b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.1.2 Initial conditions | • Terminal off. • In order to test voltage without any interrupt, a mute UICC is to be used for this test (e.g. a physically mute UICC, or a simulated/emulated mute UICC, or no UICC at all, etc.). • There is a resistor load of 165 Ω across C1 (Vcc) and C5 (Gnd) or the simulated/emulated mute UICC has a current sink of ... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.1.3 Test procedure | Step Direction Description RQ 1 T Terminal remains off 2 User T Trigger the Terminal to be turned on 3 T UICC Activate contact VCC (C1) with voltage class C' RQ01_0303 4 UICC Stay mute 5 T If the Terminal initiates the UICC activation procedure specified in ETSI TS 102 221 [2]: Maintain VCC between 1,65 V and 1,95 ... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.2.1 Test execution | The test procedure shall only be executed if class B is supported by the terminal. The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.2.2 Initial conditions | • Terminal off. • In order to test voltage without any interrupt, a mute UICC is to be used for this test (e.g. a physically mute UICC, or a simulated/emulated mute UICC, or no UICC at all, etc.). • There is a resistor load of 165 Ω across C1 (Vcc) and C5 (Gnd) or the simulated/emulated mute UICC has a current sink of ... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.2.3 Test procedure | Step Direction Description RQ 1 T Terminal remains off 2 User T Trigger the Terminal to be turned on 3 T UICC Activate contact VCC (C1) with voltage class C' RQ01_0303 4 UICC Stay mute 5 T If the Terminal initiates the UICC activation procedure specified in ETSI TS 102 221 [2]: Maintain VCC between 1,65 V and 1,95 ... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.3 Void | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.4 Void | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.5 Void | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.6 Test case 6: USB Interface Activation | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.6.1 Test execution | The test procedure shall be executed once for each of following parameters: • USB attachment time by the UICC in step a1 (after Vcc high): - 11 ms ± 1 ms. - 19 ms ± 1 ms. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.6.2 Initial conditions | • Terminal is connected to UICC simulator, but none of the contacts are activated. ETSI ETSI TS 102 922-1 V7.3.0 (2021-02) 36 Release 7 |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.6.3 Test procedure | If USB Reset signal is not provided 5 s after Vcc is activated, then the Terminal fails the test. NOTE: 5 s is a reasonable time-delay for the USB reset to occur. Step Direction Description RQ 1 User T Trigger the Terminal to activate contact VCC (C1) with voltage class C'. 2 T UICC Activate contact VCC (C1) with v... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.4.1.7 Void | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5 Initialization Tests | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.1 Configuration | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.1.1 Test Case 1: Set address Test at USB Full Speed | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.1.1.1 Test execution | The test procedure shall be executed for each of the following parameters: • There are no test case-specific parameters for this test case. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.1.1.2 Initial conditions | • Terminal is connected to UICC simulator supporting ICCD Version B Control Transfer. • Device in Default state. ETSI ETSI TS 102 922-1 V7.3.0 (2021-02) 37 Release 7 |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.1.1.3 Test procedure | Step Direction Description RQ 0 T UICC Optional exchange between terminal and UICC may occur at this level prior to step 1 This could include requests for a partial Device Descriptor 1 T UICC Send Set Address with Device Address not 0 RQ04_0301 RQ05_0101 2 T UICC Maintains activated voltage to UICC and continues... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2 Power Negotiation | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.1 Test Case 1: Power Negotiation support | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.1.1 Test execution | The test procedure shall be executed once for each of following value of bMaxCurrent indicated by the UICC when returning the Get Interface Request response: • bMaxCurrent = "03" (Maximum current required 6 mA) • bMaxCurrent = "05" (Maximum current required 10 mA) |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.1.2 Initial conditions | • Terminal is connected to UICC simulator, but none of the contacts are activated. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.1.3 Test procedure | Step Direction Description RQ 1 User T Trigger the terminal to activate the IC USB Interface 2 T UICC Send Get Interface Power Request RQ04_0302 RQ05_0201 3 UICC T Return Get Interface Power Request Response with: bVoltageClass = "06" (indicating Class C' and B supported) class B activation not preferred bM... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.2 Test Case 2: Power Negotiation, Voltage Class not supported | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.2.1 Test execution | The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.2.2 Initial conditions | • The USB interface has been activated. ETSI ETSI TS 102 922-1 V7.3.0 (2021-02) 38 Release 7 |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.2.3 Test procedure | Step Direction Description RQ 1 User T Trigger the terminal to send Get Interface Power Request 2 T UICC Send Get Interface Power Request 3 UICC T Return Get Interface Power Request Response indicating that the Voltage Class currently provided by the terminal is NOT supported 4 T UICC Deactivate RQ04_0106 |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.3 Test Case 3: Power Negotiation, Class B Activation preferred | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.3.1 Test execution | The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.3.2 Initial conditions | • The USB interface has been activated. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.3.3 Test procedure | Step Direction Description RQ 1 User T Trigger the terminal to send Get Interface Power Request 2 T UICC Send Get Interface Power Request 3 UICC T Return Get Interface Power Request Response with Class B activation preferred The terminal shall perform either steps a1 to a3, or steps b1 to b4 a1 T UICC Send Set ... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.4 Test Case 4: Power Negotiation with more than minimum current | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.4.1 Test execution | The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.4.2 Initial conditions | • Terminal is connected to UICC simulator, but none of the contacts are activated. ETSI ETSI TS 102 922-1 V7.3.0 (2021-02) 39 Release 7 |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.2.4.3 Test procedure | Step Direction Description RQ 1 User T Trigger the terminal to activate the IC USB Interface 2 T UICC Send Get Interface Power Request 3 UICC T Return Get Interface Power Request Response with: bVoltageClass = "06" (indicating Class C' and B supported) class B activation not preferred bMaxCurrent = "20" (Ma... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.3 Resume Time Negotiation | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.3.1 Test Case 1: Resume Time Negotiation | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.3.1.1 Test execution | The test procedure shall only be executed if Resume Time Request is supported by the terminal. The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.3.1.2 Initial conditions | • APDU all commands have had a complete response. • Terminal is connected to UICC simulator containing only ICCD Control B Configuration. • ICCD Control B Configuration selected. • Terminal is ready to send Resume Time Request. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.5.3.1.3 Test procedure | Step Direction Description RQ 1 T UICC Check that no suspending of the interface happens before the resume time negotiation RQ05_0301 2 T UICC Send Resume Time Request RQ05_0302 3 UICC T Response to Resume Time Request with the following parameters: bMinResTime = '1E' bMinSofTokens = 5 bmRemWakeup = Remote ... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6 Descriptors | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.1 Standard-Descriptors | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.1.1 Device Descriptor | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.1.1.1 Test Case 1: Device Descriptor Test | 6.6.1.1.1.1 Test execution The test procedure shall be executed for each of the following parameters: • There are no test case-specific parameters for this test case. 6.6.1.1.1.2 Initial conditions • Terminal is connected to UICC simulator supporting ICCD Version B Control Transfer Descriptors as detailed in clause 4.4... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.1.2 Configuration and Interface Descriptors | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.1.2.1 Test Case 1: ICCD Control Transfer configuration Test, single interface | 6.6.1.2.1.1 Test execution The test procedure shall be executed for each of the following parameters: • There are no test case-specific parameters for this test case. 6.6.1.2.1.2 Initial conditions • Terminal is connected to UICC simulator supporting ICCD Version B Control Transfer Descriptors as detailed in clause 4.4... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.1.2.2 Test Case 2: Multiple ICCD configuration, single interface test | 6.6.1.2.2.1 Test execution The test procedure shall be executed for each of the following parameters: • With Configuration Descriptor ICCD control B first, then Configuration Descriptor ICCD Bulk as defined in clause 4.4.6.2, Multiple Configuration, Single Interface. • With Configuration Descriptor ICCD Bulk first then... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.1.2.3 Test Case 3: Multiple configuration, multiple interfaces test | 6.6.1.2.3.1 Test execution The test procedure shall be executed for each of the following parameters: • There are no test case-specific parameters for this test case. 6.6.1.2.3.2 Initial conditions • Terminal is connected to UICC simulator supporting ICCD Version B Control Transfer and Bulk Transfer with EEM and Mass S... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.1.2.4 Test Case 4: Configuration Descriptor and no ICCD support from the USB UICC | 6.6.1.2.4.1 Test execution The test procedure shall be executed for each of the following parameters: • There are no test case-specific parameters for this test case. 6.6.1.2.4.2 Initial conditions • Terminal is connected to UICC simulator not supporting ICCD Descriptors as detailed in clause 4.4.6.5, Single Configurat... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.2 Class Specific-Descriptors | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.2.1 ICCD Class Descriptor | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.6.2.1.1 Test Case 1: ICCD Class Descriptor Test | 6.6.2.1.1.1 Test execution The test procedure shall be executed for each of the following parameters: • There are no test case-specific parameters for this test case. 6.6.2.1.1.2 Initial conditions • Device in Addressed state. • Device Descriptor read. • Terminal is connected to UICC supporting ICCD Version B Control T... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7 Protocol Stack and Higher Level | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1 ICCD - APDU based UICC Applications | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1.1 Test Case 1: ICCD Control B Interface | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1.1.1 Test execution | The test procedure shall be executed for each of the following parameters: • There are no test case-specific parameters for this test case. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1.1.2 Initial conditions | • Terminal is connected to UICC simulator supporting ICCD Version B Control Transfer Descriptors as detailed in clause 4.4.6.1, Single Configuration, Single Interface. • Device in Addressed and Configured state. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1.1.3 Test procedure | Step Direction Description RQ 1 T UICC Set the USB-IC to initial conditions by sending ICC_POWER_OFF RQ06_0101 2 T UICC Send SLOT_STATUS request RQ06_0101 3 UICC T Return SLOT_STATUS (USB-ICC is virtually not present) 4 T UICC Exit the initial state by sending ICC_POWER_ON RQ06_0101 5 T UICC Send DATA_BLOCK r... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1.2 Test Case 2: ICCD Bulk Interface | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1.2.1 Test execution | The test procedure shall only be executed if ICCD Bulk Interface is supported by the terminal. The test procedure shall be executed for each of the following parameters: • There are no test case-specific parameters for this test case. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1.2.2 Initial conditions | • Terminal is connected to UICC simulator supporting ICCD Version B Control Transfer and Bulk Transfer Descriptors as detailed in clause 4.4.6.2, Multiple Configuration, Single Interface. • Device in Addressed and Configured state. ETSI ETSI TS 102 922-1 V7.3.0 (2021-02) 44 Release 7 |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.1.2.3 Test procedure | Step Direction Description RQ 1 T UICC Send PC_to_RDR_IccPowerOff RQ06_0102 2 UICC T Return RDR_to_PC_SlotStatus (USB-ICC is virtually not present) 3 T UICC Send PC_to_RDR_IccPowerOn RQ06_0102 4 UICC T Return RDR_to_PC_DataBlock containing valid ATR 5 T UICC Send PC_to_RDR_XfrBlock (APDU Command) RQ06_0102 6 ... |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.2 EEM - Ethernet Emulation Model | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.2.1 Test Case 1: EEM Echo Test | |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.2.1.1 Test execution | The test procedure shall only be executed if EEM Interface is supported. The test procedure shall be performed using complete configuration as defined in clause 4.4.6.3. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.2.1.2 Initial conditions | • Terminal is connected to UICC simulator supporting ICCD Version B Control Transfer and Bulk Transfer with EEM and Mass Storage Interface Descriptors as detailed in clause 4.4.6.3, Multiple Configuration, Multiple Interface. • Device is Addressed and in the Configured state. |
b2ebd9052bea1a749553916e67f136d5 | 102 922-1 | 6.7.2.1.3 Test procedure | Step Direction Description RQ 1 UICC T Send single EEM command packet with "Echo" 2 T UICC Return valid "Echo response" RQ06_0301 ETSI ETSI TS 102 922-1 V7.3.0 (2021-02) 45 Release 7 Annex A (informative): List of test cases for each conformance requirement RQ number Test clauses RQ01_0101 Not tested in the present... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 1 Scope | The present document defines the system requirements for a European Public Warning Service using the Cell Broadcast Service, defined in ETSI TS 123 041 [1], as a means of message distribution and delivery to User Equipment (UE). |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 2 References | |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 2.1 Normative references | References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. Referenced documents which a... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 2.2 Informative references | References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. NOTE: While any hyperlinks i... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 3 Definition of terms, symbols and abbreviations | |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 3.1 Terms | For the purposes of the present document, the following terms apply: amber alert: alert to seek help from citizens to find abducted children EU-ALERT: generic term for the European Public Warning Service NOTE: Specific Countries are identified by replacing the letters EU with the Country Identification letters in ISO 3... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 3.2 Symbols | Void. |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 3.3 Abbreviations | For the purposes of the present document, the following abbreviations apply: 5G NR 5G New Radio CBS Cell Broadcast Service CMAS Commercial Mobile Alert System CMSP Commercial Mobile Service Provider DBGF Device-Based Geo-Fencing ETWS Earthquake and Tsunami Warning System FCC Federal Commission for Communications GSM Ge... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 4 Background | |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 4.0 General | For the public authorities, warning the population on the occurrence of a possible disaster is one of their responsibilities. They will use for this purpose all means of communication, in relation with the specific features of the disaster (e.g. the level of risks, it can be forecast or not; the coverage is limited or ... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 4.1 Importance of NL-Alert | NL-Alert has been implemented as the first Public Warning Service in Europe which is additional to existing services like siren systems, radio and/or television, Internet, SMS, and social media. The Netherlands Government strongly believes in a multi-channel approach to optimize the reach of the service among the popul... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 4.2 Other countries supporting EU-Alert | After the Netherlands went live with NL-Alert in 2012, Lithuania went live a year later with LT-Alert and also Romania went live with RO-Alert. Directive (EU) 2018/1972 of the European Parliament and of the Council of 11 December 2018 established the European Electronic Communications Code, which was published in the O... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5 EU-Alert capabilities | |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.1 Language | The need to support Public Warning Messages in various languages is necessary for the European Public Warning System because there are many European countries that share borders where there is a frequent and significant movement of mobile subscribers across those borders, i.e. a high instance of international roaming. ... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.2 Message Types | |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.2.0 General | EU-Alert has identified the need for the following types of messages, and it is subject to regulatory requirements if all levels or only a subset of the levels are used in a country: • Alert messages to warn citizens of an imminent emergency situation • Advisory messages of lesser urgency • Amber alerts (child abductio... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.2.1 Message Identifiers | The use of CBS Message Identifiers defined in ETSI TS 123 041 [1] is one mechanism that would allow Message Types to be identified. Message Identifiers for EU-Alert are related to the level of the severity of the message and to the language. The use of EU-Alert message types is as follows. Table 1 Type Similar CMAS mes... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.3 Service activation | With regards to service activation, EU-Alert may be subject to local regulatory requirements, such as: • Provisioning of the UE by the operator with the service activated by default. • Activation of the Cell Broadcast capability in the UE remotely through the network (see ETSI TS 125 331 [5]). ETSI ETSI TS 102 900 V1.4... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.4 Bearer technology | The EU-Alert service is based on the Cell Broadcast Service as specified in ETSI TS 123 041 [1] and shall be supported on 2G as well as technologies beyond 2G. Since a Public Warning System is usually deployed for many years, future technologies beyond 5G, shall also provide a broadcast capability that fulfils the requ... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.5 Security considerations | For a reliable use of the Cell Broadcast service the user should have the highest possible confidence in the validity of the message received. As Cell Broadcast Service does not provide any capability for the UE to authenticate that the EU-Alert messages received are from a genuine source, it is possible that malicious... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.6 Delay Requirements | There are no strict delay requirements for PWS. From an operational point of view two transmissions of a 93 character warning message within 3 minutes could be sufficient. Each transmission represents the use of one language using an "EU" or a "legacy" Message Identifier. |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 5.7 Device-Based Geo-Fencing | Device-Based Geo-Fencing (DBGF) allows the presentation of the warning message to be limited to UEs that are inside the targeted warning notification area. This will effectively eliminate the effect of overshoot of the radio signal for cell broadcast outside the targeted warning notification area. DBGF is specified in ... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 6 UE specific aspects | |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 6.0 General UE aspects | It is assumed that at least the capabilities that are provided through the Cell Broadcast Service are supported by the UE. These capabilities are for example: • Support for CBS, regardless of if the UE is connected to a 2G, 3G, 4G or a 5G network. • Detection and suppression of duplicate messages. • Support for Class 0... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 6.1 UE requirements | |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 6.1.0 General UE requirements | UE requirements in this clause are related not only to EU-Alert messages, but to all message types, unless specifically mentioned otherwise. |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 6.1.1 Maintaining user preferences | The following are the requirements on the UE for the support of user preferences for EU-Alert: 1) The UE shall be able to maintain user alert opt-out selections for all Message Types, with the exception of EU-Amber and EU-Test for which an opt-in selection shall be available, and EU-Alert Level 1 for which no opt-out s... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 6.1.2 Presentation of the message | The following are the requirements on the UE for the presentation of EU-Alert messages: 1) The presentation of EU-Alert messages shall take priority over all other UE functions, but shall not pre-empt active voice or data sessions. 2) A momentary interruption of a voice or data session to alert the user that an EU-Aler... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 6.1.3 Feature behaviour | An EU-Alert message shall not pre-empt any active voice or data sessions, and it is desired feature behaviour of the UE that the UE shall alert the user that an EU-Alert message has been received with the alerting indication that is specific for EU-Alert messages, and the EU-Alert message shall be displayed immediately... |
63b12aae36a9c6b7dc4bd57915f0b569 | 102 900 | 6.2 Considerations for individuals with special needs | Special consideration shall be required in the UE receiving a PWS message for hearing impaired persons. Whilst a UE receiving a Public Warning Message is expected to give an unmistakeable audible warning sound, this is of no use to a hearing impaired person. The UE could of course "vibrate" in a special way but that wi... |
820e628e9b7939c14d7949fb74366cce | 102 950-3 | 1 Scope | The present document specifies the Abstract Test Suite (ATS) for the TTCN-3 conformance test suite, as defined in ETSI ES 201 873-1 [1] in compliance with the relevant guidance given in the pro forma for TTCN-3 reference test suite ETSI TS 102 950-2 [8]. The objective of the present document is to provide a basis for c... |
820e628e9b7939c14d7949fb74366cce | 102 950-3 | 2 References |