instruction stringlengths 29 35k | input stringclasses 1
value | output stringlengths 29 35k |
|---|---|---|
C1+ CV01 - Open phase faults during vehicle integration D2 -- Problem Description (R: PRE):
During Vehicle integration, open phase faults have been observed
Requirement which is violated (R: Originator):
Expected behavior (R: Originator):
Operating Environment (R: Originator):
Test case identification (... | C1+ CV01 - Open phase faults during vehicle integration D2 -- Problem Description (R: PRE):
During Vehicle integration, open phase faults have been observed
Requirement which is violated (R: Originator):
Expected behavior (R: Originator):
Operating Environment (R: Originator):
Test case identification (... | |
[Opel K0][Requirement] - Drop and replace SSM_PB related modules SWPM - SKO (21.07.21 - 13:47)
--------------------------------------------------------------------------------
Brief investigation comment:
After latest branch from VW it is identified that some of SSM_PB related modules need to be updated as shown below:... | [Opel K0][Requirement] - Drop and replace SSM_PB related modules SWPM - SKO (21.07.21 - 13:47)
--------------------------------------------------------------------------------
Brief investigation comment:
After latest branch from VW it is identified that some of SSM_PB related modules need to be updated as shown below:... | |
[0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering Preconditions / Ausgangsituation:
Vehicle: AERO / ID.Buzz054 / ID.Buzz089
SW SCS: M521 /b521
SW EBB: 657-002 / b651
Maneuver name: HBA
--------------------------------------------------------------------------------
Actions / Aktionen:
1... | [0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering Preconditions / Ausgangsituation:
Vehicle: AERO / ID.Buzz054 / ID.Buzz089
SW SCS: M521 /b521
SW EBB: 657-002 / b651
Maneuver name: HBA
--------------------------------------------------------------------------------
Actions / Aktionen:
1... | |
[0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering Preconditions / Ausgangsituation:
Vehicle: AERO / ID.Buzz054 / ID.Buzz089
SW SCS: M521 /b521
SW EBB: 657-002 / b651
Maneuver name: HBA
--------------------------------------------------------------------------------
Actions / Aktionen:
1... | [0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering Preconditions / Ausgangsituation:
Vehicle: AERO / ID.Buzz054 / ID.Buzz089
SW SCS: M521 /b521
SW EBB: 657-002 / b651
Maneuver name: HBA
--------------------------------------------------------------------------------
Actions / Aktionen:
1... | |
[0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering Preconditions / Ausgangsituation:
Vehicle: AERO / ID.Buzz054 / ID.Buzz089
SW SCS: M521 /b521
SW EBB: 657-002 / b651
Maneuver name: HBA
--------------------------------------------------------------------------------
Actions / Aktionen:
1... | [0521][CASE][VW_MEB41x_SCS]MCP oscillations cause HBA exit and HBA triggering Preconditions / Ausgangsituation:
Vehicle: AERO / ID.Buzz054 / ID.Buzz089
SW SCS: M521 /b521
SW EBB: 657-002 / b651
Maneuver name: HBA
--------------------------------------------------------------------------------
Actions / Aktionen:
1... | |
HKMC_SK PE | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code Activity Description:
With the outcome from W130j as Impact Analysis results on SWE1 per one clustered change from this release and one build, the change impacted features and behaviors identified and d... | HKMC_SK PE | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code Activity Description:
With the outcome from W130j as Impact Analysis results on SWE1 per one clustered change from this release and one build, the change impacted features and behaviors identified and d... | |
[Issue] of PBC_040 - SIL Test - Actuator change to Unknown at RAR and HostAvailability NONE/APPLY/RELEASE, before RAR or Parkapply Preconditions:Init with Fully released actuators. Close to Parkapplied, Set PbcIn.HostavailabilityRl/Rr/Both = None OR Relase OR Apply.
Action:Set Wheespeed to 3 km/h or perform a parkappl... | [Issue] of PBC_040 - SIL Test - Actuator change to Unknown at RAR and HostAvailability NONE/APPLY/RELEASE, before RAR or Parkapply Preconditions:Init with Fully released actuators. Close to Parkapplied, Set PbcIn.HostavailabilityRl/Rr/Both = None OR Relase OR Apply.
Action:Set Wheespeed to 3 km/h or perform a parkappl... | |
[Issue] of PBC_040 - SIL Test - Actuation stops even if actuation is possible due to change of Hostavailablity Preconditions: Init with Fully released actuators.
Action: Apply or Release, Set PbcInHostavailability to apply if acatuation is in apply direction or release if actuation is in release direction.
Expected ... | [Issue] of PBC_040 - SIL Test - Actuation stops even if actuation is possible due to change of Hostavailablity Preconditions: Init with Fully released actuators.
Action: Apply or Release, Set PbcInHostavailability to apply if acatuation is in apply direction or release if actuation is in release direction.
Expected ... | |
[Issue] of PBC_040 - SIL Test - RAR perform with speed >= 15 km/h Preconditions:Precondition for RAR
Action:Set all speeds >= 15 km/h
Expected Behaviour: No RAR perfomed
Actual behaviour: RAR is performed
Further Information/Requirements: This threshold of 15km/h is the limit of RAR,because of HSB Vehicle safety sp... | [Issue] of PBC_040 - SIL Test - RAR perform with speed >= 15 km/h Preconditions:Precondition for RAR
Action:Set all speeds >= 15 km/h
Expected Behaviour: No RAR perfomed
Actual behaviour: RAR is performed
Further Information/Requirements: This threshold of 15km/h is the limit of RAR,because of HSB Vehicle safety sp... | |
[Issue] of PBC_040 - SIL Test - PowerLatchRequest = ePbcPowerLatchNotRequested too early Preconditions: Init with Fully released actuators.
Action:Apply Release under several condition.
Expected Behaviour: PbcOut.EcuPowerLatchRequest = ePbcPowerLatchNotRequested two cycles after last PbcOut.MotorComamd = ePbcMotorCom... | [Issue] of PBC_040 - SIL Test - PowerLatchRequest = ePbcPowerLatchNotRequested too early Preconditions: Init with Fully released actuators.
Action:Apply Release under several condition.
Expected Behaviour: PbcOut.EcuPowerLatchRequest = ePbcPowerLatchNotRequested two cycles after last PbcOut.MotorComamd = ePbcMotorCom... | |
[Daimler_MMA_IBC] VX1000 connection setting in A2l shall be corrected When trying o connect CANApe with generated
DA31_P05_M10_S02_VT2_200_010_000_RTP.A2L, following error is occured.
Please analys and implment necessary Changes in A2l [26.08.2021, ScafesA]------------------------------------------------------------... | [Daimler_MMA_IBC] VX1000 connection setting in A2l shall be corrected When trying o connect CANApe with generated
DA31_P05_M10_S02_VT2_200_010_000_RTP.A2L, following error is occured.
Please analys and implment necessary Changes in A2l [26.08.2021, ScafesA]------------------------------------------------------------... | |
[VW KPM] [SV][BL][CAN] F1AB nach CheckMemory [Error Description]: VW80126.Gutfall (80126/VW80126.Gutfall):
FLASH_TEST_Gutfall
Kommentar Prüfer:
Es hat sich trotz CheckMemory keiner der Software Block Versionen aktualisiert.
[A: 80126-A119]
[A: 80126-A694]
Fehler-Beschreibung DANTE:
00000 (DIAG): Diagnose - RequestPDU... | [VW KPM] [SV][BL][CAN] F1AB nach CheckMemory [Error Description]: VW80126.Gutfall (80126/VW80126.Gutfall):
FLASH_TEST_Gutfall
Kommentar Prüfer:
Es hat sich trotz CheckMemory keiner der Software Block Versionen aktualisiert.
[A: 80126-A119]
[A: 80126-A694]
Fehler-Beschreibung DANTE:
00000 (DIAG): Diagnose - RequestPDU... | |
[VW KPM] [SV][PMode][CAN] PMode Parameter FF FF FF Perform an analysis for the issue below and suggest the next steps.
---------------------------------------------------------------------------------------------------------------------------
[Error Description]: Kontaktdaten:
E-Mail: VWAG R: WOB, EESN Sys-VQ
Bean... | [VW KPM] [SV][PMode][CAN] PMode Parameter FF FF FF Perform an analysis for the issue below and suggest the next steps.
---------------------------------------------------------------------------------------------------------------------------
[Error Description]: Kontaktdaten:
E-Mail: VWAG R: WOB, EESN Sys-VQ
Bean... | |
[Defect]: [Diag] ESP178: Session Handling-OTX - Check reprogramming precondition Not Implemented This CR shall be used to implement the following diagnostic jobs:
1. Check Reprogramming Preconditions - StartRoutine: $31 01 02 03 zz
2. PreCheckProgrammingDependencies - StartRoutine: $31 01 02 07 zz
Information:
- The ... | [Defect]: [Diag] ESP178: Session Handling-OTX - Check reprogramming precondition Not Implemented This CR shall be used to implement the following diagnostic jobs:
1. Check Reprogramming Preconditions - StartRoutine: $31 01 02 03 zz
2. PreCheckProgrammingDependencies - StartRoutine: $31 01 02 07 zz
Information:
- The ... | |
[Defect]: [Diag] ESP178: ID-Data services not implemented Aim (Objective and Rationale): Feature implementation of [DCRP 46.1] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16
Maturity Level: ML1 / Note Basic Technology Rollout Plan (BROP) - Milestone B1
As part of 'Work step: Perform ... | [Defect]: [Diag] ESP178: ID-Data services not implemented Aim (Objective and Rationale): Feature implementation of [DCRP 46.1] SF 8.8 System Diagnostic Function - Read ID-Data: Remaining jobs, Cluster ID 16
Maturity Level: ML1 / Note Basic Technology Rollout Plan (BROP) - Milestone B1
As part of 'Work step: Perform ... | |
[Defect]: [Diag] ESP178: ID-Data services not implemented Aim (Objective and Rationale): Feature implementation of [DCRP 46.1] SF 8.8 System Diagnostic Function - Read Version Data, Cluster ID 9
Maturity Level: ML1 / Note Basic Technology Rollout Plan (BROP) - Milestone B1
As part of 'Work step: Perform Preliminary ... | [Defect]: [Diag] ESP178: ID-Data services not implemented Aim (Objective and Rationale): Feature implementation of [DCRP 46.1] SF 8.8 System Diagnostic Function - Read Version Data, Cluster ID 9
Maturity Level: ML1 / Note Basic Technology Rollout Plan (BROP) - Milestone B1
As part of 'Work step: Perform Preliminary ... | |
[Defect]: [Diag] ESP178: ID-Data services not implemented This CR scope:
Integration of Crypto Stack + SSA for the functionally route of the SecOC jobs to Crypto SW
here the SecOC key generation has to be done using the default Car specific secret during the development phase (SSA-928)
Provision of initial (standar... | [Defect]: [Diag] ESP178: ID-Data services not implemented This CR scope:
Integration of Crypto Stack + SSA for the functionally route of the SecOC jobs to Crypto SW
here the SecOC key generation has to be done using the default Car specific secret during the development phase (SSA-928)
Provision of initial (standar... | |
[Defect]: [Diag] ESP178: ID-Data services not implemented The customer was informed that a functional implementation for the following read DIDs cannot be provided for SW B2 / X0200:
- 0xF18C „ECU SerialNumber"
- 0x010C „Vehicle Odometer“
- 0x0133 „Current Operating Time“
- 0xF103 „Vedoc relevant information“
Hence, t... | [Defect]: [Diag] ESP178: ID-Data services not implemented The customer was informed that a functional implementation for the following read DIDs cannot be provided for SW B2 / X0200:
- 0xF18C „ECU SerialNumber"
- 0x010C „Vehicle Odometer“
- 0x0133 „Current Operating Time“
- 0xF103 „Vedoc relevant information“
Hence, t... | |
[VW][MQB48W][ESC][X0401-010_X330] ESP_StartStopp_Info = Systemfehler Due to incorrect size of the ICC array "IccTxBuf_C1_C0.IsChassinfFunctionEnable_boolean" and the "for loop" shown below, Start/Stop function is always considered to be disabled by Chassinf (IsChassinfFunctionEnable(CHASSINF_SSA) always returns FALSE) ... | [VW][MQB48W][ESC][X0401-010_X330] ESP_StartStopp_Info = Systemfehler Due to incorrect size of the ICC array "IccTxBuf_C1_C0.IsChassinfFunctionEnable_boolean" and the "for loop" shown below, Start/Stop function is always considered to be disabled by Chassinf (IsChassinfFunctionEnable(CHASSINF_SSA) always returns FALSE) ... | |
Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC" Realization of Customer request: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC"
target is to provide the recent Parameterset (series software S011) in a new format for new Software S012:
CRs shall be create... | Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC" Realization of Customer request: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC"
target is to provide the recent Parameterset (series software S011) in a new format for new Software S012:
CRs shall be create... | |
Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC" Realization of Customer request: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC"
target is to provide the recent Parameterset in a new format:
CRs shall be created for following tasks
F&C:
*. update min... | Customer Request: parameter set in new format: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC" Realization of Customer request: BRSMLB51AB-1235: "Umsetzung UNECE Datensatzupdate PBC"
target is to provide the recent Parameterset in a new format:
CRs shall be created for following tasks
F&C:
*. update min... | |
[QRCM] GM T1XX - Motor Position Sensor (MPS) Failure to Learn "systematic root-cause" should be documented in 3x5 Why, and an improvement idea should be proposed.
This CR is to track the implementation of the systematic improvement Reject this CR for Preventive Action. SW can handle any specified range of error adjustm... | [QRCM] GM T1XX - Motor Position Sensor (MPS) Failure to Learn "systematic root-cause" should be documented in 3x5 Why, and an improvement idea should be proposed.
This CR is to track the implementation of the systematic improvement Reject this CR for Preventive Action. SW can handle any specified range of error adjustm... | |
[QA][PA2116][SYS.4][GP.2.1.2][GP.2.1.3][GP.2.1.4][SYS.5][GP.2.1.2][GP.2.1.3]Only Duration estimation mentioned in the MS project plan but not the effort (person days) Update MS Project information according to mentioned points. Update MS project information according to the weekness that ASPICE mentioned. | [QA][PA2116][SYS.4][GP.2.1.2][GP.2.1.3][GP.2.1.4][SYS.5][GP.2.1.2][GP.2.1.3]Only Duration estimation mentioned in the MS project plan but not the effort (person days) Update MS Project information according to mentioned points. Update MS project information according to the weekness that ASPICE mentioned. | |
Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs. Andrew Berg 07-21-21
Proposed_Changes_v2.zip attached.
QAC Report v2.zip attached.
Test Report v2.docx attached.
Andrew Berg 07-14-21
Propo... | Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs. Andrew Berg 07-21-21
Proposed_Changes_v2.zip attached.
QAC Report v2.zip attached.
Test Report v2.docx attached.
Andrew Berg 07-14-21
Propo... | |
Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults Below Fault IDs need to be removed from the DMT:
GROUND_1_DISCONNECTED
GROUND_2_DISCONNECTED See description | Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults Below Fault IDs need to be removed from the DMT:
GROUND_1_DISCONNECTED
GROUND_2_DISCONNECTED See description | |
Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults The goal of this CR to remove the following fault from the following programs:
A100 PBM, A100 SBM, 31XX:
GROUND_1_DISCONNECTED
GROUND_2_DISCONNECTED
The current plan for release is:
- September 7th for 31XX V05.0 Integ 2
- September 9th for A100 PBM V... | Integration OP A100/BEV3 PBM - Remove Ground Disconnected Faults The goal of this CR to remove the following fault from the following programs:
A100 PBM, A100 SBM, 31XX:
GROUND_1_DISCONNECTED
GROUND_2_DISCONNECTED
The current plan for release is:
- September 7th for 31XX V05.0 Integ 2
- September 9th for A100 PBM V... | |
Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs. Andrew Berg 07-21-21
Proposed_Changes_v2.zip attached.
QAC Report v2.zip attached.
Test Report v2.docx attached.
Andrew Berg 07-14-21
Propo... | Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults The goal of this CR is to disable/remove Ground monitor failsafes from A100 PBM, A100 SBM and 31XX.2 programs. Andrew Berg 07-21-21
Proposed_Changes_v2.zip attached.
QAC Report v2.zip attached.
Test Report v2.docx attached.
Andrew Berg 07-14-21
Propo... | |
Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults Below Fault IDs need to be removed from the DMT:
GROUND_1_DISCONNECTED
GROUND_2_DISCONNECTED following faults are removed from the DMT:
GROUND_1_DISCONNECTED
GROUND_2_DISCONNECTED | Integration OP A100/BEV3 SBM - Remove Ground Disconnected Faults Below Fault IDs need to be removed from the DMT:
GROUND_1_DISCONNECTED
GROUND_2_DISCONNECTED following faults are removed from the DMT:
GROUND_1_DISCONNECTED
GROUND_2_DISCONNECTED | |
[OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected SW-Resets due to exceptions in Opel-K0 project and below change was introduced with “ALM_Task 5202634: [OPEL K0] [PSW] Proivde interfaces for Tx signals” where the dataset are not aligned to group ID ordering of CAL sub groups. But a... | [OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected SW-Resets due to exceptions in Opel-K0 project and below change was introduced with “ALM_Task 5202634: [OPEL K0] [PSW] Proivde interfaces for Tx signals” where the dataset are not aligned to group ID ordering of CAL sub groups. But a... | |
[OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected 1) In X300_173 testing within Dry-HIL, UNEXPECTED_EXCEPTION failure was seen directly after switching the gearbox from D to P.
In further investigation it was found that it is caused due to alignment issue within Calibration Data as ... | [OPEL K0][X300_173][CAT2][ADTY3][TEC]: UNEXPECTED_EXCEPTION - fault is seen unexpected 1) In X300_173 testing within Dry-HIL, UNEXPECTED_EXCEPTION failure was seen directly after switching the gearbox from D to P.
In further investigation it was found that it is caused due to alignment issue within Calibration Data as ... | |
[xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM) - This CR is to track the improvement from 3x5Why “systemic leg”
Root cause: Data owner and memory stack service provider are not aligned. ?
Per Stephan Scheider, the process is mature for IBC Gen2 core projects, so called “NVRAM Contracts” in D... | [xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM) - This CR is to track the improvement from 3x5Why “systemic leg”
Root cause: Data owner and memory stack service provider are not aligned. ?
Per Stephan Scheider, the process is mature for IBC Gen2 core projects, so called “NVRAM Contracts” in D... | |
[xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM) - Improvement to detect identical failure in the plant is described in 3x5 Why.
"Modify EOL test to add power cycle..." EOL test was updated and verified.
This CR is created later to track the improvements via QRCM dashboard | [xxxxxxx] [NA] GM T1XX - MEC counter corrupted during EOL test (NVRAM) - Improvement to detect identical failure in the plant is described in 3x5 Why.
"Modify EOL test to add power cycle..." EOL test was updated and verified.
This CR is created later to track the improvements via QRCM dashboard | |
18A incorrect in ESLM data package nan One task for PXX team to implement the fix
2021-08-04 StolarsK:
Fix was implemented. CR can be closed. | 18A incorrect in ESLM data package nan One task for PXX team to implement the fix
2021-08-04 StolarsK:
Fix was implemented. CR can be closed. | |
[QA][WPA][PV03][S110-S120] System Baseline Work product to be released_ReAX Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned.
Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource).
It was note... | [QA][WPA][PV03][S110-S120] System Baseline Work product to be released_ReAX Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned.
Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource).
It was note... | |
[QA][WPA][S120][PV03] TSC needs an update with the changes to PV03 for ReAx project Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned.
Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource).
It ... | [QA][WPA][S120][PV03] TSC needs an update with the changes to PV03 for ReAx project Due to Resource constraints TSC and System Baseline updates could not be supported at the respective S Gates originally planned.
Agreed that these items should be re-planned to align with S200 (Depending allocation of Resource).
It ... | |
[Daimler MMA][SADM][PressSens] Move update filter function to 1 ms Task Please verify that the provided MCP values are now correct. CR will be shifted to 260_000 sw | [Daimler MMA][SADM][PressSens] Move update filter function to 1 ms Task Please verify that the provided MCP values are now correct. CR will be shifted to 260_000 sw | |
[Daimler MMA][SADM][PressSens] Move update filter function to 1 ms Task - In Daimler MMA, Pedal Travel sensor, Pressure sensor and BFL Sensor connected Via SENT need to sampled every 1ms, Currently sampled every 5 ms.
- It shall be discussed with Geelay as a base, Task scheduling need to adapted for SENT sensor to fit ... | [Daimler MMA][SADM][PressSens] Move update filter function to 1 ms Task - In Daimler MMA, Pedal Travel sensor, Pressure sensor and BFL Sensor connected Via SENT need to sampled every 1ms, Currently sampled every 5 ms.
- It shall be discussed with Geelay as a base, Task scheduling need to adapted for SENT sensor to fit ... | |
[Daimler MMA][SADM][PressSens] Move update filter function to 1 ms Task [Carsten Broehl (BroehlC), 29-06-2021 13:20]
------------------------------------------------------------------
On IBN Hil it was found that the pressure sensor signal contains wrong (to high) pressure values, while brake pedal is not applied.
De... | [Daimler MMA][SADM][PressSens] Move update filter function to 1 ms Task [Carsten Broehl (BroehlC), 29-06-2021 13:20]
------------------------------------------------------------------
On IBN Hil it was found that the pressure sensor signal contains wrong (to high) pressure values, while brake pedal is not applied.
De... | |
[Daimler MMA][SADM][PressSens] Move update filter function to 1 ms Task [Carsten Broehl (BroehlC), 16-07-2021 14:13]
------------------------------------------------------------------
Changes implemented with CR 5419359.
CR rejected
[Carsten Broehl (BroehlC), 29-06-2021 13:20]
----------------------------------------... | [Daimler MMA][SADM][PressSens] Move update filter function to 1 ms Task [Carsten Broehl (BroehlC), 16-07-2021 14:13]
------------------------------------------------------------------
Changes implemented with CR 5419359.
CR rejected
[Carsten Broehl (BroehlC), 29-06-2021 13:20]
----------------------------------------... | |
[Defect]: [Daimler][MMA][Issue]: CYS Issue Root & Backend CA Certificate Diagnostic service not working Pre: Precondition, Randbedingungen, z.B. Kl 15 ein, Außentemp.,... >
Platztest - ECU standalone
Diagnose via Monaco 9.02
Restbussimulation via CANoe 14.0: Kl.15=on, Ubat=12V, VIN=?????????????????, Odo=30km, v=0km/h... | [Defect]: [Daimler][MMA][Issue]: CYS Issue Root & Backend CA Certificate Diagnostic service not working Pre: Precondition, Randbedingungen, z.B. Kl 15 ein, Außentemp.,... >
Platztest - ECU standalone
Diagnose via Monaco 9.02
Restbussimulation via CANoe 14.0: Kl.15=on, Ubat=12V, VIN=?????????????????, Odo=30km, v=0km/h... | |
[Defect]: [Daimler][MMA][Issue]: CYS Issue RoutineControl Authenticate Diagnostic User or Tester Diagnostic service not working Pre: Precondition, Randbedingungen, z.B. Kl 15 ein, Außentemp.,... >
Platztest - ECU standalone
Diagnose via Monaco 9.02
Restbussimulation via CANoe 14.0: Kl.15=on, Ubat=12V, VIN=?????????????... | [Defect]: [Daimler][MMA][Issue]: CYS Issue RoutineControl Authenticate Diagnostic User or Tester Diagnostic service not working Pre: Precondition, Randbedingungen, z.B. Kl 15 ein, Außentemp.,... >
Platztest - ECU standalone
Diagnose via Monaco 9.02
Restbussimulation via CANoe 14.0: Kl.15=on, Ubat=12V, VIN=?????????????... | |
[Defect]: [Daimler][MMA][Issue]: CYS Issue Security event logging & DID 0x018F not working Please integrate HSM into application in order to support the security features defined in the parent OP
Customer requirements:
/P_DAI_MMA_IBC/10 External Specifications/Customer Specifications/MMA/c_Fachinhalte/Basisfunktionen/... | [Defect]: [Daimler][MMA][Issue]: CYS Issue Security event logging & DID 0x018F not working Please integrate HSM into application in order to support the security features defined in the parent OP
Customer requirements:
/P_DAI_MMA_IBC/10 External Specifications/Customer Specifications/MMA/c_Fachinhalte/Basisfunktionen/... | |
[Defect]: [Daimler][MMA][Issue]: CYS Issue Security event logging & DID 0x018F not working Please implement Feature: SW 1.2 Cyber-Security - B1.1
Customer Featurename:
Customer requirements:
/P_DAI_MMA_IBC/10 External Specifications/Customer Specifications/MMA/c_Fachinhalte/Basisfunktionen/Security/EBS_Security
DCR... | [Defect]: [Daimler][MMA][Issue]: CYS Issue Security event logging & DID 0x018F not working Please implement Feature: SW 1.2 Cyber-Security - B1.1
Customer Featurename:
Customer requirements:
/P_DAI_MMA_IBC/10 External Specifications/Customer Specifications/MMA/c_Fachinhalte/Basisfunktionen/Security/EBS_Security
DCR... | |
[Defect]: [Daimler][MMA][Issue]: CYS Issue Access Control List Version Information not working This CR shall be used:
1. to export a DEXT file for the X0260 diagnostic variant out of the CDD (Diag team)
2. to export the Ecu Individual ACL file for the X0260 diagnostic variant out of the CDD (Diag team)
3. to import the... | [Defect]: [Daimler][MMA][Issue]: CYS Issue Access Control List Version Information not working This CR shall be used:
1. to export a DEXT file for the X0260 diagnostic variant out of the CDD (Diag team)
2. to export the Ecu Individual ACL file for the X0260 diagnostic variant out of the CDD (Diag team)
3. to import the... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of Refspeed calculation at ONE PbcIn.WheelPressureReliability = ePbcWheelPressureNotReliable Precondition: Pbc Released, set PbcIn.WheelPressurereliabilityFL or FR or RL or RR = ePbcWheelPressureNotReliable and set one PbcIn.WheelPressurereliability after the other to ePbcW... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of Refspeed calculation at ONE PbcIn.WheelPressureReliability = ePbcWheelPressureNotReliable Precondition: Pbc Released, set PbcIn.WheelPressurereliabilityFL or FR or RL or RR = ePbcWheelPressureNotReliable and set one PbcIn.WheelPressurereliability after the other to ePbcW... | |
[657][CAT3][TEC] [VW_ID_Buzz_EBB] Speed_DCC functionality- SW Ratio and SW JUMPIN are not changing according to the vehicle speed as expected. The actual implementation only includes the vehicle speed dependency as described in VW_MQB_eBoosterAD_1692 & VW_MQB_eBoosterAD_1709. A continuous change of JumpIn or Ratio duri... | [657][CAT3][TEC] [VW_ID_Buzz_EBB] Speed_DCC functionality- SW Ratio and SW JUMPIN are not changing according to the vehicle speed as expected. The actual implementation only includes the vehicle speed dependency as described in VW_MQB_eBoosterAD_1692 & VW_MQB_eBoosterAD_1709. A continuous change of JumpIn or Ratio duri... | |
[657][CAT3][TEC] [VW_ID_Buzz_EBB] Speed_DCC functionality- SW Ratio and SW JUMPIN are not changing according to the vehicle speed as expected. The new cascade controller is required for winter testing in UN ECE software. Based on software X813 the BC update to a MQB48W X0404 baseline requires the following changes: 1) ... | [657][CAT3][TEC] [VW_ID_Buzz_EBB] Speed_DCC functionality- SW Ratio and SW JUMPIN are not changing according to the vehicle speed as expected. The new cascade controller is required for winter testing in UN ECE software. Based on software X813 the BC update to a MQB48W X0404 baseline requires the following changes: 1) ... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of maximum number of reclamps Precondition: RAR conditions with and without HPS
Action: Perform Rollaway reclamp with speed several times with and without HPS
Expected Behaviour:Only two reclamps allowed.
Actual Behaviour: MORE Reclamps are performed
Requirements:
EPBi... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of maximum number of reclamps Precondition: RAR conditions with and without HPS
Action: Perform Rollaway reclamp with speed several times with and without HPS
Expected Behaviour:Only two reclamps allowed.
Actual Behaviour: MORE Reclamps are performed
Requirements:
EPBi... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of Reclamp with Hostavailablity at Only release before RAR Precondition: RAR conditions
Action: Set PbcInHosavailabilityLeft Or Right = ePbcAvailabilityRelease, then perform RAR
Expected Behaviour: None defect side performs RAR
Actual Behaviour:Both side do not perform R... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of Reclamp with Hostavailablity at Only release before RAR Precondition: RAR conditions
Action: Set PbcInHosavailabilityLeft Or Right = ePbcAvailabilityRelease, then perform RAR
Expected Behaviour: None defect side performs RAR
Actual Behaviour:Both side do not perform R... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of Reclamp with Hostavailablity at Only release before RAR Precondition: RAR conditions
Action: Set PbcInHosavailabilityLeft Or Right = ePbcAvailabilityRelease, then perform RAR
Expected Behaviour: None defect side performs RAR
Actual Behaviour:Both side do not perform R... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of Reclamp with Hostavailablity at Only release before RAR Precondition: RAR conditions
Action: Set PbcInHosavailabilityLeft Or Right = ePbcAvailabilityRelease, then perform RAR
Expected Behaviour: None defect side performs RAR
Actual Behaviour:Both side do not perform R... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of ParkSupportRequest at HTR Precondition: Set precondition for HTR at 500 Deg.
Action: Call PbcCyclic until the first HTR step
Expected Behaviour: PbcOut.ParkSupportRequest = ePbcParkSupportRequested for 2 PbcCyclic
Actual Behaviour: PbcOut.ParkSupportRequest = ePbcPark... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of ParkSupportRequest at HTR Precondition: Set precondition for HTR at 500 Deg.
Action: Call PbcCyclic until the first HTR step
Expected Behaviour: PbcOut.ParkSupportRequest = ePbcParkSupportRequested for 2 PbcCyclic
Actual Behaviour: PbcOut.ParkSupportRequest = ePbcPark... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of ParkSupportRequest at HTR CR to update SwRS according to finding of CR 5846407:
"The system requirement EPBi-Audi-PPE-SyDesign_1650 related to the software requirement EPBi_Audi_PPE-SwRS_2342 is rejected.
Hence the software requirement should also be rejected."
Descr... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of ParkSupportRequest at HTR CR to update SwRS according to finding of CR 5846407:
"The system requirement EPBi-Audi-PPE-SyDesign_1650 related to the software requirement EPBi_Audi_PPE-SwRS_2342 is rejected.
Hence the software requirement should also be rejected."
Descr... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of ParkSupportRequest at HTR Precondition: Set precondition for HTR at 500 Deg.
Action: Call PbcCyclic until the first HTR step
Expected Behaviour: PbcOut.ParkSupportRequest = ePbcParkSupportRequested for 2 PbcCyclic
Actual Behaviour: PbcOut.ParkSupportRequest = ePbcPark... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of ParkSupportRequest at HTR Precondition: Set precondition for HTR at 500 Deg.
Action: Call PbcCyclic until the first HTR step
Expected Behaviour: PbcOut.ParkSupportRequest = ePbcParkSupportRequested for 2 PbcCyclic
Actual Behaviour: PbcOut.ParkSupportRequest = ePbcPark... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of ParkSupportRequest at negetive PbcIn.LongAcceleration Precondition: Set precondition for ParkSupportRequest with negative PbcIn.LongAcceleration
Action: Set PbcInApplyReleaseRequest = ePbcApplyReleaseRequestParkApply for 2 cycles
Expected Behaviour: PbcOut.ParkSupportR... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of ParkSupportRequest at negetive PbcIn.LongAcceleration Precondition: Set precondition for ParkSupportRequest with negative PbcIn.LongAcceleration
Action: Set PbcInApplyReleaseRequest = ePbcApplyReleaseRequestParkApply for 2 cycles
Expected Behaviour: PbcOut.ParkSupportR... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of Recalmp with HPS/HPO Acknowledge too late (> 2s) Precondition: Set HPO conditions.
Action: Set PbcInApplyReleaseRequest = ePbcApplyReleaseRequestParkApply for 2 cycles set PbcInHpsAcknowledge >= 2 s after Hps request
Expected Behaviour: After 2s a reclamp shall be perf... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of Recalmp with HPS/HPO Acknowledge too late (> 2s) Precondition: Set HPO conditions.
Action: Set PbcInApplyReleaseRequest = ePbcApplyReleaseRequestParkApply for 2 cycles set PbcInHpsAcknowledge >= 2 s after Hps request
Expected Behaviour: After 2s a reclamp shall be perf... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of HPO request at 11V and Release direction Precondition: Set Pbc is Parkapplied, Set MotorSupplyVoltage and MotorVoltageLeft and Right to 11V
Action: perform release he PBC
Expected Behaviour: No HPO request is requested
Actual Behaviour: Pbc requests HPO
Requirements:... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of HPO request at 11V and Release direction Precondition: Set Pbc is Parkapplied, Set MotorSupplyVoltage and MotorVoltageLeft and Right to 11V
Action: perform release he PBC
Expected Behaviour: No HPO request is requested
Actual Behaviour: Pbc requests HPO
Requirements:... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of EVENT_VARIANT_CODE_INVALID is not working Precondition: Set PbcIn.VariantItem[0] = 255
Action: Call PbcInit, then PbcCyclic
Expected Behavior: PbcOut.FaultStatus[17] = ePbcFaultStateFailed
Actual Behaviour: PbcOut.FaultStatus[17] = ePbcFaultStateNotSupported
Require... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of EVENT_VARIANT_CODE_INVALID is not working Precondition: Set PbcIn.VariantItem[0] = 255
Action: Call PbcInit, then PbcCyclic
Expected Behavior: PbcOut.FaultStatus[17] = ePbcFaultStateFailed
Actual Behaviour: PbcOut.FaultStatus[17] = ePbcFaultStateNotSupported
Require... | |
[Issue] of PBC_X01_501_00p - SiL Test - Issue of EVENT_VARIANT_CODE_INVALID is not working Precondition: Set PbcIn.VariantItem[0] = 255
Action: Call PbcInit, then PbcCyclic
Expected Behavior: PbcOut.FaultStatus[17] = ePbcFaultStateFailed
Actual Behaviour: PbcOut.FaultStatus[17] = ePbcFaultStateNotSupported
Require... | [Issue] of PBC_X01_501_00p - SiL Test - Issue of EVENT_VARIANT_CODE_INVALID is not working Precondition: Set PbcIn.VariantItem[0] = 255
Action: Call PbcInit, then PbcCyclic
Expected Behavior: PbcOut.FaultStatus[17] = ePbcFaultStateFailed
Actual Behaviour: PbcOut.FaultStatus[17] = ePbcFaultStateNotSupported
Require... | |
[Issue] of PBC_X01_501_00p - SiL Test -Issue of Out Of Spec Message C with not acknowledged ParkSupportRequest Precondition: PbcOut.ActuatorState_RL/RR = ePbcActuatorStateReleased PSR request condtions
Action: PbcInApplyReleaseRequest = ePbcApplyReleaseRequestParkApply for 2 cycles. PbcIn.ParkSupportAck not Acknowled... | [Issue] of PBC_X01_501_00p - SiL Test -Issue of Out Of Spec Message C with not acknowledged ParkSupportRequest Precondition: PbcOut.ActuatorState_RL/RR = ePbcActuatorStateReleased PSR request condtions
Action: PbcInApplyReleaseRequest = ePbcApplyReleaseRequestParkApply for 2 cycles. PbcIn.ParkSupportAck not Acknowled... | |
[Issue]of PBC_X01_501_00p - SiL Test - Issue of EVENT_ACTUATOR_POSITION_INCOHERENT,Park Apply operation is not performing after fault recovery Precondition:Set PbcOut.ActuatorState_RL= ePbcActuatorStateReleased, PbcOut.ActuatorState_RR = ePbcActuatorStateParkapplied VIA Diag operation,Then set FaultStatus[10]=ePbcFau... | [Issue]of PBC_X01_501_00p - SiL Test - Issue of EVENT_ACTUATOR_POSITION_INCOHERENT,Park Apply operation is not performing after fault recovery Precondition:Set PbcOut.ActuatorState_RL= ePbcActuatorStateReleased, PbcOut.ActuatorState_RR = ePbcActuatorStateParkapplied VIA Diag operation,Then set FaultStatus[10]=ePbcFau... | |
[Issue]of PBC_X01_501_00p - SiL Test - Issue of EVENT_ACTUATOR_STATE_UNKNOWN,Park Apply is not performing on Good side Actuator Precondition:intially PbcOut.ActuatorState_RL= ePbcActuatorStateUnknown, PbcOut.ActuatorState_RR = ePbcActuatorStateReleased,FaultStatus[11]=ePbcFaultStateFailed
Action: set ApplyReleaseReq... | [Issue]of PBC_X01_501_00p - SiL Test - Issue of EVENT_ACTUATOR_STATE_UNKNOWN,Park Apply is not performing on Good side Actuator Precondition:intially PbcOut.ActuatorState_RL= ePbcActuatorStateUnknown, PbcOut.ActuatorState_RR = ePbcActuatorStateReleased,FaultStatus[11]=ePbcFaultStateFailed
Action: set ApplyReleaseReq... | |
[X400-002][CAT2][TCS][VW_UNECE_EBB][Mesweerte] Mil status ON is not updating when read data by identifier driver warning displays (0x4E01) is requested in Supported sessions Kindly perform retest for related issue.
For issue details and analysis results kindly refer open point description and conclusion field.
Documen... | [X400-002][CAT2][TCS][VW_UNECE_EBB][Mesweerte] Mil status ON is not updating when read data by identifier driver warning displays (0x4E01) is requested in Supported sessions Kindly perform retest for related issue.
For issue details and analysis results kindly refer open point description and conclusion field.
Documen... | |
Issue of PBC not reacting to HoldApply Requests Please review the attached trace for the issue described below. Expected behavior must be honored by PBC.
Scenario 1 (Trace: HoldAppy_Issue.zip)
Preconditions: Brake module in fallback mode (ESF), vehicle in dynamic state, EPB actuator state is released.
Action: Driver ... | Issue of PBC not reacting to HoldApply Requests Please review the attached trace for the issue described below. Expected behavior must be honored by PBC.
Scenario 1 (Trace: HoldAppy_Issue.zip)
Preconditions: Brake module in fallback mode (ESF), vehicle in dynamic state, EPB actuator state is released.
Action: Driver ... | |
[BSW_Test]:[1.121]:Issue with vehicle speed signals update with Hard reset Issue: Vehicle speed signal values are not changing aftera Hard reset
Procedure:
1_S: Provide a vehicle speed by updating Throttle.
2_S: Request the wakeup condition (A Hard Reset - 11 01)
3_V: Verify the Vehicle speeds (LongitudinalVehicleS... | [BSW_Test]:[1.121]:Issue with vehicle speed signals update with Hard reset Issue: Vehicle speed signal values are not changing aftera Hard reset
Procedure:
1_S: Provide a vehicle speed by updating Throttle.
2_S: Request the wakeup condition (A Hard Reset - 11 01)
3_V: Verify the Vehicle speeds (LongitudinalVehicleS... | |
[BSW_Test]:[1.121]:Issue with wheel speed signal update with usage mode states Issue: Usage mode signal "VehModMngtGlbSafe1UsgModSts" not getting updated to the states 11, 13
Procedure:
1_S: Set the signal "VehModMngtGlbSafe1UsgModSts" values to 0,1,11,13
2_V: Verify the Vehicle speeds (LongitudinalVehicleSpeed' (Ve... | [BSW_Test]:[1.121]:Issue with wheel speed signal update with usage mode states Issue: Usage mode signal "VehModMngtGlbSafe1UsgModSts" not getting updated to the states 11, 13
Procedure:
1_S: Set the signal "VehModMngtGlbSafe1UsgModSts" values to 0,1,11,13
2_V: Verify the Vehicle speeds (LongitudinalVehicleSpeed' (Ve... | |
[X400-002][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Detection time for MSG_GETRIEBE_11_CRC fault. Kindly perform retest for related issue.
For issue details and analysis results kindly refer open point description and conclusion field.
Document the test results in OP conclusion field and set the custom pick field 3... | [X400-002][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Detection time for MSG_GETRIEBE_11_CRC fault. Kindly perform retest for related issue.
For issue details and analysis results kindly refer open point description and conclusion field.
Document the test results in OP conclusion field and set the custom pick field 3... | |
[X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. 1) General
Please collect all required Fault Monitors and Input Validations and create a task for SiSo team.
Please review latest SiSo changes.
Please check, whether the FSM has to be updated.
2) See attachm... | [X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. 1) General
Please collect all required Fault Monitors and Input Validations and create a task for SiSo team.
Please review latest SiSo changes.
Please check, whether the FSM has to be updated.
2) See attachm... | |
[X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. 1) General
Please collect all required Fault Monitors and Input Validations and create a task for SiSo team.
Please review latest SiSo changes.
Please check, whether the FSM has to be updated.
GordonR1, 10.0... | [X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. 1) General
Please collect all required Fault Monitors and Input Validations and create a task for SiSo team.
Please review latest SiSo changes.
Please check, whether the FSM has to be updated.
GordonR1, 10.0... | |
[X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. This CR shall be used to create an actual Baseline in Doors and generate source code for EBB Sw X0403
Please create a task for System OBD Team to provide the DOORS SISO Baselines TRAND (2022.02.16):
--------... | [X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. This CR shall be used to create an actual Baseline in Doors and generate source code for EBB Sw X0403
Please create a task for System OBD Team to provide the DOORS SISO Baselines TRAND (2022.02.16):
--------... | |
[X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. 1) General
Please collect all required Fault Monitors and Input Validations and create a task for SiSo team.
Please review latest SiSo changes.
Please check, whether the FSM has to be updated.
2) See attachm... | [X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. 1) General
Please collect all required Fault Monitors and Input Validations and create a task for SiSo team.
Please review latest SiSo changes.
Please check, whether the FSM has to be updated.
2) See attachm... | |
[X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. 1) Implement all necessary Failsafe changes in Comms code for this Build after SiSo-Freeze, as requested by spawned by SiSo CR .
2) Please rename the following monitors:
-a) ..
3) Please update the (weight... | [X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. 1) Implement all necessary Failsafe changes in Comms code for this Build after SiSo-Freeze, as requested by spawned by SiSo CR .
2) Please rename the following monitors:
-a) ..
3) Please update the (weight... | |
[X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. Kindly perform retest for related issue.
For issue details and analysis results kindly refer open point description and conclusion field.
Document the test results in OP conclusion field and set the custom pic... | [X400-001][CAT2][TCS][VW_UNECE_EBB][COMMS]: Issue with Fault Passing time for few CAN Communication Faults. Kindly perform retest for related issue.
For issue details and analysis results kindly refer open point description and conclusion field.
Document the test results in OP conclusion field and set the custom pic... | |
[Issue][ITC][MIL][StateHandler] - PostrunTimer is incrementing by 2 per sample when ExtBrReq or NmKeepAliveRequired signals are active Problempath:
BC/BC_SWCs/BcMain/Subsystem/BcMain/BcMain_LibBlock/BcMain_MediumCyclic/InitShSmcArb/StateHandler/EbbStateDetermination/Postrun_Action/PhaseA_FullBoost
Build version: BC_G... | [Issue][ITC][MIL][StateHandler] - PostrunTimer is incrementing by 2 per sample when ExtBrReq or NmKeepAliveRequired signals are active Problempath:
BC/BC_SWCs/BcMain/Subsystem/BcMain/BcMain_LibBlock/BcMain_MediumCyclic/InitShSmcArb/StateHandler/EbbStateDetermination/Postrun_Action/PhaseA_FullBoost
Build version: BC_G... | |
PR58364 Jeep Compass ARM calibration update for EMEA variants ARM calibration update driven by customer request to have more sensitive activation and longer pressure duration for the control. [02.07.2021, K.Kampa]: Parameter updates are reasonable. | PR58364 Jeep Compass ARM calibration update for EMEA variants ARM calibration update driven by customer request to have more sensitive activation and longer pressure duration for the control. [02.07.2021, K.Kampa]: Parameter updates are reasonable. | |
[FCA_WS][SFIT]: For Few faults FSM is in "AGREED" state, Variables related to faultstatus are not found in elf. This CR is used to Plan/Monitor the SWE 1 work for "Manage Vehicle Interface" feature Summary
This CR will be used to update SWE.1 module: "GenC Software Requirements Manage Vehicle Interface" for MY23 A... | [FCA_WS][SFIT]: For Few faults FSM is in "AGREED" state, Variables related to faultstatus are not found in elf. This CR is used to Plan/Monitor the SWE 1 work for "Manage Vehicle Interface" feature Summary
This CR will be used to update SWE.1 module: "GenC Software Requirements Manage Vehicle Interface" for MY23 A... | |
[FCA_WS][SFIT]: For Few faults FSM is in "AGREED" state, Variables related to faultstatus are not found in elf. D2 -- Problem Description (R: PRE):
For below faults, FSM is in "AGREED" state, Variables related to faultstatus are not found in elf.
DEM_PU_BD_L1_FET_B1_OC_FAULT
DEM_PU_BD_L1_FET_B1_SC_FAULT
DEM_PU_BD_L1_... | [FCA_WS][SFIT]: For Few faults FSM is in "AGREED" state, Variables related to faultstatus are not found in elf. D2 -- Problem Description (R: PRE):
For below faults, FSM is in "AGREED" state, Variables related to faultstatus are not found in elf.
DEM_PU_BD_L1_FET_B1_OC_FAULT
DEM_PU_BD_L1_FET_B1_SC_FAULT
DEM_PU_BD_L1_... | |
[DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please tailor and Link the Feature:
SF 7.6 Efficency support
Ensure traceability and consistency.
Customer Featurename:
BRS_StartStopp_Schnittstelle
LAH reference:
for customer requirements, see information from Power BI:
https://app.powerbi.com/group... | [DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please tailor and Link the Feature:
SF 7.6 Efficency support
Ensure traceability and consistency.
Customer Featurename:
BRS_StartStopp_Schnittstelle
LAH reference:
for customer requirements, see information from Power BI:
https://app.powerbi.com/group... | |
[DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please create SysRS and SysAD for following System Feature:
SF 7.6 Efficency support Holger Schmidt - PSM - (08.09.2021):
--------------------------------------------------------------------------------
Closed after Review. All linked Work Items / Tasks complete... | [DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please create SysRS and SysAD for following System Feature:
SF 7.6 Efficency support Holger Schmidt - PSM - (08.09.2021):
--------------------------------------------------------------------------------
Closed after Review. All linked Work Items / Tasks complete... | |
[DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please initiate SYS.4 test activity for Feature:
SF 7.6 Efficency support
Customer Featurename:
BRS_StartStopp_Schnittstelle
SysAD reference:
/DOORS-9_Koblenz/03 Customer Projects/VW/P_VW_MQB_48W/30 System/ESC/04 System Architecture/SyDesign
http://skobde-door... | [DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please initiate SYS.4 test activity for Feature:
SF 7.6 Efficency support
Customer Featurename:
BRS_StartStopp_Schnittstelle
SysAD reference:
/DOORS-9_Koblenz/03 Customer Projects/VW/P_VW_MQB_48W/30 System/ESC/04 System Architecture/SyDesign
http://skobde-door... | |
[DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please initiate SYS.5 test activity for Feature:
SF 7.6 Efficency support
Customer Featurename:
BRS_StartStopp_Schnittstelle
SyRs reference:
http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230... | [DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please initiate SYS.5 test activity for Feature:
SF 7.6 Efficency support
Customer Featurename:
BRS_StartStopp_Schnittstelle
SyRs reference:
http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230... | |
[DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please initiate SYS.5 test activity for Feature:
SF 7.6 Efficency support
Customer Featurename:
BRS_StartStopp_Schnittstelle
SyRs reference:
http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230... | [DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please initiate SYS.5 test activity for Feature:
SF 7.6 Efficency support
Customer Featurename:
BRS_StartStopp_Schnittstelle
SyRs reference:
http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230... | |
[DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please initiate SYS.5 test activity for Feature:
SF 7.6 Efficency support
Customer Featurename:
BRS_StartStopp_Schnittstelle
SyRs reference:
http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230... | [DCRP 07.07.06][ESC] Linking: SF 7.6 Efficiency support Please initiate SYS.5 test activity for Feature:
SF 7.6 Efficency support
Customer Featurename:
BRS_StartStopp_Schnittstelle
SyRs reference:
http://skobde-doors9wa.ad.trw.com:8080/dwa/rm/urn:rational:e9aba799-bc96-11e5-b6b9-419012b199da:1-479f06bc41562230... | |
PRTS 2149023 - EBCM , Flash/KP - EOLT - Flash - EBCM MAC Authentication Failures with Random Keys Please plan thic change implemented for 08/17/2021 release.
*. 0xE2 : Update EBCM “SUM_SSC_KeyMapping” configuration to move 0xE2 from SSC_Key_Slot_10 to SSC_Key_Slot_11
*. 0x26C: Update EBCM SSC MSG_MAC_STATUS Calib... | PRTS 2149023 - EBCM , Flash/KP - EOLT - Flash - EBCM MAC Authentication Failures with Random Keys Please plan thic change implemented for 08/17/2021 release.
*. 0xE2 : Update EBCM “SUM_SSC_KeyMapping” configuration to move 0xE2 from SSC_Key_Slot_10 to SSC_Key_Slot_11
*. 0x26C: Update EBCM SSC MSG_MAC_STATUS Calib... | |
[Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | [Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | |
[Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | [Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | |
[Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | [Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | |
[Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | [Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | |
[Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | [Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [27.07.2021 - 10:16]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold, HillAssist is active
Actions:
1. Driver is pressing the ... | |
[Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver Follow up CR of CR 5582554
As the vehicle type of the Opel K0 is a van, the payload can reach high values over 1000 kg which results in a high hold pressure, as the full payload is used for the vehicle weight calc... | [Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver Follow up CR of CR 5582554
As the vehicle type of the Opel K0 is a van, the payload can reach high values over 1000 kg which results in a high hold pressure, as the full payload is used for the vehicle weight calc... | |
[Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver Implement clutch interface to allow a comfortable drive off with from active Hill Assist [Martin Bienert (bienertm), 02.03.2022, 14:18:57]
Implement the clutch interface to allow a comfortable drive off without roll... | [Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver Implement clutch interface to allow a comfortable drive off with from active Hill Assist [Martin Bienert (bienertm), 02.03.2022, 14:18:57]
Implement the clutch interface to allow a comfortable drive off without roll... | |
[Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [15.03.2022 - 10:34]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold via brakepressure on a gradient uphill
----------------------... | [Opel K0][300_177][CAT3][ADBY4.3] Vehicle Test -HillAssist is isolating pressure in case of HA maneuver ADBY4.3 - MarxT [15.03.2022 - 10:34]:
--------------------------------------------------------------------------------
Preconditions:
Vehicle is hold via brakepressure on a gradient uphill
----------------------... | |
Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | ANGLE_SENSOR_A1_FAULT and ANGLE_SENSOR_A2_FAULT raise when NARROW XCHECK FAULTis raised, which is not expected Please update test cases according to conclusion in the action linked to the OP. test case update done acc. to task 5949867
test case executed in task 5915305 | Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | ANGLE_SENSOR_A1_FAULT and ANGLE_SENSOR_A2_FAULT raise when NARROW XCHECK FAULTis raised, which is not expected Please update test cases according to conclusion in the action linked to the OP. test case update done acc. to task 5949867
test case executed in task 5915305 | |
Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | After inserting Angle WIDE/NARROW fault, System raises fault which is not assigned to Ducato project in FSM Test Case to be udpated according to action. Bugfix confirmation done in task 8432864. - issue no longer observed.
For more details see task 8432864
ALM_Open Point... | Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | After inserting Angle WIDE/NARROW fault, System raises fault which is not assigned to Ducato project in FSM Test Case to be udpated according to action. Bugfix confirmation done in task 8432864. - issue no longer observed.
For more details see task 8432864
ALM_Open Point... | |
Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | After inserting Angle WIDE/NARROW fault, System raises fault which is not assigned to Ducato project in FSM See issue description in linked OP 5790327 One task for PFS team
2022-08-05 STOLARSK:
Please update FSM according to the proposed changes in ALM_Action 5662796 ... | Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | After inserting Angle WIDE/NARROW fault, System raises fault which is not assigned to Ducato project in FSM See issue description in linked OP 5790327 One task for PFS team
2022-08-05 STOLARSK:
Please update FSM according to the proposed changes in ALM_Action 5662796 ... | |
Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | After inserting Angle WIDE/NARROW fault, System raises fault which is not assigned to Ducato project in FSM FSM has been updated accordingly. Please check the FSM and if necessary retest with FA with updated test case Bugfix confirmation done in task 8432864. - issue no l... | Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | After inserting Angle WIDE/NARROW fault, System raises fault which is not assigned to Ducato project in FSM FSM has been updated accordingly. Please check the FSM and if necessary retest with FA with updated test case Bugfix confirmation done in task 8432864. - issue no l... | |
Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | After inserting Angle WIDE/NARROW fault, System raises fault which is not assigned to Ducato project in FSM Summary description of problem:
Sample: Based on FSM baseline 290.1 Angle faults which are applicable for FCA Ducato project:
However DEMs which raised... | Fiat_Ducato_BD | SYS.4 + SYS.5 | TAS FIT DA00 | After inserting Angle WIDE/NARROW fault, System raises fault which is not assigned to Ducato project in FSM Summary description of problem:
Sample: Based on FSM baseline 290.1 Angle faults which are applicable for FCA Ducato project:
However DEMs which raised... | |
GWM_B30_DP | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code Activities Description:
1. Perform Change Analysis Handling per SW Release and one Build and Clustered Input Changes (Aligned Cluster with System):
?
1.2 Perform Detail Impact Analysis
Based on initial... | GWM_B30_DP | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code Activities Description:
1. Perform Change Analysis Handling per SW Release and one Build and Clustered Input Changes (Aligned Cluster with System):
?
1.2 Perform Detail Impact Analysis
Based on initial... | |
GWM_B30_DP | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code Activities Description:
1. Perform Change Analysis Handling per SW Release and one Build and Clustered Input Changes (Aligned Cluster with System):
?
1.2 Perform Detail Impact Analysis
Based on initial... | GWM_B30_DP | FA00 | SWE5 | DTC&MIL Mapping Test - DTC&MIL mapping fails or inconsistencies between FSM and the code Activities Description:
1. Perform Change Analysis Handling per SW Release and one Build and Clustered Input Changes (Aligned Cluster with System):
?
1.2 Perform Detail Impact Analysis
Based on initial... | |
Fault Detecting Data - PRESS_SENS_1_COMM_FAULT/ PRESS_SENS_2_COMM_FAULT The missing fast message fault counts up on occasion on good parts causing FMM data to show that the fault is counting up. The reason is that the software expects data at 1 ms rate, and the sensor sends data at 0.99 ms rate. Also, the clocks of the... | Fault Detecting Data - PRESS_SENS_1_COMM_FAULT/ PRESS_SENS_2_COMM_FAULT The missing fast message fault counts up on occasion on good parts causing FMM data to show that the fault is counting up. The reason is that the software expects data at 1 ms rate, and the sensor sends data at 0.99 ms rate. Also, the clocks of the... | |
Fault Detecting Data - MICRO_CLOCK_PLAUSIBILITY_FAILURE This OP will be closed out once the system has been updated to filter out counts as requested in the one pager. Design approach for filtering out count is not agreed on | Fault Detecting Data - MICRO_CLOCK_PLAUSIBILITY_FAILURE This OP will be closed out once the system has been updated to filter out counts as requested in the one pager. Design approach for filtering out count is not agreed on |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.