0 to 70% (vs. fixed speed) while reducing installation time.
<|ref|>image<|/ref|><|det|>[[54, 241, 405, 518]]<|/det|>
<|ref|>title<|/ref|><|det|>[[55, 531, 197, 542]]<|/det|>
SPECIFICATIONS
<|ref|>table<|/ref|><|det|>[[55, 548, 488, 953]]<|/det|>
| Indoor enclosures | IP20 Open, TYPE 1, TYPE 12 |
| Outdoor enclosures | TYPE 3R, TYPE 4X |
| Input supply | 1.5-600 hp (frame A-D) wall or base mounted |
| Ambient temperature | \(14^{\circ }F-113^{\circ }F(-10^{\circ }C-45^{\circ }C)\) Higher temperatures can be achieved by derating the output amperage of the drive 10% for up to 122掳F(50掳C) |
| Communication | Modbus庐 RTU, Metasys N2, FLN, and BACnet standard Others available with option cards |
| Altitudes | At altitudes from 0 to 1,000 meters (0 to 3,300 ft) Nameplate rated current is available Derate for altitudes above 1,000 (3,300 ft) with a maximum operating altitude of 3,000 m(9,900 ft) Consult factory for applications above 3,000 m(9,900 ft) |
| Relative humidity | Lower than 95% without condensation |
| Electrical - input power | 3 phase 380 V to 480 V卤10% 1 phase 200 V to 240 V卤10% 3 phase 200 V to 240 V卤10% 3 phase 525 V to 600 V卤10% Frequency 50 or 60 Hz,卤2 Hz |
| Electrical - output power | 3 phase from 0 to V supply |
<|ref|>title<|/ref|><|det|>[[510, 310, 752, 384]]<|/det|>
AQUAVAR庐 IPC VARIABLE SPEED CONTROLLER
<|ref|>title<|/ref|><|det|>[[510, 433, 598, 444]]<|/det|>
FEATURES
<|ref|>text<|/ref|><|det|>[[512, 456, 925, 486]]<|/det|> 路Easier start-up and programming with Start-Up Genie
<|ref|>text<|/ref|><|det|>[[512, 475, 888, 504]]<|/det|> 路Wide range of standard and permanent magnet motors with power up to 600 hp
<|ref|>text<|/ref|><|det|>[[512, 512, 935, 541]]<|/det|> 路Multi-pump configuration for up to four (4) pumps - no need for programmable logic controller (PLC)
<|ref|>text<|/ref|><|det|>[[512, 549, 890, 576]]<|/det|> 路Remote commissioning and monitoring with USB connectivity and software
<|ref|>text<|/ref|><|det|>[[512, 584, 928, 595]]<|/det|> 路Two wire multi-pump connection for faster installation
<|ref|>text<|/ref|><|det|>[[512, 605, 917, 649]]<|/det|> 路Hand on, off, and auto-on buttons available for easy pump operation at the keypad. No toggling between local and remote operation
<|ref|>text<|/ref|><|det|>[[512, 658, 939, 684]]<|/det|> 路System redundancy with multi-master control in case of drive failure
<|ref|>text<|/ref|><|det|>[[512, 693, 922, 721]]<|/det|> 路BACnet and Modbus as a standard for seamless BMS integration
<|ref|>text<|/ref|><|det|>[[512, 730, 859, 743]]<|/det|> 路Submersible and above ground applications
<|ref|>text<|/ref|><|det|>[[512, 751, 864, 764]]<|/det|> 路Wide range of voltage and enclosure options
<|ref|>text<|/ref|><|det|>[[512, 773, 680, 784]]<|/det|> 路True 208 V coverage
<|ref|>text<|/ref|><|det|>[[512, 794, 747, 806]]<|/det|> 路Dedicated single phase input
<|ref|>text<|/ref|><|det|>[[512, 815, 891, 842]]<|/det|> 路Remote commissioning and monitoring with USB connectivity and software
<|ref|>text<|/ref|><|det|>[[512, 850, 891, 863]]<|/det|> 路In-panel or handheld keypad with backlit display
<|ref|>text<|/ref|><|det|>[[512, 872, 910, 884]]<|/det|> 路Alarm Log for last 5 alarms and maintenance events
<|ref|>text<|/ref|><|det|>[[512, 892, 905, 920]]<|/det|> 路EMC/RFI filters and dual DC-link reactors to reduce drive noise emissions and interference
<|ref|>text<|/ref|><|det|>[[512, 929, 858, 957]]<|/det|> 路I/O expansion cards, factory installed or field configured