new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 4

Vision Tomography: Towards Portable 3D Bidirectional Face-Skull Inference from Visual Data

Traditional computed tomography (CT) can capture paired 3D face and skull geometry, but it remains costly, fixed in location, and exposes patients to radiation. For applications such as remote diagnostics, digital healthcare, forensic identification, missing-person investigation, and archaeological analysis, there is an urgent need for a portable, safe, and accessible solution to capture 3D skull geometry. In this work, we introduce Vision Tomography (VT), a concept and framework capable of reconstructing paired 3D face-skull geometry from various visual modalities, and also enabling joint manipulation of 3D facial and skull geometry. To achieve this, we first construct a dataset of over 200 samples, where each case includes a CT-based skull, a CT-based face, and a high-fidelity textured face scan. Secondly, we propose a novel dense ray matching registration method that ensures topological consistency across face, skull, and their tissue correspondences. Building on this registration, we introduce the 3D Bidirectional Face-Skull Morphable Model (BFSM) as the foundation of Vision Tomography, which enables shape inference between the face and skull through a shared coefficient space, while also modeling tissue thickness variation to support one-to-many facial reconstructions from the same skull, reflecting individual facial changes such as age or body fat. Finally, we demonstrate the effectiveness of Vision Tomography across various forensic and medical applications, including paired 3D face-skull reconstruction from images or sketches and predicting surgical outcomes with joint face-skull editing. Extensive experiments confirm the robustness and accuracy of our method. Vision Tomography is available at https://github.com/wang-zidu/BFSM

  • 8 authors
·
Oct 26

PET2Rep: Towards Vision-Language Model-Drived Automated Radiology Report Generation for Positron Emission Tomography

Positron emission tomography (PET) is a cornerstone of modern oncologic and neurologic imaging, distinguished by its unique ability to illuminate dynamic metabolic processes that transcend the anatomical focus of traditional imaging technologies. Radiology reports are essential for clinical decision making, yet their manual creation is labor-intensive and time-consuming. Recent advancements of vision-language models (VLMs) have shown strong potential in medical applications, presenting a promising avenue for automating report generation. However, existing applications of VLMs in the medical domain have predominantly focused on structural imaging modalities, while the unique characteristics of molecular PET imaging have largely been overlooked. To bridge the gap, we introduce PET2Rep, a large-scale comprehensive benchmark for evaluation of general and medical VLMs for radiology report generation for PET images. PET2Rep stands out as the first dedicated dataset for PET report generation with metabolic information, uniquely capturing whole-body image-report pairs that cover dozens of organs to fill the critical gap in existing benchmarks and mirror real-world clinical comprehensiveness. In addition to widely recognized natural language generation metrics, we introduce a series of clinical efficiency metrics to evaluate the quality of radiotracer uptake pattern description in key organs in generated reports. We conduct a head-to-head comparison of 30 cutting-edge general-purpose and medical-specialized VLMs. The results show that the current state-of-the-art VLMs perform poorly on PET report generation task, falling considerably short of fulfilling practical needs. Moreover, we identify several key insufficiency that need to be addressed to advance the development in medical applications.

  • 15 authors
·
Aug 5, 2025

Merlin: A Vision Language Foundation Model for 3D Computed Tomography

Over 85 million computed tomography (CT) scans are performed annually in the US, of which approximately one quarter focus on the abdomen. Given the current radiologist shortage, there is a large impetus to use artificial intelligence to alleviate the burden of interpreting these complex imaging studies. Prior state-of-the-art approaches for automated medical image interpretation leverage vision language models (VLMs). However, current medical VLMs are generally limited to 2D images and short reports, and do not leverage electronic health record (EHR) data for supervision. We introduce Merlin - a 3D VLM that we train using paired CT scans (6+ million images from 15,331 CTs), EHR diagnosis codes (1.8+ million codes), and radiology reports (6+ million tokens). We evaluate Merlin on 6 task types and 752 individual tasks. The non-adapted (off-the-shelf) tasks include zero-shot findings classification (31 findings), phenotype classification (692 phenotypes), and zero-shot cross-modal retrieval (image to findings and image to impressions), while model adapted tasks include 5-year disease prediction (6 diseases), radiology report generation, and 3D semantic segmentation (20 organs). We perform internal validation on a test set of 5,137 CTs, and external validation on 7,000 clinical CTs and on two public CT datasets (VerSe, TotalSegmentator). Beyond these clinically-relevant evaluations, we assess the efficacy of various network architectures and training strategies to depict that Merlin has favorable performance to existing task-specific baselines. We derive data scaling laws to empirically assess training data needs for requisite downstream task performance. Furthermore, unlike conventional VLMs that require hundreds of GPUs for training, we perform all training on a single GPU.

  • 31 authors
·
Jun 10, 2024

Vision-Language Models for Automated 3D PET/CT Report Generation

Positron emission tomography/computed tomography (PET/CT) is essential in oncology, yet the rapid expansion of scanners has outpaced the availability of trained specialists, making automated PET/CT report generation (PETRG) increasingly important for reducing clinical workload. Compared with structural imaging (e.g., X-ray, CT, and MRI), functional PET poses distinct challenges: metabolic patterns vary with tracer physiology, and whole-body 3D contextual information is required rather than local-region interpretation. To advance PETRG, we propose PETRG-3D, an end-to-end 3D dual-branch framework that separately encodes PET and CT volumes and incorporates style-adaptive prompts to mitigate inter-hospital variability in reporting practices. We construct PETRG-Lym, a multi-center lymphoma dataset collected from four hospitals (824 reports w/ 245,509 paired PET/CT slices), and construct AutoPET-RG-Lym, a publicly accessible PETRG benchmark derived from open imaging data but equipped with new expert-written, clinically validated reports (135 cases). To assess clinical utility, we introduce PETRG-Score, a lymphoma-specific evaluation protocol that jointly measures metabolic and structural findings across curated anatomical regions. Experiments show that PETRG-3D substantially outperforms existing methods on both natural language metrics (e.g., +31.49\% ROUGE-L) and clinical efficacy metrics (e.g., +8.18\% PET-All), highlighting the benefits of volumetric dual-modality modeling and style-aware prompting. Overall, this work establishes a foundation for future PET/CT-specific models emphasizing disease-aware reasoning and clinically reliable evaluation. Codes, models, and AutoPET-RG-Lym will be released.

  • 11 authors
·
Nov 24, 2025

RetFiner: A Vision-Language Refinement Scheme for Retinal Foundation Models

The rise of imaging techniques such as optical coherence tomography (OCT) and advances in deep learning (DL) have enabled clinicians and researchers to streamline retinal disease staging. A popular DL approach is self-supervised learning (SSL), where models learn from vast amounts of unlabeled data, avoiding costly annotation. SSL has allowed the development of foundation models (FMs), large models that can be used for a variety of downstream tasks. However, existing FMs for OCT, trained solely on image data, lack a comprehensive and robust semantic understanding of images, as evidenced by their downstream performance (especially for complex tasks), and thus require supervised fine-tuning (which may be unfeasible) to better adapt to specific applications and populations. To address this, we propose RetFiner, an SSL vision-language refinement scheme that improves the representations of existing FMs and enables their efficient and direct adaptation to specific populations for improved downstream performance. Our method uses a diverse set of training objectives which take advantage of the rich supervisory signal found in textual data. We tested RetFiner on the retinal FMs RETFound, UrFound, and VisionFM, showing significant improvements in linear probing performance on seven highly diverse OCT classification tasks, with an average increase of 5.8, 3.9, and 2.1 percentage points over their baselines, respectively. Our code and model weights are publicly available at https://github.com/ronnief1/RetFiner.

  • 4 authors
·
Jun 27, 2025 1

SpinalSAM-R1: A Vision-Language Multimodal Interactive System for Spine CT Segmentation

The anatomical structure segmentation of the spine and adjacent structures from computed tomography (CT) images is a key step for spinal disease diagnosis and treatment. However, the segmentation of CT images is impeded by low contrast and complex vertebral boundaries. Although advanced models such as the Segment Anything Model (SAM) have shown promise in various segmentation tasks, their performance in spinal CT imaging is limited by high annotation requirements and poor domain adaptability. To address these limitations, we propose SpinalSAM-R1, a multimodal vision-language interactive system that integrates a fine-tuned SAM with DeepSeek-R1, for spine CT image segmentation. Specifically, our SpinalSAM-R1 introduces an anatomy-guided attention mechanism to improve spine segmentation performance, and a semantics-driven interaction protocol powered by DeepSeek-R1, enabling natural language-guided refinement. The SpinalSAM-R1 is fine-tuned using Low-Rank Adaptation (LoRA) for efficient adaptation. We validate our SpinalSAM-R1 on the spine anatomical structure with CT images. Experimental results suggest that our method achieves superior segmentation performance. Meanwhile, we develop a PyQt5-based interactive software, which supports point, box, and text-based prompts. The system supports 11 clinical operations with 94.3\% parsing accuracy and sub-800 ms response times. The software is released on https://github.com/6jm233333/spinalsam-r1.

  • 6 authors
·
Oct 30, 2025

PETAR: Localized Findings Generation with Mask-Aware Vision-Language Modeling for PET Automated Reporting

Generating automated reports for 3D positron emission tomography (PET) is an important and challenging task in medical imaging. PET plays a vital role in oncology, but automating report generation is difficult due to the complexity of whole-body 3D volumes, the wide range of potential clinical findings, and the limited availability of annotated datasets. To address these challenges, we introduce PETARSeg-11K, the first large-scale, publicly available dataset that provides lesion-level correspondence between 3D PET/CT volumes and free-text radiological findings. It comprises 11,356 lesion descriptions paired with 3D segmentations. Second, we propose PETAR-4B, a 3D vision-language model designed for mask-aware, spatially grounded PET/CT reporting. PETAR-4B jointly encodes PET, CT, and 3D lesion segmentation masks, using a 3D focal prompt to capture fine-grained details of lesions that normally comprise less than 0.1% of the volume. Evaluations using automated metrics show PETAR-4B substantially outperforming all 2D and 3D baselines. A human study involving five physicians -- the first of its kind for automated PET reporting -- confirms the model's clinical utility and establishes correlations between automated metrics and expert judgment. This work provides a foundational dataset and a novel architecture, advancing 3D medical vision-language understanding in PET.

  • 14 authors
·
Nov 29, 2025

Learning Robust Visual Features in Computed Tomography Enables Efficient Transfer Learning for Clinical Tasks

There is substantial interest in developing artificial intelligence systems to support radiologists across tasks ranging from segmentation to report generation. Existing computed tomography (CT) foundation models have largely focused on building generalist vision-language systems capable of tasks such as question answering and report generation. However, training reliable vision-language systems requires paired image-text data at a scale that remains unavailable in CT. Moreover, adapting the underlying visual representations to downstream tasks typically requires partial or full backbone fine-tuning, a computationally demanding process inaccessible to many research groups. Instead, foundation models should prioritise learning robust visual representations that enable efficient transfer to new tasks with minimal labelled data and without backbone fine-tuning. We present VoxelFM, a 3D CT foundation model trained with self-distillation using the DINO framework, which learns semantically rich features without language supervision. We evaluated VoxelFM across seven categories of clinically relevant downstream tasks using frozen backbone representations with lightweight probes: classification, regression, survival analysis, instance retrieval, localisation, segmentation, and report generation. VoxelFM matched or outperformed four existing CT foundation models across all task categories. Despite receiving no language supervision during pre-training, VoxelFM surpassed models explicitly trained with language-alignment objectives, including on report generation. Our results indicate that current CT foundation models perform significantly better as feature extractors for lightweight probes rather than as vision encoders for vision-language models. Model weights and training code are publicly available.

  • 5 authors
·
Apr 4

Text-to-CT Generation via 3D Latent Diffusion Model with Contrastive Vision-Language Pretraining

Objective: While recent advances in text-conditioned generative models have enabled the synthesis of realistic medical images, progress has been largely confined to 2D modalities such as chest X-rays. Extending text-to-image generation to volumetric Computed Tomography (CT) remains a significant challenge, due to its high dimensionality, anatomical complexity, and the absence of robust frameworks that align vision-language data in 3D medical imaging. Methods: We introduce a novel architecture for Text-to-CT generation that combines a latent diffusion model with a 3D contrastive vision-language pretraining scheme. Our approach leverages a dual-encoder CLIP-style model trained on paired CT volumes and radiology reports to establish a shared embedding space, which serves as the conditioning input for generation. CT volumes are compressed into a low-dimensional latent space via a pretrained volumetric VAE, enabling efficient 3D denoising diffusion without requiring external super-resolution stages. Results: We evaluate our method on the CT-RATE dataset and conduct a comprehensive assessment of image fidelity, clinical relevance, and semantic alignment. Our model achieves competitive performance across all tasks, significantly outperforming prior baselines for text-to-CT generation. Moreover, we demonstrate that CT scans synthesized by our framework can effectively augment real data, improving downstream diagnostic performance. Conclusion: Our results show that modality-specific vision-language alignment is a key component for high-quality 3D medical image generation. By integrating contrastive pretraining and volumetric diffusion, our method offers a scalable and controllable solution for synthesizing clinically meaningful CT volumes from text, paving the way for new applications in data augmentation, medical education, and automated clinical simulation.

  • 5 authors
·
May 31, 2025

GLINT: Sparsely Gated Vision-Language Alignment for Fine-Grained Radiology Representations

Vision-language models (VLMs) for radiology have emerged as a scalable paradigm by leveraging image-report pairs naturally produced in clinical workflows. However, this pairing reveals a mismatch in scale: each finding occupies only a small region of the image, yet supervision is provided only at the global image-report level. This poses a central challenge: prior approaches spread weight densely across all patches rather than concentrating on the sparse subset relevant to a given query. To address this, we present GLINT (Gated Language-Image alignmeNT), a framework that explicitly models this sparse correspondence. On the alignment side, we introduce Sparsely Gated Alignment, a novel architecture in which a sigmoid gate over a separate gate embedding space activates only the patches relevant to each textual query, enforcing explicit sparsity. On the representation side, we add Dense Feature Regularization, which anchors the trainable encoder's intermediate features to a frozen self-supervised learning (SSL) teacher, preserving the fine-grained patch features that the gate relies on. The same recipe applies to both 2D chest X-ray (CXR) and 3D chest computed tomography (CT), built with DINOv3 and V-JEPA 2.1, respectively. GLINT enables zero-shot classification, grounding, and segmentation from free-text queries, and to our knowledge is the first to demonstrate zero-shot segmentation on 3D CT volumes without mask supervision. Notably, the most pronounced gains arise on zero-shot grounding and segmentation, where sparse, query-specific localization is required, consistent with our design intent. In downstream evaluation, GLINT outperforms both SSL encoders and medical VLMs on classification, report generation, and segmentation.

  • 9 authors
·
Jun 1

Better Tokens for Better 3D: Advancing Vision-Language Modeling in 3D Medical Imaging

Recent progress in vision-language modeling for 3D medical imaging has been fueled by large-scale computed tomography (CT) corpora with paired free-text reports, stronger architectures, and powerful pretrained models. This has enabled applications such as automated report generation and text-conditioned 3D image synthesis. Yet, current approaches struggle with high-resolution, long-sequence volumes: contrastive pretraining often yields vision encoders that are misaligned with clinical language, and slice-wise tokenization blurs fine anatomy, reducing diagnostic performance on downstream tasks. We introduce BTB3D (Better Tokens for Better 3D), a causal convolutional encoder-decoder that unifies 2D and 3D training and inference while producing compact, frequency-aware volumetric tokens. A three-stage training curriculum enables (i) local reconstruction, (ii) overlapping-window tiling, and (iii) long-context decoder refinement, during which the model learns from short slice excerpts yet generalizes to scans exceeding 300 slices without additional memory overhead. BTB3D sets a new state-of-the-art on two key tasks: it improves BLEU scores and increases clinical F1 by 40% over CT2Rep, CT-CHAT, and Merlin for report generation; and it reduces FID by 75% and halves FVD compared to GenerateCT and MedSyn for text-to-CT synthesis, producing anatomically consistent 512*512*241 volumes. These results confirm that precise three-dimensional tokenization, rather than larger language backbones alone, is essential for scalable vision-language modeling in 3D medical imaging. The codebase is available at: https://github.com/ibrahimethemhamamci/BTB3D

  • 10 authors
·
Oct 23, 2025

KorMedMCQA-V: A Multimodal Benchmark for Evaluating Vision-Language Models on the Korean Medical Licensing Examination

We introduce KorMedMCQA-V, a Korean medical licensing-exam-style multimodal multiple-choice question answering benchmark for evaluating vision-language models (VLMs). The dataset consists of 1,534 questions with 2,043 associated images from Korean Medical Licensing Examinations (2012-2023), with about 30% containing multiple images requiring cross-image evidence integration. Images cover clinical modalities including X-ray, computed tomography (CT), electrocardiography (ECG), ultrasound, endoscopy, and other medical visuals. We benchmark over 50 VLMs across proprietary and open-source categories-spanning general-purpose, medical-specialized, and Korean-specialized families-under a unified zero-shot evaluation protocol. The best proprietary model (Gemini-3.0-Pro) achieves 96.9% accuracy, the best open-source model (Qwen3-VL-32B-Thinking) 83.7%, and the best Korean-specialized model (VARCO-VISION-2.0-14B) only 43.2%. We further find that reasoning-oriented model variants gain up to +20 percentage points over instruction-tuned counterparts, medical domain specialization yields inconsistent gains over strong general-purpose baselines, all models degrade on multi-image questions, and performance varies notably across imaging modalities. By complementing the text-only KorMedMCQA benchmark, KorMedMCQA-V forms a unified evaluation suite for Korean medical reasoning across text-only and multimodal conditions. The dataset is available via Hugging Face Datasets: https://huggingface.co/datasets/seongsubae/KorMedMCQA-V.

  • 4 authors
·
Feb 14

MedTri: A Platform for Structured Medical Report Normalization to Enhance Vision-Language Pretraining

Medical vision-language pretraining increasingly relies on medical reports as large-scale supervisory signals; however, raw reports often exhibit substantial stylistic heterogeneity, variable length, and a considerable amount of image-irrelevant content. Although text normalization is frequently adopted as a preprocessing step in prior work, its design principles and empirical impact on vision-language pretraining remain insufficiently and systematically examined. In this study, we present MedTri, a deployable normalization framework for medical vision-language pretraining that converts free-text reports into a unified [Anatomical Entity: Radiologic Description + Diagnosis Category] triplet. This structured, anatomy-grounded normalization preserves essential morphological and spatial information while removing stylistic noise and image-irrelevant content, providing consistent and image-grounded textual supervision at scale. Across multiple datasets spanning both X-ray and computed tomography (CT) modalities, we demonstrate that structured, anatomy-grounded text normalization is an important factor in medical vision-language pretraining quality, yielding consistent improvements over raw reports and existing normalization baselines. In addition, we illustrate how this normalization can easily support modular text-level augmentation strategies, including knowledge enrichment and anatomy-grounded counterfactual supervision, which provide complementary gains in robustness and generalization without altering the core normalization process. Together, our results position structured text normalization as a critical and generalizable preprocessing component for medical vision-language learning, while MedTri provides this normalization platform. Code and data will be released at https://github.com/Arturia-Pendragon-Iris/MedTri.

  • 5 authors
·
Feb 25

Triad: Vision Foundation Model for 3D Magnetic Resonance Imaging

Vision foundation models (VFMs) are pre-trained on extensive image datasets to learn general representations for diverse types of data. These models can subsequently be fine-tuned for specific downstream tasks, significantly boosting performance across a broad range of applications. However, existing vision foundation models that claim to be applicable to various clinical tasks are mostly pre-trained on 3D computed tomography (CT), which benefits from the availability of extensive 3D CT databases. Significant differences between CT and magnetic resonance imaging (MRI) in imaging principles, signal characteristics, and data distribution may hinder their practical performance and versatility in MRI-specific applications. Here, we propose Triad, a vision foundation model for 3D MRI. Triad adopts a widely used autoencoder architecture to learn robust representations from 131,170 3D MRI volumes and uses organ-independent imaging descriptions to constrain the semantic distribution of the visual modality. The above pre-training dataset is called Triad-131K, which is currently the largest 3D MRI pre-training dataset. We evaluate Triad across three tasks, namely, organ/tumor segmentation, organ/cancer classification, and medical image registration, in two data modalities (within-domain and out-of-domain) settings using 25 downstream datasets. By initializing models with Triad's pre-trained weights, nnUNet-Triad improves segmentation performance by 2.51% compared to nnUNet-Scratch across 17 datasets. Swin-B-Triad achieves a 3.97% improvement over Swin-B-Scratch in classification tasks across five datasets. SwinUNETR-Triad improves by 4.00% compared to SwinUNETR-Scratch in registration tasks across two datasets. Our study demonstrates that pre-training can improve performance when the data modalities and organs of upstream and downstream tasks are consistent.

  • 8 authors
·
Feb 22, 2025

A Unified Framework for Comprehensive Cardiac CT Segmentation and Phenotyping: Human-in-the-Loop Data Annotation, Vision Foundation Model Development, Multicenter Evaluation and Clinical Validation

Comprehensive quantification of cardiac structures from computed tomography (CT) remains limited not by data availability but by the scalability of measurements, which makes routine use impractical. Here we present a unified framework for comprehensive cardiac CT segmentation and phenotyping that combines a human-in-the-loop annotation pipeline, a cardiac CT augmentation technique, and a self-supervised foundation model pre-trained on 60,000 unlabeled cardiac CT scans. Using this approach, we assembled the largest and most comprehensive expert-annotated cardiac CT segmentation dataset to date, comprising 1598 cases and 14 distinct cardiac structures (1000 for training, 598 for the external test set). Across five external datasets, the framework segmented all structures more accurately and comprehensively than existing open-source tools. Self-supervised pre-training improved labeling efficiency, with the most significant gains observed during external evaluation in the low-data regime. Benchmarking across convolutional, transformer, and state-space architectures showed comparable performance, indicating that data quality and pre-training, rather than architecture, drove accuracy. The framework was scaled to population-level phenotyping, with segmented anatomy that carries functionally relevant information about ventricular function and disease severity beyond demographic variables. By openly releasing the largest dataset with human labels, code, model weights, a CT augmentation library, and software, this work provides a reproducible foundation for opportunistic cardiac phenotyping from routinely acquired CT scans.

  • 20 authors
·
Jul 12

Does DINOv3 Set a New Medical Vision Standard?

The advent of large-scale vision foundation models, pre-trained on diverse natural images, has marked a paradigm shift in computer vision. However, how the frontier vision foundation models' efficacies transfer to specialized domains remains such as medical imaging remains an open question. This report investigates whether DINOv3, a state-of-the-art self-supervised vision transformer (ViT) that features strong capability in dense prediction tasks, can directly serve as a powerful, unified encoder for medical vision tasks without domain-specific pre-training. To answer this, we benchmark DINOv3 across common medical vision tasks, including 2D/3D classification and segmentation on a wide range of medical imaging modalities. We systematically analyze its scalability by varying model sizes and input image resolutions. Our findings reveal that DINOv3 shows impressive performance and establishes a formidable new baseline. Remarkably, it can even outperform medical-specific foundation models like BiomedCLIP and CT-Net on several tasks, despite being trained solely on natural images. However, we identify clear limitations: The model's features degrade in scenarios requiring deep domain specialization, such as in Whole-Slide Pathological Images (WSIs), Electron Microscopy (EM), and Positron Emission Tomography (PET). Furthermore, we observe that DINOv3 does not consistently obey scaling law in the medical domain; performance does not reliably increase with larger models or finer feature resolutions, showing diverse scaling behaviors across tasks. Ultimately, our work establishes DINOv3 as a strong baseline, whose powerful visual features can serve as a robust prior for multiple complex medical tasks. This opens promising future directions, such as leveraging its features to enforce multiview consistency in 3D reconstruction.

  • 19 authors
·
Sep 8, 2025 3

CT-$Δ$Bench: A Benchmark for Longitudinal 3D Medical Imaging Difference Reporting with Vision-Language Models

In medical imaging, the clinical value of Computed Tomography (CT) lies not only in depicting current disease status, but crucially in enabling longitudinal comparison of serial scans to determine disease evolution, a process that underpins response assessment, recurrence detection, and ongoing patient management. Yet, despite this central role of temporal comparison in clinical decision-making, existing medical foundation models remain largely confined to single-study understanding, leaving temporally grounded cross-examination insufficiently addressed. To address this gap, we study longitudinal imaging difference reporting, a task in which a model takes two temporally separated scans from the same patient and generates a clinically meaningful report describing interval changes between them. We introduce CT-ΔBench, a dedicated benchmark for this task with patient-level splitting to prevent information leakage. To better evaluate this task beyond surface-level text similarity, we further develop change-aware metrics specifically designed to capture clinically meaningful longitudinal changes, and conduct an independent physician validation to assess the reliability of the synthesized references and event extraction pipeline. We also compare direct paired-CT reasoning with an indirect two-stage pipeline that first generates single-timepoint reports and then performs textual differencing. Finally, we propose DeltaMed, a baseline model for direct paired-CT difference reporting, and train it on the benchmark training set. Together, these contributions lay the groundwork for temporally aware medical foundation models that better reflect real-world longitudinal clinical reasoning.

  • 4 authors
·
Aug 11

Med-R1: Reinforcement Learning for Generalizable Medical Reasoning in Vision-Language Models

Vision-language models (VLMs) have advanced reasoning in natural scenes, but their role in medical imaging remains underexplored. Medical reasoning tasks demand robust image analysis and well-justified answers, posing challenges due to the complexity of medical images. Transparency and trustworthiness are essential for clinical adoption and regulatory compliance. We introduce Med-R1, a framework exploring reinforcement learning (RL) to enhance VLMs' generalizability and trustworthiness in medical reasoning. Leveraging the DeepSeek strategy, we employ Group Relative Policy Optimization (GRPO) to guide reasoning paths via reward signals. Unlike supervised fine-tuning (SFT), which often overfits and lacks generalization, RL fosters robust and diverse reasoning. Med-R1 is evaluated across eight medical imaging modalities: CT, MRI, Ultrasound, Dermoscopy, Fundus Photography, Optical Coherence Tomography (OCT), Microscopy, and X-ray Imaging. Compared to its base model, Qwen2-VL-2B, Med-R1 achieves a 29.94% accuracy improvement and outperforms Qwen2-VL-72B, which has 36 times more parameters. Testing across five question types-modality recognition, anatomy identification, disease diagnosis, lesion grading, and biological attribute analysis Med-R1 demonstrates superior generalization, exceeding Qwen2-VL-2B by 32.06% and surpassing Qwen2-VL-72B in question-type generalization. These findings show that RL improves medical reasoning and enables parameter-efficient models to outperform significantly larger ones. With interpretable reasoning outputs, Med-R1 represents a promising step toward generalizable, trustworthy, and clinically viable medical VLMs.

  • 5 authors
·
Mar 18, 2025

LMOD: A Large Multimodal Ophthalmology Dataset and Benchmark for Large Vision-Language Models

The prevalence of vision-threatening eye diseases is a significant global burden, with many cases remaining undiagnosed or diagnosed too late for effective treatment. Large vision-language models (LVLMs) have the potential to assist in understanding anatomical information, diagnosing eye diseases, and drafting interpretations and follow-up plans, thereby reducing the burden on clinicians and improving access to eye care. However, limited benchmarks are available to assess LVLMs' performance in ophthalmology-specific applications. In this study, we introduce LMOD, a large-scale multimodal ophthalmology benchmark consisting of 21,993 instances across (1) five ophthalmic imaging modalities: optical coherence tomography, color fundus photographs, scanning laser ophthalmoscopy, lens photographs, and surgical scenes; (2) free-text, demographic, and disease biomarker information; and (3) primary ophthalmology-specific applications such as anatomical information understanding, disease diagnosis, and subgroup analysis. In addition, we benchmarked 13 state-of-the-art LVLM representatives from closed-source, open-source, and medical domains. The results demonstrate a significant performance drop for LVLMs in ophthalmology compared to other domains. Systematic error analysis further identified six major failure modes: misclassification, failure to abstain, inconsistent reasoning, hallucination, assertions without justification, and lack of domain-specific knowledge. In contrast, supervised neural networks specifically trained on these tasks as baselines demonstrated high accuracy. These findings underscore the pressing need for benchmarks in the development and validation of ophthalmology-specific LVLMs.

  • 9 authors
·
Oct 2, 2024

Astra: a generalizable report generation foundation model for 3D computed tomography

Interpreting computed tomography (CT) requires review of hundreds of volumetric slices and remains time-intensive and expertise-dependent. Automated CT report generation offers a promising route to improving clinical efficiency, yet the field still lacks a generalizable CT report generation foundation model that supports multi-region reporting and remains robust across external real-world cohorts. Intrinsic inconsistencies in reporting style and diagnostic terminology across cohorts make naive joint training difficult. Here we present Astra, a generalizable CT report generation foundation model developed on 90,678 thoracoabdominal CT-report pairs collected from five sites worldwide (CTRgDB), comprising 353,671 abnormalities spanning eight organ systems. By harmonizing report style and further refining diagnostic consistency via reinforcement learning, Astra achieves style-consistent and diagnostically accurate report generation across diverse anatomical regions and institutions. Evaluated on CTRgDB and six external cohorts, Astra achieves state-of-the-art performance with a 38.4% average improvement in fine-grained diagnostic metrics (P<0.001). Deployed at external clinical sites without any site-specific fine-tuning, Astra accelerated chest report drafting by 29.6% and improved abdominal report completeness by 11.3% among junior and mid-level radiologists (P<0.001). Furthermore, Astra demonstrates broad utility as a foundation for CT AI development, improving downstream diagnostic performance and scaling vision-language pretrain through high-quality report synthesis. Overall, Astra serves as a broadly accessible clinical assistant and a pivotal infrastructure for the next generation of AI-powered healthcare. The code for Astra is publicly available at https://github.com/zh-Wang-Med/Astra.

  • 22 authors
·
Jul 13

KD-OCT: Efficient Knowledge Distillation for Clinical-Grade Retinal OCT Classification

Age-related macular degeneration (AMD) and choroidal neovascularization (CNV)-related conditions are leading causes of vision loss worldwide, with optical coherence tomography (OCT) serving as a cornerstone for early detection and management. However, deploying state-of-the-art deep learning models like ConvNeXtV2-Large in clinical settings is hindered by their computational demands. Therefore, it is desirable to develop efficient models that maintain high diagnostic performance while enabling real-time deployment. In this study, a novel knowledge distillation framework, termed KD-OCT, is proposed to compress a high-performance ConvNeXtV2-Large teacher model, enhanced with advanced augmentations, stochastic weight averaging, and focal loss, into a lightweight EfficientNet-B2 student for classifying normal, drusen, and CNV cases. KD-OCT employs real-time distillation with a combined loss balancing soft teacher knowledge transfer and hard ground-truth supervision. The effectiveness of the proposed method is evaluated on the Noor Eye Hospital (NEH) dataset using patient-level cross-validation. Experimental results demonstrate that KD-OCT outperforms comparable multi-scale or feature-fusion OCT classifiers in efficiency- accuracy balance, achieving near-teacher performance with substantial reductions in model size and inference time. Despite the compression, the student model exceeds most existing frameworks, facilitating edge deployment for AMD screening. Code is available at https://github.com/erfan-nourbakhsh/KD- OCT.

  • 3 authors
·
Dec 9, 2025 2

Co-Annotator: Expert-Distilled ViT and VLM for Visual and Documentation Guidance in Age-Related Macular Degeneration

Clinical AI often optimizes predictive performance without engaging how clinicians decide where to look and what to write. We present Co-Annotator, which distills expert gaze and dictation into two guidance components: a gaze-aligned Vision Transformer producing fixation-aligned areas of interest (AOIs), and an ontology-bounded vision-language model (VLM) that pre-fills editable biomarker summaries for retinal optical coherence tomography (OCT). We first collect expert gaze and dictations (US1) to train the models, significantly improving diagnostic accuracy and biomarker generation. We then deploy the system with ophthalmology residents: a controlled resident study (US2) confirmed each modality is safe and independently beneficial, with AOI guidance producing lasting perceptual efficiency gains through post-guidance carryover and VLM guidance more than doubling biomarker documentation breadth. In a combined deployment across two academic institutions (US3), providing both modalities simultaneously produced efficiency gains that substantially exceeded either modality alone: correct diagnoses per minute increased by 40% and comment editing time fell by 67%, without compromising diagnostic accuracy. Notably, neither modality improved efficiency during guidance in US2, which makes the in-guidance efficiency gain under combined guidance in US3 the more striking result. Expert-distilled multimodal guidance can remove two distinct clinical workflow bottlenecks at once (visual search overhead and documentation burden) without compromising the diagnostic accuracy clinicians already achieve.

  • 8 authors
·
Aug 30

Unified Medical Image Pre-training in Language-Guided Common Semantic Space

Vision-Language Pre-training (VLP) has shown the merits of analysing medical images, by leveraging the semantic congruence between medical images and their corresponding reports. It efficiently learns visual representations, which in turn facilitates enhanced analysis and interpretation of intricate imaging data. However, such observation is predominantly justified on single-modality data (mostly 2D images like X-rays), adapting VLP to learning unified representations for medical images in real scenario remains an open challenge. This arises from medical images often encompass a variety of modalities, especially modalities with different various number of dimensions (e.g., 3D images like Computed Tomography). To overcome the aforementioned challenges, we propose an Unified Medical Image Pre-training framework, namely UniMedI, which utilizes diagnostic reports as common semantic space to create unified representations for diverse modalities of medical images (especially for 2D and 3D images). Under the text's guidance, we effectively uncover visual modality information, identifying the affected areas in 2D X-rays and slices containing lesion in sophisticated 3D CT scans, ultimately enhancing the consistency across various medical imaging modalities. To demonstrate the effectiveness and versatility of UniMedI, we evaluate its performance on both 2D and 3D images across 10 different datasets, covering a wide range of medical image tasks such as classification, segmentation, and retrieval. UniMedI has demonstrated superior performance in downstream tasks, showcasing its effectiveness in establishing a universal medical visual representation.

  • 9 authors
·
Jul 3, 2024

Glimpse: Generalized Locality for Scalable and Robust CT

Deep learning has become the state-of-the-art approach to medical tomographic imaging. A common approach is to feed the result of a simple inversion, for example the backprojection, to a multiscale convolutional neural network (CNN) which computes the final reconstruction. Despite good results on in-distribution test data, this often results in overfitting certain large-scale structures and poor generalization on out-of-distribution (OOD) samples. Moreover, the memory and computational complexity of multiscale CNNs scale unfavorably with image resolution, making them impractical for application at realistic clinical resolutions. In this paper, we introduce Glimpse, a local coordinate-based neural network for computed tomography which reconstructs a pixel value by processing only the measurements associated with the neighborhood of the pixel. Glimpse significantly outperforms successful CNNs on OOD samples, while achieving comparable or better performance on in-distribution test data and maintaining a memory footprint almost independent of image resolution; 5GB memory suffices to train on 1024x1024 images which is orders of magnitude less than CNNs. Glimpse is fully differentiable and can be used plug-and-play in arbitrary deep learning architectures, enabling feats such as correcting miscalibrated projection orientations. Our implementation and Google Colab demo can be accessed at https://github.com/swing-research/Glimpse.

  • 4 authors
·
Jan 1, 2024

Solving 3D Inverse Problems using Pre-trained 2D Diffusion Models

Diffusion models have emerged as the new state-of-the-art generative model with high quality samples, with intriguing properties such as mode coverage and high flexibility. They have also been shown to be effective inverse problem solvers, acting as the prior of the distribution, while the information of the forward model can be granted at the sampling stage. Nonetheless, as the generative process remains in the same high dimensional (i.e. identical to data dimension) space, the models have not been extended to 3D inverse problems due to the extremely high memory and computational cost. In this paper, we combine the ideas from the conventional model-based iterative reconstruction with the modern diffusion models, which leads to a highly effective method for solving 3D medical image reconstruction tasks such as sparse-view tomography, limited angle tomography, compressed sensing MRI from pre-trained 2D diffusion models. In essence, we propose to augment the 2D diffusion prior with a model-based prior in the remaining direction at test time, such that one can achieve coherent reconstructions across all dimensions. Our method can be run in a single commodity GPU, and establishes the new state-of-the-art, showing that the proposed method can perform reconstructions of high fidelity and accuracy even in the most extreme cases (e.g. 2-view 3D tomography). We further reveal that the generalization capacity of the proposed method is surprisingly high, and can be used to reconstruct volumes that are entirely different from the training dataset.

  • 5 authors
·
Nov 19, 2022

Can Multimodal Large Language Models Understand OCT?

Optical coherence tomography (OCT) imaging is essential for the diagnosis and treatment of retinal diseases. Although multimodal large language models (MLLMs) have demonstrated considerable potential in medical image analysis, existing benchmarks largely reduce OCT understanding to coarse-grained disease classification or isolated visual question answering, leaving the complete cognitive process from visual perception to clinical reasoning insufficiently evaluated. To address this limitation, we introduce OCT-Bench, a comprehensive benchmark dedicated to OCT image understanding. OCT-Bench comprises 10,076 high-quality multiple-choice questions constructed from 4,137 OCT images across seven public datasets. Following the real-world clinical interpretation workflow, we establish a hierarchical capability taxonomy consisting of 20 fine-grained tasks across three dimensions: Perception, Cognition, and Reasoning. These tasks cover a broad range of capabilities, including imaging attributes, retinal anatomy, lesion characteristics, spatial relationships, disease assessment, therapeutic decision-making, and prognostic management. We systematically evaluate 20 representative MLLMs, including proprietary models, open-source general-purpose models, and medical-domain models. Experimental results demonstrate that current models remain substantially short of reliable OCT understanding. Moreover, neither medical-domain adaptation nor increased model scale consistently improves performance across capability levels. OCT-Bench enables comprehensive and fine-grained evaluation of MLLMs, providing a foundation for identifying capability bottlenecks and advancing clinically grounded OCT understanding.

  • 8 authors
·
Jul 17 2

Resolution Meets Reduction: Efficient Visual Context for 3D Radiology Report Generation

Vision-language models offer a promising path toward automating radiology report generation, but applying them to full 3D CT volumes poses substantial computational challenges. Modern foundation vision encoders (VEs) can produce tens of thousands of vision tokens per scan, making the visual sequence passed to the large language model (LLM) a primary computational bottleneck. Vision-to-language projectors can compress this sequence to reduce computation, but may discard clinically relevant detail; conversely, effective compression can accommodate higher-resolution inputs while keeping the downstream token count fixed. How this vision-token budget should be allocated across input field of view, spatial resolution, and vision-to-language projection therefore remains an open design question. We systematically evaluate four heterogeneous VEs (CNN- and ViT-based), five token-reducing projectors at up to 64x compression alongside a non-reducing MLP projector baseline, and five instruction-tuned LLMs (1.7B--4B) on two large-scale CT report datasets (CT-RATE and Merlin). At matched LLM token budgets, anatomy-guided region of interest cropping is the most consistent strategy, improving clinical macro F1 in 19 of 20 settings by +3.7 points on average for the 3D ViT Primus encoder and +1.1 for the slice-based 2D ViT Curia encoder. Increasing input resolution further is strongly projector-dependent: the PerceiverResampler, paired with higher-resolution Curia features, yields the strongest configuration in the resolution study on both datasets. Our best configurations achieve state-of-the-art clinical macro F1 on the test sets, reaching 49.5 on CT-RATE and 49.0 on Merlin. Code and models will be published upon publication.

  • 13 authors
·
Aug 8

The Role of AI in Early Detection of Life-Threatening Diseases: A Retinal Imaging Perspective

Retinal imaging has emerged as a powerful, non-invasive modality for detecting and quantifying biomarkers of systemic diseases-ranging from diabetes and hypertension to Alzheimer's disease and cardiovascular disorders but current insights remain dispersed across platforms and specialties. Recent technological advances in optical coherence tomography (OCT/OCTA) and adaptive optics (AO) now deliver ultra-high-resolution scans (down to 5 {\mu}m ) with superior contrast and spatial integration, allowing early identification of microvascular abnormalities and neurodegenerative changes. At the same time, AI-driven and machine learning (ML) algorithms have revolutionized the analysis of large-scale retinal datasets, increasing sensitivity and specificity; for example, deep learning models achieve > 90 \% sensitivity for diabetic retinopathy and AUC = 0.89 for the prediction of cardiovascular risk from fundus photographs. The proliferation of mobile health technologies and telemedicine platforms further extends access, reduces costs, and facilitates community-based screening and longitudinal monitoring. Despite these breakthroughs, translation into routine practice is hindered by heterogeneous imaging protocols, limited external validation of AI models, and integration challenges within clinical workflows. In this review, we systematically synthesize the latest OCT/OCT and AO developments, AI/ML approaches, and mHealth/Tele-ophthalmology initiatives and quantify their diagnostic performance across disease domains. Finally, we propose a roadmap for multicenter protocol standardization, prospective validation trials, and seamless incorporation of retinal screening into primary and specialty care pathways-paving the way for precision prevention, early intervention, and ongoing treatment of life-threatening systemic diseases.

  • 3 authors
·
May 27, 2025

GAMMA Challenge:Glaucoma grAding from Multi-Modality imAges

Color fundus photography and Optical Coherence Tomography (OCT) are the two most cost-effective tools for glaucoma screening. Both two modalities of images have prominent biomarkers to indicate glaucoma suspected. Clinically, it is often recommended to take both of the screenings for a more accurate and reliable diagnosis. However, although numerous algorithms are proposed based on fundus images or OCT volumes in computer-aided diagnosis, there are still few methods leveraging both of the modalities for the glaucoma assessment. Inspired by the success of Retinal Fundus Glaucoma Challenge (REFUGE) we held previously, we set up the Glaucoma grAding from Multi-Modality imAges (GAMMA) Challenge to encourage the development of fundus \& OCT-based glaucoma grading. The primary task of the challenge is to grade glaucoma from both the 2D fundus images and 3D OCT scanning volumes. As part of GAMMA, we have publicly released a glaucoma annotated dataset with both 2D fundus color photography and 3D OCT volumes, which is the first multi-modality dataset for glaucoma grading. In addition, an evaluation framework is also established to evaluate the performance of the submitted methods. During the challenge, 1272 results were submitted, and finally, top-10 teams were selected to the final stage. We analysis their results and summarize their methods in the paper. Since all these teams submitted their source code in the challenge, a detailed ablation study is also conducted to verify the effectiveness of the particular modules proposed. We find many of the proposed techniques are practical for the clinical diagnosis of glaucoma. As the first in-depth study of fundus \& OCT multi-modality glaucoma grading, we believe the GAMMA Challenge will be an essential starting point for future research.

  • 29 authors
·
Feb 14, 2022

VELVET-Med: Vision and Efficient Language Pre-training for Volumetric Imaging Tasks in Medicine

Vision-and-language models (VLMs) have been increasingly explored in the medical domain, particularly following the success of CLIP in general domain. However, unlike the relatively straightforward pairing of 2D images and text, curating large-scale paired data in the medical field for volumetric modalities such as CT scans remains a challenging and time-intensive process. This difficulty often limits the performance on downstream tasks. To address these challenges, we propose a novel vision-language pre-training (VLP) framework, termed as VELVET-Med, specifically designed for limited volumetric data such as 3D CT and associated radiology reports. Instead of relying on large-scale data collection, our method focuses on the development of effective pre-training objectives and model architectures. The key contributions are: 1) We incorporate uni-modal self-supervised learning into VLP framework, which are often underexplored in the existing literature. 2) We propose a novel language encoder, termed as TriBERT, for learning multi-level textual semantics. 3) We devise the hierarchical contrastive learning to capture multi-level vision-language correspondence. Using only 38,875 scan-report pairs, our approach seeks to uncover rich spatial and semantic relationships embedded in volumetric medical images and corresponding clinical narratives, thereby enhancing the generalization ability of the learned encoders. The resulting encoders exhibit strong transferability, achieving state-of-the-art performance across a wide range of downstream tasks, including 3D segmentation, cross-modal retrieval, visual question answering, and report generation.

  • 4 authors
·
Aug 16, 2025

RISING a new framework for few-view tomographic image reconstruction with deep learning

This paper proposes a new two-step procedure for sparse-view tomographic image reconstruction. It is called RISING, since it combines an early-stopped Rapid Iterative Solver with a subsequent Iteration Network-based Gaining step. So far, regularized iterative methods have widely been used for X-ray computed tomography image reconstruction from low-sampled data, since they converge to a sparse solution in a suitable domain, as upheld by the Compressed Sensing theory. Unfortunately, their use is practically limited by their high computational cost which imposes to perform only a few iterations in the available time for clinical exams. Data-driven methods, using neural networks to post-process a coarse and noisy image obtained from geometrical algorithms, have been recently studied and appreciated for both their computational speed and accurate reconstructions. However, there is no evidence, neither theoretically nor numerically, that neural networks based algorithms solve the mathematical inverse problem modeling the tomographic reconstruction process. In our two-step approach, the first phase executes very few iterations of a regularized model-based algorithm whereas the second step completes the missing iterations by means of a neural network. The resulting hybrid deep-variational framework preserves the convergence properties of the iterative method and, at the same time, it exploits the computational speed and flexibility of a data-driven approach. Experiments performed on a simulated and a real data set confirm the numerical and visual accuracy of the reconstructed RISING images in short computational times.

  • 3 authors
·
Jan 24, 2022

OCTA-500: A Retinal Dataset for Optical Coherence Tomography Angiography Study

Optical coherence tomography angiography (OCTA) is a novel imaging modality that has been widely utilized in ophthalmology and neuroscience studies to observe retinal vessels and microvascular systems. However, publicly available OCTA datasets remain scarce. In this paper, we introduce the largest and most comprehensive OCTA dataset dubbed OCTA-500, which contains OCTA imaging under two fields of view (FOVs) from 500 subjects. The dataset provides rich images and annotations including two modalities (OCT/OCTA volumes), six types of projections, four types of text labels (age / gender / eye / disease) and seven types of segmentation labels (large vessel/capillary/artery/vein/2D FAZ/3D FAZ/retinal layers). Then, we propose a multi-object segmentation task called CAVF, which integrates capillary segmentation, artery segmentation, vein segmentation, and FAZ segmentation under a unified framework. In addition, we optimize the 3D-to-2D image projection network (IPN) to IPN-V2 to serve as one of the segmentation baselines. Experimental results demonstrate that IPN-V2 achieves an ~10% mIoU improvement over IPN on CAVF task. Finally, we further study the impact of several dataset characteristics: the training set size, the model input (OCT/OCTA, 3D volume/2D projection), the baseline networks, and the diseases. The dataset and code are publicly available at: https://ieee-dataport.org/open-access/octa-500.

  • 10 authors
·
Dec 14, 2020

XOCT: Enhancing OCT to OCTA Translation via Cross-Dimensional Supervised Multi-Scale Feature Learning

Optical Coherence Tomography Angiography (OCTA) and its derived en-face projections provide high-resolution visualization of the retinal and choroidal vasculature, which is critical for the rapid and accurate diagnosis of retinal diseases. However, acquiring high-quality OCTA images is challenging due to motion sensitivity and the high costs associated with software modifications for conventional OCT devices. Moreover, current deep learning methods for OCT-to-OCTA translation often overlook the vascular differences across retinal layers and struggle to reconstruct the intricate, dense vascular details necessary for reliable diagnosis. To overcome these limitations, we propose XOCT, a novel deep learning framework that integrates Cross-Dimensional Supervision (CDS) with a Multi-Scale Feature Fusion (MSFF) network for layer-aware vascular reconstruction. Our CDS module leverages 2D layer-wise en-face projections, generated via segmentation-weighted z-axis averaging, as supervisory signals to compel the network to learn distinct representations for each retinal layer through fine-grained, targeted guidance. Meanwhile, the MSFF module enhances vessel delineation through multi-scale feature extraction combined with a channel reweighting strategy, effectively capturing vascular details at multiple spatial scales. Our experiments on the OCTA-500 dataset demonstrate XOCT's improvements, especially for the en-face projections which are significant for clinical evaluation of retinal pathologies, underscoring its potential to enhance OCTA accessibility, reliability, and diagnostic value for ophthalmic disease detection and monitoring. The code is available at https://github.com/uci-cbcl/XOCT.

  • 6 authors
·
Sep 9, 2025

XGLASS: X-Ray, Gaze and Language Assisted Slice Sequencing for CT Volumes

Vision-language models (VLMs) achieve remarkable performance on 2D medical images, such as X-rays or pathology images, while 3D VLMs that directly process CT/MRI volumes lag behind due to limited 3D training data and the predominance of 2D foundation architectures. To leverage powerful 2D VLMs for analyzing medical volumes, which contain hundreds of slices, it is therefore necessary to focus only on those few slices, which are diagnostically relevant. To enable such a prioritization, we propose XGLASS, a method that transfers medical expertise from 2D X-rays to 3D CT for task-aware slice prioritization. XGLASS uses disease-conditioned importance maps derived from language-aligned radiologist gaze on X-rays and spatially aligns them with coronal CT projections, bringing gaze priors and CT content into a shared 2D representation. The fused gaze-prior/CT projection is then used to predict a disease-specific ordering of axial slices, prioritizing diagnostically relevant slices. XGLASS significantly improves budgeted retrieval over 2D and 3D-native baselines, achieving a top-10 hit rate up to 75.9% for the best-performing disease. In practice, this means that after inspecting only the top 10 slices (4.17% of a 240-slice scan), XGLASS identifies a diagnostically relevant slice in more than 75% of cases. For downstream slice-wise finding classification, an XGLASS-selected 30-slice candidate set reduces model calls by 87.5% while improving F1 by 11.3 percentage points over all-slice inference, 4.2 points over the strongest 2D selector, and remains competitive with 3D-native selectors while requiring up to 130.8 times less time and 10.9 times less GPU memory per finding, supporting its use as a lightweight preselector for volumetric CT analysis. The code and pretrained checkpoint are available on https://github.com/michaelgloeckler/XGLASS.

  • 2 authors
·
Oct 18

SegBook: A Simple Baseline and Cookbook for Volumetric Medical Image Segmentation

Computed Tomography (CT) is one of the most popular modalities for medical imaging. By far, CT images have contributed to the largest publicly available datasets for volumetric medical segmentation tasks, covering full-body anatomical structures. Large amounts of full-body CT images provide the opportunity to pre-train powerful models, e.g., STU-Net pre-trained in a supervised fashion, to segment numerous anatomical structures. However, it remains unclear in which conditions these pre-trained models can be transferred to various downstream medical segmentation tasks, particularly segmenting the other modalities and diverse targets. To address this problem, a large-scale benchmark for comprehensive evaluation is crucial for finding these conditions. Thus, we collected 87 public datasets varying in modality, target, and sample size to evaluate the transfer ability of full-body CT pre-trained models. We then employed a representative model, STU-Net with multiple model scales, to conduct transfer learning across modalities and targets. Our experimental results show that (1) there may be a bottleneck effect concerning the dataset size in fine-tuning, with more improvement on both small- and large-scale datasets than medium-size ones. (2) Models pre-trained on full-body CT demonstrate effective modality transfer, adapting well to other modalities such as MRI. (3) Pre-training on the full-body CT not only supports strong performance in structure detection but also shows efficacy in lesion detection, showcasing adaptability across target tasks. We hope that this large-scale open evaluation of transfer learning can direct future research in volumetric medical image segmentation.

  • 10 authors
·
Nov 21, 2024 2

Learning to Distill Global Representation for Sparse-View CT

Sparse-view computed tomography (CT) -- using a small number of projections for tomographic reconstruction -- enables much lower radiation dose to patients and accelerated data acquisition. The reconstructed images, however, suffer from strong artifacts, greatly limiting their diagnostic value. Current trends for sparse-view CT turn to the raw data for better information recovery. The resultant dual-domain methods, nonetheless, suffer from secondary artifacts, especially in ultra-sparse view scenarios, and their generalization to other scanners/protocols is greatly limited. A crucial question arises: have the image post-processing methods reached the limit? Our answer is not yet. In this paper, we stick to image post-processing methods due to great flexibility and propose global representation (GloRe) distillation framework for sparse-view CT, termed GloReDi. First, we propose to learn GloRe with Fourier convolution, so each element in GloRe has an image-wide receptive field. Second, unlike methods that only use the full-view images for supervision, we propose to distill GloRe from intermediate-view reconstructed images that are readily available but not explored in previous literature. The success of GloRe distillation is attributed to two key components: representation directional distillation to align the GloRe directions, and band-pass-specific contrastive distillation to gain clinically important details. Extensive experiments demonstrate the superiority of the proposed GloReDi over the state-of-the-art methods, including dual-domain ones. The source code is available at https://github.com/longzilicart/GloReDi.

  • 5 authors
·
Aug 16, 2023

VisionUnite: A Vision-Language Foundation Model for Ophthalmology Enhanced with Clinical Knowledge

The need for improved diagnostic methods in ophthalmology is acute, especially in the underdeveloped regions with limited access to specialists and advanced equipment. Therefore, we introduce VisionUnite, a novel vision-language foundation model for ophthalmology enhanced with clinical knowledge. VisionUnite has been pretrained on an extensive dataset comprising 1.24 million image-text pairs, and further refined using our proposed MMFundus dataset, which includes 296,379 high-quality fundus image-text pairs and 889,137 simulated doctor-patient dialogue instances. Our experiments indicate that VisionUnite outperforms existing generative foundation models such as GPT-4V and Gemini Pro. It also demonstrates diagnostic capabilities comparable to junior ophthalmologists. VisionUnite performs well in various clinical scenarios including open-ended multi-disease diagnosis, clinical explanation, and patient interaction, making it a highly versatile tool for initial ophthalmic disease screening. VisionUnite can also serve as an educational aid for junior ophthalmologists, accelerating their acquisition of knowledge regarding both common and underrepresented ophthalmic conditions. VisionUnite represents a significant advancement in ophthalmology, with broad implications for diagnostics, medical education, and understanding of disease mechanisms. The source code is at https://github.com/HUANGLIZI/VisionUnite.

  • 8 authors
·
Aug 5, 2024

Resolution-Agnostic Neural Operators for Multi-Rate Sparse-View CT

Sparse-view Computed Tomography (CT) reconstructs images from a limited number of X-ray projections to reduce radiation and scanning time, which is an ill-posed inverse problem. Existing methods achieve high-fidelity reconstructions but overfit to a fixed acquisition setup, failing to generalize well across sampling rates. For example, convolutional neural networks (CNNs) use the same kernels across resolutions, leading to artifacts when data resolution changes. This is a critical limitation in clinical practice, where acquisition sampling settings vary across organs and diagnostic protocols. We propose Computed Tomography neural Operator (CTO), the first neural operator (NO) framework for CT reconstruction. CTO extends learning from fixed discretized grids to continuous function space, enabling a single model to generalize across measurement sampling rates without retraining. We also propose new NO architectural designs for CT: (i) a dual-domain NO architecture in both sinogram and image spaces, capturing complementary spatial-frequency information, and (ii) rotation-equivariant DIScrete-COntinuous convolutions (DISCO) that exploit the rotational structure inherent in tomographic acquisition. Empirically, CTO outperforms CNNs (> 3.4dB PSNR gain) and other baselines in multi-resolution settings across multiple CT datasets. Compared to state-of-the-art diffusion methods, CTO has 500x faster inference with an average 3dB gain. CTO further demonstrates strong out-of-distribution robustness, maintaining gains under cross-dataset transfer and noisy sinogram conditions. Ablation studies also validate each design choice. CTO establishes neural operators as a principled and practical paradigm for flexible, discretization-agnostic CT reconstruction. Our code is available at https://github.com/neuraloperator/sparse_ct.

  • 4 authors
·
Aug 6

OCTolyzer: Fully automatic toolkit for segmentation and feature extracting in optical coherence tomography and scanning laser ophthalmoscopy data

Optical coherence tomography (OCT) and scanning laser ophthalmoscopy (SLO) of the eye has become essential to ophthalmology and the emerging field of oculomics, thus requiring a need for transparent, reproducible, and rapid analysis of this data for clinical research and the wider research community. Here, we introduce OCTolyzer, the first open-source toolkit for retinochoroidal analysis in OCT/SLO data. It features two analysis suites for OCT and SLO data, facilitating deep learning-based anatomical segmentation and feature extraction of the cross-sectional retinal and choroidal layers and en face retinal vessels. We describe OCTolyzer and evaluate the reproducibility of its OCT choroid analysis. At the population level, metrics for choroid region thickness were highly reproducible, with a mean absolute error (MAE)/Pearson correlation for macular volume choroid thickness (CT) of 6.7mum/0.99, macular B-scan CT of 11.6mum/0.99, and peripapillary CT of 5.0mum/0.99. Macular choroid vascular index (CVI) also showed strong reproducibility, with MAE/Pearson for volume CVI yielding 0.0271/0.97 and B-scan CVI 0.0130/0.91. At the eye level, measurement noise for regional and vessel metrics was below 5% and 20% of the population's variability, respectively. Outliers were caused by poor-quality B-scans with thick choroids and invisible choroid-sclera boundary. Processing times on a laptop CPU were under three seconds for macular/peripapillary B-scans and 85 seconds for volume scans. OCTolyzer can convert OCT/SLO data into reproducible and clinically meaningful retinochoroidal features and will improve the standardisation of ocular measurements in OCT/SLO image analysis, requiring no specialised training or proprietary software to be used. OCTolyzer is freely available here: https://github.com/jaburke166/OCTolyzer.

  • 12 authors
·
Jul 19, 2024

EyeVQA: Benchmarking Ophthalmic Vision-Language Models from Recognition to Spatial Grounding

Vision-language models (VLMs) have shown increasing potential for medical image understanding, yet their capabilities in ophthalmic imaging remain insufficiently characterized. Existing ophthalmic datasets are typically designed for individual diseases or specialized tasks, making it difficult to systematically evaluate whether VLMs can move beyond disease recognition toward comparative reasoning and fine-grained spatial grounding. We introduce EyeVQA, a unified visual question answering benchmark for comprehensive evaluation of ophthalmic VLMs. EyeVQA is constructed from 21 available ophthalmic datasets and contains 20,000 question-answer pairs spanning six disease groups and seven question types: Single-Choice, Multi-Select, Variable-Select, True-False, Ranking, Point Location, and Bounding Box. Gold answers are deterministically derived from source-provided diagnoses, severity grades, clinical findings, segmentation masks, bounding boxes, and anatomical landmarks, enabling reproducible evaluation without relying on model-generated annotations. Notably, 44.5% of the questions require reasoning across multiple images, extending evaluation beyond conventional single-image medical VQA. We benchmark fourteen representative general-purpose, scientific, and medically specialized VLMs under a unified zero-shot protocol. The best-performing model only achieves an overall score of 62.8, while substantial gaps remain in spatial grounding and cross-task generalization. These results highlight the limitations of current VLMs in comprehensive ophthalmic visual understanding and establish EyeVQA as a diagnostic benchmark for developing more reliable and spatially grounded ophthalmic multimodal models. The project page is available at https://github.com/PKUTHM/EyeVQA.

  • 10 authors
·
Sep 25

Intensive Vision-guided Network for Radiology Report Generation

Automatic radiology report generation is booming due to its huge application potential for the healthcare industry. However, existing computer vision and natural language processing approaches to tackle this problem are limited in two aspects. First, when extracting image features, most of them neglect multi-view reasoning in vision and model single-view structure of medical images, such as space-view or channel-view. However, clinicians rely on multi-view imaging information for comprehensive judgment in daily clinical diagnosis. Second, when generating reports, they overlook context reasoning with multi-modal information and focus on pure textual optimization utilizing retrieval-based methods. We aim to address these two issues by proposing a model that better simulates clinicians' perspectives and generates more accurate reports. Given the above limitation in feature extraction, we propose a Globally-intensive Attention (GIA) module in the medical image encoder to simulate and integrate multi-view vision perception. GIA aims to learn three types of vision perception: depth view, space view, and pixel view. On the other hand, to address the above problem in report generation, we explore how to involve multi-modal signals to generate precisely matched reports, i.e., how to integrate previously predicted words with region-aware visual content in next word prediction. Specifically, we design a Visual Knowledge-guided Decoder (VKGD), which can adaptively consider how much the model needs to rely on visual information and previously predicted text to assist next word prediction. Hence, our final Intensive Vision-guided Network (IVGN) framework includes a GIA-guided Visual Encoder and the VKGD. Experiments on two commonly-used datasets IU X-Ray and MIMIC-CXR demonstrate the superior ability of our method compared with other state-of-the-art approaches.

  • 8 authors
·
Feb 6, 2024

MM-DINOv2: Adapting Foundation Models for Multi-Modal Medical Image Analysis

Vision foundation models like DINOv2 demonstrate remarkable potential in medical imaging despite their origin in natural image domains. However, their design inherently works best for uni-modal image analysis, limiting their effectiveness for multi-modal imaging tasks that are common in many medical fields, such as neurology and oncology. While supervised models perform well in this setting, they fail to leverage unlabeled datasets and struggle with missing modalities, a frequent challenge in clinical settings. To bridge these gaps, we introduce MM-DINOv2, a novel and efficient framework that adapts the pre-trained vision foundation model DINOv2 for multi-modal medical imaging. Our approach incorporates multi-modal patch embeddings, enabling vision foundation models to effectively process multi-modal imaging data. To address missing modalities, we employ full-modality masking, which encourages the model to learn robust cross-modality relationships. Furthermore, we leverage semi-supervised learning to harness large unlabeled datasets, enhancing both the accuracy and reliability of medical predictions. Applied to glioma subtype classification from multi-sequence brain MRI, our method achieves a Matthews Correlation Coefficient (MCC) of 0.6 on an external test set, surpassing state-of-the-art supervised approaches by +11.1%. Our work establishes a scalable and robust solution for multi-modal medical imaging tasks, leveraging powerful vision foundation models pre-trained on natural images while addressing real-world clinical challenges such as missing data and limited annotations.

TUM-AIMED AIMED
·
Sep 8, 2025

OLIVES Dataset: Ophthalmic Labels for Investigating Visual Eye Semantics

Clinical diagnosis of the eye is performed over multifarious data modalities including scalar clinical labels, vectorized biomarkers, two-dimensional fundus images, and three-dimensional Optical Coherence Tomography (OCT) scans. Clinical practitioners use all available data modalities for diagnosing and treating eye diseases like Diabetic Retinopathy (DR) or Diabetic Macular Edema (DME). Enabling usage of machine learning algorithms within the ophthalmic medical domain requires research into the relationships and interactions between all relevant data over a treatment period. Existing datasets are limited in that they neither provide data nor consider the explicit relationship modeling between the data modalities. In this paper, we introduce the Ophthalmic Labels for Investigating Visual Eye Semantics (OLIVES) dataset that addresses the above limitation. This is the first OCT and near-IR fundus dataset that includes clinical labels, biomarker labels, disease labels, and time-series patient treatment information from associated clinical trials. The dataset consists of 1268 near-IR fundus images each with at least 49 OCT scans, and 16 biomarkers, along with 4 clinical labels and a disease diagnosis of DR or DME. In total, there are 96 eyes' data averaged over a period of at least two years with each eye treated for an average of 66 weeks and 7 injections. We benchmark the utility of OLIVES dataset for ophthalmic data as well as provide benchmarks and concrete research directions for core and emerging machine learning paradigms within medical image analysis.

  • 6 authors
·
Sep 22, 2022

GAZE: Grounded Agentic Zero-shot Evaluation with Viewer-Level Tools and Literature Retrieval on Rare Brain MRI

Vision-language models (VLMs) read an image and produce text in a single forward pass, whereas radiologists typically inspect an image several times and consult the literature before writing a report. We introduce GAZE (Grounded Agentic Zero-shot Evaluation), a framework that lets a medical VLM work in this iterative way by calling viewer-level tools (zoom, windowing, contrast, edge detection) and two retrieval tools backed by the U.S. National Library of Medicine (PubMed for medical literature, Open-i for radiological images), with structured outputs validated against a schema and full tool-call traces recorded for auditability. On NOVA, a benchmark of 906 brain MRI cases covering 281 rare neurological conditions, GAZE reaches 58.2 mean average precision (mAP) at intersection-over-union (IoU) 0.3 for lesion localisation and 34.9% Top-1 diagnostic accuracy under a joint protocol that scores captioning, diagnosis, and localisation from the image alone, without task-specific fine-tuning. Before any tool is used, structured prompting and schema-validated outputs already improve over the published Gemini 2.0 Flash baseline (20.2 to 29.4 mAP@0.3), so framework design is itself an experimental variable. Tool use helps rare pathologies disproportionately: the fraction of cases with IoU > 0.3 rises from 17% to 58% for diagnoses with three or fewer examples versus 25% to 68% for common conditions (geq10 cases), with gains tracking engagement (Gemini 3 Flash: Cohen's d = 0.79, 11.8 tool calls per case; Gemini 2.0 Flash: tools used in 8.2% of cases, no significant benefit). Retrieval ablations additionally reveal a model-dependent trade-off in which gains in diagnosis can coincide with losses in localisation, reinforcing the case for joint evaluation of diagnosis, localisation, and captioning in medical VLMs.

  • 3 authors
·
Apr 24

OrthoDoc: Multimodal Large Language Model for Assisting Diagnosis in Computed Tomography

Multimodal large language models (MLLMs) have achieved significant success in the general field of image processing. Their emerging task generalization and freeform conversational capabilities can greatly facilitate medical diagnostic assistance, helping patients better understand their conditions and enhancing doctor-patient trust. Computed Tomography (CT) is a non-invasive imaging technique used to capture the internal mechanisms of a patient's condition and is widely utilized. However, in past research, the complex textural features of this imaging data have made accurate interpretation by algorithms challenging, impeding the performance of general LLMs in diagnostic assistance. To address this, we developed OrthoDoc, a MLLM designed for CT diagnostics. OrthoDoc is trained on 120,000 CT images and diagnostic reports and includes a Retrieval-Augmented Generation (RAG) module capable of effectively mitigating model hallucinations. This module is informed by extensive medical literature, textbooks, and explanatory data. Thus, OrthoDoc not only processes complex CT images but also stores, understands, and reasons over medical knowledge and language. In extensive experiments, OrthoDoc outperforms commercial models led by GPT-4, demonstrating superior diagnostic capabilities and accuracy. Specifically, OrthoDoc significantly surpasses existing models in the diagnosis of common orthopedic conditions such as fractures, arthritis, and tumors. Additionally, OrthoDoc exhibits robust generalization and stability when handling rare and complex cases.

  • 2 authors
·
Aug 30, 2024

Enhanced SegNet with Integrated Grad-CAM for Interpretable Retinal Layer Segmentation in OCT Images

Optical Coherence Tomography (OCT) is essential for diagnosing conditions such as glaucoma, diabetic retinopathy, and age-related macular degeneration. Accurate retinal layer segmentation enables quantitative biomarkers critical for clinical decision-making, but manual segmentation is time-consuming and variable, while conventional deep learning models often lack interpretability. This work proposes an improved SegNet-based deep learning framework for automated and interpretable retinal layer segmentation. Architectural innovations, including modified pooling strategies, enhance feature extraction from noisy OCT images, while a hybrid loss function combining categorical cross-entropy and Dice loss improves performance for thin and imbalanced retinal layers. Gradient-weighted Class Activation Mapping (Grad-CAM) is integrated to provide visual explanations, allowing clinical validation of model decisions. Trained and validated on the Duke OCT dataset, the framework achieved 95.77% validation accuracy, a Dice coefficient of 0.9446, and a Jaccard Index (IoU) of 0.8951. Class-wise results confirmed robust performance across most layers, with challenges remaining for thinner boundaries. Grad-CAM visualizations highlighted anatomically relevant regions, aligning segmentation with clinical biomarkers and improving transparency. By combining architectural improvements, a customized hybrid loss, and explainable AI, this study delivers a high-performing SegNet-based framework that bridges the gap between accuracy and interpretability. The approach offers strong potential for standardizing OCT analysis, enhancing diagnostic efficiency, and fostering clinical trust in AI-driven ophthalmic tools.

  • 2 authors
·
Sep 9, 2025

NV-Reason-CT: 3D Visual Language Model for CT Analysis

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

  • 16 authors
·
Sep 22

Latent Diffusion Model for Medical Image Standardization and Enhancement

Computed tomography (CT) serves as an effective tool for lung cancer screening, diagnosis, treatment, and prognosis, providing a rich source of features to quantify temporal and spatial tumor changes. Nonetheless, the diversity of CT scanners and customized acquisition protocols can introduce significant inconsistencies in texture features, even when assessing the same patient. This variability poses a fundamental challenge for subsequent research that relies on consistent image features. Existing CT image standardization models predominantly utilize GAN-based supervised or semi-supervised learning, but their performance remains limited. We present DiffusionCT, an innovative score-based DDPM model that operates in the latent space to transform disparate non-standard distributions into a standardized form. The architecture comprises a U-Net-based encoder-decoder, augmented by a DDPM model integrated at the bottleneck position. First, the encoder-decoder is trained independently, without embedding DDPM, to capture the latent representation of the input data. Second, the latent DDPM model is trained while keeping the encoder-decoder parameters fixed. Finally, the decoder uses the transformed latent representation to generate a standardized CT image, providing a more consistent basis for downstream analysis. Empirical tests on patient CT images indicate notable improvements in image standardization using DiffusionCT. Additionally, the model significantly reduces image noise in SPAD images, further validating the effectiveness of DiffusionCT for advanced imaging tasks.

  • 7 authors
·
Oct 8, 2023

Novel quantitative indicators of digital ophthalmoscopy image quality

With the advent of smartphone indirect ophthalmoscopy, teleophthalmology - the use of specialist ophthalmology assets at a distance from the patient - has experienced a breakthrough, promising enormous benefits especially for healthcare in distant, inaccessible or opthalmologically underserved areas, where specialists are either unavailable or too few in number. However, accurate teleophthalmology requires high-quality ophthalmoscopic imagery. This paper considers three feature families - statistical metrics, gradient-based metrics and wavelet transform coefficient derived indicators - as possible metrics to identify unsharp or blurry images. By using standard machine learning techniques, the suitability of these features for image quality assessment is confirmed, albeit on a rather small data set. With the increased availability and decreasing cost of digital ophthalmoscopy on one hand and the increased prevalence of diabetic retinopathy worldwide on the other, creating tools that can determine whether an image is likely to be diagnostically suitable can play a significant role in accelerating and streamlining the teleophthalmology process. This paper highlights the need for more research in this area, including the compilation of a diverse database of ophthalmoscopic imagery, annotated with quality markers, to train the Point of Acquisition error detection algorithms of the future.

  • 1 authors
·
Mar 6, 2019

Expert-level vision-language foundation model for real-world radiology and comprehensive evaluation

Radiology is a vital and complex component of modern clinical workflow and covers many tasks. Recently, vision-language (VL) foundation models in medicine have shown potential in processing multimodal information, offering a unified solution for various radiology tasks. However, existing studies either pre-trained VL models on natural data or did not fully integrate vision-language architecture and pretraining, often neglecting the unique multimodal complexity in radiology images and their textual contexts. Additionally, their practical applicability in real-world scenarios remains underexplored. Here, we present RadFound, a large and open-source vision-language foundation model tailored for radiology, that is trained on the most extensive dataset of over 8.1 million images and 250,000 image-text pairs, covering 19 major organ systems and 10 imaging modalities. To establish expert-level multimodal perception and generation capabilities, RadFound introduces an enhanced vision encoder to capture intra-image local features and inter-image contextual information, and a unified cross-modal learning design tailored to radiology. To fully assess the models' capability, we construct a benchmark, RadVLBench, including radiology interpretation tasks like medical vision-language question-answering, as well as text generation tasks ranging from captioning to report generation. We also propose a human evaluation framework. When evaluated on the real-world benchmark involving three representative modalities, 2D images (chest X-rays), multi-view images (mammograms), and 3D images (thyroid CT scans), RadFound significantly outperforms other VL foundation models on both quantitative metrics and human evaluation. In summary, the development of RadFound represents an advancement in radiology generalists, demonstrating broad applicability potential for integration into clinical workflows.

  • 9 authors
·
Sep 24, 2024

A General Model for Retinal Segmentation and Quantification

Retinal imaging is fast, non-invasive, and widely available, offering quantifiable structural and vascular signals for ophthalmic and systemic health assessment. This accessibility creates an opportunity to study how quantitative retinal phenotypes relate to ocular and systemic diseases. However, such analyses remain difficult at scale due to the limited availability of public multi-label datasets and the lack of a unified segmentation-to-quantification pipeline. We present RetSAM, a general retinal segmentation and quantification framework for fundus imaging. It delivers robust multi-target segmentation and standardized biomarker extraction, supporting downstream ophthalmologic studies and oculomics correlation analyses. Trained on over 200,000 fundus images, RetSAM supports three task categories and segments five anatomical structures, four retinal phenotypic patterns, and more than 20 distinct lesion types. It converts these segmentation results into over 30 standardized biomarkers that capture structural morphology, vascular geometry, and degenerative changes. Trained with a multi-stage strategy using both private and public fundus data, RetSAM achieves superior segmentation performance on 17 public datasets. It improves on prior best methods by 3.9 percentage points in DSC on average, with up to 15 percentage points on challenging multi-task benchmarks, and generalizes well across diverse populations, imaging devices, and clinical settings. The resulting biomarkers enable systematic correlation analyses across major ophthalmic diseases, including diabetic retinopathy, age-related macular degeneration, glaucoma, and pathologic myopia. Together, RetSAM transforms fundus images into standardized, interpretable quantitative phenotypes, enabling large-scale ophthalmic research and translation.

MedVision: Dataset and Benchmark for Quantitative Medical Image Analysis

Current vision-language models (VLMs) in medicine are primarily designed for categorical question answering (e.g., "Is this normal or abnormal?") or qualitative descriptive tasks. However, clinical decision-making often relies on quantitative assessments, such as measuring the size of a tumor or the angle of a joint, from which physicians draw their own diagnostic conclusions. This quantitative reasoning capability remains underexplored and poorly supported in existing VLMs. In this work, we introduce MedVision, a large-scale dataset and benchmark specifically designed to evaluate and improve VLMs on quantitative medical image analysis. MedVision spans 22 public datasets covering diverse anatomies and modalities, with 30.8 million image-annotation pairs. We focus on three representative quantitative tasks: (1) detection of anatomical structures and abnormalities, (2) tumor/lesion (T/L) size estimation, and (3) angle/distance (A/D) measurement. Our benchmarks show that current off-the-shelf VLMs perform poorly on these tasks. However, with supervised fine-tuning on MedVision, we significantly enhance their performance across detection, T/L estimation, and A/D measurement, demonstrating reduced error rates and improved precision. This work provides a foundation for developing VLMs with robust quantitative reasoning capabilities in medical imaging. Code and data are available at https://medvision-vlm.github.io.

  • 6 authors
·
Nov 23, 2025

RetinaLogos: Fine-Grained Synthesis of High-Resolution Retinal Images Through Captions

The scarcity of high-quality, labelled retinal imaging data, which presents a significant challenge in the development of machine learning models for ophthalmology, hinders progress in the field. Existing methods for synthesising Colour Fundus Photographs (CFPs) largely rely on predefined disease labels, which restricts their ability to generate images that reflect fine-grained anatomical variations, subtle disease stages, and diverse pathological features beyond coarse class categories. To overcome these challenges, we first introduce an innovative pipeline that creates a large-scale, captioned retinal dataset comprising 1.4 million entries, called RetinaLogos-1400k. Specifically, RetinaLogos-1400k uses the visual language model(VLM) to describe retinal conditions and key structures, such as optic disc configuration, vascular distribution, nerve fibre layers, and pathological features. Building on this dataset, we employ a novel three-step training framework, RetinaLogos, which enables fine-grained semantic control over retinal images and accurately captures different stages of disease progression, subtle anatomical variations, and specific lesion types. Through extensive experiments, our method demonstrates superior performance across multiple datasets, with 62.07% of text-driven synthetic CFPs indistinguishable from real ones by ophthalmologists. Moreover, the synthetic data improves accuracy by 5%-10% in diabetic retinopathy grading and glaucoma detection. Codes are available at https://github.com/uni-medical/retina-text2cfp.

  • 15 authors
·
May 19, 2025 1

Active View Selection with Perturbed Gaussian Ensemble for Tomographic Reconstruction

Sparse-view computed tomography (CT) is critical for reducing radiation exposure to patients. Recent advances in radiative 3D Gaussian Splatting (3DGS) have enabled fast and accurate sparse-view CT reconstruction. Despite these algorithmic advancements, practical reconstruction fidelity remains fundamentally bounded by the quality of the captured data, raising the crucial yet underexplored problem of X-ray active view selection. Existing active view selection methods are primarily designed for natural-light scenes and fail to capture the unique geometric ambiguities and physical attenuation properties inherent in X-ray imaging. In this paper, we present Perturbed Gaussian Ensemble, an active view selection framework that integrates uncertainty modeling with sequential decision-making, tailored for X-ray Gaussian Splatting. Specifically, we identify low-density Gaussian primitives that are likely to be uncertain and apply stochastic density scaling to construct an ensemble of plausible Gaussian density fields. For each candidate projection, we measure the structural variance of the ensemble predictions and select the one with the highest variance as the next best view. Extensive experimental results on arbitrary-trajectory CT benchmarks demonstrate that our density-guided perturbation strategy effectively eliminates geometric artifacts and consistently outperforms existing baselines in progressive tomographic reconstruction under unified view selection protocols.

  • 6 authors
·
Jun 29

Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CT

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time and may mitigate motion artifacts. However, angular undersampling provides insufficient information to determine the image uniquely and stably. Limited-angle CT, arising from restricted angular coverage, produces strongly directional information loss associated with the missing angular range. In both settings, image directions may be strongly observed, weakly constrained, or unobservable, leading to severe ill-posedness and reconstruction ambiguity. Existing diffusion-based approaches incorporate measurement information through likelihood guidance, data-consistency operations, or range-null-space corrections. However, they do not generally use the continuously varying measurement sensitivity of the acquisition to jointly shape both reconstruction updates and stochastic exploration. We propose a geometry-aware diffusion-guided stochastic reconstruction framework for sparse-view and limited-angle CT. Its central component is a regularized noise-weighted pullback metric constructed from the CT forward operator and measurement-noise covariance. This metric continuously adapts both the measurement-aware update and stochastic exploration according to directional measurement sensitivity, suppressing changes along strongly constrained directions while permitting greater exploration along weakly constrained and unobservable directions. We complement this geometry-aware update with a regularized data-consistency correction and approximately null-space-restricted stochastic perturbations, implemented matrix-free using forward and backprojection operations together with conjugate-gradient solves. Experiments on sparse-view, noisy, and limited-angle CT demonstrate competitive reconstruction quality, strong measurement consistency, and spatially resolved empirical uncertainty estimates.

  • 3 authors
·
Oct 4

Dia-LLaMA: Towards Large Language Model-driven CT Report Generation

Medical report generation has achieved remarkable advancements yet has still been faced with several challenges. First, the inherent imbalance in the distribution of normal and abnormal cases may lead models to exhibit a biased focus on normal samples, resulting in unreliable diagnoses. Second, the frequent occurrence of common template sentences in the reports may overwhelm the critical abnormal information. Moreover, existing works focus on 2D chest X-rays, leaving CT report generation underexplored due to the high-dimensional nature of CT images and the limited availability of CT-report pairs. Recently, LLM has shown a great ability to generate reliable answers with appropriate prompts, which shed light on addressing the aforementioned challenges. In this paper, we propose Dia-LLaMA, a framework to adapt the LLaMA2-7B for CT report generation by incorporating diagnostic information as guidance prompts. Considering the high dimension of CT, we leverage a pre-trained ViT3D with perceiver to extract the visual information. To tailor the LLM for report generation and emphasize abnormality, we extract additional diagnostic information by referring to a disease prototype memory bank, which is updated during training to capture common disease representations. Furthermore, we introduce disease-aware attention to enable the model to adjust attention for different diseases. Experiments on the chest CT dataset demonstrated that our proposed method outperformed previous methods and achieved state-of-the-art on both clinical efficacy performance and natural language generation metrics. The code will be made publically available.

  • 4 authors
·
Mar 24, 2024

A Quantitative Evaluation of Dense 3D Reconstruction of Sinus Anatomy from Monocular Endoscopic Video

Generating accurate 3D reconstructions from endoscopic video is a promising avenue for longitudinal radiation-free analysis of sinus anatomy and surgical outcomes. Several methods for monocular reconstruction have been proposed, yielding visually pleasant 3D anatomical structures by retrieving relative camera poses with structure-from-motion-type algorithms and fusion of monocular depth estimates. However, due to the complex properties of the underlying algorithms and endoscopic scenes, the reconstruction pipeline may perform poorly or fail unexpectedly. Further, acquiring medical data conveys additional challenges, presenting difficulties in quantitatively benchmarking these models, understanding failure cases, and identifying critical components that contribute to their precision. In this work, we perform a quantitative analysis of a self-supervised approach for sinus reconstruction using endoscopic sequences paired with optical tracking and high-resolution computed tomography acquired from nine ex-vivo specimens. Our results show that the generated reconstructions are in high agreement with the anatomy, yielding an average point-to-mesh error of 0.91 mm between reconstructions and CT segmentations. However, in a point-to-point matching scenario, relevant for endoscope tracking and navigation, we found average target registration errors of 6.58 mm. We identified that pose and depth estimation inaccuracies contribute equally to this error and that locally consistent sequences with shorter trajectories generate more accurate reconstructions. These results suggest that achieving global consistency between relative camera poses and estimated depths with the anatomy is essential. In doing so, we can ensure proper synergy between all components of the pipeline for improved reconstructions that will facilitate clinical application of this innovative technology.

  • 12 authors
·
Oct 22, 2023

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

Multimodal large language models (MLLMs) can answer clinical questions about medical images, but trustworthy use requires visual grounding: models should localize the pathology they report rather than rely on spurious shortcuts. Whether MLLMs can visually ground clinical findings in retinal optical coherence tomography (OCT), the most widely used imaging modality in ophthalmology, remains largely unexplored. To address this gap, we introduce RetinaGroundBench, the first benchmark for biomarker visual grounding in retinal OCT. It comprises 815 B-scans exhaustively annotated by ophthalmologists with 4,537 bounding boxes covering 13 biomarkers across 8 diseases. Because MLLMs often fragment a single lesion into multiple partial predictions, we propose AggIoU, a metric that evaluates whether the union of overlapping predicted boxes covers the annotated region. Across 27 open-source MLLMs (0.8-38B parameters), we find that visual grounding remains largely unsolved: the best general-purpose model achieves a macro F1 of just 23.7%, with consistently low recall, despite reaching up to 73% balanced accuracy on biomarker presence questions. To narrow this gap, we developed RetGrounder, an MLLM fine-tuned using an OCT-specific strategy integrating grounding and textual information. Despite its relatively small size (8B), RetGrounder improves grounding F1 to 33.9%, a 43% relative improvement. Our benchmark provides a reference point for measuring progress in the field of OCT diagnosis with MLLMs.

  • 9 authors
·
Oct 21

Sinogram upsampling using Primal-Dual UNet for undersampled CT and radial MRI reconstruction

Computed tomography and magnetic resonance imaging are two widely used clinical imaging modalities for non-invasive diagnosis. However, both of these modalities come with certain problems. CT uses harmful ionising radiation, and MRI suffers from slow acquisition speed. Both problems can be tackled by undersampling, such as sparse sampling. However, such undersampled data leads to lower resolution and introduces artefacts. Several techniques, including deep learning based methods, have been proposed to reconstruct such data. However, the undersampled reconstruction problem for these two modalities was always considered as two different problems and tackled separately by different research works. This paper proposes a unified solution for both sparse CT and undersampled radial MRI reconstruction, achieved by applying Fourier transform-based pre-processing on the radial MRI and then finally reconstructing both modalities using sinogram upsampling combined with filtered back-projection. The Primal-Dual network is a deep learning based method for reconstructing sparsely-sampled CT data. This paper introduces Primal-Dual UNet, which improves the Primal-Dual network in terms of accuracy and reconstruction speed. The proposed method resulted in an average SSIM of 0.932\textpm0.021 while performing sparse CT reconstruction for fan-beam geometry with a sparsity level of 16, achieving a statistically significant improvement over the previous model, which resulted in 0.919\textpm0.016. Furthermore, the proposed model resulted in 0.903\textpm0.019 and 0.957\textpm0.023 average SSIM while reconstructing undersampled brain and abdominal MRI data with an acceleration factor of 16, respectively - statistically significant improvements over the original model, which resulted in 0.867\textpm0.025 and 0.949\textpm0.025.

  • 5 authors
·
Dec 26, 2021

OmniCT: Towards a Unified Slice-Volume LVLM for Comprehensive CT Analysis

Computed Tomography (CT) is one of the most widely used and diagnostically information-dense imaging modalities, covering critical organs such as the heart, lungs, liver, and colon. Clinical interpretation relies on both slice-driven local features (e.g., sub-centimeter nodules, lesion boundaries) and volume-driven spatial representations (e.g., tumor infiltration, inter-organ anatomical relations). However, existing Large Vision-Language Models (LVLMs) remain fragmented in CT slice versus volumetric understanding: slice-driven LVLMs show strong generalization but lack cross-slice spatial consistency, while volume-driven LVLMs explicitly capture volumetric semantics but suffer from coarse granularity and poor compatibility with slice inputs. The absence of a unified modeling paradigm constitutes a major bottleneck for the clinical translation of medical LVLMs. We present OmniCT, a powerful unified slice-volume LVLM for CT scenarios, which makes three contributions: (i) Spatial Consistency Enhancement (SCE): volumetric slice composition combined with tri-axial positional embedding that introduces volumetric consistency, and an MoE hybrid projection enables efficient slice-volume adaptation; (ii) Organ-level Semantic Enhancement (OSE): segmentation and ROI localization explicitly align anatomical regions, emphasizing lesion- and organ-level semantics; (iii) MedEval-CT: the largest slice-volume CT dataset and hybrid benchmark integrates comprehensive metrics for unified evaluation. OmniCT consistently outperforms existing methods with a substantial margin across diverse clinical tasks and satisfies both micro-level detail sensitivity and macro-level spatial reasoning. More importantly, it establishes a new paradigm for cross-modal medical imaging understanding. Our project is available at https://github.com/ZJU4HealthCare/OmniCT.

  • 15 authors
·
Feb 17

MedSyn: Text-guided Anatomy-aware Synthesis of High-Fidelity 3D CT Images

This paper introduces an innovative methodology for producing high-quality 3D lung CT images guided by textual information. While diffusion-based generative models are increasingly used in medical imaging, current state-of-the-art approaches are limited to low-resolution outputs and underutilize radiology reports' abundant information. The radiology reports can enhance the generation process by providing additional guidance and offering fine-grained control over the synthesis of images. Nevertheless, expanding text-guided generation to high-resolution 3D images poses significant memory and anatomical detail-preserving challenges. Addressing the memory issue, we introduce a hierarchical scheme that uses a modified UNet architecture. We start by synthesizing low-resolution images conditioned on the text, serving as a foundation for subsequent generators for complete volumetric data. To ensure the anatomical plausibility of the generated samples, we provide further guidance by generating vascular, airway, and lobular segmentation masks in conjunction with the CT images. The model demonstrates the capability to use textual input and segmentation tasks to generate synthesized images. The results of comparative assessments indicate that our approach exhibits superior performance compared to the most advanced models based on GAN and diffusion techniques, especially in accurately retaining crucial anatomical features such as fissure lines, airways, and vascular structures. This innovation introduces novel possibilities. This study focuses on two main objectives: (1) the development of a method for creating images based on textual prompts and anatomical components, and (2) the capability to generate new images conditioning on anatomical elements. The advancements in image generation can be applied to enhance numerous downstream tasks.

  • 5 authors
·
Oct 5, 2023

Improving visual image reconstruction from human brain activity using latent diffusion models via multiple decoded inputs

The integration of deep learning and neuroscience has been advancing rapidly, which has led to improvements in the analysis of brain activity and the understanding of deep learning models from a neuroscientific perspective. The reconstruction of visual experience from human brain activity is an area that has particularly benefited: the use of deep learning models trained on large amounts of natural images has greatly improved its quality, and approaches that combine the diverse information contained in visual experiences have proliferated rapidly in recent years. In this technical paper, by taking advantage of the simple and generic framework that we proposed (Takagi and Nishimoto, CVPR 2023), we examine the extent to which various additional decoding techniques affect the performance of visual experience reconstruction. Specifically, we combined our earlier work with the following three techniques: using decoded text from brain activity, nonlinear optimization for structural image reconstruction, and using decoded depth information from brain activity. We confirmed that these techniques contributed to improving accuracy over the baseline. We also discuss what researchers should consider when performing visual reconstruction using deep generative models trained on large datasets. Please check our webpage at https://sites.google.com/view/stablediffusion-with-brain/. Code is also available at https://github.com/yu-takagi/StableDiffusionReconstruction.

  • 2 authors
·
Jun 20, 2023

Brain decoding: toward real-time reconstruction of visual perception

In the past five years, the use of generative and foundational AI systems has greatly improved the decoding of brain activity. Visual perception, in particular, can now be decoded from functional Magnetic Resonance Imaging (fMRI) with remarkable fidelity. This neuroimaging technique, however, suffers from a limited temporal resolution (approx0.5 Hz) and thus fundamentally constrains its real-time usage. Here, we propose an alternative approach based on magnetoencephalography (MEG), a neuroimaging device capable of measuring brain activity with high temporal resolution (approx5,000 Hz). For this, we develop an MEG decoding model trained with both contrastive and regression objectives and consisting of three modules: i) pretrained embeddings obtained from the image, ii) an MEG module trained end-to-end and iii) a pretrained image generator. Our results are threefold: Firstly, our MEG decoder shows a 7X improvement of image-retrieval over classic linear decoders. Second, late brain responses to images are best decoded with DINOv2, a recent foundational image model. Third, image retrievals and generations both suggest that high-level visual features can be decoded from MEG signals, although the same approach applied to 7T fMRI also recovers better low-level features. Overall, these results, while preliminary, provide an important step towards the decoding -- in real-time -- of the visual processes continuously unfolding within the human brain.

  • 3 authors
·
Oct 18, 2023

Boosting Vision Semantic Density with Anatomy Normality Modeling for Medical Vision-language Pre-training

Vision-language pre-training (VLP) has great potential for developing multifunctional and general medical diagnostic capabilities. However, aligning medical images with a low signal-to-noise ratio (SNR) to reports with a high SNR presents a semantic density gap, leading to visual alignment bias. In this paper, we propose boosting vision semantic density to improve alignment effectiveness. On one hand, we enhance visual semantics through disease-level vision contrastive learning, which strengthens the model's ability to differentiate between normal and abnormal samples for each anatomical structure. On the other hand, we introduce an anatomical normality modeling method to model the distribution of normal samples for each anatomy, leveraging VQ-VAE for reconstructing normal vision embeddings in the latent space. This process amplifies abnormal signals by leveraging distribution shifts in abnormal samples, enhancing the model's perception and discrimination of abnormal attributes. The enhanced visual representation effectively captures the diagnostic-relevant semantics, facilitating more efficient and accurate alignment with the diagnostic report. We conduct extensive experiments on two chest CT datasets, CT-RATE and Rad-ChestCT, and an abdominal CT dataset, MedVL-CT69K, and comprehensively evaluate the diagnosis performance across multiple tasks in the chest and abdominal CT scenarios, achieving state-of-the-art zero-shot performance. Notably, our method achieved an average AUC of 84.9% across 54 diseases in 15 organs, significantly surpassing existing methods. Additionally, we demonstrate the superior transfer learning capabilities of our pre-trained model. Code is available at https://github.com/alibaba-damo-academy/ViSD-Boost.

  • 11 authors
·
Jul 31, 2025

Towards Unifying Medical Vision-and-Language Pre-training via Soft Prompts

Medical vision-and-language pre-training (Med-VLP) has shown promising improvements on many downstream medical tasks owing to its applicability to extracting generic representations from medical images and texts. Practically, there exist two typical types, i.e., the fusion-encoder type and the dual-encoder type, depending on whether a heavy fusion module is used. The former is superior at multi-modal tasks owing to the sufficient interaction between modalities; the latter is good at uni-modal and cross-modal tasks due to the single-modality encoding ability. To take advantage of these two types, we propose an effective yet straightforward scheme named PTUnifier to unify the two types. We first unify the input format by introducing visual and textual prompts, which serve as a feature bank that stores the most representative images/texts. By doing so, a single model could serve as a foundation model that processes various tasks adopting different input formats (i.e., image-only, text-only, and image-text-pair). Furthermore, we construct a prompt pool (instead of static ones) to improve diversity and scalability. Experimental results show that our approach achieves state-of-the-art results on a broad range of tasks, spanning uni-modal tasks (i.e., image/text classification and text summarization), cross-modal tasks (i.e., image-to-text generation and image-text/text-image retrieval), and multi-modal tasks (i.e., visual question answering), demonstrating the effectiveness of our approach. Note that the adoption of prompts is orthogonal to most existing Med-VLP approaches and could be a beneficial and complementary extension to these approaches.

  • 5 authors
·
Feb 17, 2023

Seeing Like Radiologists: Context- and Gaze-Guided Vision-Language Pretraining for Chest X-rays

Despite recent advances in medical vision-language pretraining, existing models still struggle to capture the diagnostic workflow: radiographs are typically treated as context-agnostic images, while radiologists' gaze -- a crucial cue for visual reasoning -- remains largely underexplored by existing methods. These limitations hinder the modeling of disease-specific patterns and weaken cross-modal alignment. To bridge this gap, we introduce CoGaze, a Context- and Gaze-guided vision-language pretraining framework for chest X-rays. We first propose a context-infused vision encoder that models how radiologists integrate clinical context -- including patient history, symptoms, and diagnostic intent -- to guide diagnostic reasoning. We then present a multi-level supervision paradigm that (1) enforces intra- and inter-modal semantic alignment through hybrid-positive contrastive learning, (2) injects diagnostic priors via disease-aware cross-modal representation learning, and (3) leverages radiologists' gaze as probabilistic priors to guide attention toward diagnostically salient regions. Extensive experiments demonstrate that CoGaze consistently outperforms state-of-the-art methods across diverse tasks, achieving up to +2.0% CheXbertF1 and +1.2% BLEU2 for free-text and structured report generation, +23.2% AUROC for zero-shot classification, and +12.2% Precision@1 for image-text retrieval. Code is available at https://github.com/mk-runner/CoGaze.

  • 8 authors
·
Mar 26

Anatomy-VLM: A Fine-grained Vision-Language Model for Medical Interpretation

Accurate disease interpretation from radiology remains challenging due to imaging heterogeneity. Achieving expert-level diagnostic decisions requires integration of subtle image features with clinical knowledge. Yet major vision-language models (VLMs) treat images as holistic entities and overlook fine-grained image details that are vital for disease diagnosis. Clinicians analyze images by utilizing their prior medical knowledge and identify anatomical structures as important region of interests (ROIs). Inspired from this human-centric workflow, we introduce Anatomy-VLM, a fine-grained, vision-language model that incorporates multi-scale information. First, we design a model encoder to localize key anatomical features from entire medical images. Second, these regions are enriched with structured knowledge for contextually-aware interpretation. Finally, the model encoder aligns multi-scale medical information to generate clinically-interpretable disease prediction. Anatomy-VLM achieves outstanding performance on both in- and out-of-distribution datasets. We also validate the performance of Anatomy-VLM on downstream image segmentation tasks, suggesting that its fine-grained alignment captures anatomical and pathology-related knowledge. Furthermore, the Anatomy-VLM's encoder facilitates zero-shot anatomy-wise interpretation, providing its strong expert-level clinical interpretation capabilities.

  • 4 authors
·
Nov 11, 2025

OCTCube-M: A 3D multimodal optical coherence tomography foundation model for retinal and systemic diseases with cross-cohort and cross-device validation

We present OCTCube-M, a 3D OCT-based multi-modal foundation model for jointly analyzing OCT and en face images. OCTCube-M first developed OCTCube, a 3D foundation model pre-trained on 26,685 3D OCT volumes encompassing 1.62 million 2D OCT images. It then exploits a novel multi-modal contrastive learning framework COEP to integrate other retinal imaging modalities, such as fundus autofluorescence and infrared retinal imaging, into OCTCube, efficiently extending it into multi-modal foundation models. OCTCube achieves best performance on predicting 8 retinal diseases, demonstrating strong generalizability on cross-cohort, cross-device and cross-modality prediction. OCTCube can also predict cross-organ nodule malignancy (CT) and low cardiac ejection fraction as well as systemic diseases, such as diabetes and hypertension, revealing its wide applicability beyond retinal diseases. We further develop OCTCube-IR using COEP with 26,685 OCT and IR image pairs. OCTCube-IR can accurately retrieve between OCT and IR images, allowing joint analysis between 3D and 2D retinal imaging modalities. Finally, we trained a tri-modal foundation model OCTCube-EF from 4 million 2D OCT images and 400K en face retinal images. OCTCube-EF attains the best performance on predicting the growth rate of geographic atrophy (GA) across datasets collected from 6 multi-center global trials conducted in 23 countries. This improvement is statistically equivalent to running a clinical trial with more than double the size of the original study. Our analysis based on another retrospective case study reveals OCTCube-EF's ability to avoid false positive Phase-III results according to its accurate treatment effect estimation on the Phase-II results. In sum, OCTCube-M is a 3D multi-modal foundation model framework that integrates OCT and other retinal imaging modalities revealing substantial diagnostic and prognostic benefits.

  • 12 authors
·
Aug 20, 2024

A Foundation LAnguage-Image model of the Retina (FLAIR): Encoding expert knowledge in text supervision

Foundation vision-language models are currently transforming computer vision, and are on the rise in medical imaging fueled by their very promising generalization capabilities. However, the initial attempts to transfer this new paradigm to medical imaging have shown less impressive performances than those observed in other domains, due to the significant domain shift and the complex, expert domain knowledge inherent to medical-imaging tasks. Motivated by the need for domain-expert foundation models, we present FLAIR, a pre-trained vision-language model for universal retinal fundus image understanding. To this end, we compiled 37 open-access, mostly categorical fundus imaging datasets from various sources, with up to 97 different target conditions and 284,660 images. We integrate the expert's domain knowledge in the form of descriptive textual prompts, during both pre-training and zero-shot inference, enhancing the less-informative categorical supervision of the data. Such a textual expert's knowledge, which we compiled from the relevant clinical literature and community standards, describes the fine-grained features of the pathologies as well as the hierarchies and dependencies between them. We report comprehensive evaluations, which illustrate the benefit of integrating expert knowledge and the strong generalization capabilities of FLAIR under difficult scenarios with domain shifts or unseen categories. When adapted with a lightweight linear probe, FLAIR outperforms fully-trained, dataset-focused models, more so in the few-shot regimes. Interestingly, FLAIR outperforms by a large margin more generalist, larger-scale image-language models, which emphasizes the potential of embedding experts' domain knowledge and the limitations of generalist models in medical imaging.

  • 5 authors
·
Aug 15, 2023

Zeus: Zero-shot LLM Instruction for Union Segmentation in Multimodal Medical Imaging

Medical image segmentation has achieved remarkable success through the continuous advancement of UNet-based and Transformer-based foundation backbones. However, clinical diagnosis in the real world often requires integrating domain knowledge, especially textual information. Conducting multimodal learning involves visual and text modalities shown as a solution, but collecting paired vision-language datasets is expensive and time-consuming, posing significant challenges. Inspired by the superior ability in numerous cross-modal tasks for Large Language Models (LLMs), we proposed a novel Vision-LLM union framework to address the issues. Specifically, we introduce frozen LLMs for zero-shot instruction generation based on corresponding medical images, imitating the radiology scanning and report generation process. {To better approximate real-world diagnostic processes}, we generate more precise text instruction from multimodal radiology images (e.g., T1-w or T2-w MRI and CT). Based on the impressive ability of semantic understanding and rich knowledge of LLMs. This process emphasizes extracting special features from different modalities and reunion the information for the ultimate clinical diagnostic. With generated text instruction, our proposed union segmentation framework can handle multimodal segmentation without prior collected vision-language datasets. To evaluate our proposed method, we conduct comprehensive experiments with influential baselines, the statistical results and the visualized case study demonstrate the superiority of our novel method.}

  • 5 authors
·
Apr 8, 2025

EyeFound: A Multimodal Generalist Foundation Model for Ophthalmic Imaging

Artificial intelligence (AI) is vital in ophthalmology, tackling tasks like diagnosis, classification, and visual question answering (VQA). However, existing AI models in this domain often require extensive annotation and are task-specific, limiting their clinical utility. While recent developments have brought about foundation models for ophthalmology, they are limited by the need to train separate weights for each imaging modality, preventing a comprehensive representation of multi-modal features. This highlights the need for versatile foundation models capable of handling various tasks and modalities in ophthalmology. To address this gap, we present EyeFound, a multimodal foundation model for ophthalmic images. Unlike existing models, EyeFound learns generalizable representations from unlabeled multimodal retinal images, enabling efficient model adaptation across multiple applications. Trained on 2.78 million images from 227 hospitals across 11 ophthalmic modalities, EyeFound facilitates generalist representations and diverse multimodal downstream tasks, even for detecting challenging rare diseases. It outperforms previous work RETFound in diagnosing eye diseases, predicting systemic disease incidents, and zero-shot multimodal VQA. EyeFound provides a generalizable solution to improve model performance and lessen the annotation burden on experts, facilitating widespread clinical AI applications for retinal imaging.

  • 9 authors
·
May 18, 2024

LMOD+: A Comprehensive Multimodal Dataset and Benchmark for Developing and Evaluating Multimodal Large Language Models in Ophthalmology

Vision-threatening eye diseases pose a major global health burden, with timely diagnosis limited by workforce shortages and restricted access to specialized care. While multimodal large language models (MLLMs) show promise for medical image interpretation, advancing MLLMs for ophthalmology is hindered by the lack of comprehensive benchmark datasets suitable for evaluating generative models. We present a large-scale multimodal ophthalmology benchmark comprising 32,633 instances with multi-granular annotations across 12 common ophthalmic conditions and 5 imaging modalities. The dataset integrates imaging, anatomical structures, demographics, and free-text annotations, supporting anatomical structure recognition, disease screening, disease staging, and demographic prediction for bias evaluation. This work extends our preliminary LMOD benchmark with three major enhancements: (1) nearly 50% dataset expansion with substantial enlargement of color fundus photography; (2) broadened task coverage including binary disease diagnosis, multi-class diagnosis, severity classification with international grading standards, and demographic prediction; and (3) systematic evaluation of 24 state-of-the-art MLLMs. Our evaluations reveal both promise and limitations. Top-performing models achieved ~58% accuracy in disease screening under zero-shot settings, and performance remained suboptimal for challenging tasks like disease staging. We will publicly release the dataset, curation pipeline, and leaderboard to potentially advance ophthalmic AI applications and reduce the global burden of vision-threatening diseases.

  • 16 authors
·
Mar 17

Disentanglement and Assessment of Shortcuts in Ophthalmological Retinal Imaging Exams

Diabetic retinopathy (DR) is a leading cause of vision loss in working-age adults. While screening reduces the risk of blindness, traditional imaging is often costly and inaccessible. Artificial intelligence (AI) algorithms present a scalable diagnostic solution, but concerns regarding fairness and generalization persist. This work evaluates the fairness and performance of image-trained models in DR prediction, as well as the impact of disentanglement as a bias mitigation technique, using the diverse mBRSET fundus dataset. Three models, ConvNeXt V2, DINOv2, and Swin V2, were trained on macula images to predict DR and sensitive attributes (SAs) (e.g., age and gender/sex). Fairness was assessed between subgroups of SAs, and disentanglement was applied to reduce bias. All models achieved high DR prediction performance in diagnosing (up to 94% AUROC) and could reasonably predict age and gender/sex (91% and 77% AUROC, respectively). Fairness assessment suggests disparities, such as a 10% AUROC gap between age groups in DINOv2. Disentangling SAs from DR prediction had varying results, depending on the model selected. Disentanglement improved DINOv2 performance (2% AUROC gain), but led to performance drops in ConvNeXt V2 and Swin V2 (7% and 3%, respectively). These findings highlight the complexity of disentangling fine-grained features in fundus imaging and emphasize the importance of fairness in medical imaging AI to ensure equitable and reliable healthcare solutions.

  • 5 authors
·
Jul 13, 2025

Med-StepBench: A Hierarchical Reasoning Framework for Evaluating Hallucinations in Medical Vision-Language Models

Large vision-language models (VLMs) demonstrate strong performance in medical image understanding, but frequently generate clinically plausible yet incorrect statements, raising significant safety concerns. Existing medical hallucination benchmarks primarily focus on 2D imaging with one-shot diagnostic questions, offering limited insight into whether predictions are grounded in correct localization and abnormality identification, allowing critical reasoning errors to remain hidden behind seemingly correct diagnoses. We introduce Med-StepBench, the first large-scale benchmark for step-wise hallucination detection in 3D oncological PET/CT, comprising over 12,000 images and more than 1,000,000 image-statement pairs across volumetric and multi-view 2D data, which decomposes clinical reasoning into four expert-designed diagnostic stages. Using clinician-verified annotations, we perform the first step-level evaluation of general-purpose and medical VLMs, revealing systematic failure modes obscured by aggregate accuracy metrics. Furthermore, we show that current VLMs are highly susceptible to adversarial yet clinically plausible intermediate explanations, which significantly amplify hallucinations despite contradictory visual evidence. Together, our findings highlight fundamental limitations in grounding multi-step clinical reasoning and establish Med-StepBench as a rigorous benchmark for developing safer and more reliable medical VLMs.

  • 11 authors
·
May 10

Revisiting Unreasonable Effectiveness of Data in Deep Learning Era

The success of deep learning in vision can be attributed to: (a) models with high capacity; (b) increased computational power; and (c) availability of large-scale labeled data. Since 2012, there have been significant advances in representation capabilities of the models and computational capabilities of GPUs. But the size of the biggest dataset has surprisingly remained constant. What will happen if we increase the dataset size by 10x or 100x? This paper takes a step towards clearing the clouds of mystery surrounding the relationship between `enormous data' and visual deep learning. By exploiting the JFT-300M dataset which has more than 375M noisy labels for 300M images, we investigate how the performance of current vision tasks would change if this data was used for representation learning. Our paper delivers some surprising (and some expected) findings. First, we find that the performance on vision tasks increases logarithmically based on volume of training data size. Second, we show that representation learning (or pre-training) still holds a lot of promise. One can improve performance on many vision tasks by just training a better base model. Finally, as expected, we present new state-of-the-art results for different vision tasks including image classification, object detection, semantic segmentation and human pose estimation. Our sincere hope is that this inspires vision community to not undervalue the data and develop collective efforts in building larger datasets.

  • 4 authors
·
Jul 10, 2017

Fundus-R1: Training a Fundus-Reading MLLM with Knowledge-Aware Reasoning on Public Data

Fundus imaging such as CFP, OCT and UWF is crucial for the early detection of retinal anomalies and diseases. Fundus image understanding, due to its knowledge-intensive nature, poses a challenging vision-language task. An emerging approach to addressing the task is to post-train a generic multimodal large language model (MLLM), either by supervised finetuning (SFT) or by reinforcement learning with verifiable rewards (RLVR), on a considerable amount of in-house samples paired with high-quality clinical reports. However, these valuable samples are not publicly accessible, which not only hinders reproducibility but also practically limits research to few players. To overcome the barrier, we make a novel attempt to train a reasoning-enhanced fundus-reading MLLM, which we term Fundus-R1, using exclusively public datasets, wherein over 94\% of the data are annotated with only image-level labels. Our technical contributions are two-fold. First, we propose a RAG-based method for composing image-specific, knowledge-aware reasoning traces. Such auto-generated traces link visual findings identified by a generic MLLM to the image labels in terms of ophthalmic knowledge. Second, we enhance RLVR with a process reward that encourages self-consistency of the generated reasoning trace in each rollout. Extensive experiments on three fundus-reading benchmarks, i.e., FunBench, Omni-Fundus and GMAI-Fundus, show that Fundus-R1 clearly outperforms multiple baselines, including its generic counterpart (Qwen2.5-VL) and a stronger edition post-trained without using the generated traces. This work paves the way for training powerful fundus-reading MLLMs with publicly available data.

  • 9 authors
·
Apr 8

GaMO: Geometry-aware Multi-view Diffusion Outpainting for Sparse-View 3D Reconstruction

Recent advances in 3D reconstruction have achieved remarkable progress in high-quality scene capture from dense multi-view imagery, yet struggle when input views are limited. Various approaches, including regularization techniques, semantic priors, and geometric constraints, have been implemented to address this challenge. Latest diffusion-based methods have demonstrated substantial improvements by generating novel views from new camera poses to augment training data, surpassing earlier regularization and prior-based techniques. Despite this progress, we identify three critical limitations in these state-of-the-art approaches: inadequate coverage beyond known view peripheries, geometric inconsistencies across generated views, and computationally expensive pipelines. We introduce GaMO (Geometry-aware Multi-view Outpainter), a framework that reformulates sparse-view reconstruction through multi-view outpainting. Instead of generating new viewpoints, GaMO expands the field of view from existing camera poses, which inherently preserves geometric consistency while providing broader scene coverage. Our approach employs multi-view conditioning and geometry-aware denoising strategies in a zero-shot manner without training. Extensive experiments on Replica and ScanNet++ demonstrate state-of-the-art reconstruction quality across 3, 6, and 9 input views, outperforming prior methods in PSNR and LPIPS, while achieving a 25times speedup over SOTA diffusion-based methods with processing time under 10 minutes. Project page: https://yichuanh.github.io/GaMO/

  • 5 authors
·
Dec 31, 2025 3