id
stringlengths
12
16
title
stringlengths
6
140
description
stringlengths
76
139k
cpes
listlengths
0
0
cvss_v4_0
null
cvss_v3_1
float64
2.5
10
cvss_v3_0
float64
1.9
10
cvss_v2_0
null
ICSA-23-173-02
Advantech R-SeeNet
Advantech R-SeeNet is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users. Advantech R-SeeNet allows low-level users to access and load the content of local files.
[]
null
null
8.8
null
ICSA-23-131-13
PTC Vuforia Studio
The local Vuforia web application does not support HTTPS, and federated credentials are passed via basic authentication. CVE-2023-29168 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N). An attacker with local access...
[]
null
null
5.7
null
ICSA-23-353-05
EuroTel ETL3100 Radio Transmitter
EuroTel ETL3100 versions v01c01 and v01x37 does not limit the number of attempts to guess administrative credentials in remote password attacks to gain full control of the system. EuroTel ETL3100 versions v01c01 and v01x37 are vulnerable to insecure direct object references that occur when the application provides dire...
[]
null
9.4
null
null
ICSA-23-320-02
Hitachi Energy MACH System Software
The McFeeder server (distributed as part of SSW package), is susceptible to an arbitrary file write vulnerability on the MAIN computer system. This vulnerability stems from the use of an outdated version of a third-party library, which is used to extract archives up-loaded to McFeeder server. An authenticated malicious...
[]
null
2.7
null
null
ICSA-19-311-02
Fuji Electric V-Server
Several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code.CVE-2019-18240 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-20-287-05
Siemens Desigo Insight
The web service does not properly apply input validation for some query parameters in a reserved area. This could allow an authenticated attacker to retrieve data via a content-based blind SQL injection attack. The device does not properly set the X-Frame-Options HTTP Header which makes it vulnerable to Clickjacking at...
[]
null
4.3
null
null
ICSA-23-187-01
PiiGAB M-Bus
PiiGAB M-Bus does not correctly sanitize user input, which could allow an attacker to inject arbitrary commands. The number of login attempts is not limited. This could allow an attacker to perform a brute force on HTTP basic authentication. PiiGAB M-Bus transmits credentials in plaintext format. PiiGAB M-Bus conta...
[]
null
null
8.8
null
ICSA-19-199-01
Johnson Controls exacqVision Server
Some services have an unquoted service path. If an authenticated user is able to insert code in the system root path, that code can be executed during the application startup.CVE-2019-7590 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L...
[]
null
null
6.7
null
ICSA-21-112-01
Horner Automation Cscape
The affected application lacks proper validation of user-supplied data when parsing project files. This could lead to memory corruption. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-22678 has been assigned to this vulnerability. A CVSS v3 base score of 7.8...
[]
null
null
8.4
null
ICSMA-21-047-01
Hamilton-T1
Hard-Coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device 's configuration interface.CVE-2020-27278 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N). An ...
[]
null
null
2.1
null
ICSA-23-346-01
Schneider Electric Easy UPS Online Monitoring Software
A path traversal vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker.
[]
null
5.3
null
null
ICSA-21-173-01
Advantech WebAccess HMI Designer (Update A)
Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required.CVE-2021-33000 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/P...
[]
null
null
5.4
null
ICSA-23-094-01
Nexx Smart Home Device
The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server (MQTT) server and the ability to remotely control garage doors or smart plugs for ...
[]
null
null
8.1
null
ICSA-21-194-17
Siemens SINUMERIK ONE and SINUMERIK MC (Update A)
Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
[]
null
8.1
null
null
ICSA-19-204-02
NREL EnergyPlus
The application fails to prevent an exception handler from being overwritten with arbitrary code.CVE-2019-10974 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L).
[]
null
null
6.1
null
ICSA-18-263-01
Tec4Data SmartCooler
The device responds to a remote unauthenticated reboot command that may be used to perform a denial of service attack.CVE-2018-14796 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-21-042-02
Rockwell Automation DriveTools SP and Drives AOP
DriveTools and Drives AOP both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system.CVE-2021-22665 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string...
[]
null
null
7.5
null
ICSA-18-072-02
OSIsoft PI Data Archive
Unauthenticated users may modify deserialized data to send custom requests that crash the server. CVE-2018-7529 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). Insecure default configuration may allow escalation o...
[]
null
null
5.9
null
ICSA-22-195-18
Siemens RUGGEDCOM ROS
Affected devices are vulnerable to a web-based code injection attack via the console. An attacker could exploit this vulnerability to inject code into the web server and cause malicious behavior in legitimate users accessing certain web resources on the affected device. CVE-2022-34663 has been assigned to this vuln...
[]
null
8
null
null
ICSA-21-229-01
ThroughTek Kalay P2P SDK
The affected ThroughTek P2P products may be vulnerable to improper access controls. This vulnerability can allow an attacker to access sensitive information (such as camera feeds) or perform remote code execution.CVE-2021-28372 has been assigned to this vulnerability. A CVSS v3 base score 9.8 has been calculated; the C...
[]
null
null
9.6
null
ICSA-18-212-05
AVEVA Wonderware License Server
Buffer overflows in lmgrd and vendor daemon in Flexera FlexNet Publisher may allow remote attackers to execute arbitrary code via a crafted packet, resulting in remote code execution with administrator privileges.CVE-2015-8277 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the...
[]
null
null
9.8
null
ICSA-20-315-02
OSIsoft PI Vision
A remote attacker with write access to PI ProcessBook files could inject code that is imported into PI Vision. Unauthorized information disclosure, modification, or deletion is also possible if a victim views or interacts with the infected display. This vulnerability affects PI System data and other data accessible wit...
[]
null
null
4.9
null
ICSA-24-046-05
Siemens Location Intelligence
Affected products use a hard-coded secret value for the computation of a Keyed-Hash Message Authentication Code. This could allow an unauthenticated remote attacker to gain full administrative access to the application.
[]
null
9.8
null
null
ICSA-23-075-05
Siemens Mendix SAML Module
The affected versions of the module insufficiently verifies the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application.
[]
null
9.1
null
null
ICSA-20-056-03
Moxa PT-7528 and PT-7828 Series Ethernet Switches
A buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code. CVE-2020-6989 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H ). The affected products u...
[]
null
null
5.3
null
ICSA-22-041-03
Siemens Simcenter Femap
Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14754, ZDI-CAN-15082) Affected application contains a type confusion vulnerability while par...
[]
null
7.8
null
null
ICSA-23-166-10
Siemens SIMATIC S7-1500 TM MFP BIOS
The iconv program in the GNU C Library (aka glibc or libc6) 2.31 and earlier, when invoked with multiple suffixes in the destination encoding (TRANSLATE or IGNORE) along with the -c option, enters an infinite loop when processing invalid multi-byte input sequences, leading to a denial of service. The iconv feature in t...
[]
null
6.6
null
null
ICSA-22-195-08
Siemens PADS Standard/Plus Viewer
The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-037, FG-VD-22-059) The affected application contains an out of bounds write past the...
[]
null
3.3
null
null
ICSA-17-129-01
Siemens devices using the PROFINET Discovery and Configuration Protocol (Update K)
Specially crafted PROFINET DCP broadcast packets sent to the affected products on alocal Ethernet segment (Layer 2) could cause a Denial-of-Service condition of someservices. The services require manual restart to recover.
[]
null
null
6.5
null
ICSA-23-264-03
Delta Electronics DIAScreen
Delta Electronics DIAScreen may write past the end of an allocated buffer while parsing a specially crafted input file. This could allow an attacker to execute code in the context of the current process.
[]
null
null
7.8
null
ICSA-20-098-04
Fuji Electric V-Server Lite
The buffer allocated to read data, when parsing VPR files, is too small.CVE-2020-10646 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-22-349-06
Siemens SIMATIC WinCC OA Ultralight Client
The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's cre...
[]
null
5.4
null
null
ICSA-20-128-01
Advantech WebAccess Node
An improper validation vulnerability exists that could allow an attacker to inject specially crafted input into memory where it can be executed.CVE-2020-12022 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Multip...
[]
null
null
6.5
null
ICSA-21-236-03
Delta Electronics TPEditor
A heap-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to execute arbitrary code.CVE-2021-33007 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (...
[]
null
null
7.8
null
ICSA-19-227-04
Siemens SINAMICS (Update C)
The webserver of the affected devices contains a vulnerability that may lead to a denial-of-service condition. An attacker may cause a denial-of-service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the aff...
[]
null
7.5
null
null
ICSA-22-063-01
Trailer Power Line Communications (PLC) J2497
Trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions.CVE-2022-25922 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI...
[]
null
null
9.3
null
ICSA-22-130-02
Eaton Intelligent Power Protector
The affected product is vulnerable to a cross-site scripting vulnerability due to insufficient validation of user input and improper encoding of the output for certain resources within the IPP software.CVE-2021-23283 has been assigned to this vulnerability. A CVSS v3 base score of 5.2 has been calculated; the CVSS vect...
[]
null
null
5.2
null
ICSMA-20-170-03
Baxter Phoenix Hemodialysis Delivery System (Update A)
The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription ...
[]
null
null
7.5
null
ICSMA-20-296-01
B. Braun OnlineSuite
A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files.CVE-2020-25172 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H...
[]
null
null
6.9
null
ICSA-23-012-07
Hitachi Energy Lumada APM
Hitachi Energy Lumada APM has a flaw in the access control mechanism implementation on the “Limited Engineer” role, granting access to the embedded Power BI reports feature. This could allow an unauthorized user to access information by gaining unauthorized access to any installed Power BI reports, then manipulating as...
[]
null
null
5.7
null
ICSA-21-103-09
Siemens LOGO! Soft Comfort
A zip slip vulnerability could be triggered while importing a compromised project file to the affected software. Chained with other vulnerabilities this vulnerability could ultimately lead to a system takeover by an attacker. The software insecurely loads libraries which makes it vulnerable to DLL hijacking. Successful...
[]
null
8.4
null
null
ICSA-24-228-09
Siemens NX
The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
[]
null
7.8
null
null
ICSA-21-040-04
Siemens RUGGEDCOM ROX II
A cached side channel attack during handshakes using RSA encryption could allow for the decryption of encrypted content. This is a variant of the Adaptive Chosen Ciphertext attack (AKA Bleichenbacher attack) and affects all NSS versions prior to NSS 3.41. In Network Security Services (NSS) before 3.36.7 and before 3.41...
[]
null
7.5
null
null
ICSA-19-008-02
Schneider Electric IIoT Monitor (Update A)
A path traversal vulnerability exists, which may allow access to files available to SYSTEM user.CVE-2018-7835 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). An unrestricted upload of a file with dangerous type vu...
[]
null
null
6.2
null
ICSA-24-074-12
Delta Electronics DIAEnergie
Privileges are not fully verified server-side, which can be abused by a user with limited privileges to bypass authorization and access privileged functionality SQL injection vulnerability exists in the script Handler_CFG.ashx. SQL injection vulnerability exists in the script DIAE_tagHandler.ashx. SQL injection vulnera...
[]
null
4.6
null
null
ICSA-18-354-02
Schneider Electric EcoStruxure
Victims of phishing attacks can be redirected to a malicious websites via URL redirection.CVE-2018-7797 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N).
[]
null
null
7.4
null
ICSA-21-180-01
Exacq Technologies exacqVision Web Service
The software does not sufficiently validate, filter, escape, and/or encode user-controllable input before it is placed in output used as a web page, which is served to other users. This may allow an attacker to send malicious requests on behalf of the victim.CVE-2021-27659 has been assigned to this vulnerability. A CVS...
[]
null
null
5.3
null
ICSA-20-147-02
Johnson Controls Kantech EntraPass
There is a vulnerability in Kantech EntraPass that could allow an authorized low-privileged user to gain full system-level privileges by replacing critical files with specifically crafted files.CVE-2020-9046 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string...
[]
null
null
8.8
null
ICSA-22-104-09
Siemens SCALANCE X-300 Switches
Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force se...
[]
null
7.4
null
null
ICSA-20-142-02
Schneider Electric EcoStruxure Operator Terminal Expert
An attacker could exploit an SQL injection vulnerability by enticing a user to open a maliciously crafted project file.CVE-2020-7493 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H). An attacker could exploit this p...
[]
null
null
6.3
null
ICSA-20-170-02
Mitsubishi Electric MC Works64, MC Works32
A specially crafted communication packet sent to the affected MC Works64 Broker64 or MC Works32 Broker32 systems could cause a denial-of-service condition or allow remote code execution.CVE-2020-12011 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV...
[]
null
null
7.5
null
ICSMA-18-228-01
Philips PageWriter TC10, TC20, TC30, TC50, and TC70 Cardiographs (Update A)
The PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.CVE-2018-14799 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). An attacker with both ...
[]
null
null
6.1
null
ICSA-24-268-05
Moxa MXview One
The configuration file stores credentials in cleartext. An attacker with local access rights can read or modify the configuration file, potentially resulting in the service being abused because of sensitive information exposure. The vulnerability allows an attacker to craft MQTT messages that include relative path trav...
[]
null
5.3
null
null
ICSA-21-033-02
Siemens SIMATIC HMI Comfort Panels & SIMATIC HMI KTP Mobile Panels
Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
[]
null
8.1
null
null
ICSA-19-290-02
Horner Automation Cscape
An improper input validation vulnerability has been identified that may be exploited by processing files lacking user input validation. This may allow an attacker to access information and remotely execute arbitrary code.CVE-2019-13541 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calcul...
[]
null
null
7.8
null
ICSA-20-353-01
Treck TCP/IP Stack (Update A)
A vulnerability in Treck HTTP Server components allow an attacker to cause a denial-of-service condition. This vulnerability may also result in arbitrary code execution.CVE-2020-25066 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N...
[]
null
null
3.7
null
ICSA-22-286-12
Siemens APOGEE, TALON and Desigo PXC/PXM Products
The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.
[]
null
7.5
null
null
ICSA-22-286-07
Siemens Nucleus RTOS FTP Server
The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server. CVE-2022-38371 has been assigned to this vulner...
[]
null
7.5
null
null
ICSA-20-245-01
Mitsubishi Electric Multiple Products (Update G)
The affected products are vulnerable to impersonation of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
[]
null
null
7.3
null
ICSA-20-014-03
Siemens SCALANCE X Switches (Update B)
Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an at...
[]
null
8.8
null
null
ICSA-19-043-04
Siemens SIMATIC S7-300 CPU
The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of ...
[]
null
7.5
null
null
ICSMA-19-080-01
Medtronic Conexus Radio Frequency Telemetry Protocol (Update C)
The Conexus telemetry protocol utilized within this ecosystem does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product 's radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communicati...
[]
null
null
6.5
null
ICSA-22-011-01
Johnson Controls VideoEdge
The affected product is susceptible to a vulnerability scan, which may cause a denial-of-service condition.CVE-2021-36199 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
[]
null
null
5.3
null
ICSA-20-287-04
Fieldcomm Group HART-IP and hipserver
A malicious attacker could exploit this interface by constructing HART-IP messages with sufficiently large payloads to overflow the internal buffer and crash the device, or obtain control of the device.CVE-2020-16209 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vect...
[]
null
null
9.8
null
ICSA-22-167-03
AutomationDirect DirectLOGIC with Ethernet
A specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition.CVE-2022-2004 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H...
[]
null
null
7.5
null
ICSA-21-287-04
Siemens SINUMERIK
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.
[]
null
7.5
null
null
ICSA-23-136-03
Rockwell Automation FactoryTalk Vantagepoint
The affected product is vulnerable to a cross site request forgery attack that may allow an attacker to impersonate a legitimate user. CVE-2023-2444 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H).
[]
null
null
7.1
null
ICSA-21-077-03
Hitachi ABB Power Grids eSOMS Telerik
Path traversal in RadChart in Telerik UI for ASP.NET AJAX allows a remote attacker to read and delete an image with extension .BMP, .EXIF, .GIF, .ICON, .JPEG, .PNG, .TIFF, or .WMF on the server through a specially crafted request.CVE-2019-19790 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has be...
[]
null
null
4.3
null
ICSA-21-075-03
Hitachi ABB Power Grids AFS Series
A crafted HSR frame can cause a denial-of-service condition on one of the ports in a HSR ring.CVE-2020-9307 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
6.5
null
ICSA-19-155-03
Geutebrück G-Cam and G-Code
A cross-site scripting vulnerability allows a remote authenticated attacker with access to event configuration to store malicious code on the server, which could later be triggered by a legitimate user resulting in code execution within the user 's browser.CVE-2019-10957 has been assigned to this vulnerability. A CVSS ...
[]
null
null
7.2
null
ICSA-22-333-03
Hitachi Energy MicroSCADA Pro/X SYS600 Products (Update A)
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. An authenticated user could launch an administrator level remote code execution regardless of the authenticated user's role.
[]
null
8.8
null
null
ICSA-21-119-02
Cassia Networks Access Controller
An attacker may be able to use minify route with a relative path to view any file on the server.CVE-2021-22685 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
[]
null
null
6.2
null
ICSA-23-012-09
Siemens Mendix SAML Module
The affected module is vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link.
[]
null
9.3
null
null
ICSA-20-261-01
Advantech WebAccess Node
The affected product has incorrect permissions set for resources used by specific services, which may allow code execution with system privileges.CVE-2020-16202 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSMA-20-023-01
GE CARESCAPE, ApexPro, and Clinical Information Center systems
A vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.CVE-2020-6961 has been assigned to this vulnerability. A CVSS v3 base score of 10 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). To see how t...
[]
null
null
10
null
ICSA-23-075-03
Siemens RUGGEDCOM CROSSBOW V5.2
The client query handler of the affected application fails to check for proper permissions for specific write queries. This could allow an authenticated remote attacker to perform unauthorized actions. The client query handler of the affected application fails to check for proper permissions when assigning groups to us...
[]
null
6.6
null
null
ICSA-23-164-02
Rockwell Automation FactoryTalk Services Platform
Hard-coded cryptographic key vulnerabilities could lead to privilege escalation. FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies. This vulnerability could allow a local authenticated non-admin user to generate an invalid administrator cookie giving them administrative p...
[]
null
null
4.1
null
ICSA-22-209-01
Rockwell Products Impacted by Chromium Type Confusion
Rockwell Automation has been made aware of a third-party vulnerability present in multiple vendor components currently in use. Due to how Rockwell Automation uses the Chromium web browser, exploitation of this vulnerability may cause the affected products to become temporarily unavailable. As a result, the CVSS Score w...
[]
null
null
4
null
ICSA-22-342-03
Rockwell Automation Logix controllers
An unauthorized user could use a specially crafted sequence of Ethernet and IP messages and combine them with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers, resulting in a denial-of-service condition. If the target device becomes unavailable in this condition, a u...
[]
null
null
8.6
null
ICSA-22-286-03
Siemens Solid Edge
The affected application contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17627)
[]
null
7.8
null
null
ICSMA-19-297-01
Philips IntelliSpace Perinatal
A vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to break-out from the containment of the application and access unauthorized resources from t...
[]
null
null
6.1
null
ICSA-22-109-05
Elcomplus SmartPTT SCADA Server
An authenticated attacker can inject arbitrary JavaScript into critical parameters.CVE-2021-43932 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An unauthenticated user can request various files from the server w...
[]
null
null
7.6
null
ICSA-21-012-04
Siemens Solid Edge
Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supp...
[]
null
7.8
null
null
ICSA-22-102-02
Mitsubishi Electric MELSEC-Q Series C Controller Module
The affected product uses a vulnerable version of Wind River VxWorks that could result in a heap-based buffer overflow in the DHCP clientCVE-2021-29998 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H).
[]
null
null
9
null
ICSA-21-222-02
Siemens Automation License Manager
Sending specially crafted packets to port 4410/tcp of an affected system could lead to extensive memory being consumed and as such could cause a denial-of-service preventing legitimate users from using the system.
[]
null
5.9
null
null
ICSA-22-013-01
Mitsubishi Electric MELSEC-F Series
The affected product is vulnerable due to a lack of administrative controls, which may allow an attacker to remotely send specially crafted packets and cause a denial-of-service condition or other unspecified effects.CVE-2021-20612 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; ...
[]
null
null
7.5
null
ICSA-21-131-13
Siemens SINAMICS Medium Voltage Products Telnet (Update A)
The Telnet service of the HMI Comfort Panels system component in affected SINAMICS products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default. CVE-2020-15798 has been assigned to this vulnerability. A CVSS v3 base sco...
[]
null
null
8.1
null
ICSA-19-099-06
Siemens SIMATIC, SIMOCODE, SINAMICS, SITOP, and TIM (Update I)
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to t...
[]
null
7.5
null
null
ICSA-21-236-02
Hitachi ABB Power Grids Retail Operations and CSB Products
An attacker who has gained access to an authorized user 's computer could exploit this vulnerability to access database credentials and gain read/edit access to application data.CVE-2021-35529 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been calculated; the CVSS vector string is (AV:N/AC:H/...
[]
null
null
7.7
null
ICSA-23-285-04
Siemens Xpedition Layout Browser
Affected application contains a stack overflow vulnerability when parsing a PCB file. An attacker can leverage this vulnerability to execute code in the context of the current process.
[]
null
7.8
null
null
ICSMA-18-235-01
BD Alaris Plus
The software does not perform authentication for functionality that requires a provable user identity.CVE-2018-14786 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H).
[]
null
null
9.4
null
ICSA-21-222-04
Siemens SINEC NMS
The affected application incorrectly neutralizes special elements when creating batch operations which could lead to command injection. An authenticated remote attacker with administrative privileges could exploit this vulnerability to execute arbitrary code on the system with system privileges.
[]
null
7.2
null
null
ICSA-20-086-01
Advantech WebAccess
A stack-based buffer overflow vulnerability caused by a lack of proper validation of the length of user-supplied data may allow remote code execution.CVE-2020-10607 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
8.8
null
ICSA-20-147-01
Inductive Automation Ignition (Update B)
The affected product lacks proper authentication required to query the server.CVE-2020-12004 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). The affected product lacks proper validation of user-supplied data, whic...
[]
null
null
5.3
null
ICSA-19-155-01
PHOENIX CONTACT PLCNext AXC F 2152
A remote attacker can exploit a server 's private key by sending carefully constructed UserIdentityTokens encrypted with the Basic128Rsa15 security policy. This could allow an attacker to decrypt passwords even if encrypted with another security policy such as Basic256Sha256. CVE-2018-7559 has been assigned to this vul...
[]
null
null
5.3
null
ICSA-17-353-05
WECON Technology Co., Ltd. LeviStudio HMI Editor
The heap-based buffer overflow vulnerability has been identified, which may allow remote code execution.CVE-2017-16717 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).
[]
null
null
7.3
null
ICSA-21-313-03
Siemens Nucleus RTOS TCP/IP Stack
ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004) The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a use...
[]
null
7.5
null
null
ICSA-19-227-04
Siemens SINAMICS (Update C)
The webserver of the affected devices contains a vulnerability that may lead to a denial-of-service condition. An attacker may cause a denial-of-service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the aff...
[]
null
7.5
null
null
ICSA-22-291-01
Advantech R-SeeNet
Advantech R-SeeNet Versions 2.4.19 and prior are vulnerable to path traversal attacks. An unauthorized attacker could remotely exploit vulnerable PHP code to delete .PDF files.CVE-2022-3387 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:...
[]
null
null
9.8
null
ICSMA-22-006-01
Philips Engage Software
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data.CVE-2021-23173 has been assigned to this vulnerability. A CVSS v3 base score of 2.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:N/A:N).
[]
null
null
2.6
null