ICSA-21-350-19
Siemens SiPass Integrated
Affected applications insufficiently limit the access to the internal message broker system. This could allow an unauthenticated remote attacker to subscribe to arbitrary message queues. Affected applications insufficiently limit the access to the internal activity feed database. This could allow an unauthenticated r...
[]
null
7.5
null
null
ICSA-21-224-01
Cognex In-Sight OPC Server
The affected product deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation.CVE-2021-32935 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/...
[]
null
null
8.8
null
ICSA-20-098-04
Fuji Electric V-Server Lite
The buffer allocated to read data, when parsing VPR files, is too small.CVE-2020-10646 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSMA-22-151-02
BD Synapsys
The affected product is vulnerable due to an insufficient session expiration. An unauthorized physical breach of a BD Synapsys workstation would be negligible due to the sequence of events that must occur in a specific order, however successful exploitation could lead to modification of ePHI, PHI, or PII. The result co...
[]
null
null
5.7
null
ICSA-22-314-10
Siemens SCALANCE W1750D
The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The a...
[]
null
6.1
null
null
ICSA-21-131-09
Siemens Mendix Excel Importer Module
Uploading a manipulated XML File results in an exception that could expose information about the Application-Server and the used XML-Framework.
[]
null
4.3
null
null
ICSA-20-177-01
ENTTEC Lighting Controllers (Update A)
The lighting controller products include hard-coded SSH keys for remote SSH and SCP access as the root user.CVE-2019-12776 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). Several stored XSS vulnerabilities have be...
[]
null
null
8.8
null
ICSA-21-166-01
ThroughTek P2P SDK
The affected ThroughTek P2P products do not sufficiently protect data transferred between the local device and ThroughTek servers. This can allow an attacker to access sensitive information, such as camera feeds.CVE-2021-32934 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the...
[]
null
null
9.1
null
ICSA-19-113-01
Rockwell Automation MicroLogix 1400 and CompactLogix 5370 Controllers
An open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user 's machine.CVE-2019-10955 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CV...
[]
null
null
7.1
null
ICSA-19-003-03
Hetronic Nova-M
These devices use fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent stop state.CVE-2018-19023 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been ...
[]
null
null
7.6
null
ICSA-18-011-02
Moxa MXview
The unquoted service path escalation vulnerability could allow an authorized user with file access to escalate privileges by inserting arbitrary code into the unquoted service path. CVE-2017-14030 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/A...
[]
null
null
7.8
null
ICSA-24-074-05
Siemens RUGGEDCOM APE1808
A heap-based buffer overflow vulnerability in the SOCKS5 proxy handshake in the Curl package. If Curl is unable to resolve the address itself, it passes the hostname to the SOCKS5 proxy. However, the maximum length of the hostname that can be passed is 255 bytes. If the hostname is longer, then Curl switches to the loc...
[]
null
9.8
null
null
ICSA-23-257-05
Siemens SIMATIC IPCs
Information exposure through microarchitectural state after transient execution in certain vector execution units for some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access.
[]
null
6.5
null
null
ICSA-18-151-02
GE MDS PulseNET and MDS PulseNET Enterprise
Java Remote Method Invocation (RMI) input port may be exploited to allow unauthenticated users to launch applications and support remote code execution through Web Services.CVE-2018-10611 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/...
[]
null
null
4.3
null
ICSA-22-111-02
Johnson Controls Metasys SCT Pro
The affected product may allow an attacker to identify and forge requests to internal systems by way of a specially crafted request.CVE-2021-36203 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
5.3
null
ICSA-20-224-04
Siemens SCALANCE, RUGGEDCOM
The version of pppd shipped with this product has a vulnerability that may allow an unauthenticated remote attacker to cause a stack buffer overflow, which may allow arbitrary code execution on the target system.
[]
null
9.8
null
null
ICSA-23-348-05
Siemens SIMATIC and SIPLUS Products
The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device. The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflo...
[]
null
7.5
null
null
ICSA-23-073-01
Omron CJ1M PLC
Omron CJ1M unit v4.0 and prior has improper access controls on the memory region where the UM password is stored. If an adversary issues a PROGRAM AREA WRITE command to a specific memory region, they could overwrite the password. This may lead to disabling UM protections or setting a non-ASCII password (non-keyboard ch...
[]
null
null
9.1
null
ICSA-21-315-08
Siemens NX OBJ Translator
The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771). The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointe...
[]
null
3.3
null
null
ICSA-22-195-11
Open Design Alliance Drawings SDK
Open Design Alliance Drawings SDK (all versions prior to 2023.2) is vulnerable to an out-of-bounds read when rendering DWG files after they are opened in the recovery mode. This could allow an attacker to execute code in the context of the current process. Open Design Alliance Drawings SDK (all versions prior to 2023....
[]
null
7.8
null
null
ICSA-17-257-01
LOYTEC LVIS-3ME
The web user interface fails to prevent access to critical files that non administrative users should not have access to, which could allow an attacker to create or modify files or execute arbitrary code.CVE-2017-13996 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been assigned; the CVSS vect...
[]
null
null
7.5
null
ICSA-21-257-23
Siemens SIMATIC and TIM
Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
[]
null
5.3
null
null
ICSA-17-264-03
Digium Asterisk GUI
An OS command injection vulnerability has been identified that may allow the execution of arbitrary code on the system through the inclusion of OS commands in the URL request of the program.CVE-2017-14001 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (...
[]
null
null
8.8
null
ICSA-21-068-07
Siemens TCP Stack of SIMATIC MV400
The underlying TCP stack of the affected products does not correctly validate the sequence number for incoming TCP RST packages. An attacker could exploit this to terminate arbitrary TCP sessions. ISN generator is initialized with a constant value and has constant increments. An attacker could predict and hijack TCP se...
[]
null
7.5
null
null
ICSA-17-208-03
PDQ Manufacturing, Inc. LaserWash, Laser Jet and ProTouch
Affected web-server does not properly verify that provided authentication information is correct.CVE-2017-9630 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H). Username and password are transmitted insecurely.CVE-201...
[]
null
null
7.5
null
ICSA-23-306-06
Schneider Electric SpaceLogic C-Bus Toolkit
Schneider Electric's SpaceLogic C-Bus Toolkit product is vulnerable due to improper privilege management, which could cause remote code execution when the transfer command is used over the network. Schneider Electric's SpaceLogic C-Bus Toolkit product contains a path traversal vulnerability, which could cause tampering...
[]
null
9.8
null
null
ICSA-19-253-03
ICSA-19-253-03_Siemens Industrial Products (Update P)
The kernel can be forced to make very expensive calls for every incoming TCP Selective Acknowledgement (SACK) packet which can lead to a denial-of-service condition. CVE-2019-8460 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U...
[]
null
null
5.3
null
ICSA-20-056-03
Moxa PT-7528 and PT-7828 Series Ethernet Switches
A buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code. CVE-2020-6989 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H ). The affected products u...
[]
null
null
5.3
null
ICSA-18-352-05
Siemens TIM 1531 IRC Modules
The device was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no ...
[]
null
10
null
null
ICSA-19-318-02
Siemens S7-1200 and S7-200 SMART CPUs (Update B)
There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
[]
null
6.8
null
null
ICSA-24-072-01
Schneider Electric EcoStruxure Power Design
All versions of Schneider Electric EcoStruxure Power Design - Ecodial NL, INT, and FR deserializes untrusted data which could allow an attacker to perform code execution when a malicious project file is loaded into the application by a valid user.
[]
null
7.8
null
null
ICSA-19-260-03
Honeywell Performance IP Cameras and Performance NVRs
The integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network.CVE-2019-13523 has been assigned to this vulnerability. A CVSS v3 base score of ...
[]
null
null
5.3
null
ICSA-18-352-04
3S-Smart Software Solutions GmbH CODESYS V3 Products
The application does not properly restrict communication channels, allowing the source of communication packets to be spoofed. CVE-2018-20026 has been assigned to this vulnerability. A CVSS v3 base score of 5.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N). The application suffers...
[]
null
null
9.4
null
ICSMA-20-163-01
Philips IntelliBridge Enterprise IBE
Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal. The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the E...
[]
null
null
2
null
ICSA-18-333-01
INVT Electric VT-Designer
The program populates objects with user supplied input via a file without first checking for validity, allowing attacker supplied input to be written to known memory locations. This may cause the program to crash or allow remote code execution.CVE-2018-18987 has been assigned to this vulnerability. A CVSS v3 base score...
[]
null
null
6.3
null
ICSA-21-238-02
Annke Network Video Recorder
The affected products are vulnerable to a stack-based buffer overflow, which allows an unauthorized remote attacker to execute arbitrary code with the same privileges as the server user (root).CVE-2021-32941 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string...
[]
null
null
9.4
null
ICSA-23-222-06
Siemens Parasolid and Teamcenter Visualization
The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T fil...
[]
null
6.6
null
null
ICSA-17-283-02
JanTek JTC-200
An attacker could perform actions with the same permissions as a victim user, provided the victim has an active session and is induced to trigger the malicious request.CVE-2016-5789 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U...
[]
null
null
9.8
null
ICSMA-18-123-01
Philips Brilliance Computed Tomography (CT) System (Update A)
Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges. Also, attackers may gain acces...
[]
null
null
8.4
null
ICSA-23-145-01
Moxa MXsecurity Series
An remote attacker,who has gained authorization privileges, could execute arbitrary commands on the device. An attacker could bypass authentication for web-based application programmable interfaces (APIs).
[]
null
null
9.8
null
ICSA-22-349-21
Siemens SCALANCE X-200RNA Switch Devices
OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack. sshd in OpenSSH 3.6.1p2 and earlier, when PermitRootLogin is disabled and using PAM keyboard-interactive ...
[]
null
7.8
null
null
ICSA-21-336-03
Distributed Data Systems WebHMI
The authentication algorithm is sound, but the implemented mechanism can be bypassed as the result of a separate weakness primary to the authentication error.CVE-2021-43931 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:...
[]
null
null
10
null
ICSA-20-070-03
Siemens Spectrum Power 5
The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. If deployed according to recommended system configuration, Siemens considers the environmental vector as CR:L/IR:M/AR:H/MAV:A (4.1)...
[]
null
6.1
null
null
ICSA-18-249-01
Ice Qube Thermal Management Center
The web application does not properly authenticate users, which may allow an attacker to gain access to sensitive information.CVE-2017-14026 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L). Passwords are stored in ...
[]
null
null
8.6
null
ICSA-21-229-02
Advantech WebAccess/NMS
The affected product has an improper authentication vulnerability, which may allow unauthorized users to view resources monitored and controlled by the WebAccess/NMS, as well as IP addresses and names of all the devices managed via WebAccess/NMS.CVE-2021-32951 has been assigned to this vulnerability. A CVSS v3 base sco...
[]
null
null
5.3
null
ICSA-24-046-13
Siemens Parasolid
The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process. The affected applications contain a null pointer dereference vulnerability while ...
[]
null
3.3
null
null
ICSA-23-194-04
Siemens SIMATIC MV500 Devices
In libtirpc before 1.3.3rc1, remote attackers could exhaust the file descriptors of a process that uses libtirpc because idle TCP connections are mishandled. This can, in turn, lead to an svc_run infinite loop without accepting new connections. A memory leak problem was found in the TCP source port generation algorithm...
[]
null
8.6
null
null
ICSA-23-040-01
Control By Web X-400, X-600M
Control By Web X-400 devices are vulnerable to a cross-site scripting attack, which could result in private and session information being transferred to the attacker.-CVE-2023-23553 has been assigned to this vulnerability. A CVSS v3 base score of 4.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S...
[]
null
null
9.1
null
ICSA-23-180-02
Schneider Electric EcoStruxure Operator Terminal Expert
Schneider Electric EcoStruxure operator Terminal Expert versions 3.3 SP1 and prior are vulnerable to a code injection attack that could allow an attacker to execute arbitrary code and gain access to all information on the machine.
[]
null
null
7.8
null
ICSA-22-174-02
Yokogawa CAMS for HIS
If an attacker successfully compromises a computer using CAMS for HIS software, they can use credentials from the compromised machine to access data from another machine using CAMS for HIS software. This can lead to a disabling of CAMS for HIS software functions on any affected machines. CVE-2022-30707 has been assigne...
[]
null
null
6.4
null
ICSA-20-273-01
ICSA-20-273-01_MB Connect line mbCONNECT24, mymbCONNECT24
There is a blind SQL injection vulnerability in the knximport component that allows logged in attackers access to arbitrary information. CVE-2020-24569 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L). There is a bl...
[]
null
null
8.8
null
ICSA-18-163-02
Siemens SCALANCE X Switches (Update A)
A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. Use...
[]
null
5.8
null
null
ICSA-19-017-03
ControlByWeb X-320M
The software does not properly prove or insufficiently prove a claim to be correct, which may allow an attacker to cause a denial of service condition.CVE-2018-18881 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). T...
[]
null
null
7.6
null
ICSA-21-313-01
Schneider Electric NMC cards and Embedded Devices
A vulnerability could cause arbitrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file.CVE-2021-22810 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/...
[]
null
null
5.3
null
ICSA-22-195-15
Siemens SIMATIC eaSie Core Package
The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow a remote attacker to trigger a denial of service of the affected system. The underlying MQTT service of affected systems does not perform authentication in the default configuration. This could...
[]
null
10
null
null
ICSA-22-207-01
Inductive Automation Ignition
Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup. CVE-2022-1704 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been assigned; the CVSS vector string is (AV:...
[]
null
null
7.6
null
ICSA-18-107-02
Schneider Electric Triconex Tricon
System calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory. When a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow a...
[]
null
null
7.9
null
ICSA-23-166-01
SUBNET PowerSYSTEM Center
SUBNET PowerSYSTEM Center versions 2020 U10 and prior contain a cross-site scripting vulnerability that may allow an attacker to inject malicious code into report header graphic files that could propagate out of the system and reach users who are subscribed to email notifications. SUBNET PowerSYSTEM Center versions 20...
[]
null
null
6.1
null
ICSA-19-353-02
Equinox Control Expert
The affected product is vulnerable to an SQL injection attack, which may allow an attacker to remotely execute arbitrary code.CVE-2019-18234 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-22-307-01
ETIC Telecom Remote Access Server (RAS) (Update A)
All versions of ETIC Telecom Remote Access Server (RAS) 4.5.0 and prior's web portal is vulnerable to accepting malicious firmware packages that could provide a backdoor to an attacker and provide privilege escalation to the device. All versions of ETIC Telecom Remote Access Server (RAS) 4.5.0 and prior's application p...
[]
null
null
5.9
null
ICSA-23-164-04
Rockwell Automation FactoryTalk Transaction Manager
A denial-of-service vulnerability exists in the affected products. A threat actor could send a modified packet to port 400 exploit this vulnerability. If exploited, the application could crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The user would need ...
[]
null
null
7.5
null
ICSA-19-078-01
AVEVA InduSoft Web Studio and InTouch Edge HMI
The uncontrolled search path element vulnerability allows an attacker to load and execute a malicious file from the ux32w.dll in third-party component Sentinel UltraPro.CVE-2019-6534 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/...
[]
null
null
6.5
null
ICSA-21-047-01
Open Design Alliance Drawings SDK (Update A)
Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892) Affected applications lack proper validation of user-supp...
[]
null
7.8
null
null
ICSA-21-194-14
Siemens RWG Universal Controllers
Sending specially crafted ARP packets to an affected device could cause a partial denial-of-service, preventing the device to operate normally. A restart is needed to restore normal operations.
[]
null
6.5
null
null
ICSA-18-151-01
ICSA-18-151-01_Delta Industrial Automation DOPSoft
The application performs read operations on a memory buffer where the position can be determined by a value read from a .dpa file. This may cause improper restriction of operations within the bounds of the memory buffer, allow remote code execution, alter the intended control flow, allow reading of sensitive informatio...
[]
null
null
7.3
null
ICSA-23-096-04
Korenix Jetwave
Korenix JetWave 4200 Series 1.3.0 and JetWave 3000 Series 1.6.0 are vulnerable to command injection. An attacker could modify the file_name parameter to execute commands as root. CVE-2023-23294 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:N/AC:L/P...
[]
null
null
6.5
null
ICSA-20-072-02
ABB Asset Suite
There is a flaw in the access controls used to limit user access to resources. If an attacker knows, or were to discover, the URL for a resource they do not have permissions to, they would be able to access the resource by browsing directly to the URL.CVE-2019-18998 has been assigned to this vulnerability. A CVSS v3 ba...
[]
null
null
7.1
null
ICSA-21-334-01
Xylem Aanderaa GeoView
The affected product is vulnerable to SQL injection, which could allow an unauthenticated attacker to invoke queries to manipulate the Aanderaa GeoView database server.CVE-2021-41063 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:...
[]
null
null
8.2
null
ICSA-17-355-02
Schneider Electric Pelco VideoXpert Enterprise
By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack.CVE-2017-9964 has been assigned to this vulnerability. A CVSS v3 base score of 6.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:N). Using ...
[]
null
null
7.1
null
ICSA-17-355-01
ICSA-17-355-01_Moxa NPort W2150A and W2250A
The default password is empty on the device. An unauthorized user can access the device without a password. An unauthorized user has the ability to completely compromise the confidentiality and integrity of the wireless traffic.CVE-2017-16727 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been...
[]
null
null
6.5
null
ICSA-19-213-06
LCDS LAquis SCADA LQS File Parsing
Processing a specially crafted project file may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information.CVE-2019-10994 has been assigned to this vulnerability. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N). A type conf...
[]
null
null
7.8
null
ICSA-19-155-01
PHOENIX CONTACT PLCNext AXC F 2152
A remote attacker can exploit a server 's private key by sending carefully constructed UserIdentityTokens encrypted with the Basic128Rsa15 security policy. This could allow an attacker to decrypt passwords even if encrypted with another security policy such as Basic256Sha256. CVE-2018-7559 has been assigned to this vul...
[]
null
null
5.3
null
ICSA-22-102-04
Mitsubishi Electric GT25-WLAN
The affected product is vulnerable to a fragment cache attack as it does not clear fragments from memory when (re)connecting. This may allow an attacker to steal communication contents or inject unauthorized packets. CVE-2020-24586 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been assigned; ...
[]
null
null
5.3
null
ICSA-20-336-01
Schneider Electric EcoStruxure Operator Terminal Expert runtime (Vijeo XD)
An improper privilege management vulnerability exists that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure Operator Terminal Expert.CVE-2020-7544 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been cal...
[]
null
null
7.4
null
ICSA-18-240-04
ABB eSOMS (Update A)
Unauthorized access to the system can be achieved when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Both conditions are required to exploit this vulnerability.CVE-2018-14805 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has b...
[]
null
null
9.8
null
ICSA-23-213-01
APSystems Altenergy Power Control
OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/set_timezone timezone parameter, because of set_timezone in models/management_model.php.
[]
null
null
9.8
null
ICSA-18-275-02
GE Communicator
A malicious HTML file that loads the ActiveX controls trigger the vulnerability via unchecked function calls.CVE-2017-7908 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H).
[]
null
null
7.6
null
ICSA-22-062-01
IPCOMM ipDIO
Persistent cross-site scripting (XSS) in the web interface of ipDIO allows an authenticated remote attacker to introduce arbitrary JavaScript by injecting an XSS payload into specific fields. The XSS payload will be executed when a legitimate user attempts to upload, copy, download, or delete an existing configuration ...
[]
null
null
8.8
null
ICSA-20-161-03
Siemens LOGO! (Update A)
The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 135/tcp. No user interaction is required to exploit this security vulnerabil...
[]
null
9.4
null
null
ICSA-23-262-05
Omron CJ/CS/CP Series
Omron CJ/CS/CP series programmable logic controllers use the FINS protocol, which is vulnerable to brute-force attacks. The controllers do not enforce any rate limit on password guesses to password-protected memory regions.
[]
null
null
7.5
null
ICSA-22-167-17
Siemens SINEMA Remote Connect Server
libcurl keeps previously used connections in a connection pool for subsequent transfers to reuse. Errors in the logic could lead to libcurl reusing wrong connections.CVE-2021-22925 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/...
[]
null
null
8.8
null
ICSA-24-011-11
Siemens Solid Edge
The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could a...
[]
null
7.8
null
null
ICSA-19-036-02
Rockwell Automation EtherNet/IP Web Server Modules
A remote attacker could send a crafted UDP packet to the SNMP service causing a denial-of-service condition to occur until the affected product is restarted.CVE-2018-19016 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N...
[]
null
null
5.3
null
ICSA-22-314-08
Omron NJ/NX-series Machine Automation Controllers
Use of hard-coded credentials vulnerability exists in machine automation controller NJ series models v1.48 and earlier, machine automation controller NX7 series models v1.28 and earlier, machine automation controller NX1 series models v1.48 and earlier, automation software Sysmac Studio models v1.49 and earlier, and pr...
[]
null
null
7.5
null
ICSMA-17-241-01
ICSMA-17-241-01_Abbott Laboratories ' Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI Pacemaker Vulnerabilities
The pacemaker 's authentication algorithm, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. The Accent and Anthem pacemakers transmit unencrypted patient information via RF commun...
[]
null
null
5.3
null
ICSA-20-287-05
Siemens Desigo Insight
The web service does not properly apply input validation for some query parameters in a reserved area. This could allow an authenticated attacker to retrieve data via a content-based blind SQL injection attack. The device does not properly set the X-Frame-Options HTTP Header which makes it vulnerable to Clickjacking at...
[]
null
4.3
null
null
ICSA-20-016-01
Schneider Electric Modicon Controllers (Update A)
This vulnerability could cause a denial-of-service condition in the controller when reading specific memory blocks using Modbus TCP.CVE-2019-6857 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). This vulnerability co...
[]
null
null
7.5
null
ICSA-19-038-02
Siemens EN100 Ethernet Module
Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products...
[]
null
null
5.9
null
ICSA-23-257-06
Siemans WIBU Systems CodeMeter
In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To exploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured a...
[]
null
9
null
null
ICSA-20-308-02
NEXCOM NIO50
The affected product does not properly validate input, which may allow an attacker to execute a denial-of-service attack.CVE-2020-25151 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The affected product transmit...
[]
null
null
4.3
null
ICSA-19-064-01
Rockwell Automation RSLinx Classic
An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition.CVE-2019-6553 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; t...
[]
null
null
10
null
ICSA-23-080-06
Rockwell Automation ThinManager
In affected versions, a path traversal exists when processing a message. An unauthenticated remote attacker could potentially exploit this vulnerability to upload arbitrary files to any directory on the disk drive where ThinServer.exe is installed. The attacker can overwrite existing executable files with attacker-cont...
[]
null
null
7.5
null
ICSA-22-165-03
Mitsubishi Electric MELSEC-Q/L and MELSEC iQ-R
The affected product is vulnerable to an improper input validation in various web functions, which could allow an attacker to perform remote code execution or cause a denial-of-service condition.CVE-2022-25163 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string...
[]
null
null
8.1
null
ICSA-20-091-02
Mitsubishi Electric MELSEC
An attacker can send large amounts of data to the MELSOFT transmission port of the affected MELSEC product to cause a disruption in communication.CVE-2020-5527 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
[]
null
null
5.3
null
ICSA-22-207-02
Honeywell Safety Manager
The affected product uses the unauthenticated Safety Builder protocol, which does not validate or authenticate the download logic. This could allow an attacker to preform remote code execution on the CPU module.CVE-2022-30315 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CV...
[]
null
null
6.8
null
ICSA-21-194-14
Siemens RWG Universal Controllers
Sending specially crafted ARP packets to an affected device could cause a partial denial-of-service, preventing the device to operate normally. A restart is needed to restore normal operations.
[]
null
6.5
null
null
ICSA-22-172-05
Phoenix Contact Classic Line Industrial Controllers
The affected product does not feature a function to authenticate communication protocols, which could allow an unauthorized attacker to change or download the configuration, start or stop services, update or modify the firmware, or shut down the device.CVE-2019-9201 has been assigned to this vulnerability. A CVSS v3 ba...
[]
null
null
9.8
null
ICSA-22-111-02
Johnson Controls Metasys SCT Pro
The affected product may allow an attacker to identify and forge requests to internal systems by way of a specially crafted request.CVE-2021-36203 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
5.3
null
ICSA-18-137-03
Siemens SIMATIC S7-400 CPU (Update A)
The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of ...
[]
null
7.5
null
null
ICSA-21-021-03
Honeywell OPC UA Tunneller
The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code.CVE-2020-27297 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:...
[]
null
null
7.5
null