question
stringlengths
19
6.88k
answer
stringlengths
38
33.3k
Problem Statement: On the Data tab, the External Changes icons are always grayed out, when do they become active?
Solution: The two icons in the External Changes section of the Data tab become active after you have imported data into SCM, at that time you must decided to accept or reject the changes that were brought into SCM from an external source. Keywords: Plant Scheduler Supply Chain Planner References: None
Problem Statement: To control the cut point in the Crude Units, user created structure had to be incorporated in table ROWS. This kind of structure can be made more user friendly and easier to set up by using table PROCLIM. This document explains how to set up the required structure.
Solution: The overall structure required is to capture the activities of the swing cut columns in table ROWS, drive them to submodel created ad hoc and setting up the cut point limits in the submodel through the use of table PROCLIM. We will base this example (see attached model) on Swing Cut KD1 for Crude Unit 1 (SCD1...
Problem Statement: A user that was trying to remove a property from an existing blend event in Aspen Refinery Multi-Blend Optimizer (MBO) decided to remove the property totally from the product, using the PRODUCT dialog menu. However, while MBO easily let him remove the property from the product, and even though he man...
Solution: This issue only occurs in versions earlier than V7.3.1. Some properties cannot be deleted because other properties may depend on them. If the required properties are not present, the simulator adds them. In V7.3.1, the design of the Product dialog has been improved. In V7.3.1, the Product dialog box allows ...
Problem Statement: After a BCI model is loaded, the status window shows a message 'Recipe list not loaded'. What does that mean?
Solution: Check under Menu Tools | Program Options ?, and see if the box at the bottom 'Only FTP PREP Input File to BPC' is checked. FTP is activated only if login and directory information is provided in this section. Otherwise, if this section is left blank, BCI assumes a local directory structure exists and that r...
Problem Statement: A new property, "MultipleEvents", has been added in Aspen Refinery Multi-Blend Optimizer (MBO) and Aspen Petroleum Scheduler (APS) to the .EventsColl object that allows you to specify if you want the system to refresh all screens each time multiple events are added.
Solution: In Aspen Refinery Multi-Blend Optimizer: The OrionMBO.EventsColl object exposes the following property: Property Option Description MultipleEvents OrionMBO.enEVENTS.EVENTS_MULTIPLE Use automation to add multiple events without refreshing/simulating each time an addition/modification has been made. Refresh w...
Problem Statement: In V7.3.1 when using PIMS-AO, the XLP matrix generator will flag errors if there are cells with errors, such as #NAME, #REF, etc. in Excel input tables. How can I find all of these to correct them?
Solution: Below is an example of macro coding that can be used to find each instance in a workbook of an error. The macros creates a sheet named "Errors" which contains the locations of all the #REF, #NA, #DIV0, etc. Excel errors in the workbook. You can click on the error and it will take you to that cell if you have ...
Problem Statement: Aspen Base Load Service has been installed and worked correctly. After a few days the service has suddenly stopped. When trying to start the service manually from Administrative Tools > Services, the following message is returned: "The Aspen Base Load service on Local Computer started and then stopp...
Solution: Possible cause of this problem is overflow of Windows Event log. Check the Windows event log as follows: 1. Open Control Panel > Administrative Tools 2. Click on "Event Viewer" 3. Open "Application" Event If there are a lot of events for "Aspen Base Load", clear the log using the following steps: 1. Right...
Problem Statement: In solution 122451, it describes how to control swing cuts using Table PROCLIM by adding a dummy submodel. This solution is an alternative that also uses Table PROCLIM but omits the dummy submodel.
Solution: To implement this technique, user needs to be familiar with the PIMS matrix row names that PIMS generates from PROCLIM. For example, let's use the Volume Sample model as attached, the purpose is to control the percentage of SCR1 swing cut KD1 that swings up. This will be represented by the PROCLIM entry of Z1...
Problem Statement: Aspen PIMS V7.3.1 has a new function called Assay Manager which can be launched from model tree by right clicking on the ASSAYS branch. Some users have noticed that Assay Manager does not launch and a message "No data returned from Assay Manager" is displayed in the execution log.
Solution: Assay Manager will be installed in the following directory, C:\Program Files\AspenTech\Aspen Feedstock Assay Manager If it is not there, Assay Manager is not installed. Aspen PIMS V7.3.1 now has a prerequisite that Microsoft .NET Framework 4.0 be installed. The installation of Microsoft .NET Framework 4.0 is...
Problem Statement: Is it possible to export the planning board graphic from Aspen Plant Scheduler to Excel via the "Export to Excel" selection on the File menu?
Solution: Exporting the planning board graphic is not supported at this time. Exporting from the "Export to Excel" selection on the File menu only supports the exporting of sets and tables, not graphics. Keywords: None References: None
Problem Statement: How do I improve the Oracle publishing performance of Aspen Petroleum Scheduler?
Solution: Beginning with Version 8.4 , users can improve Oracle performance on Publish by adding the keyword ORACLE_DELETE_RESULT_TBL_W_TMPTBL with the value "Y". This prompts APS to use the temp table to copy the data to be retained, truncate the existing table and then copy back the data to the results table again....
Problem Statement: When updating an Aspen Petroleum Scheduler (APS) database to version 7.3, I got some validation issues related to "Order Problem" in some tables, such as: Table _LINEFILL Order Problem: [ID] is 9th column, should be 1st column. Order Problem: [CASE] is 8th column, should be 5th column. How do I k...
Solution: When DBUpdate utility (or script created by the utility) is running to upgrade a model, it cannot modify the order of fields/columns, change field/column names or delete fields/columns in the database. After updating a database, we strongly recommend that you run a DB validation to verify that there are no re...
Problem Statement: How do the "Copy" and "Copy and Link" functionalities work in Aspen Petroleum Scheduler (APS) V7.3? Can you suggest a practice to use the new functions in order to have same results in terms of number of steps to do comparing with v2006.5 ?
Solution: Here is the explanation of how to use some shortcut menu options related to Events. All of them will be available when a desired event is selected and you right click on the Gantt chart. APS v2006.5: "Copy" functionality: This task is used in the Event interface to copy and link an event on an event screen ...
Problem Statement: New Dialog boxes have been added in Aspen Petroleum Scheduler(APS) v7.3.1 to avoid data tables manipulation.
Solution: Previously, direct manipulation of data tables was required to enter and modify component, product and tank information. In V7.3.1, dialog boxes have been added that allow you to make changes through the APS interface. New Tables: - COMPONENT Dialog box - PRODUCT Dialog Box - TANK Dialog Box COMPONENT Dialo...
Problem Statement: This article describes the procedure to create templates in Aspen Petroleum Scheduler (APS) that can be used in Excel to edit multiple events at the same time.
Solution: Editing multiple events in Excel is performed by defining templates that are applied to Excel spreadsheets The template you create defines what and how specific types of data are displayed in Excel. Your customized display allows you to quickly view, edit, add or delete information that most easily fits your ...
Problem Statement: A new field, "Plot Title", has been added to the Layout Options dialog box that allows you to add a title to trend charts.
Solution: Enter a title for the plot from the "Layout Options" dialog box. Right click on the desire trend, as shown: This title appears at the top of the trend chart: If this field is left blank, the text associated with the first trend?s Description field appears at the top of the trend chart, as shown: Keywords: T...
Problem Statement: When selecting some events in Aspen Petroleum Scheduler (APS), then selecting the option--"Edit in excel", it pops up the following error messages, as shown below : How I can fix these warnings to use "Edit Events in Excel" functionality?
Solution: Microsoft Office adds a security option to deliberately lock out programmatic access to the VBA object model from any Automation client unless a user chooses to permit such access. This is a per user and per application setting, and denies access by default. This security option makes it more difficult for u...
Problem Statement: This is the procedure to select a Multi-Event editor Template and then to launch to Excel to edit, add and delete Event data in Aspen Petroleum Scheduler (APS) and Aspen Refinery Multi-Blend Optimizer (MBO).
Solution: Steps to edit, add or delete Event data using the Multi-event editor template: 1. On the Event interface, select the events you wish to edit. You can either use SHIFT+click to select individual events or click and drag around the desired events to select multiple events.Your selected events are highlighted. ...
Problem Statement: When creating a method CreateEvent() for Material Service - I get the message: "You can not create an event Material Service... Just edit...". Are there any ways to create event Material Service automatically in VB.Net?
Solution: The CreateEvent() is the 2006.5 type of automation call to create an Event. This method does not support Material Service Events but there is the newer method of creating events using the EventColl Interface. The CreateEventItem() and Add() can be used to create a new event of type "Material Service" or any ...
Problem Statement: We are getting an error as shown below when Aspen Petroleum Scheduler (APS) is opened. We think its due to the fact that some refinery data imported into APS is negative but we cannot determine what the value is from the xseq number. Could you please let us know how to determine what the X_SEQ 233220...
Solution: The Error log is showing there is a negative quantity value (this is probably because the Start time is later than the Stop time of an event) . What you can to do: From the database or APS, select ATOrionEvents table, scroll right until find X_SEQ column, select it and right click to select FIND option. Wri...
Problem Statement: How do I find out the calculation sequence of the units in Aspen Petroleum Scheduler (APS ) V7.3? In version 2006.5 I could go to the log table and look at the UNITS tab and it would show me a seq number for each unit indicating the calculation order.
Solution: If the DBGINFOLEVEL in CONFIG is set to "100" then the unit sequence is written to OrionDbg.txt . We attached a sample file to this solution. The OrionDBG.text file located on the "Local Working Directory" folder defined under "User Settings" It will shows information like this: (see attachment for more d...
Problem Statement: This knowledge base article describes how the "Transportation mode" field can be added using the Automation call "Create Events" for "Product Receipt Event" in Aspen Petroleum Scheduler.
Solution: Here is a code example to create a new "Product Receipt" event. Note there are some rows related to Event parameters called: ID, ID1, ID2, and ID3. Depending on the information that user requires, for example, "Transportation mode" for "Product Receipt" event, ID3 must to be fill up. Then , for the above exam...
Problem Statement: How does the parameter RESULTS_CLEAR_DAYS that is in the CONFIG table work? What does a value of zero indicate and what does a positive value mean (say 10)?
Solution: The keyword RESULTS_CLEAR_DAYS will be populated (VALUE field) from selected option in "Model Settings" called "Clear Normalized Publish Tables". This option allows the user to clear published results from the data table _EVENTS. If you click this option and leave the default value "0", Aspen Petroleum Sche...
Problem Statement: How do I edit multiple events in Aspen Petroleum Scheduler (APS) and Aspen Refinery Multi-Blend Optimizer (MBO) using Microsoft Excel?
Solution: As of V7.3.0.3, there is new functionality called "Edit Event in Excel" that allows users to modify multiple events at the same time using Excel. Multiple Events can be edited using the existing "Multiple Event Editor" dialog box implemented in V7.1 or by using "Multi-Event" Editor templates with Microsoft Ex...
Problem Statement: When trying to exit from Aspen Petroleum Scheduler (APS) V7.3.1, the message shown below appears often. It can take minutes until we are able to exit. Why is this message prompted, and how do I prevent it?
Solution: We implemented a Logic in Aspen Petroleum Scheduler (APS)/Aspen Refinery Multi-Blend Optimizer (MBO) that prevents two users from saving at the same time. It goes something like this: -User "A" saves, an entry immediately goes into the SCHEDULE_LOG table with the DESCRIPTION : 'Saving Events' -When user "A" i...
Problem Statement: After changing my window authentication password, I now cannot use the functionalities "Passing Assays from PIMS to APS" and "KPI Targets passing from PIMS to APS".
Solution: During the APS installation procedure, if you are installing APS Integration services, you will always see the User name and Password dialog box. If you enter a user name and password, the OrionSvcHost service will be installed using the entered User account name and password. If you select the Skip user/pass...
Problem Statement: How can I specify a different property method for the distillation part and the condenser of a column in Aspen Batch Modeler (ABM)?
Solution: In order to specify a different property method for the distillation part and the condenser in ABM V8.8. In the standalone ABM interface, one can specify new component list for the condenser, and set the component list to the below two variables: Condenser.Componentlist Drum(1).ComponentList 1) Under Confi...
Problem Statement: This knowledge base article describes why the Blend Control Interface (BCI) does not pick up the NumericLowLimit and NumericHighLimit.
Solution: If the model has blender.cfg file, BCI will read the Low limit and High Limit from the .cfg file. Otherwise, BCI will read from NumericLowLimit and NumericHighLimit of CustomMap table, these two limits are blender specific, not product specific. So if we set NumericLowLimit and NumericHighLimit for each produ...
Problem Statement: How to fix dbupdate error: Failed to execute command, Invalid field data type
Solution: The error show in screenshot may appear during database conversion This error is caused because the application failed to modify Int32 column to AutoNumber when the table has records. To fix this the user can modify it manually by baking up the data, changing the column type to AutoNumber, then importing...
Problem Statement: New automation object was added "OrionMBO.RecipeMIPUDTVar" in v7.1 that allows user to pass information to and from Aspen Refinery Multi-Blend Optimizer(MBO) Automation functions defined in the RecipeMIPUDT interface
Solution: The purpose of OrionMBO.RecipeMIPUDT is to allow user to control the MIP volume and MIP recipe settings for events in Multi-Blend Optimizer. Use the OrionMBO.RecipeMIPUDT object to expose the methods listed in the following topics: Properties Description fMinPercent This property contains the component thre...
Problem Statement: This knowledge base article describes how to reconfigure olefin plant penalty coefficients.
Solution: Follow the steps to check and modify the settings. 1. Go to the directory on the server where Aspen Olefins Scheduler is installed. By default, it should be C:\Program Files\AspenTech\Aspen Olefins. 2. Locate the file ATEthyleneSystemConfiguration.exe and double click to open it. 3. ...
Problem Statement: After installation, I cannot open the Matrix Analysis Program. If I try to open it from within Aspen PIMS, I get the following error: "Unable to launch the Matrix Analysis Program (MAnal.exe) Please make sure that this program has been properly installed and OLE registered." If I click on the...
Solution: First, make sure that the following dlls are present: SharedResDLL.dll xlpxmps.dll DataConnectWrapper.dll Then, re-register the MAnal.exe executable: 1. Open a command prompt with administrator rights (Run as Administrator) 2. Navigate to C:\Program Files\AspenTech\Aspen PIMS (or the location of MAn...
Problem Statement: How does DBUpdate handle case and column orders in Aspen Petroleum Scheduler (APS) and Aspen Refinery Multi-Blend Optimizer (MBO)? Here is a validation report getting after run DBUpdate showing some order problems:
Solution: The DBUpdate utility (or script created by the utility) cannot modify the order of fields/columns, change field/column names or delete fields/columns in the database. After updating a database, we strongly recommend that you run a DB validation to verify that there are no remaining structural errors that the ...
Problem Statement: Can the characteristics of a falling film or thin film evaporator be modeled with the Aspen Engineering Suite (AES)?. Which component of AES is suitable? Are there designated unit operation models to represent a falling film evaporator, and - if not - how can existing unit operation models be applied...
Solution: This solution presents a few ideas and approaches to model falling film evaporators: Aspen Plus Simulate the falling film as a series of Flash2 blocks, each with a specified duty, the sum of the duties being equal to the overall evaporator duty. The vapor from a subsequent flash could be fed back to the previ...
Problem Statement: What are the recommended best practices for backing up and restoring clustered computer nodes for an MES clustered InfoPlus.21 system that is based on Microsoft’s Clustering feature?
Solution: In general, there are two ways to perform a backup of an IP21 system: 1. Full System Backup – such as using third-party backup software to fully backup the nodes of a cluster including the shared disk(s). 2. Data Backup – such as backing up only the IP21 data files, including the latest snapshot and the histo...
Problem Statement: When exporting a model from ACM, you might want to invoke nmake manually over the intermediate files generated by ACM in order to troubleshoot any possible errors. If the following error appears: "nmake -f MakeUntitled command failed (return code 2) Is C++ (required to export compiled flowsheet) ins...
Solution: 1. In ACM go to Tools > Settings > Export Models and uncheck "Delete intermediate files" 2. Export your model and even if the process fails, you will notice that in the working folder some files will be generated, these contain the c++ source code and nmake script among others. 3. Open a cmd window (Start Me...
Problem Statement: What Prop-Set can be used to report the mole fraction of a component on water-free (dry) basis?
Solution: 1.Click on the Prop-Set form and select MOLEFRAC (Mole fraction for a component in a mixture). As shown below: 2. Open the Qualifiers sheet, select Total as Phase and Dry for Water basis 3. Make sure to include the Prop-Set into the report. Go to => Data Browser | Setup | Report Options | Stream. Click ...
Problem Statement: How can we limit the property of a crude cut in Aspen PIMS?
Solution: The method for limiting a crude cut property that is easiest to implement involves a dummy submodel with a process limit row (a Z-row) to implement the constraint on the crude cut property and Table PROCLIM to implement the property limit. We will show an example in which we wish to limit the volume percent a...
Problem Statement: How to use the "red line" in v7.3 to drag around the Gantt and trend charts to delineate a specific time when looking at events.
Solution: From the ?Period bar? located at the top of a Gantt chart (third object), use the slider(diamond symbol) to move the red line: Keywords: References: None
Problem Statement: This article describes the steps to install Excel Integration Utility (EIU) in Excel 2003 specifically.
Solution: Installation Procedure: Prior to installing, download and save the "EIU2003.reg" file attached to this solution. 1. Install Aspen Petroleum Scheduler/Aspen Refinery Multi-Blend Optimizer application as usual (un-install the previous version of the application if you want to install a new version on your m...
Problem Statement: A new routine has been added since build 11.25.25 to help determine the running application. Additionally "AddCase" and "DeleteCase" automation method have been added to Orion.Aplication.
Solution: A routine called "Determine Application" has been added to determine if the running application is Aspen Petroleum Scheduler (APS) or Aspen Multi-Blend Optimize(MBO). Here an example of this Code: New automation methods related with "CASES" funtionality: -AddCase: Use this method to add a new case by copy...
Problem Statement: Can I implement "Calc Units" for an Aspen Petroleum Scheduler(APS) Oracle database?
Solution: Aspen Calc units are supported in Oracle starting with V7.3.0.2. For prior release versions, consider using Excel or OrionVB to duplicate the desired methods Calc Units definition: Calc units are similar to "User-Defined" unit, except that Calc units allow the user to define calculations internally (via the...
Problem Statement: Sometimes a simulation model contains user updated pure component and binary interaction parameters. These parameters can be used in other process models. The steps to create an enterprise database for these parameters are discussed in this document.
Solution: In newer versions of Aspen Plus, you no longer need to make the division of files into DAT and INP, as describe in this KB. Now exporting the DFM file, modifying it and saving it as an INP format is enough to create a new database. If you are using a recent version of Aspen Plus, please refer to How to create...
Problem Statement: Example of the Cause and Effect (C&E) Matrix in Aspen Hysys Dynamics
Solution: The process flowsheet is an example of a simplified process unit with feed cooling and buffer tank, modeled using a Splitter. Cooling is provided by the condenser, PreCon and Feed is delivered to the Process Unit through the Feed Valve. Feed temperature must be kept below 190C or feed to the unit is cut-off, ...
Problem Statement: Within the Integrator, what is the effect of selecting "Reduce recycle efficiency for small timesteps" on the holdup recycle efficiency?
Solution: When the “Reduce recycle efficiency for small timesteps” option is checked in the Integrator Options (and assuming no reactions take place), the holdup recycle efficiency is reduced by the following factor: Factor = min(1, max(0.001, sqrt(Time Step x Composition Frequency/5 seconds))) The Time Step has a ...
Problem Statement: How do I use the SLM Configuration Wizard in V8.8?
Solution: In this knowledge base article we will be looking at the different options inside the SLM Configuration Wizard. To get started we will need to load the SLM Configuration Wizard which gets installed with every product install. Click on Start --> All Programs --> AspenTech --> Aspen SLM --> aspenONE SLM License...
Problem Statement: How to use the SLM Commute Tool for V8.x?
Solution: The Aspen SLM Commute (SLMCommute.exe) allows the user/client to borrow licenses from a network server. These borrowed, or commuted, licenses allow a client computer to run the licensed product while disconnected from the network without the use of a SLM dongle. Note: You must run Aspen SLM Commute when con...
Problem Statement: Can I have both Standalone and Network license on one computer?
Solution: You can configure computers to have both standalone and network modes. For example, if you need to run two AspenTech products: product A is on a standalone license and product B can be accessed from the network. To achieve this configuration, 1. Configure the standalone license on your machine. For this ...
Problem Statement: The PCWS shows this error for a DMC3 application: IOFacilityDataSource.WriteEntries(): Write failed, application 'AKA2'. entry /AKA2/Independent/PIC123.SP/Setpoint value: '10.182'. Write error: status = -6, facility = 77, driverStatus = 77001
Solution: The Aspen Process Controller can request data directly from the OPC server, using Aspen Process Data or CIM-IO. When you add a new IO source you can select the type of connection: We recommend to use CIM-IO as source type and thus the Aspen Process Controller becomes a CIM-IO Client. The executable responsibl...
Problem Statement: When trying to display trends from a data source in aspenONE Process Explorer it displays a message “Timeout occurred before data was retrieved”. Is there any way to get aspenONE Process Explorer to display the data?
Solution: Try disabling the asynchronous calls from the aspenONE Process Explorer (A1PE) server to the remote Aspen InfoPlus.21 servers, to see if this makes any difference to the problem. This involves creating 2 new entries in the registry on the A1PE server. On the A1PE server run regedit. Locate the registry key...
Problem Statement: How to model a compabloc heat exchanger?
Solution: The Compabloc welded plate heat exchanger is constructed by building stacks of rectangular plates into a heat transfer heart. These plates are edge welded to one another to form channels. The liquids flow in cross flow to one another and each side can be configured into the needed number of passes to achieve ...
Problem Statement: How to install, configure, and start V8.8 Aspen Licensing Dashboard on an SLM Server
Solution: This KB article explains how to install, configure, and start V8.8 Aspen Licensing Dashboard on an SLM Server in order to monitor servers for denials, token limits, expirations, etc. For more information on getting started with the V8.8 Aspen Licensing Dashboard, see KB article 142959. Install the required ...
Problem Statement: What is Ramp Imbalance, Programmed Ramp imbalance and Ramp Horizon?
Solution: Ramp Variable - A variable is considered to be Ramp variable when the process parameter either keeps on increasing or keeps on decreasing in value. It never reaches to a steady state. Ramp variable is considered to be at steady state, when the rate of change of the slope for step response curve becomes consta...
Problem Statement: What is the procedure to perform a clean restart of Data Collection in the Aspen Process Controller (RTE) environment? Such a procedure is typically required when the user is unable to edit/update the existing collection list due to the following error: “APC Builder. Unexpected error when submitting...
Solution: - Open a project in APC Builder and extract out all data that has been collected up to this time into this project. This is an extremely important step as the procedure listed in the following steps will result in loss of any data that has not been extracted out. - In APC Builder, navigate to Onli...
Problem Statement: How is Mach number calculated in Aspen Flare System Analyzer?
Solution: The Mach number is defined as: Below is explained how Mach number is calculated using a sample file located in your installation folder "Sample-S1" (also attached to this document). As reference we are using data from BDV Line 1. We know the following information reported in Aspen Flare System Analyzer: Ups...
Problem Statement: Modeling Vacuum Steam Condensers with Aspen Shell & Tube Exchanger
Solution: OBJECTIVE The example file will enable you to setup a Vacuum Steam Condenser rating case in the Shell & Tube Module of the EDR program and help analyze results. PROCESS DESCRIPTION Model a vacuum steam condensation on the tube side using tower water on the shell side. Enable rating / checking mode to evalua...
Problem Statement: Unable to optimize heat exchanger design due to disparate tools for process design, thermal heat exchanger design and mechanical designs, and optimization methods followed by other heat exchanger design tools that are not based on costs.
Solution: Cost based design optimization philosophy followed by Aspen Exchanger design and rating (EDR)softwares would enable you to find the optimal design for your heat exchanger needs based on cost. The seamless integration between the thermal and mechanical design tools of Aspen EDR together with its integration wi...
Problem Statement: What versions of Aspen InfoPlus.21 are compatible when using replication?
Solution: AspenTech recommends upgrading publishing and subscribing replication nodes simultaneously when either: · the replication protocol changes or · there are changes in Aspen InfoPlus.21 records used to replicate data from a publishing node to a subscribing node. When differing versions are comp...
Problem Statement: Refinery utilties planner demo in Aspen Utilies planner (AUP) V 7.3
Solution: Please find the attached zipped file with step by step instructions of typical refinery case in AUP V 7.3 demonstrating new features of Excel embedded data editor and marginal cost. Keywords: Refinery, AUP, Excel, marginal cost References: None
Problem Statement: After applying the Aspen IP.21Process Browser 7.3.0.2 patch a new Web server listed in Microsoft's IIS (Internet Information Service) called PlantData.
Solution: The PlanData Web server is is part of the High Performance Trend feature introduced in IP.21Process Browser with this patch.- It is used with Google Frame to provide fast access to tags in Aspen InfoPlus.21 database when calling the tag search option in the Plot section of IP.21Process Browser. Keywords: Plan...
Problem Statement: New User Interface for Aspen Flare System Analyzer in V7.3 (with viewlet)
Solution: Aspen Flare System Analyzer V7.3 has been significantly improved with a new user interface to improve usability and productivity. The new user interface is based on the latest Microsoft UI technology and standards also seen in Microsoft Office 2007. Improvements include: ? Modern ribbon design that gr...
Problem Statement: How to model heat transfer between two cylinders: Outer rotating (at speed v) while the inner one is stationary.
Solution: Based on the following assumptions : ? vz only function of x. vx= vy=0 ? Steady state The equation of motion of z component of velocity (v) reduces to the following equation : Boundary condition : Using above boundary condition as well as equation of motion, we get the following equation: ...
Problem Statement: What documentation or sample applications exist to help understand and use the new OPC UA feature in V7.3?
Solution: Beginning with aspenONE? v7.3, Aspen provides an OPC UA compliant server-side component known as the InfoPlus.21 OPC UA Server. The attached zip file contains a Help File and sample programs showing how to access data from Aspen InfoPlus.21 using the Unified Architecture (UA) programming interface developed b...
Problem Statement: I installed Aspen PIMS, but it did not seem to install the sample models. Where can I find those?
Solution: The attached file contains the library of Aspen PIMS sample models. These models are usually installed during the regular Aspen PIMS installation process. The typical location for these files is C:\Documents and Settings\All Users\Documents\AspenTech\Aspen PIMS The attached file is a zip of the entire Aspen P...
Problem Statement: How do I Design/Rate/Simulate an Aspen Air Cooled Exchanger in Aspen HYSYS?
Solution: In Aspen HYSYS V2006.5 and later versions, users can use the Aspen Air Cooled Exchanger Design and Rating mode with in HYSYS using a utility associated with the Air Cooler operation. Based on the process information extracted from the Air Cooler, the utility uses Aspen Air Cooled Exchanger program to perform ...
Problem Statement: Is there a sample for a Humidifier-Dehumidifier process?
Solution: The humidification-dehumidification process (HD) is a useful method for water desalination when the demand is decentralized. Although several other techniques are available (distillation, reverse osmosis), this method has several advantages such as flexibility in capacity, moderate installation and operating ...
Problem Statement: How can I model a water boiler with combustion on one side in Aspen Plus?
Solution: You can use a reactor block (RSTOIC in this example) for the combustion reactions. Take the hot outlet from the reactor and feed it to a heater block connected with an energy stream to another heater block where water is fed. An example file is attached . A Design-spec is included that fixes the combustion ga...
Problem Statement: Sample file for CO2 capture using K2CO3 using Aspen HYSYS (ELECNRTL)
Solution: Refer to the attached Aspen Plus backup file, PDF documentation and the Aspen HYSYS file. Note: 1. Aspen Properties ELECNRTL is used to model it within Aspen HYSYS. These features are new to Aspen HYSYS. Users can open the attached file in V7.3 and later only. 2. The HYSYS file predicts close results with Asp...
Problem Statement: How do you regress solubility data for a salt such as Na2SO4 that forms different hydrates at different temperatures?
Solution: The salt are regressed separately. Aspen Plus can handle multiple hydrates. Attached is an example of regressing solubility data for Na2SO4. From 0 C to 30 C, the hydrate with 10 water molecules (Glauber salt) forms. From 40 C to 100 C, the anhydrous salt forms. The following data is from Perry's Chemical Eng...
Problem Statement: I am working on liquid liquid extraction of clarified slurry oil to produce de-aspahlted oil by removing asphaltene using pentane as solvent but I am having problems defining key components when using an assay or blend by defining boiling curve data.
Solution: The following solution provides the necessary steps for defining key components from an assay or blend using boiling curve data. 1. Start a new simulation using the metrics template from the Aspen Plus User Interface menu. 2. In the components list create a list of the components you will use within the sim...
Problem Statement: The enthalpy of a stream in Aspen HYSYS is calculated by three parts: The ideal gas enthalpy, the enthalpy basis offset and the enthalpy departure. The description of the calculation for these parts is presented on solution 108891. For a better understanding of these calculations, this solution docum...
Solution: Solution 108891 shows that the parts for the calculation of the enthalpy of a stream are 1. Ideal Gas Enthalpy 2. Enthalpy Basis Offset 3. Enthalpy Departure The attached HYSYS file (Enthalpy calculation.hsc) includes a methane stream at 122A? C and 50 psia. The detailed calculations are included on the a...
Problem Statement: Compute Isentropic Expansion Coefficient Using User variable in Aspen HYSYS.
Solution: Aspen HYSYS could not directly report Isentropic Expansion Coefficient, k. Based on the equation Definition: -V/P(dP/dV)T*Cp/Cv, we could get numerical derivative of dP/dV at equal temperature condition. Mole volume and Cp/Cv are reported in Properties page at actual condition. You can calculate the Isentropi...
Problem Statement: Aspen HYSYS SQP Optimization - A Practical Guide
Solution: Aspen HYSYSTM SQP optimizer uses a steady state simulation of the process built using HYSYS software. There are a number of optimization algorithms in Aspen HYSYS. This document only focuses on the Hyprotech SQP method. This document provides information for the following: ? Those wishing to gain basi...
Problem Statement: How to regress solubility data for Na2CrO4 at different temperatures.
Solution: Attached is the example of regress solubility data for Na2CrO4 at different temperatures. Data is taken from Perry's Chemical Engineering Handbook from the section Physical and Chemical Data. T Na2CrO4.10H2O Na2CrO4.4H2O 0 31.7 10 50.17 20 88.7 30 88.7 40 95.96 50 104 60 114.6 In the component...
Problem Statement: New in V7.3 - Usability Improvements and New Example Cases for Rate-Based Distillation in HYSYS
Solution: The use of rate-based distillation models for sour gas cleaning applications was first introduced within Aspen HYSYS in V7.2. V7.3 introduces improvements in both its usability and new industrial-scale example models for a variety of amines. Easier Accessibility of the Rate-Based Distillation Unit Operation M...
Problem Statement: New in V7.3 - Create a GOSP Model Using the Conceptual Design Builder - Advanced Features
Solution: V7.3 introduces the Conceptual Design Builder tool within Aspen HYSYS. The Conceptual Design Builder allows a user to quickly build a steady-state HYSYS model of a gas-oil separation plant (GOSP). Data for the reservoir fluids and process design preferences are entered in a series of templates within the Conc...
Problem Statement: Customers reported Aspen Infoplus.21 crashing with the following error: Usually this error occurs when Aspen InfoPlus.21 Access Service is not running in Windows services.
Solution: 1. Bring up Microsoft Windows Services Console by pressing the ?Windows Key? + the ?R? key, type services.msc and hit Return key 2. Check if the Service is running, if it's not, start it 3. To prevent it from stopping automatically, you can set the 'Recovery' tab of the service to restart on s...
Problem Statement: Installation of MS .NET Framework 4.0 changes the PathWWWRoot Registry keys to the default C:\inetpub\wwwroot which causes Aspen IP.21 Process Browser to stop working for those customers who install their IIS server on the drive other than C:\.
Solution: To resolve this issue, you must manually change the PathWWWRoot Registry keys to point to your actual IIS location. Keywords: None References: None
Problem Statement: What are the units associated with setVariableValues and getVariableValues on the Aspen Custom Modeler OLE interface?
Solution: The units associated with this pair of functions are not documented in online Help. When setVariableValues is called from a client application, variable values are passed from the client application to ACM. The values have to be in internal units. When getVariableValues is called from a client application, va...
Problem Statement: Are any CAPE-OPEN examples available? Some of the older CAPE-OPEN projects no longer compile.
Solution: Starting in V7.2, we will not be providing example CAPE-OPEN models. We recommend that customers go to http:\\www.colan.org for example CAPE-OPEN models. Keywords: None References: : CQ00405788
Problem Statement: What are the units associated with setVariableValues and getVariableValues on the Aspen Custom Modeler OLE interface?
Solution: The units associated with this pair of functions are not documented in online Help. When setVariableValues is called from a client application, variable values are passed from the client application to ACM. The values have to be in internal units. When getVariableValues is called from a client application, va...
Problem Statement: Is it possible to open V7.3.2 files in earlier versions?
Solution: Even though it was possible to open V7.3 files in V7.2, it is not possible to open V7.3.2 files in earlier versions. This is due to a section in the backup file that starts $_APWNSHELL_SETTINGS. If this section is removed by editing the backup file as a text file, the file will open though new features will b...
Problem Statement: When running the same file in V2006.5 and V7.3, there are different results for the RadFrac distillation column block reboiler temperature. In V2006.5, the temperature is 89.4°C and in V7.3, without any input change, the value for the reboiler temperature is 90.7°C. When simulating a reboiler, 1°C of...
Solution: We made some changes to the thermosiphon reboiler, which caused different results between 2006.5 and V7.3. When the return liquid from the thermosiphon reboiler is mixed with the liquid from the last stage, there might be some vapor generated from the mixing. This is not considered in 2006.5, but was taken in...
Problem Statement: When I open a xlsx spreadsheet in Excel with the Aspen Process Data Addin loaded I receive the error message "Excel found unreadable content in xlsx document" and when I click through to open the document any charts I had created are not displayed.
Solution: This issue has been reported and is under investigation under CQ00447669. It has been noticed that this problem is linked to the use of a "," comma separator within the regional settings of the operating system. If you change this to a "." full stop then the problem is no longer witnessed. Keywords: Excel fou...
Problem Statement: Why codes like BLOCKS("FLASH_LC").PV.isConnected does not work in Newer Aspen Plus Dynamics?
Solution: We no longer support coding structure such as BLOCKS("FLASH_LC").PV.inputvariable.isConnected in script for control signal variables for version V 7 and onwards. Please change it to: BLOCKS("FLASH_LC").PV.isConnected) to get the expected behavior. In the older version, we used to support former coding structu...
Problem Statement: Incorrect inventory calculation in Aspen Adsorption.
Solution: We have found a discrepancy in the inventory calculation. The values currently calculated in V7.3 should be: Gas inventory: correct value is the displayed value multiplied by the total voidage (Eb). Adsorbed inventory: correct value is the displayed value divided by the total voidage (1-Eb). Keywords: Voidage...
Problem Statement: This Knowledge Base article shows the basic steps for how to set up the Aspen Excel Add-in V7.3 service for publishing to MS SharePoint 2007 (MOSS 2007).
Solution: Please download and review the attached document titled: ExcelAddin_MOSS_User_Guide.docx Keywords: Excel Add-in User Guide Addin References: None
Problem Statement: AspenTech SQLplus ODBC driver를 시스템 DSN (system DSN) 에 추가한후 Microsoft Excel 2007 에서 DSN를 이용하여 데이터를 import 하려면 아래와 같은 오류 발생:
Solution: 본 오류는 데이터 연결 마법사( Data Connection Wizard) 때문에 발생하는 문제입니다. 데이터 연결 마법사는 OLEDB provider를 사용하는데 SQLplus 는 ODBC provider만 사용이 가능합니다.ODBC provider를 사용하여 InfoPlus.21의 데이터를 성공적으로 Import하기 위하여 Microsoft Query를 대신 사용하여야 합니다. Microsoft Query를 사용하기 위하여 아래와 같은 작업이 필요합니다. 1. 데이터 탭 클릭 2. 기타 원본 (From Other Sources) 클릭 3....
Problem Statement: Installing Aspen SCM Patch 6. Where are the shared library files located?
Solution: There are no libraries for SCM Patches. Shared libraries are installed only for CAPS and not Aspen SCM. Keywords: None References: None
Problem Statement: You are trying to install Aspen SCM via the .MSI file on the installation disk on a Vista or Windows 7 operating system. How is this done?
Solution: Installing Aspen SCM directly from the .MSI file is not supported and will not work for the Vista or Windows 7 operating systems. However, you can use the .MSI to install via the Aspen Silent Install or 3rd party distribution software. To use the .MSI file via Aspen Silent Install or 3rd party distribution so...
Problem Statement: When I try to change my screen resolution to 1680 X 1050 or 1920 X 1200, the settings do not take. The current setting field will display the setting I want but the in the table display (lower part of the screen) the current resolution displays something different.
Solution: Aspen SCM Configured Applications (CAPs) support the four following screen resolutions: 1024 X 768 1280 X 1024 1400 X 1050 1600 X 1200 All control positions (buttons, option menus, labels, etc.) and size (Geometrics) are based on these 4 resolutions, which are defined in the SCRGEOM table. Keywords: Screen ...
Problem Statement: How can I make one set equal to another in Aspen SCM?
Solution: Use the following efficiency trick for making one set equal to another: Instead of this: SET1 = 0 SET1 = SET2 Use this: GETCAT &1 = SET2 COUNT SET1 = 0 SET1 = &1 FILL SET1(,C) = SET2(,C) FILL SET2(,D) = SET2(,D) Keywords: None References: None
Problem Statement: My rule/macro is returning the message "end of set with no condition". What does this mean?
Solution: The "end of set with no condition" is a result of a rule which is incomplete. The easiest way to identify the problem is to run a debug on the particular rule or macro that is failing. To run a debug in MIMI, simply place an exclamation mark (!) in front of the statement you want debugged on the command line....
Problem Statement: If I have a problem typing in Chinese characters in activity editor in Aspen SCM running on Citrix, how do I resolve this?
Solution: This is window locale setting related issue. To save/display Chinese char in SCM(CAPs) , user needs to change his/her Windows Locale to ?Chinese (PRC)?. (Picture 1) After that, you can save Activity Editor fields with Chinese. (Picture 2) Picture 3 below is to set ?Facility? modifiable in AEOMFG. Keywords: ...
Problem Statement: As a part of Server Auding and hardening the server, you are tasked with disabling/removing settings which are not required. Does the ` Sentinel RMS License Manager? service require the `Allow Service to interact with desktop? setting? .
Solution: The only supported configuration for this service is to retain the "Interact with Desktop" feature enabled. Disabling could potentially cause issues. Keywords: None References: None
Problem Statement: I get the error message "the view could not be created for one of the......" when I am displaying two workspaces. How can I resolve this?
Solution: Close the first workspace before you display the new workspace. You can close the workspace via the DESTROY command. example: DESTROY $GUI Keywords: None References: None
Problem Statement: What's New in Aspen Shell & Tube Mechanical V7.3 - Horizontal support design per ASME 2010 Div 2 Part 4.15
Solution: Aspen Shell and Tube Mechanical V7.3 contains the support-induced shell stress analysis (Zick) calculation per ASME Division 2 part 4.15, Design Rules for Supports and Attachments. This calculation provides for a published well documented design procedure not yet available in Division 1 for the evaluation of ...
Problem Statement: When attempting to start the Aspen Security Web Server console, the page fails to display, and an error message like the following is displayed: Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the...
Solution: To troubleshoot this issue, Microsoft's Procmon tool was used. In the Procmon log, when the website was opened, an Access Denied for the w3wp.exe process was shown. Checking the Properties of the event, the w3wp.exe process, running under the NT AUTHORITY\NETWORK SERVICE account was the process getting denied...
Problem Statement: What's New in Aspen Shell & Tube Mechanical V7.3 - ASME 2010 Code and Material properties Update
Solution: Aspen Shell and Tube Mechanical has been updated with the 2010 ASME code and materials update. New materials were added and obsolete materials were deleted. The code and material standard year is shown as follows: Keywords: ASME 2010, Code, Material properties, Update References: None
Problem Statement: Aspen Framework / Aspen Local Security locks up on multiple cpu systems. The lockup causes poor performance for the applications, such as the Production Control Web Server.
Solution: Replace the current afwsecclisvc.exe in the AspenTech \ BPE directory with the one attached to this solution. Steps: (1) Open Services from Control Panel (2) Right mouse click the service ?AFW Security Client Service? and select Properties (3) Click the Stop button and stop the service. (4) Change Sta...