0 to 70% (vs. fixed speed) while reducing installation time.
<|ref|>image<|/ref|><|det|>[[54, 241, 405, 518]]<|/det|>
<|ref|>title<|/ref|><|det|>[[55, 531, 197, 542]]<|/det|>
# SPECIFICATIONS
<|ref|>table<|/ref|><|det|>[[55, 548, 488, 953]]<|/det|>
<table><tr><td>Indoor enclosures</td><td>IP20 Open, TYPE 1, TYPE 12</td></tr><tr><td>Outdoor enclosures</td><td>TYPE 3R, TYPE 4X</td></tr><tr><td>Input supply</td><td>1.5-600 hp (frame A-D) wall or base mounted</td></tr><tr><td>Ambient<br>temperature</td><td>\(14^{\circ }F-113^{\circ }F(-10^{\circ }C-45^{\circ }C)\) Higher temperatures can be achieved<br>by derating the output amperage of<br>the drive 10% for up to 122掳F(50掳C)</td></tr><tr><td>Communication</td><td>Modbus庐 RTU, Metasys N2, FLN, and BACnet standard<br>Others available with option cards</td></tr><tr><td>Altitudes</td><td>At altitudes from 0 to 1,000 meters<br>(0 to 3,300 ft)<br>Nameplate rated current is available<br>Derate for altitudes above 1,000<br>(3,300 ft) with a maximum operating<br>altitude of 3,000 m(9,900 ft)<br>Consult factory for applications above<br>3,000 m(9,900 ft)</td></tr><tr><td>Relative humidity</td><td>Lower than 95% without condensation</td></tr><tr><td>Electrical -<br>input power</td><td>3 phase 380 V to 480 V卤10%<br>1 phase 200 V to 240 V卤10%<br>3 phase 200 V to 240 V卤10%<br>3 phase 525 V to 600 V卤10%<br>Frequency 50 or 60 Hz,卤2 Hz</td></tr><tr><td>Electrical -<br>output power</td><td>3 phase from 0 to V supply</td></tr></table>
<|ref|>title<|/ref|><|det|>[[510, 310, 752, 384]]<|/det|>
# AQUAVAR庐 IPC VARIABLE SPEED CONTROLLER
<|ref|>title<|/ref|><|det|>[[510, 433, 598, 444]]<|/det|>
# FEATURES
<|ref|>text<|/ref|><|det|>[[512, 456, 925, 486]]<|/det|>
路Easier start-up and programming with Start-Up Genie
<|ref|>text<|/ref|><|det|>[[512, 475, 888, 504]]<|/det|>
路Wide range of standard and permanent magnet motors with power up to 600 hp
<|ref|>text<|/ref|><|det|>[[512, 512, 935, 541]]<|/det|>
路Multi-pump configuration for up to four (4) pumps - no need for programmable logic controller (PLC)
<|ref|>text<|/ref|><|det|>[[512, 549, 890, 576]]<|/det|>
路Remote commissioning and monitoring with USB connectivity and software
<|ref|>text<|/ref|><|det|>[[512, 584, 928, 595]]<|/det|>
路Two wire multi-pump connection for faster installation
<|ref|>text<|/ref|><|det|>[[512, 605, 917, 649]]<|/det|>
路Hand on, off, and auto-on buttons available for easy pump operation at the keypad. No toggling between local and remote operation
<|ref|>text<|/ref|><|det|>[[512, 658, 939, 684]]<|/det|>
路System redundancy with multi-master control in case of drive failure
<|ref|>text<|/ref|><|det|>[[512, 693, 922, 721]]<|/det|>
路BACnet and Modbus as a standard for seamless BMS integration
<|ref|>text<|/ref|><|det|>[[512, 730, 859, 743]]<|/det|>
路Submersible and above ground applications
<|ref|>text<|/ref|><|det|>[[512, 751, 864, 764]]<|/det|>
路Wide range of voltage and enclosure options
<|ref|>text<|/ref|><|det|>[[512, 773, 680, 784]]<|/det|>
路True 208 V coverage
<|ref|>text<|/ref|><|det|>[[512, 794, 747, 806]]<|/det|>
路Dedicated single phase input
<|ref|>text<|/ref|><|det|>[[512, 815, 891, 842]]<|/det|>
路Remote commissioning and monitoring with USB connectivity and software
<|ref|>text<|/ref|><|det|>[[512, 850, 891, 863]]<|/det|>
路In-panel or handheld keypad with backlit display
<|ref|>text<|/ref|><|det|>[[512, 872, 910, 884]]<|/det|>
路Alarm Log for last 5 alarms and maintenance events
<|ref|>text<|/ref|><|det|>[[512, 892, 905, 920]]<|/det|>
路EMC/RFI filters and dual DC-link reactors to reduce drive noise emissions and interference
<|ref|>text<|/ref|><|det|>[[512, 929, 858, 957]]<|/det|>
路I/O expansion cards, factory installed or field configured