-intermittent CVs? | Solution: The above outcome can be achieved by using internal calculations in DMcplus. Mark the CV in question as an intermittent CV (even though the analyzer provides a new values every minute) and then add an input calculation to the controller that will update NEWPV based on change in the measurement that have been ... |
Problem Statement: Why are symbols grayed out in the Drawing Editor on a client machine? How do I fix it? | Solution: In a Server-Client set up, the symbol library should be specified as UNC ( Universal Naming Convention) path so that it can be accessed from multiple client machines. The format of UNC path is:
\\machine name\Share name\Directory path, machine name is server name, share name is name of share on the machine... |
Problem Statement: How does Aspen DMCplus handles transform variables in Control, Smart Step and Calibrate? | Solution: For the MVs the following variable attributes are transformed before the engine calculations are performed:
1. VIND Input value
2. ULINDM/LLINDM Upper/lower operating limits
3. UMVENG/LMVENG Upper/lower engineering limi... |
Problem Statement: Controller participating in a composite has FFW switch as "Operator switch off" despite it being set to ON. | Solution: Applications in the composite work in a particular manner, especially when the controllers in the composite have feed forward (FFW) variables with the same name. In situation like this, the switches in the FFW variable for the first controller in the composite list is used as the switch for the same variable ... |
Problem Statement: When running 4x4 gain matrix analysis or a 3X3 gain matrix analysis on a large model it is possible that DMCplus Model may require a long amount of time to compute the result. This sometimes leads to a non-responsive DMCplus application. This behavior is specific to system which is loaded and running... | Solution: The recommended solution is to use a system which is an isolated offline machine is not running another programs while DMCplus model is performing this heavy computation of 4 X 4 gain matrix for a large model.
For a very large model of the order 50MVs x 60 CVs the 4x4 gain matrix analysis could take a computa... |
Problem Statement: How do I replace the AspenTech logo with my company's logo in a border label? | Solution: · Open the label border symbol with the Graphic Definer tool.
· Delete the AspenTech logo (select the logo and click delete button on the keyboard).
· Go to the Insert tab ribbon | Objects…
· In the Insert Object pop-up window unselect Link checkbox and look for the bitmap... |
Problem Statement: Collect.exe, a data collection program on the online server, crashes even though all the tags are valid and it passed validation (i.e, dmcpcollect -v taglist) | Solution: The name of the tag list has to be 15 characters or less. Renaming the file name of the taglist to be less or equal 15 characters would fix this problem
Keywords: collect
dmcpcollect
References: None |
Problem Statement: SQLplus EXECUTE statement can execute query code on remote database like Oracle or MS SQL, syntax needed by queries to run on other database need to use single quote marks which will be interpreted by SQLplus as a close character for the current EXECUTE line statement if the query is written on SQLpl... | Solution: Single quote character can be included on EXECTUE statement like is show in this example:
Execute 'UPDATE MyTable SET MyDate = ''24-JUL-15 00:04:57.5'' '
On MyRemoteDB
A single quote mark can be added by using two single quote characters ('' not ") as part the query string. Other special characters
Keywo... |
Problem Statement: Aspen SQL plus query writer shows error "Failed to connect to Server", on launch, in Aspen IP21 client system.
Tag browser shows "Server (nodename): [AspenTech][SQLplus] Failed to connect to server". | Solution: When trying to connect to the Aspen Infoplus21 server through Aspen SQL plus, it shows error "Failed to connect to Server".
At the same time, tag browser also shows error "Server (nodename): [AspenTech][SQLplus] Failed to connect to server".
There could be multiple reasons for this issue which are listed with... |
Problem Statement: Is there a way to read HTRI files directly into Aspen Exchanger Design & Rating (EDR)? | Solution: Yes, by reading the *.DBO file. This output file has to be explicitly cleated by HTRI.
The fluid properties are not in the *.DBO file. So, when you import a *.DBO file in EDR, the geometry is pulled in but not the fluid properties. EDR can create both a thermal and mechanical file.
To open this HTRI ... |
Problem Statement: How do I transfer HTRI files to Aspen Exchanger Design and Rating (EDR)? | Solution: We can only open .dbo or .out format HTRI files in Aspen Exchanger Design and Rating. So, please save your HTRI files in .dob or .out formats to be able to open with Aspen Exchanger Design and Rating.
Click on file << Open HTRI, you will be able to browse .dob or.out files. Now Click on File << Save HTFS.
Thi... |
Problem Statement: How to create a new flowsheet in Aspen PIMS Platinum? | Solution: To create a new flowsheet in Platinum:
1. Click Create New Flowsheet icon in tool bar.
2. Enter flowsheet name and select group, equipment and streams you want to display on the new flowsheet.
3. Click Finish to generate new flowsheet.
4. The new flowsheet will show the selected streams and the selected units... |
Problem Statement: What is the definition of the total, effective and required area and the difference between U clean, U dirty and U service? | Solution: - The total area of the heat exchanger is determined by the PI (3.14) * Tube Outer Diameter * Tube length * Number of tubes * number of shells.
- The effective heat transfer area is the area available for heat transfer (this is also often referred to as the actual area). This is the total area minus areas whi... |
Problem Statement: How can you get vapor/liquid densities for each stage with a time profile? | Solution: User can use new form to customize a time profile with vapor density and liquid density for each stage.
1. Click Tools from the menu and select new form. Choose History table and you will see a blank form is open.
2. Go to profile results and properties tab. You will be able to see a profile table for liquid/... |
Problem Statement: Are Aspen EDR tools integrated with any 3D modeling software? | Solution: EDR interfaces with Autodesk Inventor for 3D modelling. You can either run it directly from shell and tube (thermal) or transfer the data to mechanical design (S&T mechanical) and finally export to Inventor.
Make sure Inventor is installed. To do this, one has to go to File | Export and then choose Inventor... |
Problem Statement: Type ahead search in aspenONE Process Explorer (a1PE) V8.8 is not working. | Solution: 1. Make sure IP.21 is running in the license granted mode
2. Go to http://localhost/ProcessExplorer/webcontrols/pbitemdetails.asp?admin=true , press start scan, make sure # of tags are not zero
Go to start->all programs->AspenTech->Common Utilities-> right click on “ADSA Client Config Tool x... |
Problem Statement: What does ET tracking means and how to change the default behavior? | Solution: When ET tracking is enabled on a particular variable, the engine sets the ET value equal to the Steady State Target of the variable on the first cycle when ET service is turned ON for that variable. This is the default behavior. In some situations, it might be desirable to have the ET track the current measur... |
Problem Statement: How to fix operation warning 1325?
Also applicable to operation warning 1326 and 1327.
Operation Warning 1325: The required fraction of the surface area for cooling the liquid phase is approximately y %. However the number of naturally submerged tubes, calculated using a pressure drop model is --, ... | Solution: In EDR, the tube submergence is roughly estimated at each numerical iteration based on the shell inlet and outlet conditions, without involving the details of the interval points (because those come after this initial estimation).The value recommended by EDR in the warning message should be taken as a rough e... |
Problem Statement: How to set up clustering for web based applications like aspenONE Process Explorer (A1PE), ADSA and AFW? | Solution: Aspen MES web applications like A1PE do not have any built in functionality that will help them failover to secondary server. In order to implement clustering on Aspen MES web applications IIS needs to be set up as per the following Microsoft solution to failover to secondary node.
https://support.microsoft.c... |
Problem Statement: Can Pot Pressure be used as trigger value in Operating Steps? | Solution: From V8.8 onward, Batch Modeler has the option of specifying Pot pressure as a Trigger Value.
To access the Trigger value, please go to Navigation Panel > Operating Steps > Step > End Condition.
Please see this screen shot as an example:
Key Words
Operating Steps, Pot, Pressure, Trigger
Keywords: None
Refer... |
Problem Statement: Some tags have multiple map records assigned. How do I change the map record being used by an aspenONE Process Explorer plot? | Solution: To change the map record being used in a plot you need to edit the properties of the tag being plotted. Click on the Edit Pen icon next to the tag you want to change. The expand Source, and select the map record to use from the Attribute drop down box.
Keywords: Map record
A1PE
Aspen One Process Explorer
Re... |
Problem Statement: Is there a way to include gravity effect on pressure drop calculations? | Solution: Yes, there is a way to include the gravity effect along with friction. You make this selection by going to Input | Program Options | Thermal Analysis | Pressure Drop Tab.
However, when using this option approximations are used in calculating gravitational changes. For instance height changes in nozzles and ... |
Problem Statement: How do I prevent the warning that appears when heat load is close to the maximum possible value? | Solution: Go to Input / Application Option/ Calculation Method. Change Calculation option method to Advanced Method.
Go to Program Options / Calculation options and reduce the convergence tolerance - heat load value.
Keywords: Heat Load, maximum possible heat load, Tolerance
References: None |
Problem Statement: How to select tubes for vibration analysis check in rating mode. | Solution: The program-selected vibration tubes are chosen to be representative of potential worst cases. You will see that they are concentrated in the baffle windows, where support for the tubes is less frequent, and near inlet and outlet nozzles, where flows are highest.
User can also nominate addition tubes that are... |
Problem Statement: What are different options for acceleration to be included for Pressure drop calculations in Heat Exchangers? | Solution: There two options for including acceleration and these can be selected from Input | Program Options | Thermal Analysis | Pressure Drop Tab.
The default settings 'Acceleration during heat transfer' considers the acceleration pressure recovery during condensation and for all other changes associated with densit... |
Problem Statement: When you go to the Dynamics tab on the Hydraulics subflowsheet, the program mentions that there is a limitation with the dynamics solver saying that it provides a non-compositional model
If Aspen Hydraulics does not take into account compositions, how does it work with composition on Dynamisc mode? | Solution: Aspen HYSYS unit operations typically solve to equilibrium conditions using an equation-of-state or activity model. On the other hand, Aspen Hysys Hydraulics uses a non-compositional model, commonly used in the upstream industry for modeling petroleum fluids.
At the wellhead, the full compositional breakdo... |
Problem Statement: What is Exchanger Effectiveness and how can this be used in Aspen Shell & Tube Exchanger? | Solution: The effectiveness of a (two-stream) exchanger is the exchanger heat load as a fraction of the maximum possible heat load. The maximum possible heat load for a given set of process inlet conditions occurs either when the hot stream is cooled to the cold stream inlet temperature, or when the cold stream is heat... |
Problem Statement: How do I transfer a database from one version to another? | Solution: To copy a database (for example costing database) instead of copying all the *.PDA and *.MDB files from the old customized default folder to the new default folder, Version Control Utility could be used.
From the Windows Menu go to “All Programs� > AspenTech Folder > Exchanger Design and Rating V8.x > S... |
Problem Statement: The Custom Stream Summary is blank.
Also, streams seem to be reinitialized at the end of a run.
i.e.
For example, in the Control Panel at the end of a run it shows:
->Generating block results ...
Block: B1 Model: HEATER
->Simulation calculations completed ...
REINIT REPORTFL COMMAND OPTIONS MENU, TY... | Solution: Check if you have file called atxc.dll in the C:\Windows\system32 directory. If yes, rename it (later you can delete it, if it doesn't break anything). This .dll affects communication in Aspen Plus and Aspen Properties. The old version of the .dll in the system32 directory comes from a 12.1 installation and c... |
Problem Statement: When a CalcScript formula that includes a MovingAverage function call is executed an "error executing method" message is generated or even the AspenCalc Windows service crashes completely and requires restarting manually. | Solution: The MovingAverage function is designed for ad-hoc calculations and not scheduled calculations. The MovingAverage function calculates the time-weighted average value of a tag.
Within a CalcScript formula use the TagAverage built-in history function instead. This function calculates the average of a tag over a ... |
Problem Statement: When using CalcScript to create calculation, there is a need to CAST or CONVERT a text string to generate a fixed timestamp.
However, there is no such in-built functions available in CalcScript. | Solution: There are in-built functions which are capable of obtaining the various time component such as:
· DAY
· HOUR
· MINUTE
· SECOND
It is possible to calculate and set a fixed timestamp using the above in-built functions.
The below CalcScript uses the timestamp function NOW to retur... |
Problem Statement: How does one enable error logging for Process Recipe? | Solution: Process Recipe has the ability to log verbose usage/error messages to a text file. Error logging can be enabled on either the Process Recipe client PC or on the Process Recipe server.
To enable verbose logging one needs to modify a registry key. Do this as follows:
Open the registry editor, regedit.
Go to HKE... |
Problem Statement: How to change the elements in a default layer type? | Solution: You will initially see a set of defaults. The basic default sequence for each stream in the layer type (after an initial end bar) is shown below:
It is possible to modify any item. The corresponding defaults in the other columns in the table will also adjust accordingly.You can change layer elements to repres... |
Problem Statement: How do I install the Enterprise Update Center pre-requisites on Windows Server 2012? | Solution: Step 1: Load up Microsoft Server Manager
Step 2: Click on “Add roles and features�
Step 3: Enable “Web Server (IIS)� then click Next
Step 4: Make sure you have the following pre-requisites enabled
Security:
· Basic Authentication
· Windows Authentication
Application Development
In th... |
Problem Statement: Does the aspenONE V8.8 suites support Windows 10? | Solution: The V8.8 release supports Windows 10, with the following exceptions:
Engineering products that do not support Windows 10:
· Aspen Process Tools
Manufacturing & Supply Chain products that do not support Windows 10:
· Aspen PIMS Platinum
For the full aspenONE V8.8 Platform specifications, c... |
Problem Statement: Do I need a new license for aspenONE Suite V8.8? | Solution: If you are planning to upgrade to aspenONE V8.8 and wondering if you will need a new license then this knowledge base article will help you answer your question.
In release of aspenONE V8.8 Suite there are no new license keys so you will not be required to obtain a new license file.
However if you are using a... |
Problem Statement: What are the system/hardware requirements for aspenONE Engineering V8.8? | Solution: Supported Operating Systems
· Windows 8.1 Update Professional and Enterprise (64-bit)
· Windows 7 SP1 Professional and Enterprise (32- and 64-bit)
· AspenTech recommends using a 64-bit Operating System for Activated Engineering, RefSYS Refinery Reactors, when working with large models... |
Problem Statement: What does "CCF_KW_WRITE" errors mean? What are the typical causes of the "CCF_KW_WRITE" errors in a online inferential application? | Solution: The "CCF_KW_WRITE" errors typically occur for a controller when the controller is having problems writing out values to specific tag on the DCS. The “CCF_KW_WRITE” could be caused because of multiple reasons, which are listed below-
1. Incorrect tag name defined in the IQF file. This typically happens if ... |
Problem Statement: Where are the SLM client tools located in V8.8? The SLM client tools (SLM Configuration Wizard, SLM License Profiler, SLM Commute...) are under folder common utilities in previous versions (V8.7 and below). E.g. Start | All Programs | AspenTech | Common utilities. However, in V8.8 the SLM client tool... | Solution: In V8.8, the SLM client tools are under folder Aspen SLM (aspenONE SLM License Manager): Start | All Programs | AspenTech | Aspen SLM | aspenONE SLM License Manager.
Keywords: SLM Client tools, SLM configuration wizard, SLM license profiler
References: None |
Problem Statement: Common Questions and Answers for aspenONE V8.8 Suite. | Solution: Engineering Deployment V8.8
1. What are the system/hardware requirements for aspenONE Engineering Suite V8.8? View KB
2. What are the prerequisites for aspenONE Engineering V8.8? View KB
3. Do I need a new license for aspenONE Engineering Suite V8.8? View KB
If you would like more documentation ... |
Problem Statement: How does Aspen IQ apply and use transforms to the various variables involved with the prediction equation? | Solution: The built-in transform option in Aspen IQ is only available to use with the inferential output. All bias update calculations are performed in the transformed domain based on the transform function applied to the output variable. The input variables to the inferential can be transformed using input calculation... |
Problem Statement: When starting an installation of the aspenONE V8.8 Engineering Suite, during the prerequisite checking stage, the installation will look at the computer to determine if there is enough system memory or RAM available. If not, then this message will display:
"aspenONE requires a minumum of 8GB RAM. Pl... | Solution: The installation retrieves the installed memory size from the Windows Installer property "PhysicalMemory", which is defined as "The installer sets the PhysicalMemory property to the size of the installed RAM in megabytes". And it compares the property's value with 8192 to determine if machine has sufficient p... |
Problem Statement: Aspen Framework (AFW) Tools have a "Transfer AFWDB Data" utility which allows users to export AFWDB PROFILES, ROLES and APPLICATIONS to XML files. These XML files can later be imported into AFWDB databases by using the Import function.
Some of the questions that might arise during this process are:
?... | Solution: The default Export path for the Transfer AFWDB Data utility is C:\Documents and Settings\<current user>. The default file names are BPEPROFILES.XML, PFWROLE.XML and PFWAPPL.XML for Profiles, Roles and Applications respectively. The path and file names can be manually specified by the user. For example:
NOTE: ... |
Problem Statement: This document presents a procedure for migrating an Aspen Local Security installation to Aspen Framework without respecifying any of the role-based security data. | Solution: Backup and save the AFWDB.mdb Access Database file in a work directory that is not part of the AspenTech installation path to protect it from deletion in the next step.
Deinstall Local Security.
Install the Database Manager (MS SQL or Oracle), the Aspen Framework Server and Client Components. The AFWDB data... |
Problem Statement: Which model settings are used in MPIMS and XPIMS models for AO? | Solution: When using an M/XPIMS global model with Advanced Optimization (AO), you have the capability of setting many model settings at both the global and local model levels. This document describes which of these settings are active for a global model or local model.
The model setting is available at the model tree, ... |
Problem Statement: When installing the 64-bit version of AspenTech Manufacturing products including Aspen Cim-IO, is any of the Aspen Cim-IO product 64-bit, or is all of Aspen Cim-IO 32-bit? | Solution: The only parts of Aspen Cim-IO which are 64-bit are the client tasks, like the main, asynchronous, and unsolicited tasks (TSK_M_XXXX - cimio_c_client.exe, TSK_A_XXXX - cimio_c_async.exe, TSK_U_XXXX - cimio_c_unsol.exe). Everything else is 32-bit. So on an Aspen Cim-IO server, it will all be 32-bit. On the ... |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.