38.533
16.6.4.1 NR SA FR1 SSB based L1-RSRP measurement when DRX is not used for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.1.1 Test purpose
To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in 38.133 [6] clause 9.5B.4.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.1.2 Test applicability
This test applies to all types of NR RedCap UE with 1Rx from release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.1.4.1 Initial conditions
Same as the initial conditions given in clause 6.6.4.1.4.1 with following exceptions: - Table 6.6.4.1.4.1-1 is replaced by Table 16.6.4.1.4.1-1. - Table 6.6.4.1.4.1-2 is replaced by Table 16.6.4.1.4.1-3. - Table 6.6.4.1.4.1-3 is replaced by Table 16.6.4.1.4.1-2. Table 16.6.4.1.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.1.4.2 Test procedure
Same as the test procedure given in clause 6.6.4.1.4.2 with following exceptions: - Step 5 in test procedure given in clause 6.6.4.1.4.2 is replaced by following step. 5. The UE shall start sending valid L1-RSRP reports. The SS shall check following requirements: - R1: the UE shall start to transmit valid reports no la...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.1.4.3 Message contents
Same as the message contents given in clause 6.6.4.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.1.5 Test requirement
Same as the test requirements given in clause 6.6.4.1.5 with following exceptions: - Table 6.6.4.1.5-1 is replaced by Table 16.6.4.1.5-1. - Table 6.6.4.1.5-2 is replaced by Table 16.6.4.1.5-2. - Table 6.6.4.1.5-3 is replaced by Table 16.6.4.1.5-3. - Table 6.6.4.1.5-4 is replaced by Table 16.6.4.1.5-4. Table 16.6.4.1.5-...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2 NR SA FR1 SSB based L1-RSRP measurement when DRX is not used for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2.1 Test purpose
To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in 38.133 [6] clause 9.5B.4.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2.2 Test applicability
This test applies to all types of NR RedCap UE with 2Rx from release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2.4.1 Initial conditions
Same as the initial conditions given in clause 6.6.4.1.4.1 with following exceptions: - Table 6.6.4.1.4.1-1 is replaced by Table 16.6.4.2.4.1-1. - Table 6.6.4.1.4.1-2 is replaced by Table 16.6.4.2.4.1-3. - Table 6.6.4.1.4.1-3 is replaced by Table 16.6.4.2.4.1-2. Table 16.6.4.2.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2.4.2 Test procedure
Same as the test procedure given in clause 6.6.4.1.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2.4.3 Message contents
Same as the message contents given in clause 6.6.4.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.2.5 Test requirement
Same as the test requirements given in clause 6.6.4.1.5 with following exceptions: - Table 6.6.4.1.5-1 is replaced by Table 16.6.4.2.5-1. Table 16.6.4.2.5-1: SSB specific test parameters Parameter Config Unit SSB#0 SSB#1 T1 T2 T1 T2 Note2 1~4 dBm/15kHz -94.65 Note2 1,2,4 dBm/SSB SCS -94.65 3 -91.65 1~4 dB 0 0 -Infinity...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3 NR SA FR1 SSB based L1-RSRP measurement when DRX is used for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3.1 Test purpose
To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in 38.133 [6] clause 9.5B.4.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3.2 Test applicability
This test applies to all types of NR RedCap UE with 1Rx from release 17 onwards and supporting long DRX cycle.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3.4.1 Initial conditions
Same as the initial conditions given in clause 6.6.4.2.4.1 with following exceptions: - Table 6.6.4.2.4.1-1 is replaced by Table 16.6.4.3.4.1-1. - Table 6.6.4.2.4.1-2 is replaced by Table 16.6.4.3.4.1-3. - Table 6.6.4.2.4.1-3 is replaced by Table 16.6.4.3.4.1-2. Table 16.6.4.3.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3.4.2 Test procedure
Same as the test procedure given in clause 6.6.4.2.4.2 with following exceptions: - Step 5 in test procedure given in clause 6.6.4.2.4.2 is replaced by following step. 5. The UE shall start sending valid L1-RSRP reports. The SS shall check following requirements: - R1: the UE shall start to transmit valid reports no la...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3.4.3 Message contents
Same as the message contents given in clause 6.6.4.2.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.3.5 Test requirement
Same as the test requirements given in clause 6.6.4.2.5 with following exceptions: - Table 6.6.4.2.5-1 is replaced by Table 16.6.4.3.5-1. - Table 6.6.4.2.5-2 is replaced by Table 16.6.4.3.5-2. - Table 6.6.4.2.5-3 is replaced by Table 16.6.4.3.5-3. - Table 6.6.4.2.5-4 is replaced by Table 16.6.4.3.5-4. Table 16.6.4.3.5-...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4 NR SA FR1 SSB based L1-RSRP measurement when DRX is used for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4.1 Test purpose
To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in 38.133 [6] clause 9.5B.4.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4.2 Test applicability
This test applies to all types of NR RedCap UE with 2Rx from release 17 onwards and supporting long DRX cycle.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4.4.1 Initial conditions
Same as the initial conditions given in clause 6.6.4.2.4.1 with following exceptions: - Table 6.6.4.2.4.1-1 is replaced by Table 16.6.4.4.4.1-1. - Table 6.6.4.2.4.1-2 is replaced by Table 16.6.4.4.4.1-3. - Table 6.6.4.2.4.1-3 is replaced by Table 16.6.4.4.4.1-2. Table 16.6.4.4.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4.4.2 Test procedure
Same as the test procedure given in clause 6.6.4.2.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4.4.3 Message contents
Same as the message contents given in clause 6.6.4.2.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.4.5 Test requirement
Same as the test requirements given in clause 6.6.4.2.5 with following exceptions: - Table 6.6.4.2.5-1 is replaced by Table 16.6.4.4.5-1. Table 16.6.4.4.5-1: SSB specific test parameters Parameter Config Unit SSB#0 SSB#1 T1 T2 T1 T2 Note2 1~4 dBm/15kHz -94.65 Note2 1,2,4 dBm/SSB SCS -94.65 3 -91.65 1~4 dB 0 0 -Infinity...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5 NR SA FR1 CSI-RS based L1-RSRP measurement when DRX is not used for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5.1 Test purpose
To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in TS 38.133 [6] clause 9.5B.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5.2 Test applicability
This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.5.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5.4.1 Initial conditions
Same as the initial conditions given in clause 6.6.4.3.4.1 with following exceptions: - Table 6.6.4.3.4.1-1 is replaced by Table 16.6.4.5.4.1-1. - Table 6.6.4.3.4.1-2 is replaced by Table 16.6.4.5.4.1-2. - Table 6.6.4.3.4.1-3 is replaced by Table 16.6.4.5.4.1-3. Table 16.6.4.5.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5.4.2 Test procedure
Same as the test procedure given in clause 6.6.4.3.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5.4.3 Message contents
Same as the message contents given in clause 6.6.4.3.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.5.5 Test requirement
Same as the test requirements given in clause 6.6.4.3.5 with following exceptions: - Table 6.6.4.3.5-1 is replaced by Table 16.6.4.5.5-1. - Table 6.6.4.3.5-2 is replaced by Table 16.6.4.5.5-2. - Table 6.6.4.3.5-3 is replaced by Table 16.6.4.5.5-3. - Table 6.6.4.3.5-4 is replaced by Table 16.6.4.5.5-4. Table 16.6.4.5.5-...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6 NR SA FR1 CSI-RS based L1-RSRP measurement when DRX is not used for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6.1 Test purpose
To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in TS 38.133 [6] clause 9.5B.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6.2 Test applicability
This test applies to all types of NR RedCap UE with 2 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.6.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6.4.1 Initial conditions
Same as the initial conditions given in clause 6.6.4.3.4.1 with following exceptions: - Table 6.6.4.3.4.1-1 is replaced by Table 16.6.4.6.4.1-1. - Table 6.6.4.3.4.1-2 is replaced by Table 16.6.4.6.4.1-2. - Table 6.6.4.3.4.1-3 is replaced by Table 16.6.4.6.4.1-3. Table 16.6.4.6.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6.4.2 Test procedure
Same as the test procedure given in clause 6.6.4.3.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6.4.3 Message contents
Same as the message contents given in clause 6.6.4.3.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.6.5 Test requirement
Same as the test requirements given in clause 6.6.4.3.5 with following exceptions: - Table 6.6.4.3.5-1 is replaced by Table 16.6.4.6.5-1. Table 16.6.4.6.5-1: Cell specific test parameters Parameter Unit CSI-RS#0 CSI-RS#1 Note1 dBm/15kHz -94.65 Note1 Config 1,2,4 dBm/SCS -94.65 Config 3 -91.65 dB 0 3.5 CSI-RS RSRP Note2...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7 NR SA FR1 CSI-RS based L1-RSRP measurement when DRX is used for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7.1 Test purpose
To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in TS 38.133 [6] clause 9.5B.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7.2 Test applicability
This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards supporting long DRX cycle.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.7.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7.4.1 Initial conditions
Same as the initial conditions given in clause 6.6.4.4.4.1 with following exceptions: - Table 6.6.4.4.4.1-1 is replaced by Table 16.6.4.7.4.1-1. - Table 6.6.4.4.4.1-2 is replaced by Table 16.6.4.7.4.1-2. - Table 6.6.4.4.4.1-3 is replaced by Table 16.6.4.7.4.1-3. Table 16.6.4.7.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7.4.2 Test procedure
Same as the test procedure given in clause 6.6.4.4.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7.4.3 Message contents
Same as the message contents given in clause 6.6.4.4.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.7.5 Test requirement
Same as the test requirements given in clause 6.6.4.4.5 with following exceptions: - Table 6.6.4.4.5-1 is replaced by Table 16.6.4.7.5-1. - Table 6.6.4.4.5-2 is replaced by Table 16.6.4.7.5-2. - Table 6.6.4.4.5-3 is replaced by Table 16.6.4.7.5-3. - Table 6.6.4.4.5-4 is replaced by Table 16.6.4.7.5-4. Table 16.6.4.7.5-...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8 NR SA FR1 CSI-RS based L1-RSRP measurement when DRX is used for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8.1 Test purpose
To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in TS 38.133 [6] clause 9.5B.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8.2 Test applicability
This test applies to all types of NR RedCap UE with 2 Rx from Release 17 onwards supporting long DRX cycle.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.8.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8.4.1 Initial conditions
Same as the initial conditions given in clause 6.6.4.4.4.1 with following exceptions: - Table 6.6.4.4.4.1-1 is replaced by Table 16.6.4.8.4.1-1. - Table 6.6.4.4.4.1-2 is replaced by Table 16.6.4.8.4.1-2. - Table 6.6.4.4.4.1-3 is replaced by Table 16.6.4.8.4.1-3. Table 16.6.4.8.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8.4.2 Test procedure
Same as the test procedure given in clause 6.6.4.4.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8.4.3 Message contents
Same as the message contents given in clause 6.6.4.4.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.4.8.5 Test requirement
Same as the test requirements given in clause 6.6.4.4.5 with following exceptions: - Table 6.6.4.4.5-1 is replaced by Table 16.6.4.8.5-1. Table 16.6.4.8.5-1: Cell specific test parameters Parameter Unit CSI-RS#0 CSI-RS#1 Note1 dBm/15kHz -94.65 Note1 Config 1,2,4 dBm/SCS -94.65 Config 3 -91.65 dB 0 3.5 CSI-RS RSRP Note2...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5 NR measurements with autonomous gaps for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.0.1 Minimum conformance requirements for NR SA FR1 intra-frequency CGI identification of NR neighbour cell in FR1 for 1 Rx UE
The requirements in this clause are specified for CGI identification of an NR target cell and are applicable for a UE in RRC_CONNECTED state and configured with SA operation mode. The UE shall identify and report the CGI of a known NR target cell when requested by the network for the purpose of reportCGI. Only one cell...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.0.2 Minimum conformance requirements for NR SA FR1 intra-frequency CGI identification of NR neighbour cell in FR1 for 2 Rx UE
Same as clause 16.6.5.0.1 with the following exception: TSIB1_redcap = 6 * TRMSI-scheduling ms The normative reference for this requirement is TS 38.133 [6] clause 9.11A.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.0.3 Minimum conformance requirements for CGI identification of an E-UTRA cell with autonomous gaps
The requirements in this clause apply when the 1Rx RedCap UE or 2Rx RedCap UE is configured with standalone NR. The UE shall identify and report the CGI when requested by an NR PCell for the purpose ‘reportCGI’. The UE may make autonomous gaps in downlink reception and uplink transmission for receiving MIB and SIB1 mes...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1 NR SA FR1 CGI identification of NR neighbour cell for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1.1 Test Purpose
The purpose of this test is to verify that the UE makes correct reporting of intra-frequency CGI identification of an NR neighbour cell in FR1 with autonomous gaps. This test shall partly verify the measurement requirements in clause 9.11A of TS 38.133 [6].
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1.2 Test Applicability
This test applies to all types of NR RedCap UE with 1Rx from release 17 onwards and supporting acquisition of CGI from neighbour NR cell using autonomous gap.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1.3 Minimum Conformance Requirements
The minimum conformance requirements are specified in clause 16.6.5.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.5.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1.4 Test Description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1.4.1 Initial conditions
This test can be run in the configuration defined in Table 16.6.5.1.4.1-1. Table 16.6.5.1.4.1-1: Supported test configurations Test Case ID Test Config Index Description 16.6.5.1-1 1 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.6.5.1-2 2 15 kHz SSB SCS, 10 MHz bandwidth, TDD duplex mode 16.6.5.1-3 3 30 kHz SSB ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1.4.2 Test procedure
The test consists of two cells: Cell 1 and Cell 2. Cell 1 is the FR1 PCell and Cell 2 is an FR1 neighbour cell on the same frequency as the PCell. The general and cell specific test parameters for PCell and neighbour cell are given in Table 16.6.5.1.4.1-3 and Table 16.6.5.1.5-1, respectively. The test consists of three...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1.4.3 Message contents
Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions: Table 16.6.5.1.4.3-1: Common Exception messages for NR SA FR1 intra-frequency CGI identification of NR neighbour cell in FR1 for 1 Rx UE Default Message Contents Common contents of system information blocks exceptions Default R...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.1.5 Test Requirements
Tables 16.6.5.1.4.1-3 and 16.6.5.1.5-1 define the general parameters and cell specific parameters for this test. Table 16.6.5.1.5-1: NR Cell specific test parameters for SA intra-frequency CGI identification of NR neighbour cell in FR1 Parameter Unit Test configuration Cell 1 Cell 2 T1 T2 T1 T2 TDD configuration 1, 4 N...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2 NR SA FR1 CGI identification of NR neighbour cell for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2.1 Test Purpose
The purpose of this test is to verify that the UE makes correct reporting of intra-frequency CGI identification of an NR neighbour cell in FR1 with autonomous gaps. This test shall partly verify the measurement requirements in clause 9.11A of TS 38.133 [6].
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2.2 Test Applicability
This test applies to all types of NR RedCap UE with 2 Rx from release 17 onwards and supporting acquisition of CGI from neighbour NR cell using autonomous gap.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2.3 Minimum Conformance Requirements
The minimum conformance requirements are specified in clause 16.6.5.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.5.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2.4 Test Description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2.4.1 Initial conditions
This test can be run in the configuration defined in Table 16.6.5.2.4.1-1. Table 16.6.5.2.4.1-1: Supported test configurations Test Case ID Test Config Index Description 16.6.5.2-1 1 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.6.5.2-2 2 15 kHz SSB SCS, 10 MHz bandwidth, TDD duplex mode 16.6.5.2-3 3 30 kHz SSB ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2.4.2 Test procedure
Same as in clause 16.6.5.1.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2.4.3 Message contents
Same as in clause 16.6.5.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.2.5 Test Requirements
Tables 16.6.5.2.4.1-3 and 16.6.5.2.5-1 define the general parameters and cell specific parameters for this test. Table 16.6.5.2.5-1: NR Cell specific test parameters for SA intra-frequency CGI identification of NR neighbour cell in FR1 Parameter Unit Test configuration Cell 1 Cell 2 T1 T2 T1 T2 TDD configuration 1, 4 N...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3 NR SA FR1 - E-UTRA CGI Identification of E-UTRA cell for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3.1 Test purpose
To verify the requirement for identification of a new CGI of E-UTRA cell with autonomous gaps in NR SA in TS 38.133 clause 9.4A.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3.2 Test applicability
This test applies to all types of NR RedCap UE with 1Rx from Release 17 onwards and supporting acquisition of CGI from neighbour E-UTRA cell using autonomous gap.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.5.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.5.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3.4 Test description
The test scenario comprises of one NR carrier and an E-UTRA carrier and two cells. PDCCHs indicating new transmissions shall be sent continuously to ensure that the UE would have ACK/NACK sending during identifying a new CGI of E-UTRAN cell. The test consists of three successive time periods, with time durations of T1,...