id stringlengths 12 16 | title stringlengths 6 140 | description stringlengths 76 139k | cpes listlengths 0 0 | cvss_v4_0 null | cvss_v3_1 float64 2.5 10 ⌀ | cvss_v3_0 float64 1.9 10 ⌀ | cvss_v2_0 null |
|---|---|---|---|---|---|---|---|
ICSA-23-131-08 | Teltonika Remote Management System and RUT Model Routers | Teltonika’s Remote Management System versions prior to 4.10.0 contain a function that allows users to claim their devices. This function returns information based on whether the serial number of a device has already been claimed, the MAC address of a device has already been claimed, or whether the attempt to claim a de... | [] | null | null | 8.8 | null |
ICSMA-23-061-01 | Medtronic Micro Clinician and InterStim Apps | Medtronic Clinician (A51200) and InterStim X Clinicain App (A51300) contain a vulnerability that exists under certain reset conditions, which could cause the clinician application’s custom password to be reset to a default password. This could result in unauthorized control of the clinician therapy application, which h... | [] | null | null | 6.4 | null |
ICSA-19-344-04 | Siemens SIMATIC Products (Update C) | Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection.
This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices. | [] | null | 3.7 | null | null |
ICSA-20-177-02 | Rockwell Automation FactoryTalk Services Platform XXE | A local, authenticated attacker could use an XML External Entity (XXE) attack to exploit weakly configured XML files to access local or remote content. A successful exploit could potentially cause a denial-of-service condition and allow the attacker to arbitrarily read any local file via system-level services.CVE-2020-... | [] | null | null | 8.4 | null |
ICSA-24-051-01 | Commend WS203VICM | A remote, unauthenticated attacker may be able to send crafted messages to the web server of the Commend WS203VICM causing the system to restart, interrupting service. A remote attacker may be able to bypass access control of Commend WS203VICM by creating a malicious request. A weak encoding is used to transmit credent... | [] | null | 5.7 | null | null |
ICSA-20-065-01 | WAGO I/O-CHECK | A specially crafted packet could cause the server to send back packets containing data from the stack.CVE-2019-5073 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). The affected products are vulnerable to a buffer ... | [] | null | null | 10 | null |
ICSA-22-053-02 | GE Proficy CIMPLICITY-Cleartext | CVE-2022-21798 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 7.5 | null |
ICSMA-20-261-01 | ICSMA-20-261-01_Philips Clinical Collaboration Platform | The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.CVE-2020-14506 has been assigned to this vulnerability. A CVSS v3 base score of 3.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:... | [] | null | null | 6.8 | null |
ICSA-21-047-01 | Open Design Alliance Drawings SDK (Update A) | Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892) Affected applications lack proper validation of user-supp... | [] | null | 7.8 | null | null |
ICSA-22-053-01 | GE Proficy CIMPLICITY-IPM | Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed f... | [] | null | null | 7.5 | null |
ICSMA-19-297-01 | Philips IntelliSpace Perinatal | A vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to break-out from the containment of the application and access unauthorized resources from t... | [] | null | null | 6.1 | null |
ICSA-21-182-01 | Johnson Controls Facility Explorer | Sending specifically crafted web messages to the Facility Explorer SNC Series Supervisory Controller (F4-SNC) could give an authenticated F4-SNC user unintended access to the controller 's file system, which may allow an attacker to access or modify system files.CVE-2021-27661 has been assigned to this vulnerability. A... | [] | null | null | 8.8 | null |
ICSA-18-240-03 | Schneider Electric PowerLogic PM5560 | The PowerLogic PM5560 product is susceptible to cross-site scripting attack on its web browser. An attacker may be able to manipulate inputs to cause execution of java script code.CVE-2018-7795 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L... | [] | null | null | 8.2 | null |
ICSA-22-314-09 | Siemens Teamcenter Visualization and JT2Go | The affected application is vulnerable to fixed-length heap-based buffer while parsing specially crafted TIF files. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2022-39136 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated... | [] | null | 7.8 | null | null |
ICSA-19-073-02 | Gemalto Sentinel UltraPro | The uncontrolled search path element vulnerability enables an attacker to load and execute a malicious file from the ux32w.dll in Sentinel UltraPro.CVE-2019-6534 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 6.5 | null |
ICSA-20-238-02 | Emerson OpenEnterprise | Inadequate encryption may allow the credentials used by OpenEnterprise to access field devices and external systems to be obtained.CVE-2020-16235 has been assigned to this vulnerability. A CVSS v3 base score of 3.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N). | [] | null | null | 3.8 | null |
ICSA-18-212-01 | Davolink DVW-3200N | The device generates a weak password hash that is easily cracked, allowing a remote attacker to obtain the password for the device.CVE-2018-10618 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-22-314-04 | Siemens SINUMERIK ONE and SINUMERIK MC | Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication.
This could allow attackers to discover the private key of a CPU product family ... | [] | null | 9.3 | null | null |
ICSA-20-287-04 | Fieldcomm Group HART-IP and hipserver | A malicious attacker could exploit this interface by constructing HART-IP messages with sufficiently large payloads to overflow the internal buffer and crash the device, or obtain control of the device.CVE-2020-16209 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vect... | [] | null | null | 9.8 | null |
ICSA-20-042-11 | Siemens SIMATIC S7-1500 (Update A) | Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems.... | [] | null | 7.5 | null | null |
ICSA-22-349-10 | Siemens APOGEE/TALON Field Panels | A buffer overrun can be triggered in X.509 certificate verification, specifically in name constraint checking. Note that this occurs after certificate chain signature verification and requires either a CA to have signed the malicious certificate or for the application to continue certificate verification despite failur... | [] | null | 7.5 | null | null |
ICSA-21-194-17 | Siemens SINUMERIK ONE and SINUMERIK MC (Update A) | Affected devices are vulnerable to a memory protection bypass through a specific operation.
A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks. | [] | null | 8.1 | null | null |
ICSA-23-082-06 | ProPump and Controls Osprey Pump Controller (Update A) | Osprey Pump Controller versions prior to release 20230518 are vulnerable to a predictable weak session token generation algorithm and could aid in authentication and authorization bypass. This could allow a cyber threat actor to hijack a session by predicting the session ID and gain unauthorized access to the product. ... | [] | null | null | 8.2 | null |
ICSA-17-234-04 | General Motors and Shanghai OnStar (SOS) iOS Client | Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory.CVE-2017-9663 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Successful ex... | [] | null | null | 8.8 | null |
ICSA-22-228-03 | Delta Industrial Automation DRAS | The software processes an XML document that could contain XML entities with URIs that resolve to documents outside of the intended sphere of control, causing the product to embed incorrect documents into its output. This may allow an attacker to view sensitive documents and information on the affected host.CVE-2022-275... | [] | null | null | 5.5 | null |
ICSA-21-278-02 | Emerson WirelessHART Gateway | The affected product is vulnerable to a missing permission validation on system backup restore, which could lead to account take over and unapproved settings change.CVE-2021-42539has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:... | [] | null | null | 8 | null |
ICSA-19-024-01 | Advantech WebAccess/SCADA | An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.CVE-2019-6519 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Special... | [] | null | null | 5.3 | null |
ICSA-24-226-03 | Rockwell Automation GuardLogix/ControlLogix 5580 Controller | A denial-of-service vulnerability exists in the affected products. The vulnerability occurs when a malformed CIP packet is sent over the network to the device and results in a major nonrecoverable fault causing a denial-of-service. | [] | null | 7.5 | null | null |
ICSA-23-304-02 | INEA ME RTU | Versions of INEA ME RTU firmware 3.36b and prior are vulnerable to operating system (OS) command injection, which could allow remote code execution. Versions of INEA ME RTU firmware 3.36b and prior do not require authentication to the "root" account on the host system of the device. This could allow an attacker to obta... | [] | null | 9.8 | null | null |
ICSA-18-347-04 | GE Mark VIe, EX2100e, EX2100e | The affected versions of the application have a path traversal vulnerability that fails to restrict the ability of an attacker to gain access to restricted information.CVE-2018-19003 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/... | [] | null | null | 7.4 | null |
ICSA-20-098-02 | GE Digital CIMPLICITY | A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated ... | [] | null | null | 6 | null |
ICSA-21-075-01 | Advantech WebAccess/SCADA | The affected product is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user 's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions.CVE-2021-27436 ha... | [] | null | null | 5.4 | null |
ICSA-22-104-15 | Siemens Simcenter Femap | The affected application contains an out of bounds read past the end of an allocated buffer while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15114) The affected application contains an out of bounds write past the end of an allocate... | [] | null | 7.8 | null | null |
ICSA-22-298-04 | Hitachi Energy MicroSCADA X DMS600 | A vulnerability exists when Hitachi Energy MicroSCADA X DMS600 v4.5 uses an affected version of PostgreSQL. While modifying certain SQL array values, missing bounds checks let authenticated database users write arbitrary bytes to a wide area of server memory. Successful exploitation of this vulnerability could allow at... | [] | null | null | 6.5 | null |
ICSA-23-290-01 | Schneider Electric EcoStruxure Power Monitoring Expert and Power Operation Products | A deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application. | [] | null | null | 9.8 | null |
ICSA-22-202-01 | ABB Drive Composer, Automation Builder, Mint Workbench | Vulnerabilities in Drive Composer allow a low-privileged user to create and write to a file anywhere on the file system as system with arbitrary content when the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a repair operation on the product.CVE-2022-31216 has been a... | [] | null | null | 6.7 | null |
ICSA-23-103-04 | Siemens TIA Portal | Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. | [] | null | 7.3 | null | null |
ICSA-23-348-06 | Siemens OPC UA Implementation in SINUMERIK ONE and SINUMERIK MC | The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.
This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially cr... | [] | null | 7.5 | null | null |
ICSA-20-210-03 | HMS Industrial Networks eCatcher | The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.CVE-2020-14498 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H). | [] | null | null | 9.6 | null |
ICSA-23-234-03 | Rockwell Automation ThinManager ThinServer | Due to improper input validation, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message. Due to i... | [] | null | null | 9.8 | null |
ICSA-19-274-03 | Moxa EDR 810 Series | An authenticated attacker may abuse the ping feature to execute unauthorized commands on the router, which could allow an attacker to perform remote code execution.CVE-2019-10969 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/... | [] | null | null | 4.3 | null |
ICSMA-21-012-01 | SOOIL Dana Diabecare RS Products | A hard-coded physician PIN in the physician menu of the insulin pump allows attackers with physical access to change insulin therapy settings.CVE-2020-27256 has been assigned to this vulnerability. A CVSS v3 base score of 4.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). An infor... | [] | null | null | 5.7 | null |
ICSA-23-143-03 | Mitsubishi Electric MELSEC Series CPU module (Update C) | A vulnerability due to copying buffers without checking size of input exists in these MELSEC Series CPU modules. Exploitation may allow denial of service and malicious code execution. | [] | null | null | 10 | null |
ICSA-21-012-03 | Siemens JT2Go and Teamcenter Visualization (Update B) | Affected applications lack proper validation of user-supplied data when parsing JT files. A crafted JT file can trigger a type of confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. CVE-2020-26980 has been assigned to this vulnerability. A CVSS v3 base... | [] | null | null | 7.8 | null |
ICSA-19-057-01 | Moxa IKS, EDS (Update A) | Several buffer overflow vulnerabilities have been identified, which may allow remote code execution.CVE-2019-6557 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). A cross-site request forgery has been identified, w... | [] | null | null | 7.5 | null |
ICSA-21-257-12 | Siemens SINEMA Server | Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges. | [] | null | 4.7 | null | null |
ICSA-23-334-03 | PTC KEPServerEx | KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information. KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect. | [] | null | 7.5 | null | null |
ICSA-22-258-05 | Siemens SINEC INS | The package ua-parser-js before 0.7.23 are vulnerable to Regular Expression Denial of Service (ReDoS) in multiple regexes (see linked commit for more info). json-c through 0.14 has an integer overflow and out-of-bounds write via a large JSON file, as demonstrated by printbuf_memappend. Axios NPM package 0.21.0 contains... | [] | null | 5.3 | null | null |
ICSA-18-107-05 | ICSA-18-107-05_Rockwell Automation Stratix Industrial Managed Ethernet Switch | A format string vulnerability in the LLDP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an adjacent, unauthenticated attacker to cause a DoS condition or execute arbitrary code with elevated privileges.CVE-2018-0167 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been ca... | [] | null | null | 8.8 | null |
ICSA-17-234-02 | SpiderControl SCADA MicroBrowser | Opening a maliciously crafted html file may cause a stack overflow.CVE-2017-12707 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). | [] | null | null | 7.3 | null |
ICSA-23-264-04 | Rockwell Automation Select Logix Communication Modules | A buffer overflow vulnerability exists in the 1756 EN2T communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device. | [] | null | null | 9.8 | null |
ICSA-22-067-01 | PTC Axeda agent and Axeda Desktop Server (Update C) | The affected product uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.CVE-2022-25246 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been ... | [] | null | null | 7.5 | null |
ICSA-20-252-06 | Siemens SIMATIC HMI Products (Update A) | Affected devices insufficiently block excessive authentication attempts.
This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only... | [] | null | 5.3 | null | null |
ICSA-22-195-02 | Siemens SICAM GridEdge | Affected software uses an improperly protected file to import SSH keys. Attackers with access to the filesystem of the host on which SICAM GridEdge runs, are able to inject a custom SSH key to that file. | [] | null | 6.3 | null | null |
ICSA-19-017-02 | ABB CP400 Panel Builder TextEditor 2.0 | The application contains a vulnerability in the file parser of the Text Editor wherein the application doesn 't properly prevent the insertion of specially crafted files.CVE-2018-19008 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:... | [] | null | null | 7 | null |
ICSA-21-217-03 | ICSA-21-217-03_mySCADA myPRO | The affected product does not restrict unauthorized read access to sensitive system information.CVE-2021-33013 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N). The affected product allows an unauthenticated remote ... | [] | null | null | 7.5 | null |
ICSMA-18-233-01 | Philips IntelliVue Information Center iX (Update B) | An attacker may compromise the device 's availability by performing multiple initial UDP requests.CVE-1999-0103 has been assigned to this vulnerability. A CVSS v3 base score of 5.7 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 5.7 | null |
ICSA-22-263-02 | Hitachi Energy AFF660/665 Series | An improper parsing of URL arguments allows an attacker to exploit this vulnerability by crafting specially formed HTTP requests to overflow an internal buffer. Successful exploitation could cause a full compromise of the device.CVE-2020-6994 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been... | [] | null | null | 9.8 | null |
ICSMA-20-163-01 | Philips IntelliBridge Enterprise IBE | Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal.
The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the E... | [] | null | null | 2 | null |
ICSA-22-195-13 | Siemens Mendix | In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords. | [] | null | 4.9 | null | null |
ICSA-20-105-05 | Siemens RUGGEDCOM, SCALANCE, SIMATIC, SINEMA (Update B) | Linux kernel versions 4.9+ can be forced to make very expensive calls to tcp_collapse_ofo_queue() and tcp_prune_ofo_queue() for every incoming packet which can lead to a denial of service. The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting... | [] | null | 7.5 | null | null |
ICSA-22-132-01 | Delta Electronics CNCSoft | The affected product does not properly sanitize input while processing a specific project file, allowing a possible stack-based buffer overflow condition.CVE-2022-1405 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H... | [] | null | null | 3.3 | null |
ICSA-19-092-01 | Advantech WebAccess/SCADA | Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.CVE-2019-6552 has been assigned to these vulnerabilities. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) Multiple sta... | [] | null | null | 7.5 | null |
ICSA-22-132-10 | Siemens Desigo PXC and DXR Devices | The addCell JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document as it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges could corrupt the content used to g... | [] | null | null | 7.5 | null |
ICSA-24-235-02 | Rockwell Automation 5015 - AENFTXT | An input validation vulnerability exists in the affected products when a manipulated PTP packet is sent, causing the secondary adapter to result in a major nonrecoverable fault. If exploited, a power cycle is required to recover the product. | [] | null | 7.5 | null | null |
ICSMA-18-277-01 | Carestream Vue RIS | When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack.CVE-2018-17891 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the ... | [] | null | null | 3.7 | null |
ICSA-24-086-02 | Rockwell Automation PowerFlex 527 | A denial-of-service vulnerability exists in the PowerFlex 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it. A denial-of-service vulnerability exists in the PowerFlex 527 due to improper input validation in the device. If exploited, a d... | [] | null | 7.5 | null | null |
ICSA-23-222-02 | Siemens Parasolid Installer | Nullsoft Scriptable Install System (NSIS) before v3.09 creates an "uninstall directory" with insufficient access control. This could allow an attacker to misuse the vulnerability, and potentially escalate privileges. | [] | null | 7.8 | null | null |
ICSA-21-308-02 | AzeoTech DAQFactory | The affected application uses specific functions that could be abused through a crafted project file, which could lead to code execution, system reboot, and system shutdown.CVE-2021-42543 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/... | [] | null | null | 5 | null |
ICSA-23-220-01 | Schneider Electric IGSS | A deserialization of untrusted data vulnerability that could cause an interpretation of malicious payload data exists in the Dashboard module, which could lead to arbitrary code execution if an attacker gets the user to open a malicious file. A missing authentication for critical function vulnerability that could allow... | [] | null | null | 7.8 | null |
ICSA-19-050-01 | Intel Data Center Manager SDK | Insufficient session authentication may allow an unauthenticated user to enable escalation of privilege via network access.CVE-2019-0102 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Insufficient file protection... | [] | null | null | 4 | null |
ICSA-23-017-03 | Siemens SINEC INS | In addition to the c_rehash shell command injection identified in CVE-2022-1292, further circumstances where the c_rehash script does not properly sanitise shell metacharacters to prevent command injection were found by code review. When the CVE-2022-1292 was fixed it was not discovered that there are other places in t... | [] | null | 8.4 | null | null |
ICSA-21-285-02 | Advantech WebAccess | The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code.CVE-2021-33023 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product is vulne... | [] | null | null | 9.8 | null |
ICSA-17-332-01 | Siemens SCALANCE W1750D, M800, S615, and RUGGEDCOM RM1224 (Update C) | An attacker could cause a crash of the DNSmasq process by sending specially crafted request messages to the service on port 53/udp. An attacker could cause a crash or potentially execute arbitrary code by sending specially crafted DNS responses to the DNSmasq process. In order to exploit this vulnerability, an attacker... | [] | null | 5.3 | null | null |
ICSA-23-082-01 | RoboDK | RoboDK versions 5.5.3 and prior contain an insecure permission assignment to critical directories vulnerability, which could allow a local user to escalate privileges and write files to the RoboDK process and achieve code execution. CVE-2023-1516 has been assigned to this vulnerability. A CVSS v3 base score of 7.9 has... | [] | null | null | 7.9 | null |
ICSA-23-285-05 | Siemens Simcenter Amesim | The affected application contains a SOAP endpoint that could allow an unauthenticated remote attacker to perform DLL injection and execute arbitrary code in the context of the affected application process. | [] | null | 9.8 | null | null |
ICSA-21-315-09 | Siemens Climatix POL909 (Update A) | The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.CVE-2021-40366 has been assigned to this vulnerability. A CVSS v3 base score ... | [] | null | null | 6.4 | null |
ICSA-21-292-01 | AUVESY Versiondog | The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.CVE-2021-38457 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N... | [] | null | null | 8 | null |
ICSA-22-104-17 | Siemens Mendix | When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field. | [] | null | 3.1 | null | null |
ICSA-21-348-01 | Advantech R-SeeNet | Advantech is aware of multiple SQL injection vulnerabilities in the following pages: group_list, company_list, user_list, and device_list. An attacker could send a specially crafted HTTP request to trigger the vulnerabilities.CVE-2021-21915, CVE-2021-21916, CVE-2021-21917, CVE-2021-21918, CVE-2021-21919, CVE-2021-21920... | [] | null | null | 8.8 | null |
ICSA-21-257-17 | Siemens Desigo CC Family | The application deserialises untrusted data without sufficient validations, that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system. The CCOM communication component used for Windows App / Click-Once and IE Web / XBAP client connectivity are... | [] | null | 10 | null | null |
ICSA-21-341-02 | Hitachi Energy XMC20 and FOX61x | This vulnerability is a weak default credential associated with TCP Port 26. Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the DCN routing configuration.CVE-2021-40333 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been calculated; the CVS... | [] | null | null | 8.6 | null |
ICSA-18-233-01 | Yokogawa iDefine, STARDOM, ASTPLANNER, and TriFellows | This vulnerability that affects the license management function when it receives specially crafted data. An attacker could overflow the buffer by exploiting this, which may result in the license management function stopping or result in arbitrary code execution.CVE-2018-0651 has been assigned to this vulnerability. A C... | [] | null | null | 8.6 | null |
ICSA-23-080-07 | Siemens SCALANCE Third-Party | stack_protect_prologue in cfgexpand.c and stack_protect_epilogue in function.c in GNU Compiler Collection (GCC) 4.1 through 8 (under certain circumstances) generate instruction sequences when targeting ARM targets that spill the address of the stack protector guard, which allows an attacker to bypass the protection of ... | [] | null | 6.1 | null | null |
ICSA-23-138-01 | Carlo Gavazzi Powersoft | Carlo Gavazzi Powersoft versions 2.1.1.1 and prior have a directory traversal vulnerability that can allow an attacker to access and retrieve any file through specially crafted GET requests to the server. | [] | null | null | 7.5 | null |
ICSA-17-222-01 | SIMPlight SCADA Software | The uncontrolled search path element vulnerability has been identified, which may allow an attacker to place a malicious DLL file within the search path resulting in execution of arbitrary code.CVE-2017-9661 has been assigned to this vulnerability. A CVSS v3 base score of 7.0 has been assigned; the CVSS vector string i... | [] | null | null | 7 | null |
ICSA-23-012-05 | SAUTER Controls Nova 200 - 220 Series (PLC 6) | SAUTER Controls Nova 200-220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and mod... | [] | null | null | 7.5 | null |
ICSA-24-051-01 | Commend WS203VICM | A remote, unauthenticated attacker may be able to send crafted messages to the web server of the Commend WS203VICM causing the system to restart, interrupting service. A remote attacker may be able to bypass access control of Commend WS203VICM by creating a malicious request. A weak encoding is used to transmit credent... | [] | null | 5.7 | null | null |
ICSA-23-306-03 | Mitsubishi Electric MELSEC Series | A denial-of-service vulnerability exists in the MELSEC-F Series main modules and MELSEC iQ-F Series CPU modules. A remote attacker may be able to reset the memory of the products to factory default state and cause a denial-of-service condition on the products by sending specific packets. | [] | null | 9.1 | null | null |
ICSA-23-131-10 | Rockwell Automation Arena Simulation Software | Rockwell Automation Arena Simulation software v16.00 is vulnerable due to a memory buffer overflow, which could allow a malicious user to commit unauthorized arbitrary code. CVE-2023-29460 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/U... | [] | null | null | 7.8 | null |
ICSA-23-299-03 | Ashlar-Vellum Cobalt, Graphite, Xenon, Argon, Lithium | In Ashlar-Vellum Cobalt, Xenon, Argon, Lithium, and Cobalt Share v12 SP0 Build (1204.77), the affected applications lack proper validation of user-supplied data when parsing XE files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the... | [] | null | null | 7.8 | null |
ICSA-18-102-01 | Yokogawa CENTUM and Exaopc | A weakness in access controls may allow a local attacker to exploit the message management function of the system.CVE-2018-8838 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H). | [] | null | null | 6.5 | null |
ICSA-21-068-01 | Siemens SIMATIC S7-PLCSIM | An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service. An attacker with local access to th... | [] | null | 5.5 | null | null |
ICSA-21-336-05 | Hitachi Energy Relion 670/650/SAM600-IO | A vulnerability exists in the early boot process of the product in which there is a tiny time gap where a previous version of VxWorks is loaded prior to booting up the complete application firmware. The older version of VxWorks is susceptible to Urgent/11, which may allow for remote code execution on the device before ... | [] | null | null | 8.1 | null |
ICSA-20-287-02 | LCDS LAquis SCADA | An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the application due to an out-of-bounds read vulnerability.CVE-2020-25188 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string... | [] | null | null | 7.8 | null |
ICSA-18-191-03 | Tridium Niagara | A path traversal vulnerability in Tridium Niagara AX and Niagara 4 systems installed on Microsoft Windows Systems can be exploited by leveraging valid platform (administrator) credentials.CVE-2017-16744 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (... | [] | null | null | 7.4 | null |
ICSMA-19-029-02 | BD FACSLyric (Update A) | The system does not properly enforce user access control to a privileged account, which may allow for unauthorized access to administrative level functions.CVE-2019-6517 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A... | [] | null | null | 6.8 | null |
ICSA-21-336-06 | Hitachi Energy APM Edge | An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer derefer... | [] | null | null | 8.2 | null |
ICSA-19-064-01 | Rockwell Automation RSLinx Classic | An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition.CVE-2019-6553 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; t... | [] | null | null | 10 | null |
ICSA-23-353-01 | Subnet Solutions Inc. PowerSYSTEM Center | Subnet Solutions PowerSYSTEM Center versions 2020 v5.0.x through 5.16.x contain a vulnerability that could allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges. | [] | null | null | 7.8 | null |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.