hash stringlengths 32 32 | doc_id stringlengths 5 12 | section stringlengths 5 1.47k | content stringlengths 0 6.67M |
|---|---|---|---|
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.24.1 Operating bands for DC | Table 5.1.24.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-7-28_n781
CA_1-7-28
n78
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.24.2 Configuration for DC | Table 5.1.24.2-1: Inter-band EN-DC configurations of 1 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-7A-28A_n78A
DC_1A-7C-28A_n78A
DC_1A_n78A
DC_7A_n78A
DC_7C_n78A
DC_28A_n78A
CA_1A-7A-28A
CA_1A-7C-28A
n78A
5.1.24.3 ∆TIB and ∆RIB values
For DC_... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.24.4 REFSENS requirements | No further MSD are needed to be specified for DC_1A-7A-28A_n78A or DC_1A-7C-28A_n78A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.25 DC_1A-3C-8A_n78A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.25.1 Operating bands for DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_1-3-8_n78
CA_1-3-8
N78
DC_3_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.25.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_1A-3C-8A_n78A
DC_1A_n78A
DC_3A_n78A
DC_8A_n78A
CA_1A-3C-8A
n78
5.1.25.3 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.3-1: ΔTIB,c
Inter-band DC Configuration
E-UTRA and NR Ba... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.26 DC_3C-7A-28A_n78A_BCS0 | DC_3C-7C-28A_n78A_BCS0 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.26.1 Operating bands for DC | Table 5.1.26.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_3-7-28_n781
CA_3-7-28
n78
DC_3_n78
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.26.2 Configuration for DC | Table 5.1.26.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_3C-7A-28A_n78A
DC_3A_n78A
DC_7A_n78A
DC_28A_n78A
CA_3C-7A-28A
n78A
DC_3C-7C-28A_n78A
DC_3A_n78A
DC_7A_n78A
DC_28A_n78A
CA_3C-7C-28A
n78A
5.1.26.3 ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.26.4 REFSENS requirements | No further MSD are needed to be specified for DC_3C-7A-28A_n78A, DC_3C-7C-28A_n78A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.27 DC_1-3-8_n77 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.27.1 Operating bands for EN-DC | Table 5.1.27.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-8_n77
CA_1-3-8
n77
DC_1_n77
DC_3_n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.27.2 Configurations for EN-DC | Table 5.1.27.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3A-8A_n77A
DC_1A_n77A
DC_3A_n77A
DC_8A_n77A
CA_1A-3A-8A
n77A
5.1.27.3 ∆TIB and ∆RIB values
For DC_1A-3A-8A_n77A, the TIB,c and RIB,c values are given in th... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.27.4 REFSENS requirements | Co-existence study for DC_1-3-8_n77 was covered by the studies for the fallback modes of DC_1-3_n77, DC_1-8_n77 and DC_3-8_n77.
No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.28 DC_1-3-8_n79 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.28.1 Operating bands for EN-DC | Table 5.1.28.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-8_n79
CA_1-3-8
n79 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.28.2 Configurations for EN-DC | Table 5.1.28.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
Configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3A-8A_n79A
DC_1A_n79A
DC_3A_n79A
DC_8A_n79A
CA_1A-3A-8A
n79A
5.1.28.3 ∆TIB and ∆RIB values
For DC_1A-3A-8A_n79A, the TIB,c and RIB,c values are given in th... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.28.4 REFSENS requirements | Co-existence study for DC_1-3-8_n79 was covered by the studies for the fallback modes of DC_1-3_n79, DC_1-8_n79 and DC_3-8_n79.
No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.29 DC_2A-30A-66A_n5A, DC_2A-2A-30A-66A_n5A and DC_2A-30A-66A-66A_n5A | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.29.1 Operating bands for DC | Table 5.1.29.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-30-66_n5
CA_2-30-66
n5
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.29.2 Configuration for DC | Table 5.1.29.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
E-UTRA configuration
NR configuration
DC_2A-30A-66A_n5A
DC_2A_n5A
DC_30A_n5A
DC_66A_n5A
CA_2A-30A-66A
n5A
DC_2A-2A-30A-66A_n5A
DC_2A_n5A
DC_30A_n5A
DC_66A_n5A
CA_2A-2A-30A-66A
n5A
DC_2A-30A-66A-66A_n5A
DC_2A_n5... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.29.3 Coexistence studies | Based on co-existence studies of DC_66A_n5A in TR 37.863-01-01, the 2nd and 5th IMD of 66+n5 may fall into the band n5 downlink and Pcell REFSENS excpetions can be represented by the REFSENS expcetion already specified for DC_66A-n5A.
Based on co-existence studies of DC_30A_n5A in TR 37.863-01-01, 5th IMD product of 30... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.29.5 Refsens requirements | No further refsens requirements are needed as this is covered by lower order combinations. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.30 DC_1A-3A-7A_n5A_BCS0 | DC_1A-3C-7A_n5A_BCS0
DC_1A-3A-7C_n5A_BCS0
DC_1A-3C-7C_n5A_BCS0 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.30.1 Operating bands for DC | Table 5.1.30.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-7_n51
CA_1-3-7
n5
DC_3_n5
DC_7_n5
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.30.2 Configuration for DC | Table 5.1.30.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3A-7A_n5A
DC_1A_n5A
DC_3A_n5A
DC_7A_n5A
CA_1A-3A-7A
n5A
DC_1A-3C-7A_n5A
DC_1A_n5A
DC_3A_n5A
DC_3C_n5A
DC_7A_n5A
CA_1A-3C-7A
n5A
DC_1A-3A-7C_n5A... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.30.4 REFSENS requirements | No further MSD are needed to be specified for DC_1A-3A-7A_n5A, DC_1A-3C-7A_n5A, DC_1A-3A-7C_n5A and DC_1A-3C-7C_n5A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.31 DC_1A-3A-28A_n5A_BCS0 | DC_1A-3C-28A_n5A_BCS0 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.31.1 Operating bands for DC | Table 5.1.31.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-3-28_n51
CA_1-3-28
n5
DC_3_n5
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.31.2 Configuration for DC | Table 5.1.31.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-3A-28A_n5A
DC_1A_n5A
DC_3A_n5A
DC_28A_n5A
CA_1A-3A-28A
n5A
DC_1A-3C-28A_n5A
DC_1A_n5A
DC_3A_n5A
DC_3C_n5A
DC_28A_n5A
CA_1A-3C-28A
n5A
5.1.31.3 ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.31.4 REFSENS requirements | No further MSD are needed to be specified for DC_1A-3A-28A_n5A and DC_1A-3C-28A_n5A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.32 DC_1A-7A-28A_n5A_BCS0 | DC_1A-7C-28A_n5A_BCS0 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.32.1 Operating bands for DC | Table 5.1.32.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-7-28_n51
CA_1-7-28
n5
DC_7_n5
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.32.2 Configuration for DC | Table 5.1.32.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-7A-28A_n5A
DC_1A_n5A
DC_7A_n5A
DC_28A_n5A
CA_1A-7A-28A
n5A
DC_1A-7C-28A_n5A
DC_1A_n5A
DC_7A_n5A
DC_7C_n5A
DC_28A_n5A
CA_1A-7C-28A
n5A
5.1.32.3 ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.32.4 REFSENS requirements | No further MSD are needed to be specified for DC_1A-7A-28A_n5A and DC_1A-7C-28A_n5A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.33 DC_3A-7A-28A_n5A_BCS0 | DC_3C-7A-28A_n5A_BCS0
DC_3A-7C-28A_n5A_BCS0
DC_3C-7C-28A_n5A_BCS0 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.33.1 Operating bands for DC | Table 5.1.33.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_3-7-28_n51
CA_3-7-28
n5
DC_3_n5
DC_7_n5
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.33.2 Configuration for DC | Table 5.1.33.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_3A-7A-28A_n5A
DC_3A_n5A
DC_7A_n5A
DC_28A_n5A
CA_3A-7A-28A
n5A
DC_3C-7A-28A_n5A
DC_3A_n5A
DC_3C_n5A
DC_7A_n5A
DC_28A_n5A
CA_3C-7A-28A
n5A
DC_3A-7C-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.33.4 REFSENS requirements | No further MSD are needed to be specified for DC_3A-7A-28A_n5A, DC_3C-7A-28A_n5A, DC_3A-7C-28A_n5A and DC_3C-7C-28A_n5A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.34 DC_1-8-11_n77 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.34.1 Operating bands for EN-DC | Table 5.1.34.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-8-11_n77
CA_1-8-11
n77
DC_1_n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.34.2 Configurations for EN-DC | Table 5.1.34.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-8A-11A_n77A
DC_1A_n77A
DC_8A_n77A
DC_11A_n77A
CA_1A-8A-11A
n77A
5.1.34.3 ∆TIB and ∆RIB values
For DC_1A-8A-11A_n77A, the TIB,c and RIB,c values are given i... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.34.4 REFSENS requirements | Co-existence study for DC_1-8-11_n77 was covered by the studies for the fallback modes of DC_1-8_n77, DC_1-11_n77 and DC_8-11_n77.
No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.35 DC_1-8-11_n78 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.35.1 Operating bands for EN-DC | Table 5.1.35.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-8-11_n78
CA_1-8-11
n78
DC_1_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.35.2 Configurations for EN-DC | Table 5.1.35.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-8A-11A_n78A
DC_1A_n78A
DC_8A_n78A
DC_11A_n78A
CA_1A-8A-11A
n78A
5.1.35.3 ∆TIB and ∆RIB values
For DC_1A-8A-11A_n77A, the TIB,c and RIB,c values are given i... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.35.4 REFSENS requirements | Co-existence study for DC_1-8-11_n78 was covered by the studies for the fallback modes of DC_1-8_n78, DC_1-11_n78 and DC_8-11_n78.
No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.36 DC_3-7-8_n78, DC_3-3-7-8_n78, DC_3-7-7-8_n78, DC_3-3-7-7-8_n78 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.36.1 Operating bands for DC | Table 5.1.36.1-1: Band combinations EN-DC (three bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_3-7-8_n78
CA_3-7-8
n78
DC_3_n78
DC_3-3-7-8_n78
CA_3-3-7-8
n78
DC_3_n78
DC_3-7-7-8_n78
CA_3-7-7-8
n78
DC_3_n78
DC_3-3-7-7-8_n78
CA_3-3-7-7-8
n78
DC_3_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.36.2 Configuration for DC | Table 5.1.36.2-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_3A-7A-8A_n78A
DC_3A_n78A,
DC_7A_n78A,
DC_8A_n78A
CA_3A-7A-8A
n78A
DC_3A-3A-7A-8A_n78A
DC_3A_n78A,
DC_7A_n78A,
DC_8A_n78A
CA_3A-3A-7A-8A
n78A
DC_3A-7A-7A-8A_n7... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.36.3 Co-existence Studies | Based on co-existence studies of DC_3_n78, DC_7_n78 and DC_8_n78, as captured in TR 37.716-11-11 and TR 37.863-01-01, own Rx impact on the 3rd band are the following:
- 2nd and 5th order IM generated by dual uplink of Band 7 and n78 may fall into Band 8
- 3rd and 4th order IM generated by dual uplink of Band 7 and n78 ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.36.5 REFSENS requirements | No additional MSD requirement is needed. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.37 DC_2-7-66_n66, DC_2-7-7-66_n66 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.37.1 Operating bands for DC | Table 5.1.37.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-7-66_n66
CA_2-7-66
n66
DC_2-7-7-66_n66
CA_2-7-7-66
n66 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.37.2 Configurations for DC | Table 5.1.37.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-7A-66A_n66A
DC_2A-7C-66A_n66A
DC_2A-7A-7A-66A_n66A
DC_2A_n66A1
DC_7A_n66A
DC_66A_n66A2
CA_2A-7A-66A
CA_2A-7C-66A
CA_2A-7A-7A-66A
n66A
NOTE1: Single UL is all... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.37.3 Coexistence study | Co-existence studies of this 4DL/2UL DC configuration are already covered in the constituent fall-back modes. Therefore, no additional studies are needed.
5.1.37.4 ∆TIB and ∆RIB values
DC_2-7-66_n66 and DC_2-7-7-66_n66 could reuse the TIB,c and RIB,c values of CA_2A-7A-66A-66A as given in below tables.
Table 5.1.37.... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.37.5 REFSENS requirements | There is no additional requirement for this band combination.
5.1.38 DC_2-7-66_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.38.1 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
DC_2A-7A-66A_n78A
DC_2A-7A-7A-66A_n78A
DC_2A-7C-66A_n78A
DC_2A-7A-66A-66A_n78A
DC_2A-7A-7A-66A-66A_n78A
DC_2A-7C-66A-66A_n78A
DC_2A-7A-66A_n78(2A)
DC_2A-7A-7A-66A_n78(2A)
DC_2A-7C-66A_n78(2A)
DC_2A-7A-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.40 DC_2A-12A-30A_n66A_BCS0 | DC_2A-2A-12A-30A_n66A_BCS0 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.40.1 Operating bands for DC | Table 5.1.40.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-12-30_n66
CA_2-12-30
n66
DC_2_n66 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.40.2 Configuration for DC | Table 5.1.40.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-12A-30A_n66A
DC_2A_n66A
DC_12A_n66A
DC_30A_n66A
CA_2A-12A-30A
n66A
DC_2A-2A-12A-30A_n66A
DC_2A_n66A
DC_12A_n66A
DC_30A_n66A
CA_2A-2A-12A-30A
n6... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.40.4 REFSENS requirements | No further MSD are needed to be specified for DC_2A-12A-30A_n66A and DC_2A-2A-12A-30A_n66A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.41 DC_12A-30A-66A_n2A_BCS0 | DC_12A-30A-66A-66A_n2A_BCS0 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.41.1 Operating bands for DC | Table 5.1.41.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_12-30-66_n2
CA_12-30-66
n2
DC_66_n2 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.41.2 Configuration for DC | Table 5.1.41.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_12A-30A-66A_n2A
DC_12A_n2A
DC_30A_n2A
DC_66A_n2A
CA_12A-30A-66A
n2A
DC_12A-30A-66A-66A_n2A
DC_12A_n2A
DC_30A_n2A
DC_66A_n2A
CA_12A-30A-66A-66A
n2A... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.41.4 REFSENS requirements | No further MSD are needed to be specified for DC_12A-30A-66A_n2A and DC_12A-30A66A-66A_n2A. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.42 2A-14A-30A_n260M | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.42.1 Operating bands for DC | Table 5.1.42.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-14-30_n260
CA_2-14-30
n260
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.42.2 Configuration for DC | Table 5.1.42.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-14A-30A_n260A
DC_2A-14A-30A_n260G
DC_2A-14A-30A_n260H
DC_2A-14A-30A_n260I
DC_2A-14A-30A_n260J
DC_2A-14A-30A_n260K
DC_2A-14A-30A_n260L
DC_2A-14A... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.43 2A-14A-66A_n260M | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.43.1 Operating bands for DC | Table 5.1.43.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_2-14-66_n260
CA_2-14-66
n260
No
DC_2-2-14-66_n260
CA_2-14-66
n260
No
DC_2-14-66-66_n260
CA_2-14-66
n260
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.43.2 Configuration for DC | Table 5.1.43.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_2A-14A-66A_n260A
DC_2A-14A-66A_n260G
DC_2A-14A-66A_n260H
DC_2A-14A-66A_n260I
DC_2A-14A-66A_n260J
DC_2A-14A-66A_n260K
DC_2A-14A-66A_n260L
DC_2A-14A... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.44 14A-30A-66A_n260M | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.44.1 Operating bands for DC | Table 5.1.44.1-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_14-30-66_n260
CA_14-30-66
n260
No
DC_14-30-66-66_n260
CA_14-30-66
n260
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.44.2 Configuration for DC | Table 5.1.44.2-1: Inter-band EN-DC configurations of 3 LTE band + 1 NR band
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_14A-30A-66A_n260A
DC_14A-30A-66A_n260G
DC_14A-30A-66A_n260H
DC_14A-30A-66A_n260I
DC_14A-30A-66A_n260J
DC_14A-30A-66A_n260K
DC_14A-30A-66A_n260L
DC... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.46 DC_1-8-42_n77 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.46.1 Operating bands for EN-DC | Table 5.1.46.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_1-8-42_n77
CA_1-8-42
n77
DC_1_n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.46.2 Configurations for EN-DC | Table 5.1.46.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_1A-8A-42A_n77A
DC_1A_n77A
DC_8A_n77A
CA_1A-8A-42A
n77A
DC_1A-8A-42C_n77A
DC_1A_n77A
DC_8A_n77A
CA_1A-8A-42C
n77A
5.1.46.3 ∆TIB and ∆RIB values
For DC_1-8-42_n77... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.46.4 REFSENS requirements | Co-existence study for DC_1-8-42_n77 was covered by the studies for the fallback modes of DC_1-8_n77, DC_1-42_n77 and DC_8-42_n77.
No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.47 DC_3-8-42_n77 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.47.1 Operating bands for EN-DC | Table 5.1.47.1-1: Band combinations EN-DC (four bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_3-8-42_n77
CA_3-8-42
n77
DC_3_n77 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.47.2 Configurations for EN-DC | Table 5.1.47.2-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_3A-8A-42A_n77A
DC_3A_n77A
DC_8A_n77A
CA_3A-8A-42A
n77A
DC_3A-8A-42C_n77A
DC_3A_n77A
DC_8A_n77A
CA_3A-8A-42C
n77A
5.1.47.3 ∆TIB and ∆RIB values
For DC_3-8-42_n77... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.47.4 REFSENS requirements | Co-existence study for DC_3-8-42_n77 was covered by the studies for the fallback modes of DC_3-8_n77, DC_3-42_n77 and DC_8-42_n77.
No additional MSD requirement need to be defined for this dual connectivity configuration. |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.48 DC_3-7-8_n1, DC_3-3-7-8_n1, DC_3-7-7-8_n1, DC_3-3-7-7-8_n1 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.48.1 Operating bands for DC | Table 5.1.48.1-1: Band combinations EN-DC (three bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_3-7-8_n1
CA_3-7-8
n1
DC_3_n1
DC_3-3-7-8_n1
CA_3-3-7-8
n1
DC_3_n1
DC_3-7-7-8_n1
CA_3-7-7-8
n1
DC_3_n1
DC_3-3-7-7-8_n1
CA_3-3-7-7-8
n1
DC_3_n1 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.48.2 Configuration for DC | Table 5.1.48.2-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA configuration
NR configuration
DC_3A-7A-8A_n1A
DC_3A_n1A, DC_7A_n1A,
DC_8A_n1A
CA_3A-7A-8A
n1A
DC_3C-7A-8A_n1A
DC_3C_n1A, DC_7A_n1A, DC_8A_n1A
CA_3C-7A-8A
n1A
DC_3A-3A-7A-8A_n1A
DC_3A_n1A, DC_... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.48.3 Co-existence Studies | Based on co-existence studies of DC_3-7_n1, DC_3-8_n1 and DC_7-8_n1, as captured in TR 37.716-21-11, own Rx impacts on the 3rd band are the following:
- 5th order IMD generated by dual uplink of Band 7 + Band n1 may fall into own Rx of band 8. However, based on the studies for DL CA_1A-7A-8A paired with CA_1A-7A in TR ... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.48.5 REFSENS requirements | No additional MSD requirement is needed.
5.1.49 DC_3-7-40_n1
5.1.49.1 Operating bands for EN-DC
Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-7-40_n1
CA_3-7-40
n1
5.1.49.2 Configuration for EN-DC
Table 5.5B.4.3-1: Inter-band EN-DC configurations (four... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.50 DC_2-46-66_n41 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.50.1 Operating bands for DC | Table 5.1.50.1-1: Band combinations EN-DC (three bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-46-66_n41
CA_2-46-66
n41
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.50.2 Configuration for DC | Table 5.1.50.2-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
DC_2A-46A-66A_n41A
DC_2A-46C-66A_n41A
DC_2A-46D-66A_n41A
DC_2A_n41A
DC_66A_n41A
5.1.50.3 ∆TIB and ∆RIB values
The TIB,c and RIB,c values are derived from lower order combinations.
Table 5.1.50.3-1: ΔTIB,c
E-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.51 DC_2-46-66_n71 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.51.1 Operating bands for DC | Table 5.1.51.1-1: Band combinations EN-DC (three bands)
EN-DC Band
E-UTRA Band
NR Band
Single UL allowed
DC_2-46-66_n71
CA_2-46-66
n71
No |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.51.2 Configuration for DC | Table 5.1.51.2-1: Inter-band EN-DC configurations (three bands)
EN-DC
configuration
Uplink EN-DC
configuration
DC_2A-46A-66A_n71A
DC_2A-46C-66A_n71A
DC_2A-46D-66A_n71A
DC_2A_n71A
DC_66A_n71A
5.1.51.3 ∆TIB and ∆RIB values
The TIB,c and RIB,c values are derived from lower order combinations.
Table 5.1.51.4-1: ΔTIB,c
E-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.52.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_3-28-41_n78
CA_3-28-41
n78
DC_3_n78 |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.52.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
Configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_3A-28A-41A_n78A
DC_3A-28A-41C_n78A
DC_3A_n78A
DC_28A_n78A
DC_41A_n78A
DC_41C_n78A
CA_ 3A-28A-41A
CA_ 3A-28A-41C
n78A
5.1.52.3 ∆TIB and ∆RIB values
Table 6.2B.4.2.3.3-... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.53.1 Operating bands for EN-DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA CA band
NR band
Single UL allowed
DC_28-41-42_n78
CA_28-41-42
n78
no |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.53.2 Configuration for EN-DC | Table 5.5B.4.3-1: Inter-band EN-DC configurations (four bands)
EN-DC
configuration
Uplink EN-DC
configuration
(NOTE 1)
E-UTRA CA configuration
NR band
DC_28A-41A-42A_n78A
DC_28A-41C-42A_n78A
DC_28A-41A-42C_n78A
DC_28A-41C-42C_n78A
DC_28A_n78A
DC_41A_n78A
DC_41C_n78A
DC_42A_n78A
DC_42C_n78A
CA_ 28A-41A-42A
CA_ 28A-41C-4... |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.54 1-7-8_n78 | |
6f4cd24d580b0cdd9e7f0209ec2f2aeb | 37.716-31-11 | 5.1.54.1 Operating bands for DC | Table 5.2B.4.3-1: Band combinations EN-DC (four bands)
EN-DC band
E-UTRA Band
NR Band
Single UL allowed
DC_1-7-8_n781
CA_1-7-8
n78
No
NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.