hash stringlengths 32 32 | doc_id stringlengths 7 13 | section stringlengths 3 121 | content stringlengths 0 2.2M |
|---|---|---|---|
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.5.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.5.3 Conformance requirements | The conformance requirements covered in the present TC are specified in CEN EN 16072 [8], clause 7.10.1 paragraph 1 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.2.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.5.4 Test description | 7.1.1.5.4.1 Pre-test conditions Preamble 1: Ignition ON. 7.1.1.5.4.2 Test procedure sequence Table 7.1.1.5.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger automatic eCall - - - - 2 IF PE eCall only IVS THEN Steps of the generic procedure for network registration (clause 6.1.2.1)... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.6.1 Test Purpose (TP) | (1a) with { connection established } ensure that { when { new automatic eCall triggered } then { eCall in progress was not disconnected } } (1b) with { connection established } ensure that { when { new manual eCall triggered } then { eCall in progress was not disconnected } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.6.2 Test applicability | This test case applies to all types of PE eCall IVS. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 42 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.6.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.11 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.2.2. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.6.4 Test description | 7.1.1.6.4.1 Pre-test conditions Preamble 2: Ignition ON and IVS is in mobile network coverage; automatically triggered eCall in progress. 7.1.1.6.4.2 Test procedure sequence Table 7.1.1.6.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message - EXCEPTION: Steps 1a to 1b describe behaviour that d... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.7 CTP 1.1.2.3 Post-side-crash performance of automatic trigger - IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.7.1 Test Purpose (TP) | (1) with { ignition ON and IVS is in good mobile network coverage } ensure that { when { automatic eCall triggered } then { MSD successfully transmitted and E112 - voice connection established } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.7.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.7.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 6.1.1 paragraph 4; clause 7.10.1 paragraph 4, paragraph 6, paragraph 8; clause 7.5 paragraph 1, paragraph 2, paragraph 3, paragraph 4 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.2.3. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 43 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.7.4 Test description | 7.1.1.7.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in good mobile network coverage. In case the IVS is able to distinguish different kinds of crashes, a lateral shock to test the IVS crash robustness can be generated in two ways: Either a lateral crash according to Directive 96/27/EC [14] (or equivalent... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.8 CTP 1.1.2.4 Post-frontal-crash performance of automatic trigger - IVS | In case the IVS is able to distinguish different kinds of crashes, the crash type in the pre-test conditions (clause 7.1.1.7.4.1 of the present document) differ. Else this test is equivalent to the TC specified in clause 7.1.1.7 (CTP 1.1.2.3). |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.9 CTP 1.1.2.5 Performance of automatic trigger - different crash types - IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.9.1 Test Purpose (TP) | (1) with { ignition ON and IVS is in good mobile network coverage } ensure that { when { automatic eCall triggered } then { MSD successfully transmitted and voice connection established } } (2) with { E112 - voice connection } ensure that { when { call clear down indicated } then { IVS disconnects } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.9.2 Test applicability | This test case applies to all types of PE eCall IVS. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 44 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.9.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 6.1.1, paragraph 4; clause 7.10.1, paragraph 4, paragraph 6, paragraph 8; clause 7.5, paragraph 1, paragraph 2, paragraph 3, paragraph 4 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.2.5. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.9.4 Test description | 7.1.1.9.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in good mobile network coverage. 7.1.1.9.4.2 Test procedure sequence Table 7.1.1.9.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger automatic eCall - - - - 2 IF PE eCall only IVS THEN Steps of the generic procedur... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.10 CTP 1.1.3.1 eCall manually activated - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.10.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage } ensure that { when { manual eCall triggered } then { Visual or audible indication provided and eCall successfully established } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.10.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.10.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.10.2 paragraph 2 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.3.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.10.4 Test description | 7.1.1.10.4.1 Pre-test conditions Preamble 1: Ignition ON. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 45 7.1.1.10.4.2 Test procedure sequence Table 7.1.1.10.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger manual eCall - - - - 2 IF PE eCall only IVS THEN Steps of the generic procedure ... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.11.1 Test Purpose (TP) | (1a) with { ignition ON and IVS is in mobile network coverage and manual eCall is in progress } ensure that { when { new automatic eCall triggered } then { eCall in progress was not disconnected } } (1b) with { ignition is ON and IVS is in mobile network coverage and manual eCall is in progress } ensure that { when { n... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.11.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.11.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.11 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.3.2. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.11.4 Test description | 7.1.1.11.4.1 Pre-test conditions Preamble 3: Ignition ON and IVS is in mobile network coverage; manually triggered eCall in progress. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 46 7.1.1.11.4.2 Test procedure sequence Table 7.1.1.11.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message - EXCEPTION: S... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.12 CTP 1.1.4.1 Test eCall activated - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.12.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage } ensure that { when { test eCall from the IVS is triggered by using E.164 number provisioned by USIM for test calls} then { test eCall has been setup with correct non-emergency number} } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.12.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.12.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.2.2 paragraph 1 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.4.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.12.4 Test description | 7.1.1.12.4.1 Pre-test conditions Preamble 1: Ignition ON. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 47 7.1.1.12.4.2 Test procedure sequence Table 7.1.1.12.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger test eCall - - - - 2 IF PE eCall only IVS THEN Steps of the generic procedure fo... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.13 CTP 1.1.5.1 Network registration - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.13.1 Test Purpose (TP) | (1a) with { ignition ON and IVS in mobile network coverage } ensure that { when { automatic eCall triggered } then { network registration successful } } (1b) with { ignition ON and IVS in mobile network coverage } ensure that { when { manual eCall triggered } then { network registration successful } } (1c) with { ignit... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.13.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.13.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clauses 7.3.2 and 7.3.4 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.5.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.13.4 Test description | 7.1.1.13.4.1 Pre-test conditions Preamble 1: Ignition ON. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 48 7.1.1.13.4.2 Test procedure sequence Table 7.1.1.13.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message - EXCEPTION: Steps 1a to 1c describe behaviour that depends on the test configuration; the... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.14.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage and automatically triggered eCall is in progress } ensure that { when { attempt to terminate eCall manually } then { eCall in progress was not disconnected } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.14.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.14.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.10.3 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.5.2. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.14.4 Test description | 7.1.1.14.4.1 Pre-test conditions Preamble 2: Ignition ON and IVS is in mobile network coverage; automatically triggered eCall is in progress. 7.1.1.14.4.2 Test procedure sequence Table 7.1.1.14.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 attempt to terminate eCall manually <-- - - -... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.15.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage and manually triggered eCall is in progress } ensure that { when { attempt to terminate eCall manually } then { eCall in progress was not disconnected } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.15.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.15.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.10.3 paragraph 2 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.5.3. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.15.4 Test description | 7.1.1.15.4.1 Pre-test conditions Preamble 3: Ignition ON and IVS is in mobile network coverage; manually triggered eCall is in progress. 7.1.1.15.4.2 Test procedure sequence Table 7.1.1.15.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Attempt to terminate eCall manually <-- - - - 2 Ch... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.16.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage and automatically triggered eCall is in progress } ensure that { when { vehicle Power OFF } then { eCall in progress was not disconnected } } ETSI ETSI TS 103 412 V1.3.1 (2020-03) 50 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.16.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.16.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.10.1 paragraph 5 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.5.4. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.16.4 Test description | 7.1.1.16.4.1 Pre-test conditions Preamble 2: Ignition ON and IVS is in mobile network coverage; automatically triggered eCall is in progress. 7.1.1.16.4.2 Test procedure sequence Table 7.1.1.16.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Vehicle Power OFF <-- Manufacturer dependent ... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.17.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage and manually triggered eCall is in progress } ensure that { when { vehicle Power OFF } then { eCall in progress was not disconnected } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.17.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.17.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.11 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.5.5. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.17.4 Test description | 7.1.1.17.4.1 Pre-test conditions Preamble 3: Ignition ON and IVS is in mobile network coverage; manually triggered eCall is in progress. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 51 7.1.1.17.4.2 Test procedure sequence Table 7.1.1.17.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Vehicle P... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.18 Void | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.18a CTP 1.1.5.6 Priority over conflicting communication - PE eCall capable IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.18a.1 Test Purpose (TP) | (1a) with { ignition ON and IVS in mobile network coverage and a conflicting communication is running on IVS } ensure that { when { automatic eCall triggered } then { conflicting communication is stopped, HMI alert is provided and all necessary components of the IVS are unrestricted available and IVS starts connection ... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.18a.2 Test applicability | This test case applies to of PE eCall capable IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.18a.3 Conformance requirements | The conformance requirements of CEN EN 16072 [8], clause 7.4 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.5.6. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.18a.4 Test description | 7.1.1.18a.4.1 Pre-test conditions Preamble 4 for PE eCall capable IVS Testing: Ignition ON and IVS is in good mobile network coverage; no error is detected on the IVS, a conflicting communication is running on the IVS. 7.1.1.18a.4.2 Test procedure sequence Table 7.1.1.18a.4.2-1: Main behaviour Step Procedure Message Se... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.18b CTP 1.1.5.6 Priority over conflicting communication - PE eCall only IVS | No test required. As per definition, on eCall only IVS there can be no conflicting communication. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 53 7.1.1.19 CTP 1.1.5.7 Network registration is re-tried when network registration attempt was not successful - PE eCall IVS No test required. (This eventuality is covered by ETSI TS 1... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20a CTP 1.1.6.1 Mute IVS and vehicle audio - PE eCall capable IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20a.1 Test Purpose (TP) | (1a) with { ignition ON and IVS in mobile coverage } ensure that { when { automatic eCall is triggered } then { IVS starts connection establishment } } (1b) with { ignition ON and IVS in mobile coverage } ensure that { when { manual eCall is triggered } then { IVS starts connection establishment } } (1c) with { ignitio... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20a.2 Test applicability | This test case applies to PE eCall capable IVS. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 54 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20a.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.2.1 and CEN EN 16072 [8], clause 7.17.3 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.6.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20a.4 Test description | 7.1.1.20a.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. 7.1.1.20a.4.2 Test procedure sequence Table 7.1.1.20a.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message - EXCEPTION: Steps 1a to 1b describe behaviour that depends on the test configuration; the... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20b CTP 1.1.6.1 Mute IVS and vehicle audio - PE eCall only IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20b.1 Test Purpose (TP) | (1a) with { ignition ON and IVS in mobile coverage } ensure that { when { automatic eCall is triggered } then { IVS registers on the network and starts connection establishment } } (1b) with { ignition ON and IVS in mobile coverage } ensure that { when { manual eCall is triggered } then { IVS registers on the network a... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20b.2 Test applicability | This test case applies to PE eCall only IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20b.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.2.1 and CEN EN 16072 [8], clause 7.17.3 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.6.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.20b.4 Test description | 7.1.1.20b.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 56 7.1.1.20b.4.2 Test procedure sequence Table 7.1.1.20b.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message - EXCEPTION: Steps 1a to 1b describe behaviour th... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.21.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage } ensure that { when { automatic eCall triggered } then { "Service Category Request" message information element (IE) set to automatically initiated eCall (AIeC) } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.21.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.21.3 Conformance requirements | Reference requirements of CEN EN 16454 [1] CTP 1.1.7.1. The conformance requirements of CEN EN 16062 [6], clause 7.3.6 paragraph 2 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.7.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.21.4 Test description | 7.1.1.21.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 57 7.1.1.21.4.2 Test procedure sequence Table 7.1.1.21.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger automatic eCall - - - - 2 Check: Is the "S... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.22.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage } ensure that { when { manual eCall from the IVS is triggered } then { "Service Category Request" message information element (IE) set to manually initiated eCall (MIeC) } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.22.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.22.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.3.6 paragraph 2 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.8.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.22.4 Test description | 7.1.1.22.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. 7.1.1.22.4.2 Test procedure sequence Table 7.1.1.22.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger manual eCall - - - - 2 IF PE eCall only IVS THEN Steps of the generic procedure for... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.23 CTP 1.1.9.1 Set-up TS11 call to test number - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.23.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage } ensure that { when { test eCall from the IVS is triggered by using E.164 number provisioned by USIM for test calls} then { test eCall has been setup with correct non-emergency number and is routed to PSAP test point} } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.23.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.23.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.2.2 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.9.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.23.4 Test description | 7.1.1.23.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. 7.1.1.23.4.2 Test procedure sequence Table 7.1.1.23.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger test eCall - - - - 2 IF PE eCall only IVS THEN Steps of the generic procedure for n... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.24a.1 Test Purpose (TP) | (1) with { IVS is in mobile network coverage (limited service condition as specified in ETSI 124.008)} ensure that { when {test eCall at the IVS is triggered } then { IVS does not initiate a test eCall} } (2a) with { IVS is in mobile network coverage (limited service condition as specified in ETSI 124.008) } ensure tha... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.24a.2 Test applicability | This test case applies to all types of PE eCall IVS which support an exchangeable or reconfigurable SIM/USIM. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.24a.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clauses 7.3.5 and 7.14.2 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.10.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.24a.4 Test description | 7.1.1.24a.4.1 Pre-test conditions A SIM/USIM supporting the limited service condition shall be used (i.e. forbidden PLMN). PE eCall capable IVS: Preamble 5: Ignition ON and IVS is in mobile network coverage, limited service condition. PE eCall only IVS: Preamble 1: Ignition ON and IVS is in mobile network coverage. ETS... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.24b.1 Test Purpose (TP) | (1) with { IVS is in mobile network coverage (limited service condition as specified in ETSI 124.008)} ensure that { when {test eCall at the IVS is triggered } then { IVS does not initiate a test eCall} } (2a) with { IVS is in mobile network coverage (limited service condition as specified in ETSI 124.008) } ensure tha... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.24b.2 Test applicability | This test case applies to all types of PE eCall IVS which do not support an exchangeable or reconfigurable SIM/USIM. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.24b.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clauses 7.3.5 and 7.14.2 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.10.1. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 61 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.24b.4 Test description | 7.1.1.24b.4.1 Pre-test conditions Preamble 1 (Steps 1 to 3, applies to eCall only and PE eCall capable IVS): Ignition ON and IVS is in mobile network coverage. 7.1.1.24b.4.2 Test procedure sequence Table 7.1.1.24b.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 IF PE eCall capable IVS: ... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.25.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established } ensure that { when { call is dropped before MSD transfer is completed (before LL-ACK is sent)} then { at least 1 redial attempt has to be made, all redial attempts have to be completed within 2 minutes } } (1b) with { manual eCall in state call established } ensur... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.25.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.25.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.12.3, CEN EN 16072 [8], clauses 6.17.2 and 6.17.3 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.10.2. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.25.4 Test description | 7.1.1.25.4.1 Pre-test conditions Depending on call type (automatic or manual) Preamble 2 or Preamble 3 is used. 7.1.1.25.4.2 Test procedure sequence Table 7.1.1.25.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 IVS sends initiation signal --> PUSH-REQ - - 2 PSAP requests MSD <-- SEND M... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.26 CTP 1.1.10.3 Duration of eCall Initiation signal - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.26.1 Test Purpose (TP) | (1a) with { ignition ON and IVS in mobile network coverage } ensure that { when { automatic eCall triggered and no SEND MSD message is received} then { eCall is established and the initiation signal shall not persist for longer than 2 s } } (1b) with { ignition ON and IVS in mobile network coverage } ensure that { when... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.26.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.26.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.4.2 paragraph 2; annex A table A.1 T3 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.10.3. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.26.4 Test description | 7.1.1.26.4.1 Pre-test conditions Depending on call type, (automatically or manually) Preamble 2 or Preamble 3 is used. 7.1.1.26.4.2 Test procedure sequence Table 7.1.1.26.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 IVS sends initiation signal --> PUSH-REQ - - 2 Check: eCall is estab... |