id stringlengths 12 16 | title stringlengths 6 140 | description stringlengths 76 139k | cpes listlengths 0 0 | cvss_v4_0 null | cvss_v3_1 float64 2.5 10 ⌀ | cvss_v3_0 float64 1.9 10 ⌀ | cvss_v2_0 null |
|---|---|---|---|---|---|---|---|
ICSA-23-131-08 | Teltonika Remote Management System and RUT Model Routers | Teltonika’s Remote Management System versions prior to 4.10.0 contain a function that allows users to claim their devices. This function returns information based on whether the serial number of a device has already been claimed, the MAC address of a device has already been claimed, or whether the attempt to claim a de... | [] | null | null | 8.8 | null |
ICSMA-22-174-01 | OFFIS DCMTK | The affected product 's service class provider (SCP) is vulnerable to path traversal, allowing an attacker to write DICOM files into arbitrary directories under controlled names. This could allow remote code execution.CVE-2022-2119 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated... | [] | null | null | 6.5 | null |
ICSA-24-046-02 | Siemens SIDIS Prime | In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man in the middle attackers to reuse encrypted user credentials sent over the network. Server or client applications that call the SSL_check_c... | [] | null | 7.5 | null | null |
ICSA-20-170-02 | Mitsubishi Electric MC Works64, MC Works32 | A specially crafted communication packet sent to the affected MC Works64 Broker64 or MC Works32 Broker32 systems could cause a denial-of-service condition or allow remote code execution.CVE-2020-12011 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV... | [] | null | null | 7.5 | null |
ICSA-20-161-03 | Siemens LOGO! (Update A) | The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 135/tcp. No user interaction is required to exploit this security vulnerabil... | [] | null | 9.4 | null | null |
ICSA-20-287-06 | Siemens SIPORT MP | Vulnerable versions of the device could allow an authenticated attacker to impersonate other users of the system and perform (potentially administrative) actions on behalf of those users if the single sign-on feature ("Allow logon without password") is enabled. | [] | null | 8.8 | null | null |
ICSA-21-257-05 | Siemens Simcenter STAR-CCM+ Viewer | The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure.
An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700) | [] | null | 7.8 | null | null |
ICSA-17-271-01B | Siemens Ruggedcom ROS, SCALANCE (Update B) | After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to writeto the device under certain conditions, potentially allowing users located in the adjacentnetwork of the targeted device to perform unauthorized administrative actions. | [] | null | null | 8.8 | null |
ICSA-20-210-03 | HMS Industrial Networks eCatcher | The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.CVE-2020-14498 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H). | [] | null | null | 9.6 | null |
ICSA-20-126-01 | Fazecast jSerialComm | An uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code. | [] | null | null | 7.8 | null |
ICSA-18-072-04 | OSIsoft PI Web API | Privileges may be escalated, giving attackers access to the PI System via the service account. CVE-2018-7500 has been assigned to this vulnerability. A CVSS v3 base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:N). Cross-site scripting may occur when input is incorrectly... | [] | null | null | 4.7 | null |
ICSA-23-012-04 | Panasonic Sanyo CCTV Network Camera | Panasonic Sanyo CCTV Network Cameras versions 1.02-05 and 2.03-0x are vulnerable to CSRFs that can be exploited to allow an attacker to perform changes with administrator level privileges.-CVE-2022-4621 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV... | [] | null | null | 7.5 | null |
ICSA-22-167-08 | Siemens SICAM GridEdge | The affected software does not apply cross-origin resource sharing (CORS) restrictions for critical operations. In case an attacker tricks a legitimate user into accessing a special resource a malicious request could be executed. The affected software does not require authenticated access for privileged functions. This... | [] | null | 4.9 | null | null |
ICSA-19-192-07 | Schneider Electric Floating License Manager | A denial of service vulnerability related to preemptive item deletion in lmadmin and vendor daemon components allows a remote attacker to send a combination of messages to lmadmin or the vendor daemon, causing the heartbeat between lmadmin and the vendor daemon to stop and the vendor daemon to shut down.CVE-2018-20031 ... | [] | null | null | 7.5 | null |
ICSA-19-309-01 | Omron CX-Supervisor | Omron CX-Supervisor ships with Teamviewer Version 5.0.8703 QS. This version of Teamviewer is vulnerable to three known bugs listed in the following link: https://www.cvedetails.com/vulnerability-list/vendor_id-11100/product_id-19942/Teamviewer-Teamviewer.htmlCVE-2019-11769, CVE-2018-16550, CVE-2018-14333, and CVE-2010-... | [] | null | null | 9.8 | null |
ICSA-23-138-02 | Mitsubishi Electric MELSEC WS Series | In the affected products, the hidden telnet function is enabled by default when shipped from the factory. An authentication bypass vulnerability could allow a remote unauthenticated attacker to log into the affected module by connecting to it via telnet. | [] | null | null | 7.5 | null |
ICSA-22-300-04 | Trihedral VTScada | A specifically malformed HTTP request could cause the affected VTScada to crash. Both local area network (LAN)-only and internet facing systems are affected.CVE-2022-3181 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/... | [] | null | null | 7.5 | null |
ICSA-23-215-02 | Mitsubishi Electric GT and GOT Series Products | Information disclosure vulnerability exists in the Data Transfer Security function on GT Designer3, GOT2000 Series, GOT SIMPLE Series and GT SoftGOT2000. This vulnerability allows an attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords. | [] | null | null | 7.5 | null |
ICSA-20-070-04 | ICSA-20-070-04_Johnson Controls Kantech EntraPass | An issue with an API may allow an attacker to upload and execute malicious code with system-level privileges.CVE-2019-7589 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-19-213-05 | Rockwell Automation Arena Simulation Software (Update B) | A maliciously crafted Arena file opened by an unsuspecting user may result in the application
crashing or the execution of arbitrary code.CVE-2019-13510 has
been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been assigned; the CVSS
vect... | [] | null | null | 7.8 | null |
ICSA-20-016-01 | Schneider Electric Modicon Controllers (Update A) | This vulnerability could cause a denial-of-service condition in the controller when reading specific memory blocks using Modbus TCP.CVE-2019-6857 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). This vulnerability co... | [] | null | null | 7.5 | null |
ICSA-24-074-04 | Siemens SINEMA Remote Connect Client | The product places sensitive information into files or directories that are accessible to actors who are allowed to have access to the files, but not to the sensitive information. This information is also available via the web interface of the product. | [] | null | 7.6 | null | null |
ICSA-20-070-02 | Siemens SIMATIC S7-300 CPUs and SINUMERIK Controller over Profinet (Update A) | Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time... | [] | null | 7.5 | null | null |
ICSMA-24-200-01 | Philips Vue PACS | A third-party product component writes data past the end, or before the beginning, of the intended buffer. A third-party product component deserializes untrusted data without sufficiently verifying that the resulting data will be valid. A third-party product component deserializes untrusted data without sufficiently ve... | [] | null | 8.2 | null | null |
ICSA-21-133-01 | Rockwell Automation Connected Components Workbench | Connected Components Workbench does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be succes... | [] | null | null | 6.1 | null |
ICSMA-20-233-01 | Philips SureSigns VS4 | The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. | [] | null | null | 2.1 | null |
ICSA-22-228-04 | Softing Secure Integration Server | A crafted HTTP packet with a large content-length header can create a denial-of-service condition in Softing Secure Integration Server.CVE-2022-1069 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The application ... | [] | null | null | 7.5 | null |
ICSA-23-320-09 | Siemens COMOS | MPXJ through 8.1.3 allows XXE attacks. This affects the GanttProjectReader and PhoenixReader components. common/InputStreamHelper.java in Packwood MPXJ before 8.3.5 allows directory traversal in the zip stream handler flow, leading to the writing of files to arbitrary locations. Open Design Alliance Drawings SDK before... | [] | null | 9.6 | null | null |
ICSA-21-105-02 | EIPStackGroup OpENer Ethernet/IP | A specifically crafted packet sent by an attacker to the affected devices may cause a denial-of-service condition.CVE-2021-27478 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). A specifically crafted packet sent b... | [] | null | null | 7.5 | null |
ICSA-17-241-01 | AzeoTech DAQFactory | Local, non-administrative users may be able to replace or modify original application files with malicious ones.CVE-2017-12699 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N). An uncontrolled search path element vu... | [] | null | null | 4.2 | null |
ICSA-23-166-02 | Advantech WebAccess/SCADA | All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to using untrusted pointers. The RPC arguments sent by the client can contain raw memory pointers that will be used as is by the server. This can lead to an attacker gaining access to the remote file system and the ability to execute commands and o... | [] | null | null | 9.8 | null |
ICSA-18-226-03 | Siemens Automation License Manager | A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or sp... | [] | null | null | 5.3 | null |
ICSA-23-222-09 | Siemens OpenSSL RSA Decryption in SIMATIC | A timing based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulne... | [] | null | 5.9 | null | null |
ICSA-23-136-03 | Rockwell Automation FactoryTalk Vantagepoint | The affected product is vulnerable to a cross site request forgery attack that may allow an attacker to impersonate a legitimate user. CVE-2023-2444 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H). | [] | null | null | 7.1 | null |
ICSA-23-129-02 | Hitachi Energy MSM | The code that performs password matching when using 'basic' HTTP authentication does not use a constant-time memcmp and has no rate-limiting. An unauthenticated network attacker could brute-force the HTTP basic password byte-by-byte, by recording the webserver's response time until the unauthorized (401) response. CVE-... | [] | null | null | 7.5 | null |
ICSA-21-315-13 | Siemens Siveillance Video DLNA Server | The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application’s web document directory.
An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks. | [] | null | 8.6 | null | null |
ICSA-24-051-02 | ICSNPP - Ethercat Zeek Plugin | Industrial Control Systems Network Protocol Parsers (ICSNPP) - Ethercat Zeek Plugin versions d78dda6 and prior are vulnerable to out-of-bounds write in their primary analyses function for Ethercat communication packets. This could allow an attacker to cause arbitrary code execution. Industrial Control Systems Network P... | [] | null | 8.2 | null | null |
ICSA-24-219-01 | Delta Electronics DIAScreen | A crafted DPA file could force Delta Electronics DIAScreen to overflow a stack-based buffer, which could allow an attacker to execute arbitrary code. | [] | null | 7.8 | null | null |
ICSA-22-132-11 | Siemens SIMATIC CP 44x-1 RNA | The affected devices improperly handles excessive ARP broadcast requests.
This could allow an attacker to create a denial of service condition by performing ARP storming attacks, which can cause the device to reboot. | [] | null | 7.4 | null | null |
ICSA-17-192-01 | Siemens SIMATIC Logon | Specially crafted packets sent to the SIMATIC Logon Remote Access service on Port 16389/TCP could cause a denial-of-service condition. The service restarts automatically.CVE-2017-9938 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S... | [] | null | null | 5.3 | null |
ICSA-23-103-14 | Datakit CrossCAD-WARE | Datakit CrossCadWare_x64.dll contains an out-of-bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. CVE-2023-22295 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been assig... | [] | null | null | 7.8 | null |
ICSA-21-250-02 | Hitachi ABB Power Grids System Data Manager | The application does not encrypt backup files. A local operating system user can modify backup files, which may allow an attacker to overwrite system configuration files and gain privileges.CVE-2021-35526 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is... | [] | null | null | 6.3 | null |
ICSA-22-347-01 | ICONICS and Mitsubishi Electric Products | A crafted PKGX file could force ICONICS Workbench to write an arbitrary file through path traversal.CVE-2022-40264 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N). | [] | null | null | 6.3 | null |
ICSA-19-297-02 | Honeywell IP-AK2 | The integrated web server of the affected devices could allow remote attackers to obtain web configuration data, which can be accessed without authentication over the network.CVE-2019-13525 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:... | [] | null | null | 5.3 | null |
ICSMA-22-244-01 | Contec Health CMS8000 | A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a drive-by attack to load th... | [] | null | null | 5.7 | null |
ICSA-20-182-01 | Delta Industrial Automation DOPSoft (Update A) | Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information and/or crash the application.CVE-2020-10597 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been calculated; the CVSS vector string is (AV:... | [] | null | null | 7.8 | null |
ICSA-23-348-14 | Siemens RUGGEDCOM and SCALANCE M-800/S615 Family | Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. Th... | [] | null | 7.2 | null | null |
ICSA-21-222-08 | ICSA-21-222-08_Siemens Solid Edge | An XML external entity injection vulnerability in the underlying XML parser could cause the affected application to disclose arbitrary files to remote attackers by loading a specially crafted XML file.CVE-2021-37178 has been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been calculated; the CVSS vecto... | [] | null | null | 7.8 | null |
ICSA-19-318-02 | Siemens S7-1200 and S7-200 SMART CPUs (Update B) | There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process. | [] | null | 6.8 | null | null |
ICSA-22-132-12 | Siemens Industrial Products | In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service condition by sending carefully crafted messages that lead to access of a memory location after the end of a buffer. | [] | null | 7.5 | null | null |
ICSA-17-313-01 | AutomationDirect CLICK, C-More, C-More Micro, Do-more Designer, GS Drives, SL-Soft SOLO, DirectSOFT (Update B) | An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run maliciou... | [] | null | null | 6.7 | null |
ICSA-19-262-01 | Tridium Niagara | The QNX procfs service provides access to various process information and assets, which could allow a less privileged process to gain access to a target address space.CVE-2019-8998 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:... | [] | null | null | 4.4 | null |
ICSA-17-243-01 | Siemens OPC UA Protocol Stack Discovery Service (Update E) | By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker. To execute the attack, the attacker must have network access to the affected devices. | [] | null | 8.2 | null | null |
ICSA-22-165-02 | Meridian Cooperative Meridian | Private user information such as name, address, and daily energy usage can be accessed online without proper authentication.CVE-2022-29578 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 7.5 | null |
ICSA-22-342-01 | Advantech iView | Advantech iView versions 5.7.04.6469 and prior are vulnerable to a SQL injection that could disclose sensitive product information to an unauthorized user.CVE-2022-3323 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:... | [] | null | null | 7.5 | null |
ICSA-21-350-06 | Siemens Capital VSTAR | ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004). CVE-2021-31344 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N). The total length of... | [] | null | 7.5 | null | null |
ICSA-21-350-18 | Siemens Teamcenter Active Workspace | The application contains an unsafe unzipping pattern that could lead to a zip path traversal attack. This could allow and attacker to execute a remote shell with admin rights. | [] | null | 6.8 | null | null |
ICSA-21-350-16 | Siemens Healthineers syngo fastView (Update A) | The affected application lacks proper validation of user-supplied data when parsing DICOM files, which could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-40367 has been assigned to th... | [] | null | null | 7.8 | null |
ICSA-19-192-06 | Schneider Electric Interactive Graphical SCADA System | An out-of-bounds vulnerability exists and could be exploited by the application processing a specially crafted project file. Exploitation could cause a software crash when data in the mdb database is manipulated or allow code execution.CVE-2019-6827 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 h... | [] | null | null | 7 | null |
ICSA-22-181-04 | Distributed Data Systems WebHMI | A user with administrative privileges in WebHMI can store a script that could impact other logged in users.CVE-2022-2254 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N). A user with administrative privileges in Web... | [] | null | null | 6.2 | null |
ICSA-19-204-02 | NREL EnergyPlus | The application fails to prevent an exception handler from being overwritten with arbitrary code.CVE-2019-10974 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L). | [] | null | null | 6.1 | null |
ICSA-21-082-01 | Weintek EasyWeb cMT | The Weintek cMT product line is vulnerable to Code Injection, which may allow an unauthenticated remote attacker to execute commands with root privileges on the operation system.CVE-2021-27446 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L... | [] | null | null | 9.4 | null |
ICSA-22-349-17 | Siemens Mendix Email Connector | Affected versions of the module improperly handle access control for some module entities.
This could allow authenticated remote attackers to read and manipulate sensitive information. | [] | null | 8.1 | null | null |
ICSA-23-348-04 | Siemens LOGO! and SIPLUS LOGO! | Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom cert... | [] | null | 7.6 | null | null |
ICSA-19-043-04 | Siemens SIMATIC S7-300 CPU | The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of ... | [] | null | 7.5 | null | null |
ICSA-22-011-01 | Johnson Controls VideoEdge | The affected product is susceptible to a vulnerability scan, which may cause a denial-of-service condition.CVE-2021-36199 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). | [] | null | null | 5.3 | null |
ICSA-24-270-01 | Advantech ADAM-5550 | User credentials are shared with a low level of encryption, consisting of base 64 encoding. Advantech ADAM 5550's web application includes a "logs" page where all the HTTP requests received are displayed to the user. The device doesn't correctly neutralize malicious code when parsing HTTP requests to generate page outp... | [] | null | 8.8 | null | null |
ICSA-21-259-02 | Schneider Electric EcoStruxure and SCADAPack | When a malicious project file is loaded on the engineering workstation software, it deploys a malicious script to execute arbitrary code in unauthorized locations.CVE-2021-22797has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:... | [] | null | null | 7.8 | null |
ICSA-21-350-19 | Siemens SiPass Integrated | Affected applications insufficiently limit the access to the internal message broker system.
This could allow an unauthenticated remote attacker to subscribe to arbitrary message queues. Affected applications insufficiently limit the access to the internal activity feed database.
This could allow an unauthenticated r... | [] | null | 7.5 | null | null |
ICSA-23-320-03 | Siemens Desigo CC product family | A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap.
An unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe). A buffer over-read v... | [] | null | 9 | null | null |
ICSA-18-072-02 | OSIsoft PI Data Archive | Unauthenticated users may modify deserialized data to send custom requests that crash the server. CVE-2018-7529 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). Insecure default configuration may allow escalation o... | [] | null | null | 5.9 | null |
ICSA-19-036-03 | WECON LeviStudioU (Update A) | Several heap-based buffer overflow vulnerabilities have been identified, which may allow arbitrary code execution.CVE-2019-6539 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Multiple stack-based buffer overflow ... | [] | null | null | 7.8 | null |
ICSA-19-008-02 | Schneider Electric IIoT Monitor (Update A) | A path traversal vulnerability exists, which may allow access to files available to SYSTEM user.CVE-2018-7835 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). An unrestricted upload of a file with dangerous type vu... | [] | null | null | 6.2 | null |
ICSA-18-310-01 | gpsd Open Source Project | A stack-based buffer overflow may allow remote attackers to execute arbitrary code on embedded platforms via traffic on Port 2947/TCP or crafted JSON inputs.CVE-2018-17937 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H... | [] | null | null | 8.3 | null |
ICSA-19-148-01 | Emerson Ovation OCR400 Controller | A stack-based buffer overflow vulnerability has been identified in the embedded third-party FTP server. The vulnerability involves improper handling of a long file name from the LIST command to the FTP service, which may cause the service to overwrite buffers, leading to remote code execution and escalation of privileg... | [] | null | null | 6.8 | null |
ICSA-22-286-04 | Siemens SIMATIC S7-1200 and S7-1500 CPU Families | Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication.
This could allow attackers to discover the private key of a CPU product family ... | [] | null | 9.3 | null | null |
ICSA-20-170-03 | ICONICS GENESIS64, GENESIS32 | A specially crafted communication packet sent to the affected GENESIS64 GenBroker64 or GENESIS32 GenBroker32 systems could cause a denial-of-service condition or allow remote code execution.CVE-2020-12011 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is... | [] | null | null | 7.5 | null |
ICSA-23-348-10 | Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1 | expat 2.1.0 and earlier does not properly handle entities expansion unless an application developer uses the XML_SetEntityDeclHandler function, which allows remote attackers to cause a denial of service (resource consumption), send HTTP requests to intranet servers, or read arbitrary files via a crafted XML document, a... | [] | null | 9.8 | null | null |
ICSA-20-317-01 | Mitsubishi Electric MELSEC iQ-R Series | A denial-of-service vulnerability due to uncontrolled resource consumption exists in MELSEC iQ-R series CPU modules. This vulnerability does not affect products when the To Use or Not to Use Web Server parameter of CPU modules is set to Not Use. The default setting is Not Use.CVE-2020-5666 has been assigned to this vul... | [] | null | null | 6.8 | null |
ICSA-19-199-01 | Johnson Controls exacqVision Server | Some services have an unquoted service path. If an authenticated user is able to insert code in the system root path, that code can be executed during the application startup.CVE-2019-7590 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L... | [] | null | null | 6.7 | null |
ICSMA-20-170-02 | Baxter PrismaFlex and PrisMax (Update B) | The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.CVE-2020-12036 has been assigned to this vulnerab... | [] | null | null | 5.4 | null |
ICSA-24-074-08 | Siemens SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family | Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration information from the exported file. Affected ... | [] | null | 2.7 | null | null |
ICSA-23-278-03 | Mitsubishi Electric CC-Link IE TSN Industrial Managed Switch | An attacker could decrypt ciphertext and disclose sensitive information by sending specially crafted packets and performing a Bleichenbacher style attack An attacker could cause a denial-of-service (DoS) condition on the product by leading a legitimate user to import a malicious certificate | [] | null | null | 6.5 | null |
ICSA-24-046-06 | Siemens Unicam FX | The windows installer agent used in affected product contains incorrect use of privileged APIs that trigger the Windows Console Host (conhost.exe) as a child process with SYSTEM privileges. This could be exploited by an attacker to perform a local privilege escalation attack. | [] | null | 7.8 | null | null |
ICSA-21-103-01 | Schneider Electric SoMachine Basic | Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. This vulnerability is triggered when input passed to the xml ... | [] | null | null | 8.6 | null |
ICSA-19-003-03 | Hetronic Nova-M | These devices use fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent stop state.CVE-2018-19023 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been ... | [] | null | null | 7.6 | null |
ICSA-22-132-07 | Siemens SICAM P850 and SICAM P855 | Affected devices do not properly validate parameters of POST requests. This could allow an authenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device. Affected devices do not properly validate parameters of certain GET and POST... | [] | null | 5.3 | null | null |
ICSA-22-104-12 | Siemens SIMATIC S7-400 | Affected devices improperly handle specially crafted packets sent to port 102/tcp.
This could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations. CVE-2021-40368 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vect... | [] | null | 7.5 | null | null |
ICSA-18-095-02 | Moxa MXview | The private key of the web server is able to be read and accessed via an HTTP GET request, which may allow a remote attacker to decrypt encrypted information. CVE-2018-7506 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:... | [] | null | null | 7.5 | null |
ICSMA-20-079-01 | Insulet Omnipod | The affected insulin pump is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to m... | [] | null | null | 7.3 | null |
ICSA-23-250-01 | Dover Fueling Solutions MAGLINK LX Console | The affected product is vulnerable to authentication bypass that could allow an unauthorized attacker to obtain user access by leveraging the MAGLINK LX Web Console. The affected product could allow a guest user to elevate to admin privileges by leveraging the MAGLINK LX Web Console. The affected product is vulnerable ... | [] | null | null | 6.8 | null |
ICSA-23-166-09 | Siemens Solid Edge | Open Design Alliance Drawings SDK (versions before 2024.1) is vulnerable to an out-of-bounds read when reading a DWG file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19432) | [] | null | 7.8 | null | null |
ICSA-21-313-04 | mySCADA myDESIGNER | The affected product fails to properly validate contents of an imported project file, which may make the product vulnerable to a path traversal payload. This vulnerability may allow an attacker to plant files on the file system in arbitrary locations or overwrite existing files, resulting in remote code execution.CVE-2... | [] | null | null | 7.3 | null |
ICSA-19-094-01 | Omron CX-Programmer | When processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2019-6556 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been assigned... | [] | null | null | 6.6 | null |
ICSA-17-234-03 | SpiderControl SCADA Web Server | An attacker may be able to use a simple GET request to perform a directory traversal into system files.CVE-2017-12694 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). | [] | null | null | 5.3 | null |
ICSA-21-012-01 | Schneider Electric EcoStruxure Power Build-Rapsody (Update A) | A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. When a malicious SSD ... | [] | null | null | 7.8 | null |
ICSA-18-107-04 | Rockwell Automation Stratix and ArmorStratix Switches | A vulnerability in the Smart Install feature of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated remote attacker to trigger a reload of an affected device, resulting in a denial of service (DoS) condition, or to execute arbitrary code on an affected device. The vulnerability is due to imprope... | [] | null | null | 8.8 | null |
ICSA-23-234-02 | Trane Thermostats | A command injection vulnerability exists in Trane Technologies XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick. | [] | null | null | 6.8 | null |
ICSA-21-236-02 | Hitachi ABB Power Grids Retail Operations and CSB Products | An attacker who has gained access to an authorized user 's computer could exploit this vulnerability to access database credentials and gain read/edit access to application data.CVE-2021-35529 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been calculated; the CVSS vector string is (AV:N/AC:H/... | [] | null | null | 7.7 | null |
ICSA-23-199-03 | Iagona ScrutisWeb | Iagona ScrutisWeb versions 2.1.37 and prior are vulnerable to a directory traversal vulnerability that could allow an unauthenticated user to directly access any file outside the webroot. Iagona ScrutisWeb versions 2.1.37 and prior are vulnerable to an insecure direct object reference vulnerability that could allow an ... | [] | null | null | 10 | null |