hash
stringlengths
32
32
doc_id
stringlengths
7
13
section
stringlengths
3
121
content
stringlengths
0
2.2M
cc725a86775f5379efd6316472d76bc0
102 922-2
5.6 Protocol stacks for USB UICC applications
Reference: ETSI TS 102 600 [1], clause 9. RQ number clause description RQ06_0101 9.1 All USB UICCs shall present at least one USB configuration descriptor with short APDU-level exchanges over Version B Control transfer with no Interrupt pipe as defined in the Smart Card ICCD specification [8]. RQ06_0102 9.1 Application...
cc725a86775f5379efd6316472d76bc0
102 922-2
5.7 USB Descriptors of a USB UICC
Reference: ETSI TS 102 600 [1], annex A. RQ number clause description RQ07_0101 A.1 The Standard device descriptor for a USB UICC shall be as defined in the Smart Card ICCD specification [8], with the specific values for the following entries: => bDeviceClass = 00h. => bDeviceSubClass = 00h. => bDeviceProtocol = 00h. R...
cc725a86775f5379efd6316472d76bc0
102 922-2
5.8 Assigned values for vendor specifIC_USB requests
Reference: ETSI TS 102 600 [1], annex B. No requirement in this clause.
cc725a86775f5379efd6316472d76bc0
102 922-2
6 Test cases
cc725a86775f5379efd6316472d76bc0
102 922-2
6.1 Void
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2 Physical Tests
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2.1 Test case 1: Dimensions of the UICC card
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2.1.1 Test execution
ETSI TS 102 221 [2] allows three kind of cards with different form factors: • ID1 - UICC: Defined in ETSI TS 102 221 [2], ISO/IEC 7810 [12] and ISO/IEC 7816-2 [13]. • Plug-in UICC: Defined in ETSI TS 102 221 [2]. • Mini - UICC: Defined in ETSI TS 102 221 [2]. ETSI ETSI TS 102 922-2 V7.1.0 (2025-10) 22 Release 7 The UIC...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2.1.2 Initial conditions
• Identify the dimension design for the kind of UICC card ETSI TS 102 221 [2], ISO/IEC 7810 [12] or ISO/IEC 7816-2 [13].
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2.1.3 Test procedure
Step Direction Description RQ 1 User Measure the dimensions of the card and the contacts and check if they perform the dimensions of the design. RQ02_0001
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2.2 Test case 2: Mechanical characteristics
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2.2.1 Test execution
The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2.2.2 Initial conditions
• None.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.2.2.3 Test procedure
Step Direction Description RQ 1 User The mechanical characteristics of the USB UICC are as defined in ETSI TS 102 221 [2]. RQ02_0001
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3 Basic Electrical Tests
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1 Supply Voltage Value
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.1 Test case 1: No connection for incorrect voltage class
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.1.1 Test execution
The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.1.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated. ETSI ETSI TS 102 922-2 V7.1.0 (2025-10) 23 Release 7
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.1.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact Vcc(C1) at 1,25 V ± 0,05 V. 2 UICC  T C4(IC_DP) and C8(IC_DM) set low and shall not show attachment. RQ03_0102
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.2 Test case 2: Reaction at Class C'
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.2.1 Test execution
The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.2.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.2.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact Vcc(C1) at 1,65 V. 2 UICC  T C4 (IC_DP)set high between 10 ms and 20 ms(tp1) after VOP (1,32 V) is reached. RQ03_0301 RQ03_0302
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.3 Test case 3: Reaction at Class B
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.3.1 Test execution
The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.3.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.3.1.3.3 Test procedure
Step Direction Description RQ 1 T   UICC Activate contact Vcc(C1) at 2,7 V. 2 UICC  T C4 (IC_DP)set high between 10 ms and 20 ms(tp1) after VOP (2,16 V) is reached. RQ03_0201 RQ03_0202 ETSI ETSI TS 102 922-2 V7.1.0 (2025-10) 24 Release 7
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4 Activation Tests
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1 Voltage class Activation
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1.1 Test case 1: Support of voltage classes C' and B
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1.1.1 Test execution
The test procedure shall be executed once for each of following parameters: • Voltage Class C'. • Voltage Class B.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1.1.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated. • The USB UICC contacts C2, C3 and C7 are connected to the Terminal simulator contacts C2, C3and C7. Terminal simulator Contacts C2, C3 and C7 are individually pulled down to C5 (GND).by a resistor of 50 kΩ.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1.1.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact VCC (C1) with voltage class according to parameter and maintain VCC. Start monitoring the power drawn by the UICC. 2 UICC Within 80 µs following establishment of a stable power supply, the USB UICC shall present a high impedance state on contacts C4 and C8. RQ02...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1.2 Test case 2: UICC detects non-USB Terminal
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1.2.1 Test execution
The test procedure shall be executed once for each of following parameters: • Voltage Class C'. • Voltage Class B.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1.2.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated. • The USB UICC contacts C2, C3, C6 and C7 are connected to the Terminal simulator contacts C2, C3 and C7. Terminal simulator Contacts C2, C3 and C7 are individually pulled down to C5 (GND).by a resistor of 50 kΩ. ETSI ETSI TS 102 922-2 V...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.1.2.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact VCC (C1) with voltage class according to parameter and maintain VCC. 2 UICC  T C4 is pulled up after 10 ms and before 20 ms after the power supply is stable. RQ02_0101 3 T  UICC C8 is driven High simultaneously with C4. 4 UICC Terminate the USB attachment and ...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2 Interface Selection/Activation
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.1 Test case 1: Activation of ETSI TS 102 221 interface only
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.1.1 Test execution
The test procedure shall be executed once for each of following parameters: • Voltage Class C. • Voltage Class B.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.1.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated. • The USB UICC is connected to the Terminal simulator and none of the contacts are activated. • The terminal simulator is simulating a fully functional ETSI TS 102 221 [2] only terminal.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.1.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact VCC (C1) with voltage class according to parameter and maintain Vcc 2 T  UICC Activate the rest of the ETSI TS 102 221 [2] interface contacts 3 UICC  T Send ATR: - The first TBi (i>2) after T = 15 indicates Inter-Chip USB. UICC-Terminal interface supported as ...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.2 Test case 2: USB Interface selection - ATR procedure
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.2.1 Test execution
The test procedure shall be executed once for each of following parameters: • Voltage Class C'. • Voltage Class B. ETSI ETSI TS 102 922-2 V7.1.0 (2025-10) 26 Release 7
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.2.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated. • The USB UICC is connected to the Terminal simulator and none of the contacts are activated.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.2.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact VCC (C1) with voltage class according to parameter and maintain Vcc. Start monitoring the power drawn by the UICC. 2 T  UICC Activate the rest of the ETSI TS 102 221 [2] interface contacts. 3 UICC  T Send ATR: - The first TBi (i>2) after T = 15 indicates Inter...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.3 Test case 3: USB Interface selection - USB procedure
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.3.1 Test execution
The test procedure shall be executed once for each of following parameters: • Voltage Class C'. • Voltage Class B.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.3.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated. • The USB UICC is connected to the Terminal simulator and none of the contacts are activated.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.3.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact VCC (C1) with voltage class according to parameter. 2 UICC  T C4 is pulled up after 10 ms and before 20 ms after the power supply is stable. RQ04_0205 3 T  UICC Send USB Reset signal. RQ04_0203 4 T  UICC Request the first 8 bytes of the Device Descriptor on D...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.4 Test case 4: USB Interface selection - Concurrent procedure
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.4.1 Test execution
The test procedure shall be executed once for each of following parameters: • Voltage Class C'. • Voltage Class B.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.4.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated. • The USB UICC is connected to the Terminal simulator and none of the contacts are activated.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.4.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact VCC (C1) with voltage class according to parameter and maintain Vcc and wait for a C4 pull-up. Start monitoring the power drawn by the UICC. 2 UICC  T C4 is pulled up after 10 ms and before 20 ms after the power supply is stable. RQ04_0205 3 T  UICC Activate t...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.5 Test case 5: Activation of ETSI TS 102 221 interface with PPS procedure
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.5.1 Test execution
The test procedure shall be executed once for each of following parameters: • Voltage Class C'. • Voltage Class B.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.5.2 Initial conditions
• Terminal simulator is connected to UICC, but none of the contacts are activated. • The USB UICC is connected to the Terminal simulator and none of the contacts are activated. ETSI ETSI TS 102 922-2 V7.1.0 (2025-10) 28 Release 7
cc725a86775f5379efd6316472d76bc0
102 922-2
6.4.2.5.3 Test procedure
Step Direction Description RQ 1 T  UICC Activate contact VCC (C1) with voltage class according to parameter and maintain VCC. 2 T  UICC Activate the rest of the ETSI TS 102 221 [2] interface contacts. 3 UICC  T Send ATR: - The first TBi (i>2) after T = 15 indicates Inter-Chip USB. UICC-Terminal interface supported a...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5 Initialization Tests
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1 Power Negotiation
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.1 Test case 1: Support of Get Interface power request current as requested
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.1.1 Test execution
The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.1.2 Initial conditions
• Device descriptor has been read. • No Power Negotiation executed.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.1.3 Test procedure
Step Direction Description RQ 1 T  UICC Send Get Interface Power Request. 2 UICC  T Return Get Interface Power Request Response. RQ05_0201 3 T  UICC Send Set Interface Power Request indicating the support of the activated voltage and at least current of bMaxCurent. 4 UICC  T Return response successful completion. R...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.2 Test case 2: Support of Get Interface power request wLength greater than 2
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.2.1 Test execution
The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case. ETSI ETSI TS 102 922-2 V7.1.0 (2025-10) 29 Release 7
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.2.2 Initial conditions
• Device descriptor has been read. • No Power Negotiation executed.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.2.3 Test procedure
Step Direction Description RQ 1 T  UICC Send Get Interface Power Request wLength = 4. 2 UICC  T Return Get Interface Power Request Response length = 2 bytes. RQ05_0203
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.3 Test case 3: Support of Set Interface power request minimum current
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.3.1 Test execution
The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.3.2 Initial conditions
• Device connected (no Power Negotiation executed). • Device descriptor has been read.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.1.3.3 Test procedure
Step Direction Description RQ 1 T  UICC Send Get Interface Power Request. 2 UICC  T Return Get Interface Power Request Response 3 T  UICC Send Set Interface Power Request indicating the support of the activated voltage and bMaxCurrent = 10 mA. 4 UICC  T Return response successful completion, and current consumption...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.2 Resume Time Negotiation
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.2.1 Test case 1: Resume Time Negotiation
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.2.1.1 Test execution
The test procedure shall be executed once for each of following parameters: • There are no test case-specific parameters for this test case.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.2.1.2 Initial conditions
• Device is Addressed and ICCD Control B Configuration selected. • The UICC has not been suspended. ETSI ETSI TS 102 922-2 V7.1.0 (2025-10) 30 Release 7
cc725a86775f5379efd6316472d76bc0
102 922-2
6.5.2.1.3 Test procedure
Step Direction Description RQ 1 T  UICC Send Resume Time Request. 2 UICC  T Response to Resume Time Request with the following parameters: - bMinResTime = '0A' to '1E'. - bMinSofTokens = 1 to 5. - bmRemWakeup = 0 or 1(Remote Wakeup Support Do not Care). RQ05_0301 RQ05_0302 RQ05_0303 3 T  UICC Suspend Device by maint...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6 Descriptors
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6.1 Standard-Descriptors
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6.1.1 Device Descriptor
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6.1.1.1 Test case 1: Device Descriptor Test
6.6.1.1.1.1 Test execution The test procedure shall be executed once for each of the following parameters: • There are no test case-specific parameters for this test case. 6.6.1.1.1.2 Initial conditions • Device in Default state 6.6.1.1.1.3 Test procedure Step Direction Description RQ 1 T  UICC Request the first 8 byt...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6.1.2 Configuration Descriptor with ICCD Interface
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6.1.2.1 Test case 1: Configuration Descriptor and ICCD Interface Descriptor Test
6.6.1.2.1.1 Test execution The test procedure shall be performed for each available configuration (as declared in clause 4.3) containing ICCD capability. Configurations are identified by index values. 6.6.1.2.1.2 Initial conditions • Device in Default state 6.6.1.2.1.3 Test procedure Step Direction Description RQ 1 T ...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6.1.3 Interface Descriptor
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6.1.3.1 Test case 1: EEM Interface Descriptor Test
6.6.1.3.1.1 Test execution The test procedure shall only be executed if EEM Interface is present. The test procedure shall be performed for each available configuration (as declared in clause 4.3) containing EEM capability. Configurations are identified by index values. 6.6.1.3.1.2 Initial conditions • Device in Defaul...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.6.1.3.2 Test case 2: Mass Storage Interface Descriptor Test
6.6.1.3.2.1 Test execution The test procedure shall only be executed if Mass Storage Interface is present. The test procedure shall be performed for each available configuration (as declared in clause 4.3) containing Mass Storage capability. Configurations are identified by index values. 6.6.1.3.2.2 Initial conditions ...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7 Protocol Stack and Higher Level
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.1 ICCD - APDU based UICC Applications
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.1.1 Test case 1: Suspend with no effect on internal State
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.1.1.1 Test execution
The test procedure shall be performed for each available configuration containing ICCD Control B interface (as declared in clause 4.3). Configurations are identified by index values.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.1.1.2 Initial conditions
• Device is at Device Address 42 and in Configured state. • The Resume time negotiation has been done. • ICC_POWER_ON sent.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.1.1.3 Test procedure
Step Direction Description RQ 1 T  UICC Send XFR_BLOCK with "SELECT MF" 2 UICC  T Return DATA_BLOCK containing expected response (SW = "90 00") RQ01_0203 3 T  UICC Send XFR_BLOCK with "SELECT EF" with parameter ICCID (ICC Identification/Identifier '2FE2') 4 UICC  T Return DATA_BLOCK containing expected response (SW...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.2 USB ICCD Control B
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.2.1 Test case 1: ICCD Control B Interface basic functionality
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.2.1.1 Test execution
The test procedure shall be performed for each available configuration (as declared in clause 4.3) containing ICCD capability. Configurations are identified by index values.
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.2.1.2 Initial conditions
• Device is at Device Address 42 and in Configured state. • ICCD Control B Configuration selected. • ATR has been received on ETSI TS 102 221 [2] interface, and recorded. ETSI ETSI TS 102 922-2 V7.1.0 (2025-10) 34 Release 7
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.2.1.3 Test procedure
Step Direction Description RQ 1 T  UICC Send ICC_POWER_OFF 2 T  UICC Send SLOT_STATUS request 3 UICC  T Return SLOT_STATUS (USB-ICC is virtually not present) RQ06_0101 4 T  UICC Send ICC_POWER_ON 5 T  UICC Send DATA_BLOCK request 6 UICC  T Return DATA_BLOCK containing valid ATR Verify that this ATR is identical t...
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.3 USB ICCD Bulk
cc725a86775f5379efd6316472d76bc0
102 922-2
6.7.3.1 Test case 1: ICCD Bulk Interface basic functionality