Problem Statement: Sometimes I get a message about a missing DHFORM or DHAQFM in a reactor, but sometimes I do not.
** ERROR
PHYSICAL PROPERTY PARAMETER DHFORM OR DHAQFM IS MISSING FOR H4SIO4.
ABSENCE OF THIS PARAMETER WILL RESULT IN INCORRECT ENTHALPY CALCULATIONS.
Problem OCCURRED WHILE FLASHING OUTLET... | Solution: The missing parameter check is made when the specie amount is changed by more than 1e-8 kmol/s. On some sensitivity rows, the change is just above that causing the check and the error. The amount of 1e-8 is applied to absolute difference as it is pretty small, and a relative amount check could cause such smal... |
Problem Statement: I am developing my Aspen Properties application using the option you suggested: Multiple Property Methods. I can see that I can retrieve the currently active (global) property method OPSET name by calling PPUTL_GOPSET. But, I cannot find a way to
(1) Determine how many Property Methods were sp... | Solution: Here is an undocumented subroutine PPUTL_LSOPST that you can call to determine the number and names of the Property Methods specified in a simulation..
CALL PPUTL_LSOPST(KOPS, NAME, IST, INUM )
VARIABLE I/O TYPE DIMENSION DESCRIPTION AND RANGE
KOPS O I - ... |
Problem Statement: I have a Hierarchy block in my simulation. Is there a way that I can move everything inside into the main flowsheet? | Solution: You can right-click on the Hierarchy block select Move selection.
You can use the Extract hierarchy contents and delete option. Clicking on OK will prompt you to resolve ID conflicts if there any. Ater you resolve conflicts, all the objects will be transferred into the main flowsheet.
Keywords: Hi... |
Problem Statement: I was able to define conversion and selectivity through the Calculator block. By using Fortran Write statements, the results are printed in control panel. I was wondering if I can print the output on the flow sheet itself so I won't need to go to the control panel every time I want to check the value... | Solution: You can put the values on the flowsheet using a Custom Table created by clicking on the icon on the Customize ribbon. If you assign a parameter variable to the calculated value, you can place the Define variable result a custom table. The table can be placed on the flowsheet or viewed as a form. In the attac... |
Problem Statement: You are unable to add records or folders in the Infoplus.21 Administrator and receiving the error 'Invalid Sever Index 0 was specified after using RECLOAD to add records to your snapshot. | Solution: This problem occurs when you are using the utility RECLOAD to add records to your snapshot and the number of records surpasses the number of free records in the Infoplus.21 database.
To resolve this issue you will need to increase the number of Total records you have in the Record Utilization tab.
1. In the I... |
Problem Statement: After successfully installing IP.21 version 3.1, two error messages appear while trying to add a new InfoPlus.21 group. First an Access Denied. message followed by Error while attempting to unregister the security repository for the old group. | Solution: The first step is to check DCOM permissions. To do so, go to Start | Run | dcomcnfg. In the DCOM configuration window, under the Default Properties tab confirm that the default authentication level is Connect and the default impersonation level is Identify.
If DCOM already contains these properties, it may be... |
Problem Statement: Microsoft SQL Server installation fails when installed after aspenONE products.
Some Microsoft SQL Server components are installed along with several AspenTech products. Including: Aspen PIMS, Aspen InfoPlus.21, Aspen Operations Reconciliation and Accounting, Aspen Tank and Operations Manager, Aspe... | Solution: 1. Go to Program and Features.
2. Uninstall Microsoft SQL Server Native Client.
3. Install Microsoft SQL Server.
Note: Microsoft SQL Server Native Client will be reinstalled along with SQL Server.
Keywords: Express, SQL, installation, order
References: None |
Problem Statement: How have timestamps changed? What is the re | Solution: , how is it processed, and what will I see in my client applications?Solution
In considering this information it is helpful to note that the IP.21 real-time database is separate from the IP.21 historian.
Millisecond reSolution is new to the IP.21 real-time database in version 3.x. However, even in previous ve... |
Problem Statement: This Knowledge Base article answers the following question:
Why every four minutes TSK_DBCLOCK sends the following message to the license server:
IP21ServerUpdateLicenseState - *X_GetIP21ServerLicenseState*
The message can be seen in the TSK_DBCLOCK.OUT file when VERBOSE logging is enabled. | Solution: The communication between the TSK_DBCLOCK and the license server is the heartbeat to ensure the database is still in contact with the License Server.
This “heartbeat” message cannot be disabled or its frequency changed.
To remove the messages from the TSK_DBCLOCK.OUT file, switch off VERBOSE logging, and rest... |
Problem Statement: The TSK_API_SERVER task might die immediately after an IP.21 database startup. Even after the most recent TSK_API_SERVER executable file has been installed (ER #990830A) and NobleNet Portmapper is running, the task may still die, and the TSK_API_SERVER.ERR log file shows an invalid IO handles, exitin... | Solution: In the InfoPlus.21 Manager, the Input File field for the TSK_API_SERVER task MUST have nul: filled in for that field. This field normally would default to nul: after the installation of the IP.21 system. However, this field may accidently get blanked out by a user and will cause the TSK_API_SERVER task to die... |
Problem Statement: Aspen InfoPlus.21 fails to start and DBCLOCK.OUT shows the following error message:
IP21Subscription shared memory already created by some other process - exiting | Solution: Is some rare occurrences, AspenCalc may not release the Aspen InfoPlus.21 shared memory during shutdown. This problem may be resolved by restarting the Aspentech Calculator Engine service and starting Aspen InfoPlus.21 again.
Keywords: IP21SUBSCRIPTION
shared memory
AspenCalc
References: None |
Problem Statement: ScheduledActDef records are used to activate other records in the database on a regular, scheduled basis. A single Scheduling record has one schedule time and reschedule interval but it can activate (process) multiple records in the database. The records to be activated are entered in to the repeat a... | Solution: The following shows the Fixed Area of a ScheduledActDef record.
Currently, the new record has nothing to do because the field #DATA_BASE_RECORDS is 0. To have this record schedule other Aspen InfoPlus.21 records, enter a positive integer into the field and expand the repeat area.A Enter the records to be sche... |
Problem Statement: When installing or upgrading to a newer version of InfoPlus.21 database, the Aspentech DEMO database is loaded by default. If you don't want this to happen, follow the steps below to get rid of the DEMO database. | Solution: -- stop your database if it's currently running
-- in the Group200 directory (located in
<drive>:\Program Files\AspenTech\InfoPlus.21\db21\Group200) delete the newly created snapshot called InfoPlus21.snp
-- go to the etc directory, and copy the virgin snapshot called InfoPlus21DB.snp and paste it into the Gr... |
Problem Statement: When a IP21HealthDef record belonging to the CIMIOHealthTests group is activated its ERROR? field will be YES if it does not pass all tests. The #STATEMENTS repeat area lists the reasons why the test may have failed. But what needs to be done if the message recorded is:
Health Test Problem - Invalid ... | Solution: IP_LIMIT_DEADBAND must be ????????? since a number in this field is invalid.
Simply type ? key and RETURN key if you have mistakenly put a number here.
You should also make sure that the RECORD_&_FIELD_NAME field is correctly specified. If this field is blank then ERROR?=YES although #STATEMENTS will indicate... |
Problem Statement: How to resolve the following error when trying to open Aspen InfoPlus.21 applications after a new install -
The procedure entry point IP21GetSharedDisk could not be located in the dynamic library libc21.dll | Solution: If a machine has had older Aspen InfoPlus.21 products installed before and clean uninstall was performed, sometimes files can remain on the server. Do a search for the libc21.dll as referenced in the error message. If the dll exists in two locations, delete the file that does not reside in
C:\Program Files (x... |
Problem Statement: Relational Database Error -2147217900 Invalid column parent_char_id.... Batch characteristics don't show up in the Batch.21 Administrator. Batch areas won't appear in BCU Administrator. Characteristics will be empty from wherever you try and view them. | Solution: You will get this error message if you upgrade the Batch.21 software from 6.0.1 to 2004.x or higher, 2004.1 and you forget to upgrade the Batch.21 database. Several new columns were added with Version 2004 of Batch.21 including the Parent_Char_ID field in the Characteristics table. Since this column name does... |
Problem Statement: After installing IP.21 v3.1 the local IP.21 node is not listed in the IP.21 administrator. | Solution: Remove the data source in the ADSA config tool and re-add it.
Sometimes you also have to reboot the PC.
Keywords: administrator
References: None |
Problem Statement: How do I prevent Aspen IP.21 Administrator from crashing when tryting to create new tag by right clicking on folder? | Solution: On some specific InfoPlus.21 Snapshot it’s observed that when trying to create a new Tag by right clicking on a Folder, IP21 Administrator will get freeze and then crashes.
This issue is due to incorrect value configured in “Folder_links� for that particular folder.
Please follow below steps to upda... |
Problem Statement: Generally an event.dat file is created when the history process, h21archive.exe, is paused or stopped due to file set backups or history system problems. However, there have been cases where an event.dat file is created while the h21archive process is still running. This can happen if data is enterin... | Solution: 1. Check the fragmentation of the hard drive storing the history file sets. Chances are, this drive is badly fragmented, thus creating a performance bottleneck. Data is being collected faster than the history task is able to write to disk. You will need to stop IP.21 and run a defragmentation utility.
2... |
Problem Statement: ghost field를 추가할때 아래와 같이 드롭다운 목록에 내용이 없음. | Solution: 본 이슈는 ghost field로 추가할 field가 이미 custom definition record에 추가되였기 때문입니다.
1) offending field 삭제
2) fixed area에서 아무 field 나 클릭
3) 메뉴 바(menu bar)에서 Fields 클릭
4) New | Ghost Field를 선택하여 New Ghost Field 창을 오픈.
5) Ghost Selector, Ghost Record 와 Ghost Field 를 선택
6) 확인를 클릭하여 Ghost Field 를 custom definition record에 추가
... |
Problem Statement: When launching the Health Monitor from the Aspen InfoPlus.21 Administrator, the IP21 Tasks Health Tests expand to show three fields, but not the field titled IP21 License Tests. | Solution: Navigate to IP21HealthGrpDef and locate IP21TasksHealthTests from that definition record. Make sure the #DATA_BASE_RECORDS field is set to 4 and open the repeat area. Make sure the 4 record names there are: AllIP21TasksRunningTest, IP21TasksReStartingTest, AllIP21ServicesRunTest, and IP21LicenseTests as follo... |
Problem Statement: Upon trying to start Aspen InfoPlus.21, TSK_DBCLOCK never gets started and there is an error in the TSK_DBCLOCK.OUT file that reads The timestamp in one of the cache.dat files does not match that of the snapshot. | Solution: This issue may occur due to corruption in either the database snapshot, the cache.dat file associated with one of the repositories, or the file sets within the repositories reporting an invalid timestamp. There are three knownSolutions that have been used to resolve this problem:
1. When starting Aspen In... |
Problem Statement: The find references tool in IP.21 administrator is not working and throws the following error message:
Type System.Threading.Tasks.Task1[AspenTech.InfoPlus21.Access.Contracts.TagldentifiersByDefinitionTag]’ cannot be serialized. Consider marking it with the DataContractAttribute attribute, and mark... | Solution: This issue can be resolved by reinstalling Microsoft .Net 4.5.2
Keywords: Show references
Type System Threading Tasks
References: None |
Problem Statement: Why does the snapshot size increase after upgrading to V7.3? | Solution: During an upgrade process from earlier versions of Aspen InfoPlus.21 to V7.3, there will be a point in time where space is needed for the new variable length name segment that provides for the increase of the 24-character name space in the record to 256 characters. Because of this, upgrade needs a lot of spac... |
Problem Statement: This is listed as step #2 on page 22 of the InfoPlus.21 Database and History Migration manual. Migrating data (i.e. adding more points) to InfoPlus.21 from another IP.21 node or CIM/21 using Aspen''s ASCTOARC conversion program could produce the following error message:
find_cache () free pointer cor... | Solution: Check the ''number of points'' configured for the repository on the migration system. You may need to increase this number for the migration program to behave. Although the code is supposed to handle when the configured ''number of points'' is less than the number of points in the migration file, it is still ... |
Problem Statement: If you are experiencing communication problems between InfoPlus.21 OPC DA Server and an OPC client, then a log file for the OPC server could be helpful. Is such a log file generated? | Solution: A log file called IP21OPCServer.log is generated by the InfoPlus.21 OPC DA Server. This log file will created the first time that a message is produced that matches the filter criteria. The log file can be found at:
C:\ProgramData\AspenTech\InfoPlus.21\db21\group200\IP21OPCServer.log
The filter criteria for... |
Problem Statement: When creating SQLADef tags, users might want to set the value of the IP_STEPPED field to either Interpolated or Stepped to use this setting as a default for Process Explorer (checked on unchecked Stepped column). However, in order to accomplish this task, the map record for SQLA tags (IP_SQLAMap) mus... | Solution: To modify the SQLA map record, follow these simple steps:
1. Locate IP_SQLAMap, defined by AtMapDef.
2. Set the filed MAP_#Maps to 1 to add an occurrence.
3. Go to the first occurrence and add 'STEPPED' to Map_Attribute and 'IP_STEPPED' to MAP_FieldName. This step allows IP_SQLAMap to match t... |
Problem Statement: 왜 rate-based distillation column 플래시계산에서 온도가 서로 다른가? | Solution: Rate-based stage에서 증기성분과 액상성분은 상평형을 이루지 않는다. 기액상평은 오직 경계면에서만 발생한다고 가정하기에 이를 화학평형으로 볼 수 있다. 때문에 rate-based stage에서는 플래시 온도가 다를 수 밖에 없고 출구유체에서 기액상평형과 화학평형을 이루어질 수 없다.
Keywords: None
References: : CQ00357921
Please find |
Problem Statement: If I have to repair file sets from many repositories, can I run multiple copies of H21ArcckWizard.exe (History Arc Check Wizard) at the same time? | Solution: If you have to repair file sets from multiple repositories, you can start concurrent copies of the history archive checking wizard (H21ArcckWizard).
Keywords: repair file set
References: None |
Problem Statement: Listed here are the two most likely occasions when you might see the error:
Licensed Point Count must be 'nnnnnn' Minimum
(where 'nnnnnn' might be any number between 1 and 2097151)
You might see this in the Output file for Loaddb when the Aspen InfoPlus.21 startup fails at loaddb.
Another time mi... | Solution: Shutdown the Aspen InfoPlus.21 database if it is currently running - the problem cannot be solved with it running.
From the Left hand pane of the Aspen InfoPlus.21 Administrator, under InfoPlus.21, right click on the name corresponding to the database in question.
Choose Set Point Count
It is the number seen ... |
Problem Statement: How do I check the license status on my Aspen InfoPlus.21 server? | Solution: The License Status tab displays the current status of the InfoPlus.21 server.
To view license information:
1. In the InfoPlus.21 Administrator, right-click the InfoPlus.21 database and select Properties from the context menu.
2. On the Database Properties dialog box, click the License Status tab. The... |
Problem Statement: How does Aspen InfoPlus.21 use the field FIELD_NUMBER (hex) in records defined by FieldNameDef and FieldLongNameDef? | Solution: Aspen InfoPlus.21 uses records defined against FieldNameDef and FieldLongNameDef to create data field names for Aspen InfoPlus.21 records. The only difference between data field names defined against FieldNameDef and FieldLongNameDef is the maximum length of the data field names defined against them. Data f... |
Problem Statement: How can I delete a file set to recover disk space without first stopping Aspen InfoPlus.21? | Solution: Aspen Technology strongly recommends stopping Aspen InfoPlus.21 before deleting the contents of file sets (arc.dat, arc.key, and arc.byte); however you can following these steps if it is not possible to stop Aspen InfoPlus.21.
1. Open the Aspen InfoPlus.21 Administrator and stop the repository with the file... |
Problem Statement: TSK_DBCLOCK hangs at 50% during startup, then quits. Error messages found in TSK_DBCLOCK are:
h21_arck_local failed with ret = -1040
CreateFile failed
The problem appears to be related to the history filesets. For V7.1 and later, a new utility exists that attempts to validate the path to each fil... | Solution: In this case customer had run h21chgpaths.exe to change the UNC path for all the filesets in config.dat. Since the directory structure was unchanged on the new server, the change of nodename in config.dat seemed to be enough. However in addition to the fileset locations, config.dat also specifies the reposito... |
Problem Statement: When using standard IP_AnalogDef records, normal behavior is that values written to the IP_INPUT_VALUE field will propagate to the IP_VALUE field, and then be written to history. You might see a situation where the values updating in IP_INPUT_VALUE do not propagate to IP_VALUE. | Solution: One possible cause of this behavior is that compression is activated for the record. If this is not the case then there could be a problem with the IP_BoxcarSlope record. The IP_BoxcarSlope record must be configured for data to propagate from IP_INPUT_VALUE to IP_VALUE even though compression is not being use... |
Problem Statement: This knowledge base article explains how to remove duplicate tasks from the Aspen InfoPlus.21 Manager defined task list. | Solution: Duplicate tasks can appear in the Aspen InfoPlus.21 Manager task list when there is more than one task registered in the registry with the same order number. Try to remove the extra task using the 'Remove' button. If that does not work go to the following location in the registry:
32 bit systems :-
HKEY_LOC... |
Problem Statement: The example for INSOCCS in the manual is for inserting new occurrences into history. The following example shows how to do this for a non history occurrence such as ENG-UNITS. | Solution: NOTES: modify the #define for ARRSZ for the number of occurrences to insert, INSERT_AT for the occurrence number to begin inserting, the recid variable for ENG-UNITS on your system and the description array values for the actual units to write.
#include <stdio.h>
#include <stdlib.h>
#include <string.h>
#inclu... |
Problem Statement: Users who develop large custom applications which rely on Aspen Batch.21 data prefer to use the fastest method of data retrieval possible to optimize performance in their custom applications. This knowledge base article describes which method of data retrieval is faster. | Solution: Assuming the user interacts with the Aspen Batch.21 API and the web service identically the performance will be faster in the Aspen Batch.21 API as the web service is just an extremely thin wrapper around the API datasource's XML method. If the web service is used, the application will see the performance imp... |
Problem Statement: I am using a transfer block to copy a stream, why does Aspen Plus say that the input for the stream I am trying to transfer to is incomplete? | Solution: If you want to transfer stream S1 to stream S4, you can do this by adding a Transfer block, like in the following screenshots:
However, the flowsheet input is incomplete, and I won’t be able to run the simulation.
To fix this, input any values in the stream S4 Input form. These values will not be used for the... |
Problem Statement: By default, Aspen Plus uses the ideal gas enthalpy to calculate the pure component vapor and liquid enthalpies. There are instances that the user may need to use liquid based enthalpies for the simulation and values obtained from the default Aspen Plus setting would not be right. There are options av... | Solution: ID 3100). These techniques have the drawback that the enthalpy calculations will be liquid based for all the components in the simulation which obviously will be incorrect for gaseous components.
Solution
In situations where the user needs to selectively specify the liquid reference state for a component in a... |
Problem Statement: Several aspenOne Manufacturing Suite products contain an embedded Aspen InfoPlus.21 license. | Solution: The following products contain an embedded Aspen InfoPlus.21 License (pre-V7.1 name between parenthesis) :
Aspen Nonlinear Controller (Aspen Apollo Online)
Aspen PID Watch Performance Monitor (Aspen PID Watch)
Aspen Polymer Production Control Online
Aspen Process Controller (and variants)
Aspen RTO Watch Perf... |
Problem Statement: TSK_H21_PRIME may not start successfully. The task itself may stop with an error 1 and the following will appear in the output or error file:
Message Can NOT Be Found: -2506
What is causing this problem and what can one do to correct it? | Solution: This problem is caused because the tasks in the 'Defined Tasks' list have been moved out of their proper order. In aspenONE 2006.5 there are fewer important startup tasks (and the order of the remaining ones has changed). Here is an excerpt from the 2006.5 Aspen InfoPlus.21 Release Notes:
Consolidation of M... |
Problem Statement: Having a custom record with more than one historical repeat area, it is possible to use AtMapDef record to create trend plots of the values for each repeat area. This | Solution: provides an example of the configuration of the AtMapDef record needed for this as well as the consideration while building the custom record to properly work for it.
Solution
For this example we're going to use a custom record defined as follow:
in which CST_TrendValuesArea represent the historical repeat ar... |
Problem Statement: In the Aspen InfoPlus.21 Administrator, the record utilization tab of the database displays two properties.
Records and Licensed Points.
The utilization of both the properties is displayed in the Record Utilization Tab. As both the properties are essential in interpreting the database utilization,ve... | Solution: The total number of Licensed Points in an InfoPlus.21 database equals the number of records with history repeat areas. Whereas, Records group box displays the number of available records in various states.
For example, based on the screen shot below,
Total number of records with History Repeat Areas- 438
T... |
Problem Statement: In some cases, when opening the InfoPlus.21 Manager after an install or upgrade, there are no tasks appearing in the Defined Tasks list. As such, AddGroup.exe will need to be run following the instructions in | Solution: id 108434.
However upon running the AddGroup.exe executable, the following error messages is encountered as per the screenshot below.
Solution
In this case, perform the following steps:
1. Launch Windows Task Manager.
2. Click on the Processes tab.
3. Sort by Image Name.
4. Look for orphaned d... |
Problem Statement: Using the IP.21 v3.1 Administrator tool, an IoGetDef record is selected. If the Properties of that record are selected for viewing, the Administrator utility crashes with a Dr. Watson error. A document depicting the error has been included as an Attachment to this Tech Tip. | Solution: Install InfoPlus.21 v3.1 Service Pack 1. Installing Service Pack 1 for InfoPlus.21 v3.1 resolves this problem. This was not mentioned in the SP1 release notes. This Service Pack is downloadable fromSolution #104117.
Keywords:
References: None |
Problem Statement: What does the number (50) mean when I try to activate a record manually in the IP.21 Administrator? | Solution: This is a priority setting, related to the external task that runs the activation. All external tasks are assigned a priority and when more than one record tries to use it at the same time, the higher Activation number, the higher the priority the record has, so the sooner it will execute. Most of these prior... |
Problem Statement: What are some general guidelines for applying replication when using custom definition records? | Solution: 1. Each Aspen InfoPlus.21 system (publishing and subscribing) must be at the same patch level.
2. The custom definition record must exist on both the publishing and subscribing systems.
3. Pre-version 11 only: You can only replicate fields located in the fixed area of a record. You cannot replicate repeat... |
Problem Statement: Project won't start up when Office 2007 is in place
For example, a typical error is that engine fails to start up even though the steady state detection starts up just fine. | Solution: Access 2007 requires trusted locations to be configured to allow access to the Access database file. The Aspen OnLine project folder should be added to the trusted location list. To do so:
1. Run Access 2007
2. Click on the Office button on top left corner and select Access Options button at right bottom corn... |
Problem Statement: Need to copy data directly from Process Explorer into an Excel file. | Solution: For 2.5.x
Zoom the plot to set the data you want to retrieve. Note that all the data for the displayed timeline will be copied. Highlight the tag of interest.
Right-click to display the context menu and select Copy.
A new window, Enter Delimiter, appears and provides the options of Tab, Comma and Space. Space... |
Problem Statement: There is a message in the STATE field that RTO is DOWN DUE TO FAILURE. | Solution: Sometimes this problem can be caused by a locked or corrupted history file (hist.dat) in the \HIST folder, which prevents the Online system from running through its cycle.
This type of problem can often be resolved by:
Stopping the RTO program
Issuing the ?histdel? command via a Simulation Engine window, wh... |
Problem Statement: Do we have any restrictions on the number of characteristics a batch can have in Aspen Production Record Manager (formerly called Aspen Batch.21)? | Solution: There are no limitations to the number of characteristics you can have for the batch .
Keywords: Limit
Characteristics
Batch
References: None |
Problem Statement: This article describes the reason why the Process Explorer legend and the Process Data Add-in can return the value of
Unknown Status (-32768)
for the quality status when the quality status data is requested for a custom record. A procedure to fix this problem by modifying the definition record is als... | Solution: The root cause of this problem is an incorrect association of the quality status field within the history value field of the custom record.
When looking at the properties on the history status field in the Definition Editor for a working IP_AnalogDef record, one notices that the history status field lists QUA... |
Problem Statement: This knowledge base article describes how to work around the following error
Cannot load Aspen Process Data XLA resources! Please try reinstallation
which can be observed when attempting to load the Aspen Process Data add-in into an Excel worksheet. | Solution: 1. Versions 2004.x are dependent on a resource file named AtProcessDataXLAResources.dll. This file should be located in this folder:
Program Files\AspenTech\Apex\Pe\Addin
As of v2004 this file is now a registered component. The first suggestion is to manually register AtProcessDataXLAResources.dll using r... |
Problem Statement: This knowledge base article provides an example of Visual Basic script that shows how to upload XML data to an Aspen Production Record Manager (APRM) server using the APRM Application Programming Interface (API). | Solution: The following is a Visual Basic script that will load one of the xml files (?BDataImportWithAutoConfig.xml?) and call the 'ImportBatchDataXMLForScripting' method to submit it to APRM. This example assumes that the XML file is located in the following directory ?D:\Temp\BDataImportWithAutoConfig.xml?. Also, da... |
Problem Statement: Why is it impossible to UNDO previous commands in Microsoft Excel? | Solution: Here are the reasons that the UNDO capability cannot be implemented:
1. For pure Microsoft Excel, most changes via Macro cannot be Un-done. Execution of those macro also purges actions that were available for undo.
2. Each of the AspenTech MES Excel Add-Ins references dozens of other components includ... |
Problem Statement: Sometimes, when using the Aspen Batch and Event Extractor tool to put batch data into Batch.21 (which means that the characteristics are auto configured before the data is inserted into a batch), the following error is received when using the batch detail display to open one of these batches:
B21BA... | Solution: This happens only when using the Aspen Batch and Event Extractor tool to put batch data into Batch.21. However, the error message 'Specified characteristic is not defined' isn't an Extractor error. It's Batch.21 saying that it doesn't know about the new characteristic. This happens when a characteristic is cr... |
Problem Statement: The following message can be returned from the aspenONE installation when installing on Windows 2003 SP1.
1603: Error installing Windows Installer engine. A file which needs to be replaced may be held in use. Close all applications and try again.
This knowledge base article explains why this message ... | Solution: Windows 2003 SP1 includes a newer version of the Windows installer than the aspenONE media distributes. This error is encountered because the installation of the Windows installer from the aspenONE media fails. The reason the Windows installer fails is because there is already a newer version of the installer... |
Problem Statement: Under certain circumstances it is possible for TSK_DBCLOCK to use up to 50% of the CPU time, which could lead your InfoPlus.21 database to become unresponsive or appear to hang. This could occur if, for example, TSK_DBCLOCK was continually kept busy by the timestamp rescheduling configured by the dat... | Solution: InfoPlus.21 really is not intended to handle such a HUGE number of scheduling timestamp fields, regardless of the reschedule interval. This is perhaps 100x the number at a more typical site. The CPU time required to trigger and reschedule a single scheduling timestamp field is roughly proportional to the tota... |
Problem Statement: This knowledge base article explains why a single value entered into an Aspen InfoPlus.21 database record may seem to be able to trigger more than a single alarm state for the database record. | Solution: The way the deadbanding works with the alarm states is that the data value must actually exceed the alarm limit for the alarm state to change. For example, if the alarm limits were configured in the database record as follows:
IP_HIGH_HIGH_LIMIT = 30
IP_HIGH_LIMIT = 20
IP_LOW_LIMIT = 10
IP_LOW_LOW_LIMIT = 0
a... |
Problem Statement: Aspen MES cluster is a redundancy | Solution: offered by AspenTech. While adding a cluster, you may receive the error:
Failed to open cluster <CLUSTER NAME>.Could not contact the specified cluster.
Followed by the error message:
Retrieving the COM class factory for component with CLSID {F2E~...}failed due to the error:80040154.Solution
AspenTech’s MES re... |
Problem Statement: You may want to load on a production Aspen InfoPlus.21 system some custom records developed on a test Aspen InfoPlus.21 system. Rather than exporting a snapshot, which will overwrite the production database when being loaded there, you would prefer to export a list of specific records.
Is there a sim... | Solution: Yes, this is possible. In the Aspen InfoPlus.21 Administrator right-click on the database object and select Save Records from the context menu. In the GUI, select Find and the Aspen InfoPlus.21 record finder will appear. Query the records you like and drag and drop them to the Save Records window. Then save i... |
Problem Statement: While trying to install AMS software, the user has a logon failure and cannot complete the installation. | Solution: When performing an AMS install, the account being used to install the software must be a member of the local administrator''s group. The reason for this is that the administrators group has particular user rights and policies that allow the appropriate permission for the activities required during an installa... |
Problem Statement: InfoPlus.21 cumulative patch V7.3.0.3 provided a basic application that allowed the user to relocate the InfoPlus.21 folder locations (Defect ID: CQ00461057). IP21ProfileConfiguration could redefine the InfoPlus.21 Data Root folder and some additional child folders by creating the IP21Profiles.xml fi... | Solution: Since V8.0, the new InfoPlus.21 Server System Profiles Manager has completely replaced IP21ProfileConfiguration. It offers much improved functionality as listed below:
An InfoPlus.21 system profile specifies the location of certain InfoPlus.21 folders that hold configuration files: history system files, SQLpl... |
Problem Statement: The following error(s) may be received when attempting to install and application that requires the use of IEWebControls on a Windows Vista client.
Error 1: There was a problem with installing IEWebControls. The error return Code was 1603. Installation cannot proceed
Error 2: The specified path htt... | Solution: The Vista Metabase Compatibility component of IIS 7 must be installed on the server where Aspen Online will be installed. ** This component is not installed by default.**
To install the compatibility component
1. Open the Programs & Features page from the Windows Control Panel
2. Select Turn Win... |
Problem Statement: When I try to update a QueryDef or CompQueryDef record to run at a certain time, the value of SCHEDULE_TIME does not update. | Solution: The #SCHEDULE_TIMES repeat area either in QueryDef or CompQueryDef record is used to store queries that need to run at a regular rate, not for a single instance. To activate this for a single instance, consider adding an activation method in the #WAIT_FOR_COS_FIELDS record, or toggling the value of the EXECUT... |
Problem Statement: This knowledge base article describes why the Aspen Batch.21 web service may not return data when the other Aspen Batch.21 client tools return data when the same batch or time frame is queried. | Solution: Queries executed under the Aspen Batch.21 web service run under the account which is authenticated in IIS. This behavior can occur when the authenticating user for the Aspen Batch.21 web service hasn't been granted permission to the areas from which data is requested. If your site uses anonymous authenticatio... |
Problem Statement: How do I view data in the same time zone as the server, even though the client is in a different time zone? | Solution: TheSolution to this issue is extremely easy in practice, however, the conceptual part can get a little confusing.
Simply put, you will use the Shift column in the legend of Process Explorer to push the data into the correct time . First, make sure the time zone service is configured in ADSA for the datasource... |
Problem Statement: Your MS SQL Server database will continue to use more and more system memory until it eventually takes up all the memory on your NT system. Obviously, this can cause problems with all the other applications running on that node. | Solution: This happens because when SQL Server is installed, it determines the amount of physical memory on the computer, and sets the maximum parameter to that number. Once set, however, this can be changed via the Enterprise Manager. Highlight the server name, right mouse click, select Properties, and go to the tab l... |
Problem Statement: Using the Process Explorer or the Production Record Manager Administration tool you are unable to see or manage the existing Golden Batch Profiles. | Solution: This issue may occur when the amount of profiles has taken or exhausted memory using the Batch21services.exe.
When you open Process Explorer or the Administration tool you may notice that there are no profiles Visible or clicking on a Profile makes the program Non responsive.
If you have BCU , APRM, Batch Ext... |
Problem Statement: How many relational database client licenses are needed to work with Aspen Batch.21 clients? | Solution: The number of licenses for a relational database server (such as SQL Server or Oracle) is irrelevant, since all our requests to the Batch server are performed as impersonated requests by the account that the Aspen Batch.21 Service is running under. Of course the Batch.21 server needs to be on an actual server... |
Problem Statement: How can you share templates created in the Aspen Add-In under the Aspen Process Data menus? | Solution: Templates allow you to save workflow configurations for future use. Once they're created they're saved in a folder under the user’s directory; for example, for user Administrator, the templates he’s created are stored in a XML file, ExcelFormulaTemplates.xml in the folder C:\Users\Administrator\AppData\Ro... |
Problem Statement: How does the Heartbleed OpenSSL bug affect Aspen InfoPlus.21 and related products? | Solution: Heartbleed is a security bug affecting the OpenSSL cryptography library. Most Aspen InfoPlus.21 and related products requiring secure sockets use Microsoft IIS which is not affected by Heartbleed.
The Aspen CIM-IO to OPC-UA interfaces uses the .NET API from the OPC Foundation, which supports the SSL protocol... |
Problem Statement: Users may receive the following error when performing a 'Show | Solution: This is caused by DCOM being locked down. On the Aspen InfoPlus.21 machine click on Start => Run => type DCOMCNFG => click 'OK'.
Expand 'Component Services' => 'Computers' and right-click 'My Computer' => choose 'Properties'.
Switch to the 'COM Security' tab. Beneath 'Access Permissions' click 'Edit Limit... |
Problem Statement: The following error message may be displayed during boot up after installing InfoPlus.21 v3.1: A dialog box appears with the following message: Error 2186 The service is not responding to the control function. In the NT Event Viewer the following error message appears:
The NobleNet Portmapper for TCP... | Solution: The Portmapper is corrupt, which is preventing InfoPlus.21 from starting up. You have to uninstall the Portmapper executable and then reinstall it. Once the portmapper is installed then you can start InfoPlus.21.
Go to: C:\Program Files\Common Files\AspenTech Shared\Portmapper
Select PORTINST.exe, and double ... |
Problem Statement: Existing code is often ported to newer software versions. Sometimes slight enhancements will cause an application to not work with the newer software version. This is such the case when using AspenTech''s 3.x Visual Basic controls to access an InfoPlus.21 v2.5x database. This does not reflect a bug i... | Solution: With the 2.5.x version of InfoPlus.21 and Process Explorer, the hostname or servername is specified in the VB control to direct the program to access data from the proper database. This servername is what gets defined via the Configure Servers dialog box when configuring Process Explorer 2.5.x to view data fr... |
Problem Statement: When invoking the Aspen InfoPlus.21 Health Monitor how can one fix this message which appears after one selects the system name and clicks 'Go':-
Last update time for health task is invalid. Error: String was not recognized as a valid DateTime.
Note: The Aspen InfoPlus.21 Health Monitor was introduce... | Solution: Please do the following:
1. Find TSK_HLTH in the 'Defined Tasks' list in the upper left corner of the Aspen InfoPlus.21 Manager. Double-click on it. This will fill in the task's details on the right side of the screen. Assuming that one wants the Health Monitor to run all the time, uncheck the 'Skip dur... |
Problem Statement: Why might I see multiple instances of my Aspen InfoPlus.21 Database (IP.21 Server) in the scope pane of the Aspen InfoPlus.21 Administrator (IP.21 Administrator) ?
Does my IP.21 Server have a problem ? | Solution: Nothing is wrong with the server.
What you see are multiple data sources providing access to the same database.
Each instance is called by the name of the data source defined in Aspen Data Source Architecture (ADSA).
In the IP.21 Administrator, you can expand any of these data sources to view or modify th... |
Problem Statement: Can I create my own Display Format in Aspen InfoPlus.21? | Solution: Yes, you can create a format that better meets your requirements. On your InfoPlus.21 Administrator you need to go to the building blocks, where you?ll find the Display Formats.
If you want to create a Real Format F5.4, the easiest way is to duplicate the F 5.2 format and call it F 5.4. Then you will need to ... |
Problem Statement: Can a snapshot created using a 32-bit Aspen InfoPlus.21 server be upgraded to a 64-bit server? | Solution: A snapshot created using a 32-bit Aspen InfoPlus.21 server can be upgraded to a 64-bit server provided the version of Aspen InfoPlus.21 is the same version or later.
Keywords: Snapshot
32 bit
64 bit
References: None |
Problem Statement: When Aspen InfoPlus.21 is in a stopped state, how is the value in the SCHEDULE_TIME field of a ScheduledActDef record handled upon startup? | Solution: When stopping and starting IP.21 the SCHEDULE_TIME field is taken into account. For instance if InfoPlus.21 is stopped at 08:30:00.1 and started at 10:15:43.1 for an hourly query scheduled at the top of the hour, the next record activation will be at 11:00:00.0. So it is re-scheduled based upon the ORIGINAL S... |
Problem Statement: Is Aspen InfoPlus.21 (IP.21) multithreaded and will it run on dual processors? | Solution: Yes, InfoPlus.21 can run on a multiprocessor. InfoPlus.21 is a system of multiple processes. That alone means there is some potential benefit in having multiple processors. Some of the InfoPlus.21 processes are multithreaded. So this provides additional advantages.
Having multiple processors can help, but i... |
Problem Statement: Are the records that begin 'D-' used by Aspen InfoPlus.21? | Solution: When browsing the Aspen InfoPlus.21 database using the Aspen InfoPlus.21 Administrator tool one may observe many records that begin withA 'D-', for example D-IP_Analog and D-IP_Discrete. When looking at the contents of these records they don't contain any process data. Is it OK then to delete them or are they... |
Problem Statement: Aspen InfoPlus.21 fails to start at boot, and the following message appears in the output file for TSK_H21_PRIME:
chdir to <C:\Program Files\AspenTech\InfoPlus.21\c21\bin>
Message Code NOT Found: -2506
You may also see the following message in the Windows Application log:
Error during auto start of ... | Solution: After TSK_DBCLOCK completes, the program TSK_H21_PRIME starts a copy of h21archive.exe for each repository. Before starting the archiver programs, TSK_H21_PRIME changes the default directory location to the one containing h21archive.exe. Sometimes, especially in a virtual environment, that folder is not ava... |
Problem Statement: How to determine the rate at which scanned data is stored into Aspen InfoPlus.21 history.
Here is an Aspen SQLPlus script that provides how fast tags are being historized within a repository. The benefit of this script it that it is configurable per repository, number of tags, and the fileset. The re... | Solution: This script is designed to provide the Aspen InfoPlus.21 admin with a list of the point tags in a given repository which use the most disk space.
Note: This script may take several minutes to execute, depending on the size of the specified fileset, because the h21summary procedure executes very slowly with l... |
Problem Statement: After installing IP.21 v3.1 the local IP.21 node is not listed in the IP.21 administrator. | Solution: Remove the data source in the ADSA config tool and re-add it.
Sometimes you also have to reboot the PC.
Keywords: administrator
References: None |
Problem Statement: How do I prevent Aspen IP.21 Administrator from crashing when tryting to create new tag by right clicking on folder? | Solution: On some specific InfoPlus.21 Snapshot it’s observed that when trying to create a new Tag by right clicking on a Folder, IP21 Administrator will get freeze and then crashes.
This issue is due to incorrect value configured in “Folder_links� for that particular folder.
Please follow below steps to upda... |
Problem Statement: Generally an event.dat file is created when the history process, h21archive.exe, is paused or stopped due to file set backups or history system problems. However, there have been cases where an event.dat file is created while the h21archive process is still running. This can happen if data is enterin... | Solution: 1. Check the fragmentation of the hard drive storing the history file sets. Chances are, this drive is badly fragmented, thus creating a performance bottleneck. Data is being collected faster than the history task is able to write to disk. You will need to stop IP.21 and run a defragmentation utility.
2... |
Problem Statement: ghost field를 추가할때 아래와 같이 드롭다운 목록에 내용이 없음. | Solution: 본 이슈는 ghost field로 추가할 field가 이미 custom definition record에 추가되였기 때문입니다.
1) offending field 삭제
2) fixed area에서 아무 field 나 클릭
3) 메뉴 바(menu bar)에서 Fields 클릭
4) New | Ghost Field를 선택하여 New Ghost Field 창을 오픈.
5) Ghost Selector, Ghost Record 와 Ghost Field 를 선택
6) 확인를 클릭하여 Ghost Field 를 custom definition record에 추가
... |
Problem Statement: When launching the Health Monitor from the Aspen InfoPlus.21 Administrator, the IP21 Tasks Health Tests expand to show three fields, but not the field titled IP21 License Tests. | Solution: Navigate to IP21HealthGrpDef and locate IP21TasksHealthTests from that definition record. Make sure the #DATA_BASE_RECORDS field is set to 4 and open the repeat area. Make sure the 4 record names there are: AllIP21TasksRunningTest, IP21TasksReStartingTest, AllIP21ServicesRunTest, and IP21LicenseTests as follo... |
Problem Statement: Can the Aspen InfoPlus.21 OPC-DA server display the contents of folders to an OPC client? | Solution: The Aspen InfoPlus.21 OPC-DA server cannot display the contents of folders to OPC clients even though you can add folder records to the record IP_TagsBranch.
Keywords: Aspen InfoPlus.21 DA OPC server, Aspen.InfoPlus21_DA.1, PE_BranchDef, IP_TagsBranch, FolderDef, Folder
References: None |
Problem Statement: Snapshot Upgrade Wizard fails to upgrade a snapshot with the following error message when trying to upgrade to an existing target snapshot file:
ERROR in saving output snapshot, code=-11, name=InfoPlus.21.snp, length=14 | Solution: The above error message sometimes occurs when the user doesn't have a permission to overwrite the target snapshot file or it cannot be overwritten for some other reason such as being locked by another process or application.
PossibleSolutions:
Run the Snapshot Upgrade Wizard again and give the target snapshot... |
Problem Statement: Sometimes when upgrading the Aspen InfoPlus.21 database snapshot from older versions to V7.3, upgrade fails with the error error in creating new long names segment, code=-9 | Solution: In order to resolve this error the Free Space should be increased on the source snapshot by loading it on the older IP.21 version you are upgrading from. Use the following procedure in order to increase the Free Space :
1. Log in to the Aspen InfoPlus.21 (IP.21) server machine (older version you are upgrading... |
Problem Statement: The external task used for Aspen KPI is called TSK_KPI. As with all external tasks there is an Error file associated with the task called TSK_KPI.ERR
Sometimes an error (or warning) message is generated with a number, such as
Failed in .\KPITask.cpp , line 151, record Unknown, error number -37.
Where... | Solution: Look in ...\Infoplus.21\db21\include folder for file setcim.h. This is a header file that defines numerous system variables that are used within the Aspen InfoPlus.21 system.
Open setcim.h in Notepad and then search for the error code that was returned when a problem was encountered.
An example would be:
06... |
Problem Statement: We have had a few cases where, for some data records only, the users cannot see any History Repeat Area fields via the Administrator tool, nor via Process Explorer, but they can with some other tools such as SQLplus. This would typically only be seen with records defined by a Custom Definition record... | Solution: TwoSolutions:
1. Delete all data records defined by the Custom Definition Record, Make the Definition record Unusable, and modify it to explicitly contain a Key Timestamp field. Finally, make the Definition record Usable and re-create the data records. Warning, this will cause you to lose all of your ol... |
Problem Statement: What causes the error h21 shared-memory size is too big in TSK_DBCLOCK.ERR when trying to start Aspen InfoPlus.21? | Solution: This error indicates a problem in the file config.dat. TSK_DBCLOCK reads the contents of config.dat and allocates the memory required by the historian. Look at KB 124960 entitled What are the command line parameters for TSK_DBCLOCK and what does TSK_DBCLOCK do when starting Aspen InfoPlus.21?.
To work arou... |
Problem Statement: The Data Source Configuration Tool will not offer MS Access as a database option if MS SQL was previously selected or the registry keys for a previously installed Aspen Framework version are present. This document describes a workaround to this problem which will be fixed in the next release. | Solution: Three parameters in the AFW Registry folder should be deleted.
1. Using the Regedit utility, expose the AFW folder by expanding HKEY_LOCAL_MACHINE\SOFTWARE\AspenTech and selecting AFW.
2. After selecting the PROVIDER, DATABASE and DATASOURCE parameters in the right pane, choose the delete right cl... |
Problem Statement: After installing InfoPlus.21, the machine must be rebooted. During the the reboot, the following messages may be displayed:
Couldn''t create service ''AtLocalAFWTrusteeServer''. Error Code= 0x80070241.
Couldn''t create service ''AtRegistrySecurityServer''. Error Code= 0x80070241. | Solution: The installation must be performed using a Domain\User account. When prompted for information in the Windows NT Service Configuration dialog box, a Domain\Username is required.
Even when an account on the local machine is used for the installation, a Domain is required. In this case, the Domain would be the l... |
Problem Statement: During the installation of the AMS 4.0 or 4.1 CD, generally during an upgrade from earlier versions, there have been cases of the following error at step 1 or 2:
the installation of core component Aspen License Manager fails. Set up cannot continue. | Solution: Open the registry by going to Start | Run | Regedt32.
Go to the registry key:
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders\
The keys under User Shell Folders should have the data type of REG_EXPAND_SZ. If not already set, set the values to:
Common Admin Tools - %ALL... |
Problem Statement: How can I change the database name displayed in the Aspen InfoPlus.21 Administrator? | Solution: The database name displayed in the Aspen InfoPlus.21 Administrator is taken from the Aspen Data Source configuration tool. In other words, you can just edit the data source name of your Aspen InfoPlus.21 using the ADSA Client Config Tool and refresh the Aspen InfoPlus.21 Administrator window to see the new na... |