hash
stringlengths
32
32
doc_id
stringlengths
5
12
section
stringlengths
5
1.47k
content
stringlengths
0
6.67M
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2 SS-RSRQ for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.0.1 Intra-frequency SS-RSRQ measurement accuracy requirements
Same as in clause 5.7.1.0.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.0.2 Inter-frequency SS-RSRQ measurement accuracy requirements
Same as in clause 5.7.1.0.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.1 NR SA FR2 SS-RSRQ measurement accuracy for 2 Rx UE
Editor’s Note: This test case has been completed for the following configurations: - Test frequency f ≤ 40.8 GHz - UE PC3 - Normal conditions - The test is incomplete for UE power classes other than PC3 - The test is incomplete for test frequencies > 40.8 GHz - The test is incomplete for extreme conditions17.7.2.1.1 Te...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.1.2 Test applicability
This test applies to all types of NR RedCap UE from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 17.7.2.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.17.7.2.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.1.4 Test description
Same as the test description given in clause 7.7.2.1.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.1.4.1 Initial conditions
Same as the initial conditions given in clause 7.7.2.1.4.1 with following exceptions: • Table 7.7.2.1.4.1-1 is replaced by Table 17.7.2.1.4.1-1; • Table 7.7.2.1.4.1-2 is replaced by Table 17.7.2.1.4.1-2; Table 17.7.2.1.4.1-1: Supported test configurations Configuration Description 17.7.2.1-1 120 kHz SSB SCS, 100 MHz ba...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.1.4.2 Test procedure
Same as the test procedure given in clause 7.7.2.1.4.2 with following exceptions: - Table 7.7.2.1.5-1 is replaced by Table 17.7.2.1.5-1; - Table 7.7.2.1.5-2 is replaced by Table 17.7.2.1.5-2; - Table 7.7.2.1.5-3 is replaced by Table 17.7.2.1.5-3;
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.1.4.3 Message contents
Same as the message contents given in clause 7.7.2.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.1.5 Test requirement
Same as the test requirements given in clause 7.7.2.1.5 with followings exceptions: - Table 7.7.2.1.5-1 is replaced by Table 17.7.2.1.5-1; - Table 7.7.2.1.5-2 is replaced by Table 17.7.2.1.5-2; - Table 7.7.2.1.5-3 is replaced by Table 17.7.2.1.5-3; Table 17.7.2.1.5-1: Cell-specific test parameters Parameter Unit Cell 1...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.2 NR SA FR2-FR2 SS-RSRQ measurement accuracy for 2 Rx UE
Editor’s Note: This test case has been completed for the following configurations: - Test frequency f ≤ 40.8 GHz - UE PC3 - Normal conditions - The test is incomplete for UE power classes other than PC3 - The test is incomplete for test frequencies > 40.8 GHz - The test is incomplete for extreme conditions17.7.2.2.1 Te...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.2.2 Test applicability
This test applies to all types of NR RedCap UE from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 17.7.2.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.17.7.2.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.2.4 Test description
Same as the test description given in clause 7.7.2.2.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.2.4.1 Initial conditions
Same as the initial conditions given in clause 7.7.2.2.4.1 with following exceptions: • Table 7.7.2.2.4.1-1 is replaced by Table 17.7.2.2.4.1-1; • Table 7.7.2.2.4.1-2 is replaced by Table 17.7.2.2.4.1-2; Table 17.7.2.2.4.1-1: Supported test configurations Configuration Description 17.7.2.2-1 120 kHz SSB SCS, 100 MHz ba...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.2.4.2 Test procedure
Same as the test procedure given in clause 7.7.2.2.4.2 with following exceptions: - Table 7.7.2.2.5-1 is replaced by Table 17.7.2.2.5-1; - Table 7.7.2.2.5-2 is replaced by Table 17.7.2.2.5-2; - Table 7.7.2.2.5-3 is replaced by Table 17.7.2.2.5-3; - Table 7.7.2.2.5-4 is replaced by Table 17.7.2.2.5-4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.2.4.3 Message contents
Same as the message contents given in clause 7.7.2.2.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.2.2.5 Test requirement
Same as the test requirements given in clause 7.7.2.2.5 with followings exceptions: - Table 7.7.2.2.5-1 is replaced by Table 17.7.2.2.5-1; - Table 7.7.2.2.5-2 is replaced by Table 17.7.2.2.5-2; - Table 7.7.2.2.5-3 is replaced by Table 17.7.2.2.5-3; - Table 7.7.2.2.5-4 is replaced by Table 17.7.2.2.5-4. Table 17.7.2.2.5...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3 L1-RSRP measurement for beam reporting for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.0.1 SSB-based L1-RSRP absolute measurement accuracy requirements
Same as in clause 5.7.4.0.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.0.2 SSB-based L1-RSRP relative measurement accuracy requirements
Same as in clause 5.7.4.0.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.0.3 CSI-RS-based L1-RSRP absolute measurement accuracy requirements
Same as in clause 5.7.4.0.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.0.4 CSI-RS-based L1-RSRP relative measurement accuracy requirements
Same as in clause 5.7.4.0.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.1 NR SA FR2 SSB based L1-RSRP measurement accuracy for 2 Rx UE
Editor's Note: This test case has been completed for the following configurations: - Test frequency f ≤ 40.8 GHz - UE PC3 - Normal conditions - The test is incomplete for UE power classes other than PC3 - The test is incomplete for test frequencies > 40.8 GHz - The test is incomplete for extreme conditions17.7.3.1.1 Te...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.1.2 Test applicability
This test applies to all types of NR RedCap UE from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 17.7.3.0.1 and 17.7.3.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.17.7.3.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.1.4.1 Initial conditions
Same as the initial conditions given in clause 7.7.4.1.4.1 with following aspects: • Table 7.7.4.1.4.1-1 is replaced by Table 17.7.3.1.4.1-1; • Table 7.7.4.1.4.1-2 is replaced by Table 17.7.3.1.4.1-2; Table 17.7.3.1.4.1-1: Supported test configurations Test Case ID Description 17.7.3.1-1 NR 120 kHz SSB SCS, 100 MHz ban...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.1.4.2 Test procedure
Same as the test procedure given in clause 7.7.4.1.4.2 with following aspects: • Table 7.7.4.1.5-1 is replaced by Table 17.7.3.1.5-1; • Table 7.7.4.1.5-2 is replaced by Table 17.7.3.1.5-2; • Table 7.7.4.1.5-3 is replaced by Table 17.7.3.1.5-3; • Table 7.7.4.1.5-3a is replaced by Table 17.7.3.1.5-4; • Table 7.7.4.1.5-3b...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.1.4.3 Message contents
Same as the message contents given in clause 7.7.4.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.1.5 Test requirement
Same as the test requirements given in clause 7.7.4.1.5 with following aspects: • Table 7.7.4.1.5-1 is replaced by Table 17.7.3.1.5-1; • Table 7.7.4.1.5-2 is replaced by Table 17.7.3.1.5-2; • Table 7.7.4.1.5-3 is replaced by Table 17.7.3.1.5-3; • Table 7.7.4.1.5-3a is replaced by Table 17.7.3.1.5-4; • Table 7.7.4.1.5-3...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.2 NR SA FR2 CSI-RS based L1-RSRP measurement accuracy for 2 Rx UE
Editor's Note: This test case has been completed for the following configurations: - Test frequency f ≤ 40.8 GHz - UE PC3 - Normal conditions - The test is incomplete for UE power classes other than PC3 - The test is incomplete for test frequencies > 40.8 GHz - The test is incomplete for extreme conditions17.7.3.2.1 Te...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.2.2 Test applicability
This test applies to all types of NR RedCap UE from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 17.7.3.0.3 and 17.7.3.0.4. The normative reference for this requirement is TS 38.133 [6] clause A.17.7.3.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.2.4.1 Initial conditions
Same as the initial conditions given in clause 7.7.4.2.4.1 with following aspects: • Table 7.7.4.2.4.1-1 is replaced by Table 17.7.3.2.4.1-1; • Table 7.7.4.2.4.1-2 is replaced by Table 17.7.3.2.4.1-2; Table 17.7.3.2.4.1-1: Supported test configurations Test Case ID Description 17.7.3.2-1 NR 120 kHz SSB SCS, 100 MHz ban...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.2.4.2 Test procedure
Same as the test procedure given in clause 7.7.4.2.4.2 with following aspects: • Table 7.7.4.2.5-1 is replaced by Table 17.7.3.2.5-1; • Table 7.7.4.2.5-2 is replaced by Table 17.7.3.2.5-2; • Table 7.7.4.2.5-3 is replaced by Table 17.7.3.2.5-3; • Table 7.7.4.2.5-3a is replaced by Table 17.7.3.2.5-4; • Table 7.7.4.2.5-3b...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.2.4.3 Message contents
Same as the message contents given in clause 7.7.4.2.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.3.2.5 Test requirement
Same as the test requirements given in clause 7.7.4.2.5 with following aspects: • Table 7.7.4.2.5-1 is replaced by Table 17.7.3.2.5-1; • Table 7.7.4.2.5-2 is replaced by Table 17.7.3.2.5-2; • Table 7.7.4.2.5-3 is replaced by Table 17.7.3.2.5-3; • Table 7.7.4.2.5-3a is replaced by Table 17.7.3.2.5-4; • Table 7.7.4.2.5-3...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4 SS-SINR for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.0.1 Intra-frequency SS-SINR measurement accuracy requirements
Same as in clause 5.7.3.0.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.0.2 Inter-frequency SS-SINR measurement accuracy requirements
Same as in clause 5.7.3.0.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.1 NR SA FR2 SS-SINR measurement accuracy for 2 Rx UE
Editor’s Note: This test case has been completed for the following configurations: - Test frequency f ≤ 40.8 GHz - UE PC3 - Normal conditions - The test is incomplete for UE power classes other than PC3 - The test is incomplete for test frequencies > 40.8 GHz - The test is incomplete for extreme conditions17.7.4.1.1 Te...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.1.2 Test applicability
This test applies to all types of NR RedCap UE from Release 17 onwards and supporting SS-SINR measurements.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 17.7.4.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.17.7.4.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.1.4 Test description
Same as the test description given in clause 7.7.3.1.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.1.4.1 Initial conditions
Same as the initial conditions given in clause 7.7.3.1.4.1 with following exceptions: • Table 7.7.3.1.4.1-1 is replaced by Table 17.7.4.1.4.1-1; • Table 7.7.3.1.4.1-2 is replaced by Table 17.7.4.1.4.1-2; Table 17.7.4.1.4.1-1: Supported test configurations Configuration Description 17.7.4.1-1 NR 120 kHz SSB SCS, 100 MHz...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.1.4.2 Test procedure
Same as the test procedure given in clause 7.7.3.1.4.2 with following exceptions: - Table 7.7.3.1.5-1 is replaced by Table 17.7.4.1.5-1; - Table 7.7.3.1.5-2 is replaced by Table 17.7.4.1.5-2; - Table 7.7.3.1.5-3 is replaced by Table 17.7.4.1.5-3;
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.1.4.3 Message contents
Same as the message contents given in clause 7.7.3.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.1.5 Test requirement
Same as the test requirement given in clause 7.7.3.1.5 with following exceptions: - Table 7.7.3.1.5-1 is replaced by Table 17.7.4.1.5-1; - Table 7.7.3.1.5-2 is replaced by Table 17.7.4.1.5-2; - Table 7.7.3.1.5-3 is replaced by Table 17.7.4.1.5-3; Table 17.7.4.1.5-1: Cell-specific test parameters Parameter Unit Cell 1 C...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2 NR SA FR2-FR2 SS-SINR measurement accuracy for 2 Rx UE
Editor’s Note: This test case has been completed for the following configurations: - Test frequency f ≤ 40.8 GHz - UE PC3 - Normal conditions - The test is incomplete for UE power classes other than PC3 - The test is incomplete for test frequencies > 40.8 GHz - The test is incomplete for extreme conditions
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-SINR measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2.2 Test applicability
This test applies to all types of NR RedCap UE from Release 17 onwards and supporting SS-SINR measurements.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 17.7.4.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.17.7.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2.4 Test description
Same as the test description given in clause 7.7.3.2.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2.4.1 Initial conditions
Same as the initial conditions given in clause 7.7.3.2.4.1 with following exceptions: • Table 7.7.3.2.4.1-1 is replaced by Table 17.7.4.2.4.1-1; • Table 7.7.3.2.4.1-2 is replaced by Table 17.7.4.2.4.1-2; Table 17.7.4.2.4.1-1: Supported test configurations Configuration Description 17.7.4.2-1 NR 120 kHz SSB SCS, 100 MHz...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2.4.2 Test procedure
Same as the test procedure given in clause 7.7.3.2.4.2 with following exceptions: - Table 7.7.3.2.5-1 is replaced by Table 17.7.4.2.5-1; - Table 7.7.3.2.5-2 is replaced by Table 17.7.4.2.5-2; - Table 7.7.3.2.5-3 is replaced by Table 17.7.4.2.5-3; - Table 7.7.3.2.5-4 is replaced by Table 17.7.4.2.5-4;
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2.4.3 Message contents
Same as the message contents given in clause 7.7.3.2.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
17.7.4.2.5 Test requirement
Same as the test requirement given in clause 7.7.3.2.5 with following exceptions: - Table 7.7.3.2.5-1 is replaced by Table 17.7.4.2.5-1; - Table 7.7.3.2.5-2 is replaced by Table 17.7.4.2.5-2; - Table 7.7.3.2.5-3 is replaced by Table 17.7.4.2.5-3; - Table 7.7.3.2.5-4 is replaced by Table 17.7.4.2.5-4; Table 17.7.4.2.5-1...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18 E-UTRA - NR inter-RAT with E-UTRA serving cell for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1 RRC_IDLE state mobility for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1 Inter-RAT cell re-selection for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.0 Minimum conformance requirements
TBD
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1 E-UTRA - NR SA FR1 E-UTRA cell re-selection to higher priority NR target Cell for 2 Rx UE
Editor's Note: This test case is incomplete in following aspects: - Message contents are missing. - Test procedure is TBD - Test applicability is missing - Cell mapping is missing
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1.1 Test purpose
The purpose of this test is to verify the requirement for the E-UTRA - NR SA FR1 inter-RAT cell reselection for RedCap UEs. The requirements are specified in TS 38.133 [6] in clause TBD.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1.2 Test applicability
This test applies to all types of NR RedCap UE release 17 and forward.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1.3 Minimum conformance requirements
The minimum conformance requirements are defined in clause 18.1.1.0.x. The normative reference for this requirement is TS 38.133 [6] clause A.18.1.1.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1.4.1 Initial conditions
This test shall be tested using any of the test configurations in Table 18.1.1.1.4.1-1. Table 18.1.1.1.4.1-1: Supported test configurations for E-UTRA - NR SA FR1 E-UTRA Cell reselection to higher priority NR target Cell in FR1 Configuration Description 18.1.1.1-1 LTE FDD, NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duple...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1.4.2 Test procedure
TBD
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1.4.3 Message contents
Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions: TBD
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.1.1.1.5 Test requirement
Table 18.1.1.1.5-1 defines the primary level settings including test tolerances for NR – E-UTRA cell re-selection test case in AWGN for 2 Rx UE. Table 18.1.1.1.5-1: NR cell 2 specific test parameters for E-UTRA - NR SA FR1 E-UTRA Cell reselection to higher priority NR target Cell in FR1 Parameter Unit Test configuratio...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2 RRC_CONNECTED state mobility for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1 Handover for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.0 Minimum conformance requirements
Then minimum requirements given in clause 16.3.1.0.2 apply. The normative reference for this requirement is TS 36.133 [23] clause 5.3.4B.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1 E-UTRA - NR SA FR1 handover for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1.1 Test purpose
To verify the E-UTRAN to NR FR1 handover requirements for 2RX RedCap as specified in TS 36.133 [23] clause 5.3.4B.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1.2 Test applicability
This test applies to all E-UTRA UE from release 17 onwards and capable of NR RedCap with 2Rx.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1.3 Minimum conformance requirements
The minimum conformance requirements are defined in clause 18.2.1.0 The normative reference for this requirement is TS 38.133 [6] clause A.18.2.1.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1.4 Test description
Same as the test description given in clause 8.3.1.1.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1.4.1 Initial conditions
Same as the initial conditions given in clause 8.3.1.1.4.1 with following exceptions: - Table 8.3.1.1.4.1-1 is replaced by Table 18.2.1.1.4.1-1. - Table 8.3.1.1.4.1-2 is replaced by Table 18.2.1.1.4.1-2. - Table 8.3.1.1.4.1-3 is replaced by Table 18.2.1.1.4.1-3. Table 18.2.1.1.4.1-1: Supported test configurations Confi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1.4.2 Test procedure
Same as the test procedure given in clause 8.3.1.1.4.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1.4.3 Message contents
Same as the message contents given in clause 8.3.1.1.4.3 with following exceptions. - Table 7.3.1-3 in TS 38.508-1 [14] is used with condition SMTC.1 RedCap.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.1.1.5 Test requirement
Same as the test requirements given in clause 8.3.1.1.5 with following exceptions: - Table 8.3.1.1.5-1 is replaced by Table 18.2.1.1.5-1. - Table 8.3.1.1.5-2 is replaced by Table 18.2.1.1.5-2. Table 18.2.1.1.5-1: Cell specific test parameters for E-UTRA PCell (Cell 1) Parameter Unit Configuration Cell 1 T1 T2 T3 RF cha...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2 RRC connection release with redirection for RedCap
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.0.1 Redirection from E-UTRA to FR1 RedCap UE
The RedCap UE shall be capable of performing the RRC connection release with redirection to the target NR cell within Tconnection_release_redirect_NR_RedCap. The time delay (Tconnection_release_redirect_NR_RedCap) is the time between the end of the last TTI containing the RRC command, “RRCConnectionRelease” (TS 36.331 ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1 E-UTRA - NR SA FR1 RRC connection release with redirection for 2 Rx UE
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1.1 Test purpose
To verify RRC connection release with redirection from E-UTRA to NR requirements for 2Rx RedCap specified in 36.133 [23] clause 6.3.2.6.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1.2 Test applicability
This test applies to all types of NR RedCap UE with 2Rx from Release 17 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1.3 Minimum conformance requirement
The minimum conformance requirements are specified in clause 18.2.2.0.1. The normative reference for this requirement is TS 38.133 [6] clauses A.18.2.2.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1.4.1 Initial conditions
This test can be run in the configurations defined in Table 18.2.2.1.4.1-1 Table 18.2.2.1.4.1-1: Supported test configurations Configuration Description 18.2.2.1-1 NR 15 kHz SSB SCS, 10 MHz bandwidth, FDD duplex mode, LTE FDD 18.2.2.1-2 NR 15 kHz SSB SCS, 10 MHz bandwidth, TDD duplex mode, LTE FDD 18.2.2.1-3 NR 30 kHz ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1.4.2 Test procedure
The test consists of two successive time periods, with time duration of T1, and T2 respectively. The RRCConnectionRelease message shall be sent to the UE during period T1 and the start of T2 is the instant when the last TTI containing the RRC message is sent to the UE. Prior to time duration T2, the UE shall not have a...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1.4.3 Message contents
Message contents are according to TS 38.508-1 [14] clause 7.3 with the following exceptions: Table 18.2.2.1.4.3-1: RRCConnectionRelease (Test procedure, Step 3) Derivation Path: 36.508 [25] Table 4.6.1-15 Information Element Value/remark Comment Condition RRCConnectionRelease ::= SEQUENCE { criticalExtensions CHOICE { ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
18.2.2.1.5 Test requirement
Table 18.2.2.1.4.3-1 and Table 18.2.2.1.4.3-2 define the primary level settings for redirection from E-UTRA to NR RedCap test case. Table 18.2.2.1.5-1: E-UTRA Cell specific test parameters (Cell 1) Parameter Unit Configuration Cell 1 T1 T2 RF channel number 1,2,3,4,5,6,7,8 2 Duplex mode 1,2,3,7 FDD 4,5,6,8 TDD TDD spec...