id
stringlengths
12
16
title
stringlengths
6
140
description
stringlengths
76
139k
cpes
listlengths
0
0
cvss_v4_0
null
cvss_v3_1
float64
2.5
10
cvss_v3_0
float64
1.9
10
cvss_v2_0
null
ICSA-21-159-03
AVEVA InTouch
The vulnerability could expose cleartext credentials from InTouch Runtime (WindowViewer) if an authorized, privileged user creates a diagnostic memory dump of the process and saves it to a non-protected location.CVE-2021-32942 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the...
[]
null
null
6.6
null
ICSA-21-355-04
Emerson DeltaV
A specially crafted script could cause a controller to restart and cause a denial-of-service condition.CVE-2021-26264 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H). Missing DLLs, if replaced by an insider, could ...
[]
null
null
8.1
null
ICSA-22-349-11
Siemens SIPROTEC 5 Devices
A buffer overrun can be triggered in X.509 certificate verification, specifically in name constraint checking. Note that this occurs after certificate chain signature verification and requires either a CA to have signed the malicious certificate or for the application to continue certificate verification despite failur...
[]
null
7.5
null
null
ICSMA-17-215-01
ICSMA-17-215-01_Siemens Molecular Imaging Vulnerabilities
An unauthenticated remote attacker could execute arbitrary code via a specially crafted remote procedure call (RPC) request sent to the server service of affected Microsoft Windows systems. An unauthenticated remote attacker could execute arbitrary code with the permissions of the web server by sending a specially craf...
[]
null
null
9.8
null
ICSA-20-303-01
Mitsubishi Electric MELSEC iQ-R, Q, and L Series (Update D)
Mitsubishi Electric MELSEC iQ-R, Q, and L Series CPU modules are vulnerable to uncontrolled resource consumption. When the CPU module receives a specially crafted packet from a malicious attacker, Ethernet communication may enter a denial-of-service condition and a reset is required to recover it.
[]
null
7.5
null
null
ICSA-19-246-01
EZAutomation EZ Touch Editor
An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application.CVE-2019-13518 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-21-103-02
Advantech WebAccessSCADA
Incorrect permissions are set to default on the -Project Management ' page of WebAccess/SCADA portal, which may allow a low-privileged user to update an administrator 's password and login as an administrator to escalate privileges on the system.CVE-2021-22669 has been assigned to this vulnerability. A CVSS v3 base sco...
[]
null
null
8.8
null
ICSA-22-342-01
Advantech iView
Advantech iView versions 5.7.04.6469 and prior are vulnerable to a SQL injection that could disclose sensitive product information to an unauthorized user.CVE-2022-3323 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:...
[]
null
null
7.5
null
ICSA-24-011-08
Siemens SICAM A8000
The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps. By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands tha...
[]
null
6.6
null
null
ICSA-20-105-09
Siemens TIM 3V-IE and 4R-IE Family Devices
The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to e...
[]
null
9
null
null
ICSA-20-142-01
Johnson Controls Software House C-CURE 9000 and American Dynamics victor VMS
During installation or upgrade to C•CURE 9000 v2.70 and victor Video Management System v5.2, the credentials of the user performing the installation or upgrade are saved in a file. The install log file persists after the installation.CVE-2020-9045 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has...
[]
null
null
9.9
null
ICSA-18-114-02
Intel 2G Modem
Buffer overflow in ETWS processing module allows a remote attacker to potentially execute arbitrary code via an adjacent network.CVE-2018-3624 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:L).
[]
null
null
8.2
null
ICSA-18-025-01
Nari PCS-9611 (Update A)
An improper input validation vulnerability has been identified that affects a service within the software that may allow a remote attacker to arbitrarily read/access system resources and affect the availability of the system. CVE-2018-5447 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been ca...
[]
null
null
9.8
null
ICSA-19-192-02
Siemens SIMATIC WinCC and PCS7 (Update C)
The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerabili...
[]
null
null
7.2
null
ICSA-22-286-08
Siemens TCP Event Service of SCALANCE And RUGGEDCOM Devices
Affected devices with TCP Event service enabled do not properly handle malformed packets. This could allow an unauthenticated remote attacker to cause a denial of service condition and reboot the device thus possibly affecting other network resources.
[]
null
8.6
null
null
ICSA-19-213-02
Fuji Electric FRENIC Loader
The affected product is vulnerable to an out-of-bounds read vulnerability, which may allow an attacker to read limited information from the device.CVE-2019-13512 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L).
[]
null
null
4.4
null
ICSA-19-029-02
Mitsubishi Electric MELSEC-Q Series PLCs
A remote attacker can send specific packets over several ports on the affected products that will result in an Ethernet communication crash.
[]
null
null
7.5
null
ICSA-20-042-09
Siemens OZW Web Server
Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application's export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior a...
[]
null
5.3
null
null
ICSA-22-286-12
Siemens APOGEE, TALON and Desigo PXC/PXM Products
The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.
[]
null
7.5
null
null
ICSA-18-011-01
WECON Technology Co., Ltd. LeviStudio HMI Editor
Specially-crafted malicious files may be able to cause stack-based buffer overflow vulnerabilities, which may allow remote code execution. CVE-2017-16739 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L). A specially...
[]
null
null
5.3
null
ICSA-23-271-01
Rockwell Automation PanelView 800
An input/output validation vulnerability exists in a third-party component that the PanelView 800 utilizes. Libpng, which is PNG's reference library, version 1.6.32 and earlier does not properly check the length of chunks against the user limit. Libpng versions prior to 1.6.32 are susceptible to a vulnerability which, ...
[]
null
null
9.8
null
ICSA-17-283-01
LAVA Computer MFG Inc. Ether-Serial Link
An improper authentication vulnerability has been identified, which, if exploited, would allow an attacker with the same IP address to bypass authentication by accessing a specific uniform resource locator.CVE-2017-14003 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS ve...
[]
null
null
8.1
null
ICSA-18-060-01
ICSA-18-060-01_Siemens SIMATIC, SIMOTION, and SINUMERIK (Update A)
Multiple buffer overflows could allow attackers to execute arbitrary code. Local access to the system is required to exploit this vulnerability. CVE-2017-5705, CVE-2017-5706, and CVE-2017-5707 have been assigned to these vulnerabilities. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:L/A...
[]
null
null
8.2
null
ICSA-23-285-02
Siemens SCALANCE W1750D
There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba's access point management protocol) UDP port (8211). Successful exploitation of these vulnerabilities result in the ability ...
[]
null
5.4
null
null
ICSA-21-334-04
Johnson Controls CEM Systems AC2000
The affected product has an off-by-one error vulnerability, which may allow an attacker to achieve super user access on the operating system.CVE-2021-3156 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-22-228-07
Sequi PortBloque S
The affected product has improper authentication issues which may allow an attacker to bypass the authentication process and gain user-level access to the device.CVE-2022-2662 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:H...
[]
null
null
9.9
null
ICSA-21-278-03
Moxa MXview Network Management Software
A path traversal vulnerability in the application may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.CVE-2021-38452 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:...
[]
null
null
10
null
ICSA-23-271-01
Rockwell Automation PanelView 800
An input/output validation vulnerability exists in a third-party component that the PanelView 800 utilizes. Libpng, which is PNG's reference library, version 1.6.32 and earlier does not properly check the length of chunks against the user limit. Libpng versions prior to 1.6.32 are susceptible to a vulnerability which, ...
[]
null
null
9.8
null
ICSA-21-035-02
Horner Automation Cscape
The affected application lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-22663 has been assigned to this vulnerability. A CVSS v3 base score of...
[]
null
null
7.8
null
ICSA-23-136-01
Snap One OvrC Cloud
In Snap One OVRC cloud platform, the Hub is a device that is used to centralize and manage nested devices connected to it. A vulnerability exists where an attacker can impersonate a hub and send device requests to claim already claimed devices. The OVRC cloud platform receives the requests but does not validate if the ...
[]
null
null
8.3
null
ICSA-23-355-01
FXC AE1021/AE1021PE
FXC AE1021/AE1021PE versions 2.0.9 and prior are vulnerable to a code injection that could allow an authenticated user to achieve remote code execution via NTP server settings.
[]
null
8
null
null
ICSA-19-248-01
Red Lion Controls Crimson
Multiple vulnerabilities can be exploited when a valid user opens a specially crafted, malicious input file that can reference memory after it has been freed.CVE-2019-10996 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:...
[]
null
null
6.5
null
ICSA-22-167-10
Siemens SCALANCE XM-400 and XR-500
The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF ...
[]
null
5.9
null
null
ICSA-18-290-01
Omron CX-Supervisor (Update A)
When processing project files and tampering with a specific byte, memory corruption may occur within a specific object.CVE-2018-17905 has been assigned to this vulnerability. A CVSS v3 base score of 4.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L). When processing project files a...
[]
null
null
7
null
ICSA-18-296-01
Advantech WebAccess
Several stack-based buffer overflow vulnerabilities have been identified, which may allow an attacker to execute arbitrary code.CVE-2018-14816 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A .dll component is su...
[]
null
null
9.8
null
ICSA-20-035-01
ICSA-20-035-01_AutomationDirect C-More Touch Panels
It is possible to unmask credentials and other sensitive information on unprotected project files, which may allow an attacker to remotely access the system and manipulate system configurations.CVE-2020-6969 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector strin...
[]
null
null
10
null
ICSA-23-017-01
GE Digital Proficy Historian
Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.-CVE-2022-46732 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An u...
[]
null
null
7.5
null
ICSA-18-317-07
Siemens SIMATIC IT Production Suite
An attacker with network access to the installation could bypass the application-level authentication. In order to exploit the vulnerability, an attacker must obtain network access to an affected installation and must obtain a valid username to the system. Successful exploitation requires no user privileges and no user...
[]
null
null
7.7
null
ICSA-22-109-04
Elcomplus SmartPTT SCADA
An attacker can inject JavaScript code into a specific parameter that can executed upon accessing the dashboard or the main page.CVE-2021-43932 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H). A low-authenticated u...
[]
null
null
4.9
null
ICSA-21-280-06
FATEK Automation WinProladder
A use after free vulnerability may be exploited when a valid user opens a malformed project file, which may allow arbitrary code execution.CVE-2021-38438 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The affecte...
[]
null
null
3.3
null
ICSA-24-030-03
Mitsubishi Electric MELSEC WS Series Ethernet Interface Module
An authentication bypass vulnerability exists in the MELSEC WS Series Ethernet Interface Modules. A remote unauthenticated attacker can bypass authentication by capture-replay attack and illegally login to the modules. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with t...
[]
null
5.9
null
null
ICSA-23-193-01
Rockwell Automation Select Communication Modules
Where this vulnerability exists in the 1756 EN2* and 1756 EN3* products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device. Where this...
[]
null
null
7.5
null
ICSMA-21-084-01
Philips Gemini PET/CT Family
The software stores sensitive information in a removable media device that does not have built-in access control.CVE-2021-27456 has been assigned to this vulnerability. A CVSS v3 base score of 2.4 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
2.4
null
ICSA-24-079-01
Franklin Fueling System EVO 550/5000
Franklin Fueling System EVO 550 and EVO 5000 are vulnerable to a Path Traversal vulnerability that could allow an attacker to access sensitive files on the system.
[]
null
7.5
null
null
ICSA-21-056-03
Rockwell Automation Logix Controllers (Update A)
Studio 5000 Logix Designer uses a key to verify Logix controllers are communicating with the affected Rockwell Automation products. The product is vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Logix controllers.CVE-2021-22681 has been assigned to this vuln...
[]
null
null
10
null
ICSA-20-191-02
Rockwell Automation Logix Designer Studio 5000
The affected product is vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program.CVE-2020-12025 has been assigned to this vulnerability. A CVSS v3 base score of 3.6 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:C/C:...
[]
null
null
3.6
null
ICSA-20-135-01
Opto 22 SoftPAC Project
Paths specified within the zip files used to update the SoftPAC firmware are not sanitized. As a result, an attacker with user privileges can gain arbitrary file write access with system access.CVE-2020-12042 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector strin...
[]
null
null
9.8
null
ICSA-21-336-02
Johnson Controls Entrapass
The affected product is vulnerable to an exposure of sensitive information to an unauthorized actor.CVE-2021-36198 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L).
[]
null
null
8.3
null
ICSA-19-302-01
PHOENIX CONTACT Automation Worx Software Suite
A manipulated PC Worx or Config+ project file could lead to arbitrary code execution due to insufficient input data validation.CVE-2019-16675 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-23-103-12
Siemens Polarion ALM
The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.
[]
null
5.9
null
null
ICSA-21-098-01
FATEK Automation WinProladder
The affected product is vulnerable to an integer underflow, which may cause an out-of-bounds write and allow an attacker to execute arbitrary code.CVE-2021-27486has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-24-165-16
Rockwell Automation FactoryTalk View SE
A user authentication vulnerability exists in FactoryTalk View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer's server to view an HMI project. This action is allowed without proper authentication verification.
[]
null
8.6
null
null
ICSA-23-047-05
Siemens SiPass integrated AC5102 / ACC-G2 and ACC-AP
Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges.
[]
null
7.8
null
null
ICSA-21-147-04
Siemens JT2Go and Teamcenter Visualization
Affected applications lack proper validation of user-supplied data when parsing ASM files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11899) Affected applications lack pr...
[]
null
7.8
null
null
ICSA-23-103-10
Siemens Industrial Products
The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product. The webserver of the affected products contains a vulnerability that may lead to a denial...
[]
null
7.5
null
null
ICSA-18-023-01
Advantech WebAccess/SCADA
An attacker has read access to files within the directory structure of the target device. CVE-2018-5445 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). WebAccess/SCADA does not properly sanitize its inputs for SQL...
[]
null
null
5.3
null
ICSA-23-262-01
Siemens SIMATIC PCS neo Administration Console
The affected application leaks Windows admin credentials. An attacker with local access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems.
[]
null
5.5
null
null
ICSA-22-349-17
Siemens Mendix Email Connector
Affected versions of the module improperly handle access control for some module entities. This could allow authenticated remote attackers to read and manipulate sensitive information.
[]
null
8.1
null
null
ICSA-24-030-07
Rockwell Automation LP30/40/50 and BM40 Operator Interface
After successful authentication, specifically crafted communication requests with inconsistent content can cause the CmpFiletransfer component to read internally from an invalid address, potentially leading to a denial-of-service condition. After successful authentication, specifically crafted communication requests c...
[]
null
6.5
null
null
ICSA-22-356-03
Mitsubishi Electric MELSEC iQ-R, iQ-L Series and MELIPC Series (Update B)
A denial-of-service vulnerability due to improper resource shutdown or release exists in Mitsubishi Electric MELSEC iQ-R, iQ-L series CPU module, and MELIPC series. This vulnerability could allow a remote attacker to cause a denial-of-service condition in the module's ethernet communication by sending specially crafted...
[]
null
null
7.5
null
ICSMA-18-058-01
Medtronic 2090 Carelink Programmer Vulnerabilities (Update C)
The affected product uses a per-product username and password that is stored in a recoverable format.CVE-2018-5446 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been calculated; the CVSS vector string is (AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N). The affected product 's software deployment networ...
[]
null
null
7.1
null
ICSA-20-051-01
ICSA-20-051-01_B&R Automation Studio and Automation Runtime
The affected products are vulnerable to a weakness in SNMP service, which allows unauthenticated users to modify the configuration via the service.CVE-2019-19108 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H).
[]
null
null
9.4
null
ICSA-18-163-01
Schneider Electric U.motion Builder
An input string may be evaluated as a command by the application. An attacker could exploit this to execute code, read the stack, or cause a segmentation fault in the running application.CVE-2018-7784 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (A...
[]
null
null
5.3
null
ICSA-19-183-02
Quest KACE Systems Management Appliance
The vulnerability allows unintentional access to the appliance leveraging functions of the troubleshooting tools located in the administrator user interface. CVE-2019-10973 has been assigned to this vulnerability. A CVSS v3 base score of 2.7 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:...
[]
null
null
2.7
null
ICSA-18-044-01
WAGO PFC200 Series
An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during ...
[]
null
null
9.8
null
ICSA-20-112-01
Inductive Automation Ignition
An unprotected logging route may allow an attacker to write endless log statements into the database without space limits or authentication. This results in consuming the entire available hard-disk space, causing a denial-of-service condition.CVE-2020-10641 has been assigned to this vulnerability. A CVSS v3 base score ...
[]
null
null
9.1
null
ICSA-21-257-09
Siemens NX
The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process. The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user s...
[]
null
7.1
null
null
ICSMA-17-215-02
ICSMA-17-215-02_Siemens Molecular Imaging Vulnerabilities
An unauthenticated remote attacker could execute arbitrary code by sending specially crafted HTTP requests to the Microsoft web server (Port 80/TCP and Port 443/TCP) of affected devices. An unauthenticated remote attacker could execute arbitrary code by sending a specially crafted request to the HP Client automation se...
[]
null
null
9.8
null
ICSA-21-315-02
Multiple Data Distribution Service (DDS) Implementations (Update A)
Eclipse CycloneDDS versions prior to 0.8.0 are vulnerable to a write-what-where condition, which may allow an attacker to write arbitrary values in the XML parser.CVE-2021-38441 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C...
[]
null
null
7.5
null
ICSMA-20-170-05
BIOTRONIK CardioMessenger II
The affected products do not properly enforce mutual authentication with the BIOTRONIK Remote Communication infrastructure. CVE-2019-18246 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). The affected products tran...
[]
null
null
4.6
null
ICSA-23-103-11
Siemens Teamcenter Visualization and JT2Go
The APDFL.dll contains a memory corruption vulnerability while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
[]
null
7.8
null
null
ICSA-23-341-02
Schweitzer Engineering Laboratories SEL-411L
An Improper Restriction of Rendered UI Layers or Frames in the Schweitzer Engineering Laboratories SEL-411L could allow an unauthenticated attacker to perform clickjacking based attacks against an authenticated and authorized user.
[]
null
4.3
null
null
ICSA-20-177-02
Rockwell Automation FactoryTalk Services Platform XXE
A local, authenticated attacker could use an XML External Entity (XXE) attack to exploit weakly configured XML files to access local or remote content. A successful exploit could potentially cause a denial-of-service condition and allow the attacker to arbitrarily read any local file via system-level services.CVE-2020-...
[]
null
null
8.4
null
ICSA-18-044-01
WAGO PFC200 Series
An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during ...
[]
null
null
9.8
null
ICSA-20-112-01
Inductive Automation Ignition
An unprotected logging route may allow an attacker to write endless log statements into the database without space limits or authentication. This results in consuming the entire available hard-disk space, causing a denial-of-service condition.CVE-2020-10641 has been assigned to this vulnerability. A CVSS v3 base score ...
[]
null
null
9.1
null
ICSA-21-005-06
Delta Electronics CNCSoft ScreenEditor
A stack-based buffer overflow may exist when processing specially crafted project files, which may allow an attacker to execute arbitrary code.CVE-2020-27281 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-19-281-02
GE Mark VIe Controller
The affected product has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials.CVE-2019-13554 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L). The a...
[]
null
null
6.8
null
ICSA-20-105-04
Siemens Climatix (Update A)
A persistent cross-site scripting (XSS) vulnerability exists in the "Server Config" web interface of the affected devices that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user. The security vulnerability could be exploited by...
[]
null
6.1
null
null
ICSA-23-348-13
Siemens SICAM Q100 Devices
The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user. Affected devices are missing cookie protection flags when using the ...
[]
null
5.5
null
null
ICSA-23-040-01
Control By Web X-400, X-600M
Control By Web X-400 devices are vulnerable to a cross-site scripting attack, which could result in private and session information being transferred to the attacker.-CVE-2023-23553 has been assigned to this vulnerability. A CVSS v3 base score of 4.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S...
[]
null
null
9.1
null
ICSMA-19-241-02
Philips HDI 4000 Ultrasound
The HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product.CVE-2019-10988 has been assigned to this vulnerability. A CVSS v3 base score of 3.0 has been calculated; the CVSS vect...
[]
null
null
3
null
ICSA-22-242-11
Sensormatic Electronics iSTAR
The affected product is vulnerable to a command injection that could allow an unauthenticated user root access to the system.CVE-2022-21941 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).
[]
null
null
10
null
ICSA-19-162-04
Siemens SCALANCE X (Update B)
The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.
[]
null
7.1
null
null
ICSA-18-018-01A
Siemens SIMATIC WinCC Add-On (Update A)
Malformed ASN1 streams in V2C and similar input files can be used to generate stack-based buffer overflows. The vulnerability could allow arbitrary code execution. CVE-2017-11496 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:...
[]
null
null
5.3
null
ICSA-22-137-01
Circutor COMPACT DC-S BASIC
A buffer overflow vulnerability has been detected in the firewall function of the device management web portal. The device runs a CGI binary (index.cgi) to offer a management web application. Once authenticated with valid credentials in this web portal, a potential attacker could submit any "Address" value and it would...
[]
null
null
6.8
null
ICSA-19-339-02
Weidmueller Industrial Ethernet Switches
The authentication mechanism has no brute-force prevention.CVE-2019-16670 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Remote authenticated users can crash a device by using a special packet.CVE-2019-16671 has ...
[]
null
null
9.8
null
ICSA-23-278-02
Qognify NiceVision
Qognify NiceVision versions 3.1 and prior are vulnerable to exposing sensitive information using hard-coded credentials. With these credentials an attacker can retrieve information about the cameras, user information, and modify database records.
[]
null
null
10
null
ICSA-23-257-07
Rockwell Automation Pavilion8
The JMX Console within the Pavilion is exposed to application users and does not require authentication. If exploited, a malicious user could retrieve other application users' session data and or log users out of their sessions.
[]
null
null
8.8
null
ICSMA-21-084-01
Philips Gemini PET/CT Family
The software stores sensitive information in a removable media device that does not have built-in access control.CVE-2021-27456 has been assigned to this vulnerability. A CVSS v3 base score of 2.4 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
2.4
null
ICSA-23-201-01
Schneider Electric EcoStruxure Products, Modicon PLCs, and Programmable Automation Controllers
The affected components contain a vulnerability that could cause arbitrary code execution, a denial-of-service condition, and loss of confidentiality & integrity when a malicious project file is loaded onto the controller.
[]
null
null
7.5
null
ICSA-21-131-01
Omron CX-One
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.CVE-2021-27413 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-22-349-19
Siemens SICAM PAS
Affected software does not properly secure a folder containing library files. This could allow an attacker to place a custom malicious DLL in this folder which is then run with SYSTEM rights when a service is started that requires this DLL. At the time of assigning the CVE, the affected firmware version of the compone...
[]
null
8.3
null
null
ICSMA-18-107-01
Abbott Laboratories Defibrillator
The device 's authentication algorithm, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the ICD or CRT-D via RF communications.CVE-2017-12712 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has ...
[]
null
null
5.3
null
ICSA-23-012-06
Johnson Controls Metasys
Under certain circumstances, the affected versions of Johnson Controls Metasys ADS/ADX/OAS Servers could expose plaintext credentials through application programmable interface (API) calls.-CVE-2021-36204 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (...
[]
null
null
7.8
null
ICSA-23-103-13
Siemens SCALANCE Switch Families
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption. An issue was discovered in Wind River VxWorks. The memory...
[]
null
9.8
null
null
ICSA-21-229-01
ThroughTek Kalay P2P SDK
The affected ThroughTek P2P products may be vulnerable to improper access controls. This vulnerability can allow an attacker to access sensitive information (such as camera feeds) or perform remote code execution.CVE-2021-28372 has been assigned to this vulnerability. A CVSS v3 base score 9.8 has been calculated; the C...
[]
null
null
9.6
null
ICSA-23-017-02
Mitsubishi Electric MELSEC iQ-F, iQ-R Series
Mitsubishi Electric MELSEC iQ-F and iQ-R Series products both contain an authentication bypass vulnerability in the WEB server function due to predictable seed in the pseudo-random number generator. CVE-2022-40267 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been assigned; the CVSS vector st...
[]
null
null
5.9
null
ICSA-21-012-04
Siemens Solid Edge
Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supp...
[]
null
7.8
null
null
ICSA-22-333-05
Mitsubishi Electric FA Engineering Software
If this vulnerability is exploited, sensitive information could be disclosed. As a result, unauthorized users can gain access to the CPU module and the OPC UA server module. If this vulnerability is exploited, sensitive information could be disclosed. As a result, unauthorized users could view programs and project file...
[]
null
null
3.7
null
ICSA-22-144-01
Rockwell Automation Logix Controllers
A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.CVE-2022...
[]
null
null
6.8