id stringlengths 12 16 | title stringlengths 6 140 | description stringlengths 76 139k | cpes listlengths 0 0 | cvss_v4_0 null | cvss_v3_1 float64 2.5 10 ⌀ | cvss_v3_0 float64 1.9 10 ⌀ | cvss_v2_0 null |
|---|---|---|---|---|---|---|---|
ICSA-18-221-02 | NetComm Wireless 4G LTE Light Industrial M2M Router | The device allowsaccess to configuration files and profiles without authenticating the user.CVE-2018-14782 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). A cross-site request forgery condition can occur, allowing... | [] | null | null | 9.8 | null |
ICSA-17-208-02 | Mirion Technologies Telemetry Enabled Devices | An unchangeable, factory-set key is included in the 900 MHz transmitter firmware.CVE-2017-9649 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). Decryption of data is possible at the hardware level.CVE-2017-9645 has b... | [] | null | null | 5 | null |
ICSA-18-317-07 | Siemens SIMATIC IT Production Suite | An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user... | [] | null | null | 7.7 | null |
ICSA-21-355-02 | Horner Automation Cscape EnvisionRV | This vulnerability can be exploited by parsing maliciously crafted project files. The issues result from the lack of proper validation of user-supplied data, which can result in reads and writes past the end of allocated data structures. User interaction is required to exploit this vulnerability as an attacker must tri... | [] | null | null | 7.8 | null |
ICSA-24-060-01 | Delta Electronics CNCSoft-B | Delta Electronics CNCSoft-B versions 1.0.0.4 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code. | [] | null | 7.8 | null | null |
ICSA-21-320-01 | FATEK Automation WinProladder | The affected product is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.CVE-2021-43554 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The a... | [] | null | null | 7.8 | null |
ICSA-17-353-02 | PEPPERL+FUCHS/ecom instruments WLAN Capable Devices using the WPA2 Protocol | Multiple products are affected by key reinstallation attacks known as KRACK. The four-way hand shake traffic in the Wi-Fi Protected Access WPA and WPA2 protocol can be manipulated to allow nonce reuse resulting in key reinstallation. This could allow an attacker to execute a man-in-the-middle attack, enabling the attac... | [] | null | null | 8.1 | null |
ICSA-18-128-03 | Siemens Siveillance VMS Video Mobile App | Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the commu... | [] | null | null | 4.8 | null |
ICSA-20-070-04 | ICSA-20-070-04_Johnson Controls Kantech EntraPass | An issue with an API may allow an attacker to upload and execute malicious code with system-level privileges.CVE-2019-7589 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-22-111-01 | Delta Electronics ASDA-Soft | The affected product does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.CVE-2022-1402 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The af... | [] | null | null | 7.8 | null |
ICSA-23-033-04 | Delta Electronics DVW-W02W2-E2 | The web server of the affected device is vulnerable to authenticated command injection via POST parameters. A threat actor could gain full access to the underlying operating system (OS) of the device. If the device is acting as a key device in an industrial network, or controls various critical equipment via serial por... | [] | null | 9.9 | null | null |
ICSA-23-143-01 | Hitachi Energy’s AFS65x, AFS67x, AFR67x and AFF66x Products | The libexpat library is incorporated in the AFS, AFR and AFF products family. Versions of libexpat before 2.4.9 have a use-after-free in the do-Content function in xmlparse.c. Successful exploitation of this vulnerability could lead to disclosure of sensitive information, addition or modification of data, or a denial-o... | [] | null | null | 7.5 | null |
ICSA-22-284-02 | Daikin Holdings Singapore | This vulnerability allows a remote attacker to obtain user login credentials, login to SVMPC, and fully control the system.CVE-2022-41653 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). This vulnerability allows r... | [] | null | null | 7.5 | null |
ICSA-19-122-03 | Sierra Wireless AirLink ALEOS (Update B) | A specially crafted authenticated HTTP request can inject arbitrary commands, resulting in remote code execution.CVE-2018-4061 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H). Activating SNMPD outside of the WebUI ... | [] | null | null | 5.9 | null |
ICSA-21-315-07 | Siemens Nucleus RTOS-based APOGEE and TALON Products (Update C) | ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004). CVE-2021-31344 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N). The total length of a... | [] | null | 7.5 | null | null |
ICSA-20-273-03 | B&R Automation SiteManager and GateManager | An authenticated adversary can read service configuration and other sensitive information and abuse this information for malicious activities on SiteManager instances.CVE-2020-11641 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C... | [] | null | null | 4.3 | null |
ICSA-23-248-01 | Fujitsu Limited Real-time Video Transmission Gear "IP series" | The credentials of Fujitsu Limited Real-time Video Transmission Gear "IP series" for factory testing may be obtained by reverse engineering and other methods. | [] | null | null | 5.9 | null |
ICSA-18-282-06 | Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server | An attacker may be able to use MAC addresses to enumerate potential Cloud IDs. Using this ID, the attacker can discover and connect to valid devices using one of the supported apps.CVE-2018-17917 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC... | [] | null | null | 8.1 | null |
ICSA-20-100-01 | Rockwell Automation RSLinx Classic | An authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.CVE-2020-10642 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C... | [] | null | null | 8.8 | null |
ICSA-18-081-01 | Siemens SIMATIC WinCC OA UI Mobile App | Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could... | [] | null | null | 5.1 | null |
ICSA-22-172-03 | Phoenix Contact Classic Line Controllers | The affected product lacks a function to check integrity and authenticity of uploaded logic, which could allow an attacker to execute malicious code on the device.CVE-2022-31800 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C... | [] | null | null | 9.8 | null |
ICSA-21-238-02 | Annke Network Video Recorder | The affected products are vulnerable to a stack-based buffer overflow, which allows an unauthorized remote attacker to execute arbitrary code with the same privileges as the server user (root).CVE-2021-32941 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string... | [] | null | null | 9.4 | null |
ICSA-22-195-03 | Siemens SIMATIC MV500 Devices | The web session management of affected devices does not invalidate session ids in certain logout scenarios. This could allow an authenticated remote attacker to hijack other users' sessions. Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker... | [] | null | 7.5 | null | null |
ICSA-17-339-01 | Siemens Industrial Products (Update S) | Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually. | [] | null | 7.5 | null | null |
ICSA-23-131-03 | Siemens Siveillance | The Event Server component of affected applications deserializes data without sufficient validations. This could allow an authenticated remote attacker to execute code on the affected system. The Management Server component of affected applications deserializes data without sufficient validations. This could allow an a... | [] | null | 9.9 | null | null |
ICSA-21-278-01 | Mitsubishi Electric GOT and Tension Controller (Update A) | An attacker could send specially crafted packets cause to cause several different denial-of-service conditions due to the improper handling of exceptional conditions.CVE-2021-20602 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:... | [] | null | null | 7.5 | null |
ICSMA-18-219-02 | Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A) | Communications between the pump and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.CVE-2018-10634 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been assigned;... | [] | null | null | 5.3 | null |
ICSA-18-305-02 | Schneider Electric Software Update (SESU) (Update A) | The product uses a fixed or controlled search path to find resources. An attacker with local access could place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code.CVE-2018-7799 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been ca... | [] | null | null | 7.8 | null |
ICSA-22-349-03 | Siemens Multiple Denial of Service Vulnerabilities in Industrial Products | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of servi... | [] | null | 4.9 | null | null |
ICSA-23-096-04 | Korenix Jetwave | Korenix JetWave 4200 Series 1.3.0 and JetWave 3000 Series 1.6.0 are vulnerable to command injection. An attacker could modify the file_name parameter to execute commands as root. CVE-2023-23294 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/P... | [] | null | null | 6.5 | null |
ICSA-18-046-03 | Schneider Electric IGSS Mobile | IGSS Mobile app lacks certificate pinning during the TLS/SSL connection establishing process. This issue could allow an attacker to execute a man-in-the-middle attack. CVE-2017-9968 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:R/S... | [] | null | null | 6 | null |
ICSA-21-068-04 | Siemens SINEMA Remote Connect Server | The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights. Unpriviledged users can access services when guessing the url. An attacker could impact... | [] | null | 6.3 | null | null |
ICSA-18-095-03 | LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA | A structured exception handler overflow vulnerability has been identified that may allow code execution. CVE-2018-5463 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 7 | null |
ICSA-21-238-01 | Johnson Controls Controlled Electronic Management Systems CEM Systems AC2000 | Under certain conditions, the application does not perform an adequate authorization check for functionality that requires a provable user identity.CVE-2021-27663 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N). | [] | null | null | 8.2 | null |
ICSA-19-087-01 | Rockwell Automation PowerFlex 525 AC Drives | A remote, unauthenticated threat actor can repeatedly send specific CIP packets to an affected PowerFlex 525 drive, which may allow disruption of the availability of the device.CVE-2018-19282 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/P... | [] | null | null | 7.5 | null |
ICSA-23-061-03 | Rittal CMC III Access systems | A malicious actor can clone access cards used to open control cabinets secured with Rittal CMC III locks. CVE-2022-40633 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been calculated; the CVSS vector string is (AV:P/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N). | [] | null | null | 4.8 | null |
ICSA-19-099-03 | Siemens Industrial Products with OPC UA (Update H) | Specially crafted network packets sent to affected devices on Port 4840/TCP could allow an unauthenticated remote attacker to cause a denial-of-service condition in the OPC communication or crash the device.
An attacker with network access to the affected systems could exploit the vulnerability. Successful exploitatio... | [] | null | 7.5 | null | null |
ICSA-22-179-03 | Advantech iView | The affected product is vulnerable to multiple SQL injections, which may allow an unauthorized attacker to disclose information.CVE-2022-2135 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The affected product is... | [] | null | null | 9.8 | null |
ICSA-21-040-06 | ICSA-21-040-06_Siemens JT2Go and Teamcenter Visualization (Update A) | Affected applications lack proper validation of user-supplied data when parsing ASM files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11899) Affected applications lack pr... | [] | null | 7.8 | null | null |
ICSA-18-198-03 | PEPPERL+FUCHS VisuNet RM, VisuNet PC, and Box Thin Client | An authentication vulnerability within CredSSP may allow interception of user credentials resulting in remote code execution.CVE-2018-0886 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV: N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.5 | null |
ICSA-24-023-04 | Westermo Lynx 206-F2G | An attacker with access to the web application that has the vulnerable software could introduce arbitrary JavaScript by injecting a cross-site scripting payload into the "forward.0.domain" parameter. An attacker with access to the web application that has the vulnerable software could introduce arbitrary JavaScript by ... | [] | null | 5.4 | null | null |
ICSA-20-189-02 | Mitsubishi Electric GOT2000 Series | The vulnerability could allow a malicious attacker to crash the device, which could lead to remote code execution.CVE-2020-5595 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The vulnerability could allow a malicio... | [] | null | null | 5.3 | null |
ICSA-23-257-04 | Siemens RUGGEDCOM APE1808 Products | An attacker with local access to the system could potentially disclose information
from protected memory areas via a side-channel attack on the processor cache. Existing CommBuffer checks in SmmEntryPoint will not catch underflow when computing BufferSize. An issue was discovered in IhisiSmm in Insyde InsydeH2O with k... | [] | null | 5.1 | null | null |
ICSMA-24-060-01 | MicroDicom DICOM Viewer | MicroDicom DICOM Viewer versions 2023.3 (Build 9342) and prior are affected by a heap-based buffer overflow vulnerability, which could allow an attacker to execute arbitrary code on affected installations of DICOM Viewer. A user must open a malicious DCM file in order to exploit the vulnerability. MicroDicom DICOM View... | [] | null | 7.8 | null | null |
ICSA-24-226-07 | Rockwell Automation Micro850/870 | A denial-of-service vulnerability exists via the CIP/Modbus port in Micro850/870. If exploited, the CIP/Modbus communication may be disrupted for short duration. | [] | null | 5.3 | null | null |
ICSA-23-073-02 | Autodesk FBX SDK | An out-of-bounds read vulnerability in versions of Autodesk FBX SDK prior to version 2020 could result in code execution or information disclosure through maliciously crafted FBX files. This vulnerability, if exploited alongside other vulnerabilities, could also result in code execution in the context of the current pr... | [] | null | null | 7.8 | null |
ICSA-17-285-05 | Siemens BACnet Field Panels (Update A) | An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain informat... | [] | null | 5.3 | null | null |
ICSMA-20-184-01 | OpenClinic GA (Update B) | An attacker may bypass client-side access controls or use a crafted request to initiate a session with limited functionality, which may allow execution of admin functions such as SQL queries.CVE-2020-14485 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string i... | [] | null | null | 9.4 | null |
ICSA-23-010-01 | Black Box KVM | Black Box KVM Firmware version 3.4.31307 on models ACR1000A-R-R2, ACR1000A-T-R2, ACR1002A-T, ACR1002A-R, and ACR1020A-T is vulnerable to path traversal, which may allow an attacker to steal user credentials and other sensitive information through local file inclusion.CVE-2022-4636 has been assigned to this vulnerabilit... | [] | null | null | 7.5 | null |
ICSA-22-041-01 | Siemens SIMATIC Industrial Products (Update A) | An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. CVE-2021-37185 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the ... | [] | null | 7.5 | null | null |
ICSA-19-045-01 | Pangea Communications Internet FAX ATA | Using a specially crafted URL, an attacker can bypass user authentication to cause the device to reboot, which may be used to cause a continual denial-of-service condition.CVE-2019-6551 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI... | [] | null | null | 7.5 | null |
ICSA-22-102-03 | Inductive Automation Ignition | The affected product may allow an attacker with access to the Ignition web configuration to run arbitrary code.CVE-2022-1264 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:N). | [] | null | null | 6.8 | null |
ICSA-23-353-03 | EFACEC UC 500E | An attacker with network access could perform a man-in-the-middle (MitM) attack and capture sensitive information to gain unauthorized access to the application. An attacker could construct a URL within the application that causes a redirection to an arbitrary external domain and could be leveraged to facilitate phishi... | [] | null | null | 4.1 | null |
ICSMA-20-296-02 | B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus | A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations. CVE-2020-25158 has been assigned to this vulnerability. A CV... | [] | null | null | 6.8 | null |
ICSA-22-088-04 | Modbus Tools Modbus Slave | The affected product is vulnerable to a stack-based buffer overflow in the registration field. This may cause the program to crash when a long character string is used.CVE-2022-1068 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U... | [] | null | null | 5.5 | null |
ICSA-22-167-05 | Siemens EN100 Ethernet Module | Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint. This could allow an attacker to crash the affected application leading to a denial of service condition. | [] | null | 8.6 | null | null |
ICSA-24-086-01 | AutomationDirect C-MORE EA9 HMI | There is a function in AutomationDirect C-MORE EA9 HMI that allows an attacker to send a relative path in the URL without properly sanitizing the content. In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on the stack which leads to a... | [] | null | 6.5 | null | null |
ICSA-21-257-04 | Siemens Simcenter Femap | The femap.exe application lacks proper validation of user-supplied data when parsing modfem files. This could result in an out of bounds read past the end of an allocated buffer.
An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14260) | [] | null | 3.3 | null | null |
ICSA-23-054-01 | PTC ThingWorx Edge | The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code. CVE-2023-0755 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C... | [] | null | null | 9.8 | null |
ICSA-19-246-01 | EZAutomation EZ Touch Editor | An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application.CVE-2019-13518 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-22-109-05 | Elcomplus SmartPTT SCADA Server | An authenticated attacker can inject arbitrary JavaScript into critical parameters.CVE-2021-43932 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An unauthenticated user can request various files from the server w... | [] | null | null | 7.6 | null |
ICSA-22-069-06 | Siemens COMOS | Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12019) Open Design Alliance Drawings SDK before 2021.12 contains a memor... | [] | null | 7.8 | null | null |
ICSA-23-159-02 | Sensormatic Electronics Illustra Pro Gen 4 | Sensormatic Electronics Illustra Pro Gen 4 contains a debug feature that is incorrectly set to enabled on newly manufactured cameras. Under some circumstances, over a long period of sustained attack, this could allow compromise of device credentials. | [] | null | null | 8.3 | null |
ICSA-22-179-01 | ABB e-Design | Incorrect default permissions in the affected product create a denial-of-service condition on the target machine, on which affected product is installed, after a reboot.CVE-2022-28702 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N... | [] | null | null | 7.8 | null |
ICSA-23-131-07 | Sierra Wireless AirVantage | The affected products have a CSRF vulnerability that could allow an attacker to execute code and upload malicious files. CVE-2023-2505 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:N). Files present on firmware image... | [] | null | null | 8.4 | null |
ICSA-21-238-04 | Delta Electronics DOPSoft (Update A) | A stack-based buffer overflow vulnerability may be exploited by processing a specially crafted project file, which may allow an attacker to execute arbitrary code.CVE-2021-33019 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H... | [] | null | null | 7.8 | null |
ICSA-23-005-03 | Hitachi Energy Lumada Asset Performance Management | The affected versions of Lumada APM rely on a version of OpenSSL that contains a buffer overflow vulnerability. A buffer overrun can be triggered in X.509 certificate verification, specifically in name constraint checking. Note that this occurs after certificate chain signature verification and requires either a CA to ... | [] | null | null | 7.5 | null |
ICSA-22-326-05 | Moxa Multiple ARM-Based Computers | The affected devices and versions of Moxa's ARM-based computers have an execution with unnecessary privileges vulnerability, which could allow an attacker with user-level privileges to gain root privileges.CVE-2022-3088 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS v... | [] | null | null | 7.8 | null |
ICSA-24-270-02 | Advantech ADAM 5630 | Cookies of authenticated users remain as active valid cookies when a session is closed. Forging requests with a legitimate cookie, even if the session was terminated, allows an unauthorized attacker to act with the same level of privileges of the legitimate user. Cross-site request forgery (CSRF) is a web security vuln... | [] | null | 6.3 | null | null |
ICSA-23-285-06 | Siemens SICAM PAS/PQS | The affected application is installed with specific files and folders with insecure permissions. This could allow an authenticated local attacker to read and modify configuration data in the context of the application process. The affected application is installed with specific files and folders with insecure permissio... | [] | null | 7.8 | null | null |
ICSA-21-159-11 | Siemens SIMATIC NET CP 443-1 OPC UA | The rate limiting feature in NTP 4.x before 4.2.8p4 and 4.3.x before 4.3.77 allows remote attackers to have unspecified impact via a large number of crafted requests. The datalen parameter in the refclock driver in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to execute arbitrary code or ca... | [] | null | 8.8 | null | null |
ICSA-19-304-04 | Honeywell equIP and Performance Series IP Cameras and Recorders | A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products.CVE-2019-18226 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS... | [] | null | null | 7.5 | null |
ICSA-22-104-07 | Siemens Mendix | Applications built with an affected system publicly expose the internal project structure.
This could allow an unauthenticated remote attacker to read confidential information. CVE-2022-27241 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/P... | [] | null | 5.3 | null | null |
ICSA-19-344-06 | Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B) | An attacker in a man-in-the-middle position could modify network traffic exchanged on Port 102/TCP, due to certain properties in the calculation used for integrity protection. CVE-2019-10929 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR... | [] | null | null | 5.3 | null |
ICSA-23-285-10 | Siemens Tecnomatix Plant Simulation | The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. The affected application contains an out of bounds write past the end of an allocated buffer while ... | [] | null | 7.8 | null | null |
ICSA-18-102-01 | Yokogawa CENTUM and Exaopc | A weakness in access controls may allow a local attacker to exploit the message management function of the system.CVE-2018-8838 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H). | [] | null | null | 6.5 | null |
ICSA-24-011-04 | Horner Automation Cscape | In Horner Automation Cscape versions 9.90 SP10 and prior, local attackers are able to exploit this vulnerability if a users opens a malicious CSP file, which would result in execution of arbitrary code on affected installations of Cscape. | [] | null | null | 7.8 | null |
ICSA-24-228-04 | Siemens SINEC Traffic Analyzer | The affected application mounts the container's root filesystem with read and write privileges. This could allow an attacker to alter the container's filesystem leading to unauthorized modifications and data corruption. The affected application do not properly enforce restriction of excessive authentication attempts. ... | [] | null | 4.2 | null | null |
ICSA-17-208-04 | Rockwell Automation Allen-Bradley Stratix and ArmorStratix | Cisco Systems, Inc. has identified multiple SNMP remote code execution vulnerabilities in Cisco IOS and IOS XE Software affecting version of Allen-Bradley Stratix and ArmorStratix. To exploit these vulnerabilities via SNMP v2c or earlier, attacker must know the SNMP read-only community string for the affected system. T... | [] | null | null | 8.8 | null |
ICSA-21-350-11 | Siemens SIMATIC eaSie PCS 7 Skill Package | When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. The affected file download function is disabled by defaul... | [] | null | 6.5 | null | null |
ICSA-21-278-03 | Moxa MXview Network Management Software | A path traversal vulnerability in the application may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.CVE-2021-38452 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:... | [] | null | null | 10 | null |
ICSA-22-195-09 | Simcenter Femap and Parasolid | The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420). CVE-2022-34465 has been assigned to this vulnerability. A CVSS v3 base score of 7... | [] | null | 7.8 | null | null |
ICSA-19-031-01 | Schneider Electric EVLink Parking | A hard-coded credentials vulnerability exists that could enable an attacker to gain access to the device.CVE-2018-7800 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A code injection vulnerability exists that cou... | [] | null | null | 6.4 | null |
ICSA-22-146-01 | Keysight N6854A Geolocation server and N6841A RF Sensor software | The affected products are vulnerable to directory traversal, which may allow an attacker to obtain arbitrary operating system files.CVE-2022-1661 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The affected produc... | [] | null | null | 9.8 | null |
ICSA-20-175-02 | Honeywell ControlEdge PLC and RTU | The affected device exposes unencrypted passwords on the network.CVE-2020-10628 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N). The affected product exposes a session token on the network.CVE-2020-10624 has been a... | [] | null | null | 5.9 | null |
ICSA-24-228-08 | Siemens COMOS | An issue was discovered in Open Design Alliance Drawings SDK before 2024.12. A corrupted value of number of sectors used by the Fat structure in a crafted DGN file leads to an out-of-bounds write. An attacker can leverage this vulnerability to execute code in the context of the current process. Open Design Alliance Dra... | [] | null | 7.8 | null | null |
ICSA-24-074-07 | Siemens SIMATIC | An attacker could cause a crash or potentially execute arbitrary code by sending specially crafted DNS responses to the DNSmasq process. In order to exploit this vulnerability, an attacker must be able to trigger DNS requests from the device, and must be in a privileged position to inject malicious DNS responses. An is... | [] | null | 5.5 | null | null |
ICSA-20-049-02 | Emerson OpenEnterprise | A specially crafted script could execute code on the OpenEnterprise Server.CVE-2020-6970 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.1 | null |
ICSA-18-198-01 | ABB Panel Builder 800 | An improper input validation vulnerability has been identified, which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.CVE-2018-10616 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N... | [] | null | null | 7 | null |
ICSA-18-191-01 | Universal Robots Robot Controllers | The application utilizes hard-coded credentials that may allow an attacker to reset passwords for the controller.CVE-2018-10633 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). Ports 30001/TCP to 30003/TCP listen f... | [] | null | null | 9.8 | null |
ICSA-18-198-01 | ABB Panel Builder 800 | An improper input validation vulnerability has been identified, which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.CVE-2018-10616 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N... | [] | null | null | 7 | null |
ICSA-23-164-01 | Datalogics Library Third-Party | The affected product has a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process. | [] | null | null | 5.5 | null |
ICSA-21-315-12 | Siemens NX JT Translator | The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.
An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565). The affected application is vulnerable to an out of bounds read past the en... | [] | null | 3.3 | null | null |
ICSA-20-324-03 | Real Time Automation EtherNet/IP | The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.CVE-2020-25159 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector ... | [] | null | null | 9.8 | null |
ICSA-17-227-01 | Advantech WebOP | A maliciously crafted project file may be able to trigger a heap-based buffer overflow, which may crash the process and allow an attacker to execute arbitrary code.CVE-2017-12705 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/... | [] | null | null | 4.8 | null |
ICSA-23-194-01 | Siemens RUGGEDCOM ROX | A user can tell curl >= 7.20.0 and <= 7.78.0 to require a successful upgrade to TLS when speaking to an IMAP, POP3 or FTP server (`--ssl-reqd` on the command line or`CURLOPT_USE_SSL` set to `CURLUSESSL_CONTROL` or `CURLUSESSL_ALL` withlibcurl). This requirement could be bypassed if the server would return a properly cr... | [] | null | 9.1 | null | null |
ICSA-23-199-01 | Rockwell Automation Kinetix 5700 DC Bus Power Supply | The Kinetix 5700 DC Bus Power Supply Series A is vulnerable to CIP fuzzing. The new ENIP connections cannot be established if impacted by this vulnerability, which prohibits operational capabilities of the device resulting in a denial-of-service attack. | [] | null | null | 7.5 | null |
ICSA-22-298-07 | Delta Electronics InfraSuite Device Master | Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. CVE-2022-41778 has been assigned... | [] | null | null | 7.5 | null |
ICSA-23-199-07 | WellinTech KingHistorian | An information disclosure vulnerability exists in the User authentication functionality of WellinTech KingHistorian 35.01.00.05. A specially crafted network packet can lead to a disclosure of sensitive information. An attacker can sniff network traffic to leverage this vulnerability. An integer conversion vulnerability... | [] | null | null | 8.1 | null |
ICSA-19-010-03 | Pilz PNOZmulti Configurator | An authenticated attacker with local access to the system containing the PNOZmulti Configurator software can view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can m... | [] | null | null | 3.3 | null |