hash stringlengths 32 32 | doc_id stringlengths 5 12 | section stringlengths 5 1.47k | content stringlengths 0 6.67M |
|---|---|---|---|
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.54.2 Configuration for DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-7A-8A_n78A
DC_1A_n78A
DC_7A_n78A
DC_8A_n78A
CA_1A-7A-8A
n78A
5.1.54.3 ∆TIB and ∆RIB values
For DC_1-7-8_n78 the TIB,c and RIB,c values are given in the tab... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.54.4 REFSENS requirements | REFSENS requirements are already covered in 2DL/2UL and 3DL/2UL fall-back modes. No additional REFSENS requirement is required.
5.1.55 DC_1-3-20_n38 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.55.1 Operating bands for EN-DC | Table 5.1.55.1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-20_n38
CA_1-3-20
n38
NO
5.1.55.2 Configuration for EN-DC
Table 5.1.55.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA CA configuration
NR band
DC_1A-3A... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.55.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration.
5.1.56 DC_1-7-20_n3
5.1.56.1 Operating bands for EN-DC
Table 5.1.56.1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-7-20_n3
CA_1-7-20
n3
DC_1_n3
5.1.56.2 Configuration for EN-DC... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.56.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.2 Inter-band EN-DC including FR2 | 5.1.57 DC_1-20-38_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.57.1 Operating bands for EN-DC | Table 5.1.57.1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-20-38_n78
CA_1-20-38
n78
NO
5.1.57.2 Configuration for EN-DC
Table 5.1.57.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR ba... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.57.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration.
5.1.58 DC_3-20-38_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.58.1 Operating bands for EN-DC | Table 5.1.58.1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-20-38_n78
CA_3-20-38
n78
NO
5.1.58.2 Configuration for EN-DC
Table 5.1.58.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR ba... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.58.4 REFSENS requirements | No additional MSD requirement need to be defined for this dual connectivity configuration.
5.1.59 DC_1-3-20-38_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.59.1 Operating bands for EN-DC | Table 5.1.59.1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-20-38_n78
CA_1-3-20-38
n78
NO
5.1.59.2 Configuration for EN-DC
Table 5.1.59.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
N... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.61 DC_2-12-30_n2 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.61.1 Operating bands for DC | Table 5.1.61.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-12-30_n2
CA_2-12-30
n2
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.61.2 Configuration for DC | Table 5.1.61.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-12A-30A_n2A
DC_12A_n2A
DC_30A_n2A
CA_2A-12A-30A
n2A
5.1.61.3 ∆TIB and ∆RIB values
For DC_2-12-30_n2, the TIB,c and RIB,c values are derived from CA_2-2-12-30 in TS ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.62 DC_2-12-66_n2 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.62.1 Operating bands for DC | Table 5.1.62.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-12-66_n2
CA_2-12-66
n2
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.62.2 Configuration for DC | Table 5.1.62.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-12A-66A_n2A
DC_12A_n2A
DC_66A_n2A
CA_2A-12A-66A
n2A
DC_2A-12A-66A-66A_n2A
DC_12A_n2A
DC_66A_n2A
CA_2A-12A-66A-66A
n2A
5.1.62.3 ∆TIB and ∆RIB values
For DC_2-12-66_n2,... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.63 DC_1A-3A-28A_n7A | DC_1A-3C-28A_n7A
DC_1A-3A-3A-28A_n7A
DC_1A-1A-3A-28A_n7A
DC_1A-1A-3C-28A_n7A
DC_1A-1A-3A-3A-28A_n7A
DC_1A-3A-28A_n7B
DC_1A-3C-28A_n7B
DC_1A-3A-3A-28A_n7B
DC_1A-1A-3A-28A_n7B
DC_1A-1A-3C-28A_n7B
DC_1A-1A-3A-3A-28A_n7B |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.63.1 Operating bands for DC | Table 5.1.63.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-28_n7
CA_1-3-28
n7
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.63.2 Configuration for DC | Table 5.1.63.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3A-28A_n7A
DC_1A-3C-28A_n7A
DC_1A-3A-28A_n7B
DC_1A-3C-28A_n7B
DC_1A_n7A
DC_3A_n7A
DC_3C_n7A
DC_28A_n7A
CA_1A-3A-28A
CA_1A-3C-28A
n7A
n7B
DC_1A-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.63.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.64 DC_3A-7A-28A_n7A | DC_3C-7A-28A_n7A
DC_3A-3A-7A-28A_n7A |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.64.1 Operating bands for DC | Table 5.1.64.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_3-7-28_n7
CA_3-7-28
n7
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.64.2 Configuration for DC | Table 5.1.64.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_3A-7A-28A_n7A
DC_3C-7A-28A_n7A
DC_3A_n7A
DC_3C_n7A
DC_7A_n7A1
DC_28A_n7A
CA_3A-7A-28A
CA_3C-7A-28A
n7A
DC_3A-3A-7A-28A_n7A
DC_3A_n7A
DC_7A_n7A1
DC... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.64.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.65 DC_1A-3A-7A_n7A | DC_1A-3C-7A_n7A
DC_1A-3A-3A-7A_n7A
DC_1A-1A-3A-7A_n7A
DC_1A-1A-3C-7A_n7A |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.65.1 Operating bands for DC | Table 5.1.65.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-7_n7
CA_1-3-7
n7
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.65.2 Configuration for DC | Table 5.1.65.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3A-7A_n7A
DC_1A-3C-7A_n7A
DC_1A_n7A
DC_3A_n7A
DC_7A_n7A1
CA_1A-3A-7A
CA_1A-3C-7A
n7A
DC_1A-1A-3A-7A_n7A
DC_1A-1A-3C-7A_n7A
DC_1A-3A-3A-7A_n7A
D... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.65.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.66 DC_1A-7A-28A_n7A | DC_1A-1A-7A-28A_n7A |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.66.1 Operating bands for DC | Table 5.1.66.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-7-28_n7
CA_1-7-28
n7
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.66.2 Configuration for DC | Table 5.1.66.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-7A-28A_n7A
DC_1A_n7A
DC_7A_n7A1
DC_28A_n7A
CA_1A-7A-28A
n7A
DC_1A-1A-7A-28A_n7A
DC_1A_n7A
DC_7A_n7A1
DC_28A_n7A
CA_1A-1A-7A-28A
n7A
NOTE 1: Onl... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.66.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.67 2A-12A-66A_n66A | 2A-2A-12A-66A_n66A |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.67.1 Operating bands for DC | Table 5.1.67.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-12-66_n66
CA_2-12-66
n66
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.67.2 Configuration for DC | Table 5.1.67.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-12A-66A_n66A
DC_2A_n66A
DC_12A_n66A
DC_66A_n66A1
CA_2A-12A-66A
n66A
DC_2A-2A-12A-66A_n66A
DC_2A_n66A
DC_12A_n66A
DC_66A_n66A1
CA_2A-2A-12A-66A-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.67.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.68 2A-30A-66A_n66A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.68.1 Operating bands for DC | Table 5.1.68.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-30-66_n66
CA_2-30-66
n66
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.68.2 Configuration for DC | Table 5.1.68.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-30A-66A_n66A
DC_2A_n66A
DC_30A_n66A
DC_66A_n66A1
CA_2A-30A-66A
n66A
NOTE 1: Only single switched UL is supported
5.1.68.3 ∆TIB and ∆RIB values
... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.68.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.69 12A-30A-66A_n66A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.69.1 Operating bands for DC | Table 5.1.69.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_12-30-66_n66
CA_12-30-66
n66
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.69.2 Configuration for DC | Table 5.1.69.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_12A-30A-66A_n66A
DC_12A_n66A
DC_30A_n66A
DC_66A_n66A1
CA_12A-30A-66A
n66A
NOTE 1: Only single switched UL is supported
5.1.69.3 ∆TIB and ∆RIB valu... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.69.4 REFSENS requirements | No further MSD are needed to be specified.
5.1.70 DC_2-5-48_n12 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.70.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-5-48_n12
CA_2-5-48
n12 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.70.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-5A-48A_n12A
DC_2A_n12A
DC_5A_n12A
DC_48A_n12A
CA_2A-5A-48A
n12
5.1.70.3 ∆TIB and ∆RIB values
Based on CA_2-5-12 and CA_2-48 following is proposed
Table 6.2B.4.2.3.... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.71.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-5-66_n12
CA_2-5-66
n12 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.71.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-5A-66A_n12A
DC_2A_n12A
DC_5A_n12A
DC_66A_n12A
CA_2A-5A-66A
n12
5.1.71.3 ∆TIB and ∆RIB values
Based on CA_2-5-12-66 following is proposed
Table 6.2B.4.2.3.3-1: ΔTIB... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.72.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-12-48_n5
CA_2-12-48
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.72.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-12A-48A_n5A
DC_2A_n5A
DC_12A_n5A
DC_48A_n5A
CA_2A-12A-48A
n5
5.1.72.3 ∆TIB and ∆RIB values
Based on CA_2-5-12 and CA_2-48 following values are proposed.
Table 6.2B... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.73.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-12-66_n5
CA_2-12-66
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.73.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-12A-66A_n5A
DC_2A_n5A
DC_12A_n5A
DC_66A_n5A
CA_2A-12A-66A
n5
5.1.73.3 ∆TIB and ∆RIB values
Based on CA_2-5-12-66 following values are proposed.
Table 6.2B.4.2.3.3-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.74.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_2-48-66_n5
CA_2-48-66
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.74.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_2A-48A-66A_n5A
DC_2A_n5A
DC_48A_n5A
DC_66A_n5A
CA_2A-48A-66A
n5
5.1.74.3 ∆TIB and ∆RIB values
Based on CA_2-5-66 and CA_2-48-66 following values are proposed.
Table 6... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.75.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_5-48-66_n12
CA_5-48-66
n12 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.75.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_5A-48A-66A_n12A
DC_5A_n12A
DC_48A_n12A
DC_66A_n12A
CA_5A48A-66A
n12
5.1.75.3 ∆TIB and ∆RIB values
Based on CA_5-48-66 and CA_5-12-48 following is proposed
Table 6.2B.... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.76.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_12-48-66_n5
CA_12-48-66
n5 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.76.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_12A-48A-66A_n5A
DC_12A_n5A
DC_48A_n5A
DC_66A_n5A
CA_12A-48A-66A
n5
5.1.76.3 ∆TIB and ∆RIB values
Based on CA_5-12-66 and CA_48-66 following values are proposed.
Table... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.77 DC_2-5-66_n66 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.77.1 Operating bands for DC | Table 5.1.77.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-5-66_n66
CA_2-5-66
n66
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.77.2 Configuration for DC | Table 5.1.77.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-2A-5A-66A-66A_n66A
DC_5A_n66A
CA_2A-5A-66A
n66A
DC_2A-5A-66A-66A_n66A
DC_5A_n66A
CA_2A-5A-5A-66A
n66A
DC_2A-5A-5A-66A_n66A
DC_5A_n66A
CA_2A-5A-5A-66A-66A
n66A
DC_2A-5... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.78 DC_2-13-66_n2 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.78.1 Operating bands for DC | Table 5.1.78.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-13-66_n2
CA_2-13-66
n2
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.78.2 Configuration for DC | Table 5.1.78.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-13A-66A_n2A
DC_13A_n2A
CA_2A-13A-66A
n2A
DC_2A-13A-66A-66A_n2A
DC_13A_n2A
CA_2A-13A-66A-66A
n2A
5.1.78.3 ∆TIB and ∆RIB values
For DC_2-13-66_n2, the TIB,c and RIB,c... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.79 DC_2-13-66_n5 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.79.1 Operating bands for DC | Table 5.1.79.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-13-66_n5
CA_2-13-66
n5
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.79.2 Configuration for DC | Table 5.1.79.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-13A-66A_n5A
DC_2A_n5A
DC_66A_n5A
CA_2A-13A-66A
n5A
DC_2A-2A-13A-66A_n5A
DC_2A_n5A
DC_66A_n5A
CA_2A-2A-13A-66A
n5A
DC_2A-13A-66A-66A_n5A
DC_2A_n5A
DC_66A_n5A
CA_2A-13A... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.80 DC_2-13-66_n48 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.80.1 Operating bands for DC | Table 5.1.80.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-13-66_n48
CA_2-13-66
n48
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.80.2 Configuration for DC | Table 5.1.80.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-13A-66A_n48A
DC_2A_n48A
DC_13A_n48A
DC_66A_n48A
CA_2A-13A-66A
n48A
DC_2A-13A-66A_n48B
DC_2A_n48A
DC_13A_n48A
DC_66A_n48A
CA_2A-13A-66A
n48A
DC_2A-13A-66A-66A_n48A
DC_... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.81 DC_2-13-66_n66 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.81.1 Operating bands for DC | Table 5.1.81.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-13-66_n66
CA_2-13-66
n66
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.81.2 Configuration for DC | Table 5.1.81.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-2A-13A-66A-66A_n66A
DC_13A_n66A
CA_2A-2A-13A-66A-66A
n66A
DC_2A-2A-13A-66A_n66A
DC_13A_n66A
CA_2A-2A-13A-66A
n66A
DC_2A-13A-66A-66A_n66A
DC_13A_n66A
CA_2A-13A-66A-66A... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.82 DC_2-46-48_n5 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.82.1 Operating bands for DC | Table 5.1.82.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-46-48_n5
CA_2-46-48
n5
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.82.2 Configuration for DC | Table 5.1.82.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-46E-48A_n5A
DC_2A_n5A
DC_48A_n5A
CA_2A-46E-48A
n5A
DC_2A-46D-48A_n5A
DC_2A_n5A
DC_48A_n5A
CA_2A-46D-48A
n5A
DC_2A-46C-48A_n5A
DC_2A_n5A
DC_48A_n5A
CA_2A-46C-48A
n5A
D... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.83 DC_2-46-48_n66 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.83.1 Operating bands for DC | Table 5.1.83.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-46-48_n66
CA_2-46-48
n66
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.83.2 Configuration for DC | Table 5.1.83.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
Configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-46E-48A_ n66A
DC_2A_ n66A
DC_48A_n66A
CA_2A-46E-48A
n66A
DC_2A-46D-48A_ n66A
DC_2A_ n66A
DC_48A_n66A
CA_2A-46D-48A
n66A
DC_2A-46C-48A_ n66A
DC_2A_ n66A
DC_48A_n66A
CA... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.84 DC_2A-7A-66A_n38A | DC_2A-2A-7A-66A_n38A |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.84.1 Operating bands for DC | Table 5.1.84.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-7-66_n381
CA_2-7-66
n38
NOTE 1: UL carrier shall be supported in Band 2 or band 66 only. Power imbalance between downlink carriers on Band 7 and Band 38 is assumed to be within [6dB]. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.84.2 Configuration for DC | Table 5.1.84.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-7A-66A_n38A
2A1
66A1
CA_2A-7A-66A
n38A
DC_2A-2A-7A-66A_n38A
2A1
66A1
CA_2A-2A-7A-66A
n38A
NOTE 1: UL carrier shall be supported in Band 2 or ba... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.84.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.85 DC_2A-66A-71A_n38A | DC_2A-2A-66A-71A_n38A |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.85.1 Operating bands for DC | Table 5.1.85.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-66-71_n38
CA_2-66-71
n38
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.85.2 Configuration for DC | Table 5.1.85.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-66A-71A_n38A
DC_2A_n38A
DC_66A_n38A
DC_71A_n38A
CA_2A-66A-71A
n38A
DC_2A-2A-66A-71A_n38A
DC_2A_n38A
DC_66A_n38A
DC_71A_n38A
CA_2A-2A-66A-71A
n3... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.85.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.86 DC_2A-7A-66A_n71A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.86.1 Operating bands for DC | Table 5.1.86.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-7-66_n71
CA_2-7-66
n71
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.86.2 Configuration for DC | Table 5.1.86.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-7A-66A_n71A
DC_2A_n71A
DC_7A_n71A
DC_66A_n71A
CA_2A-66A-71A
n71A
5.1.86.3 ∆TIB and ∆RIB values
For DC_2-7-66_n71 the TIB,c and RIB,c values a... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.86.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.87 DC_2A-66A-71A_n66A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.87.1 Operating bands for DC | Table 5.1.87.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-66-71_n66
CA_2-66-71
n66 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.87.2 Configuration for DC | Table 5.1.87.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-66A-71A_n66A
DC_2A_n66A
DC_66A_n66A1
DC_71A_n66A
CA_2A-66A-71A
n66A
NOTE 1: Only single switched UL is supported
5.1.87.3 ∆TIB and ∆RIB values... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.87.4 REFSENS requirements | No further MSD are needed to be specified. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.88 DC_2A-66A-71A_n78A | DC_2A-2A-66A-71A_n78A |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.88.1 Operating bands for DC | Table 5.1.88.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-66-71_n78
CA_2-66-71
n78
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.88.2 Configuration for DC | Table 5.1.88.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-66A-71A_n78A
DC_2A_n78A
DC_66A_n78A
DC_71A_n78A
CA_2A-66A-71A
n78A
DC_2A-2A-66A-71A_n78A
DC_2A_n78A
DC_66A_n78A
DC_71A_n78A
CA_2A-2A-66A-71A
n7... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.88.4 REFSENS requirements | No further MSD are needed to be specified. |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.