hash
stringlengths
32
32
doc_id
stringlengths
5
12
section
stringlengths
5
1.47k
content
stringlengths
0
6.67M
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.24.1 Operating bands for DC
Table 5.1.24.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_1-7-28_n781 CA_1-7-28 n78 No NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.24.2 Configuration for DC
Table 5.1.24.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-7A-28A_n78A DC_1A-7C-28A_n78A DC_1A_n78A DC_7A_n78A DC_7C_n78A DC_28A_n78A CA_1A-7A-28A CA_1A-7C-28A n78A 5.1.24.3 ∆TIB and ∆RIB values For DC_...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.24.4 REFSENS requirements
No further MSD are needed to be specified for DC_1A-7A-28A_n78A or DC_1A-7C-28A_n78A.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.25 DC_1A-3C-8A_n78A
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.25.1 Operating bands for DC
Table 5.2B.4.3-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA CA band NR band Single UL allowed DC_1-3-8_n78 CA_1-3-8 N78 DC_3_n78
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.25.2 Configuration for EN-DC
Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA CA configuration NR band DC_1A-3C-8A_n78A DC_1A_n78A DC_3A_n78A DC_8A_n78A CA_1A-3C-8A n78 5.1.25.3 ∆TIB and ∆RIB values Table 6.2B.4.2.3.3-1: ΔTIB,c Inter-band DC Configuration E-UTRA and NR Ba...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.26 DC_3C-7A-28A_n78A_BCS0
DC_3C-7C-28A_n78A_BCS0
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.26.1 Operating bands for DC
Table 5.1.26.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_3-7-28_n781 CA_3-7-28 n78 DC_3_n78 NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.26.2 Configuration for DC
Table 5.1.26.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_3C-7A-28A_n78A DC_3A_n78A DC_7A_n78A DC_28A_n78A CA_3C-7A-28A n78A DC_3C-7C-28A_n78A DC_3A_n78A DC_7A_n78A DC_28A_n78A CA_3C-7C-28A n78A 5.1.26.3 ...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.26.4 REFSENS requirements
No further MSD are needed to be specified for DC_3C-7A-28A_n78A, DC_3C-7C-28A_n78A.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.27 DC_1-3-8_n77
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.27.1 Operating bands for EN-DC
Table 5.1.27.1-1: Band combinations EN-DC (four bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_1-3-8_n77 CA_1-3-8 n77 DC_1_n77 DC_3_n77
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.27.2 Configurations for EN-DC
Table 5.1.27.2-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-3A-8A_n77A DC_1A_n77A DC_3A_n77A DC_8A_n77A CA_1A-3A-8A n77A 5.1.27.3 ∆TIB and ∆RIB values For DC_1A-3A-8A_n77A, the TIB,c and RIB,c values are given in th...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.27.4 REFSENS requirements
Co-existence study for DC_1-3-8_n77 was covered by the studies for the fallback modes of DC_1-3_n77, DC_1-8_n77 and DC_3-8_n77. No additional MSD requirement need to be defined for this dual connectivity configuration.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.28 DC_1-3-8_n79
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.28.1 Operating bands for EN-DC
Table 5.1.28.1-1: Band combinations EN-DC (four bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_1-3-8_n79 CA_1-3-8 n79
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.28.2 Configurations for EN-DC
Table 5.1.28.2-1: Inter-band EN-DC configurations (four bands) EN-DC Configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-3A-8A_n79A DC_1A_n79A DC_3A_n79A DC_8A_n79A CA_1A-3A-8A n79A 5.1.28.3 ∆TIB and ∆RIB values For DC_1A-3A-8A_n79A, the TIB,c and RIB,c values are given in th...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.28.4 REFSENS requirements
Co-existence study for DC_1-3-8_n79 was covered by the studies for the fallback modes of DC_1-3_n79, DC_1-8_n79 and DC_3-8_n79. No additional MSD requirement need to be defined for this dual connectivity configuration.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.29 DC_2A-30A-66A_n5A, DC_2A-2A-30A-66A_n5A and DC_2A-30A-66A-66A_n5A
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.29.1 Operating bands for DC
Table 5.1.29.1-1: Band combinations EN-DC (four bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_2-30-66_n5 CA_2-30-66 n5 No
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.29.2 Configuration for DC
Table 5.1.29.2-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration E-UTRA configuration NR configuration DC_2A-30A-66A_n5A DC_2A_n5A DC_30A_n5A DC_66A_n5A CA_2A-30A-66A n5A DC_2A-2A-30A-66A_n5A DC_2A_n5A DC_30A_n5A DC_66A_n5A CA_2A-2A-30A-66A n5A DC_2A-30A-66A-66A_n5A DC_2A_n5...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.29.3 Coexistence studies
Based on co-existence studies of DC_66A_n5A in TR 37.863-01-01, the 2nd and 5th IMD of 66+n5 may fall into the band n5 downlink and Pcell REFSENS excpetions can be represented by the REFSENS expcetion already specified for DC_66A-n5A. Based on co-existence studies of DC_30A_n5A in TR 37.863-01-01, 5th IMD product of 30...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.29.5 Refsens requirements
No further refsens requirements are needed as this is covered by lower order combinations.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.30 DC_1A-3A-7A_n5A_BCS0
DC_1A-3C-7A_n5A_BCS0 DC_1A-3A-7C_n5A_BCS0 DC_1A-3C-7C_n5A_BCS0
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.30.1 Operating bands for DC
Table 5.1.30.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_1-3-7_n51 CA_1-3-7 n5 DC_3_n5 DC_7_n5 NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.30.2 Configuration for DC
Table 5.1.30.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-3A-7A_n5A DC_1A_n5A DC_3A_n5A DC_7A_n5A CA_1A-3A-7A n5A DC_1A-3C-7A_n5A DC_1A_n5A DC_3A_n5A DC_3C_n5A DC_7A_n5A CA_1A-3C-7A n5A DC_1A-3A-7C_n5A...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.30.4 REFSENS requirements
No further MSD are needed to be specified for DC_1A-3A-7A_n5A, DC_1A-3C-7A_n5A, DC_1A-3A-7C_n5A and DC_1A-3C-7C_n5A.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.31 DC_1A-3A-28A_n5A_BCS0
DC_1A-3C-28A_n5A_BCS0
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.31.1 Operating bands for DC
Table 5.1.31.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_1-3-28_n51 CA_1-3-28 n5 DC_3_n5 NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.31.2 Configuration for DC
Table 5.1.31.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-3A-28A_n5A DC_1A_n5A DC_3A_n5A DC_28A_n5A CA_1A-3A-28A n5A DC_1A-3C-28A_n5A DC_1A_n5A DC_3A_n5A DC_3C_n5A DC_28A_n5A CA_1A-3C-28A n5A 5.1.31.3 ...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.31.4 REFSENS requirements
No further MSD are needed to be specified for DC_1A-3A-28A_n5A and DC_1A-3C-28A_n5A.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.32 DC_1A-7A-28A_n5A_BCS0
DC_1A-7C-28A_n5A_BCS0
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.32.1 Operating bands for DC
Table 5.1.32.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_1-7-28_n51 CA_1-7-28 n5 DC_7_n5 NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.32.2 Configuration for DC
Table 5.1.32.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-7A-28A_n5A DC_1A_n5A DC_7A_n5A DC_28A_n5A CA_1A-7A-28A n5A DC_1A-7C-28A_n5A DC_1A_n5A DC_7A_n5A DC_7C_n5A DC_28A_n5A CA_1A-7C-28A n5A 5.1.32.3 ...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.32.4 REFSENS requirements
No further MSD are needed to be specified for DC_1A-7A-28A_n5A and DC_1A-7C-28A_n5A.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.33 DC_3A-7A-28A_n5A_BCS0
DC_3C-7A-28A_n5A_BCS0 DC_3A-7C-28A_n5A_BCS0 DC_3C-7C-28A_n5A_BCS0
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.33.1 Operating bands for DC
Table 5.1.33.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_3-7-28_n51 CA_3-7-28 n5 DC_3_n5 DC_7_n5 NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.33.2 Configuration for DC
Table 5.1.33.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_3A-7A-28A_n5A DC_3A_n5A DC_7A_n5A DC_28A_n5A CA_3A-7A-28A n5A DC_3C-7A-28A_n5A DC_3A_n5A DC_3C_n5A DC_7A_n5A DC_28A_n5A CA_3C-7A-28A n5A DC_3A-7C-...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.33.4 REFSENS requirements
No further MSD are needed to be specified for DC_3A-7A-28A_n5A, DC_3C-7A-28A_n5A, DC_3A-7C-28A_n5A and DC_3C-7C-28A_n5A.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.34 DC_1-8-11_n77
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.34.1 Operating bands for EN-DC
Table 5.1.34.1-1: Band combinations EN-DC (four bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_1-8-11_n77 CA_1-8-11 n77 DC_1_n77
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.34.2 Configurations for EN-DC
Table 5.1.34.2-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-8A-11A_n77A DC_1A_n77A DC_8A_n77A DC_11A_n77A CA_1A-8A-11A n77A 5.1.34.3 ∆TIB and ∆RIB values For DC_1A-8A-11A_n77A, the TIB,c and RIB,c values are given i...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.34.4 REFSENS requirements
Co-existence study for DC_1-8-11_n77 was covered by the studies for the fallback modes of DC_1-8_n77, DC_1-11_n77 and DC_8-11_n77. No additional MSD requirement need to be defined for this dual connectivity configuration.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.35 DC_1-8-11_n78
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.35.1 Operating bands for EN-DC
Table 5.1.35.1-1: Band combinations EN-DC (four bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_1-8-11_n78 CA_1-8-11 n78 DC_1_n78
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.35.2 Configurations for EN-DC
Table 5.1.35.2-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-8A-11A_n78A DC_1A_n78A DC_8A_n78A DC_11A_n78A CA_1A-8A-11A n78A 5.1.35.3 ∆TIB and ∆RIB values For DC_1A-8A-11A_n77A, the TIB,c and RIB,c values are given i...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.35.4 REFSENS requirements
Co-existence study for DC_1-8-11_n78 was covered by the studies for the fallback modes of DC_1-8_n78, DC_1-11_n78 and DC_8-11_n78. No additional MSD requirement need to be defined for this dual connectivity configuration.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.36 DC_3-7-8_n78, DC_3-3-7-8_n78, DC_3-7-7-8_n78, DC_3-3-7-7-8_n78
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.36.1 Operating bands for DC
Table 5.1.36.1-1: Band combinations EN-DC (three bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_3-7-8_n78 CA_3-7-8 n78 DC_3_n78 DC_3-3-7-8_n78 CA_3-3-7-8 n78 DC_3_n78 DC_3-7-7-8_n78 CA_3-7-7-8 n78 DC_3_n78 DC_3-3-7-7-8_n78 CA_3-3-7-7-8 n78 DC_3_n78
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.36.2 Configuration for DC
Table 5.1.36.2-1: Inter-band EN-DC configurations (three bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_3A-7A-8A_n78A DC_3A_n78A, DC_7A_n78A, DC_8A_n78A CA_3A-7A-8A n78A DC_3A-3A-7A-8A_n78A DC_3A_n78A, DC_7A_n78A, DC_8A_n78A CA_3A-3A-7A-8A n78A DC_3A-7A-7A-8A_n7...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.36.3 Co-existence Studies
Based on co-existence studies of DC_3_n78, DC_7_n78 and DC_8_n78, as captured in TR 37.716-11-11 and TR 37.863-01-01, own Rx impact on the 3rd band are the following: - 2nd and 5th order IM generated by dual uplink of Band 7 and n78 may fall into Band 8 - 3rd and 4th order IM generated by dual uplink of Band 7 and n78 ...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.36.5 REFSENS requirements
No additional MSD requirement is needed.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.37 DC_2-7-66_n66, DC_2-7-7-66_n66
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.37.1 Operating bands for DC
Table 5.1.37.1-1: Band combinations EN-DC (four bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_2-7-66_n66 CA_2-7-66 n66 DC_2-7-7-66_n66 CA_2-7-7-66 n66
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.37.2 Configurations for DC
Table 5.1.37.2-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_2A-7A-66A_n66A DC_2A-7C-66A_n66A DC_2A-7A-7A-66A_n66A DC_2A_n66A1 DC_7A_n66A DC_66A_n66A2 CA_2A-7A-66A CA_2A-7C-66A CA_2A-7A-7A-66A n66A NOTE1: Single UL is all...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.37.3 Coexistence study
Co-existence studies of this 4DL/2UL DC configuration are already covered in the constituent fall-back modes. Therefore, no additional studies are needed. 5.1.37.4 ∆TIB and ∆RIB values DC_2-7-66_n66 and DC_2-7-7-66_n66 could reuse the TIB,c and RIB,c values of CA_2A-7A-66A-66A as given in below tables. Table 5.1.37....
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.37.5 REFSENS requirements
There is no additional requirement for this band combination. 5.1.38 DC_2-7-66_n78
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.38.1 Configuration for EN-DC
Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) DC_2A-7A-66A_n78A DC_2A-7A-7A-66A_n78A DC_2A-7C-66A_n78A DC_2A-7A-66A-66A_n78A DC_2A-7A-7A-66A-66A_n78A DC_2A-7C-66A-66A_n78A DC_2A-7A-66A_n78(2A) DC_2A-7A-7A-66A_n78(2A) DC_2A-7C-66A_n78(2A) DC_2A-7A-...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.40 DC_2A-12A-30A_n66A_BCS0
DC_2A-2A-12A-30A_n66A_BCS0
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.40.1 Operating bands for DC
Table 5.1.40.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_2-12-30_n66 CA_2-12-30 n66 DC_2_n66
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.40.2 Configuration for DC
Table 5.1.40.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_2A-12A-30A_n66A DC_2A_n66A DC_12A_n66A DC_30A_n66A CA_2A-12A-30A n66A DC_2A-2A-12A-30A_n66A DC_2A_n66A DC_12A_n66A DC_30A_n66A CA_2A-2A-12A-30A n6...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.40.4 REFSENS requirements
No further MSD are needed to be specified for DC_2A-12A-30A_n66A and DC_2A-2A-12A-30A_n66A.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.41 DC_12A-30A-66A_n2A_BCS0
DC_12A-30A-66A-66A_n2A_BCS0
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.41.1 Operating bands for DC
Table 5.1.41.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_12-30-66_n2 CA_12-30-66 n2 DC_66_n2
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.41.2 Configuration for DC
Table 5.1.41.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_12A-30A-66A_n2A DC_12A_n2A DC_30A_n2A DC_66A_n2A CA_12A-30A-66A n2A DC_12A-30A-66A-66A_n2A DC_12A_n2A DC_30A_n2A DC_66A_n2A CA_12A-30A-66A-66A n2A...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.41.4 REFSENS requirements
No further MSD are needed to be specified for DC_12A-30A-66A_n2A and DC_12A-30A66A-66A_n2A.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.42 2A-14A-30A_n260M
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.42.1 Operating bands for DC
Table 5.1.42.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_2-14-30_n260 CA_2-14-30 n260 No
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.42.2 Configuration for DC
Table 5.1.42.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_2A-14A-30A_n260A DC_2A-14A-30A_n260G DC_2A-14A-30A_n260H DC_2A-14A-30A_n260I DC_2A-14A-30A_n260J DC_2A-14A-30A_n260K DC_2A-14A-30A_n260L DC_2A-14A...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.43 2A-14A-66A_n260M
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.43.1 Operating bands for DC
Table 5.1.43.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_2-14-66_n260 CA_2-14-66 n260 No DC_2-2-14-66_n260 CA_2-14-66 n260 No DC_2-14-66-66_n260 CA_2-14-66 n260 No
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.43.2 Configuration for DC
Table 5.1.43.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_2A-14A-66A_n260A DC_2A-14A-66A_n260G DC_2A-14A-66A_n260H DC_2A-14A-66A_n260I DC_2A-14A-66A_n260J DC_2A-14A-66A_n260K DC_2A-14A-66A_n260L DC_2A-14A...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.44 14A-30A-66A_n260M
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.44.1 Operating bands for DC
Table 5.1.44.1-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_14-30-66_n260 CA_14-30-66 n260 No DC_14-30-66-66_n260 CA_14-30-66 n260 No
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.44.2 Configuration for DC
Table 5.1.44.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_14A-30A-66A_n260A DC_14A-30A-66A_n260G DC_14A-30A-66A_n260H DC_14A-30A-66A_n260I DC_14A-30A-66A_n260J DC_14A-30A-66A_n260K DC_14A-30A-66A_n260L DC...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.46 DC_1-8-42_n77
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.46.1 Operating bands for EN-DC
Table 5.1.46.1-1: Band combinations EN-DC (four bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_1-8-42_n77 CA_1-8-42 n77 DC_1_n77
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.46.2 Configurations for EN-DC
Table 5.1.46.2-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_1A-8A-42A_n77A DC_1A_n77A DC_8A_n77A CA_1A-8A-42A n77A DC_1A-8A-42C_n77A DC_1A_n77A DC_8A_n77A CA_1A-8A-42C n77A 5.1.46.3 ∆TIB and ∆RIB values For DC_1-8-42_n77...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.46.4 REFSENS requirements
Co-existence study for DC_1-8-42_n77 was covered by the studies for the fallback modes of DC_1-8_n77, DC_1-42_n77 and DC_8-42_n77. No additional MSD requirement need to be defined for this dual connectivity configuration.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.47 DC_3-8-42_n77
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.47.1 Operating bands for EN-DC
Table 5.1.47.1-1: Band combinations EN-DC (four bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_3-8-42_n77 CA_3-8-42 n77 DC_3_n77
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.47.2 Configurations for EN-DC
Table 5.1.47.2-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_3A-8A-42A_n77A DC_3A_n77A DC_8A_n77A CA_3A-8A-42A n77A DC_3A-8A-42C_n77A DC_3A_n77A DC_8A_n77A CA_3A-8A-42C n77A 5.1.47.3 ∆TIB and ∆RIB values For DC_3-8-42_n77...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.47.4 REFSENS requirements
Co-existence study for DC_3-8-42_n77 was covered by the studies for the fallback modes of DC_3-8_n77, DC_3-42_n77 and DC_8-42_n77. No additional MSD requirement need to be defined for this dual connectivity configuration.
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.48 DC_3-7-8_n1, DC_3-3-7-8_n1, DC_3-7-7-8_n1, DC_3-3-7-7-8_n1
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.48.1 Operating bands for DC
Table 5.1.48.1-1: Band combinations EN-DC (three bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_3-7-8_n1 CA_3-7-8 n1 DC_3_n1 DC_3-3-7-8_n1 CA_3-3-7-8 n1 DC_3_n1 DC_3-7-7-8_n1 CA_3-7-7-8 n1 DC_3_n1 DC_3-3-7-7-8_n1 CA_3-3-7-7-8 n1 DC_3_n1
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.48.2 Configuration for DC
Table 5.1.48.2-1: Inter-band EN-DC configurations (three bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA configuration NR configuration DC_3A-7A-8A_n1A DC_3A_n1A, DC_7A_n1A, DC_8A_n1A CA_3A-7A-8A n1A DC_3C-7A-8A_n1A DC_3C_n1A, DC_7A_n1A, DC_8A_n1A CA_3C-7A-8A n1A DC_3A-3A-7A-8A_n1A DC_3A_n1A, DC_...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.48.3 Co-existence Studies
Based on co-existence studies of DC_3-7_n1, DC_3-8_n1 and DC_7-8_n1, as captured in TR 37.716-21-11, own Rx impacts on the 3rd band are the following: - 5th order IMD generated by dual uplink of Band 7 + Band n1 may fall into own Rx of band 8. However, based on the studies for DL CA_1A-7A-8A paired with CA_1A-7A in TR ...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.48.5 REFSENS requirements
No additional MSD requirement is needed. 5.1.49 DC_3-7-40_n1 5.1.49.1 Operating bands for EN-DC Table 5.2B.4.3-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA CA band NR band Single UL allowed DC_3-7-40_n1 CA_3-7-40 n1 5.1.49.2 Configuration for EN-DC Table 5.5B.4.3-1: Inter-band EN-DC configurations (four...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.50 DC_2-46-66_n41
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.50.1 Operating bands for DC
Table 5.1.50.1-1: Band combinations EN-DC (three bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_2-46-66_n41 CA_2-46-66 n41 No
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.50.2 Configuration for DC
Table 5.1.50.2-1: Inter-band EN-DC configurations (three bands) EN-DC configuration Uplink EN-DC configuration DC_2A-46A-66A_n41A DC_2A-46C-66A_n41A DC_2A-46D-66A_n41A DC_2A_n41A DC_66A_n41A 5.1.50.3 ∆TIB and ∆RIB values The TIB,c and RIB,c values are derived from lower order combinations. Table 5.1.50.3-1: ΔTIB,c E-...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.51 DC_2-46-66_n71
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.51.1 Operating bands for DC
Table 5.1.51.1-1: Band combinations EN-DC (three bands) EN-DC Band E-UTRA Band NR Band Single UL allowed DC_2-46-66_n71 CA_2-46-66 n71 No
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.51.2 Configuration for DC
Table 5.1.51.2-1: Inter-band EN-DC configurations (three bands) EN-DC configuration Uplink EN-DC configuration DC_2A-46A-66A_n71A DC_2A-46C-66A_n71A DC_2A-46D-66A_n71A DC_2A_n71A DC_66A_n71A 5.1.51.3 ∆TIB and ∆RIB values The TIB,c and RIB,c values are derived from lower order combinations. Table 5.1.51.4-1: ΔTIB,c E-...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.52.1 Operating bands for EN-DC
Table 5.2B.4.3-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA CA band NR band Single UL allowed DC_3-28-41_n78 CA_3-28-41 n78 DC_3_n78
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.52.2 Configuration for EN-DC
Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands) EN-DC Configuration Uplink EN-DC configuration (NOTE 1) E-UTRA CA configuration NR band DC_3A-28A-41A_n78A DC_3A-28A-41C_n78A DC_3A_n78A DC_28A_n78A DC_41A_n78A DC_41C_n78A CA_ 3A-28A-41A CA_ 3A-28A-41C n78A 5.1.52.3 ∆TIB and ∆RIB values Table 6.2B.4.2.3.3-...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.53.1 Operating bands for EN-DC
Table 5.2B.4.3-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA CA band NR band Single UL allowed DC_28-41-42_n78 CA_28-41-42 n78 no
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.53.2 Configuration for EN-DC
Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands) EN-DC configuration Uplink EN-DC configuration (NOTE 1) E-UTRA CA configuration NR band DC_28A-41A-42A_n78A DC_28A-41C-42A_n78A DC_28A-41A-42C_n78A DC_28A-41C-42C_n78A DC_28A_n78A DC_41A_n78A DC_41C_n78A DC_42A_n78A DC_42C_n78A CA_ 28A-41A-42A CA_ 28A-41C-4...
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.54 1-7-8_n78
6f4cd24d580b0cdd9e7f0209ec2f2aeb
37.716-31-11
5.1.54.1 Operating bands for DC
Table 5.2B.4.3-1: Band combinations EN-DC (four bands) EN-DC band E-UTRA Band NR Band Single UL allowed DC_1-7-8_n781 CA_1-7-8 n78 No NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability