id stringlengths 12 16 | title stringlengths 6 140 | description stringlengths 76 139k | cpes listlengths 0 0 | cvss_v4_0 null | cvss_v3_1 float64 2.5 10 ⌀ | cvss_v3_0 float64 1.9 10 ⌀ | cvss_v2_0 null |
|---|---|---|---|---|---|---|---|
ICSA-20-119-01 | LCDS LAquis SCADA | The affected product is vulnerable to sensitive information exposure by unauthorized users.CVE-2020-10618 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N). The affected product is vulnerable to arbitrary file creati... | [] | null | null | 6.5 | null |
ICSA-21-112-02 | Mitsubishi Electric GOT (Update A) | A password authentication bypass vulnerability exists in the VNC function of the GOT2000 series and the GOT SIMPLE series due to improper authentication.CVE-2021-20590 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N... | [] | null | null | 5.9 | null |
ICSA-23-236-06 | Rockwell Automation Select Distributed I/O Communication Modules | Pyramid Solutions' affected products, the Developer and DLL kits for EtherNet/IP Adapter and EtherNet/IP Scanner may be vulnerable to an out-of-bounds write, which may allow an unauthorized threat actor to send a specially crafted packet that may result in a denial-of-service condition. | [] | null | null | 8.6 | null |
ICSA-22-221-02 | Emerson ControlWave | Emerson ControlWave firmware images are not signed and only rely on insecure checksums for regular integrity checks. This could allow an attacker to push malicious firmware, remote code execution, or a denial-of-service condition.CVE-2022-30262 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has be... | [] | null | null | 9.1 | null |
ICSA-24-023-03 | Voltronic Power ViewPower Pro | The affected product deserializes untrusted data without sufficiently verifying the resulting data will be valid. When a specific service of the affected product receives a certain message from an unauthenticated user, that process may stop. The affected product is vulnerable to an OS command injection, which may allo... | [] | null | null | 9.8 | null |
ICSA-18-347-03 | Geutebrück GmbH E2 Series IP Cameras | The DDNS configuration (in the Network Configuration panel) is vulnerable to an OS system command injection as root. CVE-2018-19007 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 7.2 | null |
ICSA-21-229-03 | xArrow SCADA | The affected product is vulnerable to cross-site scripting due to parameter -edate ' of the resource xhisalarm.htm, which may allow an unauthorized attacker to execute arbitrary code.CVE-2021-33021 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/... | [] | null | null | 5.6 | null |
ICSA-19-213-01 | Advantech WebAccess HMI Designer | Processing specially crafted MCR files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, allowing remote code execution.CVE-2019-10961 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/A... | [] | null | null | 7.8 | null |
ICSA-19-192-01 | Delta Industrial Automation CNCSoft ScreenEditor | Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap.CVE-2019-10982 has been assigned to this vulnerabilit... | [] | null | null | 3.3 | null |
ICSA-20-308-03 | ARC Informatique PcVue (Update A) | The affected product is vulnerable due to the deserialization of untrusted data, which may allow an attacker to remotely execute arbitrary code on the web and mobile back-end server.CVE-2020-26867 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/A... | [] | null | null | 7.5 | null |
ICSA-22-088-01 | Rockwell Automation ISaGRAF | When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality. CVE-2022-... | [] | null | null | 5.5 | null |
ICSA-22-235-05 | Measuresoft ScadaPro Server | The affected product uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file. CVE-2022-2892 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-18-088-01 | WAGO 750 Series | A remote attack may take advantage of an improper implementation of the 3 way handshake during a TCP connection affecting the communications with commission and service tools. Specially crafted packets may also be sent to Port 2455/TCP/IP, used in Codesys management software, which may result in a denial-of-service con... | [] | null | null | 5.3 | null |
ICSA-21-005-03 | GE Reason RT43X Clocks | A code injection vulnerability exists in one of the webpages that could allow an authenticated remote attacker to execute arbitrary code on the system.CVE-2020-25197 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).... | [] | null | null | 5.3 | null |
ICSA-22-335-01 | Mitsubishi Electric MELSEC iQ-R Series | MELSEC iQ-R Series RJ71EN71 products with firmware versions prior to 65 and R04/08/16/32/120ENCPU products with Network firmware versions prior to 65 are vulnerable to improper input validation. A remote unauthenticated user could cause a denial-of-service condition on a target product by sending specially crafted pack... | [] | null | null | 8.6 | null |
ICSA-17-257-01 | LOYTEC LVIS-3ME | The web user interface fails to prevent access to critical files that non administrative users should not have access to, which could allow an attacker to create or modify files or execute arbitrary code.CVE-2017-13996 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been assigned; the CVSS vect... | [] | null | null | 7.5 | null |
ICSA-24-226-01 | AVEVA SuiteLink Server | If exploited, this vulnerability could cause a SuiteLink server to consume excessive system resources and slow down processing of Data I/O for the duration of the attack. | [] | null | 7.5 | null | null |
ICSA-23-131-02 | Siemens SCALANCE W1750D | The IEEE 802.11 specifications through 802.11ax allow physically proximate attackers to intercept (possibly cleartext) target-destined frames by spoofing a target's MAC address, sending Power Save frames to the access point, and then sending other frames to the access point (such as authentication frames or re-associat... | [] | null | 8.4 | null | null |
ICSA-19-192-02 | Siemens SIMATIC WinCC and PCS7 (Update C) | The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerabili... | [] | null | null | 7.2 | null |
ICSA-23-215-01 | Mitsubishi Electric GOT2000 and GOT SIMPLE | A denial-of-service and spoofing (session hijacking of data connections) vulnerability exists in the FTP server function on GOT2000 series and GOT SIMPLE series because the port number of a data connection can be easily guessed due to predictable exact value from previous values. | [] | null | null | 5.9 | null |
ICSA-20-091-01 | Hirschmann Automation and Control HiOS and HiSecOS Products | The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer.CVE-2020-6994 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N... | [] | null | null | 9.8 | null |
ICSA-20-063-04 | Moxa AWK-3131A Series Industrial AP/Bridge/Client | A specially crafted menu selection string can cause an escape from the restricted console, resulting in system access as the root user. An attacker needs to be authenticated as a low-privilege user to trigger this vulnerability.CVE-2019-5136 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been ... | [] | null | null | 8 | null |
ICSA-23-180-04 | Mitsubishi Electric MELSEC-F Series | An authentication bypass vulnerability due to authentication bypass by capture-replay exists in the MELSEC-F series main modules. | [] | null | null | 7.5 | null |
ICSMA-22-062-02 | BD Viper LT | The affected product is vulnerable due to the use of hard-coded credentials, which may allow a threat actor to access, modify, or delete sensitive information including electronic protected health information (ePHI), protected health information (PHI), and personally identifiable information (PII).CVE-2022-22765 has be... | [] | null | null | 8 | null |
ICSA-21-257-18 | Siemens Siveillance OIS | The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection.
An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges. | [] | null | 10 | null | null |
ICSA-22-242-06 | Honeywell ControlEdge | The affected product root credentials are hard-coded and not changed automatically when first commissioned, which may allow an attacker with SSH access to the device to gain full control.CVE-2022-30318 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:... | [] | null | null | 9.8 | null |
ICSA-23-054-01 | PTC ThingWorx Edge | The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code. CVE-2023-0755 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C... | [] | null | null | 9.8 | null |
ICSA-19-290-01 | AVEVA Vijeo Citect and Citect SCADA (Update A) | The IEC870IP driver for AVEVA 's Vijeo Citect, Citect SCADA, and Schneider Electric 's Power SCADA Operation has a buffer overflow that could result in a server-side crash. This vulnerability impacts only the IEC870IP driver and not the core Vijeo Citect, Citect SCADA, or Power SCADA Operation software.CVE-2019-13537 h... | [] | null | null | 7.5 | null |
ICSA-19-253-02 | Siemens SINETPLAN | The integrated configuration web application allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulne... | [] | null | null | 8 | null |
ICSA-21-112-01 | Horner Automation Cscape | The affected application lacks proper validation of user-supplied data when parsing project files. This could lead to memory corruption. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-22678 has been assigned to this vulnerability. A CVSS v3 base score of 7.8... | [] | null | null | 8.4 | null |
ICSA-21-336-01 | Schneider Electric SESU | An insufficient entropy vulnerability exists, which could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry.CVE-2021-22799 has been assigned to this vulnerability. A CVSS v3 base score of 3.8 has been calculated; the... | [] | null | null | 3.8 | null |
ICSA-24-228-03 | Siemens Teamcenter Visualization and JT2Go | The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. The affected applications contain an out of bounds read past the end of an allocated structure while pars... | [] | null | 3.3 | null | null |
ICSA-21-350-14 | Siemens Siveillance Identity | Affected applications insufficiently limit the access to the internal message broker system.
This could allow an unauthenticated remote attacker to subscribe to arbitrary message queues. Affected applications insufficiently limit the access to the internal activity feed database.
This could allow an unauthenticated r... | [] | null | 7.5 | null | null |
ICSA-23-299-08 | Sielco Radio Link and Analog FM Transmitters | The cookie session ID is of insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session, bypass authentication, and manipulate the transmitter. The application interface allows users to perform certain actions via HTTP requests without performing any validity che... | [] | null | 6.5 | null | null |
ICSA-22-069-12 | Siemens RUGGEDCOM ROS | Improper neutralization of special characters on the web server configuration page could allow an attacker, in a privileged position, to retrieve sensitive information via cross-site scripting. A timing attack, in a third-party component, could make the retrieval of the private key possible, used for encryption of sens... | [] | null | 7.5 | null | null |
ICSMA-22-095-01 | LifePoint Informatics Patient Portal | Navigating to a specific URL with a patient ID number will result in the server generating a PDF of a lab report without authentication and rate limiting.CVE-2022-1067 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N... | [] | null | null | 6.5 | null |
ICSA-20-315-01 | ICSA-20-315-01_OSIsoft PI Interface for OPC XML-DA | The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.CVE-2013-0006 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.1 | null |
ICSA-21-068-08 | Siemens Energy PLUSCONTROL 1st Gen | Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones. | [] | null | 6.5 | null | null |
ICSA-22-242-05 | Fuji Electric D300win | The affected product is vulnerable to an out-of-bounds read, which could allow an attacker to leak sensitive data from the process memory.CVE-2022-1738 has been assigned to this vulnerability. A CVSS v3 base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N). The affected ... | [] | null | null | 6.1 | null |
ICSA-19-344-03 | Siemens RUGGEDCOM ROS (Update A) | The embedded DENX U-Boot boot loader has a locally exploitable buffer overflow via a crafted kernel image because filesystem loading is mishandled.
The security vulnerability could be exploited by an attacker with local access to the affected systems. The vulnerability could allow an attacker to compromise confidentia... | [] | null | 4.6 | null | null |
ICSA-22-333-01 | Mitsubishi Electric GOT2000 | The affected GOT2000 Series devices with FTP server versions 01.39.000 and prior are vulnerable to improper input validation, which could allow an attacker to cause a denial-of-service condition by sending a specially crafted command.CVE-2022-40266 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 ha... | [] | null | null | 5.3 | null |
ICSA-21-063-02 | ICSA-21-063-02_Schneider Electric EcoStruxure Building Operation (EBO) | An unrestricted upload of a file with dangerous type vulnerability could allow an authenticated remote user to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution.CVE-2020-7569 has been assigned to this vulnerability. A CVSS v3 base score of 4.6 has been calcula... | [] | null | null | 4.3 | null |
ICSA-20-315-04 | Siemens SIMATIC S7-300 CPUs and SINUMERIK Controller (Update A) | Sending multiple specially crafted packets to the affected devices could cause a
Denial-of-Service on port 102. A cold restart is required to recover the service.
| [] | null | 5.9 | null | null |
ICSA-19-255-03 | 3S-Smart Software Solutions GmbH CODESYS Control V3 Online User Management | The online user management may incorrectly grant access to sub objects, even if the logged-in user does not have inherited permission to access them. CVE-2019-9008 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.8 | null |
ICSA-22-298-02 | HEIDENHAIN Controller TNC on HARTFORD Machine | The HEIDENHAIN Controller TNC 640, version 340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine is vulnerable to improper authentication, which may allow an attacker to deny service to the production line, steal sensitive data from the production line, and alter any products created by the pr... | [] | null | null | 8.1 | null |
ICSA-21-096-01 | Hitachi Energy Relion 670, 650 and SAM600-IO | An attacker with access to the IEC 61850 network and knowledge of how to reproduce the attack�as well as the IP addresses of the different IEC 61850 access points (of IEDs/products)�can force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only product... | [] | null | null | 7.5 | null |
ICSA-17-355-01 | ICSA-17-355-01_Moxa NPort W2150A and W2250A | The default password is empty on the device. An unauthorized user can access the device without a password. An unauthorized user has the ability to completely compromise the confidentiality and integrity of the wireless traffic.CVE-2017-16727 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been... | [] | null | null | 6.5 | null |
ICSA-22-165-02 | Meridian Cooperative Meridian | Private user information such as name, address, and daily energy usage can be accessed online without proper authentication.CVE-2022-29578 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 7.5 | null |
ICSA-23-166-08 | Siemens SIMATIC STEP 7 and Derived Products | The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.
An attacker with network access to the server network could leverage these embedded functions to run cod... | [] | null | 9.9 | null | null |
ICSA-23-285-13 | Mitsubishi Electric MELSEC-F Series | Information disclosure, information tampering and authentication bypass vulnerability due to improper authentication exists in the MELSEC-F Series main modules. | [] | null | null | 9.1 | null |
ICSA-24-268-06 | OMNTEC Proteus Tank Monitoring | The affected product may allow an attacker to perform administrative actions without without proper authentication. | [] | null | 9.8 | null | null |
ICSA-20-056-04 | Moxa EDS-G516E and EDS-510E Series Ethernet Switches | The attacker may execute arbitrary codes or target the device, causing it to go out of service.CVE-2020-7007 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected products use a weak cryptographic algorithm... | [] | null | null | 9.8 | null |
ICSA-19-036-01 | AVEVA InduSoft Web Studio and InTouch Edge HMI | An unauthenticated remote user could use a specially crafted database connection configuration file to execute an arbitrary process on the server machine. CVE-2019-6545has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H... | [] | null | null | 9.8 | null |
ICSMA-23-103-01 | B. Braun Battery Pack SP with Wi-Fi | An improper neutralization of directives in dynamically evaluated code vulnerability in the Wi-Fi Battery embedded web server versions L90/U70 and L92/U92 can be used to gain administrative access to the Wi-Fi communication module. An authenticated user, having access to both the medical device Wi-Fi network (such as a... | [] | null | null | 5.5 | null |
ICSA-23-131-11 | BirdDog Cameras & Encoders | The affected products have a CSRF vulnerability that could allow an attacker to execute code and upload malicious files. CVE-2023-2505 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:N). Files present on firmware image... | [] | null | null | 8.4 | null |
ICSA-22-228-05 | B&R Industrial Automation Automation Studio 4 | If the PLC has not been sufficiently secured, an attacker could manipulate stored project information. Alternatively, a remote attacker may use spoofing techniques to connect B&R Automation Studio to an attacker-controlled device with manipulated project files. When using project upload in B&R Automation Studio, such c... | [] | null | null | 8.3 | null |
ICSA-19-344-05 | Siemens XHQ Operations Intelligence | The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger acti... | [] | null | 8.8 | null | null |
ICSMA-19-022-01 | Dräger Infinity Delta | A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient monitoring by causing the monitor to repeatedly reboot until it falls back to default configuration and loses network connectivity.CVE-2018-19010 has been assigned t... | [] | null | null | 8.4 | null |
ICSMA-19-113-01 | Fujifilm FCR Capsula X/Carbon X | The device is susceptible to a denial-of-service condition as a result of an overflow of TCP packets, which requires the device to be manually rebooted.CVE-2019-10948 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)... | [] | null | null | 9.8 | null |
ICSA-20-098-03 | HMS Networks eWON Flexy and Cosy | A non-persistent XSS (cross-site scripting) vulnerability exists. An attacker could send a specially crafted URL to initiate a password change for the device. The target must introduce the credentials to the gateway before the attack can be successful.CVE-2020-10633 has been assigned to this vulnerability. A CVSS v3 ba... | [] | null | null | 6.1 | null |
ICSA-21-131-15 | Siemens SIMATIC S7-1500 | Improper buffer restrictions in BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. Improper initialization in subsystem for Intel(R) CSME versions before 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25, Intel(R) TXE versions before 4.0.... | [] | null | 7.8 | null | null |
ICSA-20-042-09 | Siemens OZW Web Server | Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application's export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior a... | [] | null | 5.3 | null | null |
ICSA-20-273-02 | Yokogawa WideField3 | A buffer overflow could be caused when a user loads a maliciously crafted project file.CVE-2020-16232 has been assigned to this vulnerability. A CVSS v3 base score of 2.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:L). | [] | null | null | 2.8 | null |
ICSA-18-324-01 | Teledyne DALSA Sherlock | A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.CVE-2018-17930 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.3 | null |
ICSA-18-067-02 | ICSA-18-067-02_Siemens SIPROTEC 4, SIPROTEC Compact, and Reyrolle Devices using the EN100 Ethernet Communication Module Extension (Update B) | Successful exploitation of this vulnerability could allow an attacker to either upgrade or downgrade the firmware of the device, including downgrading to older versions with known vulnerabilities.CVE-2018-4838 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector stri... | [] | null | null | 7.5 | null |
ICSA-19-043-05 | Siemens Intel Active Management Technology of SIMATIC IPCs | Bleichenbacher-style side channel vulnerability in TLS implementation in Intel Active Management Technology before 12.0.5 may allow an unauthenticated user to potentially obtain the TLS session key via the network. The security vulnerability could be exploited by an attacker with network access to the affected systems.... | [] | null | 5.3 | null | null |
ICSMA-22-095-01 | LifePoint Informatics Patient Portal | Navigating to a specific URL with a patient ID number will result in the server generating a PDF of a lab report without authentication and rate limiting.CVE-2022-1067 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N... | [] | null | null | 6.5 | null |
ICSA-22-349-21 | Siemens SCALANCE X-200RNA Switch Devices | OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack. sshd in OpenSSH 3.6.1p2 and earlier, when PermitRootLogin is disabled and using PAM keyboard-interactive ... | [] | null | 7.8 | null | null |
ICSMA-20-170-01 | Baxter ExactaMix (Update A) | Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, ... | [] | null | null | 8.1 | null |
ICSA-24-270-04 | goTenna Pro X and Pro X2 | The goTenna Pro series uses a weak password for the QR broadcast message. If the QR broadcast message is captured over RF it is possible to decrypt it and use it to decrypt all future and past messages sent via encrypted broadcast. In the goTenna Pro application, the encryption keys are stored along with a static IV on... | [] | null | 9.6 | null | null |
ICSA-24-228-04 | Siemens SINEC Traffic Analyzer | The affected application mounts the container's root filesystem with read and write privileges. This could allow an attacker to alter the container's filesystem leading to unauthorized modifications and data corruption. The affected application do not properly enforce restriction of excessive authentication attempts. ... | [] | null | 4.2 | null | null |
ICSA-22-349-01 | Prosys OPC UA Simulation Server (Update A) | Prosys OPC UA Simulation server v5.03-64 does not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data. CVE-2022-2967 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/U... | [] | null | null | 6.5 | null |
ICSA-22-354-01 | Fuji Electric Tellus Lite V-Simulator | Fuji Electric Tellus Lite V-Simulator versions 4.0.12.0 and prior are vulnerable to an out-of-bounds write which may allow an attacker to execute arbitrary code.CVE-2022-3087 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/... | [] | null | null | 7.8 | null |
ICSA-20-177-03 | Rockwell Automation FactoryTalk View SE | Due to usernames/passwords being stored in plaintext in Random Access Memory (RAM), a local, authenticated attacker could gain access to certain credentials, including Windows Logon credentials.CVE-2020-14480 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string ... | [] | null | null | 8.8 | null |
ICSA-18-310-02 | Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules | An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of commun... | [] | null | null | 8.6 | null |
ICSMA-21-355-01 | Fresenius Kabi Agilia Connect Infusion System (Update A) | Requests may be used to interrupt the normal operation of the device. When exploited, Agilia Link+ must be rebooted via a hard reset triggered by pressing a button on the rack system.CVE-2021-23236 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/... | [] | null | null | 7.5 | null |
ICSA-21-257-21 | Siemens Industrial Edge | An unauthenticated attacker could change the password of any user in the system under certain circumstances and impersonate any valid user on an affected system.CVE-2021-37184 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I... | [] | null | null | 9.8 | null |
ICSA-19-094-04 | Rockwell Automation Stratix 5950 | Sending malformed IPsec packets to an affected device could allow an unauthenticated remote attacker to cause the device to reload. IPsec is disabled by default in the Allen-Bradley Stratix 5950 devices.CVE-2018-0472 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been assigned; the CVSS vector... | [] | null | null | 8.6 | null |
ICSA-23-220-01 | Schneider Electric IGSS | A deserialization of untrusted data vulnerability that could cause an interpretation of malicious payload data exists in the Dashboard module, which could lead to arbitrary code execution if an attacker gets the user to open a malicious file. A missing authentication for critical function vulnerability that could allow... | [] | null | null | 7.8 | null |
ICSA-21-040-07 | Siemens SCALANCE W780 and W740 | Sending specially crafted packets through the ARP protocol to an affected device could cause a partial denial-of-service, preventing the device to operate normally for a short period of time. | [] | null | 4.3 | null | null |
ICSA-22-242-02 | Hitachi Energy Gateway Station (GWS) Product | Hitachi Energy is aware of publicly disclosed reports of multiple vulnerabilities in open-source software components (OpenSSL and Node.JS) used in the Gateway Station (GWS) product. Versions are available to remediate the identified vulnerabilities.CVE-2020-1968, CVE-2020-8172, CVE-2020-8174, CVE-2020-8201, CVE-2020-82... | [] | null | null | 8.1 | null |
ICSA-20-343-10 | Siemens LOGO! 8 BM | A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port. The implemented encryption for comm... | [] | null | 5.9 | null | null |
ICSA-23-131-01 | Siemens Solid Edge | STEPTools v18SP1 ifcmesh library (v18.1) is affected due to a null pointer dereference, which could allow an attacker to deny application usage when reading a specially constructed file, resulting in an application crash. (ZDI-CAN-19429) Affected applications contain an out of bounds read past the end of an allocated b... | [] | null | 7.8 | null | null |
ICSA-22-067-02 | AVEVA System Platform | The affected product stores sensitive information in cleartext, which may allow access to an attacker or a low-privileged user.CVE-2022-0835 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L). | [] | null | null | 8.1 | null |
ICSA-18-212-04 | AVEVA InTouch Access Anywhere | jQuery before Version 3.0.0 is vulnerable to cross-site scripting (XSS) attacks when a cross-domain Ajax request is performed without the dataType option, causing text/javascript responses to be executed.CVE-2015-9251 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vec... | [] | null | null | 6.1 | null |
ICSA-23-229-04 | Walchem Intuition 9 | Walchem Intuition 9 firmware versions prior to v4.21 are missing authentication for some of the API routes of the management web server. This could allow an attacker to download and export sensitive data. Walchem Intuition 9 firmware versions prior to v4.21 are vulnerable to improper authentication. Login credentials a... | [] | null | null | 6.5 | null |
ICSA-24-074-13 | Softing edgeConnector | The affected product is vulnerable to an absolute path traversal vulnerability, which may allow an attacker with admin privileges to write to a file or overwrite a file in the filesystem. The affected product is vulnerable to a cleartext transmission of sensitive information vulnerability, which may allow an attacker t... | [] | null | 8 | null | null |
ICSA-23-164-01 | Datalogics Library Third-Party | The affected product has a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process. | [] | null | null | 5.5 | null |
ICSA-19-283-01 | Siemens Industrial Real-Time (IRT) Devices (Update F) | An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. | [] | null | 7.5 | null | null |
ICSA-21-194-11 | Siemens Teamcenter Active Workspace | By sending malformed requests, a remote attacker could leak an application token due to an error not properly handled by the system. A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking user... | [] | null | 5.3 | null | null |
ICSA-22-277-01 | Johnson Controls Metasys ADX Server | The affected product software does not prove or insufficiently validates user identity claims.CVE-2022-21936 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H). | [] | null | null | 8.1 | null |
ICSMA-19-255-01 | Philips IntelliVue WLAN | An attacker can use these credentials to login via ftp and upload a malicious firmware. CVE-2019-13530 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H). The product downloads source code or an executable from a remo... | [] | null | null | 6.4 | null |
ICSA-21-280-03 | Johnson Controls exacqVision | The affected product is vulnerable to an integer overflow vulnerability, which may allow an attacker to cause a denial-of-service condition.CVE-2021-27665 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-21-257-04 | Siemens Simcenter Femap | The femap.exe application lacks proper validation of user-supplied data when parsing modfem files. This could result in an out of bounds read past the end of an allocated buffer.
An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14260) | [] | null | 3.3 | null | null |
ICSA-21-350-07 | Siemens POWER METER SICAM Q100 | The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution. | [] | null | 9.1 | null | null |
ICSA-22-104-03 | Red Lion DA50N | Authorized users may install a maliciously modified package file when updating the device via the web user interface. The user may inadvertently use a package file obtained from an unauthorized source or a file that was compromised between download and deployment.CVE-2022-26516 has been assigned to this vulnerability. ... | [] | null | null | 4.6 | null |
ICSA-21-147-03 | MesaLabs AmegaView | The affected product is vulnerable to a command injection, which may allow an attacker to remotely execute arbitrary code.CVE-2021-27447 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). The affected product 's pas... | [] | null | null | 7.8 | null |
ICSA-18-261-01 | WECON PLC Editor | When processing project files a stack-based overflow vulnerability can be exploited, which may allow an attacker to execute code under the current process.CVE-2018-14792 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A... | [] | null | null | 6.3 | null |
ICSA-23-313-02 | Hitachi Energy eSOMS | The response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local file system structure. The responses for web queries with certain parameters disclose internal path of resources. This information can be used to learn internal str... | [] | null | 5.3 | null | null |
ICSMA-22-088-01 | Philips e-Alert | The software does not perform any authentication for critical system functionality.CVE-2022-0922 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 6.5 | null |