id stringlengths 12 16 | title stringlengths 6 140 | description stringlengths 76 139k | cpes listlengths 0 0 | cvss_v4_0 null | cvss_v3_1 float64 2.5 10 ⌀ | cvss_v3_0 float64 1.9 10 ⌀ | cvss_v2_0 null |
|---|---|---|---|---|---|---|---|
ICSA-23-348-09 | Siemens Simantic S7-1500 CPU family | Affected devices improperly handle specially crafted packets sent to port 102/tcp.
This could allow an attacker to create a denial of service condition. A restart is needed to restore
normal operations. | [] | null | 7.5 | null | null |
ICSA-24-123-02 | Delta Electronics DIAEnergie | Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed. Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability tha... | [] | null | 8.8 | null | null |
ICSA-17-192-01 | Siemens SIMATIC Logon | Specially crafted packets sent to the SIMATIC Logon Remote Access service on Port 16389/TCP could cause a denial-of-service condition. The service restarts automatically.CVE-2017-9938 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S... | [] | null | null | 5.3 | null |
ICSA-23-059-01 | Hitachi Energy Gateway Station | A NULL pointer dereference was found in affected versions of OpenLDAP. An unauthenticated attacker could remotely crash the slapd process by sending a specially crafted request, causing a denial-of-service condition on the user authentication function. CVE-2020-25692 has been assigned to this vulnerability. A CVSS v3 b... | [] | null | null | 7.5 | null |
ICSA-20-343-06 | Siemens XHQ Operations Intelligence | The application's web server could expose non-sensitive information about the server's architecture. This could allow an attacker to adapt further attacks to the version in place. The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing t... | [] | null | 8.1 | null | null |
ICSA-25-007-02 | Nedap Librix Ecoreader | The affected product is missing authentication for critical functions that could allow an unauthenticated attacker to potentially execute malicious code. | [] | null | 8.6 | null | null |
ICSA-24-081-01 | Advantech WebAccess/SCADA | There is a SQL Injection vulnerability in Advantech's WebAccess/SCDA software that allows an authenticated attacker to remotely inject SQL code on the database. Successful exploitation of this vulnerability could allow an attacker to read or modify data on the remote database. | [] | null | 6.4 | null | null |
ICSA-19-141-01 | Computrols CBAS Web | Users can perform certain actions via HTTP requests without performing any validity checks, which may allow unauthorized actions with administrative privileges if a logged-in user visits a malicious website.CVE-2019-10847 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS... | [] | null | null | 5.3 | null |
ICSA-20-303-01 | Mitsubishi Electric MELSEC iQ-R, Q, and L Series (Update D) | Mitsubishi Electric MELSEC iQ-R, Q, and L Series CPU modules are vulnerable to uncontrolled resource consumption. When the CPU module receives a specially crafted packet from a malicious attacker, Ethernet communication may enter a denial-of-service condition and a reset is required to recover it. | [] | null | 7.5 | null | null |
ICSA-23-206-02 | Rockwell Automation ThinManager ThinServer | An executable used in the affected products can be configured to enable an API feature in the HTTPS server settings. This feature is disabled by default. When the API is enabled and handling requests, a path traversal vulnerability exists that could allow a remote actor to leverage the server's file system privileges a... | [] | null | null | 7.5 | null |
ICSA-23-026-04 | Sierra Wireless AirLink Router with ALEOS Software | AirLink router versions with ALEOS software are vulnerable when users with valid ACEManager credentials and access to the ACEManager interface could manipulate the IP logging operation to execute arbitrary shell commands on the device.-CVE-2022-46649 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 ... | [] | null | null | 4.5 | null |
ICSA-23-040-03 | Johnson Controls System Configuration Tool (SCT) | System Configuration Tool (SCT) versions 14 and 15 are vulnerable during a cross-site scripting attack. This could allow an attacker to access cookies and take control of an affected system.-CVE-2022-21939 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string i... | [] | null | null | 7.5 | null |
ICSMA-17-227-01 | ICSMA-17-227-01_BMC Medical and 3B Medical Luna CPAP Machine | An improper input validation vulnerability has been identified, which may allow an authenticated attacker to crash the CPAP 's Wi-Fi module resulting in a denial-of-service condition. | [] | null | null | 4.6 | null |
ICSA-22-242-01 | Hitachi Energy FACTS Control Platform (FCP) Product | Hitachi Energy is aware of public reports of multiple vulnerabilities in open-source software components (OpenSSL and Node.JS) used in the FACTS Control Platform (FCP) product. Versions are available to remediate the identified vulnerabilities.CVE-2020-1968, CVE-2020-8172, CVE-2020-8174, CVE-2020-8201, CVE-2020-8252, C... | [] | null | null | 8.1 | null |
ICSA-17-150-01 | Automated Logic Corporation ALC WebCTRL, Liebert SiteScan, Carrier i-VU | An attacker could enter malicious input to WebCTRL, i-Vu, or SiteScan Web through a weakly configured XML parser causing the application to execute arbitrary code or disclose file contents from a server or connected network.CVE-2016-5795 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assi... | [] | null | null | 6.5 | null |
ICSA-22-347-03 | Contec CONPROSYS HMI System (CHS) | CONPROSYS HMI System versions 3.4.4 and prior are vulnerable to an OS Command Injection, which could allow an unauthenticated remote attacker to send specially crafted requests that could execute commands on the server. CVE-2022-44456 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been assign... | [] | null | null | 7.5 | null |
ICSA-24-165-17 | Rockwell Automation FactoryTalk View SE | A privilege escalation vulnerability exists in FactoryTalk View SE. The vulnerability allows low-privilege users to edit scripts, bypassing Access Control Lists, and potentially gaining further access within the system. | [] | null | 7.8 | null | null |
ICSA-21-168-03 | Advantech WebAccess/SCADA (Update A) | The affected product is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage.CVE-2021-32956 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR... | [] | null | null | 6.5 | null |
ICSA-17-353-05 | WECON Technology Co., Ltd. LeviStudio HMI Editor | The heap-based buffer overflow vulnerability has been identified, which may allow remote code execution.CVE-2017-16717 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). | [] | null | null | 7.3 | null |
ICSA-18-254-02 | Fuji Electric V-Server Lite | A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code.CVE-2018-10637 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-21-042-02 | Rockwell Automation DriveTools SP and Drives AOP | DriveTools and Drives AOP both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system.CVE-2021-22665 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string... | [] | null | null | 7.5 | null |
ICSA-21-056-04 | ProSoft Technology ICX35 | Changing the password on the module webpage does not require the user to type in the current password first. Thus, the password could be changed by a user or external process without knowledge of the current password.CVE-2021-22661 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated... | [] | null | null | 8.2 | null |
ICSA-21-189-01 | Rockwell Automation MicroLogix 1100 | A remote, unauthenticated attacker sending specially crafted commands could cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault when the controller is switched to RUN mode.CVE... | [] | null | null | 8.6 | null |
ICSMA-18-107-01 | Abbott Laboratories Defibrillator | The device 's authentication algorithm, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the ICD or CRT-D via RF communications.CVE-2017-12712 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has ... | [] | null | null | 5.3 | null |
ICSA-17-117-01B | GE Multilin SR, UR, and URplus Protective Relays (Update B) | Cipher text versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Cipher text of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.CVE-2017-7905 has been assigned to this vulnerability... | [] | null | null | 8.1 | null |
ICSA-22-195-13 | Siemens Mendix | In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords. | [] | null | 4.9 | null | null |
ICSA-23-194-06 | Honeywell Experion PKS, LX and PlantCruise | Experion Server or Console Station could experience a denial-of-service condition due to a heap overflow during the handling of a specially crafted message for a specific configuration operation. Experion Server or Console Station could experience a denial-of-service condition or remote code execution due to a stack o... | [] | null | null | 9.8 | null |
ICSMA-17-017-02 | BD Alaris 8015 PC Unit (Update B) | An unauthorized user with physical access to an Alaris 8015 PC unit may be able to obtain unencrypted wireless network authentication credentials and other sensitive technical data by removing the external Wi-Fi card from an Alaris 8015 PC unit and connecting a pre-programmed malicious CF (CompactFlash) card to perform... | [] | null | null | 6.8 | null |
ICSA-22-286-03 | Siemens Solid Edge | The affected application contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17627) | [] | null | 7.8 | null | null |
ICSA-20-289-01 | Advantech WebAccess/SCADA | The WADashboard component of WebAccess/SCADA may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.CVE-2020-25161 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/... | [] | null | null | 8.8 | null |
ICSA-24-226-06 | Rockwell Automation FactoryTalk View Site Edition | A code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions. | [] | null | 8.8 | null | null |
ICSA-18-158-01 | Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway | An unquoted search path or element may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.CVE-2018-10619 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector st... | [] | null | null | 8.8 | null |
ICSA-18-317-04 | Siemens SCALANCE S | The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this... | [] | null | null | 4.7 | null |
ICSA-23-101-01 | FANUC ROBOGUIDE-HandlingPRO | FANUC ROBOGUIDE-HandlingPRO Versions 9 Rev.ZD and prior is vulnerable to a path traversal, which could allow an attacker to remotely read files on the system running the affected software. CVE-2023-1864 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been assigned; the CVSS vector string is (AV... | [] | null | null | 6.8 | null |
ICSA-19-192-03 | Siemens TIA Administrator (TIA Portal) | The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker... | [] | null | null | 8 | null |
ICSA-18-144-01 | Schneider Electric Floating License Manager | OpenSSL incorrectly uses pointer arithmetic for heap-buffer boundary checks, which may allow denial of service attacks or other unspecified behavior.CVE-2016-2177 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Th... | [] | null | null | 6.1 | null |
ICSA-23-348-02 | Johnson Controls Kantech Gen1 ioSmart | Kantech Gen1 ioSmart card readers with firmware versions prior to 1.7.2 do not properly release memory after its effective lifetime. An attacker with physical access to the Kantech Gen1 ioSmart card reader in certain circumstances can recover the reader's communication memory between the card and reader. CWE-200: Expos... | [] | null | 7.5 | null | null |
ICSA-22-249-02 | AVEVA Edge 2020 R2 SP1 and all prior versions | The scripting capability provided by AVEVA Edge is unrestricted; a user could abuse this to achieve arbitrary code execution.CVE-2022-36970 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A vulnerability exists in... | [] | null | null | 6.6 | null |
ICSA-18-352-05 | Siemens TIM 1531 IRC Modules | The device was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no ... | [] | null | 10 | null | null |
ICSA-22-356-04 | Omron CX-Programmer | CX-Programmer is vulnerable to a Out-of-bounds Write when a user opens a specially crafted CXP file. This could cause a loss of sensitive information or arbitrary code execution.CVE-2022-43509 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR... | [] | null | null | 7.8 | null |
ICSMA-18-156-01 | Philips' IntelliVue Patient and Avalon Fetal Monitors | The vulnerability allows an unauthenticated attacker to access memory (write-what-where) from an attacker-chosen device address within the same subnet.CVE-2018-10597 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H).... | [] | null | null | 8.2 | null |
ICSA-22-195-15 | Siemens SIMATIC eaSie Core Package | The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow a remote attacker to trigger a denial of service of the affected system. The underlying MQTT service of affected systems does not perform authentication in the default configuration. This could... | [] | null | 10 | null | null |
ICSA-21-252-03 | Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU | The affected product allows an attacker to execute arbitrary commands due to the passing of unsafe user supplied data to the system shell.CVE-2019-14931 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). It is possib... | [] | null | null | 6.5 | null |
ICSA-20-105-03 | Triangle MicroWorks SCADA Data Gateway | This vulnerability allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.CVE-2020-10615 has been assigned to this vulnerabi... | [] | null | null | 9.8 | null |
ICSMA-21-175-01 | Philips Interoperability Solution XDS | The affected product is vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an attacker to remotely read LDAP system credentials.CVE-2021-32966 has been assigned to this vulnerability. A CVSS v3 base s... | [] | null | null | 3.7 | null |
ICSA-24-354-03 | Delta Electronics DTM Soft | The affected product deserializes objects, which could allow an attacker to execute arbitrary code. | [] | null | 7.8 | null | null |
ICSA-18-352-01 | ABB GATE-E2 | These devices do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.CVE-2018-18995 has been assigned to this vulnera... | [] | null | null | 7.1 | null |
ICSA-23-193-01 | Rockwell Automation Select Communication Modules | Where this vulnerability exists in the 1756 EN2* and 1756 EN3* products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device. Where this... | [] | null | null | 7.5 | null |
ICSA-21-208-01 | KUKA KR C4 | An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials.CVE-2021-33016 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An attacker can gain VxWorks Shell after login... | [] | null | null | 8.8 | null |
ICSA-22-277-01 | Johnson Controls Metasys ADX Server | The affected product software does not prove or insufficiently validates user identity claims.CVE-2022-21936 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H). | [] | null | null | 8.1 | null |
ICSA-23-033-05 | Delta Electronics DX-2100-L1-CN | The web configuration service of the affected device contains an authenticated command injection vulnerability. It can be used to execute system commands on the operating system (OS) from the device in the context of the user "root." If the attacker has credentials for the web service, then the device could be fully co... | [] | null | 9 | null | null |
ICSA-23-075-04 | Siemens SCALANCE W1750D Devices | A timing based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulne... | [] | null | 7.4 | null | null |
ICSA-23-208-03 | Mitsubishi Electric CNC Series (Update E) | In Mitsubishi Electric CNC series devices, a malicious remote attacker could cause a denial-of-service condition and execute malicious code by sending specially crafted packets. | [] | null | null | 9.8 | null |
ICSA-21-287-06 | Siemens Solid Edge | The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process. The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user s... | [] | null | 7.8 | null | null |
ICSA-23-215-02 | Mitsubishi Electric GT and GOT Series Products | Information disclosure vulnerability exists in the Data Transfer Security function on GT Designer3, GOT2000 Series, GOT SIMPLE Series and GT SoftGOT2000. This vulnerability allows an attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords. | [] | null | null | 7.5 | null |
ICSA-23-096-06 | mySCADA myPRO | mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands. CVE-2023-28400 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). mySCAD... | [] | null | null | 9.9 | null |
ICSA-22-223-03 | Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70 | A memory corruption vulnerability exists in the XML-parsing ParseAttribs functionality of AT&T Labs ' Xmill 0.7. A specially crafted XML file can lead to a heap buffer overflow. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21810 has been assigned to this vulnerability. A CVSS v3 base ... | [] | null | null | 9.8 | null |
ICSA-20-287-02 | LCDS LAquis SCADA | An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the application due to an out-of-bounds read vulnerability.CVE-2020-25188 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string... | [] | null | null | 7.8 | null |
ICSA-23-339-01 | Zebra ZTC Industrial ZT400 and ZTC Desktop GK420d | A vulnerability of authentication bypass has been found in Zebra Technologies ZTC Industrial ZT410 and ZTC Desktop GK420d. This vulnerability allows an attacker that is in the same network as the printer to change the username and password for the web page by sending a specially crafted POST request to the setvarsResul... | [] | null | null | 5.4 | null |
ICSA-22-298-04 | Hitachi Energy MicroSCADA X DMS600 | A vulnerability exists when Hitachi Energy MicroSCADA X DMS600 v4.5 uses an affected version of PostgreSQL. While modifying certain SQL array values, missing bounds checks let authenticated database users write arbitrary bytes to a wide area of server memory. Successful exploitation of this vulnerability could allow at... | [] | null | null | 6.5 | null |
ICSA-19-311-01 | Mitsubishi Electric MELSEC-Q Series and MELSEC-L Series CPU Modules | A remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.CVE-2019-13555 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV... | [] | null | null | 7.5 | null |
ICSA-17-222-04 | Fuji Electric Monitouch V-SFT | The stack-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution.CVE-2017-9659 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). A heap-based buffer overflow vu... | [] | null | null | 4.5 | null |
ICSA-24-226-03 | Rockwell Automation GuardLogix/ControlLogix 5580 Controller | A denial-of-service vulnerability exists in the affected products. The vulnerability occurs when a malformed CIP packet is sent over the network to the device and results in a major nonrecoverable fault causing a denial-of-service. | [] | null | 7.5 | null | null |
ICSA-21-236-01 | Hitachi ABB Power Grids TropOS | The 802.11 standard that underpins Wi-Fi protected access (WPA, WPA2, and WPA3) and wired equivalent privacy (WEP) does not require received fragments be cleared from memory after (re)connecting to a network. Under the right circumstances, when another device sends fragmented frames encrypted using WEP, CCMP, or GCMP, ... | [] | null | null | 5.4 | null |
ICSA-21-110-04 | Delta Electronics CNCSoft ScreenEditor | The affected product is vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.CVE-2021-22668 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-21-005-05 | Delta Electronics DOPSoft | The affected product is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.CVE-2020-27275 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The a... | [] | null | null | 7.8 | null |
ICSA-21-350-07 | Siemens POWER METER SICAM Q100 | The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution. | [] | null | 9.1 | null | null |
ICSA-24-074-12 | Delta Electronics DIAEnergie | Privileges are not fully verified server-side, which can be abused by a user with limited privileges to bypass authorization and access privileged functionality SQL injection vulnerability exists in the script Handler_CFG.ashx. SQL injection vulnerability exists in the script DIAE_tagHandler.ashx. SQL injection vulnera... | [] | null | 4.6 | null | null |
ICSA-22-300-01 | Rockwell Automation FactoryTalk Alarm and Events Server | An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.CVE-2022-38744 has been assigne... | [] | null | null | 7.5 | null |
ICSA-22-032-02 | Advantech ADAM-3600 | The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.CVE-2022-22987 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/... | [] | null | null | 9.8 | null |
ICSA-21-040-10 | Siemens DIGSI 4 | Several folders in the %PATH% are writeable by normal users. As these folders are included in the search for dlls, an attacker could place dlls there with code executed by SYSTEM. | [] | null | 7.8 | null | null |
ICSA-20-042-04 | Siemens PROFINET-IO Stack (Update H) | Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit
internal resource allocation when multiple legitimate diagnostic package
requests are sent to the DCE-RPC interface.
This could lead to a denial of service condition due to lack of memory
for devices that include a vulnerable version of the stack.
Th... | [] | null | 7.5 | null | null |
ICSA-19-120-01 | ICSA-19-120-01_Rockwell Automation CompactLogix 5370 | An attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering the system.CVE-2019-10952 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 ha... | [] | null | null | 8.6 | null |
ICSA-21-180-04 | JTEKT TOYOPUC PLC | When the affected products receive an invalid frame, the outside area of a receive buffer for FL-net are overwritten. As a result, the PLC CPU detects a system error, and the affected products stop.CVE-2021-27477 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector s... | [] | null | null | 6.5 | null |
ICSA-18-123-01 | Lantech IDS 2102 | Nearly all input fields allow for arbitrary input on the device.CVE-2018-8869 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A stack-based buffer overflow vulnerability has been identified which may allow remote ... | [] | null | null | 9.8 | null |
ICSA-23-131-14 | Rockwell Automation PanelView 800 | The affected product is vulnerable to an out-of-bounds write, which could allow an attacker to accomplish a heap buffer overflow if the user has the email feature enabled in the project file WolfSSL uses. This feature is disabled by default. CVE-2020-36177 has been assigned to this vulnerability. A CVSS v3 base score o... | [] | null | 7.8 | null | null |
ICSMA-17-250-02A | Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A) | A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017... | [] | null | null | 3.7 | null |
ICSA-19-164-02 | WAGO Industrial Managed Switches 852-303, 852-1305, and 852-1505 | An attacker with access to the hard-coded credentials may gain access to the operating system of the managed switch with root privileges, which may allow manipulation of the operating system of the managed switch.CVE-2019-12550 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the ... | [] | null | null | 9.8 | null |
ICSA-23-131-09 | Rockwell Automation Kinetix 5500 | Rockwell Automation Kinetix 5500 devices manufactured between May 2022 and January 2023 running Version 7.13 have telnet and file transfer protocol (FTP) ports open by default. This could allow an attacker access to the device. CVE-2023-1834 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been ... | [] | null | 9.4 | null | null |
ICSA-21-131-12 | Siemens SIMATIC SmartVNC HMI WinCC Products (Update B) | SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition. SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the ser... | [] | null | 7.5 | null | null |
ICSA-21-110-05 | Delta Electronics CNCSoft-B | The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.CVE-2021-22660 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The affected product is vulnerable ... | [] | null | null | 7.8 | null |
ICSA-22-088-01 | Rockwell Automation ISaGRAF | When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality. CVE-2022-... | [] | null | null | 5.5 | null |
ICSMA-22-251-01 | Baxter Sigma Spectrum Infusion Pump (Update A) | The Baxter Spectrum WBM (v16, v16D38, v17, v17D19, v20D29 to v20D32, and v22D19 to v22D28) stores network credentials and patient health information (PHI) in unencrypted form. PHI is only stored in Spectrum IQ pumps using auto programming. An attacker with physical access to a device without all data and settings erase... | [] | null | null | 7.5 | null |
ICSA-24-354-03 | Delta Electronics DTM Soft | The affected product deserializes objects, which could allow an attacker to execute arbitrary code. | [] | null | 7.8 | null | null |
ICSA-22-055-03 | Schneider Electric Easergy P5 and P3 | If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to this product, they could observe and manipulate traffic associated with product configuration. This could result in information disclosure. CVE-2022-22722 has been assigned to thi... | [] | null | null | 5.1 | null |
ICSA-23-348-07 | Siemens SIMATIC STEP 7 (TIA Portal) | An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application. | [] | null | 4.2 | null | null |
ICSA-17-283-02 | JanTek JTC-200 | An attacker could perform actions with the same permissions as a victim user, provided the victim has an active session and is induced to trigger the malicious request.CVE-2016-5789 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U... | [] | null | null | 9.8 | null |
ICSA-23-348-12 | Siemens SCALANCE and RUGGEDCOM M-800/S615 Family | Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device. An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the ... | [] | null | 7.2 | null | null |
ICSA-24-074-11 | Siemens RUGGEDCOM APE1808 with Fortigate NGFW Devices | An improper certificate validation vulnerability [CWE-295] in FortiOS 7.2.0 through 7.2.3, 7.0.0 through 7.0.7, 6.4 all versions, 6.2 all versions, 6.0 all versions and FortiProxy 7.0.0 through 7.0.6, 2.0 all versions, 1.2 all versions may allow a remote and unauthenticated attacker to perform a Man-in-the-Middle attac... | [] | null | 8.1 | null | null |
ICSA-20-044-02 | Schneider Electric Magelis HMI Panels | When the device receives a high rate of frames, the HMI may temporarily freeze. When the attack stops, the buffered commands are processed by the HMI.CVE-2019-6833 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:N/A:H). | [] | null | null | 7.4 | null |
ICSA-21-159-11 | Siemens SIMATIC NET CP 443-1 OPC UA | The rate limiting feature in NTP 4.x before 4.2.8p4 and 4.3.x before 4.3.77 allows remote attackers to have unspecified impact via a large number of crafted requests. The datalen parameter in the refclock driver in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to execute arbitrary code or ca... | [] | null | 8.8 | null | null |
ICSA-21-103-13 | Siemens SIMOTICS CONNECT 400 (Update A) | The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denia... | [] | null | 5.3 | null | null |
ICSA-23-306-02 | Mitsubishi Electric MELSEC iQ-F/iQ-R Series CPU Module (Update A) | A denial-of-service vulnerability exists in the web server function of the MELSEC iQ-F/iQ-R Series CPU module, which could allow an attacker to prevent legitimate users from logging in to the web server function for a certain period of time. The impact of this vulnerability will persist while the attacker continues to ... | [] | null | 5.3 | null | null |
ICSA-24-228-01 | Siemens SCALANCE M-800, RUGGEDCOM RM1224 | Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again. Affected devices do not properly ... | [] | null | 6.5 | null | null |
ICSA-17-054-03 | Schneider Electric Modicon M340 PLC (Update A) | A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.CVE-2017-6017 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-19-213-03 | 3S-Smart Software Solutions GmbH CODESYS V3 | The CODESYS Gateway does not correctly verify the ownership of a communication channel. CVE-2019-9010 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H). A crafted communication request may cause uncontrolled memory all... | [] | null | null | 7.5 | null |
ICSA-23-108-01 | Omron CS/CJ Series | Omron CS/CJ series programmable logic controllers are missing authentication for the file system. This could allow an attacker to access the file system (via memory card or EM file memory) and obtain all available sensitive information. CVE-2022-45794 has been assigned to this vulnerability. A CVSS v3 base score of 7... | [] | null | null | 7.5 | null |
ICSA-23-192-03 | Panasonic Control FPWin Pro7 | In Panasonic Control FPWIN versions 7.6.0.3 and prior, a stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or a parameter to a function). Panasonic Control FPWIN versions 7.6.0.3 and prior allocates or initializes a resource such... | [] | null | null | 7.8 | null |
ICSA-23-166-08 | Siemens SIMATIC STEP 7 and Derived Products | The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.
An attacker with network access to the server network could leverage these embedded functions to run cod... | [] | null | 9.9 | null | null |
ICSA-19-337-02 | Moxa AWK-3121 | The device uses HTTP traffic by default allowing insecure communication to the web server, which could allow an attacker to compromise sensitive data such as credentials.CVE-2018-10690 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:... | [] | null | null | 8.8 | null |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.