hash
stringlengths
32
32
doc_id
stringlengths
5
12
section
stringlengths
5
1.47k
content
stringlengths
0
6.67M
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.6.5.3.4.1-1. Table 16.6.5.3.4.1-1: Supported test configurations Configuration Description 16.6.5.3-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode, LTE FDD 16.6.5.3-2 NR 15 kHz SSB SCS, 10 MHz bandwidth, TDD duplex mode, LTE FDD 16.6.5.3...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3.4.2 Test procedure
Throughout the test, the UE shall be scheduled to perform DL reception on every slot suitable for DL. 1. Ensure the UE is in State RRC_CONNECTED with generic procedure parameters Connectivity NR, Connected without release On according to TS 38.508-1 [14] clause 4.5. Establish SRB2 and DRB in the RRC Reconfiguration mes...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3.4.3 Message contents
Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions: Table 16.6.1.1.4.3-1: Common Exception messages Default Message Contents Common contents of system information blocks exceptions Default RRC messages and information elements contents exceptions Table H.3.1-1 Table 16.6.1.1.4.3...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.3.5 Test requirements
Table 16.6.5.3.4.1-3, Table 16.6.5.3.5-1 and Table 16.6.5.3.5-2 define the primary level settings including test tolerances for the test. Table 16.6.5.3.5-3: NR cell specific test parameters (Cell 1) Parameter Unit Configuration Cell 1 T1 T2 T3 RF channel number 1,2,3,4,5,6 1 Duplex mode 1,4 FDD 2,3,5,6 TDD TDD Configu...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4 NR SA FR1 - E-UTRA CGI Identification of E-UTRA cell for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4.1 Test purpose
To verify the requirement for identification of a new CGI of E-UTRA cell with autonomous gaps in NR SA in TS 38.133 clause 9.4A.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4.2 Test applicability
This test applies to all types of NR RedCap UE with 2Rx from Release 17 onwards and supporting acquisition of CGI from neighbour E-UTRA cell using autonomous gap.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.6.5.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.16.6.5.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4.4 Test description
Same as the test description given in clause 16.6.5.3.4
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4.4.1 Initial conditions
Same as the initial conditions given in clause 16.6.5.3.4 with following exceptions: - Table 16.6.5.3.4.1-1 is replaced by Table 16.6.5.4.4.1-1; - Table 16.6.5.3.4.1-2 is replaced by Table 16.6.5.4.4.1-2; - Table 16.6.5.3.4.1-3 is replaced by Table 16.6.5.4.4.1-3. Table 16.6.5.4.4.1-1: Supported test configurations Con...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4.4.2 Test procedure
Same as the test procedure given in clause 16.6.5.3.4.2 with following exceptions: - Step 12 in clause 16.6.5.3.4.2 is replaced by following step: 12. If the UE a) transmits a MeasurementReport message containing CGI of E-UTRA Cell 2 less than 200 ms from the beginning of time period T3, and b) transmits ACK/NACKs no l...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4.4.3 Message contents
Same as the message contents given in clause 16.6.5.3.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.6.5.4.5 Test requirements
Table 16.6.5.4.4.1-3, Table 16.6.5.4.5-1 and Table 16.6.5.4.5-2 define the primary level settings including test tolerances for the test. Table 16.6.5.4.5-3: NR cell specific test parameters (Cell 1) Parameter Unit Configuration Cell 1 T1 T2 T3 RF channel number 1,2,3,4,5,6 1 Duplex mode 1,4 FDD 2,3,5,6 TDD TDD Configu...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7 Measurement performance requirements for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1 SS-RSRP for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.0.1 Intra-frequency absolute SS-RSRP measurement accuracy requirements
The accuracy requirements in clause 6.7.1.0.1 shall apply when RedCap UE is capable of 2Rx. When UE is only required to support 1RX, the absolute accuracy requirements in Table 16.7.1.0.1-1 are valid under the following conditions: - Conditions defined in clause 7.3 of TS 38.101-1 [2] for reference sensitivity are fulf...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.0.2 Intra-frequency relative SS-RSRP measurement accuracy requirements
The accuracy requirements in clause 6.7.1.0.2 shall apply when RedCap UE is capable of 2Rx. When UE is only required to support 1RX, the absolute accuracy requirements in Table 16.7.1.0.2-1 are valid under the following conditions: - Conditions defined in clause 7.3 of TS 38.101-1 [2] for reference sensitivity are fulf...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.0.3 Inter-frequency absolute SS-RSRP measurement accuracy requirements
The accuracy requirements in clause 6.7.1.0.3 shall apply when RedCap UE is capable of 2Rx. When UE is only required to support 1RX, the absolute accuracy requirements in Table 16.7.1.0.3-1 are valid under the following conditions: - Conditions defined in clause 7.3 of TS 38.101-1 [2] for reference sensitivity are fulf...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.0.4 Inter-frequency relative SS-RSRP measurement accuracy requirements
The accuracy requirements in clause 6.7.1.0.4 shall apply when RedCap UE is capable of 2Rx. When UE is only required to support 1RX, the absolute accuracy requirements in Table 16.7.1.0.4-1 are valid under the following conditions: - Conditions defined in clause 7.3 of TS 38.101-1 [2] for reference sensitivity are fulf...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1 Intra-frequency measurements for RedCap for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1 NR SA FR1 SS-RSRP absolute measurement accuracy for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1.1 Test purpose
The purpose of this test is to verify that the intra-frequency SS-RSRP absolute measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1.2 Test applicability
This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.1.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.1.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.7.1.1.1.4.1-1. Table 16.7.1.1.1.4.1-1: NR SA FR1 SS-RSRP measurement accuracy supported test configurations Test Case ID Description 16.7.1.1.1-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.7.1.1.1-2 NR 15 kHz SSB SCS, 10 MHz bandwid...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.1.1.4.2 with following exceptions: - Table 6.7.1.1.1.5-1 is replaced by Table 16.7.1.1.1.5-1. - Table 6.7.1.1.1.5-2 is replaced by Table 16.7.1.1.1.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1.4.3 Message contents
Same as the message contents given in clause 6.7.1.1.4.3 with following exceptions: - Specific message contents exceptions for test configuration 6.7.1.1-1 applies to test configuration 16.7.1.1.1-4. - Table H.3.1-3 is used with associated condition SSB.1 RedCap FR1 for test configuration 16.7.1.1.1-3
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.1.5 Test requirement
Table 16.7.1.1.1.5-1 defines the primary level settings including test tolerances for all tests. Each SS-RSRP measurement report for each of the tests in Table 16.7.1.1.1.5-1 shall meet the corresponding absolute accuracy requirements in Table 16.7.1.1.1.5-2 for test configurations 1, 2 and 4 and the corresponding abso...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2 NR SA FR1 SS-RSRP relative measurement accuracy for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2.1 Test purpose
The purpose of this test is to verify that the intra-frequency SS-RSRP relative measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2.2 Test applicability
This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.1.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.1.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.7.1.1.2.4.1-1. Table 16.7.1.1.2.4.1-1: NR SA FR1 SS-RSRP measurement accuracy supported test configurations Test Case ID Description 16.7.1.1.2-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.7.1.1.2-2 NR 15 kHz SSB SCS, 10 MHz bandwid...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.1.2.4.2 with following exceptions: - Table 6.7.1.1.2.5-1 is replaced by Table 16.7.1.1.2.5-1. - Table 6.7.1.1.2.5-2 is replaced by Table 16.7.1.1.2.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2.4.3 Message contents
Message contents are same as in clause 16.7.1.1.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.1.2.5 Test requirement
Table 16.7.1.1.2.5-1 defines the primary level settings including test tolerances for all tests. Each SS-RSRP measurement report for each of the tests in Table 16.7.1.1.2.5-1 shall meet the corresponding relative accuracy requirements in Table 16.7.1.1.2.5-2. Table 16.7.1.1.2.5-1: Same as Table 16.7.1.1.1.5-1 with the ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2 Intra-frequency measurements for RedCap for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1 NR SA FR1 SS-RSRP absolute measurement accuracy for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1.1 Test purpose
The purpose of this test is to verify that the intra-frequency SS-RSRP absolute measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1.2 Test applicability
This test applies to all types of NR RedCap UE with 2 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.1.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.1.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.7.1.2.1.4.1-1. Table 16.7.1.2.1.4.1-1: NR SA FR1 SS-RSRP measurement accuracy supported test configurations Test Case ID Description 16.7.1.2.1-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.7.1.2.1-2 NR 15 kHz SSB SCS, 10 MHz bandwid...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.1.1.4.2 with following exceptions: - Table 6.7.1.1.1.5-1 is replaced by Table 16.7.1.2.1.5-1. - Table 6.7.1.1.1.5-2 is replaced by Table 16.7.1.2.1.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1.4.3 Message contents
Same as the message contents given in clause 6.7.1.1.4.3 with following exceptions: - Specific message contents exceptions for test configuration 6.7.1.1-1 applies to test configuration 16.7.1.2.1-4. - Table H.3.1-3 is used with associated condition SSB.1 RedCap FR1 for test configuration 16.7.1.2.1-3
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.1.5 Test requirement
Table 16.7.1.2.1.5-1 defines the primary level settings including test tolerances for all tests. Each SS-RSRP measurement report for each of the tests in Table 16.7.1.2.1.5-1 shall meet the corresponding absolute accuracy requirements in Table 16.7.1.2.1.5-2 for test configurations 1, 2 and 4 and the corresponding abso...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2 NR SA FR1 SS-RSRP relative measurement accuracy for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2.1 Test purpose
The purpose of this test is to verify that the intra-frequency SS-RSRP relative measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2.2 Test applicability
This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.1.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.1.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.7.1.2.2.4.1-1. Table 16.7.1.2.2.4.1-1: NR SA FR1 SS-RSRP measurement accuracy supported test configurations Test Case ID Description 16.7.1.2.2-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.7.1.2.2-2 NR 15 kHz SSB SCS, 10 MHz bandwid...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.1.2.4.2 with following exceptions: - Table 6.7.1.1.2.5-1 is replaced by Table 16.7.1.2.2.5-1. - Table 6.7.1.1.2.5-2 is replaced by Table 16.7.1.2.2.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2.4.3 Message contents
Message contents are same as in clause 16.7.1.2.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.2.2.5 Test requirement
Table 16.7.1.2.2.5-1 defines the primary level settings including test tolerances for all tests. Each SS-RSRP measurement report for each of the tests in Table 16.7.1.2.2.5-1 shall meet the corresponding relative accuracy requirements in Table 16.7.1.2.2.5-2. Table 16.7.1.2.2.5-1: Same as Table 16.7.1.2.1.5-1 with the ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3 Inter-frequency measurements for RedCap for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1 NR SA FR1-FR1 SS-RSRP absolute measurement accuracy for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-RSRP absolute measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1.2 Test applicability
This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.1.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.1.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.7.1.3.1.4.1-1. Table 16.7.1.3.1.4.1-1: NR SA FR1 SS-RSRP measurement accuracy supported test configurations Test Case ID Description 16.7.1.3.1-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.7.1.3.1-2 NR 15 kHz SSB SCS, 10 MHz bandwid...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.2.1.4.2 with following exceptions: - Table 6.7.1.2.1.5-1 is replaced by Table 16.7.1.3.1.5-1. - Table 6.7.1.2.1.5-2 is replaced by Table 16.7.1.3.1.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1.4.3 Message contents
Same as the message contents given in clause 6.7.1.2.1.4.3 with following exceptions: - Specific message contents exceptions for test configuration 6.7.1.2.1-1 applies to test configuration 16.7.2.2-4. - Table H.3.1-3 is used with associated condition SSB.1 RedCap FR1 for test configuration 16.7.1.3.1-3
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.1.5 Test requirement
Table 16.7.1.3.1.5-1 defines the primary level settings including test tolerances for all tests. Each SS-RSRP measurement report for each of the tests in Table 16.7.1.3.1.5-1 shall meet the corresponding absolute accuracy requirements in Table 16.7.1.3.1.5-2 for test configurations 1, 2 and 4 and the corresponding abso...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2 NR SA FR1-FR1 SS-RSRP relative measurement accuracy for 1 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-RSRP relative measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2.2 Test applicability
This test applies to all types of NR RedCap UE with 1 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.1.0.4. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.1.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.7.1.3.2.4.1-1. Table 16.7.1.3.2.4.1-1: NR SA FR1 SS-RSRP measurement accuracy supported test configurations Test Case ID Description 16.7.1.3.2-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.7.1.3.2-2 NR 15 kHz SSB SCS, 10 MHz bandwid...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.2.2.4.2 with following exceptions: - Table 6.7.1.2.2.5-1 is replaced by Table 16.7.1.3.2.5-1. - Table 6.7.1.2.2.5-2 is replaced by Table 16.7.1.3.2.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2.4.3 Message contents
Message contents are same as in clause 16.7.1.3.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.3.2.5 Test requirement
Table 16.7.1.3.2.5-1 defines the primary level settings including test tolerances for all tests. Each SS-RSRP measurement report for each of the tests in Table 16.7.1.3.2.5-1 shall meet the corresponding relative accuracy requirements in Table 16.7.1.3.2.5-2. Table 16.7.1.3.2.5-1: Same as Table 16.7.1.3.1.5-1 Table 16....
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4 Inter-frequency measurements for RedCap for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1 NR SA FR1-FR1 SS-RSRP absolute measurement accuracy for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-RSRP absolute measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1.2 Test applicability
This test applies to all types of NR RedCap UE with 2 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.1.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.1.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.7.1.4.1.4.1-1. Table 16.7.1.4.1.4.1-1: NR SA FR1 SS-RSRP measurement accuracy supported test configurations Test Case ID Description 16.7.1.4.1-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.7.1.4.1-2 NR 15 kHz SSB SCS, 10 MHz bandwid...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.2.1.4.2 with following exceptions: - Table 6.7.1.2.1.5-1 is replaced by Table 16.7.1.4.1.5-1. - Table 6.7.1.2.1.5-2 is replaced by Table 16.7.1.4.1.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1.4.3 Message contents
Same as the message contents given in clause 6.7.1.2.1.4.3 with following exceptions: - Specific message contents exceptions for test configuration 6.7.1.2.1-1 applies to test configuration 16.7.1.4.1-4. - Table H.3.1-3 is used with associated condition SSB.1 RedCap FR1 for test configuration 16.7.1.4.1-3
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.1.5 Test requirement
Table 16.7.1.4.1.5-1 defines the primary level settings including test tolerances for all tests. Each SS-RSRP measurement report for each of the tests in Table 16.7.1.4.1.5-1 shall meet the corresponding absolute accuracy requirements in Table 16.7.1.4.1.5-2 for test configurations 1, 2 and 4 and the corresponding abso...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2 NR SA FR1-FR1 SS-RSRP relative measurement accuracy for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-RSRP relative measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2.2 Test applicability
This test applies to all types of NR RedCap UE with 2 Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 16.7.1.0.4. The normative reference for this requirement is TS 38.133 [6] clause A.16.7.1.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 16.7.1.4.2.4.1-1. Table 16.7.1.4.2.4.1-1: NR SA FR1 SS-RSRP measurement accuracy supported test configurations Test Case ID Description 16.7.1.4.2-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode 16.7.1.4.2-2 NR 15 kHz SSB SCS, 10 MHz bandwid...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.2.2.4.2 with following exceptions: - Table 6.7.1.2.2.5-1 is replaced by Table 16.7.1.4.2.5-1. - Table 6.7.1.2.2.5-2 is replaced by Table 16.7.1.4.2.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2.4.3 Message contents
Message contents are same as in clause 16.7.1.4.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.1.4.2.5 Test requirement
Table 16.7.1.4.2.5-1 defines the primary level settings including test tolerances for all tests. Each SS-RSRP measurement report for each of the tests in Table 16.7.1.4.2.5-1 shall meet the corresponding relative accuracy requirements in Table 16.7.1.4.2.5-2. Table 16.7.1.4.2.5-1: Same as Table 16.7.1.4.1.5-1 Table 16....
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.2 SS-RSRQ for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.2.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.2.0.1 Intra-frequency SS-RSRQ measurement accuracy requirements
When RedCap UE is capable of 2Rx, the minimum requirements given in clause 4.7.2.0.1 shall apply. When RedCap UE is only required to support 1Rx, the absolute accuracy requirements in Table 16.7.2.0.1-1 are valid under the following conditions: - Conditions defined in clause 7.3 of TS 38.101-1 [2] for reference sensiti...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
16.7.2.0.2 Inter-frequency SS-RSRQ absolute measurement accuracy requirements
When RedCap UE is capable of 2Rx, the minimum requirements given in clause 4.7.2.0.2 shall apply. When RedCap UE is only required to support 1Rx, the absolute accuracy requirements in Table 16.7.2.0.2-1 are valid under the following conditions: - Conditions defined in clause 7.3I of TS 38.101-1 [2] for reference sensit...