f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1 NR SA FR1 SSB based L1-RSRP measurement when DRX is not used for 1 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1.1 Test purpose | To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in 38.133 [6] clause 9.5B.4.1. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1.2 Test applicability | This test applies to all types of NR RedCap UE with 1Rx from release 17 onwards. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.2.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.1. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1.4 Test description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1.4.1 Initial conditions | Same as the initial conditions given in clause 6.6.4.1.4.1 with following exceptions:
- Table 6.6.4.1.4.1-1 is replaced by Table 16.6.4.1.4.1-1.
- Table 6.6.4.1.4.1-2 is replaced by Table 16.6.4.1.4.1-3.
- Table 6.6.4.1.4.1-3 is replaced by Table 16.6.4.1.4.1-2.
Table 16.6.4.1.4.1-1: Supported test configurations
Confi... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1.4.2 Test procedure | Same as the test procedure given in clause 6.6.4.1.4.2 with following exceptions:
- Step 5 in test procedure given in clause 6.6.4.1.4.2 is replaced by following step.
5. The UE shall start sending valid L1-RSRP reports. The SS shall check following requirements:
- R1: the UE shall start to transmit valid reports no la... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1.4.3 Message contents | Same as the message contents given in clause 6.6.4.1.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.1.5 Test requirement | Same as the test requirements given in clause 6.6.4.1.5 with following exceptions:
- Table 6.6.4.1.5-1 is replaced by Table 16.6.4.1.5-1.
- Table 6.6.4.1.5-2 is replaced by Table 16.6.4.1.5-2.
- Table 6.6.4.1.5-3 is replaced by Table 16.6.4.1.5-3.
- Table 6.6.4.1.5-4 is replaced by Table 16.6.4.1.5-4.
Table 16.6.4.1.5-... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2 NR SA FR1 SSB based L1-RSRP measurement when DRX is not used for 2 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2.1 Test purpose | To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in 38.133 [6] clause 9.5B.4.1. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2.2 Test applicability | This test applies to all types of NR RedCap UE with 2Rx from release 17 onwards. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.2.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2.4 Test description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2.4.1 Initial conditions | Same as the initial conditions given in clause 6.6.4.1.4.1 with following exceptions:
- Table 6.6.4.1.4.1-1 is replaced by Table 16.6.4.2.4.1-1.
- Table 6.6.4.1.4.1-2 is replaced by Table 16.6.4.2.4.1-3.
- Table 6.6.4.1.4.1-3 is replaced by Table 16.6.4.2.4.1-2.
Table 16.6.4.2.4.1-1: Supported test configurations
Confi... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2.4.2 Test procedure | Same as the test procedure given in clause 6.6.4.1.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2.4.3 Message contents | Same as the message contents given in clause 6.6.4.1.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.2.5 Test requirement | Same as the test requirements given in clause 6.6.4.1.5 with following exceptions:
- Table 6.6.4.1.5-1 is replaced by Table 16.6.4.2.5-1.
Table 16.6.4.2.5-1: SSB specific test parameters
Parameter
Config
Unit
SSB#0
SSB#1
T1
T2
T1
T2
Note2
1~4
dBm/15kHz
-94.65
Note2
1,2,4
dBm/SSB SCS
-94.65
3
-91.65
1~4
dB
0
0
-Infinity... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3 NR SA FR1 SSB based L1-RSRP measurement when DRX is used for 1 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3.1 Test purpose | To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in 38.133 [6] clause 9.5B.4.1. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3.2 Test applicability | This test applies to all types of NR RedCap UE with 1Rx from release 17 onwards and supporting long DRX cycle. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.2.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3.4 Test description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3.4.1 Initial conditions | Same as the initial conditions given in clause 6.6.4.2.4.1 with following exceptions:
- Table 6.6.4.2.4.1-1 is replaced by Table 16.6.4.3.4.1-1.
- Table 6.6.4.2.4.1-2 is replaced by Table 16.6.4.3.4.1-3.
- Table 6.6.4.2.4.1-3 is replaced by Table 16.6.4.3.4.1-2.
Table 16.6.4.3.4.1-1: Supported test configurations
Confi... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3.4.2 Test procedure | Same as the test procedure given in clause 6.6.4.2.4.2 with following exceptions:
- Step 5 in test procedure given in clause 6.6.4.2.4.2 is replaced by following step.
5. The UE shall start sending valid L1-RSRP reports. The SS shall check following requirements:
- R1: the UE shall start to transmit valid reports no la... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3.4.3 Message contents | Same as the message contents given in clause 6.6.4.2.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.3.5 Test requirement | Same as the test requirements given in clause 6.6.4.2.5 with following exceptions:
- Table 6.6.4.2.5-1 is replaced by Table 16.6.4.3.5-1.
- Table 6.6.4.2.5-2 is replaced by Table 16.6.4.3.5-2.
- Table 6.6.4.2.5-3 is replaced by Table 16.6.4.3.5-3.
- Table 6.6.4.2.5-4 is replaced by Table 16.6.4.3.5-4.
Table 16.6.4.3.5-... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4 NR SA FR1 SSB based L1-RSRP measurement when DRX is used for 2 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4.1 Test purpose | To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in 38.133 [6] clause 9.5B.4.1. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4.2 Test applicability | This test applies to all types of NR RedCap UE with 2Rx from release 17 onwards and supporting long DRX cycle. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.2.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.4. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4.4 Test description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4.4.1 Initial conditions | Same as the initial conditions given in clause 6.6.4.2.4.1 with following exceptions:
- Table 6.6.4.2.4.1-1 is replaced by Table 16.6.4.4.4.1-1.
- Table 6.6.4.2.4.1-2 is replaced by Table 16.6.4.4.4.1-3.
- Table 6.6.4.2.4.1-3 is replaced by Table 16.6.4.4.4.1-2.
Table 16.6.4.4.4.1-1: Supported test configurations
Confi... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4.4.2 Test procedure | Same as the test procedure given in clause 6.6.4.2.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4.4.3 Message contents | Same as the message contents given in clause 6.6.4.2.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.4.5 Test requirement | Same as the test requirements given in clause 6.6.4.2.5 with following exceptions:
- Table 6.6.4.2.5-1 is replaced by Table 16.6.4.4.5-1.
Table 16.6.4.4.5-1: SSB specific test parameters
Parameter
Config
Unit
SSB#0
SSB#1
T1
T2
T1
T2
Note2
1~4
dBm/15kHz
-94.65
Note2
1,2,4
dBm/SSB SCS
-94.65
3
-91.65
1~4
dB
0
0
-Infinity... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5 NR SA FR1 CSI-RS based L1-RSRP measurement when DRX is not used for 1 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5.1 Test purpose | To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in TS 38.133 [6] clause 9.5B.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5.2 Test applicability | This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.3.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.5. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5.4 Test description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5.4.1 Initial conditions | Same as the initial conditions given in clause 6.6.4.3.4.1 with following exceptions:
- Table 6.6.4.3.4.1-1 is replaced by Table 16.6.4.5.4.1-1.
- Table 6.6.4.3.4.1-2 is replaced by Table 16.6.4.5.4.1-2.
- Table 6.6.4.3.4.1-3 is replaced by Table 16.6.4.5.4.1-3.
Table 16.6.4.5.4.1-1: Supported test configurations
Confi... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5.4.2 Test procedure | Same as the test procedure given in clause 6.6.4.3.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5.4.3 Message contents | Same as the message contents given in clause 6.6.4.3.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.5.5 Test requirement | Same as the test requirements given in clause 6.6.4.3.5 with following exceptions:
- Table 6.6.4.3.5-1 is replaced by Table 16.6.4.5.5-1.
- Table 6.6.4.3.5-2 is replaced by Table 16.6.4.5.5-2.
- Table 6.6.4.3.5-3 is replaced by Table 16.6.4.5.5-3.
- Table 6.6.4.3.5-4 is replaced by Table 16.6.4.5.5-4.
Table 16.6.4.5.5-... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6 NR SA FR1 CSI-RS based L1-RSRP measurement when DRX is not used for 2 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6.1 Test purpose | To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in TS 38.133 [6] clause 9.5B.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6.2 Test applicability | This test applies to all types of NR RedCap UE with 2 Rx from Release 17 onwards. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.3.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.6. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6.4 Test description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6.4.1 Initial conditions | Same as the initial conditions given in clause 6.6.4.3.4.1 with following exceptions:
- Table 6.6.4.3.4.1-1 is replaced by Table 16.6.4.6.4.1-1.
- Table 6.6.4.3.4.1-2 is replaced by Table 16.6.4.6.4.1-2.
- Table 6.6.4.3.4.1-3 is replaced by Table 16.6.4.6.4.1-3.
Table 16.6.4.6.4.1-1: Supported test configurations
Confi... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6.4.2 Test procedure | Same as the test procedure given in clause 6.6.4.3.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6.4.3 Message contents | Same as the message contents given in clause 6.6.4.3.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.6.5 Test requirement | Same as the test requirements given in clause 6.6.4.3.5 with following exceptions:
- Table 6.6.4.3.5-1 is replaced by Table 16.6.4.6.5-1.
Table 16.6.4.6.5-1: Cell specific test parameters
Parameter
Unit
CSI-RS#0
CSI-RS#1
Note1
dBm/15kHz
-94.65
Note1
Config 1,2,4
dBm/SCS
-94.65
Config 3
-91.65
dB
0
3.5
CSI-RS RSRP Note2... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7 NR SA FR1 CSI-RS based L1-RSRP measurement when DRX is used for 1 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7.1 Test purpose | To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in TS 38.133 [6] clause 9.5B.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7.2 Test applicability | This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards supporting long DRX cycle. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.3.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.7. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7.4 Test description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7.4.1 Initial conditions | Same as the initial conditions given in clause 6.6.4.4.4.1 with following exceptions:
- Table 6.6.4.4.4.1-1 is replaced by Table 16.6.4.7.4.1-1.
- Table 6.6.4.4.4.1-2 is replaced by Table 16.6.4.7.4.1-2.
- Table 6.6.4.4.4.1-3 is replaced by Table 16.6.4.7.4.1-3.
Table 16.6.4.7.4.1-1: Supported test configurations
Confi... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7.4.2 Test procedure | Same as the test procedure given in clause 6.6.4.4.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7.4.3 Message contents | Same as the message contents given in clause 6.6.4.4.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.7.5 Test requirement | Same as the test requirements given in clause 6.6.4.4.5 with following exceptions:
- Table 6.6.4.4.5-1 is replaced by Table 16.6.4.7.5-1.
- Table 6.6.4.4.5-2 is replaced by Table 16.6.4.7.5-2.
- Table 6.6.4.4.5-3 is replaced by Table 16.6.4.7.5-3.
- Table 6.6.4.4.5-4 is replaced by Table 16.6.4.7.5-4.
Table 16.6.4.7.5-... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8 NR SA FR1 CSI-RS based L1-RSRP measurement when DRX is used for 2 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8.1 Test purpose | To verify that the UE makes correct reporting of L1-RSRP measurement. This test will partly verify the L1-RSRP measurement requirements in TS 38.133 [6] clause 9.5B.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8.2 Test applicability | This test applies to all types of NR RedCap UE with 2 Rx from Release 17 onwards supporting long DRX cycle. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.4.0.1 and 16.6.4.0.3.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.4.8. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8.4 Test description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8.4.1 Initial conditions | Same as the initial conditions given in clause 6.6.4.4.4.1 with following exceptions:
- Table 6.6.4.4.4.1-1 is replaced by Table 16.6.4.8.4.1-1.
- Table 6.6.4.4.4.1-2 is replaced by Table 16.6.4.8.4.1-2.
- Table 6.6.4.4.4.1-3 is replaced by Table 16.6.4.8.4.1-3.
Table 16.6.4.8.4.1-1: Supported test configurations
Confi... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8.4.2 Test procedure | Same as the test procedure given in clause 6.6.4.4.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8.4.3 Message contents | Same as the message contents given in clause 6.6.4.4.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.4.8.5 Test requirement | Same as the test requirements given in clause 6.6.4.4.5 with following exceptions:
- Table 6.6.4.4.5-1 is replaced by Table 16.6.4.8.5-1.
Table 16.6.4.8.5-1: Cell specific test parameters
Parameter
Unit
CSI-RS#0
CSI-RS#1
Note1
dBm/15kHz
-94.65
Note1
Config 1,2,4
dBm/SCS
-94.65
Config 3
-91.65
dB
0
3.5
CSI-RS RSRP Note2... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5 NR measurements with autonomous gaps for RedCap | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.0 Minimum conformance requirements | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.0.1 Minimum conformance requirements for NR SA FR1 intra-frequency CGI identification of NR neighbour cell in FR1 for 1 Rx UE | The requirements in this clause are specified for CGI identification of an NR target cell and are applicable for a UE in RRC_CONNECTED state and configured with SA operation mode.
The UE shall identify and report the CGI of a known NR target cell when requested by the network for the purpose of reportCGI. Only one cell... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.0.2 Minimum conformance requirements for NR SA FR1 intra-frequency CGI identification of NR neighbour cell in FR1 for 2 Rx UE | Same as clause 16.6.5.0.1 with the following exception:
TSIB1_redcap = 6 * TRMSI-scheduling ms
The normative reference for this requirement is TS 38.133 [6] clause 9.11A. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.0.3 Minimum conformance requirements for CGI identification of an E-UTRA cell with autonomous gaps | The requirements in this clause apply when the 1Rx RedCap UE or 2Rx RedCap UE is configured with standalone NR. The UE shall identify and report the CGI when requested by an NR PCell for the purpose ‘reportCGI’. The UE may make autonomous gaps in downlink reception and uplink transmission for receiving MIB and SIB1 mes... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1 NR SA FR1 CGI identification of NR neighbour cell for 1 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1.1 Test Purpose | The purpose of this test is to verify that the UE makes correct reporting of intra-frequency CGI identification of an NR neighbour cell in FR1 with autonomous gaps. This test shall partly verify the measurement requirements in clause 9.11A of TS 38.133 [6]. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1.2 Test Applicability | This test applies to all types of NR RedCap UE with 1Rx from release 17 onwards and supporting acquisition of CGI from neighbour NR cell using autonomous gap. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1.3 Minimum Conformance Requirements | The minimum conformance requirements are specified in clause 16.6.5.0.1.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.5.1. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1.4 Test Description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1.4.1 Initial conditions | This test can be run in the configuration defined in Table 16.6.5.1.4.1-1.
Table 16.6.5.1.4.1-1: Supported test configurations
Test Case ID
Test Config Index
Description
16.6.5.1-1
1
15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode
16.6.5.1-2
2
15 kHz SSB SCS, 10 MHz bandwidth, TDD duplex mode
16.6.5.1-3
3
30 kHz SSB ... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1.4.2 Test procedure | The test consists of two cells: Cell 1 and Cell 2. Cell 1 is the FR1 PCell and Cell 2 is an FR1 neighbour cell on the same frequency as the PCell. The general and cell specific test parameters for PCell and neighbour cell are given in Table 16.6.5.1.4.1-3 and Table 16.6.5.1.5-1, respectively. The test consists of three... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1.4.3 Message contents | Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions:
Table 16.6.5.1.4.3-1: Common Exception messages for NR SA FR1 intra-frequency CGI identification of NR neighbour cell in FR1 for 1 Rx UE
Default Message Contents
Common contents of system information blocks exceptions
Default R... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.1.5 Test Requirements | Tables 16.6.5.1.4.1-3 and 16.6.5.1.5-1 define the general parameters and cell specific parameters for this test.
Table 16.6.5.1.5-1: NR Cell specific test parameters for SA intra-frequency CGI identification of NR neighbour cell in FR1
Parameter
Unit
Test configuration
Cell 1
Cell 2
T1
T2
T1
T2
TDD configuration
1, 4
N... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2 NR SA FR1 CGI identification of NR neighbour cell for 2 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2.1 Test Purpose | The purpose of this test is to verify that the UE makes correct reporting of intra-frequency CGI identification of an NR neighbour cell in FR1 with autonomous gaps. This test shall partly verify the measurement requirements in clause 9.11A of TS 38.133 [6]. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2.2 Test Applicability | This test applies to all types of NR RedCap UE with 2 Rx from release 17 onwards and supporting acquisition of CGI from neighbour NR cell using autonomous gap. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2.3 Minimum Conformance Requirements | The minimum conformance requirements are specified in clause 16.6.5.0.2.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.5.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2.4 Test Description | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2.4.1 Initial conditions | This test can be run in the configuration defined in Table 16.6.5.2.4.1-1.
Table 16.6.5.2.4.1-1: Supported test configurations
Test Case ID
Test Config Index
Description
16.6.5.2-1
1
15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode
16.6.5.2-2
2
15 kHz SSB SCS, 10 MHz bandwidth, TDD duplex mode
16.6.5.2-3
3
30 kHz SSB ... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2.4.2 Test procedure | Same as in clause 16.6.5.1.4.2. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2.4.3 Message contents | Same as in clause 16.6.5.1.4.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.2.5 Test Requirements | Tables 16.6.5.2.4.1-3 and 16.6.5.2.5-1 define the general parameters and cell specific parameters for this test.
Table 16.6.5.2.5-1: NR Cell specific test parameters for SA intra-frequency CGI identification of NR neighbour cell in FR1
Parameter
Unit
Test configuration
Cell 1
Cell 2
T1
T2
T1
T2
TDD configuration
1, 4
N... |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.3 NR SA FR1 - E-UTRA CGI Identification of E-UTRA cell for 1 Rx UE | |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.3.1 Test purpose | To verify the requirement for identification of a new CGI of E-UTRA cell with autonomous gaps in NR SA in TS 38.133 clause 9.4A.4. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.3.2 Test applicability | This test applies to all types of NR RedCap UE with 1Rx from Release 17 onwards and supporting acquisition of CGI from neighbour E-UTRA cell using autonomous gap. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.3.3 Minimum conformance requirements | The minimum conformance requirements are specified in clause 16.6.5.0.3.
The normative reference for this requirement is TS 38.133 [6] clause A.16.6.5.3. |
f6aa351f9dfcf54f60d7745530e70f1e | 38.533 | 16.6.5.3.4 Test description | The test scenario comprises of one NR carrier and an E-UTRA carrier and two cells. PDCCHs indicating new transmissions shall be sent continuously to ensure that the UE would have ACK/NACK sending during identifying a new CGI of E-UTRAN cell.
The test consists of three successive time periods, with time durations of T1,... |