hash stringlengths 32 32 | doc_id stringlengths 5 12 | section stringlengths 5 1.47k | content stringlengths 0 6.67M |
|---|---|---|---|
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.89 DC_2A-48A-66A_n71A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.89.1 Operating bands for DC | Table 5.1.89.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-48-66_n71
CA_2-48-66
n71
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.89.2 Configuration for DC | Table 5.1.89.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-48A-66A_n71A
DC_2A_n71A
DC_48A_n71A
DC_66A_n71A
CA_2A-48A-66A
n71A
5.1.89.3 ∆TIB and ∆RIB values
For DC_2-48-66_n71 the TIB,c and RIB,c value... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.89.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.90 DC_5A-48A-66A_n71A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.90.1 Operating bands for DC | Table 5.1.90.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_5-48-66_n71
CA_5-48-66
n71
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.90.2 Configuration for DC | Table 5.1.90.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_5A-48A-66A_n71A
DC_5A_n71A
DC_48A_n71A
DC_66A_n71A
CA_5A-66A-481A
n71A
5.1.90.3 ∆TIB and ∆RIB values
For DC_5-48-66_n71 the TIB,c and RIB,c valu... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.90.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.91 DC_2A-5A-48A_n71A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.91.1 Operating bands for DC | Table 5.1.91.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-5-48_n71
CA_2-5-48
n71
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.91.2 Configuration for DC | Table 5.1.91.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-5A-48A_n71A
DC_2A_n71A
DC_5A_n71A
DC_48A_n71A
CA_2A-5A-48A
n71A
5.1.91.3 ∆TIB and ∆RIB values
For DC_2-5-48_n71 the TIB,c and RIB,c values ar... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.91.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.92 DC_2A-5A-66A_n71A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.92.1 Operating bands for DC | Table 5.1.92.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-5-66_n71
CA_2-5-66
n71
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.92.2 Configuration for DC | Table 5.1.92.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-5A-66A_n71A
DC_2A_n71A
DC_5A_n71A
DC_66A_n71A
CA_2A-5A-66A
n71A
5.1.92.3 ∆TIB and ∆RIB values
For DC_2-5-66_n71 the TIB,c and RIB,c values ar... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.92.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.93 DC_2A-48A-66A_n12A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.93.1 Operating bands for DC | Table 5.1.93.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-48-66_n12
CA_2-48-66
n12
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.93.2 Configuration for DC | Table 5.1.93.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-48A-66A_n12A
DC_2A_n12A
DC_48A_n12A
DC_66A_n12A
CA_2A-48A-66A
n12A
5.1.93.3 ∆TIB and ∆RIB values
For DC_2-48-66_n12 the TIB,c and RIB,c value... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.93.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.94 DC_48A-66A-(n)12AA | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.94.1 Operating bands for DC | Table 5.1.94.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_48-66-(n)12
CA_12-48-66
n12
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.94.2 Configuration for DC | Table 5.1.94.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_48A-66A-(n)12AA
DC_(n)12AA1
DC_48A_n12A
DC_66A_n12A
CA_12A-48A-66A
n12A
NOTE 1: Only single switched UL is supported
5.1.94.3 ∆TIB and ∆RIB values... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.94.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.95 DC_2A-48A-(n)12AA | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.95.1 Operating bands for DC | Table 5.1.95.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-48-(n)12
CA_2-12-48
n12
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.95.2 Configuration for DC | Table 5.1.95.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-48A-(n)12AA
DC_2A_n12A
DC_(n)12AA1
DC_48A_n12A
CA_2A-12A-48A
n12A
NOTE 1: Only single switched UL is supported
5.1.95.3 ∆TIB and ∆RIB values
Fo... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.95.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.96 DC_2A-12A-66A_n12AA | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.96.1 Operating bands for DC | Table 5.1.96.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-66-(n)12
CA_2-12-66
n12
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.96.2 Configuration for DC | Table 5.1.96.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-66A-(n)12AA
DC_2A_n12A
DC_(n)12AA1
DC_66A_n12A
CA_2A-12A-66A
n12A
NOTE 1: Only single switched UL is supported
5.1.96.3 ∆TIB and ∆RIB values
Fo... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.96.4 REFSENS requirements | No further MSD are needed to be specified.
5.1.97 DC_1-3-20_n41 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.97.1 Operating bands for EN-DC | Table 5.1.97.1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-20_n41
CA_1-3-20
n41
DC_20A_n41A
5.1.97.2 Configuration for EN-DC
Table 5.1.97.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA CA configuration
NR band... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.97.4 REFSENS requirements | No additional MSD requirement is observed. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.98 DC_1-7-28_n40 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.98.1 Operating bands for DC | Table 5.1.98.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-7-28_n40
CA_1-7-28
n40
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.98.2 Configuration for DC | Table 5.1.98.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_1A-7A-28A_n40A
DC_1A_n40A
DC_7A_n40A
DC_28A_n40A
CA_1A-7A-28A
n40A
5.1.98.3 ∆TIB and ∆RIB values
For DC_1-7-28_n40, the TIB,c and RIB,c values are used from CA_1-7-28-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.99 DC_1-3-7_n40 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.99.1 Operating bands for DC | Table 5.1.99.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-7_n40
CA_1-3-7
n40
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.99.2 Configuration for DC | Table 5.1.99.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_1A-3A-7A_n40A
DC_1A_n40A
DC_3A_n40A
DC_7A_n40A
CA_1A-3A-7A
n40A
5.1.99.3 ∆TIB and ∆RIB values
For DC_1-3-7_n40, the TIB,c and RIB,c values are used from CA_1-3-7-40 in... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.100 DC_3-7-28_n40 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.100.1 Operating bands for DC | Table 5.1.100.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_3-7-28_n40
CA_3-7-28
n40
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.100.2 Configuration for DC | Table 5.1.100.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_3A-7A-28A_n40A
DC_3A_n40A
DC_7A_n40A
DC_28A_n40A
CA_3A-7A-28A
n40A
5.1.100.3 ∆TIB and ∆RIB values
For DC_3-7-28_n40, the TIB,c and RIB,c values are used from CA_3-7-2... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.101 DC_1A-3A-28A_n40A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.101.1 Operating bands for DC | Table 5.1.101.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-28_n40
CA_1-3-28
n40
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.101.2 Configuration for DC | Table 5.1.101.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3A-28A_n40A
DC_1A_n40A
DC_3A_n40A
DC_28A_n40A
CA_1A-3A-28A
n40A
5.1.101.3 ∆TIB and ∆RIB values
For DC_1-3-28_n40 the TIB,c and RIB,c values ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.101.4 REFSENS requirements | No further MSD are needed to be specified.
5.1.102 DC_2-5_(n)12 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.102.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-5_(n)12
CA_2-5-12
n12 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.102.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-5A_(n)12AA
DC_5A_n12A
DC_2A_n12A
DC_(n)12AA1
CA_2A-5A-12A
n12
NOTE1: Only single switched UL is supported
5.1.102.3 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.3-1: ΔTIB... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.103.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-12_(n)5
CA_2-5-12
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.103.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-12A_(n)5AA
DC_2A_n5A
DC_12A_n5A
DC_(n)5AA1
CA_2A-5A-12A
n5
NOTE1: Only single switched UL is supported
5.1.103.3 ∆TIB and ∆RIB values
Based on CA_2-5-12 following ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.104.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-48_(n)5
CA_2-5-48
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.104.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-48A_(n)5AA
DC_2A_n5A
DC_48A_n5A
DC_(n)5AA1
CA_2A-5A-48A
n5
NOTE 1: Only single switched UL is supported
5.1.104.3 ∆TIB and ∆RIB values
Based on CA_2-48 and CA_2-5 ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.105.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-66_(n)5
CA_2-5-66
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.105.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-66A_(n)5AA
DC_2A_n5A
DC_66A_n5A
DC_(n)5AA1
CA_2A-5A-66A
n5
NOTE 1: Only single switched UL is supported
5.1.105.3 ∆TIB and ∆RIB values
Based on CA_2-5-66 following... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.106.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_5-48_(n)12
CA_5-12-48
n12 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.106.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
C_5A-48A_(n)12AA
DC_5A_n12A
DC_48A_n12A
DC_(n)12AA1
CA_5A-12A-48A
n12
NOTE1: Only single switched UL is supported
5.1.106.3 ∆TIB and ∆RIB values
Based on CA_5-12-48follo... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.107.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_5-66_(n)12
CA_5-12-66
n12 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.107.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_5A-66A_(n)12AA
DC_5A_n12A
DC_66A_n12A
DC_(n)12AA1
CA_5A-12A-66A
n12
NOTE1: Only single switched UL is supported
5.1.107.3 ∆TIB and ∆RIB values
Based on CA_5-12-66 fol... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.108.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_12-48_(n)5
CA_5-12-48
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.108.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_12A-48A_(n)5AA
DC_12A_n5A
DC_48A_n5A
DC_(n)5AA1
CA_5A-12A-48A
n5
NOTE1: Only single switched UL is supported
5.1.108.3 ∆TIB and ∆RIB values
Based on CA_5-12-48 follow... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.109.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_12-66_(n)5
CA_5-12-66
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.109.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_12A-66A_(n)5AA
DC_12A_n5A
DC_66A_n5A
DC_(n)5AA1
CA_5A-12A-66A
n5
NOTE1: Only single switched UL is supported
5.1.109.3 ∆TIB and ∆RIB values
Based on CA_5-12-66 follow... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.110 DC_1-11-18_n77 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.110.1 Operating bands for DC | Table 5.1.110.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-11-18_n77
DC_1-11-18
n77
Yes |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.110.2 Configurations for DC | Table 5.1.110.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-11A-18A_n77A
DC_1A_n77A
DC_11A_n77A
DC_18A_n77A
CA_1A-11A-18A
n77
5.1.110.3 ∆TIB and ∆RIB values
Table 5.1.110.3-1: ΔTIB,c due to EN-DC(four bands)
Inter-b... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.110.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.111 DC_1-11-18_n78 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.111.1 Operating bands for DC | Table 5.1.111.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-11-18_n78
DC_1-11-18
n78
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.111.2 Configurations for DC | Table 5.1.111.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-11A-18A_n78A
DC_1A_n78A
DC_11A_n78A
DC_18A_n78A
CA_1A-11A-18A
n78
5.1.111.3 ∆TIB and ∆RIB values
Table 5.1.111.3-1: ΔTIB,c due to EN-DC(four bands)
Inter-b... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.111.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.112 DC_1-18-41_n3 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.112.1 Operating bands for DC | Table 5.1.112.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-18-41_n3
DC_1-18-41
n3
Yes |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.112.2 Configurations for DC | Table 5.1.112.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-18A-41A_n3A
DC_1A-18A-41C_n3A
DC_1A_n3A
DC_18A_n3A
DC_41A_n3A
DC_41C_n3A
CA_1A-18A-41A
CA_1A-18A-41C
n3
5.1.112.3 ∆TIB and ∆RIB values
Table 5.1.112.3-1: Δ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.112.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.113 DC_1-18-41_n77 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.113.1 Operating bands for DC | Table 5.1.113.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-18-41_n77
CA_1-18-41
n77
Yes |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.113.2 Configurations for DC | Table 5.1.113.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-18A-41A_n77A
DC_1A-18A-41C_n77A
DC_1A_n77A
DC_18A_n77A
DC_41A_n77A
DC_41C_n77A
CA_1A-18A-41A
CA_1A-18A-41C
n77
5.1.113.3 ∆TIB and ∆RIB values
Table 5.1.113... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.113.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.114 DC_1-18-41_n78 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.114.1 Operating bands for DC | Table 5.1.114.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-18-41_n78
CA_1-18-41
n78
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.114.2 Configurations for DC | Table 5.1.114.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-18A-41A_n78A
DC_1A-18A-41C_n78A
DC_1A_n78A
DC_18A_n78A
DC_41A_n78A
DC_41C_n78A
CA_1A-18A-41A
CA_1A-18A-41C
n78
5.1.114.3 ∆TIB and ∆RIB values
Table 5.1.114... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.114.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.115 DC_2-29-66_n66 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.115.1 Operating bands for EN-DC | Table 5.1.115.1-1: Band combinations EN-DC (three bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-29-66_n66
CA_2-29-66
n66 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.115.2 Configuration for DC | Table 5.1.115.2-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-29A-66A_n66A
DC_2A_n66A
DC_66A_n66A1
CA_2A-29A-66A
n66
NOTE 1: Only single switched UL is supported
5.1.115.3 ∆TIB and ∆RIB values
For DC_2-29-66_n66, the TIB... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.115.4 REFSENS requirements | There is no additional REFSENS requirement for this band combination. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.116 DC_29-30-66_n66 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.116.1 Operating bands for EN-DC | Table 5.1.116.1-1: Band combinations EN-DC (three bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_29-30-66_n66
CA_29-30-66
n66 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.116.2 Configuration for DC | Table 5.1.116.2-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_29A-30A-66A_n66A
DC_30A_n66A
DC_66A_n66A1
CA_29A-30A-66A
n66
NOTE 1: Only single switched UL is supported
5.1.116.3 ∆TIB and ∆RIB values
For DC_29-30-66_n66, the ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.116.4 REFSENS requirements | There is no additional REFSENS requirement for this band combination. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.117 DC_29-30-66_n2 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.117.1 Operating bands for EN-DC | Table 5.1.117.1-1: Band combinations EN-DC (three bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_29-30-66_n2
CA_29-30-66
n2 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.117.2 Configuration for DC | Table 5.1.117.2-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_29A-30A-66A_n2A
DC_30A_n2A
DC_66A_n2A
CA_29A-30A-66A
n2
5.1.117.3 ∆TIB and ∆RIB values
For DC_29-30-66_n2, the TIB,c and RIB,c values are reused from EN-DC combi... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.117.4 REFSENS requirements | There is no additional REFSENS requirement for this band combination. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.118 DC_2-29-30_n2 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.118.1 Operating bands for EN-DC | Table 5.1.118.1-1: Band combinations EN-DC (three bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-29-30_n2
CA_2-29-30
n2 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.118.2 Configuration for DC | Table 5.1.118.2-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-29A-30A_n2A
DC_2A_n2A1
DC_30A_n2A
CA_2-29A-30A
n2
NOTE1: Only single switched UL is supported
5.1.118.3 ∆TIB and ∆RIB values
For DC_2-29-30_n2, the TIB,c and ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.118.4 REFSENS requirements | There is no additional REFSENS requirement for this band combination. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.119 DC_2-29-30_n2 |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.