In this case you could ask yourself whether or not less accurate assembly procedures would be acceptable. Presumably that would reduce assembly costs, and there’s no economic sense in keeping the range of anticipated results under tighter control than required by the joint.Such results might also indicate excessive ove...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
456
8e90ef12-0f07-4198-b12e-01cf91099dea
in some cases, the accuracy of our rough estimates can be quite good. This accuracy, of course, will depend on the accuracy with which we estimate the scatter of the individual key variables. Sometimes an experiment can be made to refine our guess for one or a couple of the number of variables you pin down this way, th...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
456
cbdb74e6-1db0-4e5f-8f80-d73befd695b7
17.5 WHICH VARIABLES TO INCLUDE IN THE ANALYSIS 17.5.1 I NGENERAL Which variables should we include when making an analysis of this sort to pick preload or torque for an existing joint? The answer to this question will obviously have a major impact onBickford/Introduction to the Design and Behavior of Bolted Joints 817...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
456
5c9c1fd7-eacf-405a-9ba5-c2f8d7400a2e
the results we get, and the answer depends upon what it is we are trying to do. Why are we trying to pick preload or torque or other control variables for this particular joint? Picking preload ora torque is something the designer should have done—if a particular value is important. If we’redoing it, it can only be bec...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
457
a714d6b8-6e02-43f3-ac20-df360e8b1252
Magnitude of the external loadStiffness ratio (‘‘load factor’’)Eccentricity, if presentEmbedmentBending stress in the bolts Tool scatter (e.g., torque-to-preload variations) The effect of torsional stress on the tensile stress capacity of the boltThe fatigue endurance limit of the boltsThe bearing stresses between nut ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
457
13bccb10-af6c-46aa-9d7a-200c6fec7f61
17.5.3 W HICHSHOULD WEINCLUDE ? Almost all of these factors are present and influe nce results when we tighten a group of bolts. Only differential expansion, gasket cr eep, hole interference, and the weig ht effect are application specific and may be absent. And we won’t care about the f atigue endurance limit if the a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
457
184d75f3-64b0-47f0-8f85-84b8d8d07a59
(and often operator problems), a re essentially always there. I fs o — w h yl e a v ea n yo ft h e mo u t ? One big reason most of these factors have always been left out is that we have been generally unaware that they exist. Another reason: even if we know they exist we have hadlittle or no data with which to support...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
457
f2239286-cd62-46f6-bc70-046124b6a2f6
one thickness of a given material tested only at room temperature. In this book I’ve included whatever further data I could find on other variables, but, considering the number ofvariables involved in bolting, the data will often not apply to your application.Bickford/Introduction to the Design and Behavior of Bolted J...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
457
e938b858-317f-460b-a895-0d2a24ba029d
How can we leave them out and still design or assemble most joints successfully? Easy: we have traditionally overdesigned bolted joints—and included healthy ‘‘safety factors’’—to cover our ignorance. The overdesign gives us room to include the factors now, whenever wewant a clearer understanding of why a joint has caus...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
458
9e4d5849-14e1-41a0-8994-0658109d00e2
Even though we’ll usually include factors the designer overlooked, or use different assumptions than he did about things like the stiffness ratio and the magnitude of externalloads, it’s still useful to make the analysis described earlier—or the more rigorous one to bedescribed in Section 17.7. Either analysis is relat...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
458
4a9d8185-5d79-45e6-a837-6e11e97ea692
suggest root causes for a troublesome problem. But don’t overdo it. Start by including only the three or four factors you believe will have the most impact on the behavior of your joint, based on previous experience withthat joint whenever possible. Include a safety factor or tolerance to cover uncertainties.Revise you...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
458
187a850e-b788-47c4-b3ae-ce615a0f00e0
17.6 ASTM F16.96 SUBCOMMITTEE ON BOLTING TECHNOLOGY I have a final suggestion for those of your who are frustrated by the fact that bolted jointassembly is still dominated by uncertainty, trial-and-error, and chance; and by the fact thatmost standards organizations have ignored this. Slow but steady progress has been m...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
458
31df2a75-4997-4dd2-8753-6336c8d6c94e
but very little progress has been made in assembly technology. As a result a group of us, representing nearly 100 organizations, formed the Bolting Technology Council (BTC), whichwas for many years sponsored by the Materials Properties Council, then of New York(current Ohio address in Appendix C). The goal of the BTC w...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
458
93b31f40-26a1-4ea6-91b4-c19bdc220404
this important effort should contact the ASTM (see also Appendix C). 17.7 A MORE RIGOROUS PROCEDURE The procedure we’ve looked at is very useful for making seat-of-the-pants decisions about preload and other matters, using our best guess about which factors might mostinfluence the results—and our guesses about the poss...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
458
69c0ff07-8e1e-4e70-a154-727b83ddd345
to make final decisions on safety-related or critical joints, I think that the procedure is valid for most situations. 17.7.1 E XPERIMENTS REQUIRED FOR TRUEACCURACY When truly accurate answers are required, we’d have to make carefully controlled experi-ments on the actual joint. Finite-element analysis might help, but ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
459
ce1274e0-d1d4-4882-a232-491bbcfc644e
We could use Equations 11.21 through 11.23 to utilize the experimentally collected data. Those equations are repeated below, with some examples, for your convenience. 17.7.2 T HEEQUATIONS Whether or not we have experimental data with which to make our analysis, we will often wanta more rigorous way to analyze the possi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
459
4ca85899-86eb-41a3-b54a-2d212bbd9835
earlier. Maximum bolt load (extending Equation 10.15): MaxF B¼(1þs)FPa/C0DFm/C0DFEIþFenLX/C6FenK00 J(DLJ/C0DLB)( 11:21) Minimum per-bolt clamping force on the joint (extending Equation 10.16): MinFJ¼(1/C0s)FPa/C0DFm/C0DFEI/C0(1/C0Fen)LX/C6FenK00 J(DLJ/C0DLB)( 11:22) Total minimum clamping force on a joint containing Nb...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
459
ff1211e4-0791-45c3-bb56-d5672c273c56
EI¼eEIFPa eEI¼the percentage of average, initial preload ( FPa) lost as a result of elastic interactions, expressed as a decimal DLB¼the change in length of the grip length portion of a loose bolt created by a changeofDt(8F,8C) in temperature (in., mm); see Equation 11.14Bickford/Introduction to the Design and Behavior...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
459
9e8620ad-e825-4afe-a84a-787d82af98ae
DLJ¼the change in thickness of the joint members, before assembly, if exposed to the same Dt(in., mm); see Equation 10.15 s¼half the anticipated scatter in preload during assembly, expressed as a decimalfraction of the average preload; see Equation 10.1 K 00 J¼the stiffness of a joint in which both the axes of the bolt...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
460
f43498a9-aad6-4c3f-8759-d1952343fd26
Again, these equations can be rewritten using any appropriate combination of FandKJ. 17.7.3 M INIMUM CLAMPING FORCE—S OMEEXAMPLES 17.7.3.1 First Example—Using Worst-Case Values Let’s feed these equations some numbers to see how important it is to use the best available numbers. Let’s start with Equation 11.22 and compu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
460
6ff71055-b1f2-4e95-9dff-e4881a38c2d7
tells us that the average loss would be 30% if a sheet gasket were included in the joint, or46% if the gasket is a spiral wound type (see Section 10.1.2). External load effect: the tensile load reduced the per-bolt clamping force on the joint by 269 lbs, based on the assumption that the external load was equal to 25% o...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
460
6bf7b46c-c2ec-4c70-b647-adf7eddc964c
tions that Inconel bolts were being used in a mild steel joint and that the operatingtemperature would be 400 8F. These assumptions give us the results shown in Figure 17.9, a minimum, per-bolt clamping force on the joint of 123 lbs. The ratio between average initial preload and resi-dual clamping force is about 12:1. ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
460
25bc9218-f5bf-4408-8186-c63658331d99
It purports to define the minimum tension we can expect to see in some of the bolts. To do that, however, we would have to assume a worst-case elastic interaction loss of 36% instead ofan average 18%. I tried that—and computed a residual, minimum, per-bolt clamping force ofBickford/Introduction to the Design and Behavi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
460
8312cd44-1b82-4334-9387-43074b9778e9
minus 135 lbs. Since my goal was to teach you how to use Equation 11.22, not to define and analyze an actual example, I used 18%. But it means that the computed 123 lbs is an ‘‘almost worst case’’ answer. Equation 11.23 says that we can compute the minimum anticipated clamping force on a joint containing Nbolts by mult...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
461
0bf7bb5c-38eb-4745-9777-f06c1c053849
In the quick-and-dirty procedure we discussed earlier in this chapter, we used the square root of the sum of the squares of the variances to reduce the combined effect of tool scatter, embedment, and elastic interactions, to get a more cheerful—and more realistic—picture. This introduces the assumption that no one bolt...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
461
678b9448-3b64-441a-a414-5caf53ee6c8c
02004006008001000120014001600Remaining per-bolt clamp (lb) FPa Scatter Embed Elast int Load Diff exp FPrFactors affecting clamping force FIGURE 17.9 Chart showing the large difference expected between the average, initial, per-bolt clamp- ing force applied to a joint during assembly ( FPa) and the residual, in-service ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
461
6da49294-25b1-4716-81b3-ab4df8232504
47.9% of average assembly preload (from which we further subtract the load and differential losses). The resulting per-bolt clamping force is now 268 lbs, more than twice what it was under our earlier assumptions. The preload-to-residual-clamp ratio is about 5:1, not some- thing to celebrate, but a definite improvement...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
462
52509588-6bc3-450d-836b-ec98f8ff2343
Could we resolve this by feeding only average data into Equation 11.22? That would suggest the following: Tool scatter: 0% average loss! Embedment: 5% average Interaction loss: 18% average Load and differential expansion losses unchanged These assumptions would result in a big improvement in predicted clamping force, t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
462
0673d360-6526-4cfb-aa8c-26ff6914044f
tool scatter.02004006008001000120014001600Remaining per-bolt clamp (lb) FPa Scatter Embed Elast int Load Diff exp FPrFactors affecting clamping force FIGURE 17.10 Chart showing the anticipated difference between initial and residual clamping force when we assume that worst-case effects will never (or rarely) occur simu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
462
022f46a6-9ef1-4819-b219-f8f65343c72c
The results are shown in Figure 17.11, an average worst-case (if there is such a thing) per- bolt, in-service, clamping force of 495 lbs, and a preload-to-clamp-force ratio of only 2.9:1. I would feel comfortable multiplying this number by Nto estimate the total force on the joint. To repeat, however, every answer we g...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
463
b99c4add-9383-43f5-852c-6496323ee805
clamping force of only 1.8 to 1. Since the load effect and differential expansion losses can be accurately predicted if we know joint materials and geometry—and, the tough part, the magnitude of the loads we will see in service—this would also eliminate the need for joint experiments. The feedback gives us the experime...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
463
4d7fdac3-fed5-4a46-962a-eacdf2da1f13
We have focused this more rigorous discussion entirely on the use of Equations 11.22 and 11.23. We should never accept the assembly preloads suggested by use of these equations without also using Equation 11.21 to estimate the worst-case stresses our choice would create in some of the bolts. These were calculated, corr...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
463
babeb837-64f1-4740-8b36-207566816ff7
view of the results than those shown in Figures 17.9 and 17.10, especially if our goal is to compute the total clamping force applied to the joint by Nbolts. See the text for a detailed discussion.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C017 Final Proof page 417 26.7.2007 6:00pm Composito...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
463
f95f8e6a-4396-435d-8cbf-6652161178d4
and we don’t multiply the results by Nor something. Even here, however, our inputs to the equation can distort the results and penalize our design. If we’re planning to use torque is it reasonable to assume a worst-case þ30% scatter, for example, or will that be reduced when we lubricate the bolts? Regardless of which ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
464
465393f2-5d9a-4a81-b902-7bc74cf83638
priate assembly control variable. They’ve also given us a chance to review many of the topics we’ve considered in this book. 17.8 NASA’S SPACE SHUTTLE PRELOAD SELECTION PROCEDURE Selecting correct preload is always important when joint safety is involved: when failure of the joint would lead to loss of life or serious ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
464
4420d4b7-b72c-4768-b7db-8058bc2fb8e5
preloads created during assembly. 1. The first uses modifications of the prevailing torque versions of the long-form or short-form, torque–preload equations (Equations 7.3 and 7.5). These are solved by02004006008001000120014001600Remaining per-bolt clamp (lb) FPa Assy res Load Diff exp FPrFactors affecting clamping for...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
464
3123db34-4142-47ef-ac10-1124105a272f
inputting typical friction coefficients or nut factors. These typical values must be those obtained from prior experience or, presumably, technical reports, involving the samematerials, surface finishes, and lubricants. Uncertainties are compensated for by toolscatter factors. Unlike the equations in Chapter 7, the NAS...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
465
0f6fba01-1e92-4c20-a84c-efb5a91f2dfb
P¼thread pitch (in.) mt¼coefficient of friction between male and female threads rt¼effective radius of thread forces (in.) a¼thread lead angle (for UN threads tan/C01¼[1=(pnE)] b¼thread half angle E¼basic pitch diameter of external threads mn¼coefficient of friction between nut face or bolt head and joint member Re¼eff...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
465
2037e7d4-45ce-4441-ac30-469c133cf2e6
Torque measurement of cad-plated bolts +30% Torque measurement of lubricated bolts +25% Hydraulic tensioner +15% Preload indicating washers +10% Ultrasonic measurement device +10% Bolt elongation measurement +5% Instrumented bolts +5% Source : From ‘‘Criteria for Preloaded Bolts,’’ NASA Space Shuttle Program Document N...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
465
ac262ec4-8b84-4ffd-8341-1fbdc7aa8375
FPmin¼(1/C0s)(Tmin/C0TP)=KDþFneg th/C0Fem (17:9) where K¼the nut factor D¼nominal diameter of the bolt NASA says that the embedment loss can be 5% of FPmaxif this is a metal-to-metal joint. The embedment loss of preload in gasketed joints or joints involving nonmetals must be determined by an application-specific test....
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
466
fb82208b-c883-420e-98d6-9665980c2869
equations. 3. In the third recognized procedure maximum and minimum preloads are measured after tightening a group of bolts to yield, in an application-specific joint. 4. In the fourth and final recognized procedure preload is controlled by means of a torque wrench or tightening the bolts to yield. Now the designer mus...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
466
7ea59b97-487d-454b-b188-e5616be19e9b
tool scatter factor, plus differential expansion and embedment factors, as in thisexample: F Pmin¼(1/C0s)(FP/C0TOL)þFneg th/C0Fem (17:10) 17.8.2 C ONFIRMING THE PRELOAD CALCULATIONS The NASA procedure does not end with the calculations of maximum and minimum preloads.The designer must now consider the impact of shear a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
466
93e7f6ad-86d5-44f5-8130-ca4713c6591c
and under minimum anticipated preload conditions. He must also consider fatigue loading and fracture criteria. 17.8.3 D ISCUSSION This NASA procedure covers all of the variables and uncertainties described earlier in thischapter, which is reassuring. But it all starts, mysteriously, by picking a torque and then usingth...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
466
16c3b492-0309-4c1e-b38b-e8f180067cf4
the designer first defines an acceptable assembly clamping force (and therefore desired pre- loads). He then worries about the effects of service conditions and loads on the clampingforce before finalizing his selection of assembly preload. Only after that does he decide howmuch torque, or other control parameters, sho...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
466
a5a82907-7ea9-44dd-8c03-3aea869df9f0
EXERCISES 1. Name at least four factors which can reduce in-service clamping force. 2. Name at least three factors which can be prevented or at least reduced by sufficient in-service clamping force. 3. Name at least four factors which determine the allowable upper limit of the in-service clamping force. 4. At approxima...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
467
944eb593-58ec-439a-b2fe-bb7900327265
9. When estimating bolt tension as in Figure 17.4 why do we go to the trouble of using the square root of the sum of the squares? Why not just add the error variables arithmetically? 10. What would be the cumulative scatter of the four variables we used in the Figures 17.2 through 17.7 if we combined them arithmeticall...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
467
72395390-95d2-4510-bab9-53a96a475f7e
Connection Workshop in Safety Harbor, Florida, February 06–07, 2002. 2. ‘‘Criteria for Preloaded Bolts,’’ NASA Space Shuttle Program Document NSTS 08307, Revision A, Lyndon Johnson Space Flight Center, Houston, Texas, July 6, 1998. 3. Novak, G.J. and T. Patel, Thread lubricants, Handbook of Bolts and Bolted Joints , J....
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
467
3fb6b10a-19ce-4648-9ca3-e3ca48810015
Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C017 Final Proof page 422 26.7.2007 6:00pm Compositor Name: BMani
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
468
afe39903-3e40-4aa5-bc70-a3b88a85d7e4
18Design of Joints Loaded in Tension This is the first of two chapters on the design of bolted joints. In this first chapter we are going to discuss, in general, the design of joints loaded in tension, first examining a typicalprocedure, then the more rigorous, VDI procedure. Then, in Chapter 19, we’ll take a brieflook...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
469
976a8aeb-cb9f-4e41-869b-5022106aeb10
the integrity or reliability of the clamp, the stability of the clamp in service, and the life of theclamp. The specific factors a given designer must consider will depend, of course, on the application of his particular joint. Designers of joints for nuclear power plants or aircraftwill obviously have to consider many...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
469
4bfe86c4-fc88-4bc8-a217-ee300556114f
can mean many different things, I think that the following checklist will be a useful place to start our summary of the design process. It tabulates the main issues which determinereliability. Few applications will involve all of the points listed here, but each topic is avalid concern somewhere. When you start a new d...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
469
33bb82ad-1b1a-4671-b736-587f6a2ca387
to prevent slip, separation, vibration, misalignment, wear, etc. of the interconnectedparts of the product or system ii. Enough boltsBickford/Introduction to the Design and Behavior of Bolted Joints 8176_C018 Final Proof page 423 26.7.2007 1:55pm Compositor Name: VAmoudavally 423
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
469
7cf79ea2-ab7b-4494-8fe0-50606e4a7e3a
iii. Adequate bolt diameter iv. Appropriate material strength v. Sturdy joint members 3. A joint (clamp) which is also stable under service conditions, i.e., won’t degrade or weaken. (Factors such as corrosion, vibration, fatigue, and elevated temperatures can change the clamp.) Stability requires the things tabulated ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
470
93b78d9d-ed70-41c0-a81f-92cb7162e439
5. Bolt and joint geometry (shape which encourages stability of the clamp): i. Properly designed to minimize stress concentrations (e.g., bolt head-to-shank fillets and thread run-out details which reduce the chances of fatigue failure; anotherexample—joint shear planes which coincide with thread run-out encourage fail...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
470
e81a8ef4-b605-4469-b1b7-199c9224fb46
service loads and =or thermal effects.) 7. Enough clamp: i. Clamping force must be high enough to minimize self-loosening of the bolts under vibration, thermal cycles, joint flexing, etc. ii. It must be high enough to minimize load changes in the bolts (thereby improving fatigue life). iii. It must be high enough to pr...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
470
2999af70-3a96-43fd-81c5-9ca187959820
unexpected loads or thermal effects. ii. Clamping force must be low enough to avoid damaging or distorting joint mem- bers (e.g., excessive flange rotation). iii. Clamping force must be low enough to avoid crushing a gasket (which can also cause leakage). 18.2 TYPICAL DESIGN STEPS The checklist above helps us set our s...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
470
acb8c03f-ec38-4d20-bcf6-7dfd5764bb89
Most bolted joints in this world probably are, and will continue to be, designed by gut feel based on past experience with similar joints. This is perfectly acceptable. A complete design analysis can be very expensive, thanks to the large number of variables and factors involved.Analysis is usually justified if one is ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
470
9f204aef-ee97-4291-94d2-c5dba54e180c
Even with critical joints, past experience will be involved and pertinent, of course, again because of the large number of variables and the inevitable uncertainty in each which will always make the outcome less than certain. No matter what the specific application for a bolted joint, certain common design steps will u...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
471
4c88ecc1-0178-4234-9493-abe6d98b02d3
defining such things as operating speed, temperature, desired life, estimated cost targets, etc. 18.2.2 P RELIMINARY DESIGN Preliminary geometric layouts are usually next. These roughly define the size and shape of the various parts involved, including the joint members. 18.2.3 L OADESTIMATES Once we know how big this ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
471
11bf22be-d95e-4102-8df8-357d2ab870a9
rotation etc.—compare to combined service loads Estimate chances of achieving desired range of clamp during assembly Accept design or repeat one or more of the earlier steps above FIGURE 18.1 Block diagram that summarizes the activities involved in the design of bolted joints.Bickford/Introduction to the Design and Beh...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
471
b67b1764-01c0-4fdd-ad29-2583b2603162
joints, this is an oft-neglected step, but for a good reason. It’s often very difficult to estimate service loads. If you’re serious about the analytical design of bolted joints, however, you can’tignore this step. As far as the joints are concerned, these loads will presumably include such things as weight, inertial a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
472
dcabedcf-5e94-42a7-8739-76d341a1c3d2
18.2.4 R EVIEW PRELIMINARY LAYOUTS :DEFINE THE BOLTS The load estimates will, of course, affect the size and shape of parts, and vice versa. In fact, inmost situations, the geometric layout and load-estimating steps will be performed simultane-ously. In any event, with approximate joint geometry and loads established, ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
472
f614a24c-1a03-4142-a583-fc499a24a96f
It’s also useful, when selecting the bolts, to estimate their static strength to set an upper bound on the stress or tension which they can support. We will rarely design the joint toimpose such stresses on the bolt, but it is useful to define this upper limit. At this point, thedesigner should also estimate the stripp...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
472
90fd93ac-11f0-4461-ad6a-1c5a8112f7f5
18.2.5 C LAMPING FORCE REQUIRED 18.2.5.1 Minimum Clamp We have now roughed out the joint configuration, picked the bolts, and estimated the maximum tensile strength (and, therefore, clamping force) available from these bolts. Ournext step (which many designers will place first!) is to estimate the minimum amount ofclam...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
472
850b251f-dfc3-494f-9c43-d650a1a182ca
as the joint diagram and assume that the bolts will see any external tensile load in its entirety. The amount by which the assembly and in-service clamping forces selected by the designer should exceed the external load will depend on such things as the accuracy with which the boltsare to be tightened, the accuracy wit...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
472
db6a77b3-1ce9-4e0e-824c-a2a8948b0fae
which cause most joints to be overdesigned—heavier than they need to be to compensate for assembly uncertainties. As an example, many people want the nominal clamping force to bethree to four times the anticipated service loads.Bickford/Introduction to the Design and Behavior of Bolted Joints 8176_C018 Final Proof page...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
472
8e276e31-dc37-4163-b8b4-a0e3fbac7c86
In critical situations, the designer must carefully estimate the service loads on the joint and the required resistance to those loads when selecting a clamping force. The goal, of course, is to eliminate any chance of bolted joint failure. The analysis, therefore, can bedefined in terms of failure modes, as follows. T...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
473
8ac2d155-0062-4fde-a3b8-863509cb8538
clamping force. We must also satisfy ourselves that the joint—and especially the bolts—are never exposed to too much stress. As we saw in the last chapter, the clamping force is usually limited by a bolt strength factor; including the bolt’s fatigue strength, thread-strippingstrength, or susceptibility to stress corros...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
473
302ddac1-61d9-4463-ab7c-e9b92ac88089
18.3 JOINT DESIGN IN THE REAL WORLD Figure 18.1 implies that joint design is a well-organized, step-by-step logical procedure. It canbe and it has been reduced to this by codified procedures in several industries. But, in mostsituations, I suspect it’s governed more by impulse and intuition than logic. The designerstar...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
473
914c043c-96b4-42b6-871b-eb2c91207446
Design is, after all, a creative process, and too many rules can be counterproductive.The complex technology of the bolted joint, however, makes rules, shopping lists, guide- lines, etc. often helpful and sometimes essential. If the joint is important the several topicslisted in Figure 18.1 should be addressed by the d...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
473
79163faa-55b6-488f-91aa-000279c2ff5e
to use the procedure published some years ago by the German engineering society VDI. This is the most detailed, publicly available, general-purpose, joint design procedure I’ve encoun-tered. We first used a version of it in Chapters 10 and 11 when we were studying the behaviorof a joint under tensile loads. We returned...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
473
3dbe801f-c861-4c7c-999e-b9638a4d858e
18.4 VDI JOINT DESIGN PROCEDURE I’m basing the following discussion primarily on the G.H. Junker paper [1] listed in thereferences at the end of this chapter. Although my copy isn’t dated, I know that this paperpredates the first edition of this book, and therefore is probably about 25 years old. The VDIprocedure was f...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
473
d4c046b4-d6d4-4e1c-8178-bc850fe160e9
18.4.1 T ERMS AND UNITS We’ll use the following terms and units while following the VDI procedure: AP ¼contact area between bolt head, or nut face, and the joint (in.2,m m2). Ar ¼root diameter area of the threads (in.2,m m2); see Table 3.3. AS ¼tensile stress area of the threads (in.2,m m2); see Appendix F. FB ¼tension...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
474
42d542f3-aeae-45e9-b198-26b9d5aa1a2a
eccentrically loaded joint (lb, N). FP ¼preload in general (lb, N). DFP ¼loss of preload during or immediately following assembly because of embedmentand elastic interaction effects (lb, N). MaxF P¼maximum anticipated per-bolt preload during assembly (lb, N). MinFP¼minimum anticipated per-bolt preload during assembly (...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
474
b3f7d962-5e60-44d7-9336-fef8aaf18026
MinF J¼minimum bolt preload and clamping force created during assembly, before thejoint is put in service (lb, N). F y ¼the tensile force required to yield the bolt (lb, N). K0 J ¼stiffness of a concentric joint loaded at internal loading planes (lb =in., N =mm). DLB¼increase or decrease in the grip length section of t...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
474
86085015-ecaa-466a-ba48-ad95bbeaf0c4
head or nut without damaging the joint; Pa is usually a little greater than theyield strength of the joint material (psi, MPa). R G ¼radius of gyration of the joint (in., mm). a,s,u¼important dimensions of an eccentrically loaded joint, illustrated in Figure 11.12(in., mm). s ¼scatter in preload caused by the assembly ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
474
d6f2d3d9-f0c4-4839-ba97-4b4ad715b078
aA¼the scatter in preload caused by the assembly tools and procedures as defined by VDI. aA¼Max FP=Min FP. If we use a +30% torquing procedure, aA¼ 1.30=0.70¼1.86. See Table 18.1 for other VDI values. FKn¼load factor for a concentric joint, loaded internally at loading planes. FKn¼ DFB=LX. m¼coefficient of friction bet...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
475
89f09a64-6ea3-497a-b936-16e4eb301778
We’ll assume that we have roughed out the configuration and size of this joint and its bolts, starting basically as we did in the procedure described in Section 18.2. We have also estimated the type and magnitude of the external loads to be placed on this joint; and have decided howmuch clamping force will be required ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
475
bec2fdf5-fbc9-4ac2-9d5e-b1ba0a53ae38
aI computed these values using the data tabulated in Figure 7 of Ref. [5] and shown in the next column. I believe that the Ref. [5] numbers are based on Table 17 of Ref. [2] (which is in German). bVDI, influenced by Junker and SPS, say that yield control is nearly perfect: that any scatter will be caused only by variat...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
475
cb708401-90fc-4c91-af53-372e1d836e9f
1. We’ll make a preliminary estimate of the assembly preload requirements, taking things like tool scatter and relaxation effects into account. We’ll assume that preload equals the per-bolt clamping force, too (i.e., no hole interference or weight effect). 2. Then we’ll revise our estimate of the assembly preload requi...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
476
ebfb0711-e80b-4a93-9bc1-d52e8bc52124
neither the bolts nor joint members are overstressed. We’ll do all this to determine .Maximum tension seen by some bolts .Minimum clamp force seen by some joints .Specifications for the optimum bolt for this joint 18.4.4 E STIMATING ASSEMBLY PRELOADS :PRELIMINARY ESTIMATE OF MINIMUM ANDMAXIMUM ASSEMBLY PRELOADS VDI say...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
476
2a24ae32-1c78-46a1-adfe-d659ffe90c2c
TheDF Pterm gives us our first problem, or rather, our first need for some engineering judgment. VDI equates DFPto embedment relaxation, but we now know that elastic inter- actions will also be present and can cause far more loss than will embedment. In my opinion,therefore, we should start by including these interacti...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
476
efa62534-d08c-4785-ab2c-69d953fb7e62
430 Introduction to the Design and Behavior of Bolted Joints
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
476
615b37ca-73c0-4039-948e-51ac22bad3ce
create on the joint. Things like hole interference and weight effect, in other words, are ignored (as they should be for most joints). 18.4.5 A DDING THE EFFECTS OF THE EXTERNAL LOAD We have not yet fully defined the max and min preloads we want to create during assembly,because we haven’t taken another important clamp...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
477
145cd063-609c-4d75-97f5-d0336f77986d
The joint must be able to function, in service, with the minimum clamping force which remains in the joint after relaxation and external load effects have done their worst. I’m going to follow the VDI procedure and call this remaining clamping force the ‘‘force that’srequired’’ to prevent the joint from misbehaving or ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
477
7dea4006-bdf7-491c-a2d4-e5a814c21c3a
MinF¼DF JþFPrqdþDFP (18:5) and MaxFJ¼aADFJþFPrqdþDFP/C2/C3 (18:6a) We can rewrite that last expression in terms of the external load or MaxFJ¼aA1/C0FKn ðÞ LXþFPrqdþDFP/C2/C3 (18:6b) Now, VDI says that we can use Equation 18.6 to size the bolts. They do this by using therelationship MaxF J<0:9Fy (18:7) Why 0.9 Fy? VDI a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
477
7c2d9222-474a-48e0-9304-1a6c361d1c22
to or expect to introduce at assembly, before the external load is actually applied. They are,therefore, still equal and opposite to the preloads created when we tighten the bolts. The Max F JBickford/Introduction to the Design and Behavior of Bolted Joints 8176_C018 Final Proof page 431 26.7.2007 1:55pm Compositor Nam...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
477
a95c4fcf-0ffe-4600-a258-943984f131ea
does not define the maximum tension the bolts will see when actually placed in service. We’ll get to that in Equation 18.9. 18.4.6 I S THE REQUIRED FORCE GOODENOUGH ? At the beginning of this design procedure we defined the failure modes we fear, and the minimum clamping force we think will be required to prevent them....
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
478
628710e9-7980-4334-b1e6-c6d971a1eebc
Separation : The residual clamping force, FPrqdmust be greater than zero, and the more greater the better! Limited by the forces =stresses the parts can stand. Transverse slip : FPrqd>FS=m (18:8) Leakage :FPrqdmust be large enough to create the residual gasket stress currently defined by the ASME Code’s mfactor—or the ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
478
49789e87-44dc-4c86-846b-3d0f3f5d447d
(1/C0FKn)LX, leaving a residual clamping force called the ‘‘force required to combat joint failure,’’ FPreq. The minimum required assembly preload, Min FJ, is the sum of FPreqplus the two loss effects. The maximum assembly preload is aAtimes that. The target preload, FPa, to be used to compute an assembly torque lies h...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
478
b5a58dd6-6337-4c82-ad6e-5d6c1587e230
Fatigue: Clamp load FPrqdmust be as large as possible—presumably limited by how much force or stress the parts can stand. If this is an eccentric joint, subjected to cyclic loads, FPrqdwill be replaced by FKrdas discussed under Section 18.4.7.6 below. This ends Mr. Junker’s list of possible clamp force requirements. We...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
479
f988dd21-a653-4ffa-a50b-afc37ac62005
have to compensate by retightening the bolts after creep has occurred. Nevertheless, it’s a factor we mustn’t forget. Differential thermal expansion : A change in temperature can cause a simultaneous increase or decrease in bolt tension and clamping force. If a decrease is indicated we’ll want toadd a term covering tha...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
479
b2f581a2-6635-489a-b80e-680067563baf
18.4.7.1 Static Strength of the Bolt We don’t want the stress in the bolts to exceed their yield strength, so: MaxF B¼MaxFJþDFB<Fy (18:9a) or MaxFR¼MaxFJþFKnLX/C20Fy (18:9b) These equations define the true, maximum, in-service tension the bolts will see. VDI says that another way of expressing this is by the following ...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
479
694626e3-1f8d-4ad7-89c2-92f3e7384458
DFB=2¼FKnLX=2/C20sAAr (18:11) We could, of course, substitute a specific fatigue life stress for the endurance limit stress if something less than infinite life were acceptable for the application. If the load cycles between LXand an LXminwhich is greater than zero, then FKnLX/C0LXmin ðÞ =2/C20sAAr (18:12) Or, for a pu...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
480
861019e7-a9d1-4495-b2d2-1ce1da2300bd
VDI says that the bearing stress under the head of the bolt or between nut and joint should not exceed the boundary surface pressure of the joint material, or 0:9MaxF J/C20PGAP (18:14) where PG¼boundary surface pressure (psi, MPa) and is usually slightly higher than the yieldstrength of the joint material A P¼contact a...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
480
77617132-5227-4f42-8cca-36fec9621638
Figure 12.10. Now we must compare Max FBnot to the yield strength of the bolt, but to remaining tensile capacity of the bolt. 18.4.7.5 Bending Stress In critical situations we might want to estimate any bending stresses to be seen by the bolt; perhaps using the VDI expression given in Equation 11.8. Tensile or combined...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
480
7154fa2c-cb96-436f-ae26-0786fb9b760e
FKrqd¼(a/C0s)u=RG2þsu/C0/C1 (18:15) There are potential problems here. We’re told that acan be statically indeterminate in some joints (e.g., for an automotive conrod) [3] and that sandRGare not easy to quantify [1]. See Figure 11.12 for an illustration defining a,s, andu. If the eccentric joint is subjected to cyclica...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
481
7b7cb732-6e13-4f56-a37c-afa90f140af8
change in fiber stress and use that change instead of DFBin Equation 18.11. 18.4.8 R EVISED BOLTSPECIFICATIONS At the beginning of this design procedure we tentatively selected a bolt size and material. Theanalysis which followed was intended to confirm or refute that choice. VDI tells us that wecan now use Equations 1...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
481
dc1f4ace-6fcd-4b90-a7cc-d0dbcae5f828
procedure to be used) 6. The joint stiffness ratio or load factor, with a consideration of how the joint is going to be loaded (internally or externally; eccentrically or concentrically) 7. The amount of bolt strength which will be absorbed by torsional stress 8. The clamping force required to prevent slip, separation,...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
481
62072244-feb9-4802-b636-0abcdac260b5
18.5 AN EXAMPLE Let’s try an example to see how we might use the VDI equations. 18.5.1 I NPUTS We must first decide whether we want to assign maximum, minimum, or average values to the various design parameters, in effect facing the same decisions we dealt with in Section 17.7.3.My preference at that time was for avera...
d:\Zotero\sync\storage\ZHFGBDWY\Bickford和Faulkner - 1995 - An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded 97.pdf
481