Stereo + IMU Egocentric Capture
Technical Evaluation · Field Note #03
ORIGIN DATA LAB · Real-World Data Production for Physical AI
Short answer. In a 120 s head-mounted stereo + IMU recording, all 3,600 / 3,600 stereo pairs shared the device frame tick, the device-recorded left/right exposure-centre offset had a median of 20.5 µs, and the IMU delivered ≈501.7 Hz with no gaps on the same clock as the video. Under auto-exposure, using the frame tick instead of the exposure centre biases frame time by about 5 ms.
Publication scope: technical evaluation, measurement figures and documentation only. The underlying raw stereo videos and IMU time series are not distributed here, and this is not a production calibration certificate or a robot-learning benchmark.
At a glance
| Evaluated recording | Stereo streams | IMU | Frame coverage |
|---|---|---|---|
| 120 seconds | 2 × 1600 × 1200 @ 30 fps | 6-axis · ~501.7 Hz | 3,600 frames per camera |
A head-mounted stereo egocentric recording of an indoor two-handed workbench assembly task was evaluated for frame correspondence, timing, sensor continuity, image quality and calibration evidence. Measurements and limitations are presented separately to avoid conflating recorded evidence, estimates and unverified claims.
Evaluation summary
| Metric / claim | Observation | Evidence status |
|---|---|---|
| Stereo frame tick correspondence | 3,600 / 3,600 matched pairs | Verified in evaluated record |
| Frame counter continuity | No missing increments observed | Verified in evaluated record |
| Visual motion alignment | Peak at zero-frame lag; r = 0.997 | Evaluated |
| Left/right exposure-center difference | Median 20.5 µs; mean 21.1 ± 2.9 µs | Device-reported; not independently verified |
| IMU sample rate | Approximately 501.7 Hz | Verified in evaluated record |
| IMU continuity | No observed gaps, duplicates or saturation in tested range | Verified in evaluated record |
| Camera–IMU timing offsets | Left −1.1 ms; right −1.2 ms | Estimate — consistent within a few ms only |
| Stereo calibration for evaluated capture mode | Mode-matched Kalibr calibration: median angular epipolar error 0.41 px | Verified (update, see Field Note #04) |
| Camera–IMU extrinsics | Kalibr values exist; not verifiable from this recording | Calibrated, not independently verified |
| Robot-learning performance | Not tested | Not assessed |
Update, 23 October 2026. A Kalibr calibration produced in the same 1600 × 1200 mode was validated on this recording without adjustment (Field Note #04 · dataset card). The same target-free video–gyro method, applied to a recording with a Kalibr camera–IMU reference, missed the reference time shift by several milliseconds — so the −1.1 / −1.2 ms figures indicate alignment within a few milliseconds, not a measured offset.
Visual evidence gallery
01 · Stereo imagery and exposure timing
Representative stereo image pair from the evaluated recording. Monitor screens are blurred for public release.
Timing analysis based on recorded camera metadata. Exposure-center differences are device-reported rather than externally certified.
02 · IMU signal quality and sampling
Inertial signals and sampling interval diagnostics for the evaluated segment.
03 · Visual–inertial temporal relationship
Visual motion and gyroscope comparison. Camera–IMU offsets are diagnostic estimates, not certified hardware synchronization.
04 · Stereo rectification with the originally supplied (mode-mismatched) file
These residuals come from a calibration file produced in a different (16:9) mode. A mode-matched calibration has since been validated at 0.41 px (Field Note #04).
05 · Frame-level image quality
Image-quality variation across the evaluated recording.
What is verified — and what is not
Supported by the evaluated record: video decoding, frame continuity, recorded stereo tick pairing, IMU continuity, diagnostic motion comparison and (since 23 Oct 2026) mode-matched stereo calibration fit.
Requires additional validation: independent optical stereo timing confirmation, metric depth accuracy, and independent camera–IMU extrinsic and time-offset verification. No downstream VLA/robot policy training performance is claimed.
See VALIDATION_STATUS.md for the full evidence matrix and TECHNICAL_REPORT.md for methods, interpretation and limitations.
Repository contents
| Path | Description |
|---|---|
README.md |
Dataset card, measurement summary and evidence gallery |
TECHNICAL_REPORT.md |
Technical evaluation methodology and findings |
VALIDATION_STATUS.md |
Claim-by-claim validation boundaries |
figures/*.webp |
Nine diagnostic figures from the published evaluation |
Not included: source MP4 recordings, raw IMU logs, full per-frame sensor metadata, calibration parameters, training-ready annotations or dataset splits. The Dataset Viewer may not show sample rows because this is a documentation-only technical evidence release.
Cite
@misc{origindatalab2026fieldnote03,
author = {{Origin Data Lab}},
title = {Stereo + IMU Egocentric Capture: Measured Synchronization, Timing Model and Calibration Findings},
howpublished = {Technical Field Note \#03},
year = {2026},
url = {https://origindatalab.io/technical-field-notes/stereo-imu-egocentric-sample.html}
}
Custom data production and evaluation pilots
Origin Data Lab supports scoped real-world data collection for robotics and Physical AI, including egocentric/stereo video, inertial metadata, field operations, quality review and engineering-oriented deliverables. Production specifications and acceptance criteria are agreed per project.
Request a technical evaluation or paid pilot · contact@origindatalab.io
Origin Data Lab · October 2026 · Text and figures: CC BY-NC 4.0 — attribution to Origin Data Lab.