ICSA-22-349-16
Siemens APOGEE and TALON
A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials.
[]
null
8.8
null
null
ICSA-23-073-02
Autodesk FBX SDK
An out-of-bounds read vulnerability in versions of Autodesk FBX SDK prior to version 2020 could result in code execution or information disclosure through maliciously crafted FBX files. This vulnerability, if exploited alongside other vulnerabilities, could also result in code execution in the context of the current pr...
[]
null
null
7.8
null
ICSA-18-130-01
MatrikonOPC Explorer
Successful exploitation of this vulnerability could allow an attacker to transfer unauthorized files from the host system. The attacker must have local access to be able to exploit this vulnerability.CVE-2018-8714 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector ...
[]
null
null
6.7
null
ICSA-23-348-11
Siemens SINUMERIK
Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial of service condition. A restart is needed to restore normal operations.
[]
null
7.5
null
null
ICSA-19-164-02
WAGO Industrial Managed Switches 852-303, 852-1305, and 852-1505
An attacker with access to the hard-coded credentials may gain access to the operating system of the managed switch with root privileges, which may allow manipulation of the operating system of the managed switch.CVE-2019-12550 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the ...
[]
null
null
9.8
null
ICSA-19-192-03
Siemens TIA Administrator (TIA Portal)
The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker...
[]
null
null
8
null
ICSA-22-314-09
Siemens Teamcenter Visualization and JT2Go
The affected application is vulnerable to fixed-length heap-based buffer while parsing specially crafted TIF files. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2022-39136 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated...
[]
null
7.8
null
null
ICSA-21-217-01
HCC Embedded InterNiche TCP/IP stack, NicheLite (Update B)
When parsing DNS domain names, there are no checks on whether a domain name compression pointer is pointing within the bounds of the packet, which may result in an out-of-bounds read.CVE-2020-25767 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/...
[]
null
null
7.5
null
ICSA-23-341-02
Schweitzer Engineering Laboratories SEL-411L
An Improper Restriction of Rendered UI Layers or Frames in the Schweitzer Engineering Laboratories SEL-411L could allow an unauthenticated attacker to perform clickjacking based attacks against an authenticated and authorized user.
[]
null
4.3
null
null
ICSA-23-194-02
Siemens SiPass Integrated
Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow. This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition.
[]
null
7.5
null
null
ICSA-20-196-02
Moxa EDR-G902 and EDR-G903 Series Routers
Malicious operation of the crafted web browser cookie may cause a stack-based buffer overflow in the system web server.CVE-2020-14511 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-23-320-03
Siemens Desigo CC product family
A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap. An unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe). A buffer over-read v...
[]
null
9
null
null
ICSA-22-132-03
Inkscape in Industrial Products
The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to have access to unauthorized information.CVE-2021-42700 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The affected produ...
[]
null
null
7.8
null
ICSA-19-213-03
3S-Smart Software Solutions GmbH CODESYS V3
The CODESYS Gateway does not correctly verify the ownership of a communication channel. CVE-2019-9010 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H). A crafted communication request may cause uncontrolled memory all...
[]
null
null
7.5
null
ICSMA-18-037-02
GE Medical Devices Vulnerability
GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors. GE Healthcare Discovery 530C has a password of #bigguy1 for the (1) acqservice user and (2) wsservice user of the Xeleris System, which has unspecified impact and att...
[]
null
null
9.8
null
ICSA-21-315-10
Siemens SENTRON powermanager
The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
[]
null
7.8
null
null
ICSMA-18-347-01
Medtronic 9790, 2090 CareLink, and 29901 Encore Programmers
The affected products do not encrypt or do not sufficiently encrypt the following sensitive information while at rest: PII. Some combination of personal data that enables the unique identification of an individual. PII is defined as information that can be used to distinguish or trace an individual 's identity, either ...
[]
null
null
4.6
null
ICSA-19-281-01
SMA Solar Technology AG Sunny WebBox
An attacker could send a malicious link to an authenticated operator, which may allow remote attackers to perform actions with the permissions of the user. This device uses IP addresses to maintain communication after a successful login, which would increase the ease of exploitation.CVE-2019-13529 has been assigned to ...
[]
null
null
9.6
null
ICSA-22-195-09
Simcenter Femap and Parasolid
The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420). CVE-2022-34465 has been assigned to this vulnerability. A CVSS v3 base score of 7...
[]
null
7.8
null
null
ICSA-23-234-01
Hitachi Energy AFF66x
In uClibc and uClibc-ng before 1.0.39, incorrect handling of special characters in domain names DNS servers returned via gethostbyname, getaddrinfo, gethostbyaddr, and getnameinfo could lead to output of wrong hostnames (leading to domain hijacking) or injection into applications (leading to remote code execution, XSS,...
[]
null
null
7.5
null
ICSA-22-130-05
AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere
Windows OS can be configured to overlay a language bar on top of any application. When this OS functionality is enabled, the OS language bar UI will be viewable in the browser alongside the InTouch Access Anywhere and Plant SCADA Access Anywhere applications. It is possible to manipulate the Windows OS language bar to ...
[]
null
null
7.4
null
ICSA-20-105-09
Siemens TIM 3V-IE and 4R-IE Family Devices
The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to e...
[]
null
9
null
null
ICSA-22-104-06
Siemens PROFINET Stack Integrated on Interniche Stack
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafte...
[]
null
5.3
null
null
ICSA-23-269-05
Baker Hughes Bently Nevada 3500
Baker Hughes - Bently Nevada 3500 System TDI Firmware version 5.05 has a vulnerability in their password retrieval functionality which could be used by an attacker to access passwords stored on the device. Baker Hughes - Bently Nevada 3500 System TDI Firmware version 5.05 authentication secrets, used with the Connect P...
[]
null
null
5.4
null
ICSA-21-040-03
Siemens SINEMA Server & SINEC NMS
When uploading files to an affected system using a zip container, the system does not correctly check if the relative file path of the extracted files is still within the intended target directory. With this an attacker could create or overwrite arbitrary files on an affected system. This type of vulnerability is also ...
[]
null
8.8
null
null
ICSA-21-257-22
Siemens Teamcenter Active Workspace
A path traversal vulnerability in the application could allow an attacker to bypass certain restrictions such as direct access to other services within the host.
[]
null
4.5
null
null
ICSA-19-029-01
Yokogawa License Manager Service
UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434: Multiple Yokogawa products utilize a service intended to verify the validity of licensed products being utilized. The service running on affected products does not properly restrict the upload of potentially malicious files, which could result in execution of arb...
[]
null
null
8.1
null
ICSA-23-306-06
Schneider Electric SpaceLogic C-Bus Toolkit
Schneider Electric's SpaceLogic C-Bus Toolkit product is vulnerable due to improper privilege management, which could cause remote code execution when the transfer command is used over the network. Schneider Electric's SpaceLogic C-Bus Toolkit product contains a path traversal vulnerability, which could cause tampering...
[]
null
9.8
null
null
ICSA-22-097-01
Pepperl+Fuchs WirelessHART-Gateway
The affected product allows active SSH and telnet services with hard-coded credentials.CVE-2021-34565 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). jQuery 3.0.0-rc.1 is vulnerable to a denial-of-service conditio...
[]
null
null
3.7
null
ICSA-21-287-07
Siemens SCALANCE
The web interface for RAPConsole lacks Anti-CSRF protections in place for state-changing operations. This can potentially be exploited by an attacker to reboot the affected device if the attacker can convince a user to visit a specially-crafted web page. CVE-2019-5318 has been assigned to this vulnerability. A CVSS v3 ...
[]
null
4.9
null
null
ICSA-21-257-06
Siemens SIMATIC CP (Update A)
An attacker with access to the subnet of the affected device could retrieve sensitive information stored in cleartext. CVE-2021-33716 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
[]
null
6.5
null
null
ICSA-21-159-08
Siemens TIM 1531 IRC
During key agreement in a TLS handshake using a DH(E) based ciphersuite a malicious server can send a very large prime value to the client. This will cause the client to spend an unreasonably long period of time generating a key for this prime resulting in a hang until the client has finished. This could be exploited i...
[]
null
7.5
null
null
ICSA-24-011-06
Siemens Teamcenter Visualization and JT2Go
The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process. The affected applications contain a null pointer dereference vulnerability while parsing specially...
[]
null
7.8
null
null
ICSA-23-026-03
Snap One Wattbox WB-300-IP-3
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior could bypass the brute force protection, allowing multiple attempts to force a login.-CVE-2023-24020 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). Snap One...
[]
null
null
6.7
null
ICSA-23-080-04
Siemens RADIUS Client of SIPROTEC 5 Devices
An issue was discovered in Wind River VxWorks 6.9 and 7, that allows a specifically crafted packet sent by a Radius server, may cause Denial of Service during the IP Radius access procedure.
[]
null
7.5
null
null
ICSA-23-194-02
Siemens SiPass Integrated
Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow. This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition.
[]
null
7.5
null
null
ICSA-24-226-10
Rockwell Automation ControlLogix, GuardLogix 5580, CompactLogix, and Compact GuardLogix 5380
A denial-of-service vulnerability exists in the affected products. A malformed PTP management packet can cause a major nonrecoverable fault in the controller.
[]
null
8.6
null
null
ICSA-22-349-06
Siemens SIMATIC WinCC OA Ultralight Client
The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's cre...
[]
null
5.4
null
null
ICSA-20-154-02
ABB System 800xA Base
Low privileged users can read and modify registry settings used to control system functionality.CVE-2020-8474 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-24-226-04
Rockwell Automation Pavilion8
A vulnerability exists in the affected product due to lack of encryption of sensitive information. The vulnerability results in data being sent between the Console and the Dashboard without encryption, which can be seen in the logs of proxy servers, potentially impacting the data's confidentiality.
[]
null
7.4
null
null
ICSA-22-174-05
Elcomplus SmartICS
The software does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters.CVE-2022-2140 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The soft...
[]
null
null
6.8
null
ICSA-22-181-01
Exemys RME1
By using a specific credential string, an attacker with network access to the device 's web interface could circumvent the authentication scheme and perform administrative operations.CVE-2022-2197 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/A...
[]
null
null
9.8
null
ICSA-22-104-17
Siemens Mendix
When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field.
[]
null
3.1
null
null
ICSA-19-190-02
Rockwell Automation PanelView 5510
A remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device 's file system.CVE-2019-10970 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS ve...
[]
null
null
7.5
null
ICSA-24-200-02
Subnet Solutions PowerSYSTEM Center
Subnet PowerSYSTEM Center products are vulnerable to a prototype pollution vulnerability, which may allow an authenticated attacker to elevate permissions.
[]
null
6.5
null
null
ICSA-21-077-01
Johnson Controls Exacq Technologies exacqVision
exacqVision Web Service can expose sensitive information to an actor who is not explicitly authorized to have access to that information.CVE-2021-27656 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).
[]
null
null
5.3
null
ICSA-19-148-01
Emerson Ovation OCR400 Controller
A stack-based buffer overflow vulnerability has been identified in the embedded third-party FTP server. The vulnerability involves improper handling of a long file name from the LIST command to the FTP service, which may cause the service to overwrite buffers, leading to remote code execution and escalation of privileg...
[]
null
null
6.8
null
ICSMA-19-164-01
BD Alaris Gateway Workstation
The web browser user interface on the Alaris Gateway Workstation does not prevent an attacker with knowledge of the IP address of the Alaris Gateway Workstation terminal to gain access to the status and configuration information of the device.CVE-2019-10962 has been assigned to this vulnerability. A CVSS v3 base score ...
[]
null
null
10
null
ICSA-20-343-06
Siemens XHQ Operations Intelligence
The application's web server could expose non-sensitive information about the server's architecture. This could allow an attacker to adapt further attacks to the version in place. The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing t...
[]
null
8.1
null
null
ICSA-18-072-01
Omron CX-Supervisor (Update A)
Parsing malformed project files may cause a stack-based buffer overflow. CVE-2018-7513 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L). Use after free vulnerabilities can be exploited when CX Supervisor parses a sp...
[]
null
null
5.3
null
ICSA-19-213-06
LCDS LAquis SCADA LQS File Parsing
Processing a specially crafted project file may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information.CVE-2019-10994 has been assigned to this vulnerability. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N). A type conf...
[]
null
null
7.8
null
ICSA-19-323-01
Flexera FlexNet Publisher
A vulnerability related to preemptive item deletion in lmgrd and vendor daemon components allows a remote attacker to send a combination of messages to lmgrd or the vendor daemon, causing the heartbeat between lmgrd and the vendor daemon to stop and the vendor daemon to shut down.CVE-2018-20031 has been assigned to thi...
[]
null
null
7.5
null
ICSMA-21-047-01
Hamilton-T1
Hard-Coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device 's configuration interface.CVE-2020-27278 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N). An ...
[]
null
null
2.1
null
ICSA-23-299-04
Rockwell Automation Arena
Version 16.20 of Rockwell Automation's Arena software contains an out-of-bounds read vulnerability when certain malformed files are processed. An attacker with local access could utilize this to potentially leak memory or achieve arbitrary code execution. Version 16.20 of Rockwell Automation's Arena software contains a...
[]
null
null
7.8
null
ICSA-20-161-04
Siemens SIMATIC, SINAMICS, SINEC, SINEMA, SINUMERIK (Update J)
A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
[]
null
8.8
null
null
ICSA-21-068-06
Siemens TCP/IP Stack Vulnerabilities-AMNESIA:33 in SENTRON PAC / 3VA Devices (Update C)
The TCP/IP stack (uIP) in affected devices is vulnerable to out-of-bounds read when calculating the checksum for IP packets. (FSCT-2020-0009) An attacker located in the same network could trigger a Denial-of-Service condition on the device by sending a specially crafted IP packet. The TCP/IP stack (uIP) in affected de...
[]
null
6.5
null
null
ICSA-22-109-02
Automated Logic WebCTRL
WebCtrl Version 6.1 Help index pages are vulnerable to open redirection. If a user visits a maliciously crafted URL, this vulnerability could allow an attacker to redirect a user to a malicious webpage or download a malicious file.CVE-2022-1019 has been assigned to this vulnerability. A CVSS v3 base score of 5.2 has be...
[]
null
null
5.2
null
ICSA-22-349-07
Siemens Simcenter STAR-CCM+
The affected application improperly assigns file permissions to installation folders. This could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges.
[]
null
7.8
null
null
ICSA-22-286-06
Siemens Desigo PXM Devices
There exists an Improper Neutralization of Special Elements used in an OS Command with root privileges during a restore operation due to the missing validation of the names of files included in the input package. By restoring a specifically crafted package, a remote low-privileged attacker can execute arbitrary system ...
[]
null
8.8
null
null
ICSA-21-063-01
Rockwell Automation 1734-AENTR Series B and Series C
The web interface of the 1734-AENTR communication module mishandles authentication for HTTP POST requests. A remote, unauthenticated attacker can send a crafted request that may allow for modification of the configuration settings.CVE-2020-14504 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has b...
[]
null
null
4.7
null
ICSA-21-315-01
WECON PLC Editor
The affected product is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code.CVE-2021-42705 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:...
[]
null
null
7.8
null
ICSA-20-343-07
Siemens SICAM A8000 RTUs
A web server misconfiguration of the affected device can cause insecure ciphers usage by a user´s browser. An attacker in a privileged position could decrypt the communication and compromise confidentiality and integrity of the transmitted information.
[]
null
8.1
null
null
ICSA-22-074-01
ABB OPC Server for AC 800M
The affected products are vulnerable to an authenticated remote user with low privileges who could successfully insert and execute arbitrary code in the node running the AC 800M OPC Server.CVE-2021-22284 has been assigned to this vulnerability. A CVSS v3 base score of 8.4 has been assigned; the CVSS vector string is (A...
[]
null
null
8.4
null
ICSA-22-314-08
Omron NJ/NX-series Machine Automation Controllers
Use of hard-coded credentials vulnerability exists in machine automation controller NJ series models v1.48 and earlier, machine automation controller NX7 series models v1.28 and earlier, machine automation controller NX1 series models v1.48 and earlier, automation software Sysmac Studio models v1.49 and earlier, and pr...
[]
null
null
7.5
null
ICSA-21-166-02
Automation Direct CLICK PLC CPU Modules
The firmware does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active.CVE-2021-32980 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U...
[]
null
null
7.5
null
ICSA-24-086-02
Rockwell Automation PowerFlex 527
A denial-of-service vulnerability exists in the PowerFlex 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it. A denial-of-service vulnerability exists in the PowerFlex 527 due to improper input validation in the device. If exploited, a d...
[]
null
7.5
null
null
ICSA-20-196-08
Siemens LOGO! Web Server
A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacker could send a specially crafted HTTP request to cause a memory corruption, potentially resulting in remote code execution.
[]
null
9.8
null
null
ICSA-18-058-03
Emerson ControlWave Micro Process Automation Controller
A stack-based buffer overflow vulnerability caused by sending crafted packets on Port 20547 could force the PLC to change its state into halt mode. CVE-2018-5452 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-23-115-02
Scada-LTS Third Party Component
Scada-LTS versions 2.7.4 and prior are vulnerable to cross-site scripting. This could allow a remote attacker to craft malicious URLs that may execute arbitrary code in an authenticated user�s browser and print sensitive information. CVE-2015-1179 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has...
[]
null
null
6.5
null
ICSA-17-234-01
Automated Logic Corporation WebCTRL, i-VU, SiteScan
An unquoted search path vulnerability may allow a non-privileged local attacker to change files in the installation directory and execute arbitrary code with elevated privileges.CVE-2017-9644 has been assigned to this vulnerability. A CVSS v3 base score of 4.2 has been assigned; the CVSS vector string is (AV:L/AC:H/PR:...
[]
null
null
8.3
null
ICSA-21-285-03
Schneider Electric IGSS
The affected product is vulnerable to remote code execution, due to missing length check on user supplied data, when a constructed message is received on the network.CVE-2021-22802 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:...
[]
null
null
5.3
null
ICSA-22-130-04
Eaton Intelligent Power Manager
The affected product is vulnerable to a reflected cross-site scripting vulnerability due to insufficient validation of input from certain resources by the IPM software. An attacker would need access to the local subnet and an administrator interaction to compromise the system.CVE-2021-23282 has been assigned to this vu...
[]
null
null
5.2
null
ICSA-20-051-04
Auto-Maskin RP210E, DCU210E, and Marine Observer Pro (Android App)
The embedded web server software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.CVE-2018-5402 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H...
[]
null
null
7.5
null
ICSA-22-165-03
Mitsubishi Electric MELSEC-Q/L and MELSEC iQ-R
The affected product is vulnerable to an improper input validation in various web functions, which could allow an attacker to perform remote code execution or cause a denial-of-service condition.CVE-2022-25163 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string...
[]
null
null
8.1
null
ICSA-23-348-16
Siemens SINEC INS
A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resource...
[]
null
6.8
null
null
ICSA-19-232-01
Zebra Industrial Printers
Zebra printers are shipped with unrestricted end-user access to front panel options. If the option to use a passcode to limit the functionality of the front panel is applied, specially crafted packets could be sent over the same network to a port on the printer and the printer will respond with an array of information ...
[]
null
null
5.3
null
ICSA-24-030-02
Mitsubishi Electric FA Engineering Software Products
A remote unauthenticated attacker may be able to bypass authentication by sending specially crafted packets and connect to the products illegally. An attacker may be able to execute a malicious code by remotely calling a function with a path to a malicious library while connected to the products. As a result, unauthor...
[]
null
9.8
null
null
ICSA-22-347-01
ICONICS and Mitsubishi Electric Products
A crafted PKGX file could force ICONICS Workbench to write an arbitrary file through path traversal.CVE-2022-40264 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N).
[]
null
null
6.3
null
ICSA-19-017-01
Omron CX-Supervisor (Update A)
The application can execute code that has been injected into a project file. An attacker could exploit this to execute code under the privileges of the application.CVE-2018-19011 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/...
[]
null
null
2.8
null
ICSA-20-042-13
Digi ConnectPort LTS 32 MEI
Successful exploitation of this vulnerability could allow an attacker to upload a malicious file to the application. CVE-2020-6975 has been assigned to this vulnerability. A CVSS v3 base score of 2.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N). Multiple cross-site scripting vuln...
[]
null
null
8.5
null
ICSA-18-200-03
Echelon SmartServer 1, SmartServer 2, SmartServer 3, i.LON 100, i.LON 600 (Update A)
An attacker can use the SOAP API to retrieve and change sensitive configuration items such as the usernames and passwords for the Web and FTP servers. This vulnerability does not affect the i.LON 600 product.CVE-2018-10627 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVS...
[]
null
null
9.8
null
ICSA-22-242-05
Fuji Electric D300win
The affected product is vulnerable to an out-of-bounds read, which could allow an attacker to leak sensitive data from the process memory.CVE-2022-1738 has been assigned to this vulnerability. A CVSS v3 base score of 8.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N). The affected ...
[]
null
null
6.1
null
ICSA-23-269-01
Suprema BioStar 2
Suprema BioStar 2 v2.8.16 was discovered to contain a SQL injection vulnerability via value parameters.
[]
null
null
6.5
null
ICSA-17-325-01
PHOENIX CONTACT WLAN Capable Devices using the WPA2 Protocol
Multiple products are affected by key reinstallation attacks known as KRACK. The four-way hand shake traffic in the Wi-Fi Protected Access WPA and WPA2 protocol can be manipulated to allow nonce reuse resulting in key reinstallation. This could allow an attacker to execute a man-in-the-middle attack, enabling the attac...
[]
null
null
6.8
null
ICSA-18-165-01
Siemens SCALANCE X Switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C (Update D)
Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
[]
null
7.5
null
null
ICSA-22-188-02
Bently Nevada ADAPT 3701/4X Series and 60M100
The affected product has credentials for the maintenance interface hardcoded in the firmware. The maintenance interface allows for debug and process execution capabilities, which could allow remote code execution or cause a denial-of-service condition.CVE-2022-29953 has been assigned to this vulnerability. A CVSS v3 ba...
[]
null
null
7.4
null
ICSA-24-268-02
Alisonic Sibylla
Alisonic Sibylla devices are vulnerable to SQL injection attacks, which could allow complete access to the database.
[]
null
9.4
null
null
ICSA-21-133-02
Johnson Controls Sensormatic Tyco AI
Tyco AI calculates, or uses an incorrect maximum or minimum value that is one more or one less than the correct value.CVE-2021-3156 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-18-317-06
Siemens SIMATIC STEP 7 (TIA Portal)
Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the...
[]
null
null
4
null
ICSMA-20-196-01
Capsule Technologies SmartLinx Neuron 2 (Update A)
A restricted environment escape vulnerability exists in the kiosk mode function of Capsule Technologies SmartLinx Neuron 2 medical information collection devices running Version 6.9.1. A specific series of keyboard inputs can allow an escape from the restricted environment, resulting in full administrator access to the...
[]
null
null
7.6
null
ICSA-17-241-02
Advantech WebAccess
By submitting a specially crafted parameter, it is possible to inject arbitrary SQL statements that could allow an attacker to obtain sensitive information.CVE-2017-12710 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/...
[]
null
null
4.8
null
ICSA-22-174-02
Yokogawa CAMS for HIS
If an attacker successfully compromises a computer using CAMS for HIS software, they can use credentials from the compromised machine to access data from another machine using CAMS for HIS software. This can lead to a disabling of CAMS for HIS software functions on any affected machines. CVE-2022-30707 has been assigne...
[]
null
null
6.4
null
ICSA-18-338-02
SpiderControl SCADA WebServer
Reflected cross-site scripting (non-persistent) could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim 's browser. CVE-2018-18991 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string...
[]
null
null
6.1
null
ICSA-23-131-05
Siemens SINEC NMS Third-Party
When doing HTTP(S) transfers, libcurl might erroneously use the read callback (`CURLOPT_READFUNCTION`) to ask for data to send, even when the `CURLOPT_POSTFIELDS` option has been set, if the same handle previously was used to issue a `PUT` request which used that callback. This flaw may surprise the application and cau...
[]
null
7.5
null
null
ICSA-19-260-01
Advantech WebAccess
An exploit executed over the network may cause improper control of generation of code, which may allow remote code execution, data exfiltration, or cause a system crash.CVE-2019-13558 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N...
[]
null
null
9.8
null
ICSA-21-257-14
Siemens SINEC NMS
An attacker with access to the webserver of an affected system could download arbitrary files from the underlying filesystem by sending a specially crafted HTTP request. The web interface of affected devices is vulnerable to a Cross-Site Request Forgery (CSRF) attack. This could allow an attacker to manipulate the SINE...
[]
null
8.8
null
null
ICSA-21-119-04
Multiple RTOS (Update E)
Media Tek LinkIt SDK versions prior to 4.6.1 is vulnerable to integer overflow in memory allocation calls pvPortCalloc(calloc) and pvPortRealloc(realloc), which can lead to memory corruption on the target device.CVE-2021-30636 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the...
[]
null
null
9
null
ICSA-20-135-01
Opto 22 SoftPAC Project
Paths specified within the zip files used to update the SoftPAC firmware are not sanitized. As a result, an attacker with user privileges can gain arbitrary file write access with system access.CVE-2020-12042 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector strin...
[]
null
null
9.8
null
ICSMA-21-308-01
Philips Tasy EMR
The affected product allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter.CVE-2021-39375 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The affected product allows SQL inject...
[]
null
null
8.8
null
ICSA-21-019-02
Reolink P2P Cameras
An attacker with local network access can obtain a fixed cryptography key which may allow for further compromise of Reolink P2P cameras outside of local network access.CVE-2020-25173 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/...
[]
null
null
9.1