25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.27.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage } ensure that { when { automatic eCall from the IVS is triggered } then { MSD contains automaticActivation = true and testCall = false) } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.27.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.27.3 Conformance requirements | The conformance requirements of CEN EN 15722 [12], clause 6.3.1 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.11.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.27.4 Test description | 7.1.1.27.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 64 7.1.1.27.4.2 Test procedure sequence Table 7.1.1.27.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger automatic eCall - - - - 2 IF PE eCall only... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.28.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage } ensure that { when { manual eCall from the IVS is triggered } then { MSD contains automaticActivation = false and testCall = false) } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.28.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.28.3 Conformance requirements | The conformance requirements of CEN EN 15722 [12], clause 6.3.1 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.12.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.28.4 Test description | 7.1.1.28.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 65 7.1.1.28.4.2 Test procedure sequence Table 7.1.1.28.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger manual eCall - - - - 2 IF PE eCall only IV... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.29 CTP 1.1.13.1 Send MSD with indicator set to "Test eCall" - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.29.1 Test Purpose (TP) | (1) with { ignition ON and IVS in mobile network coverage } ensure that { when { test eCall from the IVS is triggered } then { MSD contains testCall = true) } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.29.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.29.3 Conformance requirements | The conformance requirements of CEN EN 15722 [12], clause 6.3.1 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.13.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.29.4 Test description | 7.1.1.29.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 66 7.1.1.29.4.2 Test procedure sequence Table 7.1.1.29.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger test eCall - - - - 2 IF PE eCall only IVS:... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.30 CTP 1.1.14.1 Verify MSD transfer - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.30.1 Test Purpose (TP) | (1a) with { ignition ON and IVS in mobile network coverage } ensure that { when { automatic eCall from the IVS is triggered } then { eCall is established and the initiation signal is received before PSAP timer T4 expires } } (1b) with { ignition ON and IVS in mobile network coverage } ensure that { when { manual eCall ... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.30.2 Test applicability | This test case applies to all types of PE eCall IVS. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 67 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.30.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clauses 7.4 and 7.5 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.14.1. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.30.4 Test description | 7.1.1.30.4.1 Pre-test conditions Depending on call type (automatic, manual or test eCall) Preamble 2, Preamble 3 or Preamble 11 is used. 7.1.1.30.4.2 Test procedure sequence Table 7.1.1.30.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1a Trigger automatic eCall - - - - 1b Trigger manual... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.31 CTP 1.1.14.2 Un-mute IVS audio when AL-ACK received - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.31.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established } ensure that { when { MSD transfer is completed and AL-ACK is sent } then { IVS un-mutes audio } } ETSI ETSI TS 103 412 V1.3.1 (2020-03) 68 (1b) with { manual eCall in state call established } ensure that { when { MSD transfer is completed and AL-ACK is sent } then... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.31.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.31.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.5.1 paragraph 3 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.31.4 Test description | 7.1.1.31.4.1 Pre-test conditions Depending on call type (automatic, manual or test eCall) Preamble 2, Preamble 3 or Preamble 11 is used. 7.1.1.31.4.2 Test procedure sequence Table 7.1.1.31.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 eCall in progress according to steps 2-7 of generi... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.32 CTP 1.1.15.1 Establish voice link to PSAP - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.32.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established } ensure that { when { MSD transfer is completed and AL-ACK is sent } then { Two-way speech is possible } } (1b) with { manual eCall in state call established } ensure that { when { MSD transfer is completed and AL-ACK is sent } then { Two-way speech is possible } }... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.32.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.32.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.5.1 paragraph 3 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.32.4 Test description | 7.1.1.32.4.1 Pre-test conditions Depending on call type (automatic, manual or test eCall) Preamble 2, Preamble 3 or Preamble 11 is used. 7.1.1.32.4.2 Test procedure sequence Table 7.1.1.32.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 eCall in progress according to steps 2-7 of generi... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.33.1 Test Purpose (TP) | (1a) with { automatically triggered eCall is in progress, MSD is transferred and 2-way voice connection established } ensure that { when { PSAP requests MSD again} then { IVS mutes audio, IVS sends MSD and MSD is received by PSAP before timer T8 expires } } (1b) with { manually triggered eCall is in progress, MSD is tr... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.33.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.33.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.6.2 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.15.2. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.33.4 Test description | 7.1.1.33.4.1 Pre-test conditions Preamble 6, call type (automatic, manual, test) to be specified. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 71 7.1.1.33.4.2 Test procedure sequence Table 7.1.1.33.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 PSAP requests MSD <- SEND MSD 2 PSAP starts time... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.34.1 Test Purpose (TP) | (1a) with { ignition ON and IVS in mobile network coverage } ensure that { when { automatic eCall triggered, no SEND MSD is received} then { 2-way speech connection is established after expiry of timer T5 } } (1b) with { ignition ON and IVS in mobile network coverage } ensure that { when { manual eCall triggered no SEN... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.34.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.34.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clauses 7.4.4 and 7.12.10; annex A table A.1 T5 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.15.3. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 72 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.34.4 Test description | 7.1.1.34.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS is in mobile network coverage. 7.1.1.34.4.2 Test procedure sequence Table 7.1.1.34.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1a Trigger automatic eCall - - - - 1b Trigger manual eCall 1c Trigger test eCall 2 IF PE eCal... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.35.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established } ensure that { when { MSD is received, LL-ACK is sent and no AL-ACK is sent } then { after timer T6 expiry two-way speech is possible } } (1b) with { manual eCall in state call established } ensure that { when { MSD is received, LL-ACK is sent and no AL-ACK is sent... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.35.2 Test applicability | This test case applies to all types of PE eCall IVS. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 73 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.35.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clauses 7.5.3 and 7.12.5.2; annex A, table A.1 T6 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.35.4 Test description | 7.1.1.35.4.1 Pre-test conditions Depending on call type (automatic, manual or test eCall) Preamble 2, Preamble 3 or Preamble 11 is used. 7.1.1.35.4.2 Test procedure sequence Table 7.1.1.35.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 eCall in progress according to steps 2-6 of generi... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.36.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established } ensure that { when { MSD is received, no LL-ACK and no AL-ACK is sent } then { after timer T7 expiry two-way speech is possible } } (1b) with { manual eCall in state call established } ensure that { when { MSD is received, no LL-ACK and no AL-ACK is sent } then { ... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.36.2 Test applicability | This test case applies to all types of PE eCall IVS. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 74 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.36.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.4.7; annex A table A.1 T7 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.36.4 Test description | 7.1.1.36.4.1 Pre-test conditions Depending on call type (automatic, manual or test eCall) Preamble 2, Preamble 3 or Preamble 11 is used. 7.1.1.36.4.2 Test procedure sequence Table 7.1.1.36.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 2 IVS sends initiation signal --> PUSH-REQ 3 PSAP re... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.37 CTP 1.1.16.1 Clear down call automatically - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.37.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established } ensure that { when { MSD transfer is completed } then { 2-way speech is possible } } (1b) with { manual eCall in state call established } ensure that { when { MSD transfer is completed } then { 2-way speech is possible } } (1c) with { test eCall in state call esta... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.37.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.37.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.5 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.37.4 Test description | 7.1.1.37.4.1 Pre-test conditions Preamble 6. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 76 7.1.1.37.4.2 Test procedure sequence Table 7.1.1.37.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Check: Is 2-way speech possible? 1a, 1b, 1c P 2 PSAP hangs-up call according to generic procedure (cl... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.38 CTP 1.1.16.2 IVS clears down the eCall upon T2 expiry - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.38.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established and IVS timer T2 started } ensure that { when { timer T2 expires } then { call is released } } (1b) with { manual eCall in state call established and IVS timer T2 started } ensure that { when { timer T2 expires } then { call is released } } (1c) with { test eCall in... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.38.2 Test applicability | This test case applies to all types of PE eCall IVS. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 77 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.38.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clauses 7.9; 7.12.3, 7.12.16 and 7.3.1; annex A table A.1 T2 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.38.4 Test description | 7.1.1.38.4.1 Pre-test conditions Preamble 1. 7.1.1.38.4.2 Test procedure sequence Table 7.1.1.38.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1a Trigger automatic eCall - - - - 1b Trigger manual eCall - - - - 1c Trigger test eCall - - - - 2 IF PE eCall only IVS THEN Steps of the generi... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.39 CTP 1.1.16.3 IVS registers recent eCalls - PE eCall IVS | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.39.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established } ensure that { when { MSD transfer is completed and AL-ACK is sent with CLEAR DOWN and tester requests time stamp AL-ACK information } then { IVS provides means to access the correctly stored time stamp of the AL-ACK information } } (1b) with { manual eCall in stat... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.39.2 Test applicability | This test case applies to all types of PE eCall IVS for which the tester has access to data stored in the IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.39.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.5.2 paragraph 3 also CEN EN 16072 [8], clause 7.17.4 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.39.4 Test description | 7.1.1.39.4.1 Pre-test conditions Depending on call type (automatic, manual or test eCall) Preamble 2, Preamble 3 or Preamble 11 is used. 7.1.1.39.4.2 Test procedure sequence Table 7.1.1.39.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 eCall in progress according to steps 2-6 of generi... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.40.1 Test Purpose (TP) | (1) with { eCall completed and timer T9 running } ensure that { when { IVS is called back } then { IVS answers call automatically } } (2) with { callback answered automatically by IVS } ensure that { when { audio/voice line has been reconnected } then { IVS loudspeaker and microphone are activated and 2-way speech is p... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.40.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.40.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.10 (including point c) and CEN EN 16072 [8], clause 7.17.3 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.40.4 Test description | 7.1.1.40.4.1 Pre-test conditions Preamble 7. 7.1.1.40.4.2 Test procedure sequence Table 7.1.1.40.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Trigger Callback from PSAP - - - - 2 Steps 1-8 of the generic procedure for call back to the IVS according to generic procedure (clause 6.1.2.... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.41.1 Test Purpose (TP) | (1a) with { automatic eCall in state call established } ensure that { when { call is dropped before MSD transfer is completed (before LL-ACK is sent) } then { at least 1 redial attempt has to be made, all redial attempts have to be completed within 2 minutes } } (1b) with { manual eCall in state call established } ensu... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.41.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.41.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.10 (including point c) and CEN EN 16072 [8], clause 7.17.3 shall apply for this TC. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.41.4 Test description | 7.1.1.41.4.1 Pre-test conditions Depending on call type (automatic, manual or test eCall) Preamble 2, Preamble 3 or Preamble 11 is used. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 81 7.1.1.41.4.2 Test procedure sequence Table 7.1.1.41.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 IVS sends... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.42.1 Test Purpose (TP) | (1) with { call back is in progress and 2-way voice connection established } ensure that { when { PSAP requests MSD} then { IVS mutes audio, IVS sends MSD and MSD is received by PSAP before timer T8 expires } } (2) with { audio muted and valid MSD received at PSAP } ensure that { when { Format check of MSD at PSAP is s... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.42.2 Test applicability | This test case applies to all types of PE eCall IVS. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 82 |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.42.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.6.3 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.17.3. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.42.4 Test description | 7.1.1.42.4.1 Pre-test conditions Preamble 9. 7.1.1.42.4.2 Test procedure sequence Table 7.1.1.42.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 PSAP requests MSD <- SEND MSD 2 PSAP starts timer T8. 3 Check: IVS mutes audio. 1 P 4 IVS sends MSD -> MSD TX 5 PSAP received valid MSD messag... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.43.1 Test Purpose (TP) | (1a) with { ignition ON and IVS is in mobile coverage } ensure that { when { automatic eCall is triggered } then { IVS registers on the network and starts connection establishment } } (1b) with { ignition ON and IVS is in mobile coverage } ensure that { when { manual eCall is triggered } then { IVS registers on the net... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.43.2 Test applicability | This test case applies to all types of PE eCall IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.43.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.9, especially paragraph 6; clause 7.10 (c); annex A, table A.1 T9; CEN EN 16072 [8], clause 7.17.3 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.17.4. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.1.43.4 Test description | 7.1.1.43.4.1 Pre-test conditions Preamble 1. 7.1.1.43.4.2 Test procedure sequence Table 7.1.1.43.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1a Trigger automatic eCall - - - - 1b Trigger manual eCall - - - - 1c Trigger test eCall - - - - 2 Steps of the generic procedure for network re... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.1.1 Test Purpose (TP) | (1) with { ignition OFF } ensure that { when { Vehicle Power ON and IVS waited for 60 seconds } then { IVS NAD has not attempted to register with MNO and IE "Establishment cause" is not set to "Registration" for 120 seconds } } |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.1.2 Test applicability | This test case applies to PE eCall only IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.1.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.1.4, paragraph 1 and clause 7.1.6, paragraph 1 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.1.2. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.1.4 Test description | 7.1.2.1.4.1 Pre-test conditions Ignition OFF; IVS has privileges to register only on this network. 7.1.2.1.4.2 Test procedure sequence Table 7.1.2.1.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message 1 Vehicle Power ON - - - - 2 Wait 60 seconds - - - - 3 Check: Is IE "Establishment cause" se... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.3.1 Test Purpose (TP) | (1a) with { ignition ON and IVS in mobile network coverage and IVS was not registered on a PLMN } ensure that { when { automatic eCall triggered } then { successful PLMN registration } } (1b) with { ignition ON and IVS in mobile network coverage and IVS was not registered on a PLMN } ensure that { when { manual eCall t... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.3.2 Test applicability | This test case applies to PE eCall only IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.3.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clauses 6 (c); 7.3.4; 7.3.5 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.10.4. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.3.4 Test description | 7.1.2.3.4.1 Pre-test conditions Preamble 1: Ignition ON and IVS was not registered on a PLMN. 7.1.2.3.4.2 Test procedure sequence Table 7.1.2.3.4.2-1: Main behaviour Step Procedure Message Sequence TP Verdict I - T Message - EXCEPTION: Steps 1a to 1b describe behaviour that depends on the test configuration; the "lower... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.4.1 Test Purpose (TP) | (1) with { eCall completed and timer T9 running} ensure that { when { IVS is called back after 55 minutes } then { IVS answers call automatically } } (2) with { callback having been performed after 55 minutes and timer T9 having elapsed} ensure that { when { IVS de-registers } then { IVS transmits IMSI DETACH INDICATIO... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.4.2 Test applicability | This test case applies to PE eCall only IVS. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.4.3 Conformance requirements | The conformance requirements of CEN EN 16062 [6], clause 7.9 shall apply for this TC. The test shall complete CEN EN 16454 [1] CTP 1.1.17.5. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.2.4.4 Test description | 7.1.2.4.4.1 Pre-test conditions Preamble 7: Ignition ON and IVS is in mobile network coverage; IVS has been programmed with the non-emergency number to be used for test calls; eCall of applicable type has been established and cleared down; timer T9 is running. 7.1.2.4.4.2 Test procedure sequence Table 7.1.2.4.4.2-1: Ma... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.4.1 MSD transmission time for different channel conditions | |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.4.1.1 Definition | These tests shall validate that a PE eCall IVS passes the end-to-end minimum performance requirements in terms of MSD failure rate and MSD transmission time. The test configurations are adapted from ETSI TS 126 269 [5], clauses 5.2.1.1, 5.2.1.2 and 5.2.1.3, which were dedicated for simulative environments, in order to ... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.4.1.2 Conformance requirements | The average MSD transmission time for the different codec types, rates and radio channel conditions shall not exceed the requirement given in table 7.1.4.1.5-1 for PSAP-PUSH-RTT or table 7.1.4.1.5-2 for PSAP-PULL-RTT depending on the chosen method. The values define the requirement in seconds. The MSD success rate shal... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.4.1.3 Test purpose | To verify that the PE eCall IVS does not exceed the conformance requirement under TU3 propagation conditions. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.4.1.4 Method of test | IVS under test and reference PSAP shall be setup to be connected via a concatenated radio channel and network simulators. GNSS position may be provided through a pre-stored position or through an external GNSS simulator. For the in-band modem performance tests, repeated tests shall be conducted under different radio an... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.4.1.5 Test requirements | Table 7.1.4.1.5-1: Conformance Requirements for different codec and radio conditions, MSD transmission time according to definition of PSAP-PUSH-RTT (in seconds) Codec Type GSM- FR GSM- HR AMR-NB AMR- WB Codec Mode Radio condition 13,0 5,6 12,2 10,2 7,95 7,4 6,7 5,9 5,15 4,75 12,65 C/I = 1 dB 7,6 C/I = 4 dB 5,6 6,0 6,0... |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.4.2 MSD transmission time in noisy conditions | Tests according to ETSI TS 126 269 [5], clause 5.2.1.4 are for further study. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.1.4.3 MSD transmission time with scaling of PCM signals | Tests according to ETSI TS 126 269 [5], clause 5.2.1.5 are for further study. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.2 Mobile Network Operators | Tests according to CEN EN 16454 [1], clause 10 are for further study. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.3 PSAP Systems | Tests according to CEN EN 16454 [1], clause 11 are for further study. |
25496abe4432c36f845a6284ed8c24b1 | 103 412 | 7.4 TPS-eCall | Tests according to CEN EN 16454 [1], clause 12 are for further study. ETSI ETSI TS 103 412 V1.3.1 (2020-03) 91 Annex A (informative): Recommended test case applicability The applicability of each individual test is identified in table A-1. This is just a recommendation based on the purpose for which the test case was w... |
0f5c55d533a36ebfa34c5531c31ba182 | 103 434 | 1 Scope | The present document focuses on Gigabit Home Networking for Very High Speed Internet video distribution using video transcoding for the distribution of HD and UHD video streams over SISO and MIMO PLT networks [i.1]. The present document defines the transcoding of HD and UHD video for improvement of the house coverage o... |