4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.8.5 Test requirements
At step3, when the UE is powered up or switched on, UE shall: - initiate the PS attach procedure with information elements specified in the above Expected Sequence. At step6, when power is switched off before ATTACH ACCEPT message is received, UE shall: - abort the PS attach procedure and perform the PS detach procedur...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.9 PS attach / abnormal cases / PS detach procedure collision
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.9.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.9.2 Conformance requirement
1) When a DETACH REQUEST message is received by the UE (any cause except re-attach) while waiting for an ATTACH ACCEPT message, the UE shall terminate the PS attach procedure and continue with the PS detach procedure. 2) When a DETACH REQUEST message is received by the UE (cause re-attach) while waiting for an ATTACH A...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.9.3 Test purpose
To test the behaviour of the UE in case of procedure collision.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.9.4 Method of test
Initial condition System Simulator: One cell operating in network operation mode II. The SIB1 IE "CN domain specific NAS system information", for the CS Domain, is set to value "00 00" (T3212 value is set to 0 and ATT flag is set to FALSE). User Equipment: The UE has a valid P-TMSI-1 and RAI-1. The UE has been register...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.9.5 Test requirements
At step3, when the UE is powered up or switched on, UE shall: - initiate the PS attach procedure with information elements specified in the above Expected Sequence. UE shall perform the following actions depending on the Detach type in the DETACH REQUEST message. Case1) Detach type = 're-attach not required' GMM cause ...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.10 PS attach / abnormal cases / Failure due to non-integrity protection
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.10.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.10.2 Conformance requirement
Except the messages listed below, no layer 3 signalling messages shall be processed by the receiving MM and GMM entities or forwarded to the CM entities, unless the security mode control procedure is activated for that domain. - GMM messages: - AUTHENTICATION & CIPHERING REQUEST - AUTHENTICATION & CIPHERING REJECT - ID...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.10.3 Test purpose
To verify that the UE ignores NAS signalling messages when the security mode procedure is not activated.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.10.4 Method of test
Initial Conditions System Simulator: One cell operating in network operation mode II. The SIB1 IE "CN domain specific NAS system information", for the CS Domain, is set to value "00 00" (T3212 value is set to 0 and ATT flag is set to FALSE). User Equipment: The UE has a valid IMSI. If the UE is in UE operation mode A, ...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.10.5 Test requirements
At step4, when the UE is powered on or switched on, UE shall: - initiate the PS attach procedure with information elements specified in the above Expected Sequence. At step9, UE shall; - ignore the first ATTACH ACCEPT message. At step11, UE shall; - re-transmit ATTACH REQUEST message after expiry of timer T3310. At st...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.11 PS attach / accepted / follow-on request pending indicator set
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.11.1 Definition and applicability
UE which supports follow-on request procedure.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.11.2 Conformance requirement
1) In UMTS, if the MS wishes to prolong the established PS signalling connection after the GPRS attach procedure, it may set a follow-on request pending indicator on. 2) In UMTS, the network should prolong the PS signalling connection if the mobile station has indicated a follow-on request pending in ATTACH REQUEST. Th...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.11.3 Test purpose
To test the behaviour of the UE if the follow-on request pending indicator can be set on during the attach procedure. The following cases are identified: 1) follow-on request pending indicator may be set to indicate further signalling messages from the UE 2) follow-on request pending indicator not set, no further signa...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.11.4 Method of test
Initial condition System Simulator: 1 cell, operating in network operation mode II. The SIB1 IE "CN domain specific NAS system information", for the CS Domain, is set to value "00 00" (to prevent repeated CS domain registration and/or IMSI Detach by UEs in operation mode A). User Equipment: The UE is in GMM-state "GMM-...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.11.5 Test requirements
At step 8 the UE shall send an ATTACH REQUEST with FOR bit set to 1 At step 21 the UE shall send an ATTACH REQUEST with FOR bit set to 0.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.12 PS attach / abnormal cases / access barred due to domain specific access restriction for PS domain
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.12.1 Definition
This test case is applicable for Rel-5 UEs supporting DSAC and Rel-6 or later UEs.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.12.2 Conformance requirement
TS24.008 4.1.1.2.2 If the PS or CS domain is barred because of domain specific access control, a GPRS MS operating in mode A or B in a network that operates in mode II or III shall use the MM specific procedures or GMM specific procedures, respectively, in the domain which is unbarred. If the MS detects that a domain c...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.12.3 Test purpose
Test purpose To test the behaviour of the UE in case of domain specific access control for PS domain.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.12.4 Method of test
Initial condition An access class x (0-15) is arbitrarily chosen. The USIM is programmed with this access class x. The SS informs the UE that the PS domain specific access class x is barred in the cell. System Simulator: One cell operating in network operation mode II. PS domain specific access class x is barred. The S...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.12.5 Test requirements
At step4, when the SS indicates that PS domain specific access class x is barred, the UE shall: - not perform a PS attach procedure. At step7, when the SS indicates that PS domain specific access class x is not barred, the UE shall: - initiate the PS attach procedure.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.13 NITZ / GMM/ Time zone, Time and DST Handling
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.13.1 Definition
To check that the UE correctly handles time zone, time and DST.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.13.2 Conformance requirement
The feature Network Identities and Timezone shall make it possible for a serving PLMN to transfer its current identity, universal time, DST and LTZ to MSs, and for the MS to store and use this information. Each one of these elements is optional. The feature significantly enhances roaming as it enables the accurate indi...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.13.3 Test purpose
To verify that a UE supporting any of the NITZ Time related feature (Local Time Zone, Universal Time and DST IE (and thus GMM Information) is able to handle them properly.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.13.4 Method of test
Related ICS/IXIT statements Support of FDD Yes/No. Support of PS bearer service Yes/No. - Support of Switch on off button Yes/No. - Support of Automatic GPRS attach procedure at switch on or power on Yes/No. - Support of NITZ DST Yes/No. - Support of NITZ Universal Time for PLMN Yes/No. - Support of NITZ Local Time Zon...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.13.5 Test requirements
In step 6, 16 and 24 the UE populates the supported fields with the correct values.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.14 NITZ / GMM/ NITZ Parameters Storage and Deletion
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.14.1 Definition
To check that the UE correctly stores and deletes NITZ parameters.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.14.2 Conformance requirement
The feature Network Identities and Timezone shall make it possible for a serving PLMN to transfer its current identity, universal time, DST and LTZ to MSs, and for the MS to store and use this information. Each one of these elements is optional. The feature significantly enhances roaming as it enables the accurate indi...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.14.3 Test purpose
To verify that a UE supporting any of the NITZ Name related feature (Short or Full PLMN name and thus GMM Information) is able to handle the names properly and does not erase the PLMN name sent using NITZ procedure at switch off.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.14.4 Method of test
Related ICS/IXIT statements Support of FDD Yes/No. Support of PS bearer service Yes/No. - Support of Switch on off button Yes/No. - Support of Automatic GPRS attach procedure at switch on or power on Yes/No. - Support of NITZ Full name for PLMN Yes/No. - Support of NITZ Short name for PLMN Yes/No. Initial conditions S...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.14.5 Test requirements
In step 7 the UE populates the supported fields with the correct values. In step 16 the UE still contains the supported fields with the values as received in step 7.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.15 NITZ / GMM/ / MM and GMM Signalling
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.15.1 Definition
To check that the UE correctly stores NITZ parameters and displays the latest received NITZ parameters.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.15.2 Conformance requirement
The feature Network Identities and Timezone shall make it possible for a serving PLMN to transfer its current identity, universal time, DST and LTZ to MSs, and for the MS to store and use this information. Each one of these elements is optional. The feature significantly enhances roaming as it enables the accurate indi...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.15.3 Test purpose
To verify that a UE supporting NITZ (any of the Fields) is able to handle both MM INFORMATION and GMM INFORMATION messages and those parameters set in the latest message override the previous ones.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.15.4 Method of test
Related ICS/IXIT statements Support of FDD Yes/No. Support of PS bearer service Yes/No. - Support of Switch on off button Yes/No. - Support of Automatic GPRS attach procedure at switch on or power on Yes/No. - Support of NITZ DST Yes/No. - Support of NITZ Universal Time for PLMN Yes/No. - Support of NITZ Local Time Zon...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.15.5 Test requirements
In step 8, 16 and 24 the UE populates the supported fields with the correct received values.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.16 PS attach / EAB active
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.16.1 Definition
Test to verify that the UE does not perform PS attach if the network broadcast EAB and EAB is enabled in the UE.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.16.2 Conformance requirement
- For generic location updating, GPRS attach and routing area updating procedures the mobile station shall evaluate the control information for: - common access control (as specified in 3GPP TS 44.018 [84], 3GPP TS 44.060 [76], and 3GPP TS 25.331 [23c]); - domain specific access control (as specified in 3GPP TS 44.018 ...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.16.3 Test purpose
To verify that the UE does not perform PS attach if the network broadcast EAB and EAB is enabled in the UE
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.16.4 Method of test
Initial conditions: - System Simulator: - One cell operating in network operation mode II. - The SIB1 IE "CN domain specific NAS system information", for the CS Domain, is set to value "00 00" (T3212 value is set to 0 and ATT flag is set to FALSE to prevent repeated CS domain registration and/or IMSI Detach by UEs in o...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.1.16.5 Test requirement
At step 4, The UE shall not initiate a PS attach procedure as access class x is barred in EAB information. At step 6, The UE shall transmit a RRC CONNECTION REQUESTmessage on cell B to initiate a PS attach procedure.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2 Combined PS attach
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.1 Combined PS attach / PS and non-PS attach accepted
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.1.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.1.2 Conformance requirement
1) If the network accepts the combined PS attach procedure (signalled by an IMSI) and allocates a P-TMSI, the UE shall acknowledge the P-TMSI and continue communication with the P-TMSI. 2) If the network accepts the combined PS attach procedure (signalled by P-TMSI) and reallocates a new P-TMSI, the UE shall acknowledg...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.1.3 Test purpose
To test the behaviour of the UE if the network accepts the PS attach procedure. The following cases are identified: 1) P-TMSI / P-TMSI signature is allocated; 2) P-TMSI / P-TMSI signature is reallocated; 3) Old P-TMSI / P-TMSI signature is not changed; 4) Mobile terminating CS call is allowed with IMSI; 5) Mobile termi...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.1.4 Method of test
Initial condition System Simulator: One cell operating in network operation mode I. ATT flag is set to 0. User Equipment: The UE has a valid IMSI. Related ICS/IXIT statements Support of PS service Yes/No UE operation mode A Yes/No Switch off on button Yes/No Automatic PS attach procedure at switch on or power on Y...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.1.5 Test requirements
At step 3, when the UE is powered up or switched on, UE shall: - initiate the PS attach procedure with information elements specified in the above Expected Sequence. Case 1) SS accept the combined PS attach procedure (signalled by an IMSI) and allocates a P-TMSI. At step5, UE shall - send the ATTACH COMPLETE message. A...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.2 Combined PS attach / PS only attach accepted
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.2.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.2.2 Conformance requirement
1) If the network accepts the combined PS attach procedure, but GMM cause code 'IMSI unknown in HLR' is sent to the UE the User Equipment shall delete the stored TMSI, LAI and CKSN. The User Equipment shall consider USIM invalid for non-PS services until power is switched off or USIM is removed. 2) If the network accep...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.2.3 Test purpose
Test purpose 1 To test the behaviour of the UE if the network accepts the PS attach procedure with indication PS only, GMM cause 'IMSI unknown in HLR'. Test purpose 2 To test the behaviour of the UE which does not support an automatic MM IMSI attach if the network accepts the PS attach procedure with indication PS only...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.2.4 Method of test
Proc 1: Test procedure 1 Initial condition System Simulator: One cell operating in network operation mode I. User Equipment: The UE has a valid IMSI. Related ICS/IXIT statements Support of PS service Yes/No UE operation mode A Yes/No Switch off on button Yes/No Automatic PS attach procedure at switch on or power on ...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.2.5 Test requirements
Test requirements for Test porpose1 At step3, when the UE is powered up or switched on, UE shall: - initiate the Combined PS attach procedure with information elements specified in the above Expected Sequence. At step7, when the UE receives the paging message for CS domain, UE shall: - not respond to the paging messag...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.3 Combined PS attach / PS attach while IMSI attach
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.3.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.3.2 Conformance requirement
If the PS UE is already attached for non-PS services by the MM specific attach procedure, but wants to perform an attach for PS services, the combined PS attach procedure is performed. Reference 3GPP TS 24.008 clause 4.7.3.2.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.3.3 Test purpose
To test the behaviour of the UE if PS attach performed while IMSI attached.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.3.4 Method of test
Initial condition System Simulator: One cell operating in network operation mode I. ATT flag is set. User Equipment: The UE has a valid TMSI-1, P-TMSI-1 and RAI-1. Related ICS/IXIT statements Support of PS service Yes/No UE operation mode A Yes/No Switch off on button Yes/No Automatic PS attach procedure at switch ...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.3.5 Test requirements
UE is already attached for non-PS service with the MM specific attach procedure. At step5, UE shall: - not respond to the paging message for PS domain. At step7, when the UE is requested to attach for PS services, UE shall: - perform the combined PS attach procedure. At step13, UE shall: - respond to the paging message...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.4 Combined PS attach / rejected / IMSI invalid / illegal ME
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.4.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.4.2 Conformance requirement
1) If the network rejects a combined PS attach procedure from the User Equipment with the cause 'Illegal ME', the User Equipment shall consider USIM invalid for PS and non-PS services until power is switched off or USIM is removed. 2) If the network rejects a combined PS attach procedure from the User Equipment with th...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.4.3 Test purpose
To test the behaviour of the UE if the network rejects the combined PS attach procedure of the UE with the cause 'Illegal ME'.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.4.4 Method of test
Initial condition System Simulator: Three cells (not simultaneously activated), cell A in MCC1/MNC1/LAC1/RAC1 (RAI-1) and cell B in MCC1/MNC1/LAC1/RAC2 (RAI-4), cell C in MCC2/MNC1/LAC1/RAC1(RAI-2). All three cells are operating in network operation mode I. NB: i) Cell C will be mapped to Cell 4 as found in TS 34.108 c...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.4.5 Test requirements
At step4, when the UE is powered up or switched on, UE shall: - initiate the combined PS attach procedure with the information elements specified in the above Expected Sequence. At step7, 9 and 16, when the UE receives the paging message for CS domain, UE shall, - not respond to the paging message for CS domain. At ste...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.5 Combined PS attach / rejected / PS services and non-PS services not allowed
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.5.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.5.2 Conformance requirement
1) If the network rejects a combined PS attach procedure from the User Equipment with the cause 'GPRS services and non-GPRS services not allowed', the User Equipment shall consider USIM invalid for PS and non-PS services until power is switched off or USIM is removed. 2) If the network rejects a combined PS attach proc...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.5.3 Test purpose
To test the behaviour of the UE if the network rejects the combined PS attach procedure of the UE with the cause 'GPRS services and non-GPRS services not allowed'.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.5.4 Method of test
Initial condition System Simulator: - Two cells (not simultaneously activated), cell A in MCC1/MNC1/LAC1/RAC1 (RAI-1) and cell B in MCC2/MNC1/LAC1/RAC1 (RAI-2). Both cells are operating in network operation mode I. NB: i) Cell B will be mapped to Cell 4 as found in TS 34.108 clause 6.1.4.1. User Equipment: - The UE has...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.5.5 Test requirements
At step4, when the UE is powered up or switched on, UE shall: - initiate the combined PS attach procedure with the information elements specified in the above Expected Sequence. At step8 and 15, when the UE receives the paging message for CS domain, UE shall: - not respond to the paging message for CS domain. At step10...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.6 Combined PS attach / rejected / PS services not allowed
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.6.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.6.2 Conformance requirement
1) If the network rejects a combined PS attach procedure from the User Equipment with the cause 'GPRS services not allowed', the User Equipment shall consider USIM invalid for PS services until power is switched off or USIM is removed. 2) If the network rejects a combined PS attach procedure from the User Equipment wit...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.6.3 Test purpose
To test the behaviour of the UE if the network rejects the PS attach procedure of the UE with the cause 'GPRS services not allowed'.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.6.4 Method of test
Initial condition System Simulator: Two cells (not simultaneously activated), cell A in MCC1/MNC1/LAC1/RAC1 (RAI-1) and cell B in MCC2/MNC1/LAC1/RAC1 (RAI-2). Both cells are operating in network operation mode I. ATT flag set to 1 NB: i) Cell B will be mapped to Cell 4 as found in TS 34.108 clause 6.1.4.1. User Equipme...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.6.5 Test requirements
At step3, when the UE is powered up or switched on, UE shall: - initiate the combined PS attach procedure with the information elements specified in the above Expected Sequence. At step6, if the UE is PS class A, UE shall: - perform the MM IMSI attach procedure. At step11, 22 and 36, when the UE receives the paging mes...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.8 Combined PS attach / abnormal cases / attempt counter check / miscellaneous reject causes
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.8.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.8.2 Conformance requirement
1) When a combined PS attach procedure is rejected with the attempt counter less than five, the User Equipment shall repeat the combined PS attach procedure after T3311 timeout. 2) When a combined PS attach procedure is rejected with the attempt counter five, the User Equipment shall delete the stored TMSI, LAI, CKSN, ...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.8.3 Test purpose
To test the behaviour of the UE with respect to the attempt counter.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.8.4 Method of test
Initial condition System Simulator: One cell operating in network operation mode I. User Equipment: The UE has a valid TMSI, P-TMSI and RAI. Related ICS/IXIT statements Support of PS service Yes/No UE operation mode A Yes/No Automatic PS attach procedure at switch on or power on Yes/No Switch off on button Yes/No Tes...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.8.5 Test requirements
At step3, when the UE is powered up or switched on, UE shall: - initiate the combined PS attach procedure with the information elements specified in the above Expected Sequence. UE shall perform the following actions depending on the conditions described below. Case1) A combined PS attach procedure is rejected with the...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.9 Combined PS attach / abnormal cases / PS detach procedure collision
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.9.1 Definition
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.9.2 Conformance requirement
1) When a DETACH REQUEST message is received by the UE (any cause except re-attach) while waiting for an ATTACH ACCEPT message or ATTACH REJECT message, the UE shall terminate the combined PS attach procedure and continue with the combined PS detach procedure. 2) When a DETACH REQUEST message is received by the UE (cau...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.9.3 Test purpose
To test the behaviour of the UE in case of procedure collision.
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.9.4 Method of test
Initial condition System Simulator: One cell operating in network operation mode I. User Equipment: The UE has valid TMSI, P-TMSI and RAI. UE is Idle Updated. Related ICS/IXIT statements Support of PS service Yes/No UE operation mode A Yes/No Switch off on button Yes/No Automatic PS attach procedure at switch on or p...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.9.5 Test requirements
At step3, when the UE is powered up or switched on, UE shall: - initiate the combined PS attach procedure with the information elements specified in the above Expected Sequence. UE shall perform the following actions depending on the Detach type described below. Case1) Detach type is not re-attach At step6, UE shall: -...
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.10 Combined PS attach / abnormal cases / access barred due to paging permission with access control
4251e2eb3ecde7c73983ce7a4175ddf3
34.123-1
12.2.2.10.1 Definition
This test case is applicable for Rel-8 or later UEs.