ICSA-18-079-02 | Siemens SIMATIC, SINUMERIK, and PROFINET IO (Update D) | Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system.
The security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to... | [] | null | 6.5 | null | null |
ICSA-22-286-05 | Hitachi Energy Lumada Asset Performance Management Prognostic Model Executor Service | A vulnerability exists in the Spring Framework component included in the Prognostic Model Executor service of the affected product. An attacker could exploit this vulnerability by sending a specially crafted data or configuration to the application either directly or via integrated applications, causing the Prognostic ... | [] | null | null | 7.5 | null |
ICSA-21-012-05 | Siemens SCALANCE X Products (Update B) | The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on ... | [] | null | 9.8 | null | null |
ICSA-23-171-01 | Enphase Envoy | Enphase Envoy versions D7.0.88 and prior are vulnerable to a command injection exploit that may allow an attacker to execute root commands. | [] | null | null | 6.3 | null |
ICSA-19-134-04 | Siemens LOGO! 8 BM (Update A) | Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is... | [] | null | 7.5 | null | null |
ICSA-24-011-03 | Rapid Software LLC Rapid SCADA | By utilizing a Zip Slip vulnerability in the unpacking routine, an attacker can supply a malicious configuration file to achieve remote code execution. By appending path traversal characters to the filename when using a specific command, an attacker can read arbitrary files from the system. Due to improper permissions ... | [] | null | 5.3 | null | null |
ICSMA-19-274-01 | Interpeak IPnet TCP/IP Stack (Update D) | This vulnerability resides in the IPv4 option parsing and may be triggered by IPv4 packets containing invalid options.
The most likely outcome of triggering this defect is that the tNet0 task crashes. This vulnerability can result in remote code execution.CVE-2019-12256 has been assigned to this vulnerability. A CVSS v... | [] | null | null | 5.4 | null |
ICSA-22-314-03 | Siemens SINEC Network Management System Logback Component | In logback version 1.2.7 and prior versions, an attacker with the required privileges to edit configurations files could craft a malicious configuration allowing to execute arbitrary code loaded from LDAP servers. | [] | null | 6.6 | null | null |
ICSA-20-098-01 | Advantech WebAccess/NMS | Multiple issues exist that allow files to be uploaded and executed on the system.CVE-2020-10621 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). There are multiple ways an unauthenticated attacker could perform SQL... | [] | null | null | 8.8 | null |
ICSA-20-317-01 | Mitsubishi Electric MELSEC iQ-R Series | A denial-of-service vulnerability due to uncontrolled resource consumption exists in MELSEC iQ-R series CPU modules. This vulnerability does not affect products when the To Use or Not to Use Web Server parameter of CPU modules is set to Not Use. The default setting is Not Use.CVE-2020-5666 has been assigned to this vul... | [] | null | null | 6.8 | null |
ICSA-21-103-03 | JTEKT TOYOPUC products | If Ethernet communication of the affected product is left in an open state by an attacker, Ethernet communications cannot be established with other devices, depending on the settings of the link parameters.CVE-2021-27458 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS ... | [] | null | null | 7.5 | null |
ICSA-23-236-05 | CODESYS Development System | In CODESYS Development System versions from 3.5.11.0 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server. | [] | null | null | 9.6 | null |
ICSA-18-065-03 | Eaton ELCSoft | There are multiple cases where specially crafted files could cause a buffer overflow which, in turn, may allow remote execution of arbitrary code. CVE-2018-7511 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L). | [] | null | null | 6.3 | null |
ICSA-22-055-01 | FATEK Automation FvDesigner | The affected product is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code.CVE-2022-25170 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:... | [] | null | null | 7.8 | null |
ICSA-20-287-03 | Flexera InstallShield | The affected product is subject to an untrusted search path vulnerability, which may allow an attacker to execute a malicious DLL if placed into the working directory of the setup-launcher executable file through social engineering.CVE-2016-2542 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has b... | [] | null | null | 7.3 | null |
ICSA-23-096-03 | JTEKT ELECTRONICS Kostac PLC Programming Software | When a specially crafted project file is opened, out-of-bounds read occurs when processing a comment block in stage information because the end of data cannot be verified. CVE-2023-22419 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:... | [] | null | null | 7.8 | null |
ICSA-18-240-01 | Schneider Electric Modicon M221 | This vulnerability allows unauthorized users to replay authentication sequences.If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker may upload the original program from the PLC.CVE-2018-7790 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the... | [] | null | null | 7.7 | null |
ICSA-21-040-08 | Siemens SIMARIS Configuration (Update A) | During installation to default target folder, incorrect permissions are configured for the application folder and subfolders, which may allow an attacker to gain persistence or potentially escalate privileges if a user with elevated credentials logs onto the machine.CVE-2020-28392 has been assigned to this vulnerabilit... | [] | null | null | 4.4 | null |
ICSA-23-166-03 | Siemens SICAM Q200 Devices | Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session. Affected devices do not proper... | [] | null | 5.5 | null | null |
ICSA-23-166-11 | Siemens SIMATIC S7-1500 TM MFP Linux Kernel | A memory overflow vulnerability was found in the Linux kernel’s ipc functionality of the memcg subsystem, in the way a user calls the semget function multiple times, creating semaphores. This flaw allows a local user to starve the resources, causing a denial of service. The highest threat from this vulnerability is to ... | [] | null | 7.1 | null | null |
ICSA-22-195-08 | Siemens PADS Standard/Plus Viewer | The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-037, FG-VD-22-059) The affected application contains an out of bounds write past the... | [] | null | 3.3 | null | null |
ICSA-18-317-05 | Siemens SIMATIC S7 (Update A) | An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit th... | [] | null | 5.3 | null | null |
ICSA-24-011-07 | Siemens Spectrum Power 7 | The affected product's sudo configuration permits the local administrative account to execute several entries as root user. This could allow an authenticated local attacker to inject arbitrary code and gain root access. | [] | null | 7.8 | null | null |
ICSA-22-284-02 | Daikin Holdings Singapore | This vulnerability allows a remote attacker to obtain user login credentials, login to SVMPC, and fully control the system.CVE-2022-41653 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). This vulnerability allows r... | [] | null | null | 7.5 | null |
ICSA-21-313-02 | Schneider Electric GUIcon | This vulnerability may cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool.CVE-2021-22807 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability may ca... | [] | null | null | 4.4 | null |
ICSA-23-285-09 | Siemens CPCI85 Firmware of SICAM A8000 Devices | The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected. | [] | null | 9.8 | null | null |
ICSA-21-124-02 | Delta Electronics CNCSoft ScreenEditor | An out-of-bounds write vulnerability exists and could cause the corruption of data, a denial-of-service condition, or allow code execution. The vulnerability may allow an attacker to remotely execute arbitrary code.CVE-2021-22672 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; ... | [] | null | null | 7.8 | null |
ICSA-21-287-06 | Siemens Solid Edge | The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process. The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user s... | [] | null | 7.8 | null | null |
ICSA-22-286-10 | Siemens JT Open Toolkit and Simcenter Femap | The JTTK library is vulnerable to an uninitialized pointer reference vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-16973) | [] | null | 7.8 | null | null |
ICSA-23-313-02 | Hitachi Energy eSOMS | The response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local file system structure. The responses for web queries with certain parameters disclose internal path of resources. This information can be used to learn internal str... | [] | null | 5.3 | null | null |
ICSA-20-343-02 | Mitsubishi Electric GOT and Tension Controller (Update B) | There is an out-of-bounds read vulnerability that may allow attackers to cause deterioration in communication performance or cause a denial-of-service condition of the TCP communication functions of the products by sending specially crafted packets.CVE-2020-5675 has been assigned to this vulnerability. A CVSS v3 base s... | [] | null | null | 7.5 | null |
ICSA-17-243-04 | OPW Fuel Management Systems SiteSentinel Integra and SiteSentinel iSite | An attacker may create an application user account to gain administrative privileges.CVE-2017-12733 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The application is vulnerable to injection of malicious SQL queri... | [] | null | null | 8.2 | null |
ICSMA-23-285-02 | Santesoft Sante FFT Imaging | The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. | [] | null | null | 7.8 | null |
ICSA-22-102-04 | Mitsubishi Electric GT25-WLAN | The affected product is vulnerable to a fragment cache attack as it does not clear fragments from memory when (re)connecting. This may allow an attacker to steal communication contents or inject unauthorized packets. CVE-2020-24586 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been assigned; ... | [] | null | null | 5.3 | null |
ICSA-21-315-07 | Siemens Nucleus RTOS-based APOGEE and TALON Products (Update C) | ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004). CVE-2021-31344 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N). The total length of a... | [] | null | 7.5 | null | null |
ICSA-22-069-06 | Siemens COMOS | Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12019) Open Design Alliance Drawings SDK before 2021.12 contains a memor... | [] | null | 7.8 | null | null |
ICSA-20-100-01 | Rockwell Automation RSLinx Classic | An authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.CVE-2020-10642 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C... | [] | null | null | 8.8 | null |
ICSA-18-277-01 | WECON PI Studio (Update A) | When parsing specific files the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code under the context of an administrator.CVE-2018-14818 has been assigned to this vulnerability. A CVSS v... | [] | null | null | 3.3 | null |
ICSA-20-014-06 | OSIsoft PI Vision | The affected product is vulnerable to an improper access control, which may return unauthorized tag data when viewing analysis data reference attributes.CVE-2019-18275 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N... | [] | null | null | 5.1 | null |
ICSA-22-013-02 | Siemens SICAM A8000 | An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device. The web server of the affected system allows access to logfiles and diagnostic data generated by a privile... | [] | null | 5.3 | null | null |
ICSA-22-167-12 | Siemens Spectrum Power Systems | An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges. | [] | null | 8.8 | null | null |
ICSA-22-286-02 | Siemens Industrial Edge Management | All versions of Siemens Industrial Edge Management prior to version 1.5.1 do not properly validate the server certificate when initiating a TLS connection. This could allow an attacker to spoof a trusted entity 's certificate by interfering in the communication path between the client and the intended server.CVE-2022-4... | [] | null | null | 7.4 | null |
ICSA-20-079-01 | Systech NDS-5000 Terminal Server | The affected product is vulnerable to a stored cross-site scripting error, which may allow an attacker to perform privileged operations on behalf of the user, gain access to sensitive data belonging to the user, and remotely execute arbitrary code.CVE-2020-7006 has been assigned to this vulnerability. A CVSS v3 base sc... | [] | null | null | 6.8 | null |
ICSA-22-223-05 | Siemens SICAM A8000 Web Server Module | The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems. | [] | null | 4.3 | null | null |
ICSA-20-105-01 | Eaton HMiSoft VU3 | A specially crafted input file could cause a buffer overflow when loaded by the affected product.CVE-2020-10639 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A specially crafted input file could trigger an out-o... | [] | null | null | 3.3 | null |
ICSA-17-334-02 | GEOVAP Reliance SCADA | This vulnerability could allow an unauthenticated attacker to inject arbitrary code.CVE-2017-16721 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). | [] | null | null | 6.1 | null |
ICSA-18-100-02 | Omron CX-One | Parsing malformed project files may cause a heap-based buffer overflow.CVE-2018-8834 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L). Parsing malformed project files may cause a stack-based buffer overflow.CVE-2018... | [] | null | null | 5.3 | null |
ICSA-23-073-03 | GE iFIX | GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software. CVE-2023-0598 has been assigned to this ... | [] | null | null | 7.8 | null |
ICSA-22-349-12 | Siemens Parasolid | A buffer overrun can be triggered in X.509 certificate verification, specifically in name constraint checking. Note that this occurs after certificate chain signature verification and requires either a CA to have signed the malicious certificate or for the application to continue certificate verification despite failur... | [] | null | 7.5 | null | null |
ICSA-21-103-14 | Siemens Nucleus DNS (Update A) | The DNS client does not properly randomize UDP port numbers of DNS requests. That could allow an attacker to poison the DNS cache or spoof DNS resolving. | [] | null | 5.3 | null | null |
ICSA-22-293-01 | Bentley Systems MicroStation Connect | The affected product is vulnerable to a stack-based buffer overflow when a malformed design (DGN) file is parsed. This may allow an attacker to execute arbitrary code.CVE-2022-40201 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S... | [] | null | null | 7.8 | null |
ICSA-21-341-01 | Hitachi Energy RTU500 OpenLDAP | A vulnerability exists in the affected OpenLDAP versions leading to an LDAP service crash in the parsing of a keystring, resulting in a denial-of-service condition.CVE-2020-36229 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/... | [] | null | null | 7.5 | null |
ICSA-23-080-01 | Keysight N6845A Geolocation Server | N6854A Geolocation Server versions 2.4.2 are vulnerable to untrusted data deserialization, which may allow a malicious actor to escalate privileges in the affected device’s default configuration and achieve remote code execution. CVE-2023-1399 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has bee... | [] | null | null | 7.8 | null |
ICSA-19-162-04 | Siemens SCALANCE X (Update B) | The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords. | [] | null | 7.1 | null | null |
ICSA-17-278-01A | GE CIMPLICITY (Update A) | A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution. CVE-2017-12732 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been assigned; the CVSS vector string is (AV:A/... | [] | null | null | 6.8 | null |
ICSA-22-263-04 | Host Engineering Communications Module | Using custom code, an attacker can write into name or description fields on the affected product larger than the appropriate buffer size causing a stack-based buffer overflow. This may allow an attacker to crash the affected device or cause it to become unresponsive.CVE-2022-3228 has been assigned to this vulnerability... | [] | null | null | 6.5 | null |
ICSA-22-167-14 | Siemens OpenSSL Affected Industrial Products (Update C) | The BN_mod_sqrt() function in openSSL, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base poin... | [] | null | 7.5 | null | null |
ICSA-23-159-02 | Sensormatic Electronics Illustra Pro Gen 4 | Sensormatic Electronics Illustra Pro Gen 4 contains a debug feature that is incorrectly set to enabled on newly manufactured cameras. Under some circumstances, over a long period of sustained attack, this could allow compromise of device credentials. | [] | null | null | 8.3 | null |
ICSA-18-128-03 | Siemens Siveillance VMS Video Mobile App | Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the commu... | [] | null | null | 4.8 | null |
ICSA-21-077-01 | Johnson Controls Exacq Technologies exacqVision | exacqVision Web Service can expose sensitive information to an actor who is not explicitly authorized to have access to that information.CVE-2021-27656 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N). | [] | null | null | 5.3 | null |
ICSA-24-228-07 | Siemens Location Intelligence | The web server of affected products is configured to support weak ciphers by default. This could allow an unauthenticated attacker in an on-path position to to read and modify any data passed over the connection between legitimate clients and the affected device. Affected products do not properly enforce restriction o... | [] | null | 5.3 | null | null |
ICSA-20-184-01 | Nortek Linear eMerge 50P/5000P | The software uses external input to construct a pathname that should be within a restricted directory, but does not properly neutralize sequences such as ../ that can resolve to a location that is outside of that directory. This allows attackers to traverse the file system to access files or directories that are outsid... | [] | null | null | 8.1 | null |
ICSMA-18-240-01 | ICSMA-18-240-01_Qualcomm Life Capsule | This vulnerability allows an attacker to send a specially crafted HTTP cookie to the web management portal to write arbitrary data to the device memory, which may allow remote code execution.CVE-2014-9222 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is... | [] | null | null | 9.8 | null |
ICSA-22-167-01 | AutomationDirect C-More EA9 HMI | The affected product has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process.CVE-2022-2006 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The af... | [] | null | null | 7.5 | null |
ICSA-21-054-01 | Rockwell Automation FactoryTalk Services Platform | There is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly.CVE-2020-14516 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/... | [] | null | null | 10 | null |
ICSA-18-221-01 | Crestron TSW-X60 and MC3 | This vulnerability may allow unauthenticated remote code execution via a Bash shell service in Crestron Toolbox Protocol (CTP). This vulnerability only affects TSW-X60 devices.CVE-2018-11228 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR... | [] | null | null | 8.8 | null |
ICSA-21-194-02 | Schneider Electric Modicon Controllers and Software (Update A) | An insufficiently protected credentials vulnerability exists that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. CVE-2021-22778 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (... | [] | null | null | 6.2 | null |
ICSA-22-088-02 | Omron CX-Position | The affected product is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code.CVE-2022-26419 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:... | [] | null | null | 7.8 | null |
ICSA-22-104-08 | Siemens SCALANCE W1700 | Affected devices do not properly handle resources of ARP requests. This could allow an attacker to cause a race condition that leads to a crash of the entire device. Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition. Affected de... | [] | null | 4.3 | null | null |
ICSA-17-045-03 | Siemens SIMATIC Authentication Bypass (Update D) | An attacker with knowledge of a valid user name, and physical or network access to the affected system could bypass the application-level authentication. | [] | null | null | 9 | null |
ICSA-22-090-01 | Schneider Electric SCADAPack Workbench | An improper restriction of XML external entity reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a remote system controlled by an attacker.CVE-2022-0... | [] | null | null | 5.5 | null |
ICSA-22-314-06 | Siemens QMS Automotive | User credentials are stored in plaintext in the database. This could allow an attacker to gain access to credentials and impersonate other users. | [] | null | 7.6 | null | null |
ICSA-23-192-03 | Panasonic Control FPWin Pro7 | In Panasonic Control FPWIN versions 7.6.0.3 and prior, a stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or a parameter to a function). Panasonic Control FPWIN versions 7.6.0.3 and prior allocates or initializes a resource such... | [] | null | null | 7.8 | null |
ICSA-18-317-08 | Siemens SIMATIC Panels | A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authenitcation is required to exploit the vulnerability. The vulnerability impacts the co... | [] | null | 6.5 | null | null |
ICSA-17-250-02 | PHOENIX CONTACT, Innominate Security Technologies mGuard Firmware | Openswan 2.6.39 and earlier, which is used in the mGuard firmware version 8.0.0 to 8.5.1, allows remote attackers to cause a denial of service (NULL pointer dereference and IKE daemon restart) via IKEv2 packets that lack expected payloads.CVE-2013-6466 has been assigned to this vulnerability. A CVSS v3 base score of 7.... | [] | null | null | 7.5 | null |
ICSA-20-224-07 | Siemens Automation License Manager | The application does not properly validate the users' privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing. | [] | null | 7.3 | null | null |
ICSMA-21-322-01 | Philips IntelliBridge EC 40 and EC 80 Hub | The software contains hard-coded credentials, such as a password or a cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.CVE-2021-32993 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated... | [] | null | null | 8.1 | null |
ICSA-22-349-01 | Prosys OPC UA Simulation Server (Update A) | Prosys OPC UA Simulation server v5.03-64 does not sufficiently protect credentials, which could allow an attacker to obtain user credentials and gain access to system data. CVE-2022-2967 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/U... | [] | null | null | 6.5 | null |
ICSA-23-271-02 | DEXMA DexGate | The affected product is vulnerable to a cross-site scripting vulnerability, which could allow an attacker to access the web application to introduce arbitrary Java Script by injecting an XSS payload into the 'hostname' parameter of the vulnerable software. The affected product is vulnerable to a cross-site request forg... | [] | null | 5.3 | null | null |
ICSA-19-036-05 | Kunbus PR100088 Modbus Gateway (Update B) | An attacker may be able change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.CVE-2019-6527 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H). Regi... | [] | null | null | 7.2 | null |
ICSA-22-104-14 | Siemens SIMATIC STEP 7 (TIA Portal) | An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server. | [] | null | 6.4 | null | null |
ICSA-20-170-04 | Rockwell Automation FactoryTalk Services Platform | The affected product 's redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges.CVE-2020-12033 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the... | [] | null | null | 7.5 | null |
ICSA-19-003-02 | Yokogawa Vnet/IP Open Communication Driver | The Vnet/IP Open Communication Driver has a vulnerability that could allow an attacker to stop the communications functionality of the Vnet/IP Open Communication Driver, resulting in a denial of service.CVE-2018-16196 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vec... | [] | null | null | 7.5 | null |
ICSA-22-223-03 | Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70 | A memory corruption vulnerability exists in the XML-parsing ParseAttribs functionality of AT&T Labs ' Xmill 0.7. A specially crafted XML file can lead to a heap buffer overflow. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21810 has been assigned to this vulnerability. A CVSS v3 base ... | [] | null | null | 9.8 | null |
ICSMA-18-025-01 | Philips IntelliSpace Cardiovascular System Vulnerability | The ISCV application has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authenti... | [] | null | null | 6.7 | null |
ICSA-20-126-02 | SAE IT-systems FW-50 Remote Telemetry Unit (RTU) | The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users. A specially crafted request could allow an attacker to view the file structure of the affected device and access files that should be inaccessible. | [] | null | null | 9.1 | null |
ICSA-23-075-03 | Siemens RUGGEDCOM CROSSBOW V5.2 | The client query handler of the affected application fails to check for proper permissions for specific write queries. This could allow an authenticated remote attacker to perform unauthorized actions. The client query handler of the affected application fails to check for proper permissions when assigning groups to us... | [] | null | 6.6 | null | null |
ICSA-22-041-04 | Siemens SINEMA Remote Connect Server | Affected products contain an open redirect vulnerability.
An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks. | [] | null | 5.4 | null | null |
ICSA-21-138-01 | ICSA-21-138-01_Emerson Rosemount X-STREAM | The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access.CVE-2021-27457 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S... | [] | null | null | 5.4 | null |
ICSA-24-156-01 | Uniview NVR301-04S2-P4 (Update A) | The affected product is vulnerable to reflected cross-site scripting attack (XSS). An attacker could send a user a URL that if clicked on could execute malicious JavaScript in their browser. This vulnerability affects both authenticated and unauthenticated pages under the /LAPI/ directory. As session data is unavailabl... | [] | null | 6.1 | null | null |
ICSA-21-159-04 | Schneider Electric IGSS | Exploitation of this vulnerability could result in loss of data or remote code execution due to missing length checks when a malicious CGF file is imported to IGSS Definition.CVE-2021-22750 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/... | [] | null | null | 7.8 | null |
ICSA-22-104-10 | Siemens SICAM A8000 | Affected devices do not require an user to be authenticated to access certain files. This could allow unauthenticated attackers to download these files. | [] | null | 5.3 | null | null |
ICSA-20-343-03 | Schneider Electric Easergy T300 | The affected product is vulnerable to a missing authentication for critical function vulnerability, which may allow an attacker to expose information, cause a denial-of-service condition, and remotely execute arbitrary code.CVE-2020-7561 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been cal... | [] | null | null | 6.3 | null |
ICSA-21-280-03 | Johnson Controls exacqVision | The affected product is vulnerable to an integer overflow vulnerability, which may allow an attacker to cause a denial-of-service condition.CVE-2021-27665 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-21-208-05 | Delta Electronics DIAScreen | DIAScreen is vulnerable to type confusion, which may allow an attacker to remotely execute arbitrary code.CVE-2021-32965 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-23-222-11 | Siemens Solid Edge SE2023 | The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. The affected applications contain an out of bounds read past the end of an allocated structure whil... | [] | null | 7.8 | null | null |
ICSA-20-105-01 | Eaton HMiSoft VU3 | A specially crafted input file could cause a buffer overflow when loaded by the affected product.CVE-2020-10639 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A specially crafted input file could trigger an out-o... | [] | null | null | 3.3 | null |
ICSA-21-350-10 | Siemens JT2Go and Teamcenter Visualization | The DL180pdfl.dll contains an out of bounds write past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14974) The Jt1001.dll contains an out of bounds write past the end of an allocated structure wh... | [] | null | 3.3 | null | null |
ICSA-21-061-03 | MB connect line mbCONNECT24, mymbCONNECT24 | Improper access validation may allow a logged-in user to see devices in an account to which they should not have access.CVE-2020-12527 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N). Improper access validation may... | [] | null | null | 7.8 | null |
ICSA-24-046-02 | Siemens SIDIS Prime | In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man in the middle attackers to reuse encrypted user credentials sent over the network. Server or client applications that call the SSL_check_c... | [] | null | 7.5 | null | null |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.